Calculations
21. Calculate and report fiber density on
the filter, E (fibers/mm1); by dividing the total
fiber count, F; minus the mean Held blank count B, by the number of fields, n; and the field area, A* (0.00785mm* for a properly calibrated WaHon-Becketl graticule):
. g. ------------ ftberg/mm* (n)(A,)
22.' Calculate the concentration, C (f/cc), of fibers in the air volume sampled. V (L). using the effective collection area of the filter, A* (385 mm* for a 25-mrn filter):
c~ _ (E)lAc)
VllO5)
Note.--Periodically check and adjust the value of A, if necessary.
Appendix C to 1926.58--Qualitative and Quantitative Fit Testing Procedures-- Mandatory
Qualitative Fit Test Protocols
I. Isoamyl Acetate Protocol * A.-Odor threshold screening. 1. Three 1-liter glass jars with metal lids
(e.g. Mason or Bell jars) are required. 2- Odor-free water (e.g. distilled or spring
.water) at approximately 25 *C shall be used for the'solutions.
3. The'isoamyl acetate (IAA) (also known as Isoperityl acetate) stock solution is-.. prepared by adding 1 cc-of pure IAA to 800 cc of-odor free water in a il-literjar and shaking' for 30 seconds: This solution shall be ' prepared new at least weekly. - 4. The screening test shall be conducted in a room separate from the room used for actual fit testing. The two.rooms shall be well ventilated but.shall not be connected to the same recirculating ventilation system.
5. The odor tesl'sofution is prepared in a second jarby.placing 6.4 cc of the stock solution into 500.ee of odor free water using a dean dropper or pipette. Shake for 30 seconds and allow to stand for two to three ' minutes so that the IAA concentration above the'liquid may reach equilibrium.This solutionmay be used for only one day.
0. A testblank is prepared in a third jar by adding SOD 6c of odor free water.- 7. Iite odor test'aiid test blank jars shall be labelled 1 and 2 for jar identification: If the labels are put on the lids they can be periodically peeled, dried off and switched to maintain the integrity of- the lest
.6. The following instructions shall be typed on a card and placed ori-the table in front of the two tearjars (i.e. 1 snd 2): `.The purpose of this test is to determine if you can smell . - banana oil at a low. concentration. The two bottles in front of you contain water. One of
these bottles also contains a smalt amount of banana oil. Be sure the covers are.on tight, then shake each bottle for two seconds, . Unscrew the lid of each bottle, one aUa time, and sniff at the mouth of the bottle. Indicate to the test conductor which bottle contains banana oil."
9. The mixtures used in the IAA odor detection test shall be prepared in an area separate from where the test is performed, in order to prevent olfactory fatigue in the
subject. 10. If the test subject is unable to correctly
identify the jar containing the odor test solution, the IAA qualitative fit test may not be used.
11. If the test subject correctly identifies the jar containing the odor test solution, the test subject may proceed to respirator selection and fit testing.
8. Respirator Selection.. 1. The test subject shall be allowed to pick the most comfortable respirator from a selection including respirators of various sizes from different manufacturers. The selection shall include at least five sizes of elastomeric half facepieces, from at least two manufacturers. 2. The selection process shall be conducted in a room separate from the fit-test chamber to prevent odor fatigue. Prior to the selection process, the test subject shall be shown how to put on a respirator, how it should be positioned on the face, how to set strap tension and how to determine a "comfortable" respirator. A mirror shall be
available to assist the subject in evaluating the fit and positioning of the respirator. This instruction may not constitute the subject's formal training on respirator use, as it is only a review.
3. The test subject should understand that the employee is being asked to select the respirator which provides the most comfortable fit. Each respirator represents a different size and shape and. if fit properly and used properly will provide adequate
protection. 4. The test subject holds each facepiece up
to the face and eliminates those which obviously do not give a comfortable fit. Normally.-sclection willbegin with a halfmask and if a good fit cannot be found, the subject will be asked to test the full facepiece respirators. (A small percentage of users will not be able to wear any half-maskj
5. The more comfortable facepieces are noted; the most comfortable mask is donned and worn at least five minutes to assess comfort. All donning and adjustments of the facepiece shall be performed by the test subject without assistance from the test : conductor or other person. Assistance in : assessing comfort can be given by discussing the points in #6 below. If the test subject is not familiar with using a particular respirator, the test subject shall be directed to don the mask several times and to adjust the sirups each time to become.adept at setting proper tension on the straps. . 6. Assessment of comfort 9hall include -
reviewing the.following points with the test subject and allowing the test subject .adequate time to determine the.comfort of the respirator: .
Positioning of mask on no9e.
Room for eye protection. Room to talk. Positioning mask on face Qnd cheeks. 7. The following criteria shall be used to help determine the adequacy of the respirator fit:
Chin properly placed. Strap tension. Fit across nose bridge. Distance from no9e to chin. Tendency to slip. Self-observation in mirror. 8. The test subject shall conduct the conventional negative and positive-pressure fit checks before conducting the negative- or positive-pressure test the subject shall be told to "scat" the mask.by rapidly moving the head from side-to-9ide end up and down, while taking a few deep breaths. 9. The test subject.is now ready for fit testing. 10. After passing the fit test, the test subject shall be questioned again regarding the comfort of the respirator. If it has become uncomfortable, another model of respirator shall be tried. 11. The employee shali be given the opportunity to select a different facepiece and be retested if the chosen facepiece becomes increasingly uncomfortable at any time. C. Fit test. 1. The fit test chamber shall be similar to a clear 55 gal drum liner suspended inverted over a 2 foot diameter frame, so that the top of the chumber is about 6 inchesabove the test subject's head. The inside top center of the chamber shall have a small Hook attached. 2. Each respirator used for the fitting and fit testing shalibe equipped with organic vapor cartridges or offer protection against organic vapors. The cartridges or masks shall be changed at least weekly. 3. After selecting, donning, and properly . adjusting a respirator, the test subject shall .
wear it to. the fit testing room.THia room shall be separate from the room used for odor threshold screening and respirator selection, and shall be well ventilated, as by an exhaust. fan or lab hood, to. prevent general room . contamination. . 4. A copy of the following test exercises and rainbow passage shall be taped to the . inside of the test chamber.
Test Exercises
i. Breathe normally, . .. ii. Breathe deeply..Be certain breaths ore deep and regular... iii. Turn head all the way from one side to the other. Inhule on each.9ide. Be certain movement is complete. Do not bump the . respirator against the shoulders. iv; Nod head up-and-down. Inhale when head i9 in the full up position (looking toward ceiling). Be certain motions are complete and made about every second; Do not bump (he respirator on the chest. y. Talking. Talk.aloud and slowly for several minutes. The following paragraph is called the Rainbow Passage. Reading it will result in a wide range of facial movements, and thus be useful to satisfy this requirement..