Document reroog6ZQzxrG4864vLyZZ2a7
AIRBORNE DUST COUNTS
for Georgia-Pacific Corporation
Marietta, Ga.`
Decenber 8, 1972
Personnel Present
H. Scharf Georgia-Pacific Corporation
E. J. Xleber Union Carbide Corporation
J. E. Walsh Union Carbide Corporation
UNION CARBIDE CORPORATION Mining and Metals Division Niagara Falls, New*York
PLAINTIFF'S EXHIBIT UC-4993
SGP 000656
Description of Plant and Tests .
Tests were conducted October 30* 1972 manufacturers pf tape joint compounds.
at Georgia-Pacific Corp., Marietta, Ga.,
Asbestos is adJfcd at a hopper which has an overhead, negative pressure hood. Personal samples were collected.from both the man dumping asbestos and his assistant, handing him the bags. A personal sample was also obtained during the dumping of mica. An environmental sample was placed near the dumping area and allowed to run for approximately one hour.
Sampling and dust counting were carried out in accordance with OSHA Regulation 1910.93a, using the Bayer, Zummalde and Brown method for counting asbestos fiber; by phase contrast microscopy (Bureau of Occupational Safety and Health, Feb. 1965
Battery powered air pumps (M.S.A. type) calibrated to liters per minute were us to collect personal breathing zone and environmental si spies on millipore membrar filters of 0.8 micron porosity.
Fiber counting was performed on a Leitz microscope utilizing phase contrast illun tion at 400X and a Patterson Globe and Circle reticle.
Total dust was determined by light field microscopy at 100X,
Test Results
Two figures have been reported for each sample. They are:
1) Total Fiber - Any material 5 microns or longer having an aspect ratio of 3 or greater. Reported as fibers per milliliter.
2) Total Dust - Any fiber or particle present. Reported as million particles per cubic foot.
Interpretation
The regulations have been established with the $ fiber limit on a time-weighted average. This essentially means the figures must be arranged to show an employee average intake of fibers per milliliter on an'8-hour day. For example, the highc. reading in the test was 8.0 fibers/ml. If this was the only contact with asbesti that day, the 2-minute sample would be extrapolated to 6 hours, giving a time-weij average of less than 0.04 fibers/ml.
SGP 000651
N.B. No. 1929-48-1
1929-48-2 1929-48-3 1929-48-4
SUWARY OF DUST COUNTS
Description
Fiber Count Fibers/nl. > 5ta,
Environmental - "Background" sample near filler bins on
(81 ain.)
ladder 15 ft. from bag hopper for saall
raw material ingredients.
1.7
Peronal (2 Kin.)
- Operator's assistant handing bags to aan who dumps.
8.2
*
Personal (2 ain.)
Personal (2 ain.)
- Operator dumping 2 bags 7RF9 and 3 bags SG-210
- Operator draping 7 bags Muscovite mica -
8.0 3.6
1
m
( 1< i:
SGP 000656
AIRBORNE OUST COUNTS
for Georgia-Pacific Corporation
Marietta, Ga.
December 8, X972
Personnel Present:
H. Scharf Georgia-Pacific Corporation
E. J. Kleber Union Carbide Corporation
J. E. Walsh Union Carbide Corporation
UNION CARBIDE CORPORATION Mining and Metals Division Niagara Falls, New.York
SOP 0006571
Description of Plant and Tests
Tests were conducted October 30, 1972 at Georgia-Pacific Corp., Marietta, Ga., manufacturers of tape joint compounds.
Asbestos is added at a hopper which has an overhead, negative pressure hood. Personal samples were collected.from both the man dumping asbestos and his assistant, handing him the bags. A personal sample was also obtained during the dumping of mica. An environmental sample was placed near the dumping area and allowed to run for approximately one hour.
Sampling and dust counting were carried out in accordance with OSHA Regulation 1910.93a, using the Bayer, Zummalde and Brown method for counting asbestos fibers by phase contrast microscopy (Bureau of Occupational Safety and Health, Feb. 1969
Battery powered air pumps (M.S.A. type) calibrated to 2 liters per minute were us to collect personal breathing zone and environmental samples on millipore membran filters of 0.8 micron jorosity.
Fiber counting was performed on a Leitz microscope utilizing phase contrast ilium tion at 400X and a Patterson Globe and Circle reticle.
Total dust was determined by light field microscopy at 100X.
Test Results
Two figures have been reported for each sample. They are:
1) Total Fiber - Any material 5 microns or longer having an aspect
ratio of 3 or greater. Reported as fibers per
. milliliter.
. ......
2) Total Dust - Any fiber or particle present. Reported as million particles per cubic foot.
Interpretation
The regulations have been established with the 5 fiber limit on a time-weighted average. This essentially means the figures must be arranged to show an employee average intake of fibers per milliliter on an'8-hour day. For example, the highe reading in the test was 8.0 fibers/ml. If this was the only contact with asbest that day, the 2-minute sample would be extrapolated to 8 hours, giving a time-wei average of less than 0.04 fibers/ml.
SGP 000657;
SUMMARY OF DUST COUNTS
N.B. No. 1929-48-1
1929-48-2
1929-48-3
1929-48-4
Description
Environmental - "Background" sample near filler bins on
(81 min.)
ladier 15 ft. from bag hopper for small
raw material ingredients.
Fiber Count Fibers/ml. >S
1.7
Personal (2 min.)
- Operator's assistant handing bags to man who dumps.
6.2
Personal (2 min.)
- Operator dumping 2 bags 7RF9 and 3 bags SG-210
8.0
Personal (2 min.)
- Operator dumping 7 bags Muscovite mica
3.6
Ti Di Ha #
4
6.
10.
13.
SGP 000657*