Document rpJqnR2NYox7b2Vyo6vd7Yk6q
MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST
Inspection Date(s): Time: Weather Conditions: Media/Program:
2/6/2023
Entry: 2:20 PM (EST)
Exit: 3:30 PM (EST)
Cloudy with temperatures of approximately 46 F
Water - CWA 301, 402 - Industrial SW/NEC
Operator Name: Facility or Site Name: Permit ID or Tracking #:
SIC Code:
Facility Address: (city, state, zip code) Geographic Coordinates: Mailing address: (city, state, zip code) County: Regular Days/Hours of Operation: # of Employees at location: Size of Facility (in acres): Receiving Water(s): Date facility est. @ location:
Nolt Services LLC Nolt Services LLC Unpermitted at the time of the inspection 4953 - Refuse Systems The Facility representative was unsure of the Facility's SIC code. The SIC code was inferred by the Inspector based on the industrial activities occurring at the time of the inspection. 728 Rettew Mill Road Lititz, PA 17543 40.187604, -76.208436 728 Rettew Mill Road Lititz, PA 17543 Lancaster
Monday - Friday, 6:00 AM - 6:00 PM 5 full time Approximately 66 acres - This includes the whole farm, not just the observed industrial areas Meadow Run Facility representative stated the Facility commenced operations in 2006
Onsite Representatives: Name: Nelson Nolt
Authorized Official:
Name: Nelson Nolt
Title: Owner
Email: nelson@noltservices.com Contacted? Yes No
Title: Owner
Email: nelson@noltservices.com
Phone: (717) 7381066
Phone: (717) 7381066
Inspector(s): Taylor Fontaine (PG Environmental)
Sean Ireland (U.S. EPA Headquarters)
Title: Inspector Title: Inspector
Ivy Koberlein (U.S. EPA Headquarters) Title: Inspector
Phone: (703) 9561977 Phone: (202) 5642923 Phone: (202) 5642549
Page 1 of 6
MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST Nolt Services LLC Stormwater
Inspection Date: February 6, 2023
Monica Crosby (U.S. EPA Region III) Inspection Report Author: Name: Taylor Fontaine
Supervisor Review: Name: Jessica Duffy
Title: Inspector Signature:
Phone: (410) 3052930
Date: 3/30/2023
Signature: JESSICA DUFFY Date: 2023.04.17 09:19:22 -04'00' Digitally signed by JESSICA DUFFY Date: 4/17/23
SECTION I - INTRODUCTION
Purpose of the Inspection
The purpose of the inspection was to determine compliance with the industrial stormwater requirements under 301 and 402(p) of the Clean Water Act (CWA) and its implementing regulations found at 40 CFR Part 122.26. The inspection was unannounced and consisted of interviewing Facility representatives, recording field observations, and taking photographs to document site conditions throughout the Facility at the time of the inspection.
Opening Conference
1) On February 6, 2023, U.S. Environmental Protection Agency (EPA) contractor, PG Environmental, conducted an unpermitted industrial facility stormwater inspection at Nolt Services LLC located in Lititz, Pennsylvania (Facility). Taylor Fontaine of PG Environmental, Sean Ireland of U.S. EPA Headquarters (EPA HQ), Ivy Koberlein of EPA HQ, and Monica Crosby of EPA Region III (collectively the EPA Inspection Team) met with the Facility representative. Mr. Taylor Fontaine displayed his CWA credentials, and the EPA Inspection Team conducted an opening conference. The EPA Inspection Team explained the purpose of the inspection was to document the facility's industrial activity and any obligations to apply for a National Pollutant Discharge Elimination System (NPDES) Permit (Permit). At the time of the inspection, the Facility did not have coverage under a Permit.
Weather conditions at the time of the inspection were cloudy with temperatures of approximately 46 F. There was no precipitation during the inspection. According to precipitation data from the National Oceanic and Atmospheric Administration (NOAA)1, the Lititz, Pennsylvania area received no rain the day before the inspection.
2) Credentials presented to: Nelson Nolt - Owner ______________________________
3) Facility acknowledged receiving previous outreach materials or correspondence on Permit requirements? Yes No
1Source: NOAA National Climatic Data Center (http://www.ncdc.noaa.gov/).
Page 2 of 6
MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST Nolt Services LLC Stormwater
Inspection Date: February 6, 2023
According to the Facility representative, the Facility is a permitted septage transfer facility and provided the Septage Transfer Facility Permit number (#101681) with the Pennsylvania Department of Environmental Protection (PADEP). However, the Facility did not have an NPDES stormwater permit at the time of the inspection.
4) Facility has been individually notified by Permit authority or EPA that it is subject to stormwater requirements? Yes No
FACILITY'S OPERATION & PRODUCT DESCRIPTION
The Facility was comprised of approximately 66 acres located on Rettew Mill Rd in the City of Lititz, Pennsylvania. The acreage includes a working farm, predominantly cropland, as well as the industrial operations described below. The Facility is bordered by private farmland on all sides. The Facility includes several buildings used for materials and equipment storage.
According to the Facility representative, the Facility serves as an on-lot sewage disposal, treatment, and transfer facility. The representative stated the Facility receives and treats manure, liquid waste from food processing facilities (e.g. food processing washout), and biosolids. These materials are sorted and stored/treated in the following concrete in-ground treatment tanks, as identified by the Facility representative. Once the products are ready, they are pumped out of the tanks via vacuum trucks or lagoon pumps. The Facility representative stated that treated waste is then utilized for land application/fertilizer. The tanks below were observed during the inspection:
P1 - 396,000 - gallon tank designed to store and treat waste via lime stabilization or other treatment methods.
P2 - 252,000 - gallon tank designed to store and treat manure. P3 - 1,353,600 - gallon tank designed to store and treat biosolids and food processing waste.
The EPA Inspection Team observed that all the identified tanks above were uncovered and exposed to stormwater at the time of the inspection.
Other industrial facilities owned/operated by same business entity? Yes No
SECTION II - OBSERVATIONS
SITE EVALUATION
Pollutant Sources
Observations
Loading/Unloading Operations
Industrial Manufacturing/ Processing Operations
Materials and products are shipped in and out via semi-trucks.
According to the Facility representative, Facility industrial operations (waste storage and treatment) occur entirely outdoors and are exposed to stormwater.
Page 3 of 6
MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST Nolt Services LLC Stormwater
Inspection Date: February 6, 2023
Industrial Machinery & Equipment Storage
Storage of Industrial Materials or Products
Liquid Storage (e.g., Tanks, Liquid Storage Drums)
SITE EVALUATION
The EPA Inspection Team observed outside uncovered storage areas for vehicles and Facility equipment (refer to Appendix B, Photographs DSCN5017 and DSCN5068). The outside storage areas did not have any cover.
The Facility representative stated that the Facility has its own trucks, but also receives septage/biosolids materials directly from customers/contractors via their respective vehicles.
The industrial products (i.e. septage/biosolids materials) are stored entirely in the three (3) concrete in-ground treatment tanks listed above in the Facility's Operation & Product Description section of this report (refer to Appendix B, Photographs DSCN5018 - DSCN5021). The EPA Inspection Team observed six (6) 1,000-gallon diesel tanks used for fueling onsite equipment and vehicles (refer to Appendix B, Photographs DSCN5039, DSCN5040, and DSCN5057. It was unclear if the tanks were double walled, but they were covered by a canvas awning and were within a concrete secondary containment structure. It is unclear whether the secondary containment structure was large enough for the oil stored in that area.
Waste Storage/Disposal Areas (solid and/or hazardous)
The EPA Inspection Team observed one (1) dumpster with a closed lid used for general waste located adjacent to the fuel storage area (refer to Appendix B, Photograph DSCN5057).
Waste Treatment Facilities The Facility serves as an on-lot sewage disposal, treatment, and transfer (e.g., Pretreatment Systems) facility.
Fueling Stations/Equipment As stated above in the Liquid Storage section of the checklist, the EPA Inspection Team observed six (6) 1,000-gallon diesel tanks used for
Maintenance Areas &
fueling onsite equipment and vehicles (refer to Appendix B,
Cleaning Areas
Photographs DSCN5039, DSCN5040, and DSCN5057).
Sediment & Erosion Controls
The EPA Inspection Team did not observe any sediment and erosion controls at the time of the inspection.
Spills/Leaks Handling
Outside Shelters
The EPA Inspection Team did not observe spill containment measures or materials (e.g., spill kits or absorbents) at the Facility.
Temporary (Date Established___________________) Permanent
One outside shelter at the Facility is used to cover the six (6) 1,000-gallon diesel tanks.
Page 4 of 6
MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST Nolt Services LLC Stormwater
Inspection Date: February 6, 2023
SITE EVALUATION
Evidence of non-stormwater
sources/discharges (allowable if permitted
None observed.
under the Permit)?
Evidence of process wastewater sources/discharges?
The EPA Inspection Team did not observe any evidence of process wastewater sources/discharge.
OUTFALL, STORMWATER DISCHARGE & RECEIVING WATER OBSERVATIONS
Number and description of each potential Stormwater Discharge Point from the Facility
Meadow Run flows southwest through the Western portion of the Facility. Due to the topography, the EPA Inspection Team observed several points of potential discharge adjacent to Tank P2 and the maintenance/storage building. Stormwater in this area appears it would flow north from these areas towards Meadow Run located approximately 25 feet north of the Facility (refer to Appendix B, Photographs DSCN5065 and DSCN5066).
Evidence of pollutants migrating offsite (stains, deposits, ponding) at discharge points, into Receiving Waters or in MS4
The EPA Inspection Team did not observe any pollutants in Meadow
Run; however, approximately six cattle were located in a vegetated area of approximately
3,000 square feet at the very beginning to Meadows Run.
Evidence of Nonstormwater Discharges leaving site (authorized or unauthorized)
Description of general gradients/slopes onsite, all apparent discharge points, and discharge pathway from Facility to Receiving Water or MS4 (storm drains, channel, swale, ditches, driveway, pipes, & etc.)
None observed.
The EPA Inspection Team observed that stormwater from the middle and north portions of the Facility would flow northward towards Meadow Run (refer to Appendix B, Photographs DSCN5022DSCN5026, and DSCN5061-DSCN5067). Stormwater from the south portion of the Facility would flow north across a grass field. There were no drains or stormwater conveyance pipes observed during the inspection, other than the outlet from a pipe that conveyed stormwater from a residential neighborhood located approximately 3,000 feet east of the operations facility.
SECTION III - AREAS OF CONCERN
1) The EPA Inspection Team observed the Facility conducts refuse management operation concrete manufacturing at the Facility, an industrial activity classified under SIC 4953 - Refuse Systems.
Page 5 of 6
MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST Nolt Services LLC Stormwater
Inspection Date: February 6, 2023
a. Businesses classified under SIC Code 4953 are regulated under 40 C.F.R. 122.26 for stormwater discharges associated with industrial activity.
b. Waste treatment operations occur outside and are exposed to stormwater. c. The Facility did not have coverage under a Permit at the time of the inspection. 2) The EPA Inspection Team observed several areas at the Facility adjacent to the tanks where there was evidence of spillage on the gravel and paved surfaces (refer to Appendix B, Photographs DSCN5019, DSCN5020, DSCN5034-DSCN5038, DSCN5043DSCN5047, DSCN5054, DSCN5055, DSCN5059, and DSCN5060). In some instances, it was unclear if the observed spillage was waste materials or petroleum based. Due to the topography, there was the potential for stormwater would be directed toward the headwaters of Meadow Run. SECTION IV - CLOSING CONFERENCE After the site walk, the EPA Inspection Team met with the Facility representative from Nolt Services LLC for a closing conference and shared preliminary observations. The EPA Inspection Team reiterated that all preliminary observations discussed were not compliance determinations; however, it was observed there was the potential for pollutants to be discharged from the facility. Any and all preliminary observations shared were subject to further investigation by the EPA Inspection Team. Additional observations may be contained in this inspection report that were not identified at the time of the closing conference. The inspection concluded at approximately 3:30 PM (EST). SECTION V - LIST OF APPENDICES Appendix A - Aerial Map Appendix B - Photograph Log
Page 6 of 6
Appendix A. Aerial Map
Clean Water Act Inspection Nolt Services LLC.
Inspection Date: February 6, 2023
Appendix A. Aerial Map Multi-Sector General Permit Non-Filer Inspection
Page 1 of 2
Nolt Services LLC Inspection Date: February 6, 2023
Legend Flow Direction Water Body Facility Boundary Outfall Point
P2 tank
P3 tank
Fuel storage P1 tank
Figure 1. Aerial image of Nolt Services LLC from Google Maps (imagery dated 2023). Meadow Run flows from the east to the west and is located on the north side of the Facility.
Appendix A. Aerial Map Multi-Sector General Permit Non-Filer Inspection
Page 2 of 2
Nolt Services LLC Inspection Date: February 6, 2023
Appendix B. Photograph Log
Clean Water ActInspection Nolt Services LLC.
Inspection Date: February 6, 2023
* Disclaimer: All photos were taken on 2/6/2023. Some photographs do not contain GPS coordinates.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 1 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Facing northeast of Facility machinery storage with Meadows Run flowing right to left just beyond the gravel lot.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 2 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Facing northeast, of Tank P2, a 252,000 - gallon tank designed to store and treat manure located in the north area of the Facility.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 3 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Tank P2, note the spillage in front of the tank.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 4 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Tank P2, note the additional spillage in front of the tank
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 5 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Facility equipment by Tank P2.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 6 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Meadow Run section that is piped flowing from east to west from a residential neighborhood 3,000 feet to the east along the Facility's north boundary.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 7 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Meadow Run viewed from Tank P2.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 8 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Meadow Run.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 9 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Area upgradient of Meadow Run.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 10 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Additional view of Meadow Run with outlet from pipe coming from residential neighborhood located 3,000 feet to the east.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 11 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Tank P3, a 1,353,600-gallon tank designed to store and treat biosolids and food processing waste.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 12 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Tank P3.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 13 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Tank P3.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 14 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Furnace adjacent to Tank P3.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 15 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Connection pipe to Tank P3.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 16 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Connection pipes for Tank P3.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 17 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Gate for Tank P3.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 18 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Spillage staining adjacent to Tank P3.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 19 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Closer view of the spillage staining as shown in Photograph DSCN5034.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 20 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Spillage staining from the connection pipes to Tank P3.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 21 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Spillage staining adjacent to Tank P3.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 22 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Spillage staining adjacent to Tank P3.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 23 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description
Six (6) 1,000-gallon diesel tanks used for fueling onsite equipment and vehicles under a canvas structure.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 24 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description
Front view of the six (6) 1,000-gallon diesel tanks used for fueling onsite equipment and vehicles under a canvas structure.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 25 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description 750-gallon fuel container for farm use, located in front of two silos.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 26 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Upgradient view of Tank P3.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 27 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Lime and unknown spillage adjacent to Tank P1. P1 stores and treats waste via lime stabilization.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 28 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Lime and unknown spillage adjacent to Tank P1.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 29 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Lime and unknown spillage adjacent to Tank P1.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 30 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Spillage on the concrete area adjacent to Tank P1.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 31 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Spillage on the concrete area adjacent to Tank P1.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 32 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Solids and grit removal machine adjacent to Tank P1.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 33 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Pumping equipment for Tank P1.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 34 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Solids and grit removal machine adjacent to Tank P1.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 35 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Tank P1 in the south area of the Facility.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 36 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Slope leading away from Tank P1.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 37 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Solids and grit removal machine adjacent to Tank P1.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 38 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Spillage on the concrete surface adjacent to Tank P1.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 39 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description View, facing southwest, of spilled lime on the ground adjacent to Tank P1.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 40 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Approximate 750-gallon fuel container for farm use.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 41 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description View, facing northeast, of Tank P2.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 42 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Spillage on the ground adjacent to Tank P2.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 43 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Spillage on the ground adjacent to Tank P2.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 44 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Downgradient view of Meadow Run.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 45 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Upgradient view of Meadow Run to the north of a small white shelter.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 46 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Upgradient view of Meadow Run.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 47 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Downgradient view of Meadow Run flowing from the east to the west.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 48 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Direction of sloping terrain from the area adjacent to Tank P2 towards Meadow Run.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 49 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Direction of sloping terrain from the area adjacent to Tank P2 towards Meadow Run.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 50 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description Meadow Run headwaters and Facility trucking equipment.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 51 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine
Description View of Facility trucking equipment.
Appendix B. Photograph Log Multi-Sector General Permit NonFiler Inspection
Page 52 of 52
Nolt Services LLC Inspection Date: February 6, 2023 Photographs taken by Taylor Fontaine