Document rp6ymGRqeMjg25YV2VDy2rd4v
VI. TENTATIVE OPERATING INSTRUCTIONS
-
B. CONTINUOUS BLOW TANK
. .
1. Synopsis
Crude Aroclor 1142 is fed continuously from #9
.
. chlorinator to the continuous blow tank. Here
the crude passes over four baffles which
.
divide the blow tank into five compartments.
' In each compartment the crude Aroclor comes in
.
contact with air from the blower. This removes
HC1 and helps improve the quality of the Aroclor
and is the only purpose for the tank. The air
goes out the top of the blow tank to the #1
intermediate storage tank and then to the blow
tank demister tank. From the blow tank the
crude Aroclor goes to the #1 intermediate
-
storage tank. .
2. Equipment
.
.
a. Continuous blow tank (Item 422)
-
b. Blow tank transfer pump (item 423)
-
c. Sutcbilt air blower (item 432)
3. Equipment Function
a.- The function of the continuous blow tank is
.
to receive crude 1142 from #9 chlorinator and
provide a place where air can be sparged into
' the crude to remove HC1.
b. The function of the blow tank-transfer pump is to continuously pump crude 1142 to the #1 intermediate storage tank.
c. The function of the air blcvrer is to blow ambient air into the crude 114-2 to remove HC1.
4. Control Loops, Interlocks, and Alarms
a. Control Loops
*
'
1) Level (LCA-17)
The function of this loop is to control the level
of crude Aroclor in the continuous blow tank and
to activate an alarm if the level should go above
36" or below 12". The only level indication on
this tank is the air gauge on the controller.
Normal level' is 9^ on the gauge: 4# is 12", and
12# is 36"..
'
. '
b. Interlocks - None on this system.
PCB-ARCH-EXT0374451
TENTATIVE OPERATING INSTRUCTIONS B. CONTINUOUS BLOW TANK
c. Alarms ...
.
`
l) High or Low Level in tank. If the air gauge
.
on the controller at the tank hits 12# (36")
or 4# (12"), the alarm will sound and the
light will go on in the telelarm window marked,
.'
"Hi or Low Level, Air Blower Off, Blow Tank".
2) Blower Off - If the air blower motor stops, an alarm will sound and the window marked "Hi or Low Level, Air Blower Off, Blow Tank", will light on the Telelarm panel.
3) Blow Tank Transfer Pump Off - If the blow tank
.
transfer pump motor stops, an alarm will sound
. and the window marked, "Hi or Low Level, Air
. . Blower Off, Blow Tank", will light.
5* Start Up Instructions
a. As soon as there is some naterial in the blow
tank, start the air blower with all valves
open to all five compartments.
b. Align the valves for circulation and start the transfer pump.
c. When the level in the blow tank is high enough to produce a 9# air signal and the continuous chlorinators are feeding into the tank, the valves can be aligned to feed crude to the #1 intermediate storage tank.
6. Normal Operations
During normal operations the following conditions should exist.
a. Transfer pump on arid circulating line open.
b. Blower on, rotameter reading 20-40$, and air going to all five compartments.
c. Tfink level at 9# on the air gauge. d. Temperature on tank should be 150C. to l80C.
PCB-ARCH-EXT0374452
TENTATIVE OPERATING INSTRUCTIONS (contd.)
B. CONTINUOUS BLOW TANK
.
7** Shutdown Instructions
.
a. Emergency
.
1) Shut off transfer pump
2) Close manual valves on feed lines to the
blow tank and 'transfer pump,
.
- 3) Shut off air blower. '
. b. and c. Normal Short Time and Long Time
Close manual valve in feed line to the blow tank.
d. Electrical Power Failure
If a power failure occurs close the manual . valve in the line from #9 chlorinator. '
When power is restored do the following to
. start up:
1) Start circulating pump.
2) Start the city water booster pump and make sure
there is water on jet.
.
3) Start air blower
4) Open manual valve in the line from #9 chlorinator.
8. General Information
a. Keep the blower on to prevent ferric chloride from settling out in the blow tank.
b. If the level float sticks, the tank can run
over or empty without the air gauge changing,
If it runs empty and you are feeding #3 or
. #4 still, the still vacuum will be lost. If
it runs empty and you are feeding the #1 intermediate storage tank, the intermediate
.
storage tank level will fall if the column
is being fed or remain constant if the column
Is not being fed.. If the tank runs over the
air lines to all 5 compartments will be full
of hot crude and will be hot. if jrou touch
them.
.
.
PCB-ARCH-EXT0374453
VI.
TENTATIVE OPERATING INSTRUCTIONS (contd.) B. CONTINUOUS BLOW TANK (contd.)
. 8. General Information (contd.)
.
c. If the tank rims over, the crude will go to
.
. #1 intermediate storage through the air
,
discharge line.
.
. .
. . .
d. The blow tank can be by-passed when charging
a straight take-over still (#3 or #4) but not
when feeding the intermediate storage tank
. with crude to go to the column. Notify
supervision if you are going to by-pass the
blow tank.
9. Critical Control Points
Expected Control Point Reading
Deviation Limit and Effect
Correction
Level
9# Air
5-12# air. Tank Raise or lower level
can run over or 2 times. If it
' empty.
won't control,
notify supervision.
.Air Supply
30 $
.
More than 20$ Make sure globe
, HC1 will not
valves by rotameter
be removed.
are open enough.
. Possible damage Notify supervision
to column. -
if this is not the
problem.
10. Other Control Points
Control Point Expected Reading
Deviation Limit and Effect
Correction
Temperature
l60C.
11. Trouble Shooting
150-l80C. No effect if storage feed is OK.
Check temp, of #9 chlorinator.
**
Symptom
Problem
Cause
Possible Solution
1. Lost vacuum on take-over still.. . .
......
1. Air going from 1. Blow tank 1. By-pass blow tank
blow tank to
is empty.
(notify supervi-
still. '
-
sion).
.
2. Check to see if-
. . level control is
.
hung up. Raise and
.
lower couple times
Allow chlorinators
to fill blow tank
'.
to #9 level & try
-
again. .......
PCB-ARCH-EXT0374454