D. F. Davis ^
A noise, asbestos and an environmental compliance survey was conducted on the ARCO ANCHORAGE from January 13, 1985 to January 18, 1985.
The equipment used for the noise survey were: Metrosonic dB-306 and the Metrosonic dB-301. The Gilian HFS 113 Sampling Pump was used for the asbestos monitoring.
The Noise survey indicated the following decibel (dB(A>) average readings.
Accommodation, Deck and Service Areas Upper Engine Room Control Level Lower Engine Room
65.39 dB(A) 101.7
90.0 95.4
Noise analysis - ARCO ANCHORAGE
Noise level measurements were recorded using a Metrosonic dB-306 throughout the vessel, including occupied and non-occupied accommodation spaces, machine spaces and service spaces.
Crew members were requested to wear Metrosonic dB-301, Metrologgers to evaluate the 24-hour effective exposure level (LEFF (24)).
The dosimeters recorded integrated noise levels between
70-134 dB for up to a 24-hour time period. The dosimeters
were calibrated before each sample session, using a
Metrosonic calibrator.
-'
The dosimeter used produced noise exposure data as an average sound level measurement evry three minutes, with hourly averages and cummulative summary.
January 31, 1985 D. F. Davis Page 2
* <.
Asbestos samples were taken with the Cillan HFS-113 Sampling pump, calibrated to 2 liters per minute. Eight hour samples were taken. The samples were then anlayzed by IT Corporation Analytical Laboratory. Ten samples were taken from various areas (see attachment Unprotected persons should not be exposed to airborne asbestos fiber concentrations in excess of 2.0 fibers per cubic centimeter of air averaged over an S-hour work day. Persons should not be exposed to airborne asbestos fiber concentrations in excess of 0.1 fibers per cubic centimeter of air in a living environment.
The ARCO ANCHORAGE concentration levels of asbestos are well in compliance outlined in the I'SCG NAVIC 5-80.
IT ANALYTICAL SERVICES
17605 Fabrica Way Cerritos. California 90701 213-921-9831 / 714-523-9200
CERTIFICATE OF ANALYSIS
Prepared For: Arco Marine
300 Ocean Gate Long Beach, CA
90804
Attn: Danny Davis
Date: December 6, 1984
Date Received: DeCember 4 1984
P O. Number: Verbal
Job Number: 31487/rjc
Nine (9) filter cassettes.
The filters were analyzed for airborne asbestos by phase-contrast light microscopy using NIOSH Method P & CAM 239 . No sample blank was included. The results are as follows.
Sample #1 #2 #3 #4 #5 #6 #7 #9 #10
Fibers/Fields 1/100
0.5/100 2.5/100 1.5/100
2/100 1.5/100 0.5/100 5.5/100 0.5/100
Volume (L) 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0
Fibers/cm3 0.003 0.001 0.007 0.004 0.006 0.004 0.001 0.02 0.001
I certify that this report truly represents the finding of work performed by me or under my direct supervision.
Reviewed and Approved.
Mart I
MarjrHammons Chemist
Accredited by the Amencan Industrial Hygiene Association
CORPORATION
IT ANALYTICAL SERVICES
17605 Fabrics Way Cerritos. California 90701 213-921-9831 / 714-523-9200
CERTIFICATE OF ANALYSIS
Prepared For: Arco Marine 300 Ocean Gate
Long Beach, CA
90804
Attn: Danny Davis
Date:
December 6, 1984
> -
Date Received: Decen,ber 4, 1984
P0 Number: Verbal
Job Number: 31487/rjc
Nine (9) filter cassettes.
The filters were analyzed for airborne asbestos by phase-contrast light microscopy using NIOSH Method P & CAM 239 . No sample blank was included. The results are as follows.
Sample #1 #2 #3 *4 #5 #6 #7 #9 #10
Fibers/Fields 1/100
0.5/100 2.5/100 1.5/100
2/100 1.5/100 0.5/100 5.5/100 0.5/100
Volume (L) 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0
a
Fibers/cm 0.003 0.001 0.007 0.004 0.006 0.004 0.001 0.02 0.001
I certify mat this report truly represents the finding of work performed by me or under my direct supervision.
Reviewed and Approved.
tin o^J
Marjrrfammons Chenurst
Accredited by the Amencan Industnal Hygiene Association
IT ANALYTICAL SERVICES
17605 Fabrica Way Cerritos, California 90701 213-921-9831 / 714-523-9200
CERTIFICATE OF ANALYSIS
Prepared For: Arco Marine 300 Ocean Gate
Long Beach, CA
90804
Attn: Danny Davis
Date:
Date Received: December 4, 1984
P0. Number: Verbal
December 6, 1984
- ' " -x . i* Job Number: 31487/rjc
Nine (9) filter cassettes.
The filters were analyzed for airborne asbestos by phase-contrast .
light microscopy using NIOSH Method P & CAM 239 . No sample blank was included. The results are as follows.
Sample
Poorvi ^ #1 Op
#2 Gf*
C O^vtto t ^TR7iOM#3 Cfe
0,Ou.t->4, #4 Spcp-
#5
l
uPKt CrOot
flootA
E&-
*7
Tipi-c j r;ftv ft *9 ^ 2 >40^ tv'JC-L #10 r*
T Er*\9 . I T-iSM
Fibers/Fie Ids 1/100
0.5/100 2.5/100 1.5/100
2/100 1.5/100 0.5/100 5.5/100 0.5/100
Volume (L) 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0
3
Fibers/cm 0.003 0.001 0.007 0.004 0.006 0.004 0.001 0.02 0.001
1 certify that this report truly represents the finding of work performed by me or under my direct supervision.
Reviewed and Approved.
tlflapkJ f^c>Yy\yyr\.{n^d
Mar4 gammons ChemT
. **t.a teltanager Technical Service
Accredited by the American Industrial Hygiene Association
3
CORPORATION
IT ANALYTICAL SERVICES
17605 Fabrica Way Cerritos. California 90701 213-921-9831 / 714-523-9200
CERTIFICATE OF ANALYSIS
Prepared For: Arco Marine 300 Ocean Gate Long Beach, CA
90804
. Attn: Danny Davis
Date:
Date Received: DeCember 4, 1984
P0' Number: Verbal
December 6, 1984
- ,4...
> l'
Job Number: 31487/rjc
Nine (9) filter cassettes.
The filters were analyzed for airborne asbestos by phase-contrast
light microscopy using NIOSH Method P & CAM 239. No sample blank was ' included. The results are as follows.
Sample
Fibers/Fields
1/100
#2 CW Sthl P^o. 5/100
#3
11= #4 W
o.V.- (foov-, /#5
* #6
2.5/100
5/100 5/100
2/100
i 5/100
^ $7
0*5/100
#9 CJl`|Ara 5.5/100
SVof LfJ* 1 #10
0.5/100
Volume (L) 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0 960.0
3
Fibers/cm 0.003
0.001
0.007 0.004 0.006 0.004
0.001 0.02 0.001
I certify that this report truly represents the finding of work performed by me or under my direct supervision.
Reviewed and Approved.
m,
AJascskt. PL- a'Kb.i M,, _anager Technical Service
Accredited by the Amencan Industrial Hygiene Association
CORFORATION
IT ANALYTICAL SERVICES
17605 Fabrics Way Cerritos. California 90701 213-921-9831 / 714-523-9200
CERTIFICATE OF ANALYSIS
Prepared For: Arco Marine Inc.
.
300 Ocean Gate
Long Beach, CA 90804
Attn: Bill Cordeiro
Date: June 20,1984
Date Received:
June 13,1984
P O. Number:
Verbal
Job Number:
29879/kb
Two (2) bulk insulation samples.
The samples were analyzed for asbestos by polarized light microscopy
with dispersion staining using the EPA procedure for bulk insulations. The results are as follows.
Sample
Asbestos Found
Percent by Area
Material under bunks Beneath stwd. bunk
Chrysotile None
I certify that this report truly represents the finding of work performed by me or under my direct supervision.
Reviewed acid Approved.
Jack P. Kiehl Technical Service Staff Chemist
Accredited by the American Industrial Hygiene Association
CORPORATION
IT ANALYTICAL SERVICES
17605 Fabrica Way Cerritos, California 90701 213-921-9831 / 714-523-9200
CERTIFICATE OF ANALYSIS
Prepared For: Arco Marine, Inc. 300 Oceangate LAC 1014 Long Beach, CA 90802-4341
Attn: Bill Cordeiro
Date: June 7,
"RECEIVED
JUN 1&1984 A. W. CORDEIRO
Date Received: June g ( 1984
' P0Number:VERBAL/Bill CordeiribNumber 29803/sls
Three (3) insulation samples in plastic bags
The samples were analyzed for asbestos by polarized light microscopy with dispersion staining using the EPA procedure for bulk insulations. The results are as follows.
Sample
Asbestos Found
Material under bunks
Chrysotile
Subfloor stateroom #7
None
Subfloor from deck of stateroom #6 & #7
None
1 certify that this report truly represents the finding of work performed by me or under my direct supervision.
Reviewed and Approved.
Marj\Hammons Chemr^Q
Jack P. Kilhl . Tech. Service Staff Chemist