Document rp4Jy65OkeJNGO72KGJ2RjBaE
General Offices/3M 3M Center St. Paul, Minnesota 55101 612/7331110
March 19, 1979
TO HOLDERS OF THE 3M OCCUPATIONAL HEALTH AND SAFETY PRODUCTS INFORMATION BINDERS: Please find enclosed a copy of our new literature on the 3M Brand Organic Vapor Monitor and Analytical Service. Please place this literature in your black and green 3M OH&SP Product Information Binder under the section marked Personal Monitoring Services. We thank you for your interest in 3M safety products and will keep you updated on all new introductions of products or product changes as they occur. If you desire more information on any of our occupational safety products, please feel free to contact your local 3M safety products distributor or call our toll free number 1-800-328-1300 and ask for Customer Service. Thank you.
Carole Sustak Marketing Communications Supervisor 3M Occupational Health & Safety Products Division
3M 105780
3M
In response to you and your workers
The first maintenance-free
3M 105781
3M Brand
ORGANIC V\POR MONITOR
3500
Makes monitoring easier for everyone involved from planning through purchase through analysis
3M Brand Organic Vapor Monitor 3500 is maintenance-free. An economic and time-saving benefit for those who must allocate budget to buy the monitor as well as for those who must administer the program.
For wearers, it's lightweight, self-contained and comfortably worn on the collar to measure TW.A. concentrations over a period of 8 hours or less. Compact, lightweight design helps assure worker acceptance.
Ready-to-use
No equipment preparation or calibration. Saves time, labor and money.
No spare parts inventory to tie up capital and space.
Maintenance-free, single use unit. No cleaning or worry about contamination hold-over.
Low initial cost.
Exceeds OSHA accuracy requirements.
Will measure recommended compounds at their action levels or below
Lightweight, pumpless
Self-contained. No expensive pumps. No interference with normal work procedure.
Conveniently clips to collar close to breathing zone. Provides precise measurement of personal exposure.
Vapors sampled at constant rates.
Simplified monitoring procedure. Hygienist can work through trained aides in remote locations.
Lower hygienist cost per sample. In cases of an on-location hygienist, a greater number of samples can be taken in a given period
Internal desorption
Sample is sealed within mot to prevent unintentional contamination after the monitoring period.
Desorption occurs in the clc monitor. Eliminates potential inaccuracies due to sorbent transfer.
Eliminates time in handling ; analysis preparation.
3M 105782
"tally, for laboratory personnel, there's the ease id accuracy of analysis, (Desorption is ;rformed inside the monitor.) 3M provides tmplete calculation data to your laboratory, 3M so offers a specialized analysis for the monitor.
>00 offers a unique combination of benefits, and 3re's at least one benefit for everyone involved in 3 overall monitoring cycle from purchase through alysis.
Conventional analysis
Uses conventional gas chromatographic analysis as outlined in NIOSH Physical & Chemical Analytical Method 127.
To speed and assure analysis consistency, 3M offers an Analytical Service or can provide complete standardized calculation data, including sampling rate and recovery coefficient. To obtain this information for your laboratory, complete and send the request card contained in every monitor shipping box.
Civ**'*''4-*"'
''7;v
A;'
C-A
Low flow pump and carbon tubes
Purchases Necessary 1. Pump 2. Battery Charger 3. Pumpcase 4. Tubes 5. Tube Holder 6. Bubble Flow Calibrator 7. Stopwatch 8. Replacement Parts
Preparation For Monitoring 1. Charge pump 2. Calibrate pump & set flow rate
Monitoring Procedure 1. Affix to wearer. 2. File & break tube ends. 3. Mount tube in holder. 4. Turn pump on. 5. Record start time, data & pump index #. 6. Record sampling conditions. 7. Remove & turn pump off. 8. Record end time, data & index #. 9. Make label & identify tube.
10. Cap ends. 11. Package for shipment.
Preparation For Analysis 1. Label 2 vials. 2. File & break tubes. 3. Remove wadding. 4. Transfer back up carbon to vial #1. 5. Remove wadding. 6. Transfer main carbon to vial #2.
Analysis and Calculation 1. Inject solvent to vials 1 & 2. 2. Analyze vials 1 & 2. 3. Compute volume of air sampled. 4. Compute weight of compound. 5. Compute ppm over period of exposure.
i'
Package closure /
/
i
v
V
V FoiMlned package
Monitoring
1, Start time is recorded on the back of the monitor.
2. The monitor is worn as close as possible to the breathing zone to provide ine best possible monitoring of personal exposure.
3. After exposure, the end time is recorded.
\
\
Pour spout | Closure cap { '
Analysis
The sealed, foil-lined package can be sent to 3M for monitor analysis (see back cover for details), or be
forwarded for analysis by your own laboratory or local analytical service. If you prefer to use
sources other than 3M, complete
qualification and calculation data can be provided for a variety of compounds including but not limited to:
Acetone
Hexane
Acrylonitrile
Benzene (AssoMion Oil ppm)
Carbon Tetrachloride
Methyl Ethyl Ketone
Styrene
Toluene
Chloroform Trichloroethylene
Ethyl Acetate Vinyl Chloride
Heptane
Xylene
4. The white face and retaining ring
are removed after monitoring.
1. As the first step in analysis, the
eluent is injected through the center port.
5. The closure cap is snapped into place and the ports are firmly closed.
6. Specific data and comments are written on the package.
7. The monitor is placed inside the package which is folded and sealed with the closure tube.
2. The port is closed. The sample Is desorbed for 'h hour with occasional gentle agitation.
3. Both ports are opened and the pour spout can be inserted. The solution is poured into the sampler vial.
4. Sample analysis is by conventional gas chromatography and use of the 3M qualification data.
3M 105785
AIHA ACCREDITED
Backed by the expertise of 3M --
MONITOR ANALYTICAL SERVICE
The easy, accurate system
The same expertly staffed and fully equipped laboratory which developed the 3500 Organic Vapor Monitor can also provide complete gas chromatographic analysis.
The complete 3M package is offered for your convenience. It provides an economical and efficient means to get results quickly and accurately.
The corrugated shipping box in which the monitors are initially packaged is also a ready-to-use return mailing carton to 3M. Monitors are packaged ten to a box.
72-Hour Lab Turnaround Time
At 3M, samples will be carefully analyzed and you can be confident of the results. A written confidential report on each monitor will be quickly returned to you. 3M offers 72-hour lab turnaround time. The reports will also be kept on file for your future reference.
IMPORTANT NOTICE TO PURCHASER
THE FOLLOWING WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PURPOSE, 3M OH & SP products sold will meet the physical standards and properties set forth in the applicable product specification data sheets issued by 3M. 3M's only obligation under this warranty shall be to replace such quantity of 3M OH & SP products proved to be defectively manufactured by failing to meet the aforementioned specification data sheets, and to be responsible for any third party personal injuries directly caused by said defects Except as provided above, 3M shall not be liable or responsible for any loss, damage, or liability, direct, indirect, incidental, special or consequential, arising out of the sale, use or misuse of, or the inability to use products by the user.
ANOTHER STEP TOWARDS BETTER OCCUPATIONAL HEALTH AND SAFETY
R-OVMB ( 3(J4 ) MP
Occupational Health and Safety Products Division/3M 220-7W 3M Center St. Paul, MN 55101
Lulm m U S A with 3M BRAND Photo Offset Pf.itcs, Film and Ctumucals
3M 105786