Selecting In-Plant Dust-Control Systems
These guidelines for planning and evaluating dust-control systems point out
how to select from the very first the right system for a particular situation. This is very important, not only from the cost standpoint, but also from the federal and state regulation-compliance standpoints.
LESTEH T. OWEN. G. A. Kleisslar Co.
The Occupational Safety and Health Act (OSHA) of 1970 is one factor making decisions regarding dust con.rol more critical in 1974 than ever before for the chem ical process industries (CPI). Because it is a condition easily monitored, violations are promptly cited. And since collection, separation and disposal of the dust are all involved. Environmental Protection Agency (EPA) regulations are also in force. In addition, labor-union pressures and local and regional agencies have initiated an increasing number of rules on plant-dust control.
Another factor that has become a real consideration in the choice of dust-control equipment is that, for the first time in the history of the CPI. such basics as raw mate rials and energy are in short supply.
Define the Needs and Dust Problem
A well-designed dust-control system will often serve several purposes, if they are thought of early enough:
Compliance--Outside emissions can be controlled for EPA compliance, or in-plant dust for OSHA compliance.
Material Recovery-- Motor-bearing breakdowns, equipment wear, overheating, etc., can occur because dust got into places where it did not belong. And since cleaner plants tend to develop cleaner work habits in em ployees. the dust-control system should be evaluated in this light also. Often, vacuum cleaner hoses can be plugged in for employees to clean their areas (Fig. I).
120
Scrap Removal-- Large-area sheets can frequently be handled efficiently with dust-control systems. This ap plies also to paper and plastic trim. etc., which can also pose problems.
Shutdown--Consider whether the process can stand a shutdown of the dust-control system for cleaning the dust separator. If it is feasible to do so, the system can be rela tively inexpensive; if not, an automatic, continuous, selfcleaning system should be installed.
Special Features--If raw materials are costly, safe guards against contamination, and an automatic system for recycling the collected dust may be warranted. Utility costs may be high enough to make it economical to re turn the cleaned air to the plant to reduce heat loss. The system may need special storage capacity so that it can be emptied only during low-traffic periods.
Next, consider these other parameters: Dust Source-- Dust can be handled most efficiently when trapped at its source. At what points is it gener ated? Is dusting continuous or intermittent? What is the worst condition? The highest flowrate must be specified or the system will likely clog. Surrounding A/morpAere-Consideration should be given to such factors as temperature of plant air, humid ity, equipment, congestion, number of workers and exist ing heating and cooling systems. Dusi Characteristics-These include particle size, shape and distribution, specific gravity, bulk density, hygro-
OCTOBER 14,1974/CHEMICAL ENGINEERING
L6n9S^0iS
Some examples of why
you should look to Elliott for
barrel compressors.
Ammonia 3400 psig, 31,500 hp syn gas (1974)
Natural Gas 10,450 psig reinjection (1972)
Hydrogen 54.000 icfm, 2.8 mol weight (1973)
Mixed Refrigerant 59.000 icfm, 50,500 hp in two casings (1974)
Propane 45,250 icfm, 25,650 hp (1974)
Reformer 20.000 icfm, 9,000 hp recycle (1972)
HvdrorpArlrar
3200 psig, 2900 hp recycle (1971) Hydrotreater
24 stages in two casings at 11,900 rpm (1971)
Methanol 12.000 hp syn gas string (1973)
All Markets 125 barrels, half since 1970
.4*
'-srap -
i*
i ??
n-
Elliott has 20 years experi ence in barrel compressor tech nology. In selecting compressors, experience shows that barrels are required to meet either or both of two basic requirements:
First, high pressure. The cylindrical casing of a barrel forms a natural pressure vessel. At Elliott we actually use the high pressure to your advantage to tighten the inner casing and to balance out impeller thrusts.
Second, molecular weight. Diffusion of hydrogen-rich gases through a horizontally split joint is eliminated. In essence, API Specifi cation 617 requires a barrel design if the partial pressure of hydrogen exceeds 200 psig.
Selecting the correct com pressor for your application doesn't need to be difficult. We have pre pared a new brochure that discusses how you can benefit from Elliott's capabilities and expertise in barrel compressors. For a copy, contact your local Elliott office or write Elliott Company, Division of Carrier Corpo ration, feannette, Pennsylvania 15644.
Twu 34.000 icfm hydrogen barrels tn tandem
In recent years Elliott has been a leader in supplying barrel compressors to meet the growing demands of the chemical and petroleum markets. Listed above are some of our accomplishments.
CHEMICAL ENGINEERING/OCTOBER 14,1974
Elliott
Company
Circle 430 on Reader Service Card 119
OPERATION A MAINTENANCE . . .
VACUUM HOSES help employees clean work areas--Fig. 1
scopic tendencies, toxicity, explosiveness, corrosiveness, abrasiveness. Dust characteristics affect hooding, duct sizing and layout, fan power, separator sizing, materials of construction and filter fabric.
Product Characteristics-- If the material produced is lightweight (flakes, powders, light sheets), the system must gather dust without picking up product. Hood de sign and velocity patterns are important here. Also, the product's surface finish may be of a quality that is down graded by dust, or the product may be susceptible to temperature changes caused by air flow.
Air-Flow Dynamics--These vary with size and number of hoods, nature of dust, production process, and dis tance of hoods from separators. Since OSHA has set spe cific ppm limits on numerous airborne dusts and fumes, the dust-control system must balance these limitations against the expense of in-plant-air turnover rate.
Expansion Plans--Anticipate expansion plans, size the main ducts, and allow space for separators so lhat future needs can be met. One sign of a good system is room for growth, but this must be thought of at the outset
Build or Buy
The next decision is what parts of the system are to be purchased and what can be provided by plant personnel. One extreme is having the entire design and installation done by plant people: the other one is to contract out the entire job on a turnkey basis. 122
The expertise and workload of the plant's engineering group usually determine the extent to which the system is contracted out. Advantages of hiring outside specialists include time saving, wider experience, and availability of the latest dust-control techniques.
It is hazardous today to estimate the cost of a dustcollection system. While the central separator and ex haust fan are offered in standard sizes, the cost of a turn key contract depends on variables such as: (I) the num ber and type of pickup hoods required: (2) size and length of ducts: (3) special anticorrosion coatings or met als needed: (4) anticxplosive safeguards such as special valves, motors and redundant standby equipment: (5) separator size and air-flow/cloth-area ratio; and (6) sepa rator cleaning mechanism (manual, automatic, or contin uous automatic).
An old rule of thumb--which has become less accurate as codes tighten and costs escalate-is that a turnkey sys tem, not including electricaj work, costs from S2.50 to S5/cfm. A 10.000-cfm system would cost from $25,000 to $50,000, including survey work, engineering, fabrication, installation and startup to meet guarantees.
Alternatives to the turnkey contract, however, are nu merous. Plant engineers could develop the basic concept with consultants designing the system, or they could take the project through the engineering stage and ask for bids on the specifications. Then, perhaps only the separa tor and blowers need to be purchased.
Previous experience of staff engineers should be eval uated realistically before taking on the job at the plant. Experience in heating, ventilating and air-conditioning (HVAC) can be helpful, but it is not enough. The prin ciples of dust collecting, conveying, and separating are quite different. HVAC systems usually work under posi tive pressure, with minimum disturbance of people by air flow. By contrast, dust-control systems operate under negative pressure, inducing air flow in exactly the right places. If the best approach seems to be to turn to outside system suppliers, find one that you can trust so that the job may be left entirely to him.
Anatomy of a System
Look for evidence of good design in the overall system and its major components, such as hoods, duces, separa tor and blower. Simplicity can mean efficient operation and less maintenance The system should occupy as little space as possible, and not interfere with operations.
Hood Design--Look for solid, welded construction, where airflow dynamics have been given proper consid eration. The hoods should: be well anchored and as close to the dust generator as possible to reduce duct length and improve efficiency: out of the way of worker motion and visibility; and not interfere with plant lighting. Swingaway hoods should be specified where needed.
Duct Design-Flange or welded slip-joint construction provides rigidity and air tightness. Look for long, straight runs to sustain good flow patterns. Branches should enter the main duct at no more than a 30-dcg angle to avoid abrupt changes in direction and velocity of air (Fig. 2). Any duct descending to a dust-generating point must be so placed that the operator will not want to remove it.
OCTOBER 14,1974/CHEMICAL ENGINEERING
ST 0255498
Separating fact from fiction:
bolted vs.weldedtanks.
661SS201S
FICTION: Welded tanks fit the are bulky and more expensive to ship. know-how unequalled in the bolted
job better because they are custom
The cost of labor for on-site weld tank industry.
made.
ing of tanks is high. , sometimes
The bolted tank is just one basic
FACT: While welded tanks are the labor available is of dubious qual component Butler offers as a part of
more likely to be totally custom fabri ity. All of this adds to the price you our complete systems capability in
cated tor the job. this fact is no assur pay for welded tanks.
pneumatic materials handling We
ance that they are better tailored to
Also. Butler bolted tanks are make all the key pneumatic equip
meet engineering requirements. But coated at the factory, under con ment parts and controls for automa
ler bolted tanks are individually engi trolled conditions, by ex verienced tion. Every piece is designed to do its
neered and computer calculated to ciruj highly skilled workmen. On field- job precisely, accurately, reliably, in
take into account weight and flow of welded tanks it is difficult to main exact harmony with every other com
material stored and environmental tain uniform quality control of ponent It's available to you the way
conditions such as wind load ai.J coatings.
you want it. one piece at a time or ail
seismic factors.
For price and perlormance, be together--including total engineering
FICTION: Welded tanks perform sure to investigate Butler bolted and turnkey construction. Let us
better because they are made of heav tanks before you write storage speci know what you need We can help.
ier gauge steel.
fications. We've been makinj them
Fill out and mail the coupon to
FACT: Better performance is fre for more than 60 years, and every day for complete information about
quently not the reason heavier gauge Butler tank is backed by engineering Butler Bolted Steel Tanks.
steel is used in welded tanks. The fact
is that there is no choice. Often, the less costly, lighter gauge walls would
<5l/TLgff>
~i
be more than adequate, but the lighter gauges (used in bolted tanks) are not suitable for welding.
FICTON: Welded tanks are more
Butler Bulk Handling and Storage Dept 210 P. 0. Box 917 Kansas City. Mo 64141
"weatherproof" . . will protect their
contents better than bolted tanks. FACT: Butler bolted tanks are
designed to hold in stored liquids . . which is much more difficult than
Have your representative call on mo. QSend information about Butler Bolted
Steel Tanks
Cm also interested in
keeping wind and rain ouf.
In addition to tight, safe storage,
flexibility of design and greater econ
omy in basic materials cost. Butler
Name
bolted tanks offer other advantages
Title__________________
over welded tanks. For instance. Butler bolted tanks
are shipped in compact, manageable
Company Name______ Street_
units which permit maximum ship
I City..-- StateI
ping and erection economy. Welded
| ZipPhone________________
|
tanks small enough to be shop-welded
iI
CHEMICAL ENGINEERING/OCTOBER 14,1974
Circle 431 on Reader Service Card 121
OPERATION & MAINTENANCE .
Flexible ducts help with difficult-to-reach hoods. How ever. rigid ducts perform better and usually turn out to be more economical.
Fabric Separators This unit should be easily acces sible for inspection and for emptying in any kind of weather without stopping system operation. It should also be housed with firm supports. A knockout chamber to remove some particulate matter, especially when the dust is abrasive, improves the efficiency and the life of the separator The cleaning of its filter tubes, whether done by a mechanical shaking device or by jets of clean ing air. should be simple. Check for correct airflow-tocloth-area ratio, and for safeguards against wear points at the entrance and exit of the tubes.
The choice of a mechanical shaker or a pulse air cleaner depends on the nature of the dust. If it cannot be efficiently removed bv blowing out the lubes, mechanical shakers may be needed, even though this requires that pressure be taken offi the tubes while they are shaken.
If the process will not allow shutdown for filter clean ing, then either a continuous automatic method--where parts of the mechanical-shaker separator can be taken olfslrcam for cleaning--or a continuous air-cleaning filter must be provided. Usually, in svstems handling 20.000 cfm or less, it ts more economical to install a pulse air cleaning filter than a continuous-automatic mechanicalshaker separator.
Other Separator';--Other than fabric-tvpe dust separa tors. the kind most commonly seen for dry materials is the cyclone. But with air-quality codes in most states al ready requiring better than 90c efficiency in separating particulate matter from air (or emissions of no more than 0.02 grains/ft3). it is unrealistic to expect a cyclone cleaner to meet air-pollution codes.
Nevertheless, cyclones are valuable as precleaners in dust-control systems handling (I) abrasive material that 124
can be partially separated from the dust to reduce wear on fabric filters: (2) thin, stringy material such as paper, plastic webs or lint that can be precleaned from the air to reduce the frequency of cleaning fabric filters; and (3) heavy loads to help take the load off the fabric filter.
Another separator is the gravity-settling chamber. Again, this usually acts as a preclcaner rather than as a final separator. Consisting of a battled chamber placed in the main airflow path, the entering air drops in velocity and changes direction. Heavy particles then fall out of the air stream to the chamber bottom, where they are pe riodically removed. This unit is often included when there is clanger of drawing sparks into the pickup hoods, because water-run into the chamber bottom--extin guishes the sparks.
Although other types of separators have also been used, it is difficult to generalize for specific situations what alternatives there might be for fabric-filter systems. Some of the newer approaches to dust separation may become important in the future, but the standard, central filter with fabric media continues to be the most efficient separation method for the amount of energy expended.
Exhausters--The size of these units should he such as to move the required air with minimum power consump tion. Check for inspection access doors. Look also for proper guards on V-belts, as well as adequate belt venti lation. If fans are on a platform, there are codes on ac cess and strength of platform and ladders that should be consulted.
Choosing a Contractor
To help evaluate outside consultants or system sup pliers for your dust-control problem:
1. Visit a few, recent dust-control systems the contrac tor has engineered and installed, and discuss the systems with your counterparts in these plants.
2. Is the contractor familiar with your product and manufacturing process? Be certain he is taking a systems approach to your dust-handling job. Gathering the dust and conveying it to the separator must be as efficient as the separation of the dust from the air.
3. Ascertain that the supplier is familiar with state and federal air-quality codes, and is experienced in filing ap propriate compliance forms with labor departments and air-pollution control agencies. These codes change fre quently. In some instances, only accredited engineers can file the compliance forms.
4. Has the contractor considered worker movements and avoided changing accustomed motions? Can equip ment be inspected and serviced without undue exertion? Has he discussed work motions and paths with machine operators'1
5. Will the contractor perform every function needed in the job? If not, who has responsibility for the subcon tracted aspects? The functions usually required of the contractor are: testing, source analysis, concept develop ment. engineering and drafting, fabrication, installation, startup and followup.
Factors beyond bid figures for dust-control systems must be considered. See to it that total installation costs and successful startup are included. Ascertain that the
OCTOBER 14,1974/CHEMICAL ENGINEERING
ST0255500
Flame
Tough flame retardance specs and
tight budgets are rough. But you can
Retardance meet 'em. Specify FRP pipes, tanks, ducts, demisters, etc., made with ATLAC 711-05A polyester resin.
ATLAC 711-05A (plus 3% Sb203) com bines top flame retardance ratings
with resistance to the broadest
Is NoSweat
range of acid and alkali corrosives of all polyester resins. Not only that, it is years ahead of competition in terms of successful installations, and backs its story with support-
technical and literature--that's
second to none. ATLAC
IfsThe Budget isthe proven resin. As far as flame retard ance is concerned,
ATLAC 711-05A with antimony oxide meets
the requirements of
That Makes
NFPA Code 31 which covers blower and exhaust systems.
Specify ATLAC for top flame retard ance and corrosion resistance,
and enjoy lower initial equipment
costs, lower installation costs, and
You
lower maintenance costs, too.
Burn.
ST075550I
There's more to
the ATLAC story. Write and ask for LP-29.
Hot (< handlor. 27' dlamotor glob* mad* with ATLAC 711-05A resin at
Weyerhaeuser Co., Longview, WA, accumulates spent digester gases and meters them Into lime kilns or hog burners. Unit has capacity of 10,000 cubic foot, outer layer has UV absorber added.
1ci\ ICI United States Inc. Specialty Chemicals Division Wilmington, Delaware 19897
CHEMICAL ENGINEERING/OCTOBER 14, 1974
Circle 432 on Reader Service Card
123
OPERATION A MAINTENANCE . . .
system will not adversely alfect production or product quality, that operating costs of the system arc taken into account, and that system capacity is optimum for your operation.
Look lor the danger of secondary problems such as may be encountered in dust-hopper emptying and dust disposal at the separator, or for weather effects on sepa rator inspection and emptying, and for a possible prob lem with system noise.
Have the contractor definitely determine any inter ruption of production during system installation. Check on effect, if any. of system on insurance rales. Ask for de tails on prefabrication of hoods, ducts and supports be fore delivery. You may eliminate some confusion, inter ruptions and hazards.
Difficult Problems Solved
Drastic improvements in plants where dust control was once considered impossible are now accomplished evers day. Some examples are the following:
Explosive Dust In the manufacture of a basic compo nent for plastics, the material was so explosive that in stalling a new dust-control system had to be approached with the assumption that explosions in or around the dust-control system were inevitable. This required spe cial precautions, not only in design and system function, but in erection as well.
Therefore, the system was designed with: exhausters with nonferrous fans to eliminate sparking: explosionproof motors: heavy, shock-proof casings on separators: large blowout panels on hoods and ducts (with tethers, xo they could not become missiles): explosion- or shocktriggered shutoff valves in the ducts to isolate and elimi 126
nate secondary explosions; separators isolated from re mainder of system; high ratio of vent area to cubic con tent: explosion vents between plant and separators;
careful grounding of all components: sparkproof bins; and a special two-stage unloading arrangement to seal off collected dust from the separator while the hopper
was unloaded.
In erecting ihe system, no onsite welding, brazing or soldering was permitted. Parts were prefabricated, and no electric tools were used at the site. To prevent sparks,
only brass hand-tools were used for assembly purposes. Fine, Toxic Dust-M a leading manufacturer of pig-
mem compounds, dust in the difficult-to-ctipiure 0 10 to 10-micron range was generated. Al two of the 200-gal mixing tanks, when 50-lb bats of pigment powder were added, bursts ol'dust resulted from dumping the bags.
This problem was solved by designing the collection hoods for these tanks as "Hip tops.'' which raise to permit adding the sacks of pigment, and then close until the dust is taken into the system. Further precautions included pressure-relief vents and a nonferrous exhaust fan to pre vent sparks.
Siring). High-Volume Asbestos Ou.tr--In a floor-tile manufacturing plant, some 3.500 Ib/d of dust was gener ated in grinding and screening of vinyl asbestos, lime stone and various chemical pigments. Employee health and safety, product quality, community relations and housekeeping were at stake.
Therefore. 20 intake hoods at dust generating stations and conveyor belts were installed, and hoods--varying in size to accommodate the density of generated dust--were located either over or under the major dust sources, such as the grinder, screens and conveyor exchange points (Fig. 3). A large, two-hopper dust separator was chosen to handle the large volume. About 209c of the dust can now be recycled to the production process.
Outdoor Dusts--Both OSHA and EPA compliance
were at stake and community relations were in jeopardy for a ready-mix concrete company, which generated large volumes of highly visible dust at its outdoor mixertruck loading station. A specially designed swingaway collection hood was therefore installed, which collects ihe dust at its source. During loading, the hood drops into position over the loading-hopper discharge and over the truck-loading gate. Then it swings out of the way when loading is complete, so trucks may move freely in
and out of the area. The swingaway hood is connected to a separator, which draws in the cement particles Emis sions were reduced 90%.
Meet the Author
Lester T. Owen is sales engineering manager for dust-control systems with G & Kessler Co . Vt-T TayVor no. Edison. NJ 088t? During the seven years he has been with Kie ssler he has been involved in solving dust-control problems lor Ihe chem ical process industries Por lo join ing Klessler. he soenl t2 years with Monsanto Chemical Co. Springfield. Mass -where he was production su perintendent--and at the Addystor. Ohio plant where he was plant engi neer Selore. he was general man ager o' Pfizer s Qu'g'ey O* m Sayrevtite. N J He studied mechanical engineering at the University of Mis souri
OCTOBER 14,1974/CHEMICAL ENGINEERING
S f0255502