: 1953 Guide
EQUIPMENT, AND INSTALLATION METHODS
Convector with Metallic Resistors
Standard heating units for wall mounting, of either recessed or surface type, are made with resistors of incandescent bafe-wire or low-temperature (black) types and the:general construction already described, A metai inner liner or reflector usually placed between resistors and casing pro vides a secondary air'passage to promote circulation and reduce casing surface temperature atr the rear. Depending on ratio of horizontal to
Table 1. Principal Types op Electric House. Heating Systems
A. Radiators, Convectors, Unit Heaters--Built-In and Portable 1. Metallic resistor, high- or low-temperature 2. Glass unit with metal frame 3. Baseboard-type resistor 4. Resistor with fan,' including unit heater 5. Resistor with focusing radiation reflector 6. Steam radiator with immersion electric element
B. Panel-Type Installations 1. Ceiling panel a. Rigid composite panels containing electrically conductive rubber b. Flexible composite sheets containing embedded metallic filaments or con ductive rubber c. Electric conductors embedded in plaster on lath 2. Wall panel a. Rigid panels, as for ceilings , b. Flexible sheets, as for ceilings
m3. Floor panel a. Electric conductors embedded in concrete slab
. . b. Soil heating cable under ceramic tile C. . Central Hot-Water Systems
, 1- Water from electric heater, pumped to radiators dr convectors.in rooms . . . 2. Same, with thermal storage for off-peak operation
3. Fuel-fired boiler converted to electricity D. Central Warm-Air Systems
I. Resistance-element bank in housing or air duct ; . 2. Fuel-fired furnace converted to electricity E. Heat-Pump Systems
1. Warm-air distribution through ducts, like D-l , 2. Hot-water distribution, like C-l or 2
3. Radiant panels, like B-l or 2, but with embedded tubing to act as refrigerant condenser
vertical dimension, pattern of face grille, and arrangement of resistora and deflector, the convection heat delivery constitutes between 40 and- 60 percent of total output.
Ratings usually are from 1000 to 8000 watts (3400 to 27,300 Btu per hr) with some models down to 500 and up to 15,000 watts. Voltages are the standardized values between 110 and 240. Similar models equipped also with air circulation fans of axial type, are available; these give con vection heat delivery up to 80 percent. Other types, using the same
Electric Heating
913
components but without a fan, are arranged as floor furnaces'to be installed
between floor joists. A manual switch and thermostat integral with the
unit are optional.
. .
Portable units of the foregoing types, except, floor furnaces, are . ob
tainable with plug-in extension cords, for convenience and occasional ser
vice. Ratings are 500 to 1200 watts at 110 volts.; special models rated up
to 5000 watts are also made, but can be used only on branch circuits having
special wiring and receptacles.
Convector Type Unit
The location of built-in electric heating units of convector type, generally along the exterior walls beneath or alongside windows, is governed by the same principles that determine arrangement of steam and hot-water con vectors, with respect to movement of warm and return air. Positions on interior walls are sometimes permissible, so long as interference from opened doors and from furniture placement is avoided. A thermostat of highsensitivity type and a conveniently located manual switch are recom mended for each unit or at least each room.
Radiant Convector Unit
. Glass electric heating units, sometimes designated as radiant panels, depend on the heating effect produced by passage of current through a thin' Coating of conductive material fused to one face of a panel of j-in. thick special glass. The conductive layer may be sprayed-on aluminum or 'printed metallic oxide patterned to form a grid several thousandths of an inch thick, or fused-on material to give a uniform coating less than 0.0001 in. thick over the entire active face of panel. Normal glass operating temperatures are 300 to'400 F, with maximum permissible temperature around 650 F. Electric wiring connections are made to conductor strips bonded to the panel coating along opposite edges. The panel is supported on insulators within a metal frame which also carries a reflector behind the glass and is arranged to provide space for air circulation. A protective guard prevents accidental contact with the hot glass.
Glass units have standardized ratings, usually 1000 watts, with smaller units extending down to 200 watts, for the common voltages ranging be tween HO and 240 volts. Starting current for some types exceeds running current by 10 and by 50 percent. Frame sizes vary from about 30 x 24 in. for 1000-watt size to 42 x 6 in. for 300-watt baseboard model; frame types are for either recessed or surface mounting. Thermostats integral with the frame assembly are optional. Portable units equipped with plug in extension cords are of similar construction.
Baseboard Type Unit
Metal casing proportioned to resemble and replace the conventional wood baseboard along plastered or masonry walls, Contains 2 or 3 resistors placed horizontally, one above another. These usually are of low-tem perature type, with ratings 80 to 120 watts. (270 to 400 Btu per hr) per linear foot of baseboard unit, at 240 volts. The maximum surface tem perature is 140 to 160 F. The vertical dimension is 6 to 8 in. above floor line, and the projection from face of plaster about 1.5 in. Placement within the room and method of control follow the same principles that apply to hot-water type baseboard installations described in Chapter 23.
Another type of baseboard unit has glass panels 6 to-8 in. high and 30 to 42 in. long, with surface operating temperature kept below 250 F.