BFG TECHNICAL DOCUMENT
INTERNAL BFG USE ONLY
A BFGOODRICH
AUTHOft
M. 0. MELE
UQUE5TCO BY:
S. F. DREWS
ANALYTICAL TECHNOLOGY ANO SERVICES REPORT
GXOUP/CHVUtON
ALTC/PSC
DATE
8/30/88
IOC BOOK tBUiNCE
002-231-53
RETENTION
423 soi-ooi
PROJECT NO.
3195
CROUP HU ACa NO.
88-149
SS71/7 AffMNXNa FACE NO.
RESIDUAL VINYL CHLORIDE IN GE0NR LATEX AND WASTE WATER SAMPLE
SUMMARY '
Cumulus Fibres, Inc., uses GeonR 352 latex, and Is concerned about legal problems due to vinyl chloride monomer (VCM) In effluent water. The gas chromatography (GC) laboratory was asked to measure^the VCM levels In a sample of a "Geon Mix" used at Cumulus, and In samples of Incoming city water and effluent water (the effluent water had a high total solids level which may be due to latex overspray). The Geon mix sample had 6 mg/kg (ppm) residual VCM, the city water 0.3 ng/g (ppb), and the effluent water 31 ng/g VCM. Cumulus must determine whether this level Is In compliance for their Industry, community, etc. However, If It Is too high, filtering the water would be one way of reducing It.
EXPERIMENTAL
All samoles were analyzed using a modified version of ASTM Standard Method D-4443-84. Two mL aliquots of each sample were sealed In standard headspace vials. These were equilibrated for 60 min at 90C and then analyzed with a Perkln-Elmer Sigma 2000 GC equipped with an HS100 headspace sampler, a photoionization detector, and a 9 foot by 1/8 Inch column packed with 0.19S picric acid on Carbopack C. The Geon mix and the effluent were calibrated separately by standard addition. The calibration factor for the effluent was used for the city water.
cc: G.E.Thompson
L.Grady E.J.Leeson J.Lewis M.Moore CTF
M.D.Mele
BFG12913
h*
%
This document contains confidential Information and is tor internal BFG use on a "need* to-know" hislt Store in secure area when not in use. Destroy wnen no longer needed.