D. E. Roush - St. Louis February 25, 1971 Change from Thermlnol FR to Thermlnol 66 Heat Transfer Fluid MIKE PIERIE TECHNICAL SERVICE KPT. KLAWARE RIVER PLANT J. J. Roder - jrobb B. Papageorge - WPAPA J. R. Fallon - JPALL Pursuant to our telephone conversation of February 23 regard ing the possible change from Thermlnol FR (Aroclor) fluids in the phthallc and tetrathal units at Delaware River to Therml nol 66, I have attached the following: Thermlnol Heat Transfer Coefficient and Pressure Drop Data Book Thermlnol 66 Data Sheet Thermlnol FR Disposal Bulletin We are very much Interested in eliminating Thermlnol FR (Aro clor) leakage from Monsanto's heat transfer systems. In this regard, we would hope to contain and control any leakage from a Thermlnol FR containing system. If leakage cannot be ade quately controlled, then we would strongly recommend a change to a more ecologically accepted fluid such as Thermlnol 66 or Thermlnol 55 In the case of the phthalllc and tetrathal heating systems at Delaware River I strongly urge a change to Thermlnol 66, not only to overcome a potential pollution problem, but to obtain longer term performance from the heat transfer liquid. Ther mlnol 66 has a top use temperature of 650*F, whereas Thermlnol PR-1 and PR-2 products have a top use temperature of 600*F. This extra 50* can be a real benefit In terms of operating costs for these two heating systems. I do not feel any change of equipment will be required In the phthallc unit to use Thermlnol 66 from the Thermlnol PR-1 pro duct (Aroclor 1242). The still tank, reboller, and heater treaters will accept Thermlnol 66 without any modification. I would suggest you eliminate the Inert gas sparge on the expan sion tank system and replace It with an Inert gas pad. The vent line can be terminated in a back pressure relief valve to maintain one or two pounds pressure on the expansion tank system. It will also be necessary to provide a safety relief device for liquid in addition to the back pressure controller on the expansion tank vent. Clean out of the heat transfer system Is recommended prior to filling with Thermlnol 66. A non-chlorlnated solvent-toluenewlll be satisfactory as long as the toluene residual Is com pletely removed from the system prior to filling with T-66. HONS 098276 -2- Zt will also be necessary to Install a fire protection device in the heater proper. This can be accomplished by using a steam flood nozzle with a manual oontrol valve located at a safe distance from the heater. I would assume the production unit Incorporates fire protection gear that would also be ade quate for the Thermlnol 66 which Is a flammable heat transfer fluid. I would suggest, however, that you consult with plant safety to obtain their opinion in this regard. Beoauae the tetrathal unit has recently been recharged with fresh,Aroclor, I assume a change to T-66 will be considered at a later date. Peel free to call either Jim Roder or me In St. Louis for in formation on Thermlnol fluids. os Attachments (3) V. S. Roush MONS 098^77