Document repDzLbJnRdR2235Y22mQVJJ
o
AMERicAN-^tandard
*Hydronic Heating Equipment
trade price book
'Hydronics . . . the science of heating and cooling with water.
Boilers:
PRODUCTS
Gas--Packaged Units
Boilers Only
Electronic Control Systems
Oil --Packaged Units
Boiler--Burner Units
Boilers Only
Stoker Boilers
Hand fired Boilers
Radiation:
Baseboard Panels --Radiantrim
--Heatrim
Convectors
--Multifin
-Arco
--Cabinet Extras
Radiators--Arco, Sunrad, Peerless
Oil Burners and Controls
Zone Control Sets
Gas Conversion Burners
Repair Parts Discounts
Terms
Sales Offices
General Information
PAGE
3-5 6-14
15 17 18-29 18-29 33-34 35-37
39 40-41 42-44
45 46 38-39 30-32 30 16
47 48
HH-2
JULY 5, 1961
notice: The Trade Prices shown herein do not include freight or cartage.
American-Standard
PLUMBING AND HEATING DIVISION
AMtICAN AOIATO A STANDARD SANITAtT CORPORATION
04530
GENERAL INFORMATION
AMERicAN-fStandard
H YD RON I C HE ATI NO
BOILER RATINGS
Boiler ratings ("net I=B=R ratings of Mbh and sq ft of
steam", "net rating sq ft water" and "installed radiation", where shown) represent the maximum net loads that may be connected to the boilers. Steam sq ft ratings are based on 240 Btu per sq ft and water sq ft ratings oh ISO Btu <170* water) per sq ft. Allowances have been made in these ratings for normal piping (covered) and pick-up loads and for heat ing domestic hot water under the following conditions:
It is not necessary to increase the boiler size for domestic hot water supply when not more than two bathrooms are to be served or if the use of domestic hot water does not exceed seventy-five gallons in twenty-four hours.
Sufficient radiation must be installed for the requirements of the building.
In order to select the proper size boiler calculate the heat loss of the building, then divide this figure by 1,000 to get the heat loss expressed in Mbh. Select a steam or wster boiler which has a net Mbh rating equal to or greater than this fig ure using the appropriate steam or water column.
See current literature for determining the size of radiators and convectors for hot water systems.
For an installation where unusual conditions such as large pipe losses, intermittent heating, unbalanced systems, etc., are encountered, it is suggested to calculate the actual piping loss and estimate the pick-up factor to adjust the load and then select the boiler from the published gross output in Mbh (1,000 Btu per hour).
GAS FIRED BOILERS
The input and output ratings are approved by the American Gas Association.
Ratings shown are for installations at sea level and at eleva tions up to 2,000 feet For altitudes above 2.000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
OIL FIRED BOILERS
The firing rates or I=B=R burner capacity--gallons per hourare based on the use of oil having 140,000 Btu per gallon heat value, and with 10% CO: in the flue gas.
When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity.
When Built-in Tankless Heater is used increase the boiler size 12 Mbh for each bathroom in excess of two.
STOKER FIRED BOILERS
The firing rates or I=B=R burner capacity pounds per hourare based on the use of coal having 13,000 Btu per pound heat value.
When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity.
HAND FIRED BOILERS
The ratings (installed radiation sq ft) are based on the use of stove or nut size bituminous coal, anthracite coal or coke with 13,000 Btu per pound heat value. See table below for select ing proper size boiler when using coal with less than 13,000 Btu per pound.
When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity.
BUILT-IN WATER HEATERS (for Arcoliner, Oakmont, Severn, Exbrook Boilers)
All tank type Built-in water heaters are rated on the basis of raising the temperature of the domestic hot water 100*F. in three hours with a minimum boiler water temperature of 180*F. on automatically fired boilers and 212*F. on hand fired boilers.
All tankless type Built-in water heaters are rated in gallons per minute on the basis of a minimum boiler water tempera ture of 180*F. on oil fired boilers. The maintaining of 180*F.
boiler water temperature with rated flow through a tank less type Built-in water heater is dependent on the oil firing rate for the boiler.
In those areas where excessive lime exists in the water, use of Built-in Tankless Type water heater is not recommended except when provision is made for regularly cleaning the heater. Use of Tank Type heater is recommended in hard water areas.
WHEN PIPING LOSS IS NEGLIGIBLE
The ratings (installed radiation) of steam boilers (all fuels) and coal (hand fired) water boilers may be increased by the percentages shown below when the piping loss of the installa tion is negligible. The ratings (installed radiation) of auto matically fired water boilers may be increased by 12% when the piping loss of the installation is negligible.
ratings Installed radiation sq ft
Staam (all fuais)
Watar coal (hand flrad)
Incraasa ratings
by
up to 250 251- 500
501-1000 1001-1500 1501-2000 2001-3000 3001-4000
over 4000
up to 400
401- 800 801-1600 1601-2400 2401-3200 3201-4800 4801-6400 over 6400
30% 28% 24%
21% 18%
15% 13% 12%
WHERE COAL HAS LESS THAN 13,000 BTU CONTENT
When selecting hand fired boilers for burning coal of lower heating value than 13,000 Btu per pound the following correc tion factors should be used. Multiply the net load by the proper factor and select the boiler with the corresponding rating (installed radiation sq ft).
hitting valua of coal
13.000 ____ 12.500 .... 12.000 .... 11.500 ____ 11,000 ___ 10.500 ____
10.000 9,500 9,000
.... ....
correction factor
. . 1.00 . . . 1.04 . . . 1.08 . . . 1.13 . . . 1.18 . . . 1.24 . . . 1.30 . . . 1.37 . . . 1.44
REPAIR PARTS-TRADE PRICES
Boilers (all fuels^...................................................................................................................................................List Price, less 25% Gas Conversion Burners.......................................................................................................................................List Price, less 25%
For List Prices see ''American-Standard Radiator Heating Repair Parts Catalog" 1956 Edition.
Oil Burners................................................................................................................................................................. List Price, less 25% __________________ For List Prices see "American-Standard Arcofiame Oil Burner Repair Parts Catalog" 1956 Edition.
HH-2
Page 2
04531
American-^Standard
HYDRONIC HEATING
PACKAGED BOILERS GAS FIRED
W*TI
PACKAGED G-2 American-Standard GAS BOILER
Designed and equipped with controls lor forced circulation. Factory asssmbled and crated. Flush or Deluxe Jacket. Sections tested lor 30 lbs. water working pressure. "Eliminaire" (cast-in air eliminator in left end section).
WATER ONLY
packing boiler number
A.(LA. 'MSDBf?t
A.QJL tankiesa
output heater IssWsH
Mm number rating
Mfd,, Nat, Mixed end U Gu; LP-AIr Gas 525,1400 Btu
anat l=BsR
MN?
net rating qft water
Trade Price with standard
equipment
hush leefcet
deluxe Jacket
chimney sixe
diameter height
Inches
feet
approx. shiDoinr
weight
Packaged boilers without tankless heater
G-23-*P G-24-*P G-25-*P G-26-*P G-27*P
60 90 120 150 180
48 72 96 120 144
36 240 $271.00 $285.00 4 20 315
54
360
328.00 342.00
5
20
375
72
480
372.00 386.00
6
20
455
90 600 413.00 427.00 6 20 540
108 720 449.00 463.00 6 20 630
Packaged boilers with factory installed tankless heater
G-24-*PT 90
72 218 2V4
54 360 $361.00 $375.00 5 20 390
G-25*PT 120
96 222 3
72 480 407.00 421.00 6 20 470
G-26*PT 150 120 222 3V4 90 600 448.00 462.00 6 20 550
G-27-*PT 180
144 222 3>/2
108
720 484.00 498.00
6
20
642
AGsllons of water per minute heeled from 40F to 140F with 200F boiler water temperature. *Substitute letter "F" for flush or *`0*` for deluxe jacket.
Standard equipment all boilers: (see options, page 9)
V-600 combination diaphragm gas valve furnished for Natural, Manufactured. Mixed, LP-Air, and LP gas boilers. V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch.. Manual shut-off valve; Pilot cock; Pilot filter (for manufactured gas and S.U.R.); Boiler drain; Draft hood; Insulated jacket; Transformer; ASME relief valve (30 lbs.); Theraltimeter (30 lbs.); Wiring Harness; 1 y<" circulator with piping.
Controls regularly furnished are for 115 volt, 60 cycle current.
Additional standard equipment for boilers with heater:
Tankless heater as listed above. RS-116-F combination immersion control (high and low limits, circulator operation, transformer and built-in relay), CA-520 thermostat.
Additional standard equipment for boilers less heater:
CA-520 thermostat, combination immersion high limit and reverse acting control. Left hand end section without tankless heater opening.
Note: Packaged boilers are shipped with jacket, all controls (except thermostat), cir culator and piping, mam burners and manifold controls and piping factory installed and wired. CA-520 thermostat, manual shut-off valve and relief valve shipped fastened inside boiler crate. Draft hood shipped in separate carton for flush jacketed boiler and G-23-DP.
Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
For ordering instructions for gas boilers, see page 15.
i For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
Page 3
04532
HH-2
PACKAGED BOILERS
GAS FIRED
warn
American-^Standard
HYDRONIC HEATING
PACKAGED G-2 "FPB"AMERiCAN-<$tandard GAS BOILERS
VI lUlUtM----WJ / 1IM1U._H__WfI-U-aalW___tS_WJ Designed and equipped with controls lor forced circulation. Factory assembled and crated. Flush Jacket only. "Eliminaire" (cast-in air eliminator in left end section).
WATER ONLY
paclcagod bolter
numbor
G23-FPB G-24-FPB G-25FPB G-26-FPB G-27-FPB
A.OJL input Mbh
60 90 120 150 180
A.QJL output
Mbh
48 72 96 120 144
not IsBsft rating
Mbh
36 54 72 90 108
not. rating sq.ft watar
240 360 480 600 720
Trado frteo with
qulpmnt
$255.00 283.00 319.00 394.00 431.00
chimnoy also
dlamotor Inchoa
4 5 6 6 6
holght foot
20 20 20 20 20
approx. shipping might
317 377 457 542 632
Standard equipment all boilers:
V-600 combination diaphragm gas valve furnished with Natural. Manufac tured. Mixed gas boilers. V-600 features built-in gas pressure regulator and thermocouple type safety pilot switch. Manual shut-off valve; Pilot cock; Pilot filter (for manufactured gas and S.U.R.); Boiler drain; Draft hood; Insulated jacket; Transformer; ASME relief valve (30 lbs.); Theraltimeter (30 lbs.); Wiring Harness; lYt" circulator.
CB-S80 thermostat, CA-655 immersion limit control.
Left hand end section without tankless heater opening.
Controls regularly furnished are for 115 voit, 60 cycle current.
Not*: Packaged boilers are shipped with jacket, all controls (except thermo stat) . circulator, main burners and manifold controls and piping factory in stalled and wired. CA-580 thermostat, manual shut-off valve and relief valve shipped fastened inside boiler crate. Draft hood shipped in separate carton.
Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of i% for each 1,000 feet above sea level.
For ordering instructions for gas boilers, see page 15.
Optional Equipment: (only those below available)
Runner Type Pilot Ignition for use with listed gases furnished at no charge when specified on order to meet local utility codes. Floor Shield for Combustible Flooring. Add suffix letter "C" to boiler num ber and add 53.00 to Trade Price of boiler. Pilot Filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes. Manual Opening Feature on V-600 gas valve furnished at no additional when specified on order to meet local utility codes. Zone Control Valve Sets available for water boilers, for details and prices, see page 30.
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-2
Pag* 4
04533
American-^Standard
H Y DRONIC HEATING
PACKAGED BOILERS GAS FIRED
WATH
PACKAGED ALL-PURPOSE 2-2 ArERiCAK'<vlsnuai u GAS BOILERS
Designed for forced or gravity circulation. Factory assembled and crated. Deluxe Jacket. Sections tested for 30 lbs. water working pressure. "Eliminalre" (cast-in air eliminator in left end section)
WATER ONLY packaged boiler number
G-23-DPG G-24-DPG G-25-DPG G-26-DPG G-27DPG
A-GJL Input Mbh
A.(LA. output
Mbh
Mfd,, Nat. Mixed and LP Qa* LP-AIrGas $25-1400 Stu
net t = Bs=R rating
Mbh
60 48 36
90 72 54
120 96 72
150 120
90
180 144 108
net rating 4 It water
240 360 480 600 720
Trade Price with
standard equipment
chimney fixe
diameter inches
height feet
$208.50 4 20 265.50 5 20 309.50 6 20 350.50 6 20 386.50 6 20
approx. shipping weight
317 377 457 542 632
Standard equipment: (see options, page 9)
V-600 combination diaphragm gas valve furnished for all gases. V-600 fea tures built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); boiler drain; draft hood; insulated jacket; transformer.
Water only: Theraltimeter; ASME relief valve; CA-655 immersion limit control. Controls regularly furnished are for 115 volt, 60 cycle current Room thermostat not included in above prices. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For elevations above 2.000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet, above sea level. For ordering instructions for gas boilers, see page 15.
For complete information on ratings, see page 2. For discount on repairs, see page 2.
Page 5
04534
HH-2
BOILERS--GAS FIRED
WATtl
American-Standard
HYDRONIC HEATING
G-2 AMERiCAN-^tandard GAS BOILERS
Desigued for iorced circuiation. Flush or Deluxe jacket. Factory Assembled Sections, tested for 30 lbs. water working pressure. "Eliminaire" (cast-in air eliminator in left end section)
WATER ONLY
A.GA. input Mbh
A.GJL tanklest output haatar
Mbh numbar
A l=W=H rating
Mfd.. NaU Mixed and LP Gaa; LP-Air Gat 525-1400 Btu
net l=B=R rating
Mbh
net rating q ft water
Boilers without tankless heater section
G-23-* G 24-* G-25-* G 26-* G27-* G-28-* G-29-*
G-210-* G-211-*
60
90 120 150 180 210 240 270 300
48 72 96 120 144
168 192 216 240
36 240 54 360 72 480 90 600 108 720 126 840 144 960 162 1080 180 1200
Trada Prica with standard
equipment
flush jacket
deluxe jacket
chimney size diameter height
inches feet
approx. shipping
weight
$187.00 $201.00 4 20 275 244.00 258.00 5 20 351 288.00 302.00 6 20 426
329.00 343.00 6 20 488
365.00 379.00 6 20 551 407.00 421.00 7 20 627 449.00 463.00 7 20 695 480.00 494.00 7 20 759 526.00 540.00 7 20 839
Boilers with factory installed tankless heater
G-24-T
90
72 218 2 Vi
54 360 $285.00 $299.00 5 20 363
G-25-T 120
96 222 3
72 480 331.00 345.00 6 20 438
G-26--T 150 120 222 3 Vi 90 600 372.00 386.00 6 20 498
G-27--T 180 144 222 3/2 108 720 408.00 422.00 6 20 562
G-28--T 210 168 222 3*/2 126 840 450.00 464.00 7 20 640
G-29--T 240 192 222 3>/j 144 960 492.00 506.00 7 20 708
G-210--T 270 216 222 3 V2 162 1080 523.00 537.00 7 20 774 G-211--T 300 240 222 3 V2 180 1200 569.00 583.00 7 20 857
Gallons of water per minute heated from 40F to 140F with 200F boiler water temperature. `Substitute letter "F" for flush or `'O'* for deluxe jacket.
Boiler with flush jacket and tankless heater
Standard equipment all boilers: (see options, page 9)
V-600 combination diaphragm gas valve furnished with G-23 through G-29 Natural. Mixed, LP-Air, LP gas boilers and G-23 through G-27 Manufactured gas boilers. V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. V-532 diaphragm gas valve furnished for all gases for sizes not listed above with separate gas pressure regulator (except LP) and Baso switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); Boiler drain; draft hood; insulated jacket; transformer; theraltimeter (30 lbs.); ASME relief valve (30 lbs.).
Additional standard equipment, boilers less heater:
CA-655 immersion limit control.
Left hand end section without tankless heater opening.
Additional standard equipment, boilers with heater:
Tankless heater as listed above. Note: tankless heater is installed at factory in section assembly. RS-116F combination immersion control (high and low limits, circulator operation, transformer and built-in relay).
Controls regularly furnished are for 115 volt, 60 cycle current. Room thermostat not included in above prices. Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2.000 feet, ratings should be reduced at the rate of 4% for each 1.000 feet above sea level. For ordering instructions for gas boilers, see page 15.
a For complete information on ratings, see page 2. For discount on repairs, see page 2.
hh 2
Page 6
04535
American-Standard HYDRONIC HEATING
BOILERS--GAS FIRED STEAM and WATER
G-2
ALL-PURPCSE
AMERICAS-c$Udard
GAS
BO
ikcfia
Designed for water (forced or gravity) or steam.
Flush or Deluxe jacket.
Factory Assembled Sections.
Sections tested for 30 lbs. water working pressure.
"Eliminaire" (cast-in air eliminator in left end sectionl
STEAM ONLY
boiler number
A.G.A. input Mbh
A.GJL. output
Mbh
Mfd,, Nat., Mixed end LP Gee; LPAIr Gee S2S-140Q Btu
G-23-*G G-24-*G G-25-*G G-26-*G G-27-*G G-28-*G G-29 *G G-210'G G-211-*G
60 90 120 150 180 210 240 270 300
48 72 96 120 144 168 192 216 240
net IsBsR retinf
Mbh
36 54 72 90 108 126 144 162 180
eq ft
150 225 300 375 450 525 600 675 750
Trede Price with etenderd
equipment
flueh jacket
deluxe Jecket
$224.00 281.00 325.00 366.00 402.00 444.00 486.00 517.00 563.00
$238.00 295.00 339.00 380.00 416.00 458.00 500.00 531.00 577.00
chimney elze
dlemeter inches
4 5 6 6 6 7 7 7 7
height feet
20 20 20 20 20 20 20 20 20
epprox. hipping weight
287 363 438 500 563 639 707 771 851
WATER ONLY
boiler number
A.GJt. input Mbh
A.GJL output
Mbh
Mfd., Nat., Mixed and LP Gee; LP-Air Gee 525-1400 Btu
net l=B=R rating
Mbh
net rating q ft water
G-23*G G-24-*G G 25-'G G-26-G G-27-*G G-28'G G-29-'G G-210-*G G-211 *G
60 90 120 150 180 210 240 270 300
48 72 96 120 144 168 192 216 240
36 54 72 90 108 126 144 162 180
240 360 480 600 720 840 960 1080 1200
'Substitute letter for flush or "D" for deluxe jacket.
Trade Price with etenderd
equipment
flueh jacket
deluxe jecket
$187.00 244.00 288.00 329.00 365.00 407.00 449.00 480.00 526.00
$201.00 258.00 302.00 343.00 379.00 421.00 463.00 494.00 540.00
chimney size
diameter inches
height feet
4 20 5 20 6 20 6 20 6 20 7 20 7 20 7 20 7 20
approx. shipping weight
277 353 428 490 553 629 697 761 841
Standard equipment: (see options, page 9)
V-600 combination diaphragm gas valve furnished with G-23 through G-29 Natural, Mixed, LP-Air. LP gas boilers and G-23 through G-27 Manufac tured gas boilers. V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. V-532 diaphragm gas valve furnished for all gases for sizes not listed above with separate gas pressure regulator (except LP) and Baso switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); boiler drain; draft hood; insulated jacket; transformer.
Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; external resetting low water cut-off.
Water only: Theraltimeter; ASME relief valve; CA-655 immersion limit control
Controls regularly furnished are for 115 volt, 60 cycle current. Room thermostat not included in above prices. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For altitudes above 2.000 feet, ratings should be reduced at the rate of 49e for each 1,000 feet above sea level. For ordering instructions for gas boilers, see page 15.
For complete information on ratings, see page 2 For discount on repairs, see page 2.
Page 7
04536
HH-2
BOILERS--GAS FIRED
WATTB AND ST1AM
AMERicAx-^taitdard
HYDRONIC HEATING G-2 ALL-PURPOSE American-Standard GAS BOILER
FOR USE WITH "DW" EQUIPMENT
DIRECT TYPE -- Water boilers for hot water supply
Flush or Deluxe jacket. Hydrostatically tested at 200 lbs. Working pressure 80 lbs. Not recommended for use in hard water areas.
boiler number
A.GJL. input Mbh
A.G.A. rating--ffjllon* weter per hour output
Mbh 60* rite 80* rite 100* rite
Mfd^ Nat, Mixed end LP Get; LP-AJr Get 525*1400 Btu
Trede Price with 'DW' equipment
flush Jacket
deluxe Jacket
approx. shipping weight
G-23*G G-24-*G G-25-*G G-26-*G G-27-*G G-28-*G G-29*G G-210-*G G-211-*G
60 90 120 150 180 210 240 270 300
48 72 96 120 144 168 192 216 240
96 144 192 240 288 336 384 432 480
72 108 144 180 216 252 288 324 360
58 86 115 144 173 201 230 260 288
$201.00 258.00 302.00 343.00 379.00 421.00 463.00 494.00 540.00
$215.00 272.00 316.00 357.00 393.00 435.00 477.00 508.00 554.00
277 353 428 490 553 629 697 761 841
'Substitute tetter '*F'* for flush or *'0*' for deluxe jacket.
"DW" standard equipment: (see options, page 9)
In addition to boiler for water with "standard equipment" page 7, "DW" boilers are furnished with Ther-pressure-meter instead of Theraltimeter; 80 lb. ASME relief valve instead of 30 lb. valve; CA-666 immersion operating control for use in storage tank; tank thermometer; name and rating plate for 80 lbs. working pressure.
For ordering instructions for gas boilers, see page IS.
Controls regularly furnished are for 115 volt, 60 cycle current.
Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
FOR USE WITH "IS" EQUIPMENT INDIRECT TYPE --Sfeom boilers for hot water supply
Flush or Deluxe jacket.
boiler number
A.CLA. input
Mbh
A.GJt. ratlng-gallont water per hour output
Mbh 60* rite 80* rite 100* rite
Mfd,, Nat,, Mixed end LP Gat; LP*Air Get 525-1400 Btu
Trade Price with "IS" equipment
fluth lacket
deluxe lacket
approx. thipping
weight
G-23*G G-24*G G-25-*G G-26-*G G-27-*G G-28-*G G-29-*G G-210-*Q G-211-*G|
60 90 120 150 180 210 240 270 300
48 72 96 120 144 168 192 216 240
96 144 192 240 288 336 384 432 480
71 107 143 179 215 251 287 323 359
58 86 115 144 173 201 230 259 288
$234.00 291.00 335.00 376.00 412.00 454.00 496.00 527.00 573.00
$248.00 305.00 349.00 390.00 426.00 468.00 510.00 541.00 587.00
287 363 438 500 563 639 707 771 851
`Substitute letter "F*' for flush or "D" for deluxe jacket.
"IS" standard equipment: (see options, page 9)
In addition to boiler for steam with "standard equipment'' page 7, "IS" boilers are furnished with CA-666 immersion operating control for use in storage tank.
For ordering instructions for gas boilers, see page 15.
Controls regularly furnished are for 115 volt, 60 cycle current.
Ratings shown are for installations at sea level and at elevations up to 2,000 feet For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
For discount on repairs, see page 2. HH-2
Page 8
04537
AMERiCAx-iStandard
HYDRONIC HEATING
BOILERS--GAS FIRED WATER
G-2 OPTIONAL EQUIPMENT
ALL BOILERS (Pages 3 thru S except "Fhb'- Page 4):
Runner type pilot ignition for use with listed gases furnished at no charge when specified on order to meet local Utility codes.
Push button electric ignition for use with listed gases Not available with self-energizing controls. Specify on order and add S11.85 to Trade Price of boiler
Floor shield for combustible flooring. Add suffix letter "C" to boiler number and add $3.00 to Trade Price of boiler.
Pilot filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes.
Manual opening feature on V-600 or V-532 gas valves fur nished at no additional charge when specified on order to meet local utility codes.
Zone control valve sets available for water boilers, for details and prices, see page 30.
PACKAGED GAS BOILERS (Page 3 only): only those options listed above applicable to these boilers.
GAS BOILERS (Page 6 only) for forced circulation:
Tankless heaters No. 226 or 232; available factory installed in place of No. 222, but limited to certain boiler sizes. See table below for I=W=H ratings and applicable boiler size. If desired, specify on order and add to Trade Price of boiler with tankless heater the following charges:
Heater No.
Added Charge
226 ...................................................................... $ 8.00
232 ...................................................................... 12.00
Dual-gas boilers: available for both natural and propane gases. See below for added charges to boiler prices on Page 6.
boiler no.
added charge
boiler no.
added cherge
G-23 G-24 G-25 G-26 G-27
$50.00 52.00 54.00 56.00 58.00
G-28 G 29 G-210 G-211
$60.00 62.00 64.00 66.00
Equipment includes in addition to standard trim two V-532 gas valves, two manifolds with spuds factory assembled, outdoor changeover control.
Room thermostat prices shown on page 32.
PACKAGED ALL-PURPOSE BOILERS (Page 5 only):
Tankless heaters: when boilers (5 thru 7 section) are to be used for forced circulation I=W = H tankless heaters can be installed in opening used for gravity tapping flange cover, but limited to certain boiler sizes. See table below for I=W=H ratings and applicable boiler size Tankless heaters can be ordered shipped separately at following prices:
Heater No.
Trade Price
222 ........................................................ $21.00
226 ..................................................................... 29.00
Self-energizing controls (consists of special gas valve, pilot burner, limit control) for mfd., natural and mixed gas, avail able when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 32.
Room thermostat prices shown on page 32.
ALL-PURPOSE BOILERS (Page 7 only):
WATER BOILERS ONLY:
Tankless heaters: when boilers (5 thru 11 section) are to be used for forced circulation I = W = H tankless heaters can be installed in opening used for gravity tapping flange cover, but limited to certain boiler sizes. See table below for I=W=H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately at following prices:
Heater No.
Trede Price
222 ............................................................. $21.00
226 .......................................................................... 29.00
232 .......................................................................... 33.00
STEAM BOILERS ONLY:
McDonnell-Miller No. 101-24V Electric Water Feeder can be added to the No. 67 Low Water Cut-off furnished with G-2 All-Purpose Steam Boilers to provide Low Water Cut-off and Feeder Combination. If desired specify on order and add $34.57 to Trade Price of Steam Boiler.
Side Outlet Pop Valve may be substituted at no additional charge if specified on order to meet local code requirements.
WATER OR STEAM BOILERS: Dual-gas boilers: available for natural and propane gas. see added charges shown under "GAS BOILERS (Page 6 only) ."
Self-energizing controls (consists of special gas valve, pilot burner, limit control, low water cut:off for steam boilers) for mfd., nat. and mixed gas, available when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 32.
Room thermostat prices shown on page 32.
G-2 Tankless Heaters
boiler number
A.G.A. input Btu/hr.
heater A 218
Rating o
heater a 222
heater A 226
heater A 232
G-24 G-25 G-26 G-27 G-28 G-29 G-210 G-211
90,000 120,000 150.000 180,000 210,000 240,000 270,000 300,000
2 Vi -- -- --
--3
----
-- 3V4 -- --
-- 3 Vi 4
--
--
3 Vi 4 Vi
--
--
3 Vi 4 Vi
4 Vi
--
3>/z 4 Vi
4 Vi
--
3 Vi 4 Vi
5
Heaters have been tested with G-2 boilers and are available only factory installed in all models m the above sizes except for the all purpose boiler*.
e Gallons water per minute heated from 40*F to 140*F with 200*F boder water temperature.
Last two digits designate lineal feet of Tru Fin tubing in heater cod.
Page 9
04538
Hh 2
B01URS-GAS FIRED
SHAM AMO WATKt
STEAM ONLY
belter umber
6-403 6-404 6-405 6406 6-407 6-408 6-409 64010
WATER ONLY
belter
6403 6404 6405 6406 6407 6408 6409 64010
STEAM ONLY
bolter amber
6403 6404 6405 6406 6407 6408 6409 64010
WATER ONLY
bolter auwtiaj
6403 6404 6405 6406 6407 6408 6409 64010
A.CJL lapt
Utah
150 225 300 375 450 525 600 675
1CJL tagst
MM
150 225 300 375 450 525 600 675
A.G.A. Input
Mbb
120 180 240 300 360 420 480 540
A.6X lopot
Mbb
120 180 240 300 360 420 480 540
HYDRONIC HEATING
0-40
AMERiCAN'<$tandard OA8 BOILERS
For Built-In Water Heater Arrangement, ee page ' *
Deluxe Jacket
Tested and equipped tor 50 lbs. water wining "Eliminaire" (cast-in air eliminator In left end see on .
FOR NATURAL, MFD., MIXED, OASES ONLY
A.GJL natpat
Mbit
120 180 240 300 360 420' 480 540
OOt Is* Ul rating
Mbb
90.0 135.0 180.0 225.1 270.1 315.1 360.1 405.1
sq. ft
375 563 750 938 1125 1313 1500 1688
irada ffka with itaadari
$380 00 477.00 577.00 697.00 787.00 887.00 907.00 1057.00
chimney tixe
diem. iiicM* hi ft.
6 20 7 20 7 20 8 20 8 20 9 20 10 20 10 20
approx.
weight
858 1027 1195 1370 1544 1713 1880 2050
A.CJL fltpBt Mbb
Mt lalsR nti*f Mbb
rating tg. ft water
120 90.0 600
180 135.0
900
240 180.0 1200
300 225.1 1500
360 270.1 1800
420 315.1 2100
480 360.1 2400
540 405.1 2700
FOR LP AND LP-AIR
A.6.A. ootpot
nit 1= B=P rating
Mbb Mbb sq. ft
96 72.0 300
144 108.0
450
192 144.0
600
240 180.0
750
288 216.1
900
336 252.1 1050
384 288.1 1200
432 324.1 1350
Train Wte wit* standard
aalaaiaaf
chlmnoy tilt diem. IbcMk ht It.
$34.1.00
6 20
440.00
7 20
540.00
7 20
600 00
8 20
750 00
8 20
850 00
9 20
910 00
10 20
1070 00 10 20
GAS ONLY
Trad# Prleo wit*
chimney size diam. inches ht. ft.
$380.00
6 20
47/ 00
7 20
577 00
7 20
697.00
8 20
787.00
8 20
887.00
9 20
q|i/ 00
10 20
1057 00 10 20
epprex. skipping weight
827 998 1162 1349 1517 1686 1856 2026
approx. shipping weight
858 1027 1195 1370 1544 1713 1880 2050
A.6JL ootpot
Mbb
96 144 192 240 288 336 384 432
Oft i=e=* ratine Mbb
not rating aq. ft waitr
Traaa Prka With itetfartf
t0iipo,*B*
chimney size dlan. Inchat ht. ft.
approx. shipping weight
72.0 108.0 144.0 180.0 216.1 252.1 288.1 324.1
480
720 960 1200 1440 1680 1920 2160
^
$34100 440.00 54000
600 00
750 00 880 00
980 00 1070.00
6 7 7 8 8 9 10 10
20 20 20 20 20 20 20 20
827 998 1162 1349 1517 1686 1856 2026
Standard equipment include.! (see options, pages 11 and 15)
Baso* ombiMtion^ilot switch* and valve with auxiliary Base pilot.valves Optional other gases at no additional charge-. manual shut-off valve; pilot filter (mfd gas and SUR); gas pressure regulator (except for LP gas); boiler drains and pilot cocks, insulated jacket; draft hood; water heater opening cover plates.
Iteam |?ijge; ASME safety valve: 4.V-BA-1 boiler pressure limit control; gauge glass
with trimmings; external resetting lew w'ater out-off.
TTieraUimeter; ASME relief valve for SO lbs.; CA-655 immersion limit control. Controls regularly furnished are for US volt, 60 cycle current. Ratings shown are for installations at sea level nd at elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. Room thermostat not included in above prices. For complete information on optional equipment, see pages 11 and 15. For ordering instructions for gas boilers, see page 15.
i For complete information on boiler ratings, see page 2. For discount on repairs. >ee page 2.
Pag* 10
04539
HYDRONIC HEATING
BOILERS-GAS FIRED
STEAM ANO WATER
G-40 OPTIONAL EQUIPMENT
BOILERS WITH TANKLESS HEATERS: water {for forced circulation) and steam boilers can be furnished with tankless heaters. Some heaters are limited to certain boiler sizes as shown in ratings table below.
Tsnkless heaters with controls for water boilers: RS-116-F packed in trim box in place of CA-655 for standard equipment.
Tankless heaters with controls for steam boilers: additional CA-666 immersion operating control packed in trim box.
If tankless heaters with controls are desired, specify on order with boiler and add to Trade Price of boiler with standard equipment the following charges.
Tankless heaters less controls will be furnished when specified at the Trade Prices shown below for heaters only.
HEATER HO.
218 222 226 232 445
HEATER WITH CONTROLS
Water
Steam
$43.00 45.00 53.00 57.00 74 00
$29.00 31.00 39.00 43.00 60.00
HEATER ONLY
Water er Steam
$19.00 21.00 29.00 33.00 50.00
Water flow regulators sized for tankless heater involved will be fur nished with heater when specified on order to meet local Utility require ment at S2.00 Trade Price additional charge per heater.
Factory assembled sections: G-403 through G-406 can be shipped with sections factory assembled when specified on order. If desired less tankless heater, add $15.00 to Trade Price of boiler. If desired with fac tory installed tankless heater, specify heater number, and add $15.00 plus price of heater to Trade Price of boiler.
Dual Gas Equipment: available with steam or water boilers for use
with Natural and Propane gases only, in addition to standard trim, dual gas equipment includes tube withm a tube manifold, two V-532 gas valves, gas pressure regulator (natural gas only), two manual shut off valves, ribbon burners, 100% shut-off (consists of Baso combination pilot valve and switch with auxiliary Baso pilot valves), pilot cock, outdoor thermostatic adjustable changeover control. Boiler selection should be based on the A.G.A. and l=B=R ratings shown for LP gas. If desired specify on order and add to Trade Price of boiler with standard trim the following charge:
Boiler Number
G-403 G-404 G-405 G-406
Add to Boiler Trade Price
$60.00 62.00 64.00 66.00
Boiler Number
G-407 G-408 G-409 G-4010
Add to Roller Trade Price
$68.00 70.00 72.00 74.00
Electronic Control Systems: available with steam or water boilers. If
desired refer to page 15 for complete details and additional Trade Price charges.
Tri-cock tappings and valves: if desired for steam boilers to meet local code specify on order and add $4.00 to Trade Price of steam boiler.
Seif-energizing controls: available for steam or water (gravity) (ess tankless heater for natural and mixed gases only. Equipment includes special gas valve, pilot burner, limit control, low water cut-off for steam boilers. Furnished at no additional charge when specified on order Special room thermostat required, for Trade Price see Page 32.
McDonnell-Miller No. 101-24 Volt Electric Water Feeder can be added to No. 67-GAR low water cut-off furnished with G-40 Steam Boilers to provide low water cut off and feeder combination, if desired specify on order and add $34.57 to Trade Price of steam boiler.
McDonnell-Miller No. 47-2 low water cut-off and feeder combination may be specified in place of regularly furnished No. 67-GAR for steam boilers. If desired specify on order and add $33.00 to Trade Price of steam boiler.
McOonnefl-Milier No. 247-2 low water cut-off and feeder combination for water boilers is available with G-40 Water Gas Boilers when specified on order. Add to the Trade Price of the water boiler with regular equipment the current Trade Price of this item shown in the current McDonnell-Miller Price Sheet.
Runner type pilot ignition: all sizes of G-4Q are available with Runner type pilot ignition for mfd.. nat- and mixed gas non-100% shut-off at no additional charge when specified on order to meet local Utility codes.
Push button electric ignition: all sizes of G-40 are available with push button electric ignition for use with mfd., nat. and mixed gas non-100% shut-off and will be furnished when specified on order at $11.65 added charge.
Pilot filters for G-40 for natural and mixed gases available at no addi tionai charge when specified on order to meet local utility codes.
Room thermostats available at Trade Prices shown on Page 32.
"IS" Equipment: G-40 Gas Boilers can be furnished for use with In direct Steam Hot Water Supply systems. CA-666 immersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on Page 32.
V-532 Diaphragm Gas Valve without manual opening may be substi tuted for V-531 Gas Valve with manual opening at no additional charge, if desired, specify on order.
Side Outlet Steam Pop Valves may be substituted at no additional charge if specified on order to meet local code requirements.
Jacket Extension: covers all controls on left end of boiler. If desired, specify on order and add $25.00 to Trade Price of Boiler.
G-40 Tankless Heater Ratings (Gallons per minute9)
Boiler
G-403 G-404 G-403 G-408 G-407 G-408 G-409 6-4010
HEATER 218
Steam
Water
34 3tt 4 31* 4 3 >* 4 3Vj 4 3Vfc 4 3** 4 3V* 4
HEATER 222
Steam
__ 4 4 4 4 4 4 4
Water
_
4Ut 4<*
4Va 4i* 4Vz 4i*
HEATER 226
Steam
Water
----
---- 5Vi 6 5>* 6
6 6Va 6 61* 6 61* 6 6i*
HEATER 232
Steam
_
-- -- -- 7 71* 71* 71*
Water
_
-- -- -- 7i* 8 8 8
HEATER 445
Steam
Water
----
---- ---- ---- ---- 8V5 9 81* 9 81* 9
*Gallont of water pr m/nufa railed from 40F. fo I40QF. Lori fwo digift of heater number* indicofe lineal feaf of Tru-fin tubing in haofer coil.
Page 11
HH 2
04540
jAMEWCAJi*<$tandard HYDRONIC HE ATI NO
G-60 AMERiCAN-fStandard GAS BOILER
for Natural, Mixed, Manufactured Gates
Jacketed. Tested end equipped for 50 lbe. water working pressure. Available tor 80 lbs. working pressure on special order.
boiler number
G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041
WATER ONLY
A.O. input
Mbh
725 870 1015 1160 1305 1450 1740 2030 2320 2610 2900 3045 3480 3915 4350 4640 5220 5800
A.O. output
Mbh
580 696 812 928 1044 1160 1392 1624 1856 2088 2320 2436 2784 3132 3480 3712 4176 4640
not 1= 5=R ratine
Mbh
sq ft
435.1 522.1
609.2 696.2 783.2 870.2 1054.5 1248.3 1438.8 1621.1
1801.2 1891.3 2161.5 2430.1 2701.9 2880.4 3245.3 3602.5
1813 2176 2538 2901 3263 3626 4394 5201 5995 6755 7505 7880 9006 10126 11258 12002 13522 15010
Trade Price with standard equipment
$ 998.00 1155.00 1320.00 1498.00 1675.00 1820.00 2129.00 2445.00 2748.00 3057.00 3366.00 3570.00 4004.00 4333.00 4932.00 5221.00 5840.00 6458.00
chimney size
diem. in.
ht ft
ii 20
12 20
13 20 13 20 14 20 15 20 15 20 16 20 16 30
17 30 18 30 19 30 20 30 21 30 22 30 24 30 26 30 26 30
approx* shipping weight
2751 3151 3537 3934 4346 4739 6069 6855 7640 8523 9312 10154 11361 12648 13841 15068 16720 18346
boiler number
G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041
A.G.A. input
Mbh
725 870 1015 1160 1305 1450 1740 2030 2320 2610 2900 3045 3480 3915 4350 4640 5220 5800
A.G.A. output
Mbh
580 696 812 928 1044 1160 1392 1624 1856 2088 2320 2436 2784 3132 3480 3712 4176 4640
net l=B=R rating Mbh
435.1 522.1 609.2 696.2 783.2 870.2 1054.5 1248.3 1438.8 1621.1 1801.2 1891.3 2161.5 2430.1 2701.9 2880.4 3245.3 3602.5
net rating sq ft water
2900 3480 4060 4640 5220 5800 7030 8320 9590 10805 12010 12610 14410 16200 18010 19205 21635 24015
Trade Price with standard equipment
$ 961.00 1118.00 1283.00 1461.00 1638.00 1783.00 2092.00 2408.00 2711.00 3020.00 3329.00 3533.00 3967.00 4296.00 4895.00 5184.00 5803.00 6421.00
chimney size
diam. In*
ht ft
a 20 12 20 13 20 13 20 14 20 15 20
15 20 16 20
16 30 17 30 18 30 19 30 20 30
21 30 22 30 24 30 26 30 26 30
approx. shipping weight
2741 3141 3527 3923 4335 4728 6049 6835 7620 8503 9292 10139 11334 12616 13809 15036 16690 18316
Standard equipment includes: (see options, pages 14 and 15)
V-531 diaphragm gas valve with manual opening feature; Baso automatic pilot switch for non-100% shut-off (100% shut-off controls consisting of Baso combination pilot switch and valve with auxiliary Baso pilot valves, optional at no additional charge); manual shut-off valve; pilot filter (mfd gas and SUR); gas pressure regulator; boiler drains and pilot cocks; insulated jacket; draft hood.
Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; resetting low water cut-off.
Water only: Theraltimeter and ASME relief valve for 50 lbs.; CA-655 immersion limit control.
Controls regularly furnished are for 115 volt. 60 cycle current.
Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
Room thermostat not included in above prices.
For complete information on optional equipment, see pages 14 and 15.
For ordering instructions for gas boilers, see page 15.
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-2
Pag* 12
04541
Ame rican Standard
HYDRONIC HEATING
BOILERS--GAS FIRED
ITtAM AMD WATIK
G-60 AMERiCAN-<$tandard GAS BOILER
for LP and LP-Air Gas only
Jacketed. Tested and equipped for 50 lbs. water working pressure. Available for 80 lbs. working pressure on special order.
STEAM ONLY
beiler number
G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G 6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041
WATER ONLY
boiler number
G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041
A.G.A. input
Mbh
650 780 910 1040 1170 1300 1560 1820 2080 2340 2600 2730 3120 3510 3900 4160 4680 5200
A.G.A. input Mbh
650 780 910 1040 1170 1300 1560 1820 2080 2340 2600 2730 3120 3510 3900 4160 4680 5200
A.G.A. output
Mbh
520 624 728 832 936 1040 1248 1456 1664 1872 2080 2184 2496 2808 3120 3328 3744 4160
A.G.A. output
Mbh
520 624 728 832 936 1040 1248 1456 1664 1872 2080 2184 2496 2808 3120 3328 3744 4160
not l=B sR rating
Mbh
390.1 468'. 54C 624.2 702.2 780.2 936.2 1108.1 1282.0 1452.3 1614.9 1695.7 1937.9
2180.1 2422.4 2585.4 2903.7 3229.8
sq. ft
1625 1950 2276 2601 2926 3251 3901 4617 5342 6051 6729 7065 8075 9084 10093 10773 12099 13458
net l=B=R rating Mbh
390.1 468.1 546.1 624.2 702.2 780.2 936.2 1108.1 1282.0 1452.3 1614.9 1695.7 1937.9 2180.1 2422.4 2585.4 2903.7 3229.8
net rating q. ft. water
2600 3120 3640 4160 4680 5200 6240 7385 8545 9680 10765 11305 12920 14535 16150 17235 19360 21530
Trade Price with
otandard equipment
$ 998.00 1155.00 1320.00 1498.00 1675.00 1820.00 2129.00 2445.00 2748.00 3057.00 3366.00 3570.00 4004.00 4333.00 4932.00 5221.00 5840.00 6458.00
chimney *lie
dlam. in.
ht. ft.
ii 20 12 20 13 20 13 20 14 20 15 20 15 20 16 20 16 30 17 30 18 30 19 30 20 30 21 30 22 30 24 30 26 30 26 30
Trade Price with
etandard equipment
$ 961.00 1118.00 1283.00 1461.00 1638.00 1783.00 2092.00 2408.00 2711.00 3020.00 3329.00 3533.00 3967.00 4296.00 4895.00 5184.00 5803.00 6421.00
chimney size
diam. In.
ht. ft.
ii 12 13 13 14
15 15 16 16 17 18
19 20 21 22 24 26 ` 26
20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30
"*
approx. chipping
weight
2751 3151 3537 3934 4346 4739 6069 6855 7640 8523 9312 10154 11361 12648 13841 15068 16720 18346
2741 3141 3527 3923 4335 4728 6049 6835 7620 8503 9292 10139 11334 12616 13809 15036 16690 18316
i
a
la
l*
Standard equipment includes: (see options, pages 14 and 15)
V-531 diaphragm gas valve with manual opening; 100% shut-off <100% shut-off controls tor LP-air and LP gases consists of Baso combination pilot switch and valve with auxiliary Baso pilot valves); manual shut-off valve; gas pressure regulator (except for LP-gas); boiler drains and pilot cocks; insulated jacket; draft hood.
Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; resetting low water cut-off.
Water only:
Theraltimeter and ASME relief valve for 50 lbs.; CA-655 immersion limit control. Controls regularly furnished are for 115 volt, 60 cycle current. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For eleva tions above 2.000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. Room thermostat not included in above prices. For complete information on optional equipment, see pages 14 and 15. For ordering instructions for gas boilers, see page 15.
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
Page 13
04542
HH-2
BOILERS--GAS FIRED WATtft AND ftTiAM
American-Standard
HYDRONIC HEATING
G-60 OPTIONAL EQUIPMENT
Push button electric ignition: aii size* ul G-60 are avaiiaoic with push button electric ignition for use with mfd., nat. and mixed gas non-100'/* shut-off. and will be furnished when
specified on order at the following added charges:
boiler size G-606 thru G-6011
added charge $11.85
G-6013 thru G-6021
23.70
G-6022 thru G 6031
35.55
G-6033 thru G-6041
47.40
Pilot filters for G-60 for natural and mixed gases available at no additional charge when specified on order to meet local utility codes.
Room thermostats available at Trade Prices shown on page 32.
McDonnell-Miiler Low Water Cut-off No. 67-AR external type can be substituted for the regular No. 69 Low Water Cut-ofT on G-60 steam gas boilers at no additional charge. If desired, specify on order.
"IS" Equipment: G-60 gas boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. CA-666 im mersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade
Price as showrt on page 32. This control operates gas valves on boiler electrically as required Shipping weights of gas boilers for hot water supply are same as shown for regular
gas boilers.
Tri-cock tappings and valves; if desired for steam boiler to meet local code specify on order and add $4.00 to Trade Price of steam boiler.
G-60 available tested at 80 lbs. water working pressure when specified on order. Add $3 00 per section to Trade Price of
water boiler.
McDonneii-tf iiier No. 47*2 and 51*2 Luw VVaier Cui-oii omj Feeder combinations are available with G-60 steam gas boil ers in place of regularly furnished No. 69 low water cut-off. when specified on order, at the following added charges to Trade Price of steam boilers with regular equipment:
boiler number
G 606 thru G-6011
G-6013 thru G-6041
combination number
47-2
51 2
added charges
$33.00
46.00
McDonnell-Miller No. 247*2 and 51*2 low water Cut-off and Feeder combinations for water boilers are available with G-60 water gas boilers when specified on order. Add to the Trade Price of the water boiler with regular equipment the current Trade Price for these items shown in the current McDonncllMiller price sheet.
V-532 Diaphragm gas valve without manual opening may be substituted for V-531 Gas valve with manual opening at no additional charge. If desired specify on order.
Side Outlet Steam Pop Valves may be substituted at no addi tional charge if specified on order to meet local code require ments.
G-60 external water heater tappings: maximum size all sec tions 1 tV*. Add to Trade Price of boiler $2.00 per section tap ping and $2.00 per jacket tapping.
G-60 Right end steam trim tappings for pressure gauge and water column gauge glass furnished when specified on order at Trade Price addition charge of $10.00 per boiler.
G-60 DUAL GAS BOILERS Natural and Propane Gases
G-60 steam or water boilers are available with dual gas equipment using natural and propane gases. If desired specify on order and add the charge shown below to boiler with standard equipment. Selection of the boiler should be based on the A.G.A. and I=B = R ratings shown on page 13.
boiler number
add to boiler Trade Price
boiler number
add to boiler Trade Price
G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017
$ 95.00 100.00 105.00 110.00 115.00 120.00 145.00 165.00 185.00
G-6019 G-6021 G 6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041
$205.00 225.00 240.00 270.00 300.00 350.00 375.00 445.00 480.00
Dual gas equipment:
In addition to boiler with standard trim dual gas boilers include:
Two V-532 diaphragm gas valves; two manifolds; gas pres sure regulator 'natural gas onlyi; manual shut-off valves.
ribbon burners; 100Cc safety shut-off 'consists of Baso com bination pilot switch and valve with auxiliary Baso pilot valves), pilot cock; outdoor thermostatic adjustable change over control
Room thermostat not included in above prices
For ordering instructions for gas boilers see page 15
HH 2
Page 14
04543
American-Standard
HYDRONIC HEATING
BOILR,ST"AS F,RH>
G-40 AND G-60 ELECTRONIC
Panel System EPG-O: Specifically designed for Factory Mutual <F.M ) and Factory Insurance Association (F.I.A.) installa tions. Provides electronic supervision of each primary pilot
each combustion chamber (I to 4) and intermittent eieeti te ignition of all pilots. Complete automatic operation of boiler. 100% safety shut-off Equipment includes: one main control panel with 1 to 3 auxiliary panels pre-wired and factory assembled: Q-179-A flame rod and electric ignition pilots; ignition transformer; V-495-B pilot solenoid valves; RA-890-E electronic relay for each panel with 8 second response timing and alarm contacts. See additional charges below.
CONTROL PANEL SYSTEMS
off. Available for all gases. Electronic supervision of a pri mary pilot and thermocouple supervision of all auxiliary pilots.^Main burner and pilot burner gas supply turned off or pilot f.iluie. Cuminuous flame pilot operation Equipment includes: one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel; Q-179-B flame rod primary pilot(s) with special adapter for thermocouple, Baso auxiliary pilot burners; Baso 817-F-ll pilot valves with thermocouples; RA-890-E elec tronic relay for each panel with 8 second response timing and alarm contacts See additional charges below.
Panel System EPG-1: Provides manual ignition, non-100% shut-off. Available for Natural. Mixed and Manufactured Gas only Electronic supervision of a primary pilot and thermo couple supervision of all auxiliary pilots. Main burner gas supply only turned off on pilot failure. Continuous flame pilot operation. Equipment includes: one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel; Q-179-B flame rod primary pilot (s); Baso auxiliary pilot burners: Baso 850-1 switches with ther mocouples; RA-890-E electronic relay for each panel with .8 second response timing and alarm contacts. See additional charges beltrtv.
Panel System EPG-2: Provides a manual ignition, 100% shut-
Panel System EPG-3: Provides intermittent electric ignition on a primary pilot and continuous flame auxiliary pilots with 100% shut-off Available for all gases. Electronic supervision of a primary pilot and thermocouple supervision of auxiliary pilots. Main burner and pilot burner gas supply shut-off on pilot failure. Equipment includes: one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel; Q-179-A flame rod and electric ignition primary pilotis); primary pilot solenoid valveisi V-495-B; Baso auxiliary pilot burner; Baso 817-F-ll pilot valves with thermocouples; 6000 volt secondary ignition transformertsi; RA-890-E electronic relay for each panel with 8 second response timing and alarm contacts. See additional charges below
ADDITIONAL CHARGES-Trade Price
Specify on order type of system desired, as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment
Panel System EPG-O
boiler number
added charge
Panel System EPG-1
boiler number
added charge
* Panel System EPG-2
boiler number
added charge
Panel System EPG-3
boiler number
added charge
G- 403 thru 407 G- 408 thru 4010 G- 606 thru 6011 G-6013 thru 6021 G-6022 thru 6031 G-6033 thru 6041
$163.00 177.00 177.00 359.00 538.00 718.00
G- 403 thru 4010 $150.00
G- 606 thru 6037
150.00
G-6041
281.00
Mfd. gas only:
G-6028 thru 6037 $281.00
G- 403 thru 4010 $171.00
G- 606 thru 6037
171.00
G-6041
283.00
Mfd. gas only.
G-6028 thru 6037 $283.00
G- 403 thru 4010 $185.00
G- 606 thru 6037
185.00
G-6041
334.00
Mfd. gas only:
G 6028 thru 6037 $334.00
Panel System EPG-1 available for Natural. Mixed and Manufactured gases only. Balance for all gases.
G-40 AND G-60 ELECTRONIC CONTROL SYSTEMS (less Panels)
The following systems <EG-0. EG-1. EG-2 and EG-3) are also avatlable, but do not include factory wired and assembled control panel. These systems provide the same function and
are equipped with the same basic parts (less panel) as described for EPG-O. EPG-1. EPG-2. and EPG-3.
System EG-0: System EG-1: System EG-2: System EG-3:
(Samefunction as EPG-O less panel ) (Samefunction as EPG-1 less panel.) (Samefunction as EPG-2 lesspanel.) (Samefunction as EPG-3 less panel.)
See additional charges below See additional charges below See additional charges below. See additional charges below.
ADDITIONAL CHARGES-Trade Price
Specify on order type of system desired, as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment
Control System EG4)
boiler number
added charge
G- 403 thru 407 G- 408 thru 4010 G- 606 thru 6011 G-6013 thru 6021 G-6022 thru 6031 G-6033 thru 6041
$108.00 140.00 140.00 280.00 420.00 560.00
Control System EG-1
boiler number
added charge
G- 403 thru 4010 $ 86.00
G- 606 thru 6037
86.00
G-6041
173.00
Mfd. gas only:
G-6028 thru 6037 $173.00
Control System EG-2
boiler number
added charge
G- 403 thru 4010 $ 96.00
G- 606 thru 6037
96.00
G-6041
175.00
Mfd. gas only:
G-6028 thru 6037 $175.00
Control System EG-3
boiler number
added charge
G- 403 thru 4010 $113.00
G- 606 thru 6037
113.00
G-6041
227.00
Mfd. gas only:
G-6028 thru 6037 $227.00
Control System EG-1 available for Natural. Mixed and Manufactured gases only. Balance for all gases
Ignition Cable: Trade Price per foot Flame rod wire: Trade Price per foot
$0.70 $0.40
Orders must specify:
GAS BOILERS--Instructions for Ordering
1 1 > Complete Boiler Number. i2> Steam or water '31 Equipment desired- Regular. "DW" or IS", etc
Type of gas ' If LP-gas. whether butane or propane 1
15 Btu `heal value of gas' and specific gravity 16> Elevation al point of installation if in excess uf 2 OuO
feet T > Pressui e available at outlet of gas meter
Page 15
HH 2
04544
INSHOT GAS BURNERS
American-Standard
H Y D R O N I C HEATI N G
INSHOT GAS CONVERSION BURNER -- Factory assembled
control! regularly furnished are for 115 volt, 60 cycle current
A.G.A. ratlngi-Btu Input par hour
modal numbtr IN-150
IN-245
IN-275
Inputs
(min (max
fmin (max
{min (max
Nat and Mxd. Gaa
80,000 150,000
130.000 245.000
130.000 275.000
Mfd. Gas
80,000) 150,000)
not ) available)
not ) available)
Trada Prfca with standard aqulpmant
Net end Mxd. Get
Mfd. Gas
$68.00
$73.25
approx. walght
20
$74.50 $83.75
not available
not available
21 21
Gas valva sizat: l/tm for IN150 Nat and Mxd. Gat, for all othar tlzat. Shoot motol mounting plata roquirod for all othar convarsiont axcapt Arcoleadar and Arcoliner Wat Base oil boliert. This plata to ba fumishad by installar. If CA-520 tharmostat not desired, deduct $7.74 from Trade Price shown above.
INSHOT GAS BURNER MAXIMUM INPUTS FOR ARCOLEADER AND ARCOLINER BOILERS
Burner Model: Type of gas:
IN-150 Nat. Mxd. Mfd.
IN-245 Nat. Mxd. only
IN-275 Nat. Mxd. only
IN-275 Nat. Mxd. only
Maximum Gas Inputs -- Btu/hr.
Boiler Model
3 eectlon
4 lection
5 eectlon
6 eectlon
Arcoleader Arcoliner
115.000 120.000
160,000 170,000
210,000 200,000
260,000
6-Section Arcoliner Is not recommended for (as firing
Standard equipment Includes:
CA-520 thermostat. Runner pilot ignition. Manual shut-off valve. Control housing. Stainless steel flame spreader. Pilot throttling valve. Pilot filter--with mfd. gas burners only. Two main burner orifices: one drilled for minimum input, factory installed; the second, also drilled for minimum input, is provided.
Models IN-150 and IN-245 V-600 series combination gas valve, pressure regulator and safety pilot switch, transformer, manual opener.
Model IN-275 General Controls KX3H quiet solenoid gas valve, plug-in safety pilot switch, transformer, manual opener. Gas pressure regulator.
Optional equipment:
Self-energizing control,! General Controls T80-A thermostat, B-60 gas valve and PG9 pilot generator-if desired, specify on order:
Bumar Modal
oft?.
Trade Charge
IN-150 IN-150 IN-245 IN-275
Nat and Mxd. Mfd.
Nat. and Mxd. Nat. and Mxd.
No extra cost Add $2.75 Add 2.75
No extra cost
Select from list below special limit control which must be used with telf-energlzlRg controls.
100% safety shut-off, all models, specify on order and add $2.00 to Trade Price above.
Pilot filter--regularly furnished only for Mfd. gas. If desired for Nat. and Mxd. gas, specify on order and add $1.50 to Trade Price above.
Optional controls for self-energizing (millivolt) application:
Number L-52A10A1A L-39PA412
S45A1A3A3 S45A5AM3
Description
General Controlsimmersion limit control.................. General Controls pressure boiler limit control, scale
0-10 lbs............................................................................... General Controls warm air limit control.................... General Controlsfan and limit control.......................
For other optional controls, see pege 32.
Trade Price $10.75
11.44 3.30 6.71
Orders must specify:
GAS CONVERSION BURNERS--Instructions for Ordering
1. Type of gas. 2. Btu (heat value of gas) and specific gravity. For discount on repairs, see page 2.
- 3. Pressure available at outlet of gas meter. 4. Optional controls, if desired.
HH-2
Page 16
04545
AMERiCAN-<Standard
HYDRONIC HEATINO
packaged
BOILER-BURNER UNITS
wait*
ARCOLEADER PACKAGED BOILER-BURNER UNITS
Designed and equipped with tonfrels for forced clreulstien.
Factory assembled and crated. Wet base construction. Flush jacket.
WATER packaged unit numbtr
groti l=BsR output
Mbh
IsBsR bumar capacity
gph
tanldaaa haatar iiumbir
A IsWsH
rating
nat IsBsR rating
Mbh
nat rating tq ft watar
Trad# Plica with standard aqulpmant
chlmnay alza
approx. shipping weight
Packaged units less tankless heater
A1-3P A1-4-P A1-5-P
100 136 173
0.95 1.30 1.65
75.0 102.0 129.8
500 680 865
$447.00 498.00 569.00
8x8x 15 8x8x 15 8x8x 15
661 811 959
Packaged units with factory installed tankless heater
A1-3-PT A1-4-PT A1-5-PT
100 0.95 732 33/i 136 1.30 732 4V4 173 1.65 743 5V4
75.0 102.0 129.8
500 680 865
$469.00 523.00 613.00
*Nozzle sizes, gph, furnished with Arcoleeder packiged units: Al'3'P. 0.90-70* H: A1-4-P. 1.25-60* H; A1-5-P, 1.50-60* S.
A Gallons of water par minute heated from 40F to 140F with 2OOF boiler water temperature.
8x8x 15 8x8x 15 8x8x15
673 824 991
Standard equipment all Units: (see options, page 19)
Model DH-5 Arcoflame oil burner with sling mounting for front firing. CA-701 primary con trol. Draft stabilizer. ASME relief valve. Heat Lib-O-Rator high temperature steel combus tion chamber. IV," circulator with piping. Wiring harness. Drain valve. Theraltimeter. Motors and controls regularly furnished are for 115 volt, 60 cycle current. Additional standard equipment for units with factory installed heater Built-in tankless heater as listed above.
No. 36 Arcoflame control set (CA-520 thermostat, CA-610 combination immersion controlhigh, low limit, circulator control, built-in relay) and nozzle.
Additional standard equipment for units less heater: No. 33 Arcoflame control set (CA-520 thermostat, CB-614 combination immersion controlhigh limit and circulator control) and nozzle. Heater opening cover plate.
NotirUnits are shipped with flush jacket and with all electrical controls (except thermostat). circulator and piping, factory installed and wired. Arcoflame oil burner shipped separately. Draft stabilizer, relief valve and thermostat are secured inside boiler crate.
For complete information on boiler ratings, see page 2. For discount on repairs, see Dage 2.
Pig, 17
04546
HH-2
boiler-burner units OIL FIRED BOILERS
WATU
Ame mcAN'^tandard
HYDRONIC HEATING
ARCOLEADER BOILER-BURNER UNITS
Designod and equipped with controls for forced circulation.
Wet base construction. VI ith jacket Factory assembled sections.
WATER
b<lir> burner
unit number
cross l=B=R output
Moh
l=B=R burner capacity
IJ>*
tankless heater number
|=WA=Hratine
Units less factory installed tankless heater
A1-3-B A1-4-B A1-5-B A1-6-B A1-7-B
100 0.95 136 1.30 173 1.65 208 1.95 244 2.30
Units with factory installed tankless heater
A1-3-BT
A1-4-BT A1-5-BT A1-6-BT
A1-7-BT
100 0.95 732 3y,
136 1.30 732 4/ 173 1.65 743 5 Vi 208 1.95 743 6 244 2.30 743 6
net l=B=R rating
Mbh
75.0 102.0 129.8 156.0 183.0
75.0 102.0 129.8 156.0 183.0
net rating sq ft water
500 680 865 1040 1220
500 680 865 1040 1220
Trade Price with standard equipment
$349.00 412.00 480.00 544.00 612.00
$384.00 447.00 534.00 598.00 666.00
chimney size
8x8x 15 8x8x 15 8x8x 15 8x8x 15 8x 12 x 15
8x8x 15 8x8x 15 8x8x 15 8x8x 15 8x 12 x 15
appro*. shipping
weight
586 726 882 1051 1197
596 740 906 1087
1233
Nozzle sizes, sph. furnished with Arcoleader boiler-burner units: Al-3-8, 0.90-70* H; A1-4-B. 1.25-60* H: A1-5-B. 1.50-60* S: A1-6-B, 1.75-60* S: A1-7 B, 2.00-60* S.
Gallons of water per minute heated from 40F to 140F with 2OOF boiler water temperature.
Standard equipment all Units: (see options page 19)
Model DH-5 Arcoflame oil burner with sling mounting tor front firing. CA-701 primary con trol. Draft stabilizer. ASME relief valve. Theraltimeter. Heat Lib-O-Rator high temperature steel combustion chamber.
Motors and controls regularly furnished are for 115 volt, 60 cycle current.
Additional standard equipment for units with tankless heaters: Tankless heater as shown above factory installed in section assembly. No. 36 Arcoflame control set (CA-520 thermostat, CA-610 combination immersion controlhigh, low limit, circulator control, built-in relay) and nozzle.
Additional standard equipment for units less heater No. 33 Arcoflame control set (CA-520 thermostat, CB-614 combination immersion controlhigh limit and circulator control) and nozzle.
Heater opening cover plate.
ARCOLEADER OIL FIRED BOILERS
WATER
Wet base construction. Factory assembled sections. Flush jacket.
boiler number
gross 1=B=R output
Mbh
l=B=R burner capacity
gph
tankless heater number
A l=W=H rating
Boiler less factory installed tan (less hea ter
net l=B=R rating
Mbh
net rating sq ft water
Al-3 Al-4
Al-5 Al-6 Al-7
100 0.95
136 1.30 173 1.65 208 1.95 244 2.30
Boiler with factory installed tankless heater
75.0 102.0
129.8 156.0 183.0
500 680
865 1040 1220
A1-3-T
A1-4-T A1-5-T A1-6-T A1-7T
100 0.95 136 1.30 173 1.65 208 1.95 244 2.30
732 3y, 732 4 Vi 743 5'/2 743 6
743 6
75.0 102.0 129.8 156.0 183.0
500 680 865 1040 1220
Trade Price
$228.00 291.00 359.00 423.00 491.00
$254.00 317.00 404.00 468.00 536.00
chimney size
8x8x15 8x8x 15 8x8x 15 8x8x 15 8 x 12x15
8x8x 15 8x8x 15 8x8x 15 8x8x 15 8 x 12 x15
approx. shipping
weight
583 730 894 992 1138
593 744 919 1022 1168
Gallons of water per minute heated from 40F to 140F with 200F boiler water temperature.
Standard equipment all boilers: (see options page 19)
Heat Lib-O-Rator high temperature steel combustion chamber. ASME Relief Valve. Theraltimeter. Additional standard equipment boilers with tankless heaters: Tankless heater as listed above factory installed in section assembly. Note: Boilers less factory installed tankless heater are shipped less water heater opening cover unless specified on order. '
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2,
HH-2
Page 18
04547
AMERiCAN-<Standard
bo.ler-burner units
HYDRONICHE AT INC
0,1 F,RED BOILERS
________________________________________________________________________________ ______________ _______________________________
WATll
ARCOLEADER OPTIONAL EQUIPMENT
PACKAGED BOILER-BURNER UNITS only:
WAk_\._l _! t, iAtX jUC _J:it t'UI_____ ,>-rl-"- -"- J .JJut*M oUo'An'* Fr. "
* " ---- - .Dc-ip.- - W*itn- T-Men*
extension, shipped in separate carton, provides 15-%" enclosure in front for concealment of
oil burner and controls; approximate shipping weight 35 lbs,
Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra.
Add-on No. 36-Z Arcoflame control set will be furnished when specified on order at $20.35 Trade Price extra. (Add-on zone. Use only with No. 36 control set.)
Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30.
BOILER-BURNER UNITS only:
Arcoflame control sets other than those included in Trade Price of boiler-burner units will be furnished when specified on order at the following charges:
Contra) Sot
With Hoatar
Water control set No. 13
--
Water control set No. 36
--
Water control set No. 36-Z
$20.35
(Add'On zone. Use only with No. 36 control set.)
Lass Halter
* $ 9.10
20.35
* Boiler-burner units less heiter can be ordered for use on gravity systems: Specify No. 13 Arcoflame control set and deduct $5.90 from Trade Price of unit less heater and specify water heater opening cover
plate with 3* tapping.
Detailed description of Arcoflame control sets is shown on page 32.
Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra.
Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30.
BOILER-BURNER UNITS or OIL FIRED BOILERS: Jacket extension; if desired specify on order and add $26.00 to Trade Price of boiler. Jacket
extension provides 1534" enclosure in front for concealment of oil burner and controls. Approximate shipping weight 35 lbs.
Oil fired boiler heater opening cover plate: furnished only when specified on order at no charge. If specified on order cover plate can be tapped 3" for gravity installations.
BUILT-IN HEATERS:
Built-in tankless heaters can be ordered for separate shipment with Boiler-Burner units or Oil Fired Boilers less factory installed tankless heaters at the following Trade Prices:
Hatter number
723 732 743
Trade Price $25.00 27.10 47.70
NOTE: for I--W--H ratings and boilers with which heaters can be used, see table below.
Water mixing valves: for prices, see page 32.
ARCOLEADER l=W=H RATED TANKLESS HEATERS
Heaters tested with boilers.
Built-in tankless heaters for Arcoleader Boiler-Burner units and Oil Boilers can be ordered for separate shipment with units or boilers specified less tankless heaters. See Trade Prices above. Select heater desired from table below.
unit or
boiler size
l=B=R burner capacity
gph
heatar 723
A l=W=H rating
heater 732
heater 743
Al-3 0.95 3 Vi 3 Vi Al-4 1.30 3 Vi 4 Vi Al-5 1.65 3 V* 4 Vi 5'/2 Al-6 1.95 3 Vi 4 Vi 6
Al-7 2.30 3 Vt 4 Vi 6
A Gallons of water per minute heated from 40? to 140? with 200? boiler water temperature.
For discount on repairs, see page 2.
Page 19
MH-2
04548
BOILER-BURNER UNITS OIL FIRED BOILERS
ITIAM AND WATIR
AMERicAN-fStandard
HYDRONIC HEATING
ARCOLINER BOILER-BURNER UNITS
Wet base construction. Flush jacket. Factory assembled sections.
Arranged for but less Built-in Tank or Tankless Type Water Heater
boller-bumer unit number
STEAM
WATER
WIDE BACK TYPE
SO-153-BT S-0 154-B-T S-0 155-B-T S-0-156-B-T
W-0-153-B-T W-O-154-B-T W-O-155-B-T W-0-156-B-T
grot* l=B=R output
Mbh
l=B=R bumtr capacity
gph
net l=B =R rating
ft steam
Mbh
97 1.00 303
72.8
132 1.35 413
99.0
164 1.60 513 123.0
188 1.80 588 141.0
nat rating eq ft water
485 660 820 940
Trada Price with standard equipment
Chlmnay liZI
$353.55 416.55 475.15 518.15
8 x 8 x 20 8 x 8 x 20 8 x 8 x 25 8 x 8 x 25
approx. shipping weight
851 1010 1163 1394
Nozzle sizes, gel. per hour, furnished with Areollner Boiler-Bumer Units ere as follows: No. 153. 0.90-70* H; No. 154. 1.25-60* H; No. 155. 1.50-60* S: No. 156. 1.65-60* S.
Standard equipment: (see options, next page)
Model DH-5 Arcofiame oil burner with sling mounting for front firing. CA-701 primary control. Draft stabilizer. Heat Lib-O-Rator high temperature steel combustion chamber (no deduction for omission). Motors and controls regularly furnished are for 115 volt. 60 cycle current.
Steam only; No. 11 Arcofiame control set (CA-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge, ASME safety valve, gauge glass and trimmings.
Water only: No. 13 Arcofiame control set (CA-520 thermostat, CA-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve.
ARCOLINER OIL FIRED BOILERS
Wet base construction. Flush jacket. Factory assembled sections.
Arranged for but less Built-in Tank or Tankless Type Water Heater
boiler number
STEAM
WATER
WIDE BACK TYPE
groat l=B=R output
Mbh
l=B=R burner capacity
gph
net 1=0 =R rating
sq ft team
Mbh
nt rating aq ft watar
S-0-153-T S-0-154-T S-0-155-T S-0-156-T
W-0-153-T W-0-154-T W-0-155-T W-0-156-T
97 1.00 303
72.8
485
132 1.35 413
99.0
660
164 1.60 513 123.0 820
188 1.80 588 141.0 940
Trade Price with standard equipment
$228.00 291.00 349.00 392.00
Standard equipment: (see options, next page)
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings.
Water Theraltimeter and ASME relief valve.
Chimney size
8 x 8 x 20 8 x 8 x 20 8 x 8 x 25 8 x 8 x 25
approx. shipping
weight
772 930 1083 1234
Jacket extension shown
a For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH2
Page 20
04549
AMERicAN-^Standard
HYDRONIC HE ATI NO
ARCOUNER OPTIONAL EQUIPMENT
BOILER-BURNER UNITS only:
Arcoflame control sets other than those included in Trade Price of Boiler-Burner Units will be furnished when specified on order at the following added charges:
Control sot
Added Chare*
Steam control set No. 12...................................$13.30 Water control set No. 15.................................. 22.75 Water control set No. 16.................................. 24.40 Water control set No. 16-Z................................ 53.20 Water control set No. 26 .................................. 24.40 Water control set No. 33.................................. 5.90
Detailed description of Arcoflame control sets is shown on page 32.
Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra.
BOILER-BURNER UNITS or OIL FIRED BOILERS:
Jacket extension: if desired specify on order and add *27.50 to Trade Price of boiler. Jacket extension provides 20W" en closure in front for concealment of oil burner and controls. Approximate shipping weight 47 lbs.
Water mixing valves: for prices, see page 32.
For low water cut-off for use with steam units, see page 32.
Molded refractory combustion chambers: available for Oil Boilers at Trade Prices below when specified on order.
Cover plate for water heater opening will be furnished if specified on order at added Trade Price charge of $4.00.
Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30.
450-BC-l Vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam units see page 31 for added charge.
The Heat Lib-O-Rator molded refractory type combustion chamber shown below for Arcoliner Boilers may be specified in place of steel chambers regularly furnished at no charge for No. 153-B-T or 154-B-T. Add to Trade Price for boiler No. 155-B-T $2.85 and for No. 156-B-T $5.75.
BUILT-IN HEATERS:
Below are the ratings and Trade Prices covering Built-in tank or tankless heaters available for Arcoliner Units. For detailed information on ratings, see page 2.
Haatar No. 587 589
596
Hiatir T>p* tank tankless
tankless
Haat*r Ratings gals, capacity
85 3 per minute 3`/2 per minute
Trad* Pric* $22.60 29.90
35.00
apprex. shipping
walght 23 25
27
HEAT UB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
bollar numbar
153-T) 154-Tj 155-T 156-T
H*at Ub-O-Rator modal no.
No. 4 No. 5 No. 6
max. firing rata gal. p*r nour
1.35 1.65 2.00
Trad* Pric*
$10.95 13.85 16.75
For discount on repairs, see page 2.
Pig* 21
approx. shipping waigftt
77 86 90
HH-2
04550
wmxBohNrnmwTs
OIU (FIRED IBOILERS
ITU* AHP WMW
AMfemc^N-^tanda^a
H Y, DHO Nl C UtAT I N Q
rpmw
Flush jacket.
boller-bumer
STEAM
WATER
fro**
f*:B=R output
Mbh
- ,, *
UsBsR. bumor capacity
CPh
n*tl=B =R rating
<i steam
Mbh
not rating
water
Trade Price with squlpmsnt
chlmnay
approx. shipping weight
Arranged for but less Built-in Tank or Tankless Type Water Heater
S-84-OB S-85-OB S-86-OB
S-87-OB S-88-OB S-89-OB
>.
W-84-OB W-85-OB W-86-OB
W-87-OB W-88-OB W-89-OB
143 175 202
230 261 288
1.40 1.75 2.00
2.30 2.55 2.80
447 547 631
719 816 900
107.3 131.3 151.5
172.5 195.8 216.1
715 875 1010
1150 1305 1440
$452.15 512.70 557.35
609.85 666.85 713.85
8ot 8 x 20 8 x 8 x 25 8 x 8 x 25
8 x 12 x 30 8 x 12x30 8 x 12 x 35
1338 1479 1603
1746 1863 2007
*Nozzle sizes, gph, 60* S. furnished with Oekmont boiler-burner units: No. 64, 145; No. 65. 1.65; No. 86, 2.00; No. 67. 2.25; No. 88, 2.50; No. 89, 2.75.
Standard equipment: (see options, next page)
Model DH-5 Arcoflame oil burner with sling mounting for rear firing. CA-701 primary control. Draft stabilizer..
Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omis sion listed on page 23.
Motors and controls regularly furnished are for 115 volt, 60 cycle current.
Steam only:
No. 11 Arcoflame control set (CA-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge, ASME safety valve, gauge glass and trimmings.
Water only:
No. 13 Arcoflame control set (CA-520 thermostat, CA-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve.
OAKMONT OIL FIRED BOILERS
Flush jacket.
Arranged for but less Built-in Tank or Tankless Type Water Heater
hollar number
STEAM
WATER
frees l=B=R outgut
l=B=R burner capacity
*Pb
nat l=B =R ratine
*q ft team
Mbh
net ratine sq ft water
Trade Price with standard equipment
S-84 S-85 S-86
S-87 S-88 S-89
W-84 W-85 W-86
W-87 W-88 W-89
143 175 202
230 261 288
1.40 1.75 2.00
2.30 2.55 2.80
447 547 631
719 816 900
107.3 131.3 151.5
172.5 195.8 216.1
715 875 1010
1150 1305 1440
$320.00 379.00 422.00
472.00 529.00 576.00
chlmnay size
8 x 8 x 20 8 x 8 x 25 8 x 8 x 25
8x12x30 8 x 12 x 30 8 x 12 x 35
Standard equipment: (see options, next page)
. Steam:
......
Steam gauge, ASME safety valve, gauge glass and trimmings.
Water Theraltimeter and ASME relief valve.
approx. shipping weight
1109 1245 1352
1485 1602 1746
a For complete information on boiler ratings, see page 2. For discount on repairs,, see page 2.....
HH2
....
Pin 22
...............
04551
Ambrigan-<tandat#
H YD RON I C HEATING
i ' 'W -
-t v
HS:>. v j-c
OAKMONT OPTIONAL EQUIPMENT
BOAerUMI^NIt8t
OIL ? FIRED1. BOILERS
(TUM AMD WATTA
BOILER-BURNER UNITS only]
Arcoflame control sets other than those included in Trade Price of Boiler-Burner Units will be furnished when speci fied on order at the following added charges:
Central Set
Added Charge
Steam control set No. 12.................................... $13.30 Water control set No. 15................................... 22.75 Water control set No. 16................................... 24.40 Water control set No. 16-Z................................. 53.20 Water control set No. 26................................... 24.40 Water control set No. 33................................... 5.90
Detailed description of Arcoflame control sets is shown on page 32.
Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra.
Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30.
450-BC-l vapor limit contra); if desired in place of 450-BA-l pressure limit control regularly furnished for deem units-- see page 31 for added charge.
BOILER-BURNER UNITS or OIL FIRED BOILERS:
Jacket extension; if desired specify on order and add $33.25 to Trade Price of boiler. Jacket extension provides 1544" en closure at rear for concealment of oil burner and controls. Approximate shipping weight 51 lbs.
Water mixing valves: for prices, see page 32.
For low water cut-off for use with steam units, see page 32.
Molded refractory combustion chambers; added Trade Prices to Oil Boiler Trade Prices are same as "Deduct for Omis sion" Prices shown below and will be furnished when speci fied.
Cover plate for water heater opening will be furnished If specified on order at added Trade Price charge of $4.50.
BUILT-IN HEATERS:
Below are the ratings and Trade Prices covering Built-in tank or tankless heaters available for Oakmont units. For detailed information on ratings, see page 2.
Hotter No.
598 599 583
585
597
Motor Typo tank tank tankless
tankless
tankless
Hotor Ratings gals, capacity
40 100 3 per minute 3 V4 per minute 4>/i per minute
Trade Price
$16.00 24.20 38.00
40.50
60.00
approx. shipping weight
23 27 .83
104
92
imtt number
84 85 86 871 88 > 89J
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
Hast Ub-O-Rator model No. included
No. 00 No. 1 No. 2
No. 3
maximum firing rate gallons per hour
1.50 1.75 2.25
3.00
deduct for omission
$17.00 18.55 20.20
22.70
approx. shipping weight
148 153 170
180
For discount on repairs, see page 2.
Pi< 23
04552
H H-2
Awfertft^-^tattdard
OILJ FIRED) SOILKRS
mu amo wAm
rtYDft^lC H^AYlWOf
SEVERN BOILER-BURNER UNITS
Flush jacket
bollar-bumar STEAM 1 WATER
YffaisA lf|*'&itng J A ,Inatiilad radiation 1
_l___ l!_____
S ri 1 taam 1
Uhh
<! ** water
NOT TAPPED FOR BUILT-IN TANK TYPE WATER HEATER (see option*)
S-17-OB
S-21-OB S-25-OB S-29-OB S-33-OB S-37-OB
W-17-OB W-21-OB W-25-OB W-29-OB W-33-OB W-37-OB
146 168 188 216 247 278
1.5 1.7 "1.9 2.2 2.5 2.8
.
456 525 588 675 772 869 .
109.5 126.0 141.0 162.0 185.3 208.6
730 840 940 1080 1235 1390
T TS3e '
standard qufpmant
$471.70 509.70 548.35 589.35 650.85 706.85
ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER
S17-OBT 1 r W17-OB-T
146
1.5
456 109.5
730 $477.70
S-21-OB-T
W-21-OB-T
168
1.7
525 126.0
840
515.70
S-25-OB-T
W-25-OBT
188
1.9
588 141.0
940
554.35
S29-OB-T
W-29-OB-T
216
2.2
675 162.0 1080
595.35
S-33-OB-T
W-33-OB-T
247
2.5
772 185.3 1235
656.85
S-37-OB-T
W-37-OBT
278
2.8
869 208.6 1390
712.85
*Nozzla tizts. gph 60*S, fumithad with Savam boflar-burnar unite No. 17, US; No. 21, 1.50; No. 25. 1.75; No. 29, 2.00; No. 33. 2.25; No. 37. 2.50.
1 1 shipping 1
1303 1458 1570 1710 1815 1975
1312 1461 1579 1719 1824 1984
Standard equipment: (see options, next page)
Model DH-8 Arcoflame oil burner with sling mounting for front firing. CA-701 primary control. Draft stabilizer. Heat Lib-O-Rator refractory combustion Chamber; model number and deduction for omis sion listed on page 25. Motors and controls regularly furnished are for 115 volt, 60 cycle current.
Steam only. No. 11 Arcoflame control set (CA-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge, ASME safety valve, gauge glass and trimmings.
Water only: No. 13 Arcoflame control set (CA-520 thermostat, CA-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve.
SEVERN OIL FIRED BOILERS
Flush jacket.
boJIar-numbar STEAM | WATER
grots output
Mbh
firing ratt
fph
Installed radiation
M| ft ataam
Mbh
NOT TAPPED FOR BUILT-IN T LNK TYPE WATER H EATER (see options)
sq ft watar
S-17-0 S-21-O S-25-O S-29-0
S-33-0 S-37-O
W-17-0 W-21-0 W-25-0 W-29-0 W-33-0 W-37-0
146 1.5 456 109.5 730
168 1.7 525 126.0 840 188 1.9 588 141.0 940 216 2.2 675 162.0 1080 247 2.5 772 185.3 1235 278 2.8 869 208.6 1390
ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER
S-17-OT
S-210T S-25-OT S-29-0-T
S-33-OT S-37-0-T
W-17-O-T W-21-O-T W-25-0-T W-29-O-T W-330-T
W-37-0-T
146 168 188 216 247 278
1.5 456 109.5 730
1.7 525 126.0 840
1.9 588 141.0 940
2.2 675 162.0 1080
2.5 772 185.3 1235
2.8
'869
208.6
1390
Standard equipment: (see options, next page) Steam:
Steam gauge, ASME safety valve, gauge glass and trimmings.
Water
, Theraltimeter and ASME relief valve.
Trada Prlca with standard aqulpmant
$338.00 376.00 413.00 454.00 513.00 569.00
$344.00 382.00 419.00 460.00 519.00 575.00
For complete Information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-2 -- r. -I
----------------------------------------------------
~ Tl|T ...
approx. shipping weight
1075 1230 1325 1465 1560 1720
1084 1239 1334 1474 1569 1729
04553
AMERiGAk-fStandard HYDRO.fi I CL> HEATING
print*
v*
SEVERN OPTIONAL EQUIPMENT
toher-burner^ units
dOIL'FlREDlBOILERS
swam andwatu
BOILER-BURNER UNITS only: .
Arcoflame control acts other than those included in Trade Price of Boiler-Burner Units will be furnished when specified on order at the following added charges:
Control Set
Added Charge
Steam control set No. 12.................................. $13.30 Water control set No. 15................................. 22.75
Water control set No. 16................................. 24.40 Water control set No. 16-Z............................... 53.20 Water control set No. 26 ................................. 24.40 Water control set No. 33................................. 5.90
Detailed description of Arcofiame control sets is shown on page 32.
Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra.
Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30.
450-BC-l vapor limit control: If desired in place of 450-BA.-1 pressure limit control regularly furnished for steam unitssee page 31 for added charge.
BOILER-BURNER UNITS or OIL FIRED BOILERS:
Water mixing valves: for prices, see page 32. For low water cut-off for use with steam units, see page 32.
Molded refractory combustion chamber; added Trade Prices to Oil Boiler Trade Prices are same as "Deduct for Omission" Prices shown below and will be furnished when specified.
Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at an added Trade Price charge of $3.70.
BUILT-IN HEATERS:
If 2%' right or left side tapping in back section for Built-in heater No. 703 is desired, specify on order and add $2.00 to Trade Price of unit or boiler.
Below are the ratings and Trade Prices covering Built-in tank
or tankless heaters available for Severn units. For detailed
information on ratings, see page 2.
- '
Hulir No.
703 594 595 590
Hwtir Typo
Hsater Ratine* gal*, capacity
tank tank tank tankless
66 100 160
3 Vi per minute
Trade . Price
$ 9.00 48.00 42.50 36.00
approx. hipping weight
7 54
51 60
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
unit number
Meet UWWUtoc model No. Included
maximum firing rata gallons per hour
deduct for omission
approx. shipping weight
17. 21 25, 29 33, 37
No. 1 No. 2 No. 3
1.75 2.25 3.00
$18.55 20.20
" r 22.70
153 170 180
For discount on repairs, see page 2.
P* 25
04554
HH-2
imMttMNttc? nccatcno:
.yW>li:ER:BURNER UNITS
-a . . >........
Msenttnumber ...
` ------ 'STEAM
WATER
Flush Jacket
imw.rtnw
witfr worldpj pressure.
------- 1-------
grow l=B=R output
Mol)
IsSsR burntr capacity
___ rp* _
net 1=1 =R rating
*twm
Mbh
not ratine soft watar
Trada Prica wHh Undard qulpmont
For Built-In Water Heater Arrangement, see page 27
chlmnoy Iza
approx. thlMinc watgfrt
iivA-504-SB' 1 . . A-505-SB
. A-506-SB
A-507-SB A-508-SB A-509-SB
A-510-SB . A-511-SB
^A-504-WB A-505-WB
-.A-506-WB
A-507-WB A-508-WB A-509-WB
A-510-WB A-511-WB
261 346 426
508 588 668
748 830
2.55 3.30 4.00
4.75 5.55 6.30
7.00 7.65
816 1082 1332
1588 1838 2088
2338 2594
195.8 259.6 319.6
381.1 441.1 501.1
561.1 622.7
1305 1731 2131
2541 2941 3341
3741 4151
$ 692.05 827.90 924.55
1029.55 1115.55 1213.60
1411.60 1505.60
8 x 12* 15 8 x 12 x 20 12 x 12 x 20
12 x 12 x 20 12 x 16 x 25 12 x 16x25
12 x 16 x 25 16x16x30
1702 1969 2286
2563 2807 3107
3382 3684
Nozil. tizmt. fph, furnished with A-S units art as follows: No. A-504, 1 2.50 60'S; A-505. 2 1.65 70'S; A-506 2 2.00 70'S: A-507 1 2.25 & 1 2.50 BO'S; A-508 2 2.75 80*S; A-509. 1 3.00 A 1 3.25 BO'S: A-510 2 3.50 BO'S; A-511 1 3.50 A 1 4.00 BO'S.
Standard equipment: (sea options, noxt page)
OH-5 sling mounted oil burner for A-504, with 1-stage fuel unit.
45W-3606 oil burner for A-505, A-506;
62A-7056 oil burner for A-507, A-508, A-509; 45W-3606 and 62A-7056, flange mounted, with 2-stage fuel unit.
The above burners are furnished with CA-701 primary controL
96-7506 oil burner for A-510, A-511; flange mounted, with 2-stage fuel unit; electronic Same safeguard control consisting of C7013A photocell installed in burner; Q270A safety switch base mounted on burner housing; RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly.
Draft stabilizer.
Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omission listed on page 27.
Motors and controls regularly furnished are for 115 volt, 60 cycle current.
Steam only; No. 11 Arcoflame control set (CA-520 thermostat, 450-BA-l pressure limit control) and nozzle (s).
Steam gauge, ASMS safety valve, gauge glass and trimmings.
Water only; No. 13 Arcoflame control set (CA-520 thermostat, CA-655 immersion limit control) and nozzle (s).
Theraltimeter and ASME relief valve for 50 lbs.
A-5 OIL FIRED BOILERS
Flush jacket. Tested and equipped for 50 lbs. water working pressure.
boilar numbar
STEAM
WATER
frow IsBsR output
Mbh
l=S=R bumar capacity
*ph
nat l=B sR ratine
*q ft staam
Mbh
nat rating tq ft watar
Trada Prica
For Built-in Water Heater Arrangement, see page 27.
A-504-S A-505-S A-506-S
A-507-S A-508-S A-509-S
A-510-S A-511-S
A-504-W A-505-W A-506-W
A-507-W A-508-W A-509-W
A-510-W A-511-W
261 346 426
508 588 668
748 830
2.55 3.30 4.00
4.75 5.55 6.30
7.00 7.65
816 1082 1332
1588 1838 2088
2338 2594
195.8 259.6 319.6
381.1 441.1 501.1
561.1 622.7
1305 1731 2131
2541 2941 3341
3741 4151
$ 553.00 645.00 733.00
822.00 908.00 996.00
1084.00 1178.00
Standard equipment: (see options, next page)
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings.
Water Theraltimeter and ASME relief valve for 50 lbs.______________
a For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-2
Paga 25
chimnay tin
8x 12 x 15 8 x 12 x 20 12 x 12x20 12 x 12 x 20 12 x 16x25 12 x 16x25 12 x 16x25 16 x 16x30
approx. ahlppine walgttt
1489 1750 2050 2306 2550 2825 3075 3377
04555
I I:
t'-r<
AMferac^-i$tandat7i
H Y D R.0JU CD HC Ajr INO
AOILER-SURNER^UNITS iOIt! fIRED' BOILERS
miAM^NB WATn
A-5 OPTIONAL EQUIPMENT ,
BOILER-BURNER UNITS enlyi
Arcoflame control ceta other than those included in Trade Price of boiler-burner units will be furnished when specified
on order at the following added charges:
Control Sot
Added Charge
Steam control set No. 12 .........
. $13.30
" Water control set No. 15..........
22.75
Water control set No. 33 ................
5.90
Water control set No. 36 . %z.. . 15.05
- Water control set No. 36-Z ..
0.35
(Add-on tone. Uea only with No. 36 control eat)
Detailed description of Arcoflame control sets is shown on page 32.
Electronic flame safeguard equipment:
62A-70S6F burner with electronic flame safeguard control la available instead of 62A-70S6 burner for A-507, A-508 and A-S09. boiler-bumer units at added Trade Price charge of $93.00. The electronic control con* slats of C7013A photocell Installed In burner. Q270A safety switch base mounted on burner housing. RA890E safety switch packed with burner; delayed oil valve Installed between fuel unit and drawer assembly.
For InstallaUona requiring Factory Mutual Approval and In states and municipalities with regulations more stringent than Underwriters' Lab oratories. Inc., oil burners are available with special electronic flame safeguard controls for A-5 boiler-bumer units as follows:
62-A-7056 FFM burner for A-507. A-508 and A'509 boiler-bumer units, at added Trade Price charge of $133.00.
96-7507 burner for A-510 and A-511 boiler-bumer units at added Trade Price charge of $30.00.
Motors and controls regularly furnished are for 1 IS volt 60 cycle.
450-BC-l vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam unitssee page 31 for added charge.
Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30.
Two-stage fuel unit for DH-5 Arcoflame o11 burner will be furnished when specified on order at $5.00 Trade Price extra.
BOILER-BURNER UNITS or OIL FIRED BOILERS:
Jacket extension; if desired specify on order and add $33.85 to Trade Price of boiler. Jacket extension provides 25" en closure in front for concealment of oil burner and controls. Approximate shipping weight 57 lbs.
Water mixing valves: for prices, see page 32.
For low water cut-off for use with steam units, see page 32.
.Molded refractory combustion chembert`for A-5 boilers: Trade Prices are same as "Deduct for Omissi6n"Prices shown below. c-
If desired, provision for tankless heaters is available at no additional charge. When suffix letter "T" is added on order to unit or boiler numbers, the following number of openings in center sections will be furnished.
Unit No.
Openings
A-504-T
2
A-505-T thru A-508-T
3
i- A-509-T thru A-511-T
4
Not*-. Additional openings can be specified on order.
Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $335 each.
NO. 530 TANKLESS HEATER:
No. 530 tankless heater available .in single or quantity lot price at $30.65 Trade Price each. _
The following table shows the recommended number of heat ers to be used with each boiler and the ratings/attained if more than one heater is connected in. parallel:
boiler no. .
All Sizes All Sizes A-505--A-511 A-508--A-51X A-510--A-511
nbbofhoatora
1 -: 2 3 4 5
radng-gpm
4 7 10 .13 16
Note: Additional hatters can b added if Ihe heater* are aarving differ ent system* and It Is not likely that heaters will all be In use at the same time.
-Gallona of water per minute raised from 40 F to 140 F with 200 F boiler water temperature.
Copper pipe manifolds factory assembled for multiple heater parallel hookup shipped in boxes of two manifold assemblies per box when specified with heaters are available at the fol lowing charges:
Manifold assembly
2 heater 3 heater 4 heater
Trade Price per Bex
$4.80 6.80 8.80
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
unit
number
A-504 A-505 A-506, A-507. A-508 A-509, A-510, A-511
Hoot Ub-O-FUtor
modJ No. Included
14-A 16-A 16-A 17-A
'"
maximum firing rata
gallon* par hour
2.55 3.30 5.55 7.65
deduct for omlwion
$23.90 23.90 32.55 37.60
______ 'i1 __________
approx. shipping weight
158 163 180 200
For discount on repairs, see page 2.
7
Paga 27
04556
HH-2
BOILER"BURNER UNITS
OIL' FIRED! BOILERS
ITUa AMO WATt*
American-vStandard
HYDBONIC HE ATI NO
A-7 BOILER-BURNER UNITS
Jacketed and unjacketed. Tested and equipped for 90 lbs. water working pressure.
boder-bumer unit number
STEAM
WATER
` 4'
frow teBsR
l=BsR burner
output capacity
Mbh
CPh
irwtlr l=R ratine
Hft ataam
Mbh
nat ratine sq ft water
chimnay size
unjacketed
l.ckated
Trada Plica approx. Trada Price approx. with atandird shipping with etanderd ahipplnc
equipment weight equipment weight
A-705-S0-B A-.706-SO-B A-707-S0-B
A-708-SO-B A-709-SO-B A-710-SO-B
A-711-SO-B A-712-SO-B
A-705-WO-B A-706-WO-B A-707-WO-B
A-708-WO-B A-709-WO-B A-710-W0-B
A-711-WO-B A-712-WO-B
865 1012 1196
1376 1570 1760
1956 2148
8.15 9.55 11.25
12.90 14.65 16.30
18.00 19.65
27073163 3738
4340 5013 5672
6328 6949
649.7 759.2 897.2
1041,6 1203.1 1361.2
1518.6 1667.7
4331 5061 5981
6944 8020 9075
10125 11118
16 x 16x28 16 x 16 x 30 16 x 20 x 36
16 x 20 x 42 16 x 20 x 45 20 x 20 x 50
20 x 20 x 55 20 x 20 x 60
$1571.00 1685.00 1852.00
2191.00 2336.00 2505.00
2694.00 2856.00
4231 4883 5532
6283 6919 7603
8195 8871
$1652.00 1771.00 1950.00
2307.00 2474.00 2651.00
2850.00 3023.00
4403 5058 5715
6492 7134 7822
8456 9169
"Nozzle sizes, gph. 80*S, furnished with A-7 units ere es follows: A-705. 2 4.00: A-706, 1 4.S0, 1 5.00; A-707, 2 5.50; A-708 1 4.00. 2 4.50; A-709. 1 4.50. 2 5.00; A-710. 1 5.00. 2 5.50; A-7U. 3 6.00; A-712. 3 6.50.
Standard equipment: (see options, next page)
96- 7508 oU burner for A-705. A-706, A-707.
97- 7606 oil burner for A-708, A-709. A-710.
98- 7706 oil burner for A-711, A-712.
All with pedestal mounting; two-stage fuel unit; electronic flame safeguard control consisting of C7013A photocell installed in burner. On model 96-7508 burner, Q270A safety switch base is mounted on burner housing. On models 97-7606 and 98-7706, W415B1 panel is furnished with Q270A safety switch base and R488E load relay. On all three models, RA890E safety switch is packed with burner; delayed oil valve in stalled between fuel unit and drawer assembly.
Draft stabilizer.
Steel pedestal base in addition to regular 12' base; 8' height for 5 through 7 section; 10' height for 8 through 12 section.
Steam only: No. 11 Arcoflame control set (CA-520 thermostat, 450-BA-l pressure limit control) and nozzles.
Steam gauge, ASME safety valve, gauge glass and trimmings.
Water only:
No. 13 Arcoflame control set (CA-520 thermostat, CA-655 immersion limit control) and nozzles.
Theraltimeter and ASME relief valve for 50 lbs.
Combustion chamber not furnished. See Installation-Operation and Maintenance Man ual for combustion chambers for A-7 boiler-burner units.
A-7 OIL FIRED BOILERS
Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure.
boiler number
STEAM
WATER
A-705-SO A-706-SO A-707-SO
A-708-SO A-709-SO A-710SO
A-711-SO A-712-S0
A-705-WO A-706-WO A-707-WO
A-708-WO A-709-W0 A-710-WO
A-711-WO A-712-WO
croaa IsBsR
I=B=R burner
output capacity
Mbh
SPh
net Is B=R rating
sq ft ataam
Mbh
nat rating aq ft water
866 1012 1196
1376 1570 1760
1956 2148
8.15 9.55 11.25
12.90 14.65 16.30
18.00 19.65
2707 3163 3738
4340 5013 5672
6328 6949
649.7 759.2 897.2
1041.6 1203.1 1361.2
1518.6 1667.7
4331 5061 5981
6944 8020 9075
10125 11118
chimney aixe
unjacketed
lacketed
approx.
approx.
Trade Price shipping Trad. Price shipping
weight
weight
16 x 16x28 16 x 16x30 16 x 20 x 36
16 x 20 x 42 16x20x45 20 x 20 x 50
20 x 20 x 55 20 x 20 x 60
$1200.00 1314.00 1481.00
1643.00 1788.00 1957.00
2121.00 2283.00
3882 4518 5149
5720 6330 6990
7556 8208
$1281.00 1400.00 1579.00
1759.00 1926.00 2103.00
2277.00 2450.00
4054 4693 5332
5929 6545 7209
7817 8506
Standard equipment: (see options, next page) Steam: Steam gauge, ASME safety valve, gauge glass and trimmings.
Water: Theraltimeter and ASME relief valve for 50 lbs.
Tor complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-2
pa28
04557
AMERiCAN-<$taitdard
HYDRONICHE AT INO
A-7 OPTIONAL EQUIPMENT
BOILER-BURNER UNITS OIL FIRED BOILERS
1T1AM AND WATIl
BGiLtK-bURNER UNITS only:
Arcoflame control sets other than those Included in Trade Price of boiler-burner units will be furnished when specified on order at the following added charges:
Control Set
Added Charge
Steam control set No. 12....................................................................... $13.30 Water control set No. 15...................................................................... 22.75 Water control set No. 16...................................................................... 24.40 Water control set No. 16-Z.................................................................. 53.20 Water control set No. 26 ...................................................................... 24.40 Water control set No. 33...................................................................... 5.90
Detailed description of Arcoflame control sets is shown on page 32.
Electronic flame safeguard equipment: For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Laboratories, Inc., oil burners are available with special electronic flame safeguard controls for A-7 boiler-burner units as follows:
96- 7509 oil burner for A-705, A-706 and A-707 boiler-burner units at added Trade Price charge of $30.00.
97- 7607 oil burner for A-708, A-709 and A-710 boiler-burner units, and 98-7707 for A-711 and A-712 boiler-burner units at added Trade Price charge of $13.50.
450-BC-l vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam units-see page 31 for added charge.
Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30.
BOILER-BURNER UNITS or OIL FIRED BOILERS:
Water mixing valves: for prices see page 32.
McDonnell-Miller No. 47-2 and No. 51-2 low water cut-off and feeder combinations: No. 47-2 used with A-705 through A-707 and No. 51-2 used with balance of sizes. Special equalizer tap ping for bottom connection of No. 51-2 located 6 inches below water line on front section. Specify No. 47-2 or No. 51-2 on order and add to Trade Price of steam boilers with standard equipment Trade Price for these items shown in the current McDonnell-Miller price sheet.
For No. 369 low water cut-off for use with steam units, see page 32.
OIL FIRED BOILERS only:
Steel pedestal bases for installation under the regularly furnished 12" base for greater base heights will be furnished when specified on order at the following added charges:
taction tin 5 through 7 8 through 12
bait height 8"
10"
added charge $44.00 72.00
Page 29
04558
HH-2
OIL BURNERS ZONE CONTROL SETS
American-^Standard
HYDRONIC HEATING
OIL BURNERS for 115 volt, 60 cycle current
For Arcoleoder, Arcoliner, Oakmont, Severn, A-5 and A-7 boilerburner unite
Model 96-7508
model number
capacity gal.
par hour
air tuba length dlam.
mounting
including CA-701 primary control
DH-5
,65- 3.00
5
4
sling
DH-6
.65- 3.00
6
4
sling
45W-3606 3.00- 4.00
7y. 4V flange
62A-7056
4.00- 7.00 10V4 6Vs flange
62A-7056 4.00- 7.00 10V6 6VL flange
Including electronic flame safeguard control
96-7506
6.00-12.00 10*/8 6V6
96-7508
6.00-12.00 10V6 6%
97-7606
10.00-17.00 10`/ 7
98-7706
14.00-20.00 ioy 8
flange pedestal pedestal pedestal
Trado Prico
approx. hipping
weight
$115.15 115.15 159.00 175.00 180.00
55 55 56 77 82
290.00 327.00 476.00 501.00
107 145 208 208
62A-7056 burner supplied with 9" draft stabilizer for A-507 and A-508, and with 12' draft stabilizer for A-509 boilerburner units.
DH-5 burner for Arcoleader, Arcoliner and Oakmont boilerburner units is shipped with pressure ring only. CA-701 pri mary control is shipped installed with Arcoleader Packaged units and is a separate shipping component with Arcoleader, Arcoliner and Oakmont boiler-burner units.
DH-5 burner for A-504 boiler-burner unit is shipped with CA-701 primary control and mounting accessories.
DH-6 burner for Severn boiler-burner units is shipped with CA-701 primary control. Accessories for Severn are shipped in a separate box.
45W-3606 and 62A-7056 burners for A-505 through A-509 boiler-burner units are shipped with CA-701 primary control and mounting accessories.
96-7506 burner for A-510 and A-511, and 96-7508 burner for A-705 through A-707 boiler-burner units are shipped with electronic flame safeguard control consisting of C7013A photo cell installed in burner. Q270A safety switch base mounted on burner housing, RA890E safety switch packed with burner.
For optional control sets and added charges, see page 32.
OPTIONAL ELECTRONIC FLAME SAFEGUARD CON TROL EQUIPMENT:
62A-7056F burner with electronic flame safeguard control is available instead of 62A-7056 burner for A-507, A-508 and A-509 boiler-burner units at added Trade Price charge of $93.00. The electronic control consists of C7013A photocell in stalled in burner, Q270A safety switch base mounted on burner housing. RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly.
For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Laboratories, Inc., oil burners are avail able with special electronic flame safeguard controls for boiler-burner units as follows:
62A-7056FFM burner for A-507, A-508 and A-509 boilerburner units at added Trade Price charge of $133.00.
96-7507 burner for A-510 and A-511 boiler-burner units. 96-7509 burner for A-705, A-706 and A-707 boiler-burner units at added Trade Price charge of $30.00.
97-7607 burner for A-708, A-709 and A-710 boiler-burner units, 98-7707 burner for A-711 and A-712 boiler-burner units, at added Trade Price charge of $13.50.
97-7606 and 98-7706 burners for A-708 through A-712 boilerbumer units are shipped with electronic flame safeguard con trol consisting of C7013A photocell installed in burner. W415B1 panel furnished with Q270A safety switch base and R488E load relay; RA890E safety switch packed with burner.
The above prices are for oil burners with primary control as shown. No. 11 steam or No. 13 water basic control set with CA-520 thermostat, and nozzle (s).
Two-stage fuel unit is available for DH oil burners at $5.00 Trade Price extra.
Two-Stage fuel unit is regularly furnished with 45W, 62A, 96, 97 and 98 oil burners.
Delayed oil valve is standard on all the above burners with electronic controls. V4001A valve installed is available on 45W and 62A burners at $13.00 Trade Price extra.
ZONE CONTROL SETS: Using Hydronic Zone Valves
Two-zone and three-zone control sets utilize one CA-520 thermostat furnished with Packaged G-2 Gas Boilers and Arcoleader Packaged boiler-burner units. When these sets are to be used with
other forced hot water installations using circulator, it will be necessary to secure an additional CA-520 thermostat to control the first zone
Sat No. 2-Z For Two Ion--
Sat No. 3`Z For Three Zones
Set No. 4-Z For Each Zone in Addition to Three Zones
Contents of Sat No. 2*2: 1 CA-520 Round Thermostat
2 V8031B *4" sweat M-H Zone Valves
1 40VA Transformer
Contents of Set No- 3-Z: 2 CA-520 Round Thermostats 3 V8031B *4" sweat M-H ^one Valves 1 40VA Transformer
Contents of Add-on Set No. 4-Z:
l CA-520 Round Thermostat 1 V8031B sweat M-H Zone Valve 1 40VA Transformer
Trade Price
545.19
Trede Price
$70.67
Trade Price
$27.45
HH-2
Pago 30
04559
American-cStandard\
H YDRONIC HE AT IN Oh
OIL BURNERS for ITS volt60 cycle current For conversion and replacement
model number
capacity gal.
per hour
air tuba
length
diam.
mounting (specify If pedestal or flange Is wanted for DH and S2A burners.)
including CA-701 primary control
DH-8 DH-15 DH-23
.65-3.00 .65-3.00 .65-3.00
8 15 23
52A 62-1-7000
3.00-4.00 4.00-7.00
73/i or 10% 16%
4 pedestal 4 4 ' or '
4% flange 6 % pedestal
NOTE: Optional air tube length* are available for 52A burner. Add to Trade Price for
Trade Price
with control
set
with primary control and
nozzle!*) only
approx, ship, volgfati
Wttfl control
set
with primary control and nozzle(t) only
$115.15 117.15 118.15
155.00 170.00
$100.50 102.50 103.50
139.00 154.00
60 65 65
65 73
length $3.50: for 22*/" length $5.50.
55 60 60
60 66
including electronic flame safeguard control
62-2-7002 96-7501 97-7601 98-7701
5.00- 8.00 6.00-12.00 10.00-17.00 14.00-20.00
16% 16% 16% 16%
6%
pedestal
275.00
259.00
83
80
6%
pedestal
290.00
274.00
91
88
7
pedestal
476.00
460.00
168
165
8
pedestal
501.00
485.00
168
165
The above prices for burners with control set include primary control as shown; No. 11 steam. No. 13 or No. 14 water, or No. 19 warm air control set with CA-520 thermostat, as speci fied on order.
For optional control sets and added charges, see page 32.
For burners shown above with primary control and nozzle(s) only, additional controls are available at Trade Prices shown on page 32.
DH-8, DH-15. DH-23, 52A and 62-1-7000 burners are furnished with CA-701 intermittent ignition primary control.
On models with electronic flame safeguard controls, C7013A photocell is installed on burner. On 62-2-7002 and 96-7501, Q270A safety switch base is mounted on burner housing. On 97-7601 and 98-7701, W415B1 panel is furnished with Q270A safety switch base and R488E load relay. On these models, RA890E safety switch is packed with burner; delayed oil valve is installed between fuel unit and drawer assembly.
P52A-4322F burner is available with electronic flame safe guard control consisting of C7013A photocell installed in burner, Q270A safety switch base mounted on burner housing and RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly at $93.00 addition to Trade Price of 52A burner.
OPTIONAL ELECTRONIC FLAME SAFEGUARD CON
TROL EQUIPMENT
For installations with firing rates above 4.00 gph requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Labora tories, Inc., oil burners are available with special electronic flame safeguard controls as follows:
62-2-7003 burner at $30.00 addition to Trade Price of model 62-2-7002.
96-7502 burner at $30.00 addition to Trade Price of model 96-7501.
97-7602 or 98-7702 burner at $13.50 addition to Trade Price of models 97-7601 and 98-7701.
Two-stage fuel unit is available for DH oil burner at $5.00 Trade Price extra.
Two-stage fuel unit is standard on 52A, 62, 96, 97 and 98 oil burners.
Delayed oil valve is standard on all the above burners with electronic controls. V4001A oil valve installed on 52A and 62-1-7000 burners is available at $13.00 Trade Price extra.
When ordering oil burners be sure to specify nozzle sizes wanted. One nozzle is furnished with DH, two nozzles with 52A, 62, 96 and 97, and throe nozzles with 98 oil burners.
Nozzles and strainers are as follows;
For DH: Hollow cone, 60* or 70*, 0.65-1.25 gph.
Solid cone, 60* or 70*. 1.35-3.00 gph.
For 52A, 62, 96, 97 and 98: Solid cone, 70', 1.50-2.00 gph;
80', 2.25-6.50 gph.
Vapor Installations: Substitute 450-BC-l vapor limit control for 450-BA-l pressure limit control with No. 11 or No. 12 con trol sets and add $10.99 to Trade Price.
Electric Clock Thermostat: Substitute T852A for CA-520 ther mostat; specify on order control set number with suffix "B". and add $27.17 to Trade Price.
Substitute C8-580 for CA-520 thermostat: Deduct $2.83 from Trade Price with control set shown above.
Perfxray Primary Controls
Models DH-8, DH-15 and DH-23 conversion and replacement Arcoflame oil burners are available with Perfxray primary control set consisting of CT-99 flame detector factory mounted in air tube, and R-96 programming relay (for jacket mounting only) shipped with burner. Trade prices for burners with constant ignition are the same as shown above either with control set or with primary control and nozzle. If intermittent ignition is wanted specify on order and add $2.00 to the above Trade Prices.
Arcoflame oil burners are approved by the National Board of Fire Underwriters and comply with Commercial Standard CS-75,
Capacities of Arcoflame oil burners are for installations at
sea level and at elevations up to 1,000 feet. Reduce by 4% for each additional 1,000 feet above sea level.
For discount on repairs, see pape 2.
Page 31
04560
H H-2
OIL BURNER CONTROL SETS
AMERICAN-^tandatd
CONTROLS
HYDRONIC HEATING
control Mt
for:
contents of Arcoflame control sat
number
description
add to Trade Price of oil
burner with basic
control ast
No. n Steam No. 12 Stnm
No. 13 Water No. 14 Water No. IS Water
No. 16 Water
No. 16-Z Water
No. 19 Warm Air
No. 20 Warm Air
No. 26 Water
No. 33 Water No. 36 Water
No. 36-Z Water
Boiler without domestic hot water.
Boiler with year-round domestic hot water, built-in heater.
Boiler without domestic hot water, im mersion control.
Boiler without domestic hot water, clamp-on control.
Boiler with year-round domestic hot water, storage tank heater, using cir culator.
Boiler with year-round domestic hot water, built-in tankless heater, using circulator.
2-Zone control, for boiler with yearround domestic hot water, built-in tankless heater, using circulators. Note: For each additional zone, add 1 CA-520 thermostat and 1 CA-262 relay transformer at current prices.
Gravity furnace.
Forced warm air unit.
Boiler with year-round domestic hot water, built-in tankless heater, using circulator.
Boiler without domestic hot water, constant circulator operation.
Arcoleadar and A-5 units ONLY with year-round domestic hot water, builtin tankless heater, using circulator.
Arcoleadar and A-5 unite ONLY. (1 No. 36-Z set is required for each zone in addition to the hrst zone which is controlled by the No. 36 control set.)
CA-520 450-8A-1
CA-520 450-BA-l CA-666
CA-520 CA-655
CA-520 251-MJ
CA-520 CA-655 CA-666 CA-262
CA-520 CA-655 CA-666-DT CA-262
2 CA-520 CA-655 CA-666 CA-666-R 2 CA-262
CA-520 CA-644
CA-520 CA-640-S
CA-520 CA-655 CA-666-AD
CA-262
CA-520 CB-614
CA-520 CA-610
CA-520 CA-260
thermostat limit control
thermostat
limit control 1mm. operating control
513.30
thermostat limit control
thermostat limit control
thermostat
limit control imm. operating control relay transformer
522.75
thermostat limit control imm. control double throw switct
relay transformer
524.40
thermostats limit control
imm. operating control rev. acting low limit control
relay transformers
553.20
thermostat limit control
thermostat fan and limit control
$ 1.35
thermostat Limit control imm. control double throw switch, adj. differential relay transformer
524.40
thermostat high limit rev. act. control
5 5.90
thermostat imm. control relay combination
515-05
thermostat zone control relay
Add-on zone
(Use only with
No. 36 set) 520.35
Controls - Regularly furnished are for 115 volt 60 cycle current
number
description
Trade Price
number
description
Trade Price
CA-520 C8-580 CA-440
AMERICAN-STANDARD
thermostat. ROUND, low voltage thermostat, low voltage thermostat, line voltage
$ 7.74 4.91
13.50
251-MJ CA-260 CA-262
clamp-on water limit control zone control relay relay transformer
8.03 12.60 12.60
450-BA-l 4 50-BC1 CA-6JO
pressure limit control. 0-10 lbs. vapor limit control, 0-3*,fe lbs. immersion control relay combination
11.59 22.58 23.48
CB-614 CA-655 CA-666
high limit reverse acting control immersion limit control immersion operating control
14.36 8.44
10.13
CA-666R CA-666 0T
reverse acting low limit control imm. hot water control, double throw switch
10.13 11.81
CA-666-AD
CA-701 CA-704
AMERICAN-STANDARO
imm. hot water control double throw switch. adjustable differential primary control, intermittent ignition primary control, constant ignition
511.81 27.30 25.80
CA-840-S CA-844 RS-116-F CB-520100
fan and limit control warm air limit control immersion control relay combination mounting cover plate
9.77 8.36 24.90
.45
T-80A
GENERAL CONTROLS thermostat for self-energizing application
5.21
T86A T832A T852A
thermostat, low voltage thermostat, low voltage, manual turn-down thermostat, electric clock
7.80 20.96 34.91
Vernatherm water mixing valves
number
description
size
Trade Price
number
description
size Trade Price
VD-203 VD-205
adjustable non-adjustable
/i%>/j/.-
511.48 12.06 7.92 8.32
VD-206
VD-208 -
adjustable non-adjustable
Va* nom. sweat
x/i0 nom. sweat
5 7.35 6.68
No. 369 McDonnell a Miller low water cut-off for automatically fired steam Arcoliner. Oaicmont, Severn. Exbrook. A-5 and A-7 boilers and/
or boiler-burner units.......................................................................................................
..................................................................... Trade Price each $16.75
HH-2
Page 32
04561
American-Standard
HYDRONIC HEATING
STOKER FIRED BOILERS
JTIAM AMO WATI*
SEVERN STOKER FIRED BOILERS
Flush jacket.
boHr number
grot*
CTF4U
WATFR
output Uhh
________________ J _________
firing rate pound* per iiuui
net Jnetafied rating
*?.* 1 Mbh 1- ____ 1_______________
q ft w.Uf
Not adapted for Built-in Water Heater ( see options below)
Trade Price
appro*. shipping
weight
SC17
SC-21 SC-25
SC-29 SC-33 SC-37
WC-17
WC-21 WC-25 WC-29 WC-33 WC-37
146 16 456 109.5
730 $338.00
1053
168 18 525 126.0
840
376.00
1220
188 21 588 141.0 940 413.00 1301
216 24 675
162.0
1080
454.00
1457
247
27
772
185.3
1235
513.00
1534
278
31
869
208.6
1390
569.00
1687
Standard Equipment:
Steam: Steam gauge. ASME safety valye. gauge glass and trimmings.
Water: Theraltimeter and ASME relief valve.
Optional equipment:
Boilers arranged for but less Built-in heaters: If desired, for use with heaters No 590. 594 and 595, add suffix letter "T" to boiler number and add $6.00 to Trade Price of boiler with standard equipment. If 2V4" right or left side tapping in back section for Built-in heater No. 703 is desired, specify on order and add $2.00 to Trade Price of boiler.
Water mixing valves: for prices, see page 32. For low water cut-off for use with steam Severn boilers, see page 32.
Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at an added Trade Price charge of $3.70. Below are the ratings and Trade Prices tor Built-in heaters available for Severn stoker boilers. For detailed information on ratings, see page 2.
Heater No.
703 594 595 590
Heater Type
tank tank tank tankless
Heater Rating* gals, capacity
66 100 160 3>/2 per minute
Trade Price
$ 9.00 48.00 42.50 36.00
approx. shipping weight
7 54 51 60
EXBROOK STOKER FIRED BOILERS
boiler number
STEAM
WATER
gross_
output Mbh
l=Bs R burner
capacity Ibs/hr
net l=B =R rating
sq ft steam
Mbh
B net
sq ft water
Trade Price
size
Not adapted for Built-in Water Heater (see options below)
SC-207
SC-208 SC-209 SC-2010 SC-2011 SC-2012 SC-2013
WC-207 WC-208 WC-209 WC-2010 WC-201I WC-2012 WC-2013
276
30
863
207.1
1380
$575.00
8x12x25
335 37 1047 251.3 1675
651.00
8x12x25
396
43
1238
297.1
1980
731.00
12x12x30
452 50 1413 339.1 2261
803.00
12x12x30
508 56 1588 381.1 2541
873.00
12x12x35
564 62 1763 423.1 2821
947.00
12x16x40
620
68
1938
465.1
3101
1013.00
12x16x40
Standard Equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings.
Water: Theraltimeter and ASME relief valve.
approx. shipping
weight
2150 2313 2628 2821 3134 3309 3641
Optional equipment:
Boilers arranged for but less Built-in heater: If desired add suffix letter "T" to boiler and add $6.00 to Trade Price of boiler with standard equipment.
Built-in water heaters are available for use with Exbrook "T" type boilers only. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $4 25.
For low water cut-off for Exbrook steam boilers, see page 32.
Below are the ratings and Trade Prices for Built-in heaters available for Exbrook "T" type Stoker boilers For detailed information on ratings, see page 2.
Heater No.
591 592
Heater Type
tank tank
Heater Ratings gals, capacity
120 200
Trade Price
$32.50 46.50
approx. shipping weight
35 53
For complete information on boiler ratings, see page 2
For discount on repairs, see page 2.
Page 33
HH-2
04562
STOKER FIRED BOILERS
fUMi AMD WATft
A/MiBicAN-^taitdaifd HYDRONIC HEATING
boiler number
STEAM
WATER
3SC-8 3-SC-9
3-WC-8 3-WC-9
grots output
Mbh
706 798
NO. 3 REDFLASH STOKER FIRED BOILERS
Jacketed and unjacketed.
firing rats pounds per hour
78 88
9 nst Installed rating
sq ft steam
Mbh
sqft water
2207 2494
529.6 598.6
3531 3991
unjackstad
Trade Price
approx. shipping weight
$1076.00 1195.00
3652 4041
Jacketed
Trade Price
approx. shipping
weight
$1164.00 1286.00
3827 4224
Standard equipment:
Steam: Steam gauge, ASMS safety valve, gauge glass and trimmings.
Water Theraltimeter and ASMS relief valve.
Optional equipment:
External water heater tappings available at following added charges: Jacket-$2.00 per tapping. Sections-|2.00 per tapping.
A-7 STOKER FIRED BOILERS
Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure.
boiler number
STEAM
WATER
gross l=B=R output
Mbh
1=B=R bumsr capacity Ibs/hr
nat l=B =R rating
sq ft staam
Mbh
nat rating sq ft watsr
chimney size
unjsckstsd
Trade Price
approx. shipping
weight
Jacketed
Trade Price
approx. shipping weight
A-705-SC A-705-WC A-706-SC A-706-WC A-707-SC A-707WC A-708-SC A-708-WC
866 1012 1196 1376
95 2707
649.7
111 3163
759.2
131 3738
897.2
151 4340 1041.6
4331 5061 5981 6944
16 x 16x28 16 x 16 x 30 16 x 20 x 36 16 x 20 x 42
$1200.00 1314.00 1481.00 1643.00
3882 4518 5149 5720
$1281.00 1400.00 1579.00 1759.00
4054 4693 5332 5929
A-709-SC A-710-SC A-711-SC A-712-SC
A-709-WC A-710WC A-711-WC A-712-WC
1570 1760 1956 2148
172 5013 1203.1
8020 16 x 20 x 45 1788.00 6330 1926.00 6545
194 5672 1361.2
9075 20 x 20 x 50 1957.00 6990 2103.00 7209
215 6328 1518.6 10125 20 x 20 x 55 2121.00 7556 2277.00 7817
236 6949 1667.7 11118 20 x 20 x 60 2283.00 8208 2450.00 8506
Standard Equipment: Steam:
Steam gauge, ASME safety valve, gauge glass and trimmings.
Water Theraltimeter and ASME relief valve for 50 lbs.
Optional equipment:
Steel pedestal bases for installation under the regularly fur nished 12' base for greater base heights will be furnished when specified on order at the following added charges:
section size 5 thru 7 8 thru 12
bate heights 8"
10"
added charge *44.00 72.00
For low water cut-off for A-7 steam boilers, see page 32.
a For complete information on boiler ratings, see page 2.
For discount on repairs, see page 2.
HH-2
Pase 34
04563
STEAM
boiler number
WATER
S-153-D S-154-D S-155-D
W-153-D W-154-D W-155-D
AMERicAN-<Standard
HYDRONIC HEATING
ARCOLINER HAND FIRED
Factory assembled sections. Dry base construction.
Flush jacket.
BOILERS
HANDFIb^B6rttKs
gross output
Mbh
sq ft steam
n*t Install**! rating Mbh
q ft water
Trad* Price
approx. shipping
weight
102 180 43.2 288 $286.00 771
152 272 65.3 435
334.00
928
204
373 89.4
596
384.00
1083
Standard Equipment:
Steam:
Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve.
Built-In Heaters: If Front Section arranged for but less Built-in screw-in heaters No. 701 or 702 is desired specify on order.
Below are the ratings and Trade Prices of Built-in heaters available for Arcoliner Dry Base steam boilers. For detailed information of ratings, see page 2.
Haatar No.
Haatar Typo
Haatar ratings gals, capacity
Trad* Pries
approx. shipping weight
701 tank 60 $8.50 5
702 tank 40
8.00
4
Note Built-in water heaters are not recommended for hand fired water boilers.
STEAM
boiler number
WATER
S-17 S-21 S-25 S-29
S-33 S-37
W-17 W-21 W-25 W-29 W-33 W-37
SEVERN HAND FIRED BOILERS
Flush jacket.
gross output
Mbh
sq ft steam
a net installed rating Mbh
tq ft water
Trade Price
approx. shipping
weight
194 244
296 328 364
396
353 84.7 453 108.7 553 132.7 630 151.3 710 170.5 783 187.9
565 725 885 1009 1137 1253
$374.00 432.00 494.00 544.00 599.00 646.00
1243 1413 1521 1686 1783 1956
Standard Equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve.
Built-in Heaters: If 2%" right or left side tapping in back section for Built-in screw-in heaters No. 701, 702 or 703 is desired specify on order and add $2.00 per tapping to Trade Price of boiler.
Below are the ratings and Trade Prices of Built-in heaters available for Severn hand fired steam boilers. For detailed information on ratings, see page 2.
Heater No.
Heeter Typo
Heeter retina gals, capacity
Trade Price
approx. shipping weight
701 tank 60 $8.50
702 tank 40
8.00
703
tank
100
9.00
Not*: Built-in water heaters are not recommended for hand fired water boilers.
5 4 7
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
Pig* 35
HH-2
04564
. HAND FIRED BOILERS
ITtAJM AMO WATER
STEAM
2-S-6 2S-7 2-S-8 2-S-9 2S-10 2-S-l 1 2-S-12
boiler number
WATER
2-W-6 2-W-7 2-W-8 2-W-9 2-W-10 2-W-ll 2W-12
American-^Standard
HYDRONIC HEATING
NO. 2 REDFLASH HAND FIRED BOILERS
Jacketed and unjacketed.
grot* output
Mbh
net Installed ratine
sq ft itum
Mbh
q ft water
unjackeied
Trade Price
390 464 536 606 676 744 812
769 940 1111 1281 1453 1623 1794
184.7 225.7 266.7 307.5 348.8 389.5 430.5
1231 1505 1778 2050 2325 2597 2870
$ 596.00 673.00 749.00 821.00 892.00 965.00
1041.00
1966 2293 2466 2782 2999 3313 3503
ih
sn
Trade Price
$ 657.00 737.00 817.00 893.00 969.00
1045.00 1124.00
approx. shipping weight
2091 2390 2572 2897 3122 3446 3644
Standard Equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve.
boiler number
STEAM
WATER
3-S6 3-S-7 3-S-8 3-S-9
3-W-6 3-W-7 3-W-8 3-W-9
NO. 3 REDFLASH HAND FIRED BOILERS
Jacketed and unjacketed.
gross output
Mbh
696 814 932 1046
net installed rating
sq ft steam
Mbh
sq ft water
1503 1799 2100 2400
360.6 431.8 504.1 576.0
2404 2879 3360 3840
un|acketed
Trade Price
approx. shipping weight
$ 912.00 1046.00 1184.00 1324.00
3243 3698 4110 4549
jacketed
Trade Price
approx. shipping weight
$ 988.00 1127.00 1272.00 1415.00
3397 3870 4285 4732
Standard Equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
Water Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve.
Note Buckwheat coal grate bars will be furnished at no additional charge when specified on order.
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-2
Pag* 36
04565
American'^Standard
HYDRONIC HEAT J N Q
A-7 HAND FIRED BOILERS
`j~r
Jacketed and unjacketed.
Tested and equipped for 50 lbs. water working pressure
boiler number
STEAM
WATER
A-705-S A-705W A-706-S A-706-W A-707 S A-707-W A-708S A-708-W A-709-S A-709-W A-710S A-710-W A-711-S A-711-W A-712S A-712W
gross l=B=:R output
Mbh
net l=B=R
sq ft steem
Mbh
1122 1298 1510 1708 1910 2108 2288 2456
2606 3101 3725 4342 5008 5681 6326 6947
625.4 744.3 894.0 1042.1 1202.0 1363.5 1518.2 1667.3
net rating sq ft water
chimney size
4169 16 x 16 x 40 4962 16 x 20 x 45 5960 20 x 20 x 50 6947 20 x 20 x 55 8013 20 x 20 x 60 9090 20 x 24 x 65 10122 20 x 24 x 70 11115 24 x 24 x 75
unfacke led
Trade Price
approx. shipping
weight
jacketed
Trade Price
approx. shipping
weight
$1327.00 1447.00 1615.00 1788.00 1910.00
4294 5006 5738 6392 7199
$1408.00 1533.00 1713.00 1904.00 2048.00
4466 5181 5921 6601 7334
2061.00 7858
2207.00 8077
2225.00 8506
2381.00 8767
2377.00 9231
2544.00 9529
Standard equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
Water: Theraltimeter and ASME relief valve for 50 lbs., automatic damper regulator and firing tools.
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
Pag# 37
C4566
HH-2
RADIATORS
Ame rican-<S>tandard
HYDRONIC HEATING
ARCO RADIATORS
width
6 tube 3 tube 4, 5, 6 tube 4, 5 tube 4, 6 tube
height Inches
32 25 25 22 19
Trade Price per sq ft
(1.19 1.19 1.12 1.17 1.19
Three, four, five and six tube Arco Radiators are regularly furnished with two and one-half inch (2 Vi") legs but can be supplied on Special Order with four and one-half inch (4H-) legs, or without legs, at no extra charge.
Arco Radiators sold only in even number of sections up to a maximum of 56 sections.
SUNRAD RADIATORS
type
Trade Price per sq ft
M 5x20 M 7i/2 x 23
$1.42 1.49
M 5 x 20 and M 7V4 x 23 Sunrad Radiators are regularly fur nished with two and three-quarter inch <2%") legs but can be supplied on special order without legs, at no extra charge.
Sunrad Radiators sold in even number of sections from 4 to 30 sections, and in odd number of sections with center leg from 31 to a maximum of 45 sections.
PEERLESS WALL RADIATORS
type
Trade Price per sq ft
11-B Pattern 8-B Pattern
$1.28 1.34
Extra charge of $0.60 each will be made for tappings at Nos. 20, SO, 60 and 90 as shown on outline drawings of Peerless Wall and Ceiling Radiators in current literature.
Radiators furnished per Figures 840 or 1140 add $2.40 trade extra
Radiators furnished per Figures 842 or 1142 add $4.80 trade extra
For convenience in handling and shipping, Nos. 8-B and 11-B Radiators will be assembled in lengths not exceeding 4 sections.
height In
Inches
32 25 22 19
RATINGS - SQUARE FEET PER SECTION
Arco Radiators Sold only in even number of sections
3 tube
sq ft per section
4 tube
5 tube
CO
H
1.6 2.0 2.4 2.1
1.6
6 tube 3.7 3.0
2.3
Peerless Wall Radiators
1 I B Pattern.................................................. 11 sq ft per section 8-B Pattern.................................................. 8 sq ft per section
'Sunrad Radiators
M 5 x 20 Pattern........................................2.25 sq ft per section M 7>/2 x 23 Pattern................................... 3.40 sq ft per section
`Important: Increase size 5% for recessed Installation--*4" air space
top and sides. Vt" at back. Increase size 15% for tightly recessed In-
steilation--no clearance top or sides.
air space at back.
HH-2
Paga 38
04567
American-Standard
HYDRONIC HEATING
BASEBOARD PANELS RADIATOR ACCESSORIES
RADIATOR ACCESSORIES
Arco Bracket*: For 3, 4, 5. 6 tube, with Wall Plate...............................
Arco Radiator Pedestal*: `A* and X".......................................................................
iVi" ...................................................................................
Sunrad Brackets: For M5 x 20 and M7>/2 x 23........................................
Peerless Wall and Celling Brackets: Adjustable, with Bearing Plate,single spool.............. Adjustable, with Bearing Plate,double spool............. TypeL .............................................................................. Type M .............................................................................. Type MM ......................................................................... Type P ..............................................................................
Trad* Wei *ch $0.79
0.30 0.39
0.62
3.B5 6.99 0.22 0.15 0.22 0.47
NippJec. Plug*. Rn*hlrgr
Trade Prlca ttrh
Vi". 1", 1V*", ll/z" Plugs, Bushings.......................... Vi". 1", 1V4" Slip Nipples............................................. 1 VS" Hexagon Nipples.................................................. Vi" Air Vent Plugs......................................................... Radiator Rod Nuts........................................................... Radiator Rods............................................... per section
$0.22 0.22 0.39 0.01 0.01 0.01
Abova Items available for ua only with our Radiator products.
Sunrad Grilles Inlet--Stamped Lattice Type............................................per section SO.18
SHIPPING WEIGHTS
For estimating purposes only, the following approximate weights per square foot may be used tor radiators: Arco. 444 pounds; Sunrad, M5 x 20-6 pounds, U7H x 23--644 pounds; Peerless Wall, 644 pounds; New Model 8 Radiantrim Panels: 444 pounds per square foot, 12.16 pounds per lineal foot; Model 10 Radiantrim Panels: 444 pounds per square foot, 16.15 pounds per lineal foot.
For estimating purposes only, the following approximate shipping weights may be used for Convectors and Cabinets:
Arco Convectors-elements only-see page 45.
Complete Cabinets, for Arco or Multifln Convectors, per sq ft of cabinet output-144 pounds.
Multifin Convectors-elements only-see page 42.
Multifln Units (convectors shipped mounted in cabinets) per
sq ft of cabinet output-
``Spacial Service Une'*
Types F, R, RC-1% pounds. Type W-144 pounds.
Type FS
-144 pounds. Type S -144 pounds.
"Stock Model"-1.13 pounds; also see pages 43 and 44.
Heatrim Panels see pages 40 and 41.
l = B=R Steam Rating per lineal foot 2.75 sq ft
per lineal foot
per square foot
Trade Price* $3.06
$1.12
New Model 8 Radiantrim Panel lengths (244 ft to 30 ft) are made up from the following sections:
144 ft Left hand end section
1 ft Right hand end section
2 ft Left hand end section
2 ft Right hand end section
2 ft Center section
Assembly length with legs and tappings at each end:
2 ft Double end section
l=B=R Steam Rating per lineal foot 3.4 sq ft
per lineal foot
per square foot
Trade Price- $3.81
$1.12
Model 10 Radiantrim Panel lengths (244 ft to 30 ft) are made up from the following sections:
144 ft Left hand end section
1 ft Right hand end section
2 ft Left hand end section
2 ft Right hand end section
2 ft Center section
Assembly length with legs and tappings at each end:
144 ft Double end section
2 ft Double end section
New Model 8 Accessories
prfo
Extension Panel and Brackets
(Two 6 ft lengths per box) ...................................... $8.40 Extension Panel Retaining Bracket............................ 0.22
Extension Panel Cover Strip........................................ 0.53
Assembly Clamp .............................................................. 7.70 Compression Corner Connection ................................ 2.40
Retaining Block ................................................................ 0.15
Adjustable Leg .................................................................. 0.20
Tie Bolt ............................................................................... 0.06
These items ere regularly furnished as required with New Model 8 Radtantrim Panels end Accessories. Prices are shown for repair or re placement purposes.
Packed In quantity of 10 per box (Available only in this minimum quantity)
Inverted Comer Cover............................................ Extended Inverted Comer Cover.......................... Projecting Comer Cover........................................ Valve Enclosure (all R.H. or L.H.) .................... End Box (all R.H. or L.H.) ..............................
Trade Price per box of 10
$10.50 17.50 14.20 12.35 7.00
Model 10 Accessories
price
Extension Panel and Brackets
(Two 6 ft lengths per box) . ....................................... $13.10
Extension Panel Retaining Bracket............................ 0.22
Extension Panel Cover Strip........................................ 0.53
Assembly Clamp ............................................................... 7.70
Compression Corner Connection.................................. 2.40
Retaining Block ............................................................... 0.15
Adjustable Leg ................................................................. 0.20
Tie Bolt ............................................................................... 0.06
These items are regularly furnished as reouired with Mode! 10 Ra
diantnm Panels and Accessories. Prices are shown for repair or re placement purposes.
Packed in quantity of 10 per box (Available only in this minimum quantity)
Inverted Comer Cover ................. Extended Inverted Comer Cover Projecting Corner Cover .............. Valve Enclosure (aU R.H. or L.H.) End Box (all R.H. or L.H.) ..........
Trade Price per box of 10
..$13.10 . 23.60
.. 16.60 .. 18.35
9.80
Page 39
04568
HH-2
ejjuACf asAoa:?:Ai:
WEATRIM-PANELS Atl- 'f
AMERidAN-^tandard
HYDRONIC-HtATINO
SEE CURRENT LITERATURE FOR APPROVED I-B-R HOT WATER RATINGS
dncriptlon
approx. shipping weight
Trad* Prtca
COMPLETE UNITS:
Model N85-L-Packaged in 3', 4\ 5'. 6', and 8' lengths-completely assembled (package contains element, one-piece back and top section, front panel, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint.
( per 3 ft. length l per 4 ft. length < per 5 ft. length 1 per 6 ft. length l per 8 ft. length
*per lineal foot
9 $ 5.85 12 7.80 15 9.75 18 11.70 24 15.60
3 1.95
Model N85HH-Packaged in 3'. 4', 5-, 6'. and 8' lengths-completely assembled (package contains element, one-piece back and top section, front panel, splitter/damper, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint.
f per 3 ft. length 1 per 4 ft. length ( per 5 ft. length 1 per 6 ft. length l per 8 ft.length
*per lineal foot
12 7.35 16 9.80 20 12.25 24 14.70 32 19.60
4 2.45
HEATING ELEMENTS: Model N85 (4" tube)-Packaged six equal lengths per box.
f per box of six 3' lengths j per box of six 4' lengths ( per box of six 5' lengths 1 per box of six 6' lengths V per box of six 8' lengths
*per lineal foot
Model N85 <%" tube)-Individually packaged one per box.
/ per box of one 3' length 1 per box of one 4' length
j( per box of one 5' length per box of one 6' length l per box of one 8' length
per lineal foot
Model HO <1" tube)-Packaged eight 6' lengths per box.
*For comparative and estimating purpoeos only. MM*2
per box of eight -per lineal foot
Riga 40
18 24 30 36 48
1
3 4 5 6 8 1
79%
1%
18.00 24.00 30.00 36.00 48.00
1.00
3.21 4.28 5.35 6.42 8.56 1.07
94.08 1.96
04569
AMfewcSff-^tandartl HY'O R'O'N C H EAT1 N O
HEATRIM PANEL Accessories
HEATRIM BASEBOARD PANEL. ACCESSORIES
ENCLOSURES; Model L-Multiple packaged in 3*. 4'. S', 6', and 8' lengths-- three equal lengths per box (package contains 3 one-piece back and top sections, 3 front panels, loose snap-in support brackets, element slide cradles and 3 sets Joining pieces). Fin ished with white prime coat of paint.
Model L-Individually packaged in 3', 4', 5', 6' and 8' lengths unassembled. (Package contains one-piece back and top sec tion, front paneL loose snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint.
Model HH-Multiple packaged in 3', 4', 5', 6', and 8' lengthsthree equal lengths per box (package contains 3 one-piece back and top sections. 3 front panels, 3 splitter/dampers, loose snap-in support brackets, element slide cradles and 3 Bets joining pieces). Finished with white prime coat of paint.
Model HH-Individually packaged in 3', 4', 5', 6' and 8' lengths unassembled. (Package contains one-piece back and top sec tion, front paneL splitter/damper, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint.
V*
'-! *
per box of three 3' lengths per box of three 4' lengths per box of three 5' lengths per box of three 6' lengths per box of three 8' lengths
per lineal foot
per 3 ft. length per 4 ft. length
per 5 ft. length per 6 ft. length per 8 ft. length
per lineal foot
per box of three 3' lengths per box of three 4' lengths per box of three 5' lengths per box of three 6' lengths per box of three 8' lengths
per lineal foot
per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length
per 8 ft. length
per lineal foot
shpipprpoinx.g ,...
18 24 30 36 48
2
6 8 10 12 16
2
if*
84
3 V4
a* 17Vz
21 28
3V4
For comparative and estimating purposes only.
OMcrtptlon
approx. swhiaplpgihntg
MODEL L ENCLOSURE ACCESSORIES:
Inverted Comer Cover-one-pieee front and top section......... Inverted Comer Cover-back section only.................................. Projecting Comer Cover..................................................................
Valve Enclosure--6" wide.......................... packed all right hand< End Cover-4" wide..................................... packed all right hand< End Cap-U4" wide......................................packed all right hand<
Wall End Piece-3y" wide................................................................ One-Foot Filler Pieces--14" wide................................................... Joining Pieces--2" wide......................................................................
Note: Finished with white prime coat of paint.
....... packed per box of 10
all left hand per box of 10 all left hand per box of 10 all left hand per box of 10
packed per box of 20 sets
7 5 12
15 9 5
3 15 8
Dampers for Model L Enclosures: Packaged in twelve equal lengths per box.
Noto: Finished with white prime coat of paint.
f per 3 ft. length
per 4 ft. length < per 5 ft. length
per 6 ft. length i per 8 ft. length
per lineal foot
Replacement parts for Model L enclosures:
Enclosure fronts-8 ft. lengths only...........................................................................................each Snap-in support bracket with slide cradle............................................................................... each
12 16 20 23 32
V4
..
MODEL HH ENCLOSURE ACCESSORIES:
Inverted Comer Cover-one-piece front and top section........................ packed per box of 10 Inverted Comer Cover-back section only.................................................packed per box of 10 Projecting Comer Cover................................................................................. packed per box of 10
Valve Enclosure-6" wide...........................packed all right hand or all left hand per box of 10 End Cover-4" wide....................................packed all right hand or all left hand per box of 10 End Cap-U4" wide....................................packed all right hand or all left hand per box of 10
Wall End Piece--3V4" wide............................................................................... packed per box of 10 One-Foot Filler Pieces--14" wide..................................................................packed per box of 5 Joining Pieces-2" wide..........................................................................packed per box of 20 sets
Note: Finished with white prime coat of paint.
8 6 14
16 12
8
6 18
8
Replacement parts for Model HH Enclosures: Enclosure fronts-8 ft. lengths only............................................................................................ each Snap-in support bracket with slide cradle............................................................................... each
For comparative and estimating purposes only. NOTE: Add 25% to accessory unit price when ordered in less than quantities indicated above.
Pago 41
04570
' ' *`1 CflQk. `Tradt
:,' Prica $ 7.20 9.60 12.00 14.40 19.20
.80
2.70 3.60 4.50 5.40 7.20
.90
12.06 16.08 20.10 24.12 32.16
1.34
4.35 5.80 7.25 8.70 11.60
1.45
Trad* Pries
$ 8.00 4.50
10.00 17.50 12.50
5.00 3.00 6.00 5.00
5.40 7.20 9.00 10.80 14.40 .15
2.00 .35
8.00 4.50 11.50 18.00 12.50 8.00 4.00 7.75 7.00
2.40 .35
HH-2
CONVECTORS
1 Typa K (Slock Modal) Typo F (Special Sorvica)
nnunmmm
Typo KC (Stock Modal)
TypaS
Hiiiiiiinuiinn
Typo w
_____
UlUUUBBfflil
Type R
[hiiiuiuibuhi
HH-2
American-^Standard
HYDRONIC HEATING
MULTIFIN CONVECTORS
Pries!
The actual output in square feet of catalog rating-Steam (215'F.) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination.
The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of units ordered.
typ***
description
Stock Model
K KC
Floor Type-free standing.............................................................. Semi-recessed-2%" flanged edges..............................................
Trade Price
pnr sq ft
unit extra charge
$0.40 .40
$11.00 14.00
Note: For expanded prices, see pages 43 and 44. For cabinet extras, see page <6. special service
F FG W FS FSG S R RG RGB
RC RCG RCGB
RCGB
Floor Type--free standing-inlet grille.................................... Wall Hung-flat top........................................................................
Free Standing-sloping top.......................................................... Free Standing--sloping top-inlet grille.................................... Wall Hung-sloping top..................................................................
Recessed-44" flanged edges.......................................................... Recessed-H" flanged edges--inlet grille.................................. Recessed-V4" flanged edges-inlet grille with bottom
overlap.............................................................................................. Semi-recessed-2V4" or 4te" flanged edges.............................. Semi-recessed-2^4" or 4V4" flanged edges inlet grille.......... Semi-recessed-2^4" flanged edges-inlet grille-with bot
tom overlap.................................................................................... Semi-recessed-4%" flanged edges-inlet grille-with bot
tom overlap....................................................................................
$ .41 .44 .40 .43 .46 .37 .47 .50
.50 .47 .50
.50
.50
$12.00 12.00 12.25 13.75 13.75 12.25 13.75 13.75
16.75 14.75 14.75
17.75
17.75
Not*: For cabinet extras, see page 46.
Elements only (when sold less cabinets) -- steam or water
1
i u>
1
i*
convector length inchot
20 24
28 32 36
40 44 48
56 64
No. 4-3%' depth
approx. unit shipping no. weight
420 8 424 to
428 12 432 14 436 16
440 18 444 20 448 22
456 26 464 30
Trade Frica
( 8.40 9.10
9.80 10.40 11.15
11.85 12.40 13.10
14.50 15.90
No. 6
depth
approx.
unit shipping Trado no. woight Price
620 13 (10.75
624 16
11.65
628 19 632 22 636 25
12.60 13.45 14.30
640 28 644 31 648 34
15.25 16.10 16.95
656 40 664 46
18.75 20.50
No. a-7%" depth
unit no.
820 824
828 832 836
840 844 848
856 864
approx. shipping weight
15 19
23 27 31
35 39 43
51 59
Trade Price
(13.90 15.10
16.35 17.60 18.80
20.05 21.30 22.55
25.00 27.50
No. 10-9%" depth
unit no.
1020 1024
1028 1032 1036
1040 1044 1048
1056 1064
approx. shipping
weight
Trade Price
21 (19.30 26 20.55
31 21.85 36 23.10 41 24.40
46 25.60 51 26.90 56 28.20
66 30.70 76 33.25
Ratings:
Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined'in Commercial Standard Code CS140-47 and amendments and said ratings have been approved by the Convector Rating Committee.
Standard Cabinets:
Standard cabinets are furnished in prime painted sheet steel-reinforced, No. 18 gauge front and No. 20 gauge back (K and KC-No. 26 gauge), ends and top rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate con vectors listed in current literature.
ONE-PIPE STEAM:
Particular reference must be made on order if special service convectgrs are to be used on onepipe steam systems. Multifin convectors-for two-pipe steam or water systems-cannot be used, or modified, for one-pipe systems.
Elements arranged with special one-pipe steam headers--$.06 Trade Price per square foot of cabinet output extra.
Pag* 42
04571
Ame rican-^Standard
H YD RON I C HEATING
CONVECTORS
MULTIFIN CONYECTORS
TYPE rv -- STOCK MODEL -- r*EE STAriDiriG Expanded prices
For use on two-pipe steam and hot water systems only.
cabiaat li*f(b iaNt
No. 4 depth (4 VI" cabinet)
Mil
4 ft avtpal
MfMihippiaf
Trade Frica
20" cabinet height
No. 6 depth (6Vi' cabinet)
Mil a.
H ft Mfpvt
FF* ihaiwi|h'Mt
Trad# Fria
No. 8 depth (8Vi" cabinet)
vail aa.
*4 ft mtpvl
ibIHiRWRia-f araiffel
Trada Frill
No. 10 depth (10Vi" cabinet)
vait a.
*4 ft avfpvl
aRRrai. h'M'M waifhl
Trada Fria
20'/, 420-20 11.3 13 $15.52 620-20 16.3 24 $17.52
24'/, 424-20 13.9 16
16.56 624-20 20.1 27
19.04
28 'h 32V4
628-20 632-20
23.8 27.6
30 34
20.52 22.04 832-20 33.6 38 $24.44
36 'h
636-20 31.3 36
23.52 836-20 38.1 42
26.24 1036-20 42.4 48
40'/,
640-20 35.1 40
25.04 840-20 42.7 45
28.08 1040-20 47.6 52
44 Vi
644-20 38.8 43
26.52
48'/,
648-20 42.6 46
28.04 848-20 51.8 52
31.72 1048-20 57.8 58
56'/,
656-20 50.1 53
31.04 856-20 60.9 60
35.36 1056-20 68.0 67
64'/a
664-20 57.6 59
34.04 864-20 70.0 65
39.00 1064-20 78.2 76
$27 96 30.04
34.12 38.20 42 28
24" cabinet height
20 Vi 24 Vi 28'/, 32'/, 36'/, 40 Vi 4*'/, 48'/, 56'/, 64 Vi
420-24 424-24 426-24
13.1 16.1 19.1
15 18 22
16.24 17.44 18.64
620-24 18.4 624-24 22.7 628-24 26.9 632-24 31.1 636-24 35.4 640-24 39.6 644-24 43 8 648-24 48.1 658-24 56.5 664-24 65.0
28 32 37 39 40 46 50 52 60 69
18.36 20.08 21.76 23.44 832-24 25.16 836-24 26.84 840-24 28.52 30.24 848-24 33.60 856-24 37.00 864-24
37.9 43.0 48.2
58.4 68.7 78.9
43 46 51
5a 66 74
26.16 28.20 1036-24 30.28 1040-24
48.6 54.4
52 56
34.36 38.48 42.56
1048-24 1056-24 1064-24
66.1 77.8 89.5
64 74 83
30.44 32.76
37.44 42.12 46.80
32" cabinet height
Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown
on page 39.
Special air vent assemblies. Trade Price.................. each $1 80 Damper, chain type-standard length, Trade Price, each 2 10
Metal trim strips. Trade Price Snap-On inlet grille. Trade Price.
each $2 75 2 75
Page 43
04572
HH-2
CONVECTORS
American-c$tadat>d
HYDRONIC HEATING
IHHiiiir553
|
i
MULTIFIN CONVECTORS
TYPE KC - STOCK MODEL - PARTIALLY RECESSED Expanded prices
For use on two-pipe steam and hot water systems only.
No. 6 depth <6 Vi " cabinet) with 2Vi" flange
cabinet length Inches
approx.
unit
sq ft
shipping
Trade
no.
output
weight
Price
20" CABINET HEIGHT
20Vi 620-20 16.3 24 $20.52 24Vi 624-20 20.1 27 22.04 28Vi 62&-20 23.8 30 23.52 32'/2 632-20 27.6 34 25.04 36Vi 636-20 31.3 36 26.52 40Vi 640-20 35.1 40 28.04 44Vi 644-20 38.8 43 29.52 48Vi 648-20 42.6 46 31.04 56Vi 656-20 50.1 53 34.04 64Vi 664-20 57.6 59 37.04
No. 6 depth (6V4" cabinet) with 2Vi" flange
cabinet length inches
unit no.
sq ft output
approx. shipping weight
Trade Price
24" CABINET HEIGHT
20Vi 620-24 18.4 28 $21.36 24Vi 624-24 22.7 32 23.08 28Vi 628-24 26.9 37 24.76 32Vi 632-24 31.1 39 26.44 36Vi 636-24 35.4 40 28.16 40Vi 640-24 39.6 46 29.84 44Vi 644-24 43.8 50 31.52 48Vi 648-24 48.1 52 33.24 56Vi 656-24 56.5 60 36.60 64Vi 664-24 65.0 69 40.00
Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 39.
Special air vent assemblies. Trade Price................................................................................each $1.80
Damper, chain type-standard length. Trade Price
. .each 2.10
Snap-On inlet grille. Trade Price............................
.......................... each 2 75
H H-2
Pig* *4
04573
AwERiCAN-c^tacdat^ HYDRONIC HEATING
CONVECTORS
ARCO CONVECTORS
SPECIAL SERVICE LINE when sold in combination with standard cabinets
COMBINATION PRICE:
The actual output in square feet of catalog rating--Steam (215'F) obtained with the cabinet heights furnished deter mines the price of convectors and cabinets sold in combination.
The total price of each order equals the amount of catalog
square feet ordered multiplied by the price per square foot, plus the unit extra charge muitipled by the total number of units ordered.
cabinet type
description
Trade Price
Per %q ft
unit extra charge
F FG
W FS FSG
S R RG
Floor Type-free standing___ $1.29
Floor Type-free standinginlet grille..........................
1 11
Wall Hung-flat top............
1.29
Free Standing-sloping top ...
Free Standing-sloping topinlet grille............................
Wall Hung-sloping top..........
Recessed-t4" flanged edges . .
1.35
1.38 1.29 1.28
Recessed-t4" flanged edgesinlet grille..........................
1.31
$16.30
16 30 16.30 17.10
17.10 16.30 17.30
17.30
Standard Cabinets are furnished in: Prime painted sheet steel-reinforced. No. 18 gauge front and No. 20 gauge back, ends and top. rounded corners, streamline
For illustrations of cabinets, see pape 42.
For cabinet extras, see page 46.
catybpin#et
.descri.ption
Trad# Pries
par sq ft
unit extra charge
RGB Recessed-- H " flanged edges-- inlet grille with bottom overlap ........................
$1.31
$20.30
RC Semi-recessed-2V4" or 4V4" flanged edges ......................
RCG Semi-recessed-214" or 4V4" flanged edges-inlet grille ..
1.28 1.31
18.80 18.80
RCGB Semi-recessed-2" flanged
edges-inlet grille-with bottom overlap....................
1.31
21.80
RCGB Semi-recessed--4V4 " flanged edges-inlet grille-with bottom overlap....................
1.31
21.80
front discharge grille, and open bottom inlet arch, in heights,
lengths and depths to accommodate convectors listed in cur rent literature.
ARCO CONVECTOR -- steam or wafer
ELEMENTS ONLY (when sold less cabinets)
convector length Inches
18 23 28 33 38 43 48 53 58 63
No. 4 33/4" depth
unit no.
approx. shipping
weight
Trade Price
418 39 $11.82
423 50 15.26 428 61 18.69
433 72 22.14 438 83 25.58
443 94 28.91 448 105 32.33
453 107 35.78 458 128 39.23
463 139 42.66
6No. 5s/g" depth
unit no.
approx. shipping weight
Trade Price
618 57 $17.41
623 73 22.45 628 90 27.52
633 106 32.67 638 123 37.73
643 139 42.78 648 146 47.83
653 172 52.87 658 189 57.92
663 206 63.07
No. 8 7s/a" depth
unit no.
approx. shipping weight
Trade Price
818 71 $21.92
823 92 28.37 828 113 34.83
833 134 41.27 838 155 47.61
843 176 54.05 848 197 60.50
853 218 66.95 858 239 73.40
863 260 79.83
No. 10 9i/2" depth
unit no.
approx. shipping
weight
Trade Price
1018 84 $26.44
1023 110 34.17 1028 136 42.01
1033 162 49.74 1038 188 57.59
1043 213 65.33 1048 238 73.17
1053 264 81.01 1058 289 88.76
1063 314 96.48
Arco Convectors in lengths and depths indicated above are Standardized Sizes when sold with or without cabinets. For sizes not listed above-price on application.
Page 45
04574
HH-2
CONVECTORS
American-^Standard
HYDRONIC HE AT INQ
CABINET EXTRAS FOR MULTIFIN AND ARCO CONVECTORS
HH-2
CABINET EXTRAS-STOCK MODEL MULTIFIN ONLY
1. Chain type dampers ..................................................................................................... each 2. Metal trim strips (type Konly) ...............................................................................each 3. Snap-on inlet grilles......................................................................................................each 4. Special air vent assemblies..........................................................................................each
Trade Price
$2.10 2.75 2.75 1.80
SPECIAL SERVICE CABINET EXTRAS-MULTIFIN AND ARCO CONVECTORS
1. Chain type dampers ..................................................................................................... each 2. Knob type dampers........................................................................................................each 3. Marking or tagging-room number or location.................................................... each
4. Access doors-lift-off type ......................................................................................... each 5. Access doors-piano hinge type ............................................................................... each 6. Stool outlet-regular sheet price, plus............................................................................
7. Extra length-per inch or fraction thereof.................................................................... 8. Rotary cam locks............................................................................................................ each 9. Screws other than standard slotted type-per convector........................................
10. Grille reinforcing angles-6" centers-per grille........................................................ 11. Heavier gauge cabinets-trade price per sq ft of cabinet output:
2.10 2.90
.20
2.50 2.90 1.40
.60 .70 .30
1.00
fronts only
No. 18 gauge ......................................................................................
$ . ..
No. 16 gauge ......................................................................................
.04
No. 14 gauge ...................................................................................... 12. Insulation--trade price per sq ft of cabinet output:
.09 back only
Aerocor-1" thick compressible to hk".................................... $0.12
Wood Fiberboard--thick........................................................
.12
Asbestos Millboard-y<" thick....................................................
.12
Asbestos Millboard- W thick....................................................
.18
13. Front panels only: 50% of complete convector unit price (based on No. 6 depth)
14. Cabinet only: 70% of complete convector unit price
15. Providing round pipe holes or knockouts ........................................ 16. Providing special shape cutouts............................................................
liners only $0.04 .06
.10
back, ends, and top $0.18 .24 .24 .36
price on application price on application
NOTES APPLICABLE TO MULTIFIN CONVECTORS ONLY:
Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 39.
MINIMUM CABINET HEIGHTS WITH DAMPERS
Multifin Convectors: Types FS. FSG
Chain Type Dampers
18" for ff4 Depth 20" for #6 Depth 24" for if 8 4c if 10 Depths
Knob Type Dampers
18" for -4 Depth 20" for -6 Depth 24" for 8 4c if 10 Depths
Type S
Arco Convectors: Types F. FG, W
14" for "4 & if 6 Depths 18" for Jf8 4c if 10 Depths
20" For All Depths
14" for -4 4c if 6 Depths 18" for ff8 4c - 10 Depths
20" For All Depths
Types FS. FSG
24" for ~ 4,~ 6 & r8 Depths 26" for if 10 Depth
24" for -4."6 4e "8 Depths 26" for "10 Depth
Type S
18" for if 4 Depth 20" for #6 Depth 26" for *84c if 10 Depths
18" for "4 Depth 20" for if 6 Depth 26" for *8 4c #10 Depths
Types R. RG, RGB, RC, RCG, RCGB
24" For All Depths
20" For All Depths
NOTE: Minimum heights for Arco Convectors appucaoie to x 4 (underneath) connection only
Page 46
04575
American -<>t andard
HYDRONIC heating
TERMS
TRADE PRICE BOOK
Illustrations and descriptions of Plate Numbers listed in this price book will be found in the current AmericanStandard Heating-Cooling Products Catalog and literature. Items illustrated in product literature and not included in this price book are discontinued. The illustrations in this price book although actual representations of certain product in the line, do not necessarily show sires and details of all products in the line.
This book contains suggested Trade Prices for certain Hydronic Heating products sold by American Radiator & Standard Sanitary Corporation ("American-Standard") through its Plumbing and Heating Division. (AmericanStandard acting through that Division is hereinafter referred to as the "Seller"). The Seller assumes no obligation to sell to anyone at any price any of the items listed herein.
All prices herein set forth supersede all prior price lists and are subject to change without notice. The Seller may also, from time to time, discontinue without notice the sale of any of the products listed herein.
INVOICE MINIMUM An order for items for which invoice prices aggregate less than $1.00 will be billed at $1.00.
TERMS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY AMERICAN-STANDARD THROUGH ITS PLUMBING AND HEATING DIVISION
All sales of goods by American-Standard through its Plumbing and Heating Division are made subject to terms and conditions printed below, in its bulletins and on its acknowledgment of order, invoice and quotation forms. These terms and conditions are as follows:
PRICI
Goods sold bv the Seller wilt be billed to the Buyers according to the prices and terms contained in its current bulletins and price books. In the case of orders for goods for which no price is currently in effect, the price will be determined by the Seller and set forth in the invoice issued after shipment of the goods
Taxes. Any tax or other Government charge now or hereafter levied upon the ptoduction. sale, use or shipment of goods ordeied or sold, will he charged to and paid for by the Buyer
DELIVERY
Transportation Risks. Delivery to the initial carrier shall constitute dchvciy to the Buvci The Seller s icsponsibiiity ceases upon delivery in good Older to such cnuiei. and all goods ate shipped at the Buyer s risk.
The Buvcr is uiged to examine all deliveries carefully before signing ii anspot tation receipts If goods aie visibly damaged, the Buyer should insist that written confirmation of the damage be noted on the freight bill or dray ticket by the agent of the carrier If damage is discovered after unpacking, the earner should be notified at once, so that inspection can be made and the claimed damage substantiated by the earner
Interference with Deliver;. The Seller has no obligation to deliver goods against any ordet until it has accepted the order by issuance of its ac knowledgment of Older In any event, the Seller will not be liable for any dcla\ oi failure in the delivery or shipment of goods against an accepted oidci' or for an> damages suffered by reason thereof, when such delay or failure is, directly or indirectly, due to accident (in manufacture or other wise). fire, flood not, war, embargo, labor stoppages, inadequate transpoi tation facilities, shortage of material or suppltes. delay or default on the part of its vendors regulation by Government authority, or anv like oi dissimilai cause oi causes beyond its control
WARRANTY
Except whcic a different express written warranty has been issued with icspcCt to parliculai products no warranty express or implied, is extended by the Sellci to ans pci son or persons other than its distributors and othci dnect Du\eis To direct Buyers. the Seiler warrants only that it will fuimsh bv ficight a replacement for. or at its option repair, am pioduci of its manufactuie or part or poition thereof, proved to its satis1,k lion to he defective in material oi woikmanshtp under normal use and sei vice within one \cai aftei installation The Seller will not be respon sible foi an\ damages whatsocvei or for labor expense, in connection with the icplaccmcnt of defective pioducts or parts or portions thereof
This wai rant\ is in lieu of all othei wairantics. express or implied, and of all othcr obligations or liabilities, on the part of the Seller The Sellei ncithci assumes not authoi i/es anv othei pei son to assu me for it anv othei liabilities in connection with the sale of its products except in the case of vmhcss watt antics which may be issued b> it in willing from time to time with icspcet to paiticular pioducts
Goods of othei manufaciui ci s sold by the Seller are not warranted except by cxpicss wauanlics wmch may be issued in writing fiom time to time with icspcct to paiticulai products or particular sales, but tnc b.-Uei will endeavor to secuic for its direct Buyers the benefits of wai tantics extended bv the manufaciui vt s of such goods sold but not rr.anufact u i cd o> the Scl lei
CONTRACT WITH BUYER Acceptance of Orders. Orders will be accepted only by the Seller s usual acknowledgment of order containing terms and conditions applicable thereto No terms and conditions appearing in a Buyer s order that are at variance with the Seller's terms and conditions shall be binding upon the Seller unless specifically agreed to by it in writing. Unless the Seller spe cifically so agrees in writing in acknowledging any order, any terms and conditions appearing In a Buyer's order contrary to those stated herein and in such acknowledgment of order are to be deemed waived by the Buyer. Receipt by the Buyer of the acknowledgment of order without prompt objection to the terms and conditions therein and herein set forth, constitutes acceptance by the Buyer of such terms and conditions
Cancellation of Orders. Alter the Seller's acknowledgment of order has been issued, an order may be modified or cancelled only upon written agreement by the Seller. Orders for goods other than those of standard manufacture will not be cancelled after a commitment has been made or production scheduled.
Credit for Returned Goods. Merchandise may not be returned for credit unless the Seller has agreed to accept it Where returns are accepted, a deduction of lOCi will be made for rehandling. All transportation costs for returned goods must be paid by the Buyer In any event, only salable merchandise of standard manufacture may be returned for credit
Credit Approval. Buyers' orders are accepted subject to credit investiga tion and approval, and delivery may be withheld or shipment stopped in transit on accepted orders without any liability on the Seller s part. If, in its opinion, the Buyer s ability to pay for the merchandise on these terms and conditions is in doubt.
SHORTAGES OR VARIANCES
No claims for variances from or shortages in orders will be considered unless presented within GO days after receipt of goods
PRODUCT AND PACKAGING CHANGES
Factors beyond the control of the Seller and the need for continuing improvement of product require the making of changes from time to time in products and their packaging The right is reserved to make reasonable changes of any kind without notice and to deliver revised designs or mod els of goods against any order, unless on the face of the acknowledgment of order this right is specifically waived.
The Seller shall have no responsibility whatever with respect to changes made by the manufacturer in products (or their packaging) sold but not manufactured by the Seller
SHIPPING WEIGHTS The shipping weights given herein are approximate, for Buyers con venience only, and are not guaranteed
AMERICAN RADIATOR & STANDARD SANITARY CORPORATION
PLUMBING AND HEATING DIVISION
Page ij
04576
HH 2
SALES OFFICES
AMERic^*c$tandard
HYDROPIC' HCATItiO
ATLANTA 3110 Maple Drive Atlanta 5. Georgia
BALTIMORE 3006 W. Cold Spring Lane Baltimore 15, Maryland
BOSTON 31 St. James Avenue Boston 16, Massachusetts
BUFFALO 1807 Elmwood Avenue Buffalo 7, New York
CHICAGO 130 East Randolph Drive Chicago 1, Illinois
CINCINNATI 1077 Celestial Street Cincinnati 2, Ohio
CLEVELAND Euclid Avenue and East 14th Street Cleveland 15, Ohio
DALLAS 2501 Cedar Springs Road Dallas 1, Texas
DENVER 1550 East 17th Avenue Denver 18, Colorado
DETROIT Suite 1440, Maccabees Building Detroit 2, Michigan
HOUSTON 3400 Montrose, Suite 218 Houston 6, Texas
KANSAS CITY 4709 Belleview Street Kansas City 12, Missouri
LONG ISLAND 39-01 Main Street Flushing 54, Long Island, New
LOS ANGELES 141 El Camino Beverly Hills, California
MIAMI 46 N. E. Sixth Street Miami 18, Florida
MILWAUKEE 208 E. Wisconsin Ave. Milwaukee 2, Wisconsin
MINNEAPOUS 529 S. 7th Street Minneapolis 15, Minnesota
NEWARK 972 Broad Street Newark 2, New Jersey
NEW ORLEANS 2400 Canal Street New Orleans 19, Louisiana
NEW YORK 50 West 40th Street New York 18, New York
PHILADELPHIA 30 N. 5th Street Camden 2, New Jersey
PITTSBURGH 714 Bessemer Bldg. Pittsburgh 22, Pennsylvania
RALEIGH 611 Tucker Street Raleigh, North Carolina
ST. LOUIS 2725 Clifton Avenue St. Louis 9, Missouri
SALT LAKE CITY 1879 S. Main Street Salt Lake City 15, Utah
SAN FRANCISCO 681 Market Street San Francisco 5, California
SEATTLE 306 West Republican Street Seattle 99, Washington
SILVER SPRING 8641 Colesville Road Silver Spring, Maryland
EXPORT SALES Export Marketing Department American-Standard 40 West 40th Street New York 18, New York
HH-2
American-Standard
PLUMBING AND KEATING DIVISION
AMERICAN RADIATOR & STANDARO SANITARY CORPORATION *9 WEST 40TH STREET NEW YORK 18, NEW YORK
Pag* 48
04577