?--CUSTOMER PROBLEM REPORT {^) PLAINTIFF'S EXHIBIT QATE PROBLEM REPCTrTED AND RECEIVED September 2, 1975 SERVICE REFERENCE NUMBER USE THIS NUMBER TO IDENTIFY ALL REPORTS AND CORRESPONDENCE RELATIVE TO THIS SERVICE, DATE OF REPORT: September 3, 1975 REGION STATE YEAR , cc C 75 NUMBER 39G CUSTOMER-CONSUMER INFORMATION CONTRACTOR * Bill Ledbetter Drywall PROJECT .. Horn Construction PRODUCT INFORMATION SAMPLE INFORMATION product K-SpraY/Pr^Mix^Tggg^ng.^ SAMPLE 1.0. * OTHER INFO. AntiochPLANT ORIGIN Aug 8-1 & Aug 8-2 DATE OF SHIPMENT- August 11.1973 Non-asbestos topping codes CAR-TRUCK CARRIER 1*0.- KQC SHIPMENT-ORIGIN. AtltjOCh 06-3076 INV./SLS. ORDER NO. SHIPPING TAG NO. DATE OP SHIPMENT BILLING--------------------------------- CARRIER KGC CHECK IF TECHNICAL ENGINEER ASSISTANCE IS.REQUJRED. YES NO x STATE SPECIFIC PROBLEM - BE SPECIFIC - GIVE COMPLETE DETAILS: Bill Ledbetter reauested assistance on the following problem. Butt loints in the ceilings of a recently sprayed model home were showing up through the acoustic spray. -' .- ** * * * y` . -' .^ . DISTRIBUTION: SENIOR VICE PRESIDENT, SALES ft MARKETING SENIOR VICE PRESIDENT. MANUFACTURING ft DISTRIBUTION - MANAGER OF MARKETING 4 nager, field marketing services NACER. CORPORATE ENGINEERING ft DEVELOPMENT ` MANAGER. FIELD TECHNICAL SERVICES t MANAGER. SPECIAL PRODUCTS ASST. TO VP. MANUFACTURING \ DISTRIBUTION GENERAL PRODUCTION MANAGER name____Wa-.IL Hopper . , MANAGER. PROCESS ft CONTROL PnLaAmNeT_M_ANMAuGhErR______. _______ TECHNICAL ENGINEER REGIONAL SALESwMANAGER namf B. X Burpny OlV. MGR.. MARKETING SERVICES NAMr C.Cutler__________ Form 61?(4/7S) D.B. Gillease/C.B. La Faygtfte ORIGINATOR OF REWIRE ` D1ST7AREA SALES MANAGER name D L. Cstrpsnt^r SUPERVISOR. QUALITY .CONTROL H. L. Wexghtman SUPERVISOR. PROCESS ENGINEER RESEARCH OR CONCRETE LAB CHIEF CHEMIST SALESMAN, NAVE. P, B. Gillease OTHERS* P* A.Hawkins R.G.Klein G.A.MacCorkle C.B.LaFayette TECHNICAL ENGINEER C "JTOMER PROBLEM REPORT REPLY. .. (CPRR) DATE PROBLEM RECEIVED DATE OF AND REPORTED September 2, 1975 reply September 8, 1975 SERVICE REFERENCE NUMBER -SAME ASCPR REGION SERVICE CUSTOMER-CONSUMER INFORMATION m productNon-asbegrns Premix p^nt Antioch ^PP3-^- cc STATE YEAR f NUMBER c. 75 i lar: DEALER CONTRACTOR Butch Hollingsworth project Neroly Ranc{, Development, Saddle D Oakley DETAIL. SERVICE EFFECTED - SAMPLE TESTS - FACTORS RESPONSIBLE FOR PROBLEM - CONCLUSIONS The custom built home -in the above mentioned development was inspected on September 5, 1975. A number of dark appearing areas over the cape and butt joints were noted in the garage and northeast bedroom of the house. The dark appearing areas extended approximately three inches on each side of the joints. A definite pattern difference in the K-Spray ceiling texture was noted over the joint area. The K-Spray applied over the non-asbestos topping compound was rougher in texture, had higher than normal concentratic of polystyrene bead and less carrier liquid than that shot over the board. It is believe that this texture variation contributes to the discoloration over the topped joint. It i further felt th3 condition is created by the rapid drying out of the topping compound (in this case coded 8/7, 8, or 12/75) which-subsequently absorbs more than the normal amount of the acoustic carrier liquid and hence leaves the rough textured pattern over th joints, ____________________________________________________________________________________________________ The remainder of the ceilings in the house were uniform in ceiling texture color and pattern. RECOMMENDATIONS TO PREVENT FURTHER RECURRENCES - INDICATE PERSONNEL TO WHOM RECOMMENDATIONS WERE MADE RESPONSIBILITY ASSESSMENT - CREDITS- CLAIMS - MATERIAL REPLACED This is a KC&GC responsibility; a reasonable claim for respraying the garage and the northeast bedroom should be paid.________________________________________________________________________ DISTRIBUTION: SENIOR VICE PRESIDENT. . SAl.CS ft MARKETING - # SCNIOR Vice PRESIDENT, MANUFACTURING & DISTRIBUTION ^lANACCR OF MARKETING MANAGER. FIELD MARKETING SERVICES MANAGER. CORPORATE ENGINEERING A DEVELOPMENT MANAGER. FIELD TECHNICAL SERVICES MANAGER. SPECIAL PROOUCTS ASST. TO VP* MANUFACTURING * DISTRIBUTION GENERAL PRODUCTION MANAGER HAur w. D. Hopper___ MANAGER, PROCESS A CONTROL PLANT MANAGER ,,, nam c* TC i, Muhr ___ TECHNICAL ENGINEER OIV. MGR.. MAftKETtNG SERVICES namc * CCutier________ OIST.JARCAY^SSAI?Vrosv NAME SUPERVISOR u i* weis SUPERVISODR. PROCESS ENGINEER!ING RESEARCH OR CONCRETE LAB CHYEP CHEMIST SALESMAN C, *BLaFayette NAME. others: P.A*Hawkins R.G*Klein G.A.MacCorkle , 1 CUSTOMER PROBLEM REPORT REPLY (CPRR) DATE PROBLEM RECEIVED DATE OF AND REPORTED 8/06/75-8/08/75 REPLY SERVICE REFERENCE NUMBER - SAME AS CPR SERVICE CUSTOMER-CONSUMER INFORMATION - Septemt?er 8. 1975 product Dual Purpose Jt Cmpd plant Santa Ana _ REGION J STATE YEAR NUMBER SC 1 ___ C_ ___ 1975 ____642 DEALER NORWAL, INC. Canoaa Park. CA CONTRACTOR Norwal. Inc. PROJECT Various DETAIL SERVICE EFFECTED * SAMPLE TESTS - FACTORS RESPONSIBLE FOR PROBLEM - CONCLUSIONS PRODUCT: Joint Compound (Dual Purpose Gold) Non-asbestos_________ DATE OF SHIPMENT: 7/28/75 & 7/31/75 (Manufactured July 22, 1975), Customer complained that his men had refused to use our "new formula'* .joint compound and had walked off the job. The following observations were made by Don Johnson & Joe Lafayette:; __________ 1. Hud stiff, hard to pump (screens had to be removed)_____________________ __________ 2. Tape would slip from walls_______________________________________________ 3. Jello-like _________________________________________________________ RECOMMENDATIONS TO PREVENT FURTHER RECURRENCES - INDICATE PERSONNEL TO WHOM RECOMMENDATIONS WERE MADE The Santa Ana plant resumed shipping the asbestos based Dual Purpose Joint Compound which has good customer acceptance. A new formula non-asbestos product is presently in the field at selected customers and specially labeled, temporarily. E & D is following rlnsply for arrpptanro______________________________________________~______________________ RESPONSIBILITY ASSESSMENT CREDITS- CLAIMS - MATERIAL REPLACED This complaint was justified and a KC&G responsiblity. DISTRIBUTION: SCNiOft VICE PRESIDENT. SAUS k MARKETING SENIOR VICE PRESIDENT. MANUFACTURING & DISTRIBUTION f MANAGER OF MARKETING MANAGER. FIELD MARKETING SERVICES ASST. TO VP. MANUFACTURING A DISTRIBUTION GENERA NAME UR^uciSrACER MANAGER. FROCESS A CONTROL PLANT M NAME. James MANAGER. CORPORATE ENGINEERING A DEVELOPMENT TECHNICAL ENGINEER regionAR?Ags nageffiSlster MANAGER. FIELD TECHNICAL. MANAGER. SPECIAL PRODUCTS DIV. MGR.. MARKETING SERRVVtCES ame J- S. Mcffahev H. Nicoll SERVICE EFFECTED BY DtST./AR1EEAA SALES MANAGER NAME. "n, R Johnson SUPERVISOR, QUALITY CONTROL SUPERVISOR, PROCESS ENGINEERING RESEARCH OR CONCRETE LAB CHIEF CHEMIST ?SALE5M NAME Schell inoen others: Hawkins r.G-Klein G. A. MacCorkle 4ClA MANAGER. FlELO TECHNICAL SERVIctS" 0li MMcK t'MObLLivi bcrurvi iiuti i v (\| * DAT-- .ROBLEM RECEIVED : ANT REPORTED 9/2/75 DATE OF reply September 8, 1975 ` REFERENCE NUMBER - SAME AS CPR ' REQION ' ' RVICE CUSTOMER-CONSUMER INFORMATION | /#C 1 j product Non-asbestos.Premix-Top- PLANT Antioch Pln8 compouft- STATE .... C YEAR 75 I / NU.VBER 39G ALE R } CONTRACTOR . Bill Ledbetter Drywall i______ DETAIL SERVICE EFFECTEO * SAMPLE TESTS * FACTORS RESPONSIBLE FOR PROBLEM - CONCLUSIONS FROJECTgmoj.ecree >pracj.^ Modesto, Hern Construct!- .Investigation revealed that all butt joints were in fact showing thru the acoustic * because of a difference in the material pattern covering the joints. Further investiga tion revealed that the following houses in the Smoketree tract vere defective. House_______ | numbers 1196, 1200 thru 1206, 1212, 1213 and 1246. Also, one house on Patterson Road in * j Riverbank which was sprayed at the same time as the aforementioned houses ____________________ IInvestigation revealed that the defective houses were serviced with nonasbestos j premix topping dated Aug 8-1 and Aug 8-2 Several other houses were done at the same j time with asbestos topping and these houses were in excellent shape* i -. RECOMMENDATIONS TO PREVENT FURTHER RECURRENCES - INDICATE PERSONNEL TO WHOM RECOMMENDATIONS WERE MADE - ' \ -c 'l i t ~/3V p-^ - ' c-jS tr- ^- RESPONSIBILITY ASSESSMENT - CREDITS - CLAIMS - MATERIAL REPLACED T.t appears that the non-asbestos topping compound as presently manufactured is unacceptable for use when applied to ceilincs prior to application of K-Spray ceiling texture. This is a KC&GC responsibility; reasonable claims for resprayinE the above mentioned homes should be processed. DISTRIBUTION: SENIOR VICE PRESIDENT* SALES 4WARKCTINC SENIOR VICE PRESIDENT* * MANUFACTURING & DISTRIBUTION ASST. TO VP* *' MANUFACTURING ft DISTRIBUTION GENERAL PRODUCTION MANAGER frf.name___________ Dv Hopper______ MANAGER. PROCESS ft CONTROL . vi ANAGER OF MARKETING NAGER* FIELD MARKETING SERVICES MANAGER. CORPORATE ENGINEERING ft DEVELOPMENT * MANAGER, FIELD TECHNICAL SERVICES Manager, special products c. B. PLANT MANAGER, .. , WAMr K. L. Muhr_________________ TECHNICAL ENGINEER REGIONAL. SALES MANAGER 'name B- J. Murphv___=-- OIV. MGR.. MARKETING SERVICES name___________C. Cutler LaFavette/ ' FORM M* f.t `7*| SERVICE EFFECTED BY \ OIST./AREAi ^SAALLEES MM#ANAGER NAME. D. 'L. Carpenter SUPERVISOR. QUALITY CONTROL ' SUPERVISOS.VR%CES^E3g INCEH1NG . RESEARCH OR CONCRETE fcAB CHIEF CHEMIST SALESMAN p B .Gm&ase. . othersP.A.Hawkins R.G.Klein G.A.MacCorkle C.B.LaFayette [Ul MANAGER. FIELO TECHNICAL SERVICES wuu luwi i DATE PROBLEM REPQRTEP AND RECEIVED 11/20/75 SERVICE REFERENCE NUMBER USE THIS NUMBER TO IDENTIFY ALL REPORTS AND correspondence relative to this service. DATE OF REPORT: 11/20/75 REGION STATE YEAR Eastern Pa. 1975 NUMB?3v 9w E-JJ9 CUSTOMER-CONSUMER INFORMATION DEALER T. House & Sons Beaver FalI. Penna. `CONTRACTOR ____________PRODUCT INFORMATION r---------- Premix <$, Topping PLANT ORIGIN. 10/9/75 DATE OF SHIPMENT. 10/9/75 Del CAR-TRUCK CARRIER I.D.------------- CAV SAMPLE INFORMATION SAMPLE f.O. A OTHER INFO. SHIPPING TAG NO. SHIPMENT-ORIGIN .......................... -- INV./SLS. ORDER NO--------0^- 1 487_ DATE OF SHIPMENT BILLING, . hanufacturinc date CHECK IF TECHNICAL ENGINEER ASSISTANCE IS REQUIRED. YES STATE SPECIFIC PROBLEM - BE SPECIFIC - GIVE COMPLETE DETAILS: NO Th i i <; npw a;hps+nF>^ f rpp prnrlnr+. Ms+prisl ic +h i rk anrt no adhpcivp qnatf-ty. When miypH with drill It qot thicker and qummy. When applied to ioint it dries tojfast and has tendency to bubble and flake. Customer burnt out one drill trylnq to mix. Both the beddina and topping are actinq the same way. 1 have advised customer not to use until lab checks it out Code numbers are bedding 5107 and 1108 - Topping 38-28. Also received same type .of complaint from Dave Price on same material shipped on same day. Sample being returned to v plant on our truck this day. lease advise me as to what customer should do with material.* He has deducted from his invoice for this material. . '. i-c -H -c .Y DISTRIBUTION: SENIOR VICE PRESIDENT. SALES fc MARKETING SENIOR V#ICE PRESIDENT. MANUFACTURING A DISTRIBUTION MANAGER OF MARKETING * tMANAGER. FIELD MARKETING SERVICES NACER. CORPORATE SNEERING A DEVELOPMENT MANACER. FIELD TECHNICAL SERVICES ( MANAGER. SPECIAL PRODUCTS J, ASST. TO VP. MANUFACTURING A DISTRIBUTION GENERAL PRODUCTION MANAGER ___name W.D. Hopper_______ MAWACEU,j>RJCEJJN|^OHTBOL. TECHNICAL. ENGINEER ,. wavromatis REGIONAL. SALES.MANAGER name A.v. Oaoong OIV. MGR MARKETING SERVICES name____R-H- .Tnmpq ______________ CoK Foim 612 (4/75) ORIGINATOR OF REPORT DIST./AREA SALES MANAGER NAME_______________________________________ SUPERVISOR. QUALITY CONTROL SUPERVISOR, reseaSci? 6R^5fe RCTE LAB CHIEF CHEMIST SALESMAN NAMF J. Cox othebsi- P.A. Hawkins )R.E. Dixon 'R.G. Klein G.A. MacCorkl TECHNICAL ENGINEER 333