Document repDzLbJnRdR2235Y22mQVJJ

o AMERicAN-^tandard *Hydronic Heating Equipment trade price book 'Hydronics . . . the science of heating and cooling with water. Boilers: PRODUCTS Gas--Packaged Units Boilers Only Electronic Control Systems Oil --Packaged Units Boiler--Burner Units Boilers Only Stoker Boilers Hand fired Boilers Radiation: Baseboard Panels --Radiantrim --Heatrim Convectors --Multifin -Arco --Cabinet Extras Radiators--Arco, Sunrad, Peerless Oil Burners and Controls Zone Control Sets Gas Conversion Burners Repair Parts Discounts Terms Sales Offices General Information PAGE 3-5 6-14 15 17 18-29 18-29 33-34 35-37 39 40-41 42-44 45 46 38-39 30-32 30 16 47 48 HH-2 JULY 5, 1961 notice: The Trade Prices shown herein do not include freight or cartage. American-Standard PLUMBING AND HEATING DIVISION AMtICAN AOIATO A STANDARD SANITAtT CORPORATION 04530 GENERAL INFORMATION AMERicAN-fStandard H YD RON I C HE ATI NO BOILER RATINGS Boiler ratings ("net I=B=R ratings of Mbh and sq ft of steam", "net rating sq ft water" and "installed radiation", where shown) represent the maximum net loads that may be connected to the boilers. Steam sq ft ratings are based on 240 Btu per sq ft and water sq ft ratings oh ISO Btu <170* water) per sq ft. Allowances have been made in these ratings for normal piping (covered) and pick-up loads and for heat ing domestic hot water under the following conditions: It is not necessary to increase the boiler size for domestic hot water supply when not more than two bathrooms are to be served or if the use of domestic hot water does not exceed seventy-five gallons in twenty-four hours. Sufficient radiation must be installed for the requirements of the building. In order to select the proper size boiler calculate the heat loss of the building, then divide this figure by 1,000 to get the heat loss expressed in Mbh. Select a steam or wster boiler which has a net Mbh rating equal to or greater than this fig ure using the appropriate steam or water column. See current literature for determining the size of radiators and convectors for hot water systems. For an installation where unusual conditions such as large pipe losses, intermittent heating, unbalanced systems, etc., are encountered, it is suggested to calculate the actual piping loss and estimate the pick-up factor to adjust the load and then select the boiler from the published gross output in Mbh (1,000 Btu per hour). GAS FIRED BOILERS The input and output ratings are approved by the American Gas Association. Ratings shown are for installations at sea level and at eleva tions up to 2,000 feet For altitudes above 2.000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. OIL FIRED BOILERS The firing rates or I=B=R burner capacity--gallons per hourare based on the use of oil having 140,000 Btu per gallon heat value, and with 10% CO: in the flue gas. When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity. When Built-in Tankless Heater is used increase the boiler size 12 Mbh for each bathroom in excess of two. STOKER FIRED BOILERS The firing rates or I=B=R burner capacity pounds per hourare based on the use of coal having 13,000 Btu per pound heat value. When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity. HAND FIRED BOILERS The ratings (installed radiation sq ft) are based on the use of stove or nut size bituminous coal, anthracite coal or coke with 13,000 Btu per pound heat value. See table below for select ing proper size boiler when using coal with less than 13,000 Btu per pound. When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity. BUILT-IN WATER HEATERS (for Arcoliner, Oakmont, Severn, Exbrook Boilers) All tank type Built-in water heaters are rated on the basis of raising the temperature of the domestic hot water 100*F. in three hours with a minimum boiler water temperature of 180*F. on automatically fired boilers and 212*F. on hand fired boilers. All tankless type Built-in water heaters are rated in gallons per minute on the basis of a minimum boiler water tempera ture of 180*F. on oil fired boilers. The maintaining of 180*F. boiler water temperature with rated flow through a tank less type Built-in water heater is dependent on the oil firing rate for the boiler. In those areas where excessive lime exists in the water, use of Built-in Tankless Type water heater is not recommended except when provision is made for regularly cleaning the heater. Use of Tank Type heater is recommended in hard water areas. WHEN PIPING LOSS IS NEGLIGIBLE The ratings (installed radiation) of steam boilers (all fuels) and coal (hand fired) water boilers may be increased by the percentages shown below when the piping loss of the installa tion is negligible. The ratings (installed radiation) of auto matically fired water boilers may be increased by 12% when the piping loss of the installation is negligible. ratings Installed radiation sq ft Staam (all fuais) Watar coal (hand flrad) Incraasa ratings by up to 250 251- 500 501-1000 1001-1500 1501-2000 2001-3000 3001-4000 over 4000 up to 400 401- 800 801-1600 1601-2400 2401-3200 3201-4800 4801-6400 over 6400 30% 28% 24% 21% 18% 15% 13% 12% WHERE COAL HAS LESS THAN 13,000 BTU CONTENT When selecting hand fired boilers for burning coal of lower heating value than 13,000 Btu per pound the following correc tion factors should be used. Multiply the net load by the proper factor and select the boiler with the corresponding rating (installed radiation sq ft). hitting valua of coal 13.000 ____ 12.500 .... 12.000 .... 11.500 ____ 11,000 ___ 10.500 ____ 10.000 9,500 9,000 .... .... correction factor . . 1.00 . . . 1.04 . . . 1.08 . . . 1.13 . . . 1.18 . . . 1.24 . . . 1.30 . . . 1.37 . . . 1.44 REPAIR PARTS-TRADE PRICES Boilers (all fuels^...................................................................................................................................................List Price, less 25% Gas Conversion Burners.......................................................................................................................................List Price, less 25% For List Prices see ''American-Standard Radiator Heating Repair Parts Catalog" 1956 Edition. Oil Burners................................................................................................................................................................. List Price, less 25% __________________ For List Prices see "American-Standard Arcofiame Oil Burner Repair Parts Catalog" 1956 Edition. HH-2 Page 2 04531 American-^Standard HYDRONIC HEATING PACKAGED BOILERS GAS FIRED W*TI PACKAGED G-2 American-Standard GAS BOILER Designed and equipped with controls lor forced circulation. Factory asssmbled and crated. Flush or Deluxe Jacket. Sections tested lor 30 lbs. water working pressure. "Eliminaire" (cast-in air eliminator in left end section). WATER ONLY packing boiler number A.(LA. 'MSDBf?t A.QJL tankiesa output heater IssWsH Mm number rating Mfd,, Nat, Mixed end U Gu; LP-AIr Gas 525,1400 Btu anat l=BsR MN? net rating qft water Trade Price with standard equipment hush leefcet deluxe Jacket chimney sixe diameter height Inches feet approx. shiDoinr weight Packaged boilers without tankless heater G-23-*P G-24-*P G-25-*P G-26-*P G-27*P 60 90 120 150 180 48 72 96 120 144 36 240 $271.00 $285.00 4 20 315 54 360 328.00 342.00 5 20 375 72 480 372.00 386.00 6 20 455 90 600 413.00 427.00 6 20 540 108 720 449.00 463.00 6 20 630 Packaged boilers with factory installed tankless heater G-24-*PT 90 72 218 2V4 54 360 $361.00 $375.00 5 20 390 G-25*PT 120 96 222 3 72 480 407.00 421.00 6 20 470 G-26*PT 150 120 222 3V4 90 600 448.00 462.00 6 20 550 G-27-*PT 180 144 222 3>/2 108 720 484.00 498.00 6 20 642 AGsllons of water per minute heeled from 40F to 140F with 200F boiler water temperature. *Substitute letter "F" for flush or *`0*` for deluxe jacket. Standard equipment all boilers: (see options, page 9) V-600 combination diaphragm gas valve furnished for Natural, Manufactured. Mixed, LP-Air, and LP gas boilers. V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch.. Manual shut-off valve; Pilot cock; Pilot filter (for manufactured gas and S.U.R.); Boiler drain; Draft hood; Insulated jacket; Transformer; ASME relief valve (30 lbs.); Theraltimeter (30 lbs.); Wiring Harness; 1 y<" circulator with piping. Controls regularly furnished are for 115 volt, 60 cycle current. Additional standard equipment for boilers with heater: Tankless heater as listed above. RS-116-F combination immersion control (high and low limits, circulator operation, transformer and built-in relay), CA-520 thermostat. Additional standard equipment for boilers less heater: CA-520 thermostat, combination immersion high limit and reverse acting control. Left hand end section without tankless heater opening. Note: Packaged boilers are shipped with jacket, all controls (except thermostat), cir culator and piping, mam burners and manifold controls and piping factory installed and wired. CA-520 thermostat, manual shut-off valve and relief valve shipped fastened inside boiler crate. Draft hood shipped in separate carton for flush jacketed boiler and G-23-DP. Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. For ordering instructions for gas boilers, see page 15. i For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 3 04532 HH-2 PACKAGED BOILERS GAS FIRED warn American-^Standard HYDRONIC HEATING PACKAGED G-2 "FPB"AMERiCAN-<$tandard GAS BOILERS VI lUlUtM----WJ / 1IM1U._H__WfI-U-aalW___tS_WJ Designed and equipped with controls lor forced circulation. Factory assembled and crated. Flush Jacket only. "Eliminaire" (cast-in air eliminator in left end section). WATER ONLY paclcagod bolter numbor G23-FPB G-24-FPB G-25FPB G-26-FPB G-27-FPB A.OJL input Mbh 60 90 120 150 180 A.QJL output Mbh 48 72 96 120 144 not IsBsft rating Mbh 36 54 72 90 108 not. rating sq.ft watar 240 360 480 600 720 Trado frteo with qulpmnt $255.00 283.00 319.00 394.00 431.00 chimnoy also dlamotor Inchoa 4 5 6 6 6 holght foot 20 20 20 20 20 approx. shipping might 317 377 457 542 632 Standard equipment all boilers: V-600 combination diaphragm gas valve furnished with Natural. Manufac tured. Mixed gas boilers. V-600 features built-in gas pressure regulator and thermocouple type safety pilot switch. Manual shut-off valve; Pilot cock; Pilot filter (for manufactured gas and S.U.R.); Boiler drain; Draft hood; Insulated jacket; Transformer; ASME relief valve (30 lbs.); Theraltimeter (30 lbs.); Wiring Harness; lYt" circulator. CB-S80 thermostat, CA-655 immersion limit control. Left hand end section without tankless heater opening. Controls regularly furnished are for 115 voit, 60 cycle current. Not*: Packaged boilers are shipped with jacket, all controls (except thermo stat) . circulator, main burners and manifold controls and piping factory in stalled and wired. CA-580 thermostat, manual shut-off valve and relief valve shipped fastened inside boiler crate. Draft hood shipped in separate carton. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of i% for each 1,000 feet above sea level. For ordering instructions for gas boilers, see page 15. Optional Equipment: (only those below available) Runner Type Pilot Ignition for use with listed gases furnished at no charge when specified on order to meet local utility codes. Floor Shield for Combustible Flooring. Add suffix letter "C" to boiler num ber and add 53.00 to Trade Price of boiler. Pilot Filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes. Manual Opening Feature on V-600 gas valve furnished at no additional when specified on order to meet local utility codes. Zone Control Valve Sets available for water boilers, for details and prices, see page 30. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-2 Pag* 4 04533 American-^Standard H Y DRONIC HEATING PACKAGED BOILERS GAS FIRED WATH PACKAGED ALL-PURPOSE 2-2 ArERiCAK'<vlsnuai u GAS BOILERS Designed for forced or gravity circulation. Factory assembled and crated. Deluxe Jacket. Sections tested for 30 lbs. water working pressure. "Eliminalre" (cast-in air eliminator in left end section) WATER ONLY packaged boiler number G-23-DPG G-24-DPG G-25-DPG G-26-DPG G-27DPG A-GJL Input Mbh A.(LA. output Mbh Mfd,, Nat. Mixed and LP Qa* LP-AIrGas $25-1400 Stu net t = Bs=R rating Mbh 60 48 36 90 72 54 120 96 72 150 120 90 180 144 108 net rating 4 It water 240 360 480 600 720 Trade Price with standard equipment chimney fixe diameter inches height feet $208.50 4 20 265.50 5 20 309.50 6 20 350.50 6 20 386.50 6 20 approx. shipping weight 317 377 457 542 632 Standard equipment: (see options, page 9) V-600 combination diaphragm gas valve furnished for all gases. V-600 fea tures built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); boiler drain; draft hood; insulated jacket; transformer. Water only: Theraltimeter; ASME relief valve; CA-655 immersion limit control. Controls regularly furnished are for 115 volt, 60 cycle current Room thermostat not included in above prices. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For elevations above 2.000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet, above sea level. For ordering instructions for gas boilers, see page 15. For complete information on ratings, see page 2. For discount on repairs, see page 2. Page 5 04534 HH-2 BOILERS--GAS FIRED WATtl American-Standard HYDRONIC HEATING G-2 AMERiCAN-^tandard GAS BOILERS Desigued for iorced circuiation. Flush or Deluxe jacket. Factory Assembled Sections, tested for 30 lbs. water working pressure. "Eliminaire" (cast-in air eliminator in left end section) WATER ONLY A.GA. input Mbh A.GJL tanklest output haatar Mbh numbar A l=W=H rating Mfd.. NaU Mixed and LP Gaa; LP-Air Gat 525-1400 Btu net l=B=R rating Mbh net rating q ft water Boilers without tankless heater section G-23-* G 24-* G-25-* G 26-* G27-* G-28-* G-29-* G-210-* G-211-* 60 90 120 150 180 210 240 270 300 48 72 96 120 144 168 192 216 240 36 240 54 360 72 480 90 600 108 720 126 840 144 960 162 1080 180 1200 Trada Prica with standard equipment flush jacket deluxe jacket chimney size diameter height inches feet approx. shipping weight $187.00 $201.00 4 20 275 244.00 258.00 5 20 351 288.00 302.00 6 20 426 329.00 343.00 6 20 488 365.00 379.00 6 20 551 407.00 421.00 7 20 627 449.00 463.00 7 20 695 480.00 494.00 7 20 759 526.00 540.00 7 20 839 Boilers with factory installed tankless heater G-24-T 90 72 218 2 Vi 54 360 $285.00 $299.00 5 20 363 G-25-T 120 96 222 3 72 480 331.00 345.00 6 20 438 G-26--T 150 120 222 3 Vi 90 600 372.00 386.00 6 20 498 G-27--T 180 144 222 3/2 108 720 408.00 422.00 6 20 562 G-28--T 210 168 222 3*/2 126 840 450.00 464.00 7 20 640 G-29--T 240 192 222 3>/j 144 960 492.00 506.00 7 20 708 G-210--T 270 216 222 3 V2 162 1080 523.00 537.00 7 20 774 G-211--T 300 240 222 3 V2 180 1200 569.00 583.00 7 20 857 Gallons of water per minute heated from 40F to 140F with 200F boiler water temperature. `Substitute letter "F" for flush or `'O'* for deluxe jacket. Boiler with flush jacket and tankless heater Standard equipment all boilers: (see options, page 9) V-600 combination diaphragm gas valve furnished with G-23 through G-29 Natural. Mixed, LP-Air, LP gas boilers and G-23 through G-27 Manufactured gas boilers. V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. V-532 diaphragm gas valve furnished for all gases for sizes not listed above with separate gas pressure regulator (except LP) and Baso switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); Boiler drain; draft hood; insulated jacket; transformer; theraltimeter (30 lbs.); ASME relief valve (30 lbs.). Additional standard equipment, boilers less heater: CA-655 immersion limit control. Left hand end section without tankless heater opening. Additional standard equipment, boilers with heater: Tankless heater as listed above. Note: tankless heater is installed at factory in section assembly. RS-116F combination immersion control (high and low limits, circulator operation, transformer and built-in relay). Controls regularly furnished are for 115 volt, 60 cycle current. Room thermostat not included in above prices. Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2.000 feet, ratings should be reduced at the rate of 4% for each 1.000 feet above sea level. For ordering instructions for gas boilers, see page 15. a For complete information on ratings, see page 2. For discount on repairs, see page 2. hh 2 Page 6 04535 American-Standard HYDRONIC HEATING BOILERS--GAS FIRED STEAM and WATER G-2 ALL-PURPCSE AMERICAS-c$Udard GAS BO ikcfia Designed for water (forced or gravity) or steam. Flush or Deluxe jacket. Factory Assembled Sections. Sections tested for 30 lbs. water working pressure. "Eliminaire" (cast-in air eliminator in left end sectionl STEAM ONLY boiler number A.G.A. input Mbh A.GJL. output Mbh Mfd,, Nat., Mixed end LP Gee; LPAIr Gee S2S-140Q Btu G-23-*G G-24-*G G-25-*G G-26-*G G-27-*G G-28-*G G-29 *G G-210'G G-211-*G 60 90 120 150 180 210 240 270 300 48 72 96 120 144 168 192 216 240 net IsBsR retinf Mbh 36 54 72 90 108 126 144 162 180 eq ft 150 225 300 375 450 525 600 675 750 Trede Price with etenderd equipment flueh jacket deluxe Jecket $224.00 281.00 325.00 366.00 402.00 444.00 486.00 517.00 563.00 $238.00 295.00 339.00 380.00 416.00 458.00 500.00 531.00 577.00 chimney elze dlemeter inches 4 5 6 6 6 7 7 7 7 height feet 20 20 20 20 20 20 20 20 20 epprox. hipping weight 287 363 438 500 563 639 707 771 851 WATER ONLY boiler number A.GJt. input Mbh A.GJL output Mbh Mfd., Nat., Mixed and LP Gee; LP-Air Gee 525-1400 Btu net l=B=R rating Mbh net rating q ft water G-23*G G-24-*G G 25-'G G-26-G G-27-*G G-28'G G-29-'G G-210-*G G-211 *G 60 90 120 150 180 210 240 270 300 48 72 96 120 144 168 192 216 240 36 54 72 90 108 126 144 162 180 240 360 480 600 720 840 960 1080 1200 'Substitute letter for flush or "D" for deluxe jacket. Trade Price with etenderd equipment flueh jacket deluxe jecket $187.00 244.00 288.00 329.00 365.00 407.00 449.00 480.00 526.00 $201.00 258.00 302.00 343.00 379.00 421.00 463.00 494.00 540.00 chimney size diameter inches height feet 4 20 5 20 6 20 6 20 6 20 7 20 7 20 7 20 7 20 approx. shipping weight 277 353 428 490 553 629 697 761 841 Standard equipment: (see options, page 9) V-600 combination diaphragm gas valve furnished with G-23 through G-29 Natural, Mixed, LP-Air. LP gas boilers and G-23 through G-27 Manufac tured gas boilers. V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. V-532 diaphragm gas valve furnished for all gases for sizes not listed above with separate gas pressure regulator (except LP) and Baso switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); boiler drain; draft hood; insulated jacket; transformer. Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; external resetting low water cut-off. Water only: Theraltimeter; ASME relief valve; CA-655 immersion limit control Controls regularly furnished are for 115 volt, 60 cycle current. Room thermostat not included in above prices. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For altitudes above 2.000 feet, ratings should be reduced at the rate of 49e for each 1,000 feet above sea level. For ordering instructions for gas boilers, see page 15. For complete information on ratings, see page 2 For discount on repairs, see page 2. Page 7 04536 HH-2 BOILERS--GAS FIRED WATTB AND ST1AM AMERicAx-^taitdard HYDRONIC HEATING G-2 ALL-PURPOSE American-Standard GAS BOILER FOR USE WITH "DW" EQUIPMENT DIRECT TYPE -- Water boilers for hot water supply Flush or Deluxe jacket. Hydrostatically tested at 200 lbs. Working pressure 80 lbs. Not recommended for use in hard water areas. boiler number A.GJL. input Mbh A.G.A. rating--ffjllon* weter per hour output Mbh 60* rite 80* rite 100* rite Mfd^ Nat, Mixed end LP Get; LP-AJr Get 525*1400 Btu Trede Price with 'DW' equipment flush Jacket deluxe Jacket approx. shipping weight G-23*G G-24-*G G-25-*G G-26-*G G-27-*G G-28-*G G-29*G G-210-*G G-211-*G 60 90 120 150 180 210 240 270 300 48 72 96 120 144 168 192 216 240 96 144 192 240 288 336 384 432 480 72 108 144 180 216 252 288 324 360 58 86 115 144 173 201 230 260 288 $201.00 258.00 302.00 343.00 379.00 421.00 463.00 494.00 540.00 $215.00 272.00 316.00 357.00 393.00 435.00 477.00 508.00 554.00 277 353 428 490 553 629 697 761 841 'Substitute tetter '*F'* for flush or *'0*' for deluxe jacket. "DW" standard equipment: (see options, page 9) In addition to boiler for water with "standard equipment" page 7, "DW" boilers are furnished with Ther-pressure-meter instead of Theraltimeter; 80 lb. ASME relief valve instead of 30 lb. valve; CA-666 immersion operating control for use in storage tank; tank thermometer; name and rating plate for 80 lbs. working pressure. For ordering instructions for gas boilers, see page IS. Controls regularly furnished are for 115 volt, 60 cycle current. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. FOR USE WITH "IS" EQUIPMENT INDIRECT TYPE --Sfeom boilers for hot water supply Flush or Deluxe jacket. boiler number A.CLA. input Mbh A.GJt. ratlng-gallont water per hour output Mbh 60* rite 80* rite 100* rite Mfd,, Nat,, Mixed end LP Gat; LP*Air Get 525-1400 Btu Trade Price with "IS" equipment fluth lacket deluxe lacket approx. thipping weight G-23*G G-24*G G-25-*G G-26-*G G-27-*G G-28-*G G-29-*G G-210-*Q G-211-*G| 60 90 120 150 180 210 240 270 300 48 72 96 120 144 168 192 216 240 96 144 192 240 288 336 384 432 480 71 107 143 179 215 251 287 323 359 58 86 115 144 173 201 230 259 288 $234.00 291.00 335.00 376.00 412.00 454.00 496.00 527.00 573.00 $248.00 305.00 349.00 390.00 426.00 468.00 510.00 541.00 587.00 287 363 438 500 563 639 707 771 851 `Substitute letter "F*' for flush or "D" for deluxe jacket. "IS" standard equipment: (see options, page 9) In addition to boiler for steam with "standard equipment'' page 7, "IS" boilers are furnished with CA-666 immersion operating control for use in storage tank. For ordering instructions for gas boilers, see page 15. Controls regularly furnished are for 115 volt, 60 cycle current. Ratings shown are for installations at sea level and at elevations up to 2,000 feet For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. For discount on repairs, see page 2. HH-2 Page 8 04537 AMERiCAx-iStandard HYDRONIC HEATING BOILERS--GAS FIRED WATER G-2 OPTIONAL EQUIPMENT ALL BOILERS (Pages 3 thru S except "Fhb'- Page 4): Runner type pilot ignition for use with listed gases furnished at no charge when specified on order to meet local Utility codes. Push button electric ignition for use with listed gases Not available with self-energizing controls. Specify on order and add S11.85 to Trade Price of boiler Floor shield for combustible flooring. Add suffix letter "C" to boiler number and add $3.00 to Trade Price of boiler. Pilot filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes. Manual opening feature on V-600 or V-532 gas valves fur nished at no additional charge when specified on order to meet local utility codes. Zone control valve sets available for water boilers, for details and prices, see page 30. PACKAGED GAS BOILERS (Page 3 only): only those options listed above applicable to these boilers. GAS BOILERS (Page 6 only) for forced circulation: Tankless heaters No. 226 or 232; available factory installed in place of No. 222, but limited to certain boiler sizes. See table below for I=W=H ratings and applicable boiler size. If desired, specify on order and add to Trade Price of boiler with tankless heater the following charges: Heater No. Added Charge 226 ...................................................................... $ 8.00 232 ...................................................................... 12.00 Dual-gas boilers: available for both natural and propane gases. See below for added charges to boiler prices on Page 6. boiler no. added charge boiler no. added cherge G-23 G-24 G-25 G-26 G-27 $50.00 52.00 54.00 56.00 58.00 G-28 G 29 G-210 G-211 $60.00 62.00 64.00 66.00 Equipment includes in addition to standard trim two V-532 gas valves, two manifolds with spuds factory assembled, outdoor changeover control. Room thermostat prices shown on page 32. PACKAGED ALL-PURPOSE BOILERS (Page 5 only): Tankless heaters: when boilers (5 thru 7 section) are to be used for forced circulation I=W = H tankless heaters can be installed in opening used for gravity tapping flange cover, but limited to certain boiler sizes. See table below for I=W=H ratings and applicable boiler size Tankless heaters can be ordered shipped separately at following prices: Heater No. Trade Price 222 ........................................................ $21.00 226 ..................................................................... 29.00 Self-energizing controls (consists of special gas valve, pilot burner, limit control) for mfd., natural and mixed gas, avail able when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 32. Room thermostat prices shown on page 32. ALL-PURPOSE BOILERS (Page 7 only): WATER BOILERS ONLY: Tankless heaters: when boilers (5 thru 11 section) are to be used for forced circulation I = W = H tankless heaters can be installed in opening used for gravity tapping flange cover, but limited to certain boiler sizes. See table below for I=W=H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately at following prices: Heater No. Trede Price 222 ............................................................. $21.00 226 .......................................................................... 29.00 232 .......................................................................... 33.00 STEAM BOILERS ONLY: McDonnell-Miller No. 101-24V Electric Water Feeder can be added to the No. 67 Low Water Cut-off furnished with G-2 All-Purpose Steam Boilers to provide Low Water Cut-off and Feeder Combination. If desired specify on order and add $34.57 to Trade Price of Steam Boiler. Side Outlet Pop Valve may be substituted at no additional charge if specified on order to meet local code requirements. WATER OR STEAM BOILERS: Dual-gas boilers: available for natural and propane gas. see added charges shown under "GAS BOILERS (Page 6 only) ." Self-energizing controls (consists of special gas valve, pilot burner, limit control, low water cut:off for steam boilers) for mfd., nat. and mixed gas, available when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 32. Room thermostat prices shown on page 32. G-2 Tankless Heaters boiler number A.G.A. input Btu/hr. heater A 218 Rating o heater a 222 heater A 226 heater A 232 G-24 G-25 G-26 G-27 G-28 G-29 G-210 G-211 90,000 120,000 150.000 180,000 210,000 240,000 270,000 300,000 2 Vi -- -- -- --3 ---- -- 3V4 -- -- -- 3 Vi 4 -- -- 3 Vi 4 Vi -- -- 3 Vi 4 Vi 4 Vi -- 3>/z 4 Vi 4 Vi -- 3 Vi 4 Vi 5 Heaters have been tested with G-2 boilers and are available only factory installed in all models m the above sizes except for the all purpose boiler*. e Gallons water per minute heated from 40*F to 140*F with 200*F boder water temperature. Last two digits designate lineal feet of Tru Fin tubing in heater cod. Page 9 04538 Hh 2 B01URS-GAS FIRED SHAM AMO WATKt STEAM ONLY belter umber 6-403 6-404 6-405 6406 6-407 6-408 6-409 64010 WATER ONLY belter 6403 6404 6405 6406 6407 6408 6409 64010 STEAM ONLY bolter amber 6403 6404 6405 6406 6407 6408 6409 64010 WATER ONLY bolter auwtiaj 6403 6404 6405 6406 6407 6408 6409 64010 A.CJL lapt Utah 150 225 300 375 450 525 600 675 1CJL tagst MM 150 225 300 375 450 525 600 675 A.G.A. Input Mbb 120 180 240 300 360 420 480 540 A.6X lopot Mbb 120 180 240 300 360 420 480 540 HYDRONIC HEATING 0-40 AMERiCAN'<$tandard OA8 BOILERS For Built-In Water Heater Arrangement, ee page ' * Deluxe Jacket Tested and equipped tor 50 lbs. water wining "Eliminaire" (cast-in air eliminator In left end see on . FOR NATURAL, MFD., MIXED, OASES ONLY A.GJL natpat Mbit 120 180 240 300 360 420' 480 540 OOt Is* Ul rating Mbb 90.0 135.0 180.0 225.1 270.1 315.1 360.1 405.1 sq. ft 375 563 750 938 1125 1313 1500 1688 irada ffka with itaadari $380 00 477.00 577.00 697.00 787.00 887.00 907.00 1057.00 chimney tixe diem. iiicM* hi ft. 6 20 7 20 7 20 8 20 8 20 9 20 10 20 10 20 approx. weight 858 1027 1195 1370 1544 1713 1880 2050 A.CJL fltpBt Mbb Mt lalsR nti*f Mbb rating tg. ft water 120 90.0 600 180 135.0 900 240 180.0 1200 300 225.1 1500 360 270.1 1800 420 315.1 2100 480 360.1 2400 540 405.1 2700 FOR LP AND LP-AIR A.6.A. ootpot nit 1= B=P rating Mbb Mbb sq. ft 96 72.0 300 144 108.0 450 192 144.0 600 240 180.0 750 288 216.1 900 336 252.1 1050 384 288.1 1200 432 324.1 1350 Train Wte wit* standard aalaaiaaf chlmnoy tilt diem. IbcMk ht It. $34.1.00 6 20 440.00 7 20 540.00 7 20 600 00 8 20 750 00 8 20 850 00 9 20 910 00 10 20 1070 00 10 20 GAS ONLY Trad# Prleo wit* chimney size diam. inches ht. ft. $380.00 6 20 47/ 00 7 20 577 00 7 20 697.00 8 20 787.00 8 20 887.00 9 20 q|i/ 00 10 20 1057 00 10 20 epprex. skipping weight 827 998 1162 1349 1517 1686 1856 2026 approx. shipping weight 858 1027 1195 1370 1544 1713 1880 2050 A.6JL ootpot Mbb 96 144 192 240 288 336 384 432 Oft i=e=* ratine Mbb not rating aq. ft waitr Traaa Prka With itetfartf t0iipo,*B* chimney size dlan. Inchat ht. ft. approx. shipping weight 72.0 108.0 144.0 180.0 216.1 252.1 288.1 324.1 480 720 960 1200 1440 1680 1920 2160 ^ $34100 440.00 54000 600 00 750 00 880 00 980 00 1070.00 6 7 7 8 8 9 10 10 20 20 20 20 20 20 20 20 827 998 1162 1349 1517 1686 1856 2026 Standard equipment include.! (see options, pages 11 and 15) Baso* ombiMtion^ilot switch* and valve with auxiliary Base pilot.valves Optional other gases at no additional charge-. manual shut-off valve; pilot filter (mfd gas and SUR); gas pressure regulator (except for LP gas); boiler drains and pilot cocks, insulated jacket; draft hood; water heater opening cover plates. Iteam |?ijge; ASME safety valve: 4.V-BA-1 boiler pressure limit control; gauge glass with trimmings; external resetting lew w'ater out-off. TTieraUimeter; ASME relief valve for SO lbs.; CA-655 immersion limit control. Controls regularly furnished are for US volt, 60 cycle current. Ratings shown are for installations at sea level nd at elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. Room thermostat not included in above prices. For complete information on optional equipment, see pages 11 and 15. For ordering instructions for gas boilers, see page 15. i For complete information on boiler ratings, see page 2. For discount on repairs. >ee page 2. Pag* 10 04539 HYDRONIC HEATING BOILERS-GAS FIRED STEAM ANO WATER G-40 OPTIONAL EQUIPMENT BOILERS WITH TANKLESS HEATERS: water {for forced circulation) and steam boilers can be furnished with tankless heaters. Some heaters are limited to certain boiler sizes as shown in ratings table below. Tsnkless heaters with controls for water boilers: RS-116-F packed in trim box in place of CA-655 for standard equipment. Tankless heaters with controls for steam boilers: additional CA-666 immersion operating control packed in trim box. If tankless heaters with controls are desired, specify on order with boiler and add to Trade Price of boiler with standard equipment the following charges. Tankless heaters less controls will be furnished when specified at the Trade Prices shown below for heaters only. HEATER HO. 218 222 226 232 445 HEATER WITH CONTROLS Water Steam $43.00 45.00 53.00 57.00 74 00 $29.00 31.00 39.00 43.00 60.00 HEATER ONLY Water er Steam $19.00 21.00 29.00 33.00 50.00 Water flow regulators sized for tankless heater involved will be fur nished with heater when specified on order to meet local Utility require ment at S2.00 Trade Price additional charge per heater. Factory assembled sections: G-403 through G-406 can be shipped with sections factory assembled when specified on order. If desired less tankless heater, add $15.00 to Trade Price of boiler. If desired with fac tory installed tankless heater, specify heater number, and add $15.00 plus price of heater to Trade Price of boiler. Dual Gas Equipment: available with steam or water boilers for use with Natural and Propane gases only, in addition to standard trim, dual gas equipment includes tube withm a tube manifold, two V-532 gas valves, gas pressure regulator (natural gas only), two manual shut off valves, ribbon burners, 100% shut-off (consists of Baso combination pilot valve and switch with auxiliary Baso pilot valves), pilot cock, outdoor thermostatic adjustable changeover control. Boiler selection should be based on the A.G.A. and l=B=R ratings shown for LP gas. If desired specify on order and add to Trade Price of boiler with standard trim the following charge: Boiler Number G-403 G-404 G-405 G-406 Add to Boiler Trade Price $60.00 62.00 64.00 66.00 Boiler Number G-407 G-408 G-409 G-4010 Add to Roller Trade Price $68.00 70.00 72.00 74.00 Electronic Control Systems: available with steam or water boilers. If desired refer to page 15 for complete details and additional Trade Price charges. Tri-cock tappings and valves: if desired for steam boilers to meet local code specify on order and add $4.00 to Trade Price of steam boiler. Seif-energizing controls: available for steam or water (gravity) (ess tankless heater for natural and mixed gases only. Equipment includes special gas valve, pilot burner, limit control, low water cut-off for steam boilers. Furnished at no additional charge when specified on order Special room thermostat required, for Trade Price see Page 32. McDonnell-Miller No. 101-24 Volt Electric Water Feeder can be added to No. 67-GAR low water cut-off furnished with G-40 Steam Boilers to provide low water cut off and feeder combination, if desired specify on order and add $34.57 to Trade Price of steam boiler. McDonnell-Miller No. 47-2 low water cut-off and feeder combination may be specified in place of regularly furnished No. 67-GAR for steam boilers. If desired specify on order and add $33.00 to Trade Price of steam boiler. McOonnefl-Milier No. 247-2 low water cut-off and feeder combination for water boilers is available with G-40 Water Gas Boilers when specified on order. Add to the Trade Price of the water boiler with regular equipment the current Trade Price of this item shown in the current McDonnell-Miller Price Sheet. Runner type pilot ignition: all sizes of G-4Q are available with Runner type pilot ignition for mfd.. nat- and mixed gas non-100% shut-off at no additional charge when specified on order to meet local Utility codes. Push button electric ignition: all sizes of G-40 are available with push button electric ignition for use with mfd., nat. and mixed gas non-100% shut-off and will be furnished when specified on order at $11.65 added charge. Pilot filters for G-40 for natural and mixed gases available at no addi tionai charge when specified on order to meet local utility codes. Room thermostats available at Trade Prices shown on Page 32. "IS" Equipment: G-40 Gas Boilers can be furnished for use with In direct Steam Hot Water Supply systems. CA-666 immersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on Page 32. V-532 Diaphragm Gas Valve without manual opening may be substi tuted for V-531 Gas Valve with manual opening at no additional charge, if desired, specify on order. Side Outlet Steam Pop Valves may be substituted at no additional charge if specified on order to meet local code requirements. Jacket Extension: covers all controls on left end of boiler. If desired, specify on order and add $25.00 to Trade Price of Boiler. G-40 Tankless Heater Ratings (Gallons per minute9) Boiler G-403 G-404 G-403 G-408 G-407 G-408 G-409 6-4010 HEATER 218 Steam Water 34 3tt 4 31* 4 3 >* 4 3Vj 4 3Vfc 4 3** 4 3V* 4 HEATER 222 Steam __ 4 4 4 4 4 4 4 Water _ 4Ut 4<* 4Va 4i* 4Vz 4i* HEATER 226 Steam Water ---- ---- 5Vi 6 5>* 6 6 6Va 6 61* 6 61* 6 6i* HEATER 232 Steam _ -- -- -- 7 71* 71* 71* Water _ -- -- -- 7i* 8 8 8 HEATER 445 Steam Water ---- ---- ---- ---- ---- 8V5 9 81* 9 81* 9 *Gallont of water pr m/nufa railed from 40F. fo I40QF. Lori fwo digift of heater number* indicofe lineal feaf of Tru-fin tubing in haofer coil. Page 11 HH 2 04540 jAMEWCAJi*<$tandard HYDRONIC HE ATI NO G-60 AMERiCAN-fStandard GAS BOILER for Natural, Mixed, Manufactured Gates Jacketed. Tested end equipped for 50 lbe. water working pressure. Available tor 80 lbs. working pressure on special order. boiler number G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041 WATER ONLY A.O. input Mbh 725 870 1015 1160 1305 1450 1740 2030 2320 2610 2900 3045 3480 3915 4350 4640 5220 5800 A.O. output Mbh 580 696 812 928 1044 1160 1392 1624 1856 2088 2320 2436 2784 3132 3480 3712 4176 4640 not 1= 5=R ratine Mbh sq ft 435.1 522.1 609.2 696.2 783.2 870.2 1054.5 1248.3 1438.8 1621.1 1801.2 1891.3 2161.5 2430.1 2701.9 2880.4 3245.3 3602.5 1813 2176 2538 2901 3263 3626 4394 5201 5995 6755 7505 7880 9006 10126 11258 12002 13522 15010 Trade Price with standard equipment $ 998.00 1155.00 1320.00 1498.00 1675.00 1820.00 2129.00 2445.00 2748.00 3057.00 3366.00 3570.00 4004.00 4333.00 4932.00 5221.00 5840.00 6458.00 chimney size diem. in. ht ft ii 20 12 20 13 20 13 20 14 20 15 20 15 20 16 20 16 30 17 30 18 30 19 30 20 30 21 30 22 30 24 30 26 30 26 30 approx* shipping weight 2751 3151 3537 3934 4346 4739 6069 6855 7640 8523 9312 10154 11361 12648 13841 15068 16720 18346 boiler number G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041 A.G.A. input Mbh 725 870 1015 1160 1305 1450 1740 2030 2320 2610 2900 3045 3480 3915 4350 4640 5220 5800 A.G.A. output Mbh 580 696 812 928 1044 1160 1392 1624 1856 2088 2320 2436 2784 3132 3480 3712 4176 4640 net l=B=R rating Mbh 435.1 522.1 609.2 696.2 783.2 870.2 1054.5 1248.3 1438.8 1621.1 1801.2 1891.3 2161.5 2430.1 2701.9 2880.4 3245.3 3602.5 net rating sq ft water 2900 3480 4060 4640 5220 5800 7030 8320 9590 10805 12010 12610 14410 16200 18010 19205 21635 24015 Trade Price with standard equipment $ 961.00 1118.00 1283.00 1461.00 1638.00 1783.00 2092.00 2408.00 2711.00 3020.00 3329.00 3533.00 3967.00 4296.00 4895.00 5184.00 5803.00 6421.00 chimney size diam. In* ht ft a 20 12 20 13 20 13 20 14 20 15 20 15 20 16 20 16 30 17 30 18 30 19 30 20 30 21 30 22 30 24 30 26 30 26 30 approx. shipping weight 2741 3141 3527 3923 4335 4728 6049 6835 7620 8503 9292 10139 11334 12616 13809 15036 16690 18316 Standard equipment includes: (see options, pages 14 and 15) V-531 diaphragm gas valve with manual opening feature; Baso automatic pilot switch for non-100% shut-off (100% shut-off controls consisting of Baso combination pilot switch and valve with auxiliary Baso pilot valves, optional at no additional charge); manual shut-off valve; pilot filter (mfd gas and SUR); gas pressure regulator; boiler drains and pilot cocks; insulated jacket; draft hood. Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; resetting low water cut-off. Water only: Theraltimeter and ASME relief valve for 50 lbs.; CA-655 immersion limit control. Controls regularly furnished are for 115 volt. 60 cycle current. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. Room thermostat not included in above prices. For complete information on optional equipment, see pages 14 and 15. For ordering instructions for gas boilers, see page 15. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-2 Pag* 12 04541 Ame rican Standard HYDRONIC HEATING BOILERS--GAS FIRED ITtAM AMD WATIK G-60 AMERiCAN-<$tandard GAS BOILER for LP and LP-Air Gas only Jacketed. Tested and equipped for 50 lbs. water working pressure. Available for 80 lbs. working pressure on special order. STEAM ONLY beiler number G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G 6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041 WATER ONLY boiler number G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041 A.G.A. input Mbh 650 780 910 1040 1170 1300 1560 1820 2080 2340 2600 2730 3120 3510 3900 4160 4680 5200 A.G.A. input Mbh 650 780 910 1040 1170 1300 1560 1820 2080 2340 2600 2730 3120 3510 3900 4160 4680 5200 A.G.A. output Mbh 520 624 728 832 936 1040 1248 1456 1664 1872 2080 2184 2496 2808 3120 3328 3744 4160 A.G.A. output Mbh 520 624 728 832 936 1040 1248 1456 1664 1872 2080 2184 2496 2808 3120 3328 3744 4160 not l=B sR rating Mbh 390.1 468'. 54C 624.2 702.2 780.2 936.2 1108.1 1282.0 1452.3 1614.9 1695.7 1937.9 2180.1 2422.4 2585.4 2903.7 3229.8 sq. ft 1625 1950 2276 2601 2926 3251 3901 4617 5342 6051 6729 7065 8075 9084 10093 10773 12099 13458 net l=B=R rating Mbh 390.1 468.1 546.1 624.2 702.2 780.2 936.2 1108.1 1282.0 1452.3 1614.9 1695.7 1937.9 2180.1 2422.4 2585.4 2903.7 3229.8 net rating q. ft. water 2600 3120 3640 4160 4680 5200 6240 7385 8545 9680 10765 11305 12920 14535 16150 17235 19360 21530 Trade Price with otandard equipment $ 998.00 1155.00 1320.00 1498.00 1675.00 1820.00 2129.00 2445.00 2748.00 3057.00 3366.00 3570.00 4004.00 4333.00 4932.00 5221.00 5840.00 6458.00 chimney *lie dlam. in. ht. ft. ii 20 12 20 13 20 13 20 14 20 15 20 15 20 16 20 16 30 17 30 18 30 19 30 20 30 21 30 22 30 24 30 26 30 26 30 Trade Price with etandard equipment $ 961.00 1118.00 1283.00 1461.00 1638.00 1783.00 2092.00 2408.00 2711.00 3020.00 3329.00 3533.00 3967.00 4296.00 4895.00 5184.00 5803.00 6421.00 chimney size diam. In. ht. ft. ii 12 13 13 14 15 15 16 16 17 18 19 20 21 22 24 26 ` 26 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30 "* approx. chipping weight 2751 3151 3537 3934 4346 4739 6069 6855 7640 8523 9312 10154 11361 12648 13841 15068 16720 18346 2741 3141 3527 3923 4335 4728 6049 6835 7620 8503 9292 10139 11334 12616 13809 15036 16690 18316 i a la l* Standard equipment includes: (see options, pages 14 and 15) V-531 diaphragm gas valve with manual opening; 100% shut-off <100% shut-off controls tor LP-air and LP gases consists of Baso combination pilot switch and valve with auxiliary Baso pilot valves); manual shut-off valve; gas pressure regulator (except for LP-gas); boiler drains and pilot cocks; insulated jacket; draft hood. Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; resetting low water cut-off. Water only: Theraltimeter and ASME relief valve for 50 lbs.; CA-655 immersion limit control. Controls regularly furnished are for 115 volt, 60 cycle current. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For eleva tions above 2.000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. Room thermostat not included in above prices. For complete information on optional equipment, see pages 14 and 15. For ordering instructions for gas boilers, see page 15. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 13 04542 HH-2 BOILERS--GAS FIRED WATtft AND ftTiAM American-Standard HYDRONIC HEATING G-60 OPTIONAL EQUIPMENT Push button electric ignition: aii size* ul G-60 are avaiiaoic with push button electric ignition for use with mfd., nat. and mixed gas non-100'/* shut-off. and will be furnished when specified on order at the following added charges: boiler size G-606 thru G-6011 added charge $11.85 G-6013 thru G-6021 23.70 G-6022 thru G 6031 35.55 G-6033 thru G-6041 47.40 Pilot filters for G-60 for natural and mixed gases available at no additional charge when specified on order to meet local utility codes. Room thermostats available at Trade Prices shown on page 32. McDonnell-Miiler Low Water Cut-off No. 67-AR external type can be substituted for the regular No. 69 Low Water Cut-ofT on G-60 steam gas boilers at no additional charge. If desired, specify on order. "IS" Equipment: G-60 gas boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. CA-666 im mersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as showrt on page 32. This control operates gas valves on boiler electrically as required Shipping weights of gas boilers for hot water supply are same as shown for regular gas boilers. Tri-cock tappings and valves; if desired for steam boiler to meet local code specify on order and add $4.00 to Trade Price of steam boiler. G-60 available tested at 80 lbs. water working pressure when specified on order. Add $3 00 per section to Trade Price of water boiler. McDonneii-tf iiier No. 47*2 and 51*2 Luw VVaier Cui-oii omj Feeder combinations are available with G-60 steam gas boil ers in place of regularly furnished No. 69 low water cut-off. when specified on order, at the following added charges to Trade Price of steam boilers with regular equipment: boiler number G 606 thru G-6011 G-6013 thru G-6041 combination number 47-2 51 2 added charges $33.00 46.00 McDonnell-Miller No. 247*2 and 51*2 low water Cut-off and Feeder combinations for water boilers are available with G-60 water gas boilers when specified on order. Add to the Trade Price of the water boiler with regular equipment the current Trade Price for these items shown in the current McDonncllMiller price sheet. V-532 Diaphragm gas valve without manual opening may be substituted for V-531 Gas valve with manual opening at no additional charge. If desired specify on order. Side Outlet Steam Pop Valves may be substituted at no addi tional charge if specified on order to meet local code require ments. G-60 external water heater tappings: maximum size all sec tions 1 tV*. Add to Trade Price of boiler $2.00 per section tap ping and $2.00 per jacket tapping. G-60 Right end steam trim tappings for pressure gauge and water column gauge glass furnished when specified on order at Trade Price addition charge of $10.00 per boiler. G-60 DUAL GAS BOILERS Natural and Propane Gases G-60 steam or water boilers are available with dual gas equipment using natural and propane gases. If desired specify on order and add the charge shown below to boiler with standard equipment. Selection of the boiler should be based on the A.G.A. and I=B = R ratings shown on page 13. boiler number add to boiler Trade Price boiler number add to boiler Trade Price G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 $ 95.00 100.00 105.00 110.00 115.00 120.00 145.00 165.00 185.00 G-6019 G-6021 G 6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041 $205.00 225.00 240.00 270.00 300.00 350.00 375.00 445.00 480.00 Dual gas equipment: In addition to boiler with standard trim dual gas boilers include: Two V-532 diaphragm gas valves; two manifolds; gas pres sure regulator 'natural gas onlyi; manual shut-off valves. ribbon burners; 100Cc safety shut-off 'consists of Baso com bination pilot switch and valve with auxiliary Baso pilot valves), pilot cock; outdoor thermostatic adjustable change over control Room thermostat not included in above prices For ordering instructions for gas boilers see page 15 HH 2 Page 14 04543 American-Standard HYDRONIC HEATING BOILR,ST"AS F,RH> G-40 AND G-60 ELECTRONIC Panel System EPG-O: Specifically designed for Factory Mutual <F.M ) and Factory Insurance Association (F.I.A.) installa tions. Provides electronic supervision of each primary pilot each combustion chamber (I to 4) and intermittent eieeti te ignition of all pilots. Complete automatic operation of boiler. 100% safety shut-off Equipment includes: one main control panel with 1 to 3 auxiliary panels pre-wired and factory assembled: Q-179-A flame rod and electric ignition pilots; ignition transformer; V-495-B pilot solenoid valves; RA-890-E electronic relay for each panel with 8 second response timing and alarm contacts. See additional charges below. CONTROL PANEL SYSTEMS off. Available for all gases. Electronic supervision of a pri mary pilot and thermocouple supervision of all auxiliary pilots.^Main burner and pilot burner gas supply turned off or pilot f.iluie. Cuminuous flame pilot operation Equipment includes: one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel; Q-179-B flame rod primary pilot(s) with special adapter for thermocouple, Baso auxiliary pilot burners; Baso 817-F-ll pilot valves with thermocouples; RA-890-E elec tronic relay for each panel with 8 second response timing and alarm contacts See additional charges below. Panel System EPG-1: Provides manual ignition, non-100% shut-off. Available for Natural. Mixed and Manufactured Gas only Electronic supervision of a primary pilot and thermo couple supervision of all auxiliary pilots. Main burner gas supply only turned off on pilot failure. Continuous flame pilot operation. Equipment includes: one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel; Q-179-B flame rod primary pilot (s); Baso auxiliary pilot burners: Baso 850-1 switches with ther mocouples; RA-890-E electronic relay for each panel with .8 second response timing and alarm contacts. See additional charges beltrtv. Panel System EPG-2: Provides a manual ignition, 100% shut- Panel System EPG-3: Provides intermittent electric ignition on a primary pilot and continuous flame auxiliary pilots with 100% shut-off Available for all gases. Electronic supervision of a primary pilot and thermocouple supervision of auxiliary pilots. Main burner and pilot burner gas supply shut-off on pilot failure. Equipment includes: one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel; Q-179-A flame rod and electric ignition primary pilotis); primary pilot solenoid valveisi V-495-B; Baso auxiliary pilot burner; Baso 817-F-ll pilot valves with thermocouples; 6000 volt secondary ignition transformertsi; RA-890-E electronic relay for each panel with 8 second response timing and alarm contacts. See additional charges below ADDITIONAL CHARGES-Trade Price Specify on order type of system desired, as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment Panel System EPG-O boiler number added charge Panel System EPG-1 boiler number added charge * Panel System EPG-2 boiler number added charge Panel System EPG-3 boiler number added charge G- 403 thru 407 G- 408 thru 4010 G- 606 thru 6011 G-6013 thru 6021 G-6022 thru 6031 G-6033 thru 6041 $163.00 177.00 177.00 359.00 538.00 718.00 G- 403 thru 4010 $150.00 G- 606 thru 6037 150.00 G-6041 281.00 Mfd. gas only: G-6028 thru 6037 $281.00 G- 403 thru 4010 $171.00 G- 606 thru 6037 171.00 G-6041 283.00 Mfd. gas only. G-6028 thru 6037 $283.00 G- 403 thru 4010 $185.00 G- 606 thru 6037 185.00 G-6041 334.00 Mfd. gas only: G 6028 thru 6037 $334.00 Panel System EPG-1 available for Natural. Mixed and Manufactured gases only. Balance for all gases. G-40 AND G-60 ELECTRONIC CONTROL SYSTEMS (less Panels) The following systems <EG-0. EG-1. EG-2 and EG-3) are also avatlable, but do not include factory wired and assembled control panel. These systems provide the same function and are equipped with the same basic parts (less panel) as described for EPG-O. EPG-1. EPG-2. and EPG-3. System EG-0: System EG-1: System EG-2: System EG-3: (Samefunction as EPG-O less panel ) (Samefunction as EPG-1 less panel.) (Samefunction as EPG-2 lesspanel.) (Samefunction as EPG-3 less panel.) See additional charges below See additional charges below See additional charges below. See additional charges below. ADDITIONAL CHARGES-Trade Price Specify on order type of system desired, as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment Control System EG4) boiler number added charge G- 403 thru 407 G- 408 thru 4010 G- 606 thru 6011 G-6013 thru 6021 G-6022 thru 6031 G-6033 thru 6041 $108.00 140.00 140.00 280.00 420.00 560.00 Control System EG-1 boiler number added charge G- 403 thru 4010 $ 86.00 G- 606 thru 6037 86.00 G-6041 173.00 Mfd. gas only: G-6028 thru 6037 $173.00 Control System EG-2 boiler number added charge G- 403 thru 4010 $ 96.00 G- 606 thru 6037 96.00 G-6041 175.00 Mfd. gas only: G-6028 thru 6037 $175.00 Control System EG-3 boiler number added charge G- 403 thru 4010 $113.00 G- 606 thru 6037 113.00 G-6041 227.00 Mfd. gas only: G-6028 thru 6037 $227.00 Control System EG-1 available for Natural. Mixed and Manufactured gases only. Balance for all gases Ignition Cable: Trade Price per foot Flame rod wire: Trade Price per foot $0.70 $0.40 Orders must specify: GAS BOILERS--Instructions for Ordering 1 1 > Complete Boiler Number. i2> Steam or water '31 Equipment desired- Regular. "DW" or IS", etc Type of gas ' If LP-gas. whether butane or propane 1 15 Btu `heal value of gas' and specific gravity 16> Elevation al point of installation if in excess uf 2 OuO feet T > Pressui e available at outlet of gas meter Page 15 HH 2 04544 INSHOT GAS BURNERS American-Standard H Y D R O N I C HEATI N G INSHOT GAS CONVERSION BURNER -- Factory assembled control! regularly furnished are for 115 volt, 60 cycle current A.G.A. ratlngi-Btu Input par hour modal numbtr IN-150 IN-245 IN-275 Inputs (min (max fmin (max {min (max Nat and Mxd. Gaa 80,000 150,000 130.000 245.000 130.000 275.000 Mfd. Gas 80,000) 150,000) not ) available) not ) available) Trada Prfca with standard aqulpmant Net end Mxd. Get Mfd. Gas $68.00 $73.25 approx. walght 20 $74.50 $83.75 not available not available 21 21 Gas valva sizat: l/tm for IN150 Nat and Mxd. Gat, for all othar tlzat. Shoot motol mounting plata roquirod for all othar convarsiont axcapt Arcoleadar and Arcoliner Wat Base oil boliert. This plata to ba fumishad by installar. If CA-520 tharmostat not desired, deduct $7.74 from Trade Price shown above. INSHOT GAS BURNER MAXIMUM INPUTS FOR ARCOLEADER AND ARCOLINER BOILERS Burner Model: Type of gas: IN-150 Nat. Mxd. Mfd. IN-245 Nat. Mxd. only IN-275 Nat. Mxd. only IN-275 Nat. Mxd. only Maximum Gas Inputs -- Btu/hr. Boiler Model 3 eectlon 4 lection 5 eectlon 6 eectlon Arcoleader Arcoliner 115.000 120.000 160,000 170,000 210,000 200,000 260,000 6-Section Arcoliner Is not recommended for (as firing Standard equipment Includes: CA-520 thermostat. Runner pilot ignition. Manual shut-off valve. Control housing. Stainless steel flame spreader. Pilot throttling valve. Pilot filter--with mfd. gas burners only. Two main burner orifices: one drilled for minimum input, factory installed; the second, also drilled for minimum input, is provided. Models IN-150 and IN-245 V-600 series combination gas valve, pressure regulator and safety pilot switch, transformer, manual opener. Model IN-275 General Controls KX3H quiet solenoid gas valve, plug-in safety pilot switch, transformer, manual opener. Gas pressure regulator. Optional equipment: Self-energizing control,! General Controls T80-A thermostat, B-60 gas valve and PG9 pilot generator-if desired, specify on order: Bumar Modal oft?. Trade Charge IN-150 IN-150 IN-245 IN-275 Nat and Mxd. Mfd. Nat. and Mxd. Nat. and Mxd. No extra cost Add $2.75 Add 2.75 No extra cost Select from list below special limit control which must be used with telf-energlzlRg controls. 100% safety shut-off, all models, specify on order and add $2.00 to Trade Price above. Pilot filter--regularly furnished only for Mfd. gas. If desired for Nat. and Mxd. gas, specify on order and add $1.50 to Trade Price above. Optional controls for self-energizing (millivolt) application: Number L-52A10A1A L-39PA412 S45A1A3A3 S45A5AM3 Description General Controlsimmersion limit control.................. General Controls pressure boiler limit control, scale 0-10 lbs............................................................................... General Controls warm air limit control.................... General Controlsfan and limit control....................... For other optional controls, see pege 32. Trade Price $10.75 11.44 3.30 6.71 Orders must specify: GAS CONVERSION BURNERS--Instructions for Ordering 1. Type of gas. 2. Btu (heat value of gas) and specific gravity. For discount on repairs, see page 2. - 3. Pressure available at outlet of gas meter. 4. Optional controls, if desired. HH-2 Page 16 04545 AMERiCAN-<Standard HYDRONIC HEATINO packaged BOILER-BURNER UNITS wait* ARCOLEADER PACKAGED BOILER-BURNER UNITS Designed and equipped with tonfrels for forced clreulstien. Factory assembled and crated. Wet base construction. Flush jacket. WATER packaged unit numbtr groti l=BsR output Mbh IsBsR bumar capacity gph tanldaaa haatar iiumbir A IsWsH rating nat IsBsR rating Mbh nat rating tq ft watar Trad# Plica with standard aqulpmant chlmnay alza approx. shipping weight Packaged units less tankless heater A1-3P A1-4-P A1-5-P 100 136 173 0.95 1.30 1.65 75.0 102.0 129.8 500 680 865 $447.00 498.00 569.00 8x8x 15 8x8x 15 8x8x 15 661 811 959 Packaged units with factory installed tankless heater A1-3-PT A1-4-PT A1-5-PT 100 0.95 732 33/i 136 1.30 732 4V4 173 1.65 743 5V4 75.0 102.0 129.8 500 680 865 $469.00 523.00 613.00 *Nozzle sizes, gph, furnished with Arcoleeder packiged units: Al'3'P. 0.90-70* H: A1-4-P. 1.25-60* H; A1-5-P, 1.50-60* S. A Gallons of water par minute heated from 40F to 140F with 2OOF boiler water temperature. 8x8x 15 8x8x 15 8x8x15 673 824 991 Standard equipment all Units: (see options, page 19) Model DH-5 Arcoflame oil burner with sling mounting for front firing. CA-701 primary con trol. Draft stabilizer. ASME relief valve. Heat Lib-O-Rator high temperature steel combus tion chamber. IV," circulator with piping. Wiring harness. Drain valve. Theraltimeter. Motors and controls regularly furnished are for 115 volt, 60 cycle current. Additional standard equipment for units with factory installed heater Built-in tankless heater as listed above. No. 36 Arcoflame control set (CA-520 thermostat, CA-610 combination immersion controlhigh, low limit, circulator control, built-in relay) and nozzle. Additional standard equipment for units less heater: No. 33 Arcoflame control set (CA-520 thermostat, CB-614 combination immersion controlhigh limit and circulator control) and nozzle. Heater opening cover plate. NotirUnits are shipped with flush jacket and with all electrical controls (except thermostat). circulator and piping, factory installed and wired. Arcoflame oil burner shipped separately. Draft stabilizer, relief valve and thermostat are secured inside boiler crate. For complete information on boiler ratings, see page 2. For discount on repairs, see Dage 2. Pig, 17 04546 HH-2 boiler-burner units OIL FIRED BOILERS WATU Ame mcAN'^tandard HYDRONIC HEATING ARCOLEADER BOILER-BURNER UNITS Designod and equipped with controls for forced circulation. Wet base construction. VI ith jacket Factory assembled sections. WATER b<lir> burner unit number cross l=B=R output Moh l=B=R burner capacity IJ>* tankless heater number |=WA=Hratine Units less factory installed tankless heater A1-3-B A1-4-B A1-5-B A1-6-B A1-7-B 100 0.95 136 1.30 173 1.65 208 1.95 244 2.30 Units with factory installed tankless heater A1-3-BT A1-4-BT A1-5-BT A1-6-BT A1-7-BT 100 0.95 732 3y, 136 1.30 732 4/ 173 1.65 743 5 Vi 208 1.95 743 6 244 2.30 743 6 net l=B=R rating Mbh 75.0 102.0 129.8 156.0 183.0 75.0 102.0 129.8 156.0 183.0 net rating sq ft water 500 680 865 1040 1220 500 680 865 1040 1220 Trade Price with standard equipment $349.00 412.00 480.00 544.00 612.00 $384.00 447.00 534.00 598.00 666.00 chimney size 8x8x 15 8x8x 15 8x8x 15 8x8x 15 8x 12 x 15 8x8x 15 8x8x 15 8x8x 15 8x8x 15 8x 12 x 15 appro*. shipping weight 586 726 882 1051 1197 596 740 906 1087 1233 Nozzle sizes, sph. furnished with Arcoleader boiler-burner units: Al-3-8, 0.90-70* H; A1-4-B. 1.25-60* H: A1-5-B. 1.50-60* S: A1-6-B, 1.75-60* S: A1-7 B, 2.00-60* S. Gallons of water per minute heated from 40F to 140F with 2OOF boiler water temperature. Standard equipment all Units: (see options page 19) Model DH-5 Arcoflame oil burner with sling mounting tor front firing. CA-701 primary con trol. Draft stabilizer. ASME relief valve. Theraltimeter. Heat Lib-O-Rator high temperature steel combustion chamber. Motors and controls regularly furnished are for 115 volt, 60 cycle current. Additional standard equipment for units with tankless heaters: Tankless heater as shown above factory installed in section assembly. No. 36 Arcoflame control set (CA-520 thermostat, CA-610 combination immersion controlhigh, low limit, circulator control, built-in relay) and nozzle. Additional standard equipment for units less heater No. 33 Arcoflame control set (CA-520 thermostat, CB-614 combination immersion controlhigh limit and circulator control) and nozzle. Heater opening cover plate. ARCOLEADER OIL FIRED BOILERS WATER Wet base construction. Factory assembled sections. Flush jacket. boiler number gross 1=B=R output Mbh l=B=R burner capacity gph tankless heater number A l=W=H rating Boiler less factory installed tan (less hea ter net l=B=R rating Mbh net rating sq ft water Al-3 Al-4 Al-5 Al-6 Al-7 100 0.95 136 1.30 173 1.65 208 1.95 244 2.30 Boiler with factory installed tankless heater 75.0 102.0 129.8 156.0 183.0 500 680 865 1040 1220 A1-3-T A1-4-T A1-5-T A1-6-T A1-7T 100 0.95 136 1.30 173 1.65 208 1.95 244 2.30 732 3y, 732 4 Vi 743 5'/2 743 6 743 6 75.0 102.0 129.8 156.0 183.0 500 680 865 1040 1220 Trade Price $228.00 291.00 359.00 423.00 491.00 $254.00 317.00 404.00 468.00 536.00 chimney size 8x8x15 8x8x 15 8x8x 15 8x8x 15 8 x 12x15 8x8x 15 8x8x 15 8x8x 15 8x8x 15 8 x 12 x15 approx. shipping weight 583 730 894 992 1138 593 744 919 1022 1168 Gallons of water per minute heated from 40F to 140F with 200F boiler water temperature. Standard equipment all boilers: (see options page 19) Heat Lib-O-Rator high temperature steel combustion chamber. ASME Relief Valve. Theraltimeter. Additional standard equipment boilers with tankless heaters: Tankless heater as listed above factory installed in section assembly. Note: Boilers less factory installed tankless heater are shipped less water heater opening cover unless specified on order. ' For complete information on boiler ratings, see page 2. For discount on repairs, see page 2, HH-2 Page 18 04547 AMERiCAN-<Standard bo.ler-burner units HYDRONICHE AT INC 0,1 F,RED BOILERS ________________________________________________________________________________ ______________ _______________________________ WATll ARCOLEADER OPTIONAL EQUIPMENT PACKAGED BOILER-BURNER UNITS only: WAk_\._l _! t, iAtX jUC _J:it t'UI_____ ,>-rl-"- -"- J .JJut*M oUo'An'* Fr. " * " ---- - .Dc-ip.- - W*itn- T-Men* extension, shipped in separate carton, provides 15-%" enclosure in front for concealment of oil burner and controls; approximate shipping weight 35 lbs, Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra. Add-on No. 36-Z Arcoflame control set will be furnished when specified on order at $20.35 Trade Price extra. (Add-on zone. Use only with No. 36 control set.) Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30. BOILER-BURNER UNITS only: Arcoflame control sets other than those included in Trade Price of boiler-burner units will be furnished when specified on order at the following charges: Contra) Sot With Hoatar Water control set No. 13 -- Water control set No. 36 -- Water control set No. 36-Z $20.35 (Add'On zone. Use only with No. 36 control set.) Lass Halter * $ 9.10 20.35 * Boiler-burner units less heiter can be ordered for use on gravity systems: Specify No. 13 Arcoflame control set and deduct $5.90 from Trade Price of unit less heater and specify water heater opening cover plate with 3* tapping. Detailed description of Arcoflame control sets is shown on page 32. Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra. Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30. BOILER-BURNER UNITS or OIL FIRED BOILERS: Jacket extension; if desired specify on order and add $26.00 to Trade Price of boiler. Jacket extension provides 1534" enclosure in front for concealment of oil burner and controls. Approximate shipping weight 35 lbs. Oil fired boiler heater opening cover plate: furnished only when specified on order at no charge. If specified on order cover plate can be tapped 3" for gravity installations. BUILT-IN HEATERS: Built-in tankless heaters can be ordered for separate shipment with Boiler-Burner units or Oil Fired Boilers less factory installed tankless heaters at the following Trade Prices: Hatter number 723 732 743 Trade Price $25.00 27.10 47.70 NOTE: for I--W--H ratings and boilers with which heaters can be used, see table below. Water mixing valves: for prices, see page 32. ARCOLEADER l=W=H RATED TANKLESS HEATERS Heaters tested with boilers. Built-in tankless heaters for Arcoleader Boiler-Burner units and Oil Boilers can be ordered for separate shipment with units or boilers specified less tankless heaters. See Trade Prices above. Select heater desired from table below. unit or boiler size l=B=R burner capacity gph heatar 723 A l=W=H rating heater 732 heater 743 Al-3 0.95 3 Vi 3 Vi Al-4 1.30 3 Vi 4 Vi Al-5 1.65 3 V* 4 Vi 5'/2 Al-6 1.95 3 Vi 4 Vi 6 Al-7 2.30 3 Vt 4 Vi 6 A Gallons of water per minute heated from 40? to 140? with 200? boiler water temperature. For discount on repairs, see page 2. Page 19 MH-2 04548 BOILER-BURNER UNITS OIL FIRED BOILERS ITIAM AND WATIR AMERicAN-fStandard HYDRONIC HEATING ARCOLINER BOILER-BURNER UNITS Wet base construction. Flush jacket. Factory assembled sections. Arranged for but less Built-in Tank or Tankless Type Water Heater boller-bumer unit number STEAM WATER WIDE BACK TYPE SO-153-BT S-0 154-B-T S-0 155-B-T S-0-156-B-T W-0-153-B-T W-O-154-B-T W-O-155-B-T W-0-156-B-T grot* l=B=R output Mbh l=B=R bumtr capacity gph net l=B =R rating ft steam Mbh 97 1.00 303 72.8 132 1.35 413 99.0 164 1.60 513 123.0 188 1.80 588 141.0 nat rating eq ft water 485 660 820 940 Trada Price with standard equipment Chlmnay liZI $353.55 416.55 475.15 518.15 8 x 8 x 20 8 x 8 x 20 8 x 8 x 25 8 x 8 x 25 approx. shipping weight 851 1010 1163 1394 Nozzle sizes, gel. per hour, furnished with Areollner Boiler-Bumer Units ere as follows: No. 153. 0.90-70* H; No. 154. 1.25-60* H; No. 155. 1.50-60* S: No. 156. 1.65-60* S. Standard equipment: (see options, next page) Model DH-5 Arcofiame oil burner with sling mounting for front firing. CA-701 primary control. Draft stabilizer. Heat Lib-O-Rator high temperature steel combustion chamber (no deduction for omission). Motors and controls regularly furnished are for 115 volt. 60 cycle current. Steam only; No. 11 Arcofiame control set (CA-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge, ASME safety valve, gauge glass and trimmings. Water only: No. 13 Arcofiame control set (CA-520 thermostat, CA-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve. ARCOLINER OIL FIRED BOILERS Wet base construction. Flush jacket. Factory assembled sections. Arranged for but less Built-in Tank or Tankless Type Water Heater boiler number STEAM WATER WIDE BACK TYPE groat l=B=R output Mbh l=B=R burner capacity gph net 1=0 =R rating sq ft team Mbh nt rating aq ft watar S-0-153-T S-0-154-T S-0-155-T S-0-156-T W-0-153-T W-0-154-T W-0-155-T W-0-156-T 97 1.00 303 72.8 485 132 1.35 413 99.0 660 164 1.60 513 123.0 820 188 1.80 588 141.0 940 Trade Price with standard equipment $228.00 291.00 349.00 392.00 Standard equipment: (see options, next page) Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water Theraltimeter and ASME relief valve. Chimney size 8 x 8 x 20 8 x 8 x 20 8 x 8 x 25 8 x 8 x 25 approx. shipping weight 772 930 1083 1234 Jacket extension shown a For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH2 Page 20 04549 AMERicAN-^Standard HYDRONIC HE ATI NO ARCOUNER OPTIONAL EQUIPMENT BOILER-BURNER UNITS only: Arcoflame control sets other than those included in Trade Price of Boiler-Burner Units will be furnished when specified on order at the following added charges: Control sot Added Chare* Steam control set No. 12...................................$13.30 Water control set No. 15.................................. 22.75 Water control set No. 16.................................. 24.40 Water control set No. 16-Z................................ 53.20 Water control set No. 26 .................................. 24.40 Water control set No. 33.................................. 5.90 Detailed description of Arcoflame control sets is shown on page 32. Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra. BOILER-BURNER UNITS or OIL FIRED BOILERS: Jacket extension: if desired specify on order and add *27.50 to Trade Price of boiler. Jacket extension provides 20W" en closure in front for concealment of oil burner and controls. Approximate shipping weight 47 lbs. Water mixing valves: for prices, see page 32. For low water cut-off for use with steam units, see page 32. Molded refractory combustion chambers: available for Oil Boilers at Trade Prices below when specified on order. Cover plate for water heater opening will be furnished if specified on order at added Trade Price charge of $4.00. Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30. 450-BC-l Vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam units see page 31 for added charge. The Heat Lib-O-Rator molded refractory type combustion chamber shown below for Arcoliner Boilers may be specified in place of steel chambers regularly furnished at no charge for No. 153-B-T or 154-B-T. Add to Trade Price for boiler No. 155-B-T $2.85 and for No. 156-B-T $5.75. BUILT-IN HEATERS: Below are the ratings and Trade Prices covering Built-in tank or tankless heaters available for Arcoliner Units. For detailed information on ratings, see page 2. Haatar No. 587 589 596 Hiatir T>p* tank tankless tankless Haat*r Ratings gals, capacity 85 3 per minute 3`/2 per minute Trad* Pric* $22.60 29.90 35.00 apprex. shipping walght 23 25 27 HEAT UB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS bollar numbar 153-T) 154-Tj 155-T 156-T H*at Ub-O-Rator modal no. No. 4 No. 5 No. 6 max. firing rata gal. p*r nour 1.35 1.65 2.00 Trad* Pric* $10.95 13.85 16.75 For discount on repairs, see page 2. Pig* 21 approx. shipping waigftt 77 86 90 HH-2 04550 wmxBohNrnmwTs OIU (FIRED IBOILERS ITU* AHP WMW AMfemc^N-^tanda^a H Y, DHO Nl C UtAT I N Q rpmw Flush jacket. boller-bumer STEAM WATER fro** f*:B=R output Mbh - ,, * UsBsR. bumor capacity CPh n*tl=B =R rating <i steam Mbh not rating water Trade Price with squlpmsnt chlmnay approx. shipping weight Arranged for but less Built-in Tank or Tankless Type Water Heater S-84-OB S-85-OB S-86-OB S-87-OB S-88-OB S-89-OB >. W-84-OB W-85-OB W-86-OB W-87-OB W-88-OB W-89-OB 143 175 202 230 261 288 1.40 1.75 2.00 2.30 2.55 2.80 447 547 631 719 816 900 107.3 131.3 151.5 172.5 195.8 216.1 715 875 1010 1150 1305 1440 $452.15 512.70 557.35 609.85 666.85 713.85 8ot 8 x 20 8 x 8 x 25 8 x 8 x 25 8 x 12 x 30 8 x 12x30 8 x 12 x 35 1338 1479 1603 1746 1863 2007 *Nozzle sizes, gph, 60* S. furnished with Oekmont boiler-burner units: No. 64, 145; No. 65. 1.65; No. 86, 2.00; No. 67. 2.25; No. 88, 2.50; No. 89, 2.75. Standard equipment: (see options, next page) Model DH-5 Arcoflame oil burner with sling mounting for rear firing. CA-701 primary control. Draft stabilizer.. Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omis sion listed on page 23. Motors and controls regularly furnished are for 115 volt, 60 cycle current. Steam only: No. 11 Arcoflame control set (CA-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge, ASME safety valve, gauge glass and trimmings. Water only: No. 13 Arcoflame control set (CA-520 thermostat, CA-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve. OAKMONT OIL FIRED BOILERS Flush jacket. Arranged for but less Built-in Tank or Tankless Type Water Heater hollar number STEAM WATER frees l=B=R outgut l=B=R burner capacity *Pb nat l=B =R ratine *q ft team Mbh net ratine sq ft water Trade Price with standard equipment S-84 S-85 S-86 S-87 S-88 S-89 W-84 W-85 W-86 W-87 W-88 W-89 143 175 202 230 261 288 1.40 1.75 2.00 2.30 2.55 2.80 447 547 631 719 816 900 107.3 131.3 151.5 172.5 195.8 216.1 715 875 1010 1150 1305 1440 $320.00 379.00 422.00 472.00 529.00 576.00 chlmnay size 8 x 8 x 20 8 x 8 x 25 8 x 8 x 25 8x12x30 8 x 12 x 30 8 x 12 x 35 Standard equipment: (see options, next page) . Steam: ...... Steam gauge, ASME safety valve, gauge glass and trimmings. Water Theraltimeter and ASME relief valve. approx. shipping weight 1109 1245 1352 1485 1602 1746 a For complete information on boiler ratings, see page 2. For discount on repairs,, see page 2..... HH2 .... Pin 22 ............... 04551 Ambrigan-<tandat# H YD RON I C HEATING i ' 'W - -t v HS:>. v j-c OAKMONT OPTIONAL EQUIPMENT BOAerUMI^NIt8t OIL ? FIRED1. BOILERS (TUM AMD WATTA BOILER-BURNER UNITS only] Arcoflame control sets other than those included in Trade Price of Boiler-Burner Units will be furnished when speci fied on order at the following added charges: Central Set Added Charge Steam control set No. 12.................................... $13.30 Water control set No. 15................................... 22.75 Water control set No. 16................................... 24.40 Water control set No. 16-Z................................. 53.20 Water control set No. 26................................... 24.40 Water control set No. 33................................... 5.90 Detailed description of Arcoflame control sets is shown on page 32. Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra. Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30. 450-BC-l vapor limit contra); if desired in place of 450-BA-l pressure limit control regularly furnished for deem units-- see page 31 for added charge. BOILER-BURNER UNITS or OIL FIRED BOILERS: Jacket extension; if desired specify on order and add $33.25 to Trade Price of boiler. Jacket extension provides 1544" en closure at rear for concealment of oil burner and controls. Approximate shipping weight 51 lbs. Water mixing valves: for prices, see page 32. For low water cut-off for use with steam units, see page 32. Molded refractory combustion chambers; added Trade Prices to Oil Boiler Trade Prices are same as "Deduct for Omis sion" Prices shown below and will be furnished when speci fied. Cover plate for water heater opening will be furnished If specified on order at added Trade Price charge of $4.50. BUILT-IN HEATERS: Below are the ratings and Trade Prices covering Built-in tank or tankless heaters available for Oakmont units. For detailed information on ratings, see page 2. Hotter No. 598 599 583 585 597 Motor Typo tank tank tankless tankless tankless Hotor Ratings gals, capacity 40 100 3 per minute 3 V4 per minute 4>/i per minute Trade Price $16.00 24.20 38.00 40.50 60.00 approx. shipping weight 23 27 .83 104 92 imtt number 84 85 86 871 88 > 89J HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS Hast Ub-O-Rator model No. included No. 00 No. 1 No. 2 No. 3 maximum firing rate gallons per hour 1.50 1.75 2.25 3.00 deduct for omission $17.00 18.55 20.20 22.70 approx. shipping weight 148 153 170 180 For discount on repairs, see page 2. Pi< 23 04552 H H-2 Awfertft^-^tattdard OILJ FIRED) SOILKRS mu amo wAm rtYDft^lC H^AYlWOf SEVERN BOILER-BURNER UNITS Flush jacket bollar-bumar STEAM 1 WATER YffaisA lf|*'&itng J A ,Inatiilad radiation 1 _l___ l!_____ S ri 1 taam 1 Uhh <! ** water NOT TAPPED FOR BUILT-IN TANK TYPE WATER HEATER (see option*) S-17-OB S-21-OB S-25-OB S-29-OB S-33-OB S-37-OB W-17-OB W-21-OB W-25-OB W-29-OB W-33-OB W-37-OB 146 168 188 216 247 278 1.5 1.7 "1.9 2.2 2.5 2.8 . 456 525 588 675 772 869 . 109.5 126.0 141.0 162.0 185.3 208.6 730 840 940 1080 1235 1390 T TS3e ' standard qufpmant $471.70 509.70 548.35 589.35 650.85 706.85 ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER S17-OBT 1 r W17-OB-T 146 1.5 456 109.5 730 $477.70 S-21-OB-T W-21-OB-T 168 1.7 525 126.0 840 515.70 S-25-OB-T W-25-OBT 188 1.9 588 141.0 940 554.35 S29-OB-T W-29-OB-T 216 2.2 675 162.0 1080 595.35 S-33-OB-T W-33-OB-T 247 2.5 772 185.3 1235 656.85 S-37-OB-T W-37-OBT 278 2.8 869 208.6 1390 712.85 *Nozzla tizts. gph 60*S, fumithad with Savam boflar-burnar unite No. 17, US; No. 21, 1.50; No. 25. 1.75; No. 29, 2.00; No. 33. 2.25; No. 37. 2.50. 1 1 shipping 1 1303 1458 1570 1710 1815 1975 1312 1461 1579 1719 1824 1984 Standard equipment: (see options, next page) Model DH-8 Arcoflame oil burner with sling mounting for front firing. CA-701 primary control. Draft stabilizer. Heat Lib-O-Rator refractory combustion Chamber; model number and deduction for omis sion listed on page 25. Motors and controls regularly furnished are for 115 volt, 60 cycle current. Steam only. No. 11 Arcoflame control set (CA-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge, ASME safety valve, gauge glass and trimmings. Water only: No. 13 Arcoflame control set (CA-520 thermostat, CA-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve. SEVERN OIL FIRED BOILERS Flush jacket. boJIar-numbar STEAM | WATER grots output Mbh firing ratt fph Installed radiation M| ft ataam Mbh NOT TAPPED FOR BUILT-IN T LNK TYPE WATER H EATER (see options) sq ft watar S-17-0 S-21-O S-25-O S-29-0 S-33-0 S-37-O W-17-0 W-21-0 W-25-0 W-29-0 W-33-0 W-37-0 146 1.5 456 109.5 730 168 1.7 525 126.0 840 188 1.9 588 141.0 940 216 2.2 675 162.0 1080 247 2.5 772 185.3 1235 278 2.8 869 208.6 1390 ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER S-17-OT S-210T S-25-OT S-29-0-T S-33-OT S-37-0-T W-17-O-T W-21-O-T W-25-0-T W-29-O-T W-330-T W-37-0-T 146 168 188 216 247 278 1.5 456 109.5 730 1.7 525 126.0 840 1.9 588 141.0 940 2.2 675 162.0 1080 2.5 772 185.3 1235 2.8 '869 208.6 1390 Standard equipment: (see options, next page) Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water , Theraltimeter and ASME relief valve. Trada Prlca with standard aqulpmant $338.00 376.00 413.00 454.00 513.00 569.00 $344.00 382.00 419.00 460.00 519.00 575.00 For complete Information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-2 -- r. -I ---------------------------------------------------- ~ Tl|T ... approx. shipping weight 1075 1230 1325 1465 1560 1720 1084 1239 1334 1474 1569 1729 04553 AMERiGAk-fStandard HYDRO.fi I CL> HEATING print* v* SEVERN OPTIONAL EQUIPMENT toher-burner^ units dOIL'FlREDlBOILERS swam andwatu BOILER-BURNER UNITS only: . Arcoflame control acts other than those included in Trade Price of Boiler-Burner Units will be furnished when specified on order at the following added charges: Control Set Added Charge Steam control set No. 12.................................. $13.30 Water control set No. 15................................. 22.75 Water control set No. 16................................. 24.40 Water control set No. 16-Z............................... 53.20 Water control set No. 26 ................................. 24.40 Water control set No. 33................................. 5.90 Detailed description of Arcofiame control sets is shown on page 32. Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra. Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30. 450-BC-l vapor limit control: If desired in place of 450-BA.-1 pressure limit control regularly furnished for steam unitssee page 31 for added charge. BOILER-BURNER UNITS or OIL FIRED BOILERS: Water mixing valves: for prices, see page 32. For low water cut-off for use with steam units, see page 32. Molded refractory combustion chamber; added Trade Prices to Oil Boiler Trade Prices are same as "Deduct for Omission" Prices shown below and will be furnished when specified. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at an added Trade Price charge of $3.70. BUILT-IN HEATERS: If 2%' right or left side tapping in back section for Built-in heater No. 703 is desired, specify on order and add $2.00 to Trade Price of unit or boiler. Below are the ratings and Trade Prices covering Built-in tank or tankless heaters available for Severn units. For detailed information on ratings, see page 2. - ' Hulir No. 703 594 595 590 Hwtir Typo Hsater Ratine* gal*, capacity tank tank tank tankless 66 100 160 3 Vi per minute Trade . Price $ 9.00 48.00 42.50 36.00 approx. hipping weight 7 54 51 60 HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS unit number Meet UWWUtoc model No. Included maximum firing rata gallons per hour deduct for omission approx. shipping weight 17. 21 25, 29 33, 37 No. 1 No. 2 No. 3 1.75 2.25 3.00 $18.55 20.20 " r 22.70 153 170 180 For discount on repairs, see page 2. P* 25 04554 HH-2 imMttMNttc? nccatcno: .yW>li:ER:BURNER UNITS -a . . >........ Msenttnumber ... ` ------ 'STEAM WATER Flush Jacket imw.rtnw witfr worldpj pressure. ------- 1------- grow l=B=R output Mol) IsSsR burntr capacity ___ rp* _ net 1=1 =R rating *twm Mbh not ratine soft watar Trada Prica wHh Undard qulpmont For Built-In Water Heater Arrangement, see page 27 chlmnoy Iza approx. thlMinc watgfrt iivA-504-SB' 1 . . A-505-SB . A-506-SB A-507-SB A-508-SB A-509-SB A-510-SB . A-511-SB ^A-504-WB A-505-WB -.A-506-WB A-507-WB A-508-WB A-509-WB A-510-WB A-511-WB 261 346 426 508 588 668 748 830 2.55 3.30 4.00 4.75 5.55 6.30 7.00 7.65 816 1082 1332 1588 1838 2088 2338 2594 195.8 259.6 319.6 381.1 441.1 501.1 561.1 622.7 1305 1731 2131 2541 2941 3341 3741 4151 $ 692.05 827.90 924.55 1029.55 1115.55 1213.60 1411.60 1505.60 8 x 12* 15 8 x 12 x 20 12 x 12 x 20 12 x 12 x 20 12 x 16 x 25 12 x 16x25 12 x 16 x 25 16x16x30 1702 1969 2286 2563 2807 3107 3382 3684 Nozil. tizmt. fph, furnished with A-S units art as follows: No. A-504, 1 2.50 60'S; A-505. 2 1.65 70'S; A-506 2 2.00 70'S: A-507 1 2.25 & 1 2.50 BO'S; A-508 2 2.75 80*S; A-509. 1 3.00 A 1 3.25 BO'S: A-510 2 3.50 BO'S; A-511 1 3.50 A 1 4.00 BO'S. Standard equipment: (sea options, noxt page) OH-5 sling mounted oil burner for A-504, with 1-stage fuel unit. 45W-3606 oil burner for A-505, A-506; 62A-7056 oil burner for A-507, A-508, A-509; 45W-3606 and 62A-7056, flange mounted, with 2-stage fuel unit. The above burners are furnished with CA-701 primary controL 96-7506 oil burner for A-510, A-511; flange mounted, with 2-stage fuel unit; electronic Same safeguard control consisting of C7013A photocell installed in burner; Q270A safety switch base mounted on burner housing; RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly. Draft stabilizer. Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omission listed on page 27. Motors and controls regularly furnished are for 115 volt, 60 cycle current. Steam only; No. 11 Arcoflame control set (CA-520 thermostat, 450-BA-l pressure limit control) and nozzle (s). Steam gauge, ASMS safety valve, gauge glass and trimmings. Water only; No. 13 Arcoflame control set (CA-520 thermostat, CA-655 immersion limit control) and nozzle (s). Theraltimeter and ASME relief valve for 50 lbs. A-5 OIL FIRED BOILERS Flush jacket. Tested and equipped for 50 lbs. water working pressure. boilar numbar STEAM WATER frow IsBsR output Mbh l=S=R bumar capacity *ph nat l=B sR ratine *q ft staam Mbh nat rating tq ft watar Trada Prica For Built-in Water Heater Arrangement, see page 27. A-504-S A-505-S A-506-S A-507-S A-508-S A-509-S A-510-S A-511-S A-504-W A-505-W A-506-W A-507-W A-508-W A-509-W A-510-W A-511-W 261 346 426 508 588 668 748 830 2.55 3.30 4.00 4.75 5.55 6.30 7.00 7.65 816 1082 1332 1588 1838 2088 2338 2594 195.8 259.6 319.6 381.1 441.1 501.1 561.1 622.7 1305 1731 2131 2541 2941 3341 3741 4151 $ 553.00 645.00 733.00 822.00 908.00 996.00 1084.00 1178.00 Standard equipment: (see options, next page) Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water Theraltimeter and ASME relief valve for 50 lbs.______________ a For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-2 Paga 25 chimnay tin 8x 12 x 15 8 x 12 x 20 12 x 12x20 12 x 12 x 20 12 x 16x25 12 x 16x25 12 x 16x25 16 x 16x30 approx. ahlppine walgttt 1489 1750 2050 2306 2550 2825 3075 3377 04555 I I: t'-r< AMferac^-i$tandat7i H Y D R.0JU CD HC Ajr INO AOILER-SURNER^UNITS iOIt! fIRED' BOILERS miAM^NB WATn A-5 OPTIONAL EQUIPMENT , BOILER-BURNER UNITS enlyi Arcoflame control ceta other than those included in Trade Price of boiler-burner units will be furnished when specified on order at the following added charges: Control Sot Added Charge Steam control set No. 12 ......... . $13.30 " Water control set No. 15.......... 22.75 Water control set No. 33 ................ 5.90 Water control set No. 36 . %z.. . 15.05 - Water control set No. 36-Z .. 0.35 (Add-on tone. Uea only with No. 36 control eat) Detailed description of Arcoflame control sets is shown on page 32. Electronic flame safeguard equipment: 62A-70S6F burner with electronic flame safeguard control la available instead of 62A-70S6 burner for A-507, A-508 and A-S09. boiler-bumer units at added Trade Price charge of $93.00. The electronic control con* slats of C7013A photocell Installed In burner. Q270A safety switch base mounted on burner housing. RA890E safety switch packed with burner; delayed oil valve Installed between fuel unit and drawer assembly. For InstallaUona requiring Factory Mutual Approval and In states and municipalities with regulations more stringent than Underwriters' Lab oratories. Inc., oil burners are available with special electronic flame safeguard controls for A-5 boiler-bumer units as follows: 62-A-7056 FFM burner for A-507. A-508 and A'509 boiler-bumer units, at added Trade Price charge of $133.00. 96-7507 burner for A-510 and A-511 boiler-bumer units at added Trade Price charge of $30.00. Motors and controls regularly furnished are for 1 IS volt 60 cycle. 450-BC-l vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam unitssee page 31 for added charge. Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30. Two-stage fuel unit for DH-5 Arcoflame o11 burner will be furnished when specified on order at $5.00 Trade Price extra. BOILER-BURNER UNITS or OIL FIRED BOILERS: Jacket extension; if desired specify on order and add $33.85 to Trade Price of boiler. Jacket extension provides 25" en closure in front for concealment of oil burner and controls. Approximate shipping weight 57 lbs. Water mixing valves: for prices, see page 32. For low water cut-off for use with steam units, see page 32. .Molded refractory combustion chembert`for A-5 boilers: Trade Prices are same as "Deduct for Omissi6n"Prices shown below. c- If desired, provision for tankless heaters is available at no additional charge. When suffix letter "T" is added on order to unit or boiler numbers, the following number of openings in center sections will be furnished. Unit No. Openings A-504-T 2 A-505-T thru A-508-T 3 i- A-509-T thru A-511-T 4 Not*-. Additional openings can be specified on order. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $335 each. NO. 530 TANKLESS HEATER: No. 530 tankless heater available .in single or quantity lot price at $30.65 Trade Price each. _ The following table shows the recommended number of heat ers to be used with each boiler and the ratings/attained if more than one heater is connected in. parallel: boiler no. . All Sizes All Sizes A-505--A-511 A-508--A-51X A-510--A-511 nbbofhoatora 1 -: 2 3 4 5 radng-gpm 4 7 10 .13 16 Note: Additional hatters can b added if Ihe heater* are aarving differ ent system* and It Is not likely that heaters will all be In use at the same time. -Gallona of water per minute raised from 40 F to 140 F with 200 F boiler water temperature. Copper pipe manifolds factory assembled for multiple heater parallel hookup shipped in boxes of two manifold assemblies per box when specified with heaters are available at the fol lowing charges: Manifold assembly 2 heater 3 heater 4 heater Trade Price per Bex $4.80 6.80 8.80 HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS unit number A-504 A-505 A-506, A-507. A-508 A-509, A-510, A-511 Hoot Ub-O-FUtor modJ No. Included 14-A 16-A 16-A 17-A '" maximum firing rata gallon* par hour 2.55 3.30 5.55 7.65 deduct for omlwion $23.90 23.90 32.55 37.60 ______ 'i1 __________ approx. shipping weight 158 163 180 200 For discount on repairs, see page 2. 7 Paga 27 04556 HH-2 BOILER"BURNER UNITS OIL' FIRED! BOILERS ITUa AMO WATt* American-vStandard HYDBONIC HE ATI NO A-7 BOILER-BURNER UNITS Jacketed and unjacketed. Tested and equipped for 90 lbs. water working pressure. boder-bumer unit number STEAM WATER ` 4' frow teBsR l=BsR burner output capacity Mbh CPh irwtlr l=R ratine Hft ataam Mbh nat ratine sq ft water chimnay size unjacketed l.ckated Trada Plica approx. Trada Price approx. with atandird shipping with etanderd ahipplnc equipment weight equipment weight A-705-S0-B A-.706-SO-B A-707-S0-B A-708-SO-B A-709-SO-B A-710-SO-B A-711-SO-B A-712-SO-B A-705-WO-B A-706-WO-B A-707-WO-B A-708-WO-B A-709-WO-B A-710-W0-B A-711-WO-B A-712-WO-B 865 1012 1196 1376 1570 1760 1956 2148 8.15 9.55 11.25 12.90 14.65 16.30 18.00 19.65 27073163 3738 4340 5013 5672 6328 6949 649.7 759.2 897.2 1041,6 1203.1 1361.2 1518.6 1667.7 4331 5061 5981 6944 8020 9075 10125 11118 16 x 16x28 16 x 16 x 30 16 x 20 x 36 16 x 20 x 42 16 x 20 x 45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 $1571.00 1685.00 1852.00 2191.00 2336.00 2505.00 2694.00 2856.00 4231 4883 5532 6283 6919 7603 8195 8871 $1652.00 1771.00 1950.00 2307.00 2474.00 2651.00 2850.00 3023.00 4403 5058 5715 6492 7134 7822 8456 9169 "Nozzle sizes, gph. 80*S, furnished with A-7 units ere es follows: A-705. 2 4.00: A-706, 1 4.S0, 1 5.00; A-707, 2 5.50; A-708 1 4.00. 2 4.50; A-709. 1 4.50. 2 5.00; A-710. 1 5.00. 2 5.50; A-7U. 3 6.00; A-712. 3 6.50. Standard equipment: (see options, next page) 96- 7508 oU burner for A-705. A-706, A-707. 97- 7606 oil burner for A-708, A-709. A-710. 98- 7706 oil burner for A-711, A-712. All with pedestal mounting; two-stage fuel unit; electronic flame safeguard control consisting of C7013A photocell installed in burner. On model 96-7508 burner, Q270A safety switch base is mounted on burner housing. On models 97-7606 and 98-7706, W415B1 panel is furnished with Q270A safety switch base and R488E load relay. On all three models, RA890E safety switch is packed with burner; delayed oil valve in stalled between fuel unit and drawer assembly. Draft stabilizer. Steel pedestal base in addition to regular 12' base; 8' height for 5 through 7 section; 10' height for 8 through 12 section. Steam only: No. 11 Arcoflame control set (CA-520 thermostat, 450-BA-l pressure limit control) and nozzles. Steam gauge, ASME safety valve, gauge glass and trimmings. Water only: No. 13 Arcoflame control set (CA-520 thermostat, CA-655 immersion limit control) and nozzles. Theraltimeter and ASME relief valve for 50 lbs. Combustion chamber not furnished. See Installation-Operation and Maintenance Man ual for combustion chambers for A-7 boiler-burner units. A-7 OIL FIRED BOILERS Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure. boiler number STEAM WATER A-705-SO A-706-SO A-707-SO A-708-SO A-709-SO A-710SO A-711-SO A-712-S0 A-705-WO A-706-WO A-707-WO A-708-WO A-709-W0 A-710-WO A-711-WO A-712-WO croaa IsBsR I=B=R burner output capacity Mbh SPh net Is B=R rating sq ft ataam Mbh nat rating aq ft water 866 1012 1196 1376 1570 1760 1956 2148 8.15 9.55 11.25 12.90 14.65 16.30 18.00 19.65 2707 3163 3738 4340 5013 5672 6328 6949 649.7 759.2 897.2 1041.6 1203.1 1361.2 1518.6 1667.7 4331 5061 5981 6944 8020 9075 10125 11118 chimney aixe unjacketed lacketed approx. approx. Trade Price shipping Trad. Price shipping weight weight 16 x 16x28 16 x 16x30 16 x 20 x 36 16 x 20 x 42 16x20x45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 $1200.00 1314.00 1481.00 1643.00 1788.00 1957.00 2121.00 2283.00 3882 4518 5149 5720 6330 6990 7556 8208 $1281.00 1400.00 1579.00 1759.00 1926.00 2103.00 2277.00 2450.00 4054 4693 5332 5929 6545 7209 7817 8506 Standard equipment: (see options, next page) Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water: Theraltimeter and ASME relief valve for 50 lbs. Tor complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-2 pa28 04557 AMERiCAN-<$taitdard HYDRONICHE AT INO A-7 OPTIONAL EQUIPMENT BOILER-BURNER UNITS OIL FIRED BOILERS 1T1AM AND WATIl BGiLtK-bURNER UNITS only: Arcoflame control sets other than those Included in Trade Price of boiler-burner units will be furnished when specified on order at the following added charges: Control Set Added Charge Steam control set No. 12....................................................................... $13.30 Water control set No. 15...................................................................... 22.75 Water control set No. 16...................................................................... 24.40 Water control set No. 16-Z.................................................................. 53.20 Water control set No. 26 ...................................................................... 24.40 Water control set No. 33...................................................................... 5.90 Detailed description of Arcoflame control sets is shown on page 32. Electronic flame safeguard equipment: For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Laboratories, Inc., oil burners are available with special electronic flame safeguard controls for A-7 boiler-burner units as follows: 96- 7509 oil burner for A-705, A-706 and A-707 boiler-burner units at added Trade Price charge of $30.00. 97- 7607 oil burner for A-708, A-709 and A-710 boiler-burner units, and 98-7707 for A-711 and A-712 boiler-burner units at added Trade Price charge of $13.50. 450-BC-l vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam units-see page 31 for added charge. Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30. BOILER-BURNER UNITS or OIL FIRED BOILERS: Water mixing valves: for prices see page 32. McDonnell-Miller No. 47-2 and No. 51-2 low water cut-off and feeder combinations: No. 47-2 used with A-705 through A-707 and No. 51-2 used with balance of sizes. Special equalizer tap ping for bottom connection of No. 51-2 located 6 inches below water line on front section. Specify No. 47-2 or No. 51-2 on order and add to Trade Price of steam boilers with standard equipment Trade Price for these items shown in the current McDonnell-Miller price sheet. For No. 369 low water cut-off for use with steam units, see page 32. OIL FIRED BOILERS only: Steel pedestal bases for installation under the regularly furnished 12" base for greater base heights will be furnished when specified on order at the following added charges: taction tin 5 through 7 8 through 12 bait height 8" 10" added charge $44.00 72.00 Page 29 04558 HH-2 OIL BURNERS ZONE CONTROL SETS American-^Standard HYDRONIC HEATING OIL BURNERS for 115 volt, 60 cycle current For Arcoleoder, Arcoliner, Oakmont, Severn, A-5 and A-7 boilerburner unite Model 96-7508 model number capacity gal. par hour air tuba length dlam. mounting including CA-701 primary control DH-5 ,65- 3.00 5 4 sling DH-6 .65- 3.00 6 4 sling 45W-3606 3.00- 4.00 7y. 4V flange 62A-7056 4.00- 7.00 10V4 6Vs flange 62A-7056 4.00- 7.00 10V6 6VL flange Including electronic flame safeguard control 96-7506 6.00-12.00 10*/8 6V6 96-7508 6.00-12.00 10V6 6% 97-7606 10.00-17.00 10`/ 7 98-7706 14.00-20.00 ioy 8 flange pedestal pedestal pedestal Trado Prico approx. hipping weight $115.15 115.15 159.00 175.00 180.00 55 55 56 77 82 290.00 327.00 476.00 501.00 107 145 208 208 62A-7056 burner supplied with 9" draft stabilizer for A-507 and A-508, and with 12' draft stabilizer for A-509 boilerburner units. DH-5 burner for Arcoleader, Arcoliner and Oakmont boilerburner units is shipped with pressure ring only. CA-701 pri mary control is shipped installed with Arcoleader Packaged units and is a separate shipping component with Arcoleader, Arcoliner and Oakmont boiler-burner units. DH-5 burner for A-504 boiler-burner unit is shipped with CA-701 primary control and mounting accessories. DH-6 burner for Severn boiler-burner units is shipped with CA-701 primary control. Accessories for Severn are shipped in a separate box. 45W-3606 and 62A-7056 burners for A-505 through A-509 boiler-burner units are shipped with CA-701 primary control and mounting accessories. 96-7506 burner for A-510 and A-511, and 96-7508 burner for A-705 through A-707 boiler-burner units are shipped with electronic flame safeguard control consisting of C7013A photo cell installed in burner. Q270A safety switch base mounted on burner housing, RA890E safety switch packed with burner. For optional control sets and added charges, see page 32. OPTIONAL ELECTRONIC FLAME SAFEGUARD CON TROL EQUIPMENT: 62A-7056F burner with electronic flame safeguard control is available instead of 62A-7056 burner for A-507, A-508 and A-509 boiler-burner units at added Trade Price charge of $93.00. The electronic control consists of C7013A photocell in stalled in burner, Q270A safety switch base mounted on burner housing. RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly. For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Laboratories, Inc., oil burners are avail able with special electronic flame safeguard controls for boiler-burner units as follows: 62A-7056FFM burner for A-507, A-508 and A-509 boilerburner units at added Trade Price charge of $133.00. 96-7507 burner for A-510 and A-511 boiler-burner units. 96-7509 burner for A-705, A-706 and A-707 boiler-burner units at added Trade Price charge of $30.00. 97-7607 burner for A-708, A-709 and A-710 boiler-burner units, 98-7707 burner for A-711 and A-712 boiler-burner units, at added Trade Price charge of $13.50. 97-7606 and 98-7706 burners for A-708 through A-712 boilerbumer units are shipped with electronic flame safeguard con trol consisting of C7013A photocell installed in burner. W415B1 panel furnished with Q270A safety switch base and R488E load relay; RA890E safety switch packed with burner. The above prices are for oil burners with primary control as shown. No. 11 steam or No. 13 water basic control set with CA-520 thermostat, and nozzle (s). Two-stage fuel unit is available for DH oil burners at $5.00 Trade Price extra. Two-Stage fuel unit is regularly furnished with 45W, 62A, 96, 97 and 98 oil burners. Delayed oil valve is standard on all the above burners with electronic controls. V4001A valve installed is available on 45W and 62A burners at $13.00 Trade Price extra. ZONE CONTROL SETS: Using Hydronic Zone Valves Two-zone and three-zone control sets utilize one CA-520 thermostat furnished with Packaged G-2 Gas Boilers and Arcoleader Packaged boiler-burner units. When these sets are to be used with other forced hot water installations using circulator, it will be necessary to secure an additional CA-520 thermostat to control the first zone Sat No. 2-Z For Two Ion-- Sat No. 3`Z For Three Zones Set No. 4-Z For Each Zone in Addition to Three Zones Contents of Sat No. 2*2: 1 CA-520 Round Thermostat 2 V8031B *4" sweat M-H Zone Valves 1 40VA Transformer Contents of Set No- 3-Z: 2 CA-520 Round Thermostats 3 V8031B *4" sweat M-H ^one Valves 1 40VA Transformer Contents of Add-on Set No. 4-Z: l CA-520 Round Thermostat 1 V8031B sweat M-H Zone Valve 1 40VA Transformer Trade Price 545.19 Trede Price $70.67 Trade Price $27.45 HH-2 Pago 30 04559 American-cStandard\ H YDRONIC HE AT IN Oh OIL BURNERS for ITS volt60 cycle current For conversion and replacement model number capacity gal. per hour air tuba length diam. mounting (specify If pedestal or flange Is wanted for DH and S2A burners.) including CA-701 primary control DH-8 DH-15 DH-23 .65-3.00 .65-3.00 .65-3.00 8 15 23 52A 62-1-7000 3.00-4.00 4.00-7.00 73/i or 10% 16% 4 pedestal 4 4 ' or ' 4% flange 6 % pedestal NOTE: Optional air tube length* are available for 52A burner. Add to Trade Price for Trade Price with control set with primary control and nozzle!*) only approx, ship, volgfati Wttfl control set with primary control and nozzle(t) only $115.15 117.15 118.15 155.00 170.00 $100.50 102.50 103.50 139.00 154.00 60 65 65 65 73 length $3.50: for 22*/" length $5.50. 55 60 60 60 66 including electronic flame safeguard control 62-2-7002 96-7501 97-7601 98-7701 5.00- 8.00 6.00-12.00 10.00-17.00 14.00-20.00 16% 16% 16% 16% 6% pedestal 275.00 259.00 83 80 6% pedestal 290.00 274.00 91 88 7 pedestal 476.00 460.00 168 165 8 pedestal 501.00 485.00 168 165 The above prices for burners with control set include primary control as shown; No. 11 steam. No. 13 or No. 14 water, or No. 19 warm air control set with CA-520 thermostat, as speci fied on order. For optional control sets and added charges, see page 32. For burners shown above with primary control and nozzle(s) only, additional controls are available at Trade Prices shown on page 32. DH-8, DH-15. DH-23, 52A and 62-1-7000 burners are furnished with CA-701 intermittent ignition primary control. On models with electronic flame safeguard controls, C7013A photocell is installed on burner. On 62-2-7002 and 96-7501, Q270A safety switch base is mounted on burner housing. On 97-7601 and 98-7701, W415B1 panel is furnished with Q270A safety switch base and R488E load relay. On these models, RA890E safety switch is packed with burner; delayed oil valve is installed between fuel unit and drawer assembly. P52A-4322F burner is available with electronic flame safe guard control consisting of C7013A photocell installed in burner, Q270A safety switch base mounted on burner housing and RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly at $93.00 addition to Trade Price of 52A burner. OPTIONAL ELECTRONIC FLAME SAFEGUARD CON TROL EQUIPMENT For installations with firing rates above 4.00 gph requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Labora tories, Inc., oil burners are available with special electronic flame safeguard controls as follows: 62-2-7003 burner at $30.00 addition to Trade Price of model 62-2-7002. 96-7502 burner at $30.00 addition to Trade Price of model 96-7501. 97-7602 or 98-7702 burner at $13.50 addition to Trade Price of models 97-7601 and 98-7701. Two-stage fuel unit is available for DH oil burner at $5.00 Trade Price extra. Two-stage fuel unit is standard on 52A, 62, 96, 97 and 98 oil burners. Delayed oil valve is standard on all the above burners with electronic controls. V4001A oil valve installed on 52A and 62-1-7000 burners is available at $13.00 Trade Price extra. When ordering oil burners be sure to specify nozzle sizes wanted. One nozzle is furnished with DH, two nozzles with 52A, 62, 96 and 97, and throe nozzles with 98 oil burners. Nozzles and strainers are as follows; For DH: Hollow cone, 60* or 70*, 0.65-1.25 gph. Solid cone, 60* or 70*. 1.35-3.00 gph. For 52A, 62, 96, 97 and 98: Solid cone, 70', 1.50-2.00 gph; 80', 2.25-6.50 gph. Vapor Installations: Substitute 450-BC-l vapor limit control for 450-BA-l pressure limit control with No. 11 or No. 12 con trol sets and add $10.99 to Trade Price. Electric Clock Thermostat: Substitute T852A for CA-520 ther mostat; specify on order control set number with suffix "B". and add $27.17 to Trade Price. Substitute C8-580 for CA-520 thermostat: Deduct $2.83 from Trade Price with control set shown above. Perfxray Primary Controls Models DH-8, DH-15 and DH-23 conversion and replacement Arcoflame oil burners are available with Perfxray primary control set consisting of CT-99 flame detector factory mounted in air tube, and R-96 programming relay (for jacket mounting only) shipped with burner. Trade prices for burners with constant ignition are the same as shown above either with control set or with primary control and nozzle. If intermittent ignition is wanted specify on order and add $2.00 to the above Trade Prices. Arcoflame oil burners are approved by the National Board of Fire Underwriters and comply with Commercial Standard CS-75, Capacities of Arcoflame oil burners are for installations at sea level and at elevations up to 1,000 feet. Reduce by 4% for each additional 1,000 feet above sea level. For discount on repairs, see pape 2. Page 31 04560 H H-2 OIL BURNER CONTROL SETS AMERICAN-^tandatd CONTROLS HYDRONIC HEATING control Mt for: contents of Arcoflame control sat number description add to Trade Price of oil burner with basic control ast No. n Steam No. 12 Stnm No. 13 Water No. 14 Water No. IS Water No. 16 Water No. 16-Z Water No. 19 Warm Air No. 20 Warm Air No. 26 Water No. 33 Water No. 36 Water No. 36-Z Water Boiler without domestic hot water. Boiler with year-round domestic hot water, built-in heater. Boiler without domestic hot water, im mersion control. Boiler without domestic hot water, clamp-on control. Boiler with year-round domestic hot water, storage tank heater, using cir culator. Boiler with year-round domestic hot water, built-in tankless heater, using circulator. 2-Zone control, for boiler with yearround domestic hot water, built-in tankless heater, using circulators. Note: For each additional zone, add 1 CA-520 thermostat and 1 CA-262 relay transformer at current prices. Gravity furnace. Forced warm air unit. Boiler with year-round domestic hot water, built-in tankless heater, using circulator. Boiler without domestic hot water, constant circulator operation. Arcoleadar and A-5 units ONLY with year-round domestic hot water, builtin tankless heater, using circulator. Arcoleadar and A-5 unite ONLY. (1 No. 36-Z set is required for each zone in addition to the hrst zone which is controlled by the No. 36 control set.) CA-520 450-8A-1 CA-520 450-BA-l CA-666 CA-520 CA-655 CA-520 251-MJ CA-520 CA-655 CA-666 CA-262 CA-520 CA-655 CA-666-DT CA-262 2 CA-520 CA-655 CA-666 CA-666-R 2 CA-262 CA-520 CA-644 CA-520 CA-640-S CA-520 CA-655 CA-666-AD CA-262 CA-520 CB-614 CA-520 CA-610 CA-520 CA-260 thermostat limit control thermostat limit control 1mm. operating control 513.30 thermostat limit control thermostat limit control thermostat limit control imm. operating control relay transformer 522.75 thermostat limit control imm. control double throw switct relay transformer 524.40 thermostats limit control imm. operating control rev. acting low limit control relay transformers 553.20 thermostat limit control thermostat fan and limit control $ 1.35 thermostat Limit control imm. control double throw switch, adj. differential relay transformer 524.40 thermostat high limit rev. act. control 5 5.90 thermostat imm. control relay combination 515-05 thermostat zone control relay Add-on zone (Use only with No. 36 set) 520.35 Controls - Regularly furnished are for 115 volt 60 cycle current number description Trade Price number description Trade Price CA-520 C8-580 CA-440 AMERICAN-STANDARD thermostat. ROUND, low voltage thermostat, low voltage thermostat, line voltage $ 7.74 4.91 13.50 251-MJ CA-260 CA-262 clamp-on water limit control zone control relay relay transformer 8.03 12.60 12.60 450-BA-l 4 50-BC1 CA-6JO pressure limit control. 0-10 lbs. vapor limit control, 0-3*,fe lbs. immersion control relay combination 11.59 22.58 23.48 CB-614 CA-655 CA-666 high limit reverse acting control immersion limit control immersion operating control 14.36 8.44 10.13 CA-666R CA-666 0T reverse acting low limit control imm. hot water control, double throw switch 10.13 11.81 CA-666-AD CA-701 CA-704 AMERICAN-STANDARO imm. hot water control double throw switch. adjustable differential primary control, intermittent ignition primary control, constant ignition 511.81 27.30 25.80 CA-840-S CA-844 RS-116-F CB-520100 fan and limit control warm air limit control immersion control relay combination mounting cover plate 9.77 8.36 24.90 .45 T-80A GENERAL CONTROLS thermostat for self-energizing application 5.21 T86A T832A T852A thermostat, low voltage thermostat, low voltage, manual turn-down thermostat, electric clock 7.80 20.96 34.91 Vernatherm water mixing valves number description size Trade Price number description size Trade Price VD-203 VD-205 adjustable non-adjustable /i%>/j/.- 511.48 12.06 7.92 8.32 VD-206 VD-208 - adjustable non-adjustable Va* nom. sweat x/i0 nom. sweat 5 7.35 6.68 No. 369 McDonnell a Miller low water cut-off for automatically fired steam Arcoliner. Oaicmont, Severn. Exbrook. A-5 and A-7 boilers and/ or boiler-burner units....................................................................................................... ..................................................................... Trade Price each $16.75 HH-2 Page 32 04561 American-Standard HYDRONIC HEATING STOKER FIRED BOILERS JTIAM AMO WATI* SEVERN STOKER FIRED BOILERS Flush jacket. boHr number grot* CTF4U WATFR output Uhh ________________ J _________ firing rate pound* per iiuui net Jnetafied rating *?.* 1 Mbh 1- ____ 1_______________ q ft w.Uf Not adapted for Built-in Water Heater ( see options below) Trade Price appro*. shipping weight SC17 SC-21 SC-25 SC-29 SC-33 SC-37 WC-17 WC-21 WC-25 WC-29 WC-33 WC-37 146 16 456 109.5 730 $338.00 1053 168 18 525 126.0 840 376.00 1220 188 21 588 141.0 940 413.00 1301 216 24 675 162.0 1080 454.00 1457 247 27 772 185.3 1235 513.00 1534 278 31 869 208.6 1390 569.00 1687 Standard Equipment: Steam: Steam gauge. ASME safety valye. gauge glass and trimmings. Water: Theraltimeter and ASME relief valve. Optional equipment: Boilers arranged for but less Built-in heaters: If desired, for use with heaters No 590. 594 and 595, add suffix letter "T" to boiler number and add $6.00 to Trade Price of boiler with standard equipment. If 2V4" right or left side tapping in back section for Built-in heater No. 703 is desired, specify on order and add $2.00 to Trade Price of boiler. Water mixing valves: for prices, see page 32. For low water cut-off for use with steam Severn boilers, see page 32. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at an added Trade Price charge of $3.70. Below are the ratings and Trade Prices tor Built-in heaters available for Severn stoker boilers. For detailed information on ratings, see page 2. Heater No. 703 594 595 590 Heater Type tank tank tank tankless Heater Rating* gals, capacity 66 100 160 3>/2 per minute Trade Price $ 9.00 48.00 42.50 36.00 approx. shipping weight 7 54 51 60 EXBROOK STOKER FIRED BOILERS boiler number STEAM WATER gross_ output Mbh l=Bs R burner capacity Ibs/hr net l=B =R rating sq ft steam Mbh B net sq ft water Trade Price size Not adapted for Built-in Water Heater (see options below) SC-207 SC-208 SC-209 SC-2010 SC-2011 SC-2012 SC-2013 WC-207 WC-208 WC-209 WC-2010 WC-201I WC-2012 WC-2013 276 30 863 207.1 1380 $575.00 8x12x25 335 37 1047 251.3 1675 651.00 8x12x25 396 43 1238 297.1 1980 731.00 12x12x30 452 50 1413 339.1 2261 803.00 12x12x30 508 56 1588 381.1 2541 873.00 12x12x35 564 62 1763 423.1 2821 947.00 12x16x40 620 68 1938 465.1 3101 1013.00 12x16x40 Standard Equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water: Theraltimeter and ASME relief valve. approx. shipping weight 2150 2313 2628 2821 3134 3309 3641 Optional equipment: Boilers arranged for but less Built-in heater: If desired add suffix letter "T" to boiler and add $6.00 to Trade Price of boiler with standard equipment. Built-in water heaters are available for use with Exbrook "T" type boilers only. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $4 25. For low water cut-off for Exbrook steam boilers, see page 32. Below are the ratings and Trade Prices for Built-in heaters available for Exbrook "T" type Stoker boilers For detailed information on ratings, see page 2. Heater No. 591 592 Heater Type tank tank Heater Ratings gals, capacity 120 200 Trade Price $32.50 46.50 approx. shipping weight 35 53 For complete information on boiler ratings, see page 2 For discount on repairs, see page 2. Page 33 HH-2 04562 STOKER FIRED BOILERS fUMi AMD WATft A/MiBicAN-^taitdaifd HYDRONIC HEATING boiler number STEAM WATER 3SC-8 3-SC-9 3-WC-8 3-WC-9 grots output Mbh 706 798 NO. 3 REDFLASH STOKER FIRED BOILERS Jacketed and unjacketed. firing rats pounds per hour 78 88 9 nst Installed rating sq ft steam Mbh sqft water 2207 2494 529.6 598.6 3531 3991 unjackstad Trade Price approx. shipping weight $1076.00 1195.00 3652 4041 Jacketed Trade Price approx. shipping weight $1164.00 1286.00 3827 4224 Standard equipment: Steam: Steam gauge, ASMS safety valve, gauge glass and trimmings. Water Theraltimeter and ASMS relief valve. Optional equipment: External water heater tappings available at following added charges: Jacket-$2.00 per tapping. Sections-|2.00 per tapping. A-7 STOKER FIRED BOILERS Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure. boiler number STEAM WATER gross l=B=R output Mbh 1=B=R bumsr capacity Ibs/hr nat l=B =R rating sq ft staam Mbh nat rating sq ft watsr chimney size unjsckstsd Trade Price approx. shipping weight Jacketed Trade Price approx. shipping weight A-705-SC A-705-WC A-706-SC A-706-WC A-707-SC A-707WC A-708-SC A-708-WC 866 1012 1196 1376 95 2707 649.7 111 3163 759.2 131 3738 897.2 151 4340 1041.6 4331 5061 5981 6944 16 x 16x28 16 x 16 x 30 16 x 20 x 36 16 x 20 x 42 $1200.00 1314.00 1481.00 1643.00 3882 4518 5149 5720 $1281.00 1400.00 1579.00 1759.00 4054 4693 5332 5929 A-709-SC A-710-SC A-711-SC A-712-SC A-709-WC A-710WC A-711-WC A-712-WC 1570 1760 1956 2148 172 5013 1203.1 8020 16 x 20 x 45 1788.00 6330 1926.00 6545 194 5672 1361.2 9075 20 x 20 x 50 1957.00 6990 2103.00 7209 215 6328 1518.6 10125 20 x 20 x 55 2121.00 7556 2277.00 7817 236 6949 1667.7 11118 20 x 20 x 60 2283.00 8208 2450.00 8506 Standard Equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water Theraltimeter and ASME relief valve for 50 lbs. Optional equipment: Steel pedestal bases for installation under the regularly fur nished 12' base for greater base heights will be furnished when specified on order at the following added charges: section size 5 thru 7 8 thru 12 bate heights 8" 10" added charge *44.00 72.00 For low water cut-off for A-7 steam boilers, see page 32. a For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-2 Pase 34 04563 STEAM boiler number WATER S-153-D S-154-D S-155-D W-153-D W-154-D W-155-D AMERicAN-<Standard HYDRONIC HEATING ARCOLINER HAND FIRED Factory assembled sections. Dry base construction. Flush jacket. BOILERS HANDFIb^B6rttKs gross output Mbh sq ft steam n*t Install**! rating Mbh q ft water Trad* Price approx. shipping weight 102 180 43.2 288 $286.00 771 152 272 65.3 435 334.00 928 204 373 89.4 596 384.00 1083 Standard Equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve. Built-In Heaters: If Front Section arranged for but less Built-in screw-in heaters No. 701 or 702 is desired specify on order. Below are the ratings and Trade Prices of Built-in heaters available for Arcoliner Dry Base steam boilers. For detailed information of ratings, see page 2. Haatar No. Haatar Typo Haatar ratings gals, capacity Trad* Pries approx. shipping weight 701 tank 60 $8.50 5 702 tank 40 8.00 4 Note Built-in water heaters are not recommended for hand fired water boilers. STEAM boiler number WATER S-17 S-21 S-25 S-29 S-33 S-37 W-17 W-21 W-25 W-29 W-33 W-37 SEVERN HAND FIRED BOILERS Flush jacket. gross output Mbh sq ft steam a net installed rating Mbh tq ft water Trade Price approx. shipping weight 194 244 296 328 364 396 353 84.7 453 108.7 553 132.7 630 151.3 710 170.5 783 187.9 565 725 885 1009 1137 1253 $374.00 432.00 494.00 544.00 599.00 646.00 1243 1413 1521 1686 1783 1956 Standard Equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve. Built-in Heaters: If 2%" right or left side tapping in back section for Built-in screw-in heaters No. 701, 702 or 703 is desired specify on order and add $2.00 per tapping to Trade Price of boiler. Below are the ratings and Trade Prices of Built-in heaters available for Severn hand fired steam boilers. For detailed information on ratings, see page 2. Heater No. Heeter Typo Heeter retina gals, capacity Trade Price approx. shipping weight 701 tank 60 $8.50 702 tank 40 8.00 703 tank 100 9.00 Not*: Built-in water heaters are not recommended for hand fired water boilers. 5 4 7 For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Pig* 35 HH-2 04564 . HAND FIRED BOILERS ITtAJM AMO WATER STEAM 2-S-6 2S-7 2-S-8 2-S-9 2S-10 2-S-l 1 2-S-12 boiler number WATER 2-W-6 2-W-7 2-W-8 2-W-9 2-W-10 2-W-ll 2W-12 American-^Standard HYDRONIC HEATING NO. 2 REDFLASH HAND FIRED BOILERS Jacketed and unjacketed. grot* output Mbh net Installed ratine sq ft itum Mbh q ft water unjackeied Trade Price 390 464 536 606 676 744 812 769 940 1111 1281 1453 1623 1794 184.7 225.7 266.7 307.5 348.8 389.5 430.5 1231 1505 1778 2050 2325 2597 2870 $ 596.00 673.00 749.00 821.00 892.00 965.00 1041.00 1966 2293 2466 2782 2999 3313 3503 ih sn Trade Price $ 657.00 737.00 817.00 893.00 969.00 1045.00 1124.00 approx. shipping weight 2091 2390 2572 2897 3122 3446 3644 Standard Equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve. boiler number STEAM WATER 3-S6 3-S-7 3-S-8 3-S-9 3-W-6 3-W-7 3-W-8 3-W-9 NO. 3 REDFLASH HAND FIRED BOILERS Jacketed and unjacketed. gross output Mbh 696 814 932 1046 net installed rating sq ft steam Mbh sq ft water 1503 1799 2100 2400 360.6 431.8 504.1 576.0 2404 2879 3360 3840 un|acketed Trade Price approx. shipping weight $ 912.00 1046.00 1184.00 1324.00 3243 3698 4110 4549 jacketed Trade Price approx. shipping weight $ 988.00 1127.00 1272.00 1415.00 3397 3870 4285 4732 Standard Equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. Water Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve. Note Buckwheat coal grate bars will be furnished at no additional charge when specified on order. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-2 Pag* 36 04565 American'^Standard HYDRONIC HEAT J N Q A-7 HAND FIRED BOILERS `j~r Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure boiler number STEAM WATER A-705-S A-705W A-706-S A-706-W A-707 S A-707-W A-708S A-708-W A-709-S A-709-W A-710S A-710-W A-711-S A-711-W A-712S A-712W gross l=B=:R output Mbh net l=B=R sq ft steem Mbh 1122 1298 1510 1708 1910 2108 2288 2456 2606 3101 3725 4342 5008 5681 6326 6947 625.4 744.3 894.0 1042.1 1202.0 1363.5 1518.2 1667.3 net rating sq ft water chimney size 4169 16 x 16 x 40 4962 16 x 20 x 45 5960 20 x 20 x 50 6947 20 x 20 x 55 8013 20 x 20 x 60 9090 20 x 24 x 65 10122 20 x 24 x 70 11115 24 x 24 x 75 unfacke led Trade Price approx. shipping weight jacketed Trade Price approx. shipping weight $1327.00 1447.00 1615.00 1788.00 1910.00 4294 5006 5738 6392 7199 $1408.00 1533.00 1713.00 1904.00 2048.00 4466 5181 5921 6601 7334 2061.00 7858 2207.00 8077 2225.00 8506 2381.00 8767 2377.00 9231 2544.00 9529 Standard equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. Water: Theraltimeter and ASME relief valve for 50 lbs., automatic damper regulator and firing tools. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Pag# 37 C4566 HH-2 RADIATORS Ame rican-<S>tandard HYDRONIC HEATING ARCO RADIATORS width 6 tube 3 tube 4, 5, 6 tube 4, 5 tube 4, 6 tube height Inches 32 25 25 22 19 Trade Price per sq ft (1.19 1.19 1.12 1.17 1.19 Three, four, five and six tube Arco Radiators are regularly furnished with two and one-half inch (2 Vi") legs but can be supplied on Special Order with four and one-half inch (4H-) legs, or without legs, at no extra charge. Arco Radiators sold only in even number of sections up to a maximum of 56 sections. SUNRAD RADIATORS type Trade Price per sq ft M 5x20 M 7i/2 x 23 $1.42 1.49 M 5 x 20 and M 7V4 x 23 Sunrad Radiators are regularly fur nished with two and three-quarter inch <2%") legs but can be supplied on special order without legs, at no extra charge. Sunrad Radiators sold in even number of sections from 4 to 30 sections, and in odd number of sections with center leg from 31 to a maximum of 45 sections. PEERLESS WALL RADIATORS type Trade Price per sq ft 11-B Pattern 8-B Pattern $1.28 1.34 Extra charge of $0.60 each will be made for tappings at Nos. 20, SO, 60 and 90 as shown on outline drawings of Peerless Wall and Ceiling Radiators in current literature. Radiators furnished per Figures 840 or 1140 add $2.40 trade extra Radiators furnished per Figures 842 or 1142 add $4.80 trade extra For convenience in handling and shipping, Nos. 8-B and 11-B Radiators will be assembled in lengths not exceeding 4 sections. height In Inches 32 25 22 19 RATINGS - SQUARE FEET PER SECTION Arco Radiators Sold only in even number of sections 3 tube sq ft per section 4 tube 5 tube CO H 1.6 2.0 2.4 2.1 1.6 6 tube 3.7 3.0 2.3 Peerless Wall Radiators 1 I B Pattern.................................................. 11 sq ft per section 8-B Pattern.................................................. 8 sq ft per section 'Sunrad Radiators M 5 x 20 Pattern........................................2.25 sq ft per section M 7>/2 x 23 Pattern................................... 3.40 sq ft per section `Important: Increase size 5% for recessed Installation--*4" air space top and sides. Vt" at back. Increase size 15% for tightly recessed In- steilation--no clearance top or sides. air space at back. HH-2 Paga 38 04567 American-Standard HYDRONIC HEATING BASEBOARD PANELS RADIATOR ACCESSORIES RADIATOR ACCESSORIES Arco Bracket*: For 3, 4, 5. 6 tube, with Wall Plate............................... Arco Radiator Pedestal*: `A* and X"....................................................................... iVi" ................................................................................... Sunrad Brackets: For M5 x 20 and M7>/2 x 23........................................ Peerless Wall and Celling Brackets: Adjustable, with Bearing Plate,single spool.............. Adjustable, with Bearing Plate,double spool............. TypeL .............................................................................. Type M .............................................................................. Type MM ......................................................................... Type P .............................................................................. Trad* Wei *ch $0.79 0.30 0.39 0.62 3.B5 6.99 0.22 0.15 0.22 0.47 NippJec. Plug*. Rn*hlrgr Trade Prlca ttrh Vi". 1", 1V*", ll/z" Plugs, Bushings.......................... Vi". 1", 1V4" Slip Nipples............................................. 1 VS" Hexagon Nipples.................................................. Vi" Air Vent Plugs......................................................... Radiator Rod Nuts........................................................... Radiator Rods............................................... per section $0.22 0.22 0.39 0.01 0.01 0.01 Abova Items available for ua only with our Radiator products. Sunrad Grilles Inlet--Stamped Lattice Type............................................per section SO.18 SHIPPING WEIGHTS For estimating purposes only, the following approximate weights per square foot may be used tor radiators: Arco. 444 pounds; Sunrad, M5 x 20-6 pounds, U7H x 23--644 pounds; Peerless Wall, 644 pounds; New Model 8 Radiantrim Panels: 444 pounds per square foot, 12.16 pounds per lineal foot; Model 10 Radiantrim Panels: 444 pounds per square foot, 16.15 pounds per lineal foot. For estimating purposes only, the following approximate shipping weights may be used for Convectors and Cabinets: Arco Convectors-elements only-see page 45. Complete Cabinets, for Arco or Multifln Convectors, per sq ft of cabinet output-144 pounds. Multifin Convectors-elements only-see page 42. Multifln Units (convectors shipped mounted in cabinets) per sq ft of cabinet output- ``Spacial Service Une'* Types F, R, RC-1% pounds. Type W-144 pounds. Type FS -144 pounds. Type S -144 pounds. "Stock Model"-1.13 pounds; also see pages 43 and 44. Heatrim Panels see pages 40 and 41. l = B=R Steam Rating per lineal foot 2.75 sq ft per lineal foot per square foot Trade Price* $3.06 $1.12 New Model 8 Radiantrim Panel lengths (244 ft to 30 ft) are made up from the following sections: 144 ft Left hand end section 1 ft Right hand end section 2 ft Left hand end section 2 ft Right hand end section 2 ft Center section Assembly length with legs and tappings at each end: 2 ft Double end section l=B=R Steam Rating per lineal foot 3.4 sq ft per lineal foot per square foot Trade Price- $3.81 $1.12 Model 10 Radiantrim Panel lengths (244 ft to 30 ft) are made up from the following sections: 144 ft Left hand end section 1 ft Right hand end section 2 ft Left hand end section 2 ft Right hand end section 2 ft Center section Assembly length with legs and tappings at each end: 144 ft Double end section 2 ft Double end section New Model 8 Accessories prfo Extension Panel and Brackets (Two 6 ft lengths per box) ...................................... $8.40 Extension Panel Retaining Bracket............................ 0.22 Extension Panel Cover Strip........................................ 0.53 Assembly Clamp .............................................................. 7.70 Compression Corner Connection ................................ 2.40 Retaining Block ................................................................ 0.15 Adjustable Leg .................................................................. 0.20 Tie Bolt ............................................................................... 0.06 These items ere regularly furnished as required with New Model 8 Radtantrim Panels end Accessories. Prices are shown for repair or re placement purposes. Packed In quantity of 10 per box (Available only in this minimum quantity) Inverted Comer Cover............................................ Extended Inverted Comer Cover.......................... Projecting Comer Cover........................................ Valve Enclosure (all R.H. or L.H.) .................... End Box (all R.H. or L.H.) .............................. Trade Price per box of 10 $10.50 17.50 14.20 12.35 7.00 Model 10 Accessories price Extension Panel and Brackets (Two 6 ft lengths per box) . ....................................... $13.10 Extension Panel Retaining Bracket............................ 0.22 Extension Panel Cover Strip........................................ 0.53 Assembly Clamp ............................................................... 7.70 Compression Corner Connection.................................. 2.40 Retaining Block ............................................................... 0.15 Adjustable Leg ................................................................. 0.20 Tie Bolt ............................................................................... 0.06 These items are regularly furnished as reouired with Mode! 10 Ra diantnm Panels and Accessories. Prices are shown for repair or re placement purposes. Packed in quantity of 10 per box (Available only in this minimum quantity) Inverted Comer Cover ................. Extended Inverted Comer Cover Projecting Corner Cover .............. Valve Enclosure (aU R.H. or L.H.) End Box (all R.H. or L.H.) .......... Trade Price per box of 10 ..$13.10 . 23.60 .. 16.60 .. 18.35 9.80 Page 39 04568 HH-2 ejjuACf asAoa:?:Ai: WEATRIM-PANELS Atl- 'f AMERidAN-^tandard HYDRONIC-HtATINO SEE CURRENT LITERATURE FOR APPROVED I-B-R HOT WATER RATINGS dncriptlon approx. shipping weight Trad* Prtca COMPLETE UNITS: Model N85-L-Packaged in 3', 4\ 5'. 6', and 8' lengths-completely assembled (package contains element, one-piece back and top section, front panel, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint. ( per 3 ft. length l per 4 ft. length < per 5 ft. length 1 per 6 ft. length l per 8 ft. length *per lineal foot 9 $ 5.85 12 7.80 15 9.75 18 11.70 24 15.60 3 1.95 Model N85HH-Packaged in 3'. 4', 5-, 6'. and 8' lengths-completely assembled (package contains element, one-piece back and top section, front panel, splitter/damper, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint. f per 3 ft. length 1 per 4 ft. length ( per 5 ft. length 1 per 6 ft. length l per 8 ft.length *per lineal foot 12 7.35 16 9.80 20 12.25 24 14.70 32 19.60 4 2.45 HEATING ELEMENTS: Model N85 (4" tube)-Packaged six equal lengths per box. f per box of six 3' lengths j per box of six 4' lengths ( per box of six 5' lengths 1 per box of six 6' lengths V per box of six 8' lengths *per lineal foot Model N85 <%" tube)-Individually packaged one per box. / per box of one 3' length 1 per box of one 4' length j( per box of one 5' length per box of one 6' length l per box of one 8' length per lineal foot Model HO <1" tube)-Packaged eight 6' lengths per box. *For comparative and estimating purpoeos only. MM*2 per box of eight -per lineal foot Riga 40 18 24 30 36 48 1 3 4 5 6 8 1 79% 1% 18.00 24.00 30.00 36.00 48.00 1.00 3.21 4.28 5.35 6.42 8.56 1.07 94.08 1.96 04569 AMfewcSff-^tandartl HY'O R'O'N C H EAT1 N O HEATRIM PANEL Accessories HEATRIM BASEBOARD PANEL. ACCESSORIES ENCLOSURES; Model L-Multiple packaged in 3*. 4'. S', 6', and 8' lengths-- three equal lengths per box (package contains 3 one-piece back and top sections, 3 front panels, loose snap-in support brackets, element slide cradles and 3 sets Joining pieces). Fin ished with white prime coat of paint. Model L-Individually packaged in 3', 4', 5', 6' and 8' lengths unassembled. (Package contains one-piece back and top sec tion, front paneL loose snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint. Model HH-Multiple packaged in 3', 4', 5', 6', and 8' lengthsthree equal lengths per box (package contains 3 one-piece back and top sections. 3 front panels, 3 splitter/dampers, loose snap-in support brackets, element slide cradles and 3 Bets joining pieces). Finished with white prime coat of paint. Model HH-Individually packaged in 3', 4', 5', 6' and 8' lengths unassembled. (Package contains one-piece back and top sec tion, front paneL splitter/damper, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint. V* '-! * per box of three 3' lengths per box of three 4' lengths per box of three 5' lengths per box of three 6' lengths per box of three 8' lengths per lineal foot per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length per 8 ft. length per lineal foot per box of three 3' lengths per box of three 4' lengths per box of three 5' lengths per box of three 6' lengths per box of three 8' lengths per lineal foot per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length per 8 ft. length per lineal foot shpipprpoinx.g ,... 18 24 30 36 48 2 6 8 10 12 16 2 if* 84 3 V4 a* 17Vz 21 28 3V4 For comparative and estimating purposes only. OMcrtptlon approx. swhiaplpgihntg MODEL L ENCLOSURE ACCESSORIES: Inverted Comer Cover-one-pieee front and top section......... Inverted Comer Cover-back section only.................................. Projecting Comer Cover.................................................................. Valve Enclosure--6" wide.......................... packed all right hand< End Cover-4" wide..................................... packed all right hand< End Cap-U4" wide......................................packed all right hand< Wall End Piece-3y" wide................................................................ One-Foot Filler Pieces--14" wide................................................... Joining Pieces--2" wide...................................................................... Note: Finished with white prime coat of paint. ....... packed per box of 10 all left hand per box of 10 all left hand per box of 10 all left hand per box of 10 packed per box of 20 sets 7 5 12 15 9 5 3 15 8 Dampers for Model L Enclosures: Packaged in twelve equal lengths per box. Noto: Finished with white prime coat of paint. f per 3 ft. length per 4 ft. length < per 5 ft. length per 6 ft. length i per 8 ft. length per lineal foot Replacement parts for Model L enclosures: Enclosure fronts-8 ft. lengths only...........................................................................................each Snap-in support bracket with slide cradle............................................................................... each 12 16 20 23 32 V4 .. MODEL HH ENCLOSURE ACCESSORIES: Inverted Comer Cover-one-piece front and top section........................ packed per box of 10 Inverted Comer Cover-back section only.................................................packed per box of 10 Projecting Comer Cover................................................................................. packed per box of 10 Valve Enclosure-6" wide...........................packed all right hand or all left hand per box of 10 End Cover-4" wide....................................packed all right hand or all left hand per box of 10 End Cap-U4" wide....................................packed all right hand or all left hand per box of 10 Wall End Piece--3V4" wide............................................................................... packed per box of 10 One-Foot Filler Pieces--14" wide..................................................................packed per box of 5 Joining Pieces-2" wide..........................................................................packed per box of 20 sets Note: Finished with white prime coat of paint. 8 6 14 16 12 8 6 18 8 Replacement parts for Model HH Enclosures: Enclosure fronts-8 ft. lengths only............................................................................................ each Snap-in support bracket with slide cradle............................................................................... each For comparative and estimating purposes only. NOTE: Add 25% to accessory unit price when ordered in less than quantities indicated above. Pago 41 04570 ' ' *`1 CflQk. `Tradt :,' Prica $ 7.20 9.60 12.00 14.40 19.20 .80 2.70 3.60 4.50 5.40 7.20 .90 12.06 16.08 20.10 24.12 32.16 1.34 4.35 5.80 7.25 8.70 11.60 1.45 Trad* Pries $ 8.00 4.50 10.00 17.50 12.50 5.00 3.00 6.00 5.00 5.40 7.20 9.00 10.80 14.40 .15 2.00 .35 8.00 4.50 11.50 18.00 12.50 8.00 4.00 7.75 7.00 2.40 .35 HH-2 CONVECTORS 1 Typa K (Slock Modal) Typo F (Special Sorvica) nnunmmm Typo KC (Stock Modal) TypaS Hiiiiiiinuiinn Typo w _____ UlUUUBBfflil Type R [hiiiuiuibuhi HH-2 American-^Standard HYDRONIC HEATING MULTIFIN CONVECTORS Pries! The actual output in square feet of catalog rating-Steam (215'F.) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination. The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of units ordered. typ*** description Stock Model K KC Floor Type-free standing.............................................................. Semi-recessed-2%" flanged edges.............................................. Trade Price pnr sq ft unit extra charge $0.40 .40 $11.00 14.00 Note: For expanded prices, see pages 43 and 44. For cabinet extras, see page <6. special service F FG W FS FSG S R RG RGB RC RCG RCGB RCGB Floor Type--free standing-inlet grille.................................... Wall Hung-flat top........................................................................ Free Standing-sloping top.......................................................... Free Standing--sloping top-inlet grille.................................... Wall Hung-sloping top.................................................................. Recessed-44" flanged edges.......................................................... Recessed-H" flanged edges--inlet grille.................................. Recessed-V4" flanged edges-inlet grille with bottom overlap.............................................................................................. Semi-recessed-2V4" or 4te" flanged edges.............................. Semi-recessed-2^4" or 4V4" flanged edges inlet grille.......... Semi-recessed-2^4" flanged edges-inlet grille-with bot tom overlap.................................................................................... Semi-recessed-4%" flanged edges-inlet grille-with bot tom overlap.................................................................................... $ .41 .44 .40 .43 .46 .37 .47 .50 .50 .47 .50 .50 .50 $12.00 12.00 12.25 13.75 13.75 12.25 13.75 13.75 16.75 14.75 14.75 17.75 17.75 Not*: For cabinet extras, see page 46. Elements only (when sold less cabinets) -- steam or water 1 i u> 1 i* convector length inchot 20 24 28 32 36 40 44 48 56 64 No. 4-3%' depth approx. unit shipping no. weight 420 8 424 to 428 12 432 14 436 16 440 18 444 20 448 22 456 26 464 30 Trade Frica ( 8.40 9.10 9.80 10.40 11.15 11.85 12.40 13.10 14.50 15.90 No. 6 depth approx. unit shipping Trado no. woight Price 620 13 (10.75 624 16 11.65 628 19 632 22 636 25 12.60 13.45 14.30 640 28 644 31 648 34 15.25 16.10 16.95 656 40 664 46 18.75 20.50 No. a-7%" depth unit no. 820 824 828 832 836 840 844 848 856 864 approx. shipping weight 15 19 23 27 31 35 39 43 51 59 Trade Price (13.90 15.10 16.35 17.60 18.80 20.05 21.30 22.55 25.00 27.50 No. 10-9%" depth unit no. 1020 1024 1028 1032 1036 1040 1044 1048 1056 1064 approx. shipping weight Trade Price 21 (19.30 26 20.55 31 21.85 36 23.10 41 24.40 46 25.60 51 26.90 56 28.20 66 30.70 76 33.25 Ratings: Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined'in Commercial Standard Code CS140-47 and amendments and said ratings have been approved by the Convector Rating Committee. Standard Cabinets: Standard cabinets are furnished in prime painted sheet steel-reinforced, No. 18 gauge front and No. 20 gauge back (K and KC-No. 26 gauge), ends and top rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate con vectors listed in current literature. ONE-PIPE STEAM: Particular reference must be made on order if special service convectgrs are to be used on onepipe steam systems. Multifin convectors-for two-pipe steam or water systems-cannot be used, or modified, for one-pipe systems. Elements arranged with special one-pipe steam headers--$.06 Trade Price per square foot of cabinet output extra. Pag* 42 04571 Ame rican-^Standard H YD RON I C HEATING CONVECTORS MULTIFIN CONYECTORS TYPE rv -- STOCK MODEL -- r*EE STAriDiriG Expanded prices For use on two-pipe steam and hot water systems only. cabiaat li*f(b iaNt No. 4 depth (4 VI" cabinet) Mil 4 ft avtpal MfMihippiaf Trade Frica 20" cabinet height No. 6 depth (6Vi' cabinet) Mil a. H ft Mfpvt FF* ihaiwi|h'Mt Trad# Fria No. 8 depth (8Vi" cabinet) vail aa. *4 ft mtpvl ibIHiRWRia-f araiffel Trada Frill No. 10 depth (10Vi" cabinet) vait a. *4 ft avfpvl aRRrai. h'M'M waifhl Trada Fria 20'/, 420-20 11.3 13 $15.52 620-20 16.3 24 $17.52 24'/, 424-20 13.9 16 16.56 624-20 20.1 27 19.04 28 'h 32V4 628-20 632-20 23.8 27.6 30 34 20.52 22.04 832-20 33.6 38 $24.44 36 'h 636-20 31.3 36 23.52 836-20 38.1 42 26.24 1036-20 42.4 48 40'/, 640-20 35.1 40 25.04 840-20 42.7 45 28.08 1040-20 47.6 52 44 Vi 644-20 38.8 43 26.52 48'/, 648-20 42.6 46 28.04 848-20 51.8 52 31.72 1048-20 57.8 58 56'/, 656-20 50.1 53 31.04 856-20 60.9 60 35.36 1056-20 68.0 67 64'/a 664-20 57.6 59 34.04 864-20 70.0 65 39.00 1064-20 78.2 76 $27 96 30.04 34.12 38.20 42 28 24" cabinet height 20 Vi 24 Vi 28'/, 32'/, 36'/, 40 Vi 4*'/, 48'/, 56'/, 64 Vi 420-24 424-24 426-24 13.1 16.1 19.1 15 18 22 16.24 17.44 18.64 620-24 18.4 624-24 22.7 628-24 26.9 632-24 31.1 636-24 35.4 640-24 39.6 644-24 43 8 648-24 48.1 658-24 56.5 664-24 65.0 28 32 37 39 40 46 50 52 60 69 18.36 20.08 21.76 23.44 832-24 25.16 836-24 26.84 840-24 28.52 30.24 848-24 33.60 856-24 37.00 864-24 37.9 43.0 48.2 58.4 68.7 78.9 43 46 51 5a 66 74 26.16 28.20 1036-24 30.28 1040-24 48.6 54.4 52 56 34.36 38.48 42.56 1048-24 1056-24 1064-24 66.1 77.8 89.5 64 74 83 30.44 32.76 37.44 42.12 46.80 32" cabinet height Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 39. Special air vent assemblies. Trade Price.................. each $1 80 Damper, chain type-standard length, Trade Price, each 2 10 Metal trim strips. Trade Price Snap-On inlet grille. Trade Price. each $2 75 2 75 Page 43 04572 HH-2 CONVECTORS American-c$tadat>d HYDRONIC HEATING IHHiiiir553 | i MULTIFIN CONVECTORS TYPE KC - STOCK MODEL - PARTIALLY RECESSED Expanded prices For use on two-pipe steam and hot water systems only. No. 6 depth <6 Vi " cabinet) with 2Vi" flange cabinet length Inches approx. unit sq ft shipping Trade no. output weight Price 20" CABINET HEIGHT 20Vi 620-20 16.3 24 $20.52 24Vi 624-20 20.1 27 22.04 28Vi 62&-20 23.8 30 23.52 32'/2 632-20 27.6 34 25.04 36Vi 636-20 31.3 36 26.52 40Vi 640-20 35.1 40 28.04 44Vi 644-20 38.8 43 29.52 48Vi 648-20 42.6 46 31.04 56Vi 656-20 50.1 53 34.04 64Vi 664-20 57.6 59 37.04 No. 6 depth (6V4" cabinet) with 2Vi" flange cabinet length inches unit no. sq ft output approx. shipping weight Trade Price 24" CABINET HEIGHT 20Vi 620-24 18.4 28 $21.36 24Vi 624-24 22.7 32 23.08 28Vi 628-24 26.9 37 24.76 32Vi 632-24 31.1 39 26.44 36Vi 636-24 35.4 40 28.16 40Vi 640-24 39.6 46 29.84 44Vi 644-24 43.8 50 31.52 48Vi 648-24 48.1 52 33.24 56Vi 656-24 56.5 60 36.60 64Vi 664-24 65.0 69 40.00 Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 39. Special air vent assemblies. Trade Price................................................................................each $1.80 Damper, chain type-standard length. Trade Price . .each 2.10 Snap-On inlet grille. Trade Price............................ .......................... each 2 75 H H-2 Pig* *4 04573 AwERiCAN-c^tacdat^ HYDRONIC HEATING CONVECTORS ARCO CONVECTORS SPECIAL SERVICE LINE when sold in combination with standard cabinets COMBINATION PRICE: The actual output in square feet of catalog rating--Steam (215'F) obtained with the cabinet heights furnished deter mines the price of convectors and cabinets sold in combination. The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge muitipled by the total number of units ordered. cabinet type description Trade Price Per %q ft unit extra charge F FG W FS FSG S R RG Floor Type-free standing___ $1.29 Floor Type-free standinginlet grille.......................... 1 11 Wall Hung-flat top............ 1.29 Free Standing-sloping top ... Free Standing-sloping topinlet grille............................ Wall Hung-sloping top.......... Recessed-t4" flanged edges . . 1.35 1.38 1.29 1.28 Recessed-t4" flanged edgesinlet grille.......................... 1.31 $16.30 16 30 16.30 17.10 17.10 16.30 17.30 17.30 Standard Cabinets are furnished in: Prime painted sheet steel-reinforced. No. 18 gauge front and No. 20 gauge back, ends and top. rounded corners, streamline For illustrations of cabinets, see pape 42. For cabinet extras, see page 46. catybpin#et .descri.ption Trad# Pries par sq ft unit extra charge RGB Recessed-- H " flanged edges-- inlet grille with bottom overlap ........................ $1.31 $20.30 RC Semi-recessed-2V4" or 4V4" flanged edges ...................... RCG Semi-recessed-214" or 4V4" flanged edges-inlet grille .. 1.28 1.31 18.80 18.80 RCGB Semi-recessed-2" flanged edges-inlet grille-with bottom overlap.................... 1.31 21.80 RCGB Semi-recessed--4V4 " flanged edges-inlet grille-with bottom overlap.................... 1.31 21.80 front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convectors listed in cur rent literature. ARCO CONVECTOR -- steam or wafer ELEMENTS ONLY (when sold less cabinets) convector length Inches 18 23 28 33 38 43 48 53 58 63 No. 4 33/4" depth unit no. approx. shipping weight Trade Price 418 39 $11.82 423 50 15.26 428 61 18.69 433 72 22.14 438 83 25.58 443 94 28.91 448 105 32.33 453 107 35.78 458 128 39.23 463 139 42.66 6No. 5s/g" depth unit no. approx. shipping weight Trade Price 618 57 $17.41 623 73 22.45 628 90 27.52 633 106 32.67 638 123 37.73 643 139 42.78 648 146 47.83 653 172 52.87 658 189 57.92 663 206 63.07 No. 8 7s/a" depth unit no. approx. shipping weight Trade Price 818 71 $21.92 823 92 28.37 828 113 34.83 833 134 41.27 838 155 47.61 843 176 54.05 848 197 60.50 853 218 66.95 858 239 73.40 863 260 79.83 No. 10 9i/2" depth unit no. approx. shipping weight Trade Price 1018 84 $26.44 1023 110 34.17 1028 136 42.01 1033 162 49.74 1038 188 57.59 1043 213 65.33 1048 238 73.17 1053 264 81.01 1058 289 88.76 1063 314 96.48 Arco Convectors in lengths and depths indicated above are Standardized Sizes when sold with or without cabinets. For sizes not listed above-price on application. Page 45 04574 HH-2 CONVECTORS American-^Standard HYDRONIC HE AT INQ CABINET EXTRAS FOR MULTIFIN AND ARCO CONVECTORS HH-2 CABINET EXTRAS-STOCK MODEL MULTIFIN ONLY 1. Chain type dampers ..................................................................................................... each 2. Metal trim strips (type Konly) ...............................................................................each 3. Snap-on inlet grilles......................................................................................................each 4. Special air vent assemblies..........................................................................................each Trade Price $2.10 2.75 2.75 1.80 SPECIAL SERVICE CABINET EXTRAS-MULTIFIN AND ARCO CONVECTORS 1. Chain type dampers ..................................................................................................... each 2. Knob type dampers........................................................................................................each 3. Marking or tagging-room number or location.................................................... each 4. Access doors-lift-off type ......................................................................................... each 5. Access doors-piano hinge type ............................................................................... each 6. Stool outlet-regular sheet price, plus............................................................................ 7. Extra length-per inch or fraction thereof.................................................................... 8. Rotary cam locks............................................................................................................ each 9. Screws other than standard slotted type-per convector........................................ 10. Grille reinforcing angles-6" centers-per grille........................................................ 11. Heavier gauge cabinets-trade price per sq ft of cabinet output: 2.10 2.90 .20 2.50 2.90 1.40 .60 .70 .30 1.00 fronts only No. 18 gauge ...................................................................................... $ . .. No. 16 gauge ...................................................................................... .04 No. 14 gauge ...................................................................................... 12. Insulation--trade price per sq ft of cabinet output: .09 back only Aerocor-1" thick compressible to hk".................................... $0.12 Wood Fiberboard--thick........................................................ .12 Asbestos Millboard-y<" thick.................................................... .12 Asbestos Millboard- W thick.................................................... .18 13. Front panels only: 50% of complete convector unit price (based on No. 6 depth) 14. Cabinet only: 70% of complete convector unit price 15. Providing round pipe holes or knockouts ........................................ 16. Providing special shape cutouts............................................................ liners only $0.04 .06 .10 back, ends, and top $0.18 .24 .24 .36 price on application price on application NOTES APPLICABLE TO MULTIFIN CONVECTORS ONLY: Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 39. MINIMUM CABINET HEIGHTS WITH DAMPERS Multifin Convectors: Types FS. FSG Chain Type Dampers 18" for ff4 Depth 20" for #6 Depth 24" for if 8 4c if 10 Depths Knob Type Dampers 18" for -4 Depth 20" for -6 Depth 24" for 8 4c if 10 Depths Type S Arco Convectors: Types F. FG, W 14" for "4 & if 6 Depths 18" for Jf8 4c if 10 Depths 20" For All Depths 14" for -4 4c if 6 Depths 18" for ff8 4c - 10 Depths 20" For All Depths Types FS. FSG 24" for ~ 4,~ 6 & r8 Depths 26" for if 10 Depth 24" for -4."6 4e "8 Depths 26" for "10 Depth Type S 18" for if 4 Depth 20" for #6 Depth 26" for *84c if 10 Depths 18" for "4 Depth 20" for if 6 Depth 26" for *8 4c #10 Depths Types R. RG, RGB, RC, RCG, RCGB 24" For All Depths 20" For All Depths NOTE: Minimum heights for Arco Convectors appucaoie to x 4 (underneath) connection only Page 46 04575 American -<>t andard HYDRONIC heating TERMS TRADE PRICE BOOK Illustrations and descriptions of Plate Numbers listed in this price book will be found in the current AmericanStandard Heating-Cooling Products Catalog and literature. Items illustrated in product literature and not included in this price book are discontinued. The illustrations in this price book although actual representations of certain product in the line, do not necessarily show sires and details of all products in the line. This book contains suggested Trade Prices for certain Hydronic Heating products sold by American Radiator & Standard Sanitary Corporation ("American-Standard") through its Plumbing and Heating Division. (AmericanStandard acting through that Division is hereinafter referred to as the "Seller"). The Seller assumes no obligation to sell to anyone at any price any of the items listed herein. All prices herein set forth supersede all prior price lists and are subject to change without notice. The Seller may also, from time to time, discontinue without notice the sale of any of the products listed herein. INVOICE MINIMUM An order for items for which invoice prices aggregate less than $1.00 will be billed at $1.00. TERMS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY AMERICAN-STANDARD THROUGH ITS PLUMBING AND HEATING DIVISION All sales of goods by American-Standard through its Plumbing and Heating Division are made subject to terms and conditions printed below, in its bulletins and on its acknowledgment of order, invoice and quotation forms. These terms and conditions are as follows: PRICI Goods sold bv the Seller wilt be billed to the Buyers according to the prices and terms contained in its current bulletins and price books. In the case of orders for goods for which no price is currently in effect, the price will be determined by the Seller and set forth in the invoice issued after shipment of the goods Taxes. Any tax or other Government charge now or hereafter levied upon the ptoduction. sale, use or shipment of goods ordeied or sold, will he charged to and paid for by the Buyer DELIVERY Transportation Risks. Delivery to the initial carrier shall constitute dchvciy to the Buvci The Seller s icsponsibiiity ceases upon delivery in good Older to such cnuiei. and all goods ate shipped at the Buyer s risk. The Buvcr is uiged to examine all deliveries carefully before signing ii anspot tation receipts If goods aie visibly damaged, the Buyer should insist that written confirmation of the damage be noted on the freight bill or dray ticket by the agent of the carrier If damage is discovered after unpacking, the earner should be notified at once, so that inspection can be made and the claimed damage substantiated by the earner Interference with Deliver;. The Seller has no obligation to deliver goods against any ordet until it has accepted the order by issuance of its ac knowledgment of Older In any event, the Seller will not be liable for any dcla\ oi failure in the delivery or shipment of goods against an accepted oidci' or for an> damages suffered by reason thereof, when such delay or failure is, directly or indirectly, due to accident (in manufacture or other wise). fire, flood not, war, embargo, labor stoppages, inadequate transpoi tation facilities, shortage of material or suppltes. delay or default on the part of its vendors regulation by Government authority, or anv like oi dissimilai cause oi causes beyond its control WARRANTY Except whcic a different express written warranty has been issued with icspcCt to parliculai products no warranty express or implied, is extended by the Sellci to ans pci son or persons other than its distributors and othci dnect Du\eis To direct Buyers. the Seiler warrants only that it will fuimsh bv ficight a replacement for. or at its option repair, am pioduci of its manufactuie or part or poition thereof, proved to its satis1,k lion to he defective in material oi woikmanshtp under normal use and sei vice within one \cai aftei installation The Seller will not be respon sible foi an\ damages whatsocvei or for labor expense, in connection with the icplaccmcnt of defective pioducts or parts or portions thereof This wai rant\ is in lieu of all othei wairantics. express or implied, and of all othcr obligations or liabilities, on the part of the Seller The Sellei ncithci assumes not authoi i/es anv othei pei son to assu me for it anv othei liabilities in connection with the sale of its products except in the case of vmhcss watt antics which may be issued b> it in willing from time to time with icspcet to paiticular pioducts Goods of othei manufaciui ci s sold by the Seller are not warranted except by cxpicss wauanlics wmch may be issued in writing fiom time to time with icspcct to paiticulai products or particular sales, but tnc b.-Uei will endeavor to secuic for its direct Buyers the benefits of wai tantics extended bv the manufaciui vt s of such goods sold but not rr.anufact u i cd o> the Scl lei CONTRACT WITH BUYER Acceptance of Orders. Orders will be accepted only by the Seller s usual acknowledgment of order containing terms and conditions applicable thereto No terms and conditions appearing in a Buyer s order that are at variance with the Seller's terms and conditions shall be binding upon the Seller unless specifically agreed to by it in writing. Unless the Seller spe cifically so agrees in writing in acknowledging any order, any terms and conditions appearing In a Buyer's order contrary to those stated herein and in such acknowledgment of order are to be deemed waived by the Buyer. Receipt by the Buyer of the acknowledgment of order without prompt objection to the terms and conditions therein and herein set forth, constitutes acceptance by the Buyer of such terms and conditions Cancellation of Orders. Alter the Seller's acknowledgment of order has been issued, an order may be modified or cancelled only upon written agreement by the Seller. Orders for goods other than those of standard manufacture will not be cancelled after a commitment has been made or production scheduled. Credit for Returned Goods. Merchandise may not be returned for credit unless the Seller has agreed to accept it Where returns are accepted, a deduction of lOCi will be made for rehandling. All transportation costs for returned goods must be paid by the Buyer In any event, only salable merchandise of standard manufacture may be returned for credit Credit Approval. Buyers' orders are accepted subject to credit investiga tion and approval, and delivery may be withheld or shipment stopped in transit on accepted orders without any liability on the Seller s part. If, in its opinion, the Buyer s ability to pay for the merchandise on these terms and conditions is in doubt. SHORTAGES OR VARIANCES No claims for variances from or shortages in orders will be considered unless presented within GO days after receipt of goods PRODUCT AND PACKAGING CHANGES Factors beyond the control of the Seller and the need for continuing improvement of product require the making of changes from time to time in products and their packaging The right is reserved to make reasonable changes of any kind without notice and to deliver revised designs or mod els of goods against any order, unless on the face of the acknowledgment of order this right is specifically waived. The Seller shall have no responsibility whatever with respect to changes made by the manufacturer in products (or their packaging) sold but not manufactured by the Seller SHIPPING WEIGHTS The shipping weights given herein are approximate, for Buyers con venience only, and are not guaranteed AMERICAN RADIATOR & STANDARD SANITARY CORPORATION PLUMBING AND HEATING DIVISION Page ij 04576 HH 2 SALES OFFICES AMERic^*c$tandard HYDROPIC' HCATItiO ATLANTA 3110 Maple Drive Atlanta 5. Georgia BALTIMORE 3006 W. Cold Spring Lane Baltimore 15, Maryland BOSTON 31 St. James Avenue Boston 16, Massachusetts BUFFALO 1807 Elmwood Avenue Buffalo 7, New York CHICAGO 130 East Randolph Drive Chicago 1, Illinois CINCINNATI 1077 Celestial Street Cincinnati 2, Ohio CLEVELAND Euclid Avenue and East 14th Street Cleveland 15, Ohio DALLAS 2501 Cedar Springs Road Dallas 1, Texas DENVER 1550 East 17th Avenue Denver 18, Colorado DETROIT Suite 1440, Maccabees Building Detroit 2, Michigan HOUSTON 3400 Montrose, Suite 218 Houston 6, Texas KANSAS CITY 4709 Belleview Street Kansas City 12, Missouri LONG ISLAND 39-01 Main Street Flushing 54, Long Island, New LOS ANGELES 141 El Camino Beverly Hills, California MIAMI 46 N. E. Sixth Street Miami 18, Florida MILWAUKEE 208 E. Wisconsin Ave. Milwaukee 2, Wisconsin MINNEAPOUS 529 S. 7th Street Minneapolis 15, Minnesota NEWARK 972 Broad Street Newark 2, New Jersey NEW ORLEANS 2400 Canal Street New Orleans 19, Louisiana NEW YORK 50 West 40th Street New York 18, New York PHILADELPHIA 30 N. 5th Street Camden 2, New Jersey PITTSBURGH 714 Bessemer Bldg. Pittsburgh 22, Pennsylvania RALEIGH 611 Tucker Street Raleigh, North Carolina ST. LOUIS 2725 Clifton Avenue St. Louis 9, Missouri SALT LAKE CITY 1879 S. Main Street Salt Lake City 15, Utah SAN FRANCISCO 681 Market Street San Francisco 5, California SEATTLE 306 West Republican Street Seattle 99, Washington SILVER SPRING 8641 Colesville Road Silver Spring, Maryland EXPORT SALES Export Marketing Department American-Standard 40 West 40th Street New York 18, New York HH-2 American-Standard PLUMBING AND KEATING DIVISION AMERICAN RADIATOR & STANDARO SANITARY CORPORATION *9 WEST 40TH STREET NEW YORK 18, NEW YORK Pag* 48 04577