Document rppKgq85ze4Y7noJo8XojJ7Nr

A) j^} jj 5 Pfc?^L5 LAIVI021330 B001167 6113 16802 f ii !| *I o i 2 z<>03<-33-0gr I till' u l U) Uj a3 *o > cr ; r; < 'i vw l -1 o< | O o3? i uj | oa : "1 ! w* O ; 5| uj _ j 131 3 ' 1: i 1 | t: i i | 1 1; 1 , 1 j1 ' ` 3, fr- j: :io r i i1 ! f i! '11: !I " V -J ~ 1 * IT- I 1 !" '1 l` ' ! ' ' !"! O! S" ^i il 5- s: r* i No i O' 1 r-i uO 1 CJ <V 3 X. VI i r'l < f"1 p^ , i-i r i , (uo o la uO ! -a ~a 1 ,u I 3 <_* icj 1 y |CJ j<J' 1 1 | 33' >- 53 ^-e*G | -* -- <--*:r~c:: , r* a J vji vl vi v) ' | vl J5 / vj >o ;t *u s ` ; |a a '' | i qZZ =i '^! ! 51- =l~:|I;Ii 1 iIiIiJ,li!ll *I1 U : !i--i. i is *!* t5 5: ! iuii J-. --1 i- 1 a. -at 1 34 n istu* .d j 1 ,i :s V7 VI aj yj 1 | oO' -. i 1 ii ,. i1 ii l , i i w ! ; i 1 ; : r- i n 1 .1 ! <'"jH <y"S -<O ij*; t . :i : i1 il.cj-i)n' i; H 6 16804 B O O llG fi il LAM021332 6113 BQ01170 16805 CEA 3324 McKee LC-4951 SAB ENERGY REDUCTION SUMMARY OF WORK FOR INSULATION Spec 1A-4 Dace: 03-19-79 Rev. 0 1.0 SCOPE 1.1 The Contractor shall provide all insulation material, labor, supervision, tools, equipment, and accessories to insulate ductwork, pipe and equipment at Monsanto Company, Chocolate Bayou, Alvin, Texas. 1.2 Insulation materials and application shall be in accordance with specifications, drawings and other documents included in this Insulation Bid Package. 1.2.1 The Pipeline Schedule shall be used to determine lines to be insulated, insulation type, weather barrier and insulation thickness on piping. 1.2.2 Form ES11, Equipment Insulation and Painting Summary, shall be used to determine those items of equipment which are insulated, insulation type, weather barrier and insulation thickness. 1.2.3 The isometrics and other piping drawings shall be used to determine size and configuration of lines. 1.2.4 When a line is to be insulated all pipe sizes of that line are to be insulated even though some sizes may not be listed on the Pipeline Schedule. 1.2.5 When lines are heat traced, two isometric sheets may be furnished. 1.2.6 The insulation contractor shall be responsible for locating lines to be insulated using the plot plans and other data furnished. 1.2.7 Sections of insulated lines which are carried inside vessel skirts shall be insulated the same as sec tions on the exterior of the skirts. 1.2.8 When a line is insulated, all in-line components shall also be insulated except where noted. 1.2.9 All insulation required for personnel protection is to be considered a part of this contract package. 2.0 COORDINATION 2.1 The Contractor shall coordinate his work with all other dis ciplines so as to complete the work as expeditiously as possible. END OF SPEC 1A-4 LAM021334 6ii3 16806 B001171 SL315/155 Page 1 CEA 3324 McKee LC-4951 SAB ENERGY REDUCTION THERMAL INSULATION Spec 15K 1 Date: 03-19-79 Rev. 0 1.0 GENERAL 1.1 Scope - This specification describes the materials required and the application of insulation and weather-barriers for use on industrial piping, vessels and equipment shown in the accompany ing drawings and documents. 1.2 Related Documents Specified Elsewhere Identification Symbols and Summary Construction Details Elevated Temperatures Barrier Construction Details Kll.l STD 2 K11.4 STD 10 K11.4 STD 80 1.3 Quality Assurance 1.3.1 Qualification of Applicator The insulation shall be performed by an insulation contractor approved by Monsanto the insulation contractor shall furnish competent supervision and labor experienced in this class of work and shall also furnish materials, equipment and scaffolding necessary to complete the installation. 1.4 Product Delivery and Storage 1.4.1 Marketing Shipping containers shall be legibly marked with the name of the manufacturer, material, size, type and quantity. 1.4.2 Storage Materials shall be sotred at the job site in a building or shelter which will completely protect them from the weather. Heated storage facilities are not required, except for materials requiring freeze protection (PVA mastic, water base adhesives, etc.). Material shall be retained in shipping containers until ready for use. 2.0 PRODUCTS 2.1 Material Specification The following Thermal Insulation System specifications are a part of and are to be attached to this spec. K11.2 STD 5 Rigid Fibrous Glass System K11.2 STD 9 Rigid Mineral Fiber System 2.1.1 . SL316/156 Materials Callout Materials are called out on piping and equipment drawings. Equipment Summary, and the Pipeline Schedule. ROOI1 6113 16807 Page 1 LAM021335 CEA 3324 McKee LC-4951 THERMAL INSULATION (continued) Spec 15K 1 2.2 Solvents Solvent materials used for thinning and clean-up shall be those recommended by the material vendor. Deviation from these recommendations is not permitted. 3.0 EXECUTION 3.1 Installation Before the application of any insulation, all piping, vessels and equipment shall be released by the Engineer. This is to assure that painting, inspection and testing proce dures have been completed. Any insulation applied to these items without release by the Engineer is subject to removal by the Contractor at his own expense. 3.1.1 Special Requirements Any welding required to attach equipment name plates, insulation support rings and angles, clips, studs, and rods for bands and wires to the surface of the equipment, vessels or piping shall be by others. Many of the vessels and items of equip ment to be insulated are fabricated of special alloys or receive special heat treatments. No welding shall be done for additional insulation attachments except spotwelding of pins to heating duct surfaces where approved by the Engineer. 3.1.2 Surface Condition Surfaces to be insulated shall be clean and dry. The insulation contractor shall be re sponsible only for the removal of oil, grease, dust, and similar accumulations of surface dirt; he will not be held responsible for the removal of mill scale, rust scale or deposits, old paint, or similar firmly adhering accumulations. 3.1.3 Protection At the close of work each day, insulating materials that have been applied during the day shall be protected from the weather by coverings or methods accept able to the Engineer. However, insulating materials fully protected by weather barrier mastics or jacketing need not be so protected. 3.2 Installation Specifications The following listed installation specifications edited to comply with project requirements shall be attached to and become a part of this specification. END OF SPEC 15K-1 80891 C II9 SL316 /157 Page 2 LAM021336 CEA 3324 McKee LC-4951 SAB ENERGY REDUCTION INSTALLATION SPECIFICATION SYSTEM 5XX RIGID FIBROUS GLASS Spec 15K-5 Date: 03-19-79 Rev o 1.0 GENERAL 1.1 Scope - This specification covers the installation of Rigid Fibrous Glass insulation including the barrier application, to piping, vessels and equipment. 1.2 Application - This specification is limited, in that it only covers the application of the insulation. It is therefore to be used with the project specification 15K-1. 2.0 PRODUCTS 2.1 Materials used in this specification are specified in Part 2 of the project spec 15K-1, and the specified system is de scribed in K11.2 STD 5. 3.0 EXECUTION 3.1 Information and instructions contained in Part 3, Execution, of the project specification 15K-1 are applicable to the type of insulation specified herein. 3.2 Pipe Insulation 3.2.1 Piping Supports - Install pipe saddle insulation com ponents at pipe support locations (pipe handers, steel supports, etc.). The thickness of the load bearing saddle insulation is the same as adjacent insulation thickness and as specified in the drawings and schedule. 3.2.2 Straight Pipe - Apply the pipe insulation directly to the pipe surface of the thickness shown in the drawings and pipeline schedule. Secure insulation to the surface with joints butted tightly together. Application methods are shown in K11.4 STD 10, Insulation Construction Details. 3.2.3 Components - All pipe components shall be insulated except as noted on the drawings and schedule. Insulation compon ents may be premolded or of mitered construction. Pre molded insulation fittings shall be installed in accord with the manufacturer's instructions. Mitered insulation pieces shall be butted tightly together and secured to the pipe component with wire. Insulation cement shall be used to fill voids, surface breaks and irregularities to form a smooth configuration. 6113 16809 ii001174 SL317/158 LAM021337 Page 1 CEA 3324 McKee LC-4951 SYSTEM 5XX RIGID FIBROUS GLASS (continued) Spec 15K-5 3.3 Vessel and EauiDment Insulation 3.3.1 General - Apply the insulation in thickness shown on equipment drawings directly to the surface with tightly fitted joints. Where applicable use curved segments, or pipe covering sections to obtain tight joint con struction. Application methods are shown in K11.4 STD 10, Insulation Construction Details. 3.3.2 Cylindrical Surface - Apply insulation directly to the surface with tightly fitted joints. If necessary to make the insulation conform to the cylindrical surface cut the outside surface to a depth of not greater thanhalf the insulation thickness. Secure the insulation in place with 3/4" strapping on 12" centers. 3.3.3 Flat Surfaces - Apply insulation directly to surface with joints butted tightly together. Secure insulation to surface with wire attached to studs or with support pins. 3.3.4 Vessel Heads - Fit insulation in place and butt joints tightly together. High compression sheet insulation shall be applied to the top head surface of vessel and equipment subjected to foot traffic. Secure insulation in place with 3/4" strapping, spaced at 12" centers around the head perimeter. A small quantity of wire may be used for securing insulation where strapping is impractical. Fill voids, depressions and irregularties in the insulation surface with insulation cement. Apply insulation to nozzles, manholes, legs and skirt as shown in K11.4 STD 10, Insulation Construction Details. 3.4 Barrier Application - Piping Vessels and Equipment 3.4.1 Piping Field Applied - Jacketing applied to insulated piping shall be cut to suit the outside diameter; provide a 2" minimum lap at all joints. Position the laps to provide maximum protection against wind, blow ing rains and water cleaning operations. Secure the jacket in place with wire or strapping. Use wire ties at a maximum spacing of 6" for insulation outside dia meter to 6". Use 1/2" strapping at a maximum spacing of 9" for insulation diameter greater than 6" and up to 24". Use 3/41' strapping at a maximum spacing of 12" for insulation diameter greater than 24". SL317/159 Page 2 vo LAM027338 BC01175 '1 1 3 16 8 lo CEA 3324 McKee LC-4951 SYSTEM 5XX RIGID FIBROUS GLASS (continued) Spec 15K-5 3.4.2 Components - Apply premolded jacket or membrane rein forced mastic to in-line pipe components, pumps, instru ments and special fittings. Premolded jacket shall be installed as directed by the manufacturer and se cured with adhesive and tape. Installation of mastic barrier shall be uniform with reinforcement cloth embeded into wet mastic. Provide a 2" minimum lap at joints. The minimum dry-film thickness of the mastic barrier shall be as specified in the materials specifications. Apply sealer at joints and openings in the jacket for complete weatherproofing for both indoor and outdoor service. 3.4.3 Vessels a. Cylindrical Sections Pre-cut the metal sheets to fit snugly around protrusion and fittings. Apply the jacket to the insulated surface to obtain a snug smooth fit. Circumferential and longitudinal metal joints shall be lapped a minimum of 2". Metal laps over the mastic mem brane barrier shall be lapped a minimum of 4". Position the laps to provide maximum protection against wind, blowing rain and water cleaning operations. For vertical vessels where three or more sheets are unsupported, use "Z" clips spaced at 3" centers around the perimeter. Secure the jacket in place with 3/4" strapping at a maximum spacing of 12". b. Vessel Heads Apply the mastic barrier to insulated vessel heads and other insulated surfaces as spe cified. Apply a uniform film of mastic to the surface and embed reinforcement cloth into the wet mastic. Apply additional mastic to the entire mem brane surface to make a smooth wrinkle free surface. Provide a 2" minimum lap at joints. The minimum dry-film thickness of the mastic barrier shall be as specified in the materials specifications. Ap plication details are shown in K11.4 STD 80. Apply sealer at joints and openings in the jacket for complete weatherproofing in outdoor and indoor service. END OF SPEC 15K-5 6113 16811 SL317/194 Page 3 LAM021339 0 0 ll7 g CEA 3324 McKee LC-4951 SAB ENERGY REDUCTION INSTALLATION SPECIFICATION SYSTEM 9XX RIGID MINERAL FIBER Spec 15K-9 Dace: 03-19-79 Rev o 1.0 GENERAL 1.1 Scope - This specification covers the installation of Rigid Mineral Fiber insulation including the barrier application, to piping vessels and equipment. 1.2 Application - This specification is limited, in that it only covers the application of the insulation; it is therefore to be used with the Project Specification 15K-1. 2.0 PRODUCTS 2.1 General - Materials used in this specification are speci fied in Part 2 of the Project Spec 15K-1, and the specified system is described in K11.2 STD 9. 3.0 EXECUTION 3.1 General - Information and instructions contained in Part 3, Execution, of the Project Specification 15K-1 are applicable to each type of insulation specified herein. 3.2 Pipe Application 3.2.1 Piping Apply the pipe insulation directly to the pipe surface of the thickness shown in the drawings and schedule. Secure insulation to the surface with joint construction butted tightly together. Application methods are shown in K11.4 STD 10, Insulation Construction Details. 3.2.2 Components Components shall be insulated except as noted in the drawings and schedule. Mitered insulation pieces shall be butted tightly together and secure to the pipe component with wire. Insulation cement shall be used to fill voids, surface breaks and irregularities to form a smooth configuration. 3.3 Vessel and Equipment Insulation 3.3.1 General Apply insulation directly to the surface with tightly fitted joints. Where applicable use curved segments, or pipe covering sections to obtain tight joint construction. Application methods are shown in K11.4 STD 10. TM <h <-i 3.3.2 Cylindrical Surfaces Apply directly to the surface. Serrate outer surface no greater than half of the insul ation thickness, if necessary, to make the insulation conform to the surface. Secure the insulation in place with 3/4" strapping on 12" centers. LAM021340 12001177 SL318/195 Page 1 CEA 3324 McKee LC-4951 SYSTEM 9XX RIGID MINERAL FIBER (continued) Spec 15K-9 3.3.3 Flat Surfaces Apply directly to surface with joints butted tightly together. Secure insulation to surface with wire attached to studs or with support pins. 3.3.4 Vessel Heads Fit insulation in place and butt joints tightly together. Secure insulation in place with 3/4" strapping spaced at 12" centers around the head perimeter. A small quantity of wire may be used to secure the insul ation where strapping is impractical. Fill voids, depressions and irregularities in the insul ation surface with insulation cement. Apply insulation to nozzles, manholes, legs and skirt as shown in K11.4 STD 10. 3.4 Ductwork 3.4.1 Round Duct Cut insulation to fit and apply directly to the surface with tightly butted joints. Secure insulation with 3/4" strapping, spaced at 12" centers. Seal all joints with tape. Secure the jacket in place with 3/4" strapping at a max- . imum spacing of 12". 3.4.2 Flat Surfaces and Transitions Install support pins at a rate not to exceed one pin per 2 sq. ft. of surface. Insulation shall be cut to fit surface and shall be secured to ductwork by impaling insulation on support pins. Joints shall be tightly butted and secure insul ation to surface with pin washer. Insulation shall be cut to fit access doors, for removal, and replacement of door without disruption to insulation. 3.5 Barrier Application - Piping, Vessels and Equipment 3.5.1 Metal Jacketing (System 9 MC) 3.5.2 Field Applied Cut jacketing to suit outside diameter and provide a 2" minimum lap at all joints. Position the laps to provide maximum protection against wind, blowing rain and water cleaning operations. Secure the jacket in place with wire or strapping. Use wire ties at a maximum spacing of 6" for insulation outside diameter to 6". Use 1/2" strapping at a maximum spac ing of 9" for insulation diameter greater than 6" and up to 24". Use 3/4" strapping at a maximum spacing of 12" for insulation diameter greater than 24". co L001178 * SL318/196 Page 2 LAM021341 CEA 3324 McKee LC-4951 SYSTEM 9XX RIGID MINERAL FIBER (continued) Spec 15K-9 3.5.3 Components Apply membrane reinforced mastic to in line pipe components, pumps, instruments and special fittings. Installation of mastic barrier shall be uniform with reinforcement cloth embeded into wet mastic. Provide a 2" minimum lap at joints. The minimum dry-film thickness of the mastic barrier shall be as specified in the materials specifications. Apply sealer at joints and openings in the jacket for complete weatherproofing in outdoor and indoor seirvice. 3.5.4 Vessels Pre-cut the metal sheets to fit snugly around protrusion and fittings. Apply the jacket to the insu lated surface to obtain a snug smooth fit. Circumfer ential and longitudinal metal joints shall be lapped a minimum of 2". Metal laps over the mastic membrane barrier shall be lapped a minimum of 4". Position the laps to provide maximum protection against wind, blow ing rain and water cleaning operations. For vertical vessels where three or more sheets are unsupported, use "Z" clips spaced at 3' centers around the perimeter. Secure the jacket in place with 3/4" strapping maximum spacing of 12". Apply the mastic barrier to insulated vessel heads and other insulated surfaces as specified. Apply a uniform film of mastic to the surface and embed reinforcement cloth into the wet mastic. Apply additional mastic to the entire membrane surface to make a smooth wrinkle free surface. Provide a 2" minimum lap at joints. The minimum dry-film thickness of the mastic barrier shall be as specified in the materials specifications. Application details are shown in K11.4 STD 80. Apply sealer at joints and openings in the jacket for complete weather proofing in outdoor and indoor service. END OF SPEC 15K-9 16814 i.001179 SL318/197 LAM021342 Page 3 n rH cH