Document rp5EwX8rrq31dxmnnzbvDynVa

ARCO Mtrin*. Inc. Internal Conaapendanca Oate:. Subject Frwn/Laeatteni Ta/Leeatlen: January 31, 1985 ARCO ANCHORAGE . Noise & Asbestos Survey G>-c A. W. Cordeira \jj D. F. Davis ^ A noise, asbestos and an environmental compliance survey was conducted on the ARCO ANCHORAGE from January 13, 1985 to January 18, 1985. The equipment used for the noise survey were: Metrosonic dB-306 and the Metrosonic dB-301. The Gilian HFS 113 Sampling Pump was used for the asbestos monitoring. The Noise survey indicated the following decibel (dB(A>) average readings. Accommodation, Deck and Service Areas Upper Engine Room Control Level Lower Engine Room 65.39 dB(A) 101.7 90.0 95.4 Noise analysis - ARCO ANCHORAGE Noise level measurements were recorded using a Metrosonic dB-306 throughout the vessel, including occupied and non-occupied accommodation spaces, machine spaces and service spaces. Crew members were requested to wear Metrosonic dB-301, Metrologgers to evaluate the 24-hour effective exposure level (LEFF (24)). The dosimeters recorded integrated noise levels between 70-134 dB for up to a 24-hour time period. The dosimeters were calibrated before each sample session, using a Metrosonic calibrator. -' The dosimeter used produced noise exposure data as an average sound level measurement evry three minutes, with hourly averages and cummulative summary. January 31, 1985 D. F. Davis Page 2 * <. Asbestos samples were taken with the Cillan HFS-113 Sampling pump, calibrated to 2 liters per minute. Eight hour samples were taken. The samples were then anlayzed by IT Corporation Analytical Laboratory. Ten samples were taken from various areas (see attachment Unprotected persons should not be exposed to airborne asbestos fiber concentrations in excess of 2.0 fibers per cubic centimeter of air averaged over an S-hour work day. Persons should not be exposed to airborne asbestos fiber concentrations in excess of 0.1 fibers per cubic centimeter of air in a living environment. The ARCO ANCHORAGE concentration levels of asbestos are well in compliance outlined in the I'SCG NAVIC 5-80. IT ANALYTICAL SERVICES 17605 Fabrica Way Cerritos. California 90701 213-921-9831 / 714-523-9200 CERTIFICATE OF ANALYSIS Prepared For: Arco Marine 300 Ocean Gate Long Beach, CA 90804 Attn: Danny Davis Date: December 6, 1984 Date Received: DeCember 4 1984 P O. Number: Verbal Job Number: 31487/rjc Nine (9) filter cassettes. The filters were analyzed for airborne asbestos by phase-contrast light microscopy using NIOSH Method P & CAM 239 . No sample blank was included. The results are as follows. Sample #1 #2 #3 #4 #5 #6 #7 #9 #10 Fibers/Fields 1/100 0.5/100 2.5/100 1.5/100 2/100 1.5/100 0.5/100 5.5/100 0.5/100 Volume (L) 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 Fibers/cm3 0.003 0.001 0.007 0.004 0.006 0.004 0.001 0.02 0.001 I certify that this report truly represents the finding of work performed by me or under my direct supervision. Reviewed and Approved. Mart I MarjrHammons Chemist Accredited by the Amencan Industrial Hygiene Association CORPORATION IT ANALYTICAL SERVICES 17605 Fabrics Way Cerritos. California 90701 213-921-9831 / 714-523-9200 CERTIFICATE OF ANALYSIS Prepared For: Arco Marine 300 Ocean Gate Long Beach, CA 90804 Attn: Danny Davis Date: December 6, 1984 > - Date Received: Decen,ber 4, 1984 P0 Number: Verbal Job Number: 31487/rjc Nine (9) filter cassettes. The filters were analyzed for airborne asbestos by phase-contrast light microscopy using NIOSH Method P & CAM 239 . No sample blank was included. The results are as follows. Sample #1 #2 #3 *4 #5 #6 #7 #9 #10 Fibers/Fields 1/100 0.5/100 2.5/100 1.5/100 2/100 1.5/100 0.5/100 5.5/100 0.5/100 Volume (L) 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 a Fibers/cm 0.003 0.001 0.007 0.004 0.006 0.004 0.001 0.02 0.001 I certify mat this report truly represents the finding of work performed by me or under my direct supervision. Reviewed and Approved. tin o^J Marjrrfammons Chenurst Accredited by the Amencan Industnal Hygiene Association IT ANALYTICAL SERVICES 17605 Fabrica Way Cerritos, California 90701 213-921-9831 / 714-523-9200 CERTIFICATE OF ANALYSIS Prepared For: Arco Marine 300 Ocean Gate Long Beach, CA 90804 Attn: Danny Davis Date: Date Received: December 4, 1984 P0. Number: Verbal December 6, 1984 - ' " -x . i* Job Number: 31487/rjc Nine (9) filter cassettes. The filters were analyzed for airborne asbestos by phase-contrast . light microscopy using NIOSH Method P & CAM 239 . No sample blank was included. The results are as follows. Sample Poorvi ^ #1 Op #2 Gf* C O^vtto t ^TR7iOM#3 Cfe 0,Ou.t->4, #4 Spcp- #5 l uPKt CrOot flootA E&- *7 Tipi-c j r;ftv ft *9 ^ 2 >40^ tv'JC-L #10 r* T Er*\9 . I T-iSM Fibers/Fie Ids 1/100 0.5/100 2.5/100 1.5/100 2/100 1.5/100 0.5/100 5.5/100 0.5/100 Volume (L) 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 3 Fibers/cm 0.003 0.001 0.007 0.004 0.006 0.004 0.001 0.02 0.001 1 certify that this report truly represents the finding of work performed by me or under my direct supervision. Reviewed and Approved. tlflapkJ f^c>Yy\yyr\.{n^d Mar4 gammons ChemT . **t.a teltanager Technical Service Accredited by the American Industrial Hygiene Association 3 CORPORATION IT ANALYTICAL SERVICES 17605 Fabrica Way Cerritos. California 90701 213-921-9831 / 714-523-9200 CERTIFICATE OF ANALYSIS Prepared For: Arco Marine 300 Ocean Gate Long Beach, CA 90804 . Attn: Danny Davis Date: Date Received: DeCember 4, 1984 P0' Number: Verbal December 6, 1984 - ,4... > l' Job Number: 31487/rjc Nine (9) filter cassettes. The filters were analyzed for airborne asbestos by phase-contrast light microscopy using NIOSH Method P & CAM 239. No sample blank was ' included. The results are as follows. Sample Fibers/Fields 1/100 #2 CW Sthl P^o. 5/100 #3 11= #4 W o.V.- (foov-, /#5 * #6 2.5/100 5/100 5/100 2/100 i 5/100 ^ $7 0*5/100 #9 CJl`|Ara 5.5/100 SVof LfJ* 1 #10 0.5/100 Volume (L) 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 3 Fibers/cm 0.003 0.001 0.007 0.004 0.006 0.004 0.001 0.02 0.001 I certify that this report truly represents the finding of work performed by me or under my direct supervision. Reviewed and Approved. m, AJascskt. PL- a'Kb.i M,, _anager Technical Service Accredited by the Amencan Industrial Hygiene Association CORFORATION IT ANALYTICAL SERVICES 17605 Fabrics Way Cerritos. California 90701 213-921-9831 / 714-523-9200 CERTIFICATE OF ANALYSIS Prepared For: Arco Marine Inc. . 300 Ocean Gate Long Beach, CA 90804 Attn: Bill Cordeiro Date: June 20,1984 Date Received: June 13,1984 P O. Number: Verbal Job Number: 29879/kb Two (2) bulk insulation samples. The samples were analyzed for asbestos by polarized light microscopy with dispersion staining using the EPA procedure for bulk insulations. The results are as follows. Sample Asbestos Found Percent by Area Material under bunks Beneath stwd. bunk Chrysotile None I certify that this report truly represents the finding of work performed by me or under my direct supervision. Reviewed acid Approved. Jack P. Kiehl Technical Service Staff Chemist Accredited by the American Industrial Hygiene Association CORPORATION IT ANALYTICAL SERVICES 17605 Fabrica Way Cerritos, California 90701 213-921-9831 / 714-523-9200 CERTIFICATE OF ANALYSIS Prepared For: Arco Marine, Inc. 300 Oceangate LAC 1014 Long Beach, CA 90802-4341 Attn: Bill Cordeiro Date: June 7, "RECEIVED JUN 1&1984 A. W. CORDEIRO Date Received: June g ( 1984 ' P0Number:VERBAL/Bill CordeiribNumber 29803/sls Three (3) insulation samples in plastic bags The samples were analyzed for asbestos by polarized light microscopy with dispersion staining using the EPA procedure for bulk insulations. The results are as follows. Sample Asbestos Found Material under bunks Chrysotile Subfloor stateroom #7 None Subfloor from deck of stateroom #6 & #7 None 1 certify that this report truly represents the finding of work performed by me or under my direct supervision. Reviewed and Approved. Marj\Hammons Chemr^Q Jack P. Kilhl . Tech. Service Staff Chemist Accredited by the American Industrial Hygiene Association