Document rp3R3gBXa3vGJ8p18JYzM77oG
DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service ^ J/
Centers for Disease Control
National Institute for Occupational
October 15, 1984
Safety and Health -- ALOSH 944 Chestnut Ridge Road
SPECIAL REPORT TO RESPIRATOR USERS
Morgantown, WV 26505--2888
ON NIOSH RESPIRATOR PROBLEM INVESTIGATION
Between July 1, 1982, and August 1, 1984, the National Institute for Occupational Safety and Health (NIOSH) investigated 72 reports of problems involving defects or difficulties with Mine Safety and Health Administration (MSHA)/NIOSH-approved respirators. These reports were received from the following sources:
Source of Report
Number of Reports
NIOSH audit
26
Fire service
21
Other government agencies
13
Industrial
9
Labor union
2
Respirator manufacturer
1
PLAINTIFF'S EXHIBIT
Upon receipt of each report, NIOSH categorized it according to the following severity classification system:
A. Report of a defect or difficulty which has caused or may cause immediate death, injury, or illness to the respirator user, such as sudden loss of breathing gas from a self-contained breathing apparatus before or during use;
B. Report of a defect or difficulty which may cause future illness to the respirator user, such as lowered protection from a dust, fume, and mist respirator;
C. Report of a defect or difficulty which will probably result in rejection of or refusal to use a respirator, such as high breathing resistance; and
D. Report of a defect or difficulty which has no immediate or future relationship to the health and safety of the respirator user, such as an unapproved change that does n>t affect the performance of the respirator.
The 72 reports, received between July 1, 1982, and August 1, 1984, were classified for severity as follows:
Severity Classification
A B C 0
Number of Reports 25 6 33
7
UM070527
Between July 1, 1982, and August 1, 1984, NIOSH issued 3 Respirator User Warnings and 10 Respirator User Notices, using a list of approximately 8500 Industrial Health and Safety organizations and personnel. NIOSH has been studying the effectiveness of this procedure for informing respirator users of the existence of problems involving defects or difficulties with MSHA/NIOSH-approved respirators.
SC 009315
Page 2
It appears that with the valuable assistance of dedicated fire service personnel and organizations, NIOSH warnings and notices relating to fire fighting respirators rapidly reach a high percentage of persons who need that information. However, NIOSH warnings and notices relating to industrial respirators may be less effective. NIOSH will investigate ways to improve this situation during the forthcoming year.
After investigating a report of a problem, NIOSH is able to more completely define it. The reports received between July 1, 1982, and August 1, 1984, are defined as follows:
Defect or Difficulty_____________________________
Immediately dangerous to life or health
Mechanical defect
Sudden loss of breathing gas
Temperature extreme
Respirator leakage
Not immediately dangerous to life or health
Mechanical defect
Service life
Sorbent/filter dusting . .
..
Respirator leakage
Resistance
Chemical effects.
Gradual loss of breathing gas
Packaging -
Unapproved assembly \ _
Facepiece irritation
Temperature extreme .
.
Number of Reports
15 8 2 .. 1
.w.
17 7
. . : 5, . 4 3 2 2 2 2 1
1
.-
......................................... ...........................................e
r ~
NIOSH is continuing its program of working with respirator manufacturers
and respirator users in investigation of reports of problems with
MSHA/NIOSH-approved respirators. As indicated in the Guidelines for.
Reporting Respirator Problems, issued July 21, 1983, NIOSH encourages
users who find problems with MSHA/NIOSH-approved respirators to report
them directly to the respirator manufacturer, with a copy of the report
to NIOSH. NIOSH will only take an active part in resolution of the
defect or difficulty if the user and manufacturer are not successful, the
situation is immediately dangerous to life or health, or it is one which
may appear in other respirators currently in use.
The procedure of direct communication between the reporter and the manufacturer appears to be working satisfactorily. However, some reporters indicate difficulty in reaching a person at the manufacturer's facility with the authority and/or interest in resolving the problem. To assist future reporters, NIOSH has prepared the attached list of representatives of respirator manufacturers, who have been authorized to handle such reports in a timely manner.
Attachment
y^^John B. Moran
so LAM010528
NAMES AND ADDRESSES OF PERSONS WHO ARE RESPONSIBLE FOR INVESTIGATION PROBLEMS WITH MSHA/NIOSH-APPROVED RESPIRATORS
Respirator Manufacturers
Mr. William Washburn AGA Corporation 550 County Avenue Secaucus, NJ 07094
Mr. S. B. Shearer CSE Corporation 600 Seco Road Monroeville, PA 15146
Mr. Mark Theno Air-Tek Company 6472 Flying Cloud Drive Eden Prairie, MN 55344
Mr. Carl M. Fink Defense Apparel 285 Murphy Road Hartford, CT 06114
Mr. Joseph Zdrok American Optical^Corp. 14 Mechanic Street Southbridge, MA 01550
Mr. Ronald J.DeMeo Clifton Precision . . , P.0. Box 303 Frederick, Delaware 19946 <-
Mr. Raymond 0. Day Mr. Robert Meyer Binks Manufacturing Co. 9201 W. Belmont Ave. Franklin Park, IL 60131.
Dr. Helmut Sieber Draegerwerk AG Lubeck ^ Postfach 1339 2400 Lubeck 1 Federal Republic of Germany
Mr. Willie Yung
Louis M. Gerson Company
15 Sproat Street
....
Middleboro, MA 02346
Mr. Joel Kaufman Glendale Opeical Co. 130 Crossways Park Drive Woodbury, NY 11797
Mr. Steve Boro E. D. Bullard Company 2680 Bridgeway Sausalito, CA 94965
Mr. Stephen H. Bates Globe Safety Equipment, Inc. PO Box 7248 Dayton, OH 45407
Mr. John B. McCreadie Cesco Safety Prod./Parmalee Ind. U. S. Safety Service Co. P.0. Box 1237 Kansas City, MO 64141.
Ing. G. Cappa Industrie Pirelli SPA Azienda Articoli Vari Roma Via di Torresoaccata 140-0016 Roma, Italy
Mr. Martin Ziegler Clifton Precision Division of Litton Ind. P. 0. Box 303, Rt. 113 Frederica, DE 19946
Mr. W. F. Moon Cover, H.S. Co. 107 East Alexander St. Buchanan, MI 49107.
Mr. Donald M. Dawson International Safety Instruments, PO Box 846 Lawrenceville, GA 30246
Inc.
Mr. Bengt Sjard
Interspiro AB S-181 81 LIDINGO Sweden
SC 009317 LAM010529
Mr. Ron Therrin Lane8 Industries 12704 N. E. 124th Street Kirkland, Washington 98033-4091
Mr. Earl B. Jacobson ' Nuclear Power Outfitters PO Box 84 Crystal Lake, IL 60014
Mr. Carlos E. Lean Masprot, No. 5558 San Miguel Santiago, Chile
Mr. Pat Droppleman Ocenco, Incorporated 400 Academy Drive Northbrook, IL 60062
Mr. T. D. McConnell Mine Safety Appliances Company 600 Penn Center Boulevard Pittsburgh, Pennsylvania 15235
Mr. Donald P. Wilines 3M Company 3M Center Building 230-B-06 St. Paul, MN 55144
F. Levi-Senlgaglia Pirelli Industrial Products. 6 Ram Ridge Road ' Spring Valley, NY 10977
, Mr. George Lamoy
. r riv-col .iH
Portable
Air
Supply
Systems
C__o__rIp
1 *.
c
O
i.-j ; -j
' l' J 3500 Carnegie Avenue Cleveland, OH 44115
**" dr!?
Mr. Albert Mints
Moldex/Metries, Incorporated
4671 Leahy Street
^'
Culver City, California 90230 9: " ' ... --V. K'
Mr. Les Boord
. J , Mr. M. D. Shroff
09MsC*1
Ji Pradeep Raja Bahadur Motilai Mansion
1st Floor 11/43 Tamarind Street
x jS
Fort Bombay - 400023, INDIA ^
-f x i i
Mr. Jay Parker
... .rr
!Z
^ _ s(>
Mr. Wes Kenneweg
. I.
National Draeger, Inc.
P. 0. Box 120
''V T \
Pittsburgh, Pennsylvania 15230
, Pulmosan Safety Equipment Corp. '
e 30-48 Linden Place '' Flushing, NY 11354
* ' i --
_ .;
: :Dr
' 7
M
* i. - c
, r*;. .... . ..
. f ... i .ii , xr1 > ;i I :*!
Mr. Stephen C. Smith
Mr. Donald Burd 9 Racal Airstream, Inc.
'.-,0
-.it
National Mine Service Company
7309A Grove Road
600 N. Bell Ave., Bldg. 2, Ste 110 . Frederick, MD 21701
Carnegie, Pennsylvania 15106
Mr. Ben Huey
Mr. Ken Vaughn
Rexnord Safety Products
Neoterik Health Tech., Inc.
45 Great Valley Parkway
P.0. Box 78
Malvern, PA 19355
Mt. Airy, MD 21771
Mr. Walter Anderson
Ms. C. E. Chappron
Robertshaw Controls Co.
North Safety Equipment
333 North Euclid Way
2000 Plainfield Pike
Anaheim, CA 92803
Cranston, RI 02920
Mr. Gerald S. Gilbert
Romiro Technology
3500 Carnegie Avenue
Cleveland, OH 44115
& LAM010530
Mr. Ian V. Maxwell Sabre Safety, Ltd. Ash Road, Aldershot Hampshire, GU12 4DD England
Ms Antonette Bonfiglio (Air-purifying respirators) U.S.D. Corp. 3323 Uest Harner Ave. Santa Ana, CA 92702
Mr. Ross Kusian Safety and Supply Co. 5510 East Marginal Hay South Seattle, HA 98134
Mr. Robert Brennan Scott Aviation 225 Erie Street Lancaster, N.Y. 14086
Mr. Simon Kugler Siebe Gorman, Ltd. Avondale Hay, Cwmbran, Gwent, Hales NP4 1 YR, Great Britain
Mr. Brian Miller (Atmosphere-supplying respirators) U.S.D. Corp. 3323 Hest Harner Ave. Santa Ana, CA 92702
Mr. Robert Bischler Hillson Safety Products PO Box 622 Reading, PA 19603
Mr. Larry Schaefer Standard Safety Equipment Corp. P.0. Box 188 Palatine, IL 60067
Mine Safety and Health Administration
Mr. Kenneth P. Klouse MSHA Approval and Certification Center PO Box 251, Route 1 Triadelphia, WV 26059
National Institute for Occupational Safety and Health
Respirator Problem Coordinator Division of Safety Research NIOSH,CDC,PHS,HHS 944 Chestnut Ridge Road Morgantown, HV 26505
SC 009319
UM070531