Document rx3bVo3abJZyGjzEkgwOOejNv
*Y
/
J
I -I
H
A
Gary Draper - Aberdeen
s
Robert L. Lembke, M.D. - Ponca City, Oklahoma
4 -I *
*P
. .June 23, 1978
*
*
i
ANNUAL MEDICAL/INDUSTRIAL HYGIENE INSPECTION - ABERDEEN CHEMICAL PLANT
As you know, during June 12-14, 1978, Dr- Oran Steffey. Industrial Hygienist,
Medical Division, made an industrial hygiene inspection of your chemical plant. Dr. Steffey was. accompanied by J. R. Drumwright, M.D., Assistant Medical Director. Attached for your information is a copy of Dr. Steffey's report to me covering that inspection. Dr. Steffey's findings and
*_
recommendations are self-explanatory.
b'
It is noted that Dr. Stef fey found the Aberdeen Chemical Plant to be in very good shape and you and your plant personnel are to be commended for the progress which is being made to provide a safe and healthful work place.
We appreciate the hospitality shown Drs Steffey and Drumwright during
their visit to yOur facilities.
J-T*
i
r y^
Robert L Lembke, M.D
Medical Director
T.
Attach
4Tlth attach R. W.. Gerwig L. N. Vernon R. E. Lehmkuhl
d; A*. Kuhn J. A. Hall A; Sather v
t P> j
4 i.
I* _
* i*
T c**. -*'
i *
a
i `i 4-
1
*
*
i. *
t
**
r *;
b. 4
t s.
F*
VAB.0001029718
f
A3- rftrtnrn
Interoffice Communication
To From
Subject
Robert L. Lembke, M.D.
Oran D. Steffey June 20, 1978
*
*
ANNUAL MEDICAL/INDUSTRIAL HYGIENE INSPECTION - ABERDEEN CHEMICAL PLANT
During June 12-14, 1978, a trip was made to the Aberdeen Chemical Plant for the purpose of physically checking the various operations from the standpoint of OSHA standards which cover General Environmental Control Sanitation, and general use of toxic and hazardous materials.
The following areas were covered from
>
Main Offices Administrative Services West Warehouse Color Weigh Room Manual Bagging Automatic Bagging Line III Dry Blend Control Room Line I Laboratories Plasticizer Building Main Change Room Central Break Room
general industrial standpoint:
Shops Storeroom Dryer Building Steam Generation Plant Compressor Building Building Silos Drummed Material Storage Empty Drum Storage Lubersol Storage Reactor Areas Central Control Room VCM Unloading Phthalic Anhydride
The following comments are made relative to specific areas of the Aberdeen Plant:
Dryefr Building - The overhead sprocket and chain on the third shaker from
the north needs the guard replaced,
ftfXkt'&L'
Old Dryer Building V-10 Area - Fence guards should be installed in front of roller-bearing surfaces located on the east side of the east dryer
3drum and on the west of the west dryer drum. /UiAJr r+>*^
Supply Storeroom - In general, n Aisles are stacked with various the west end of the storeroom need
need to be stored more orderly and materials. The materials in
manner
Plasticizer Building -- The hood in the sample room is not working. It is recommended that a check be made for the use of this hood and if one exists^-- that the equipment be placed in operable condition.
4
VAB.0001029719
Robert L. Lembke, M.D. Page Two June 20, 1978
Development Laboratory - The air register gratings need to be cleaned and maintained In this
The Aberdeen Chemical Plant was found in very good shape. The following is a partial list of improvements which have been made or which are in the process of being finished:
1. A new centralized control room has been constructed. .2 A new dry blend control room with restroom facilities is being
finished. 3. A new dry blend system has been installed on Line III. 4. A new building ventilation-cleaning system has been Installed. 5.. Four new reactors have been located in the area of the old
V-12 reactor building.
6 Great improvements have been made in the VCM unloading area.
This includes a new unloading rack system.
.7. A new PVC manual bagger system is being installed.
8 Progressive improvements are being made In the color weigh
room. This includes the room and vent system being tied into
the new building ventilation-cleaning system. 9. The phthalic anhydride unloading has been completely
re-engineered to unload from tank cars. 10 Great Improvements are being made in the provision of offices
and training rooms for the Safety Division.
11 A new fire training area has been completed and is in use.
12 A new VCM incinerator is being completed.
13 The laboratories have been increased in size. 14 The shops and storeroom supply have been increased in size.
Management and plant personnel are to be commended for t is being made to provide a safe and healthful workplace.
progress which
Oran D. Steffey Industrial Hygienist
*
%
VAB.0001029720