Mr. Arthur P. Mueller Research Division Philip Carey Manufacturing Company 320 South Wayne Avenue
Cincinnati# Ohio 45215
Dear Mr. Mueller;
We have completed our analyses of samples of air taken during fabrication of Carey Temp insulation at the Union'Carbide Plant inCharleston#' West Virginia. I do not know if you wish to have a formal report# complete with recommendations# etc., for methods of control of dust. Unless Z hear otherwise# Z will assume that this letter will suffice.
X do not feel it necessary to describe to you the conditions under which these samples were taken# since you were present during the entire operation. All of the impinger samples were breathing zone samples collected directly below, the face of the operator. These samples are representative of an individual's exposure to the dust produced at the operation in question.
The impinger samples numbered 1 through 3 were collected during one "run#" whereas numbers 4 through 6 were taken during the second cutting operation. The electrostatic precipitator samples were located near the saw table and could not be as representative of breathing zone samples as are the impinger samples. Zn addi tion# a high volume air sampler was used to collect cust from the air during the total period of time we were there. This sample naturally includes some down-time.
The samples were analyzed by standard procedures. A sample of
dust collected with the high volume air .sampler was prepared
for examination by X-ray diffraction to determine the per cent
of crystalline free silica and asbestos in the airborne dust.
The X-ray diffraction pattern failed to indicate the presence of
crystalline material in the dust. The probable limit of detection
by X-ray diffraction for asbestos or quartz in untreated samples
is approximately 5 per cent for each material.
j
Hr. Arthur P. Mueller Philip Carey Manufacturing Company
January 2, 1967, continued
-2-
Microscopic examination of the samples of dust indicated the presence of some fibers, but it was not always possible to j . differentiate between glass fibers or asbestos fibers. As you' . are aware, the threshold limit value for asbestos is 5 million . * ' particles per cubic foot of air and for inert or nuisance particu lates this value is raised to 50 mppcf or 15 mg/m^, whichever is the smaller (source: Threshold Limit Values for 1967, ACGIH). Since asbestos is known to be an ingredient of the parent material, siy personal recommendation would be to use the lower value even though the analysis indicated that the dust contained less than 5 per cent asbestos.
The results of the sampling are given in the attached table. If additional information is required, please do not hesitate to let me know. Also enclosed is a statement of charges involved, indluding charges for analyses incurred by the Kettering Laboratory. Please make the check payable directly to me personally for the full amount and Z will reimburse the Laboratory.
Sincerely yours.
JOPsegm Enclosures
J. 0. Pierce, Sc.D. Assistant Professor of Environmental Health.