Document reaY5rzyJp06xKg65EZkxYD8e
14
CHAPTER 1
1965 Guide And Data Book
Thermodynamics and Refrigeration Cycles
15
Table 2 .... Specific Volume of Aqua-Ammonia Solutions* (Co ft per (b of SubcoeM or Saturated liquid)
Temp, F
Weight Concentration Amraomo in Water 0.00 0.1 . 0.2 0.3 0.4 ` 0.5 0.6 0.7 0.6 0.9 1.00
120 ,220
0.0160
0.0160 0.0161 0.0161 0.0162
0.0166 0.0167 0.0167 0.0168 0.0169 -0.0170
0.0172 0.0172
0.0173 0.0174 0.0175 0.0176
0.0177 0.0178 0.0179 0.0180 0.0182 0.0184
0.0182 0.0183 0.0185 0.0186 010189 0.0191
0.0188 0.0190 0.0192 0.0195 0.0197 0.0200
0.0196 0.0199 0.0201 0.0204 0.0208 0.0212
0.0206 0.0209 0.0213 0.0216 0.0221
0:0226
0.0218 0.0222 0.0226 0.0231 0.0236 0.0242
0.0232
0.0236 0.0242
0.0248 0.0254 0.0262
0.0247 0.0253 0.0260 0.0267 0.0275 0.0284
0.0163 0.0164 0.0165 0.0166 0.0168
.0.0171 0.0172 0.0174
0.0175 0.0177
0.0178 0.0180 0.0182 0.0184 0.0186
0.0186 0.0188 0.0191 0.0193 0.0197
0.0194 0.0197 0.0200 0.0204 0.0210
0.0204 .0.0207 0.0212 0.0216 0.0225
0.0216 0.0223 0.0226 0.0232 0.0242
0.0230 0.0237 0.0244 0.0252 0.0264
0.0249 0.0256 0.0265 0.0275 0.0288
0.0269 0.0279 0.0289 0.0304 0.0320
0.0294 0.0306 0.0320 0.0338 0.0361
Prepared by B. R. Jenningn sad F. P. Shannon.
. Temp, F
20 40,
60 80-
100 120
140 160 180 200 220
bulletin. A discussion of the methods used and new data decrease the concentration of absorbent vapor in the vapor
obtained in tins investigation is given in Reference 31.
stream going to the condenser. In order for the distillation
Data for the specific volume of aqueous ammonia solutions column to function, a stream of reflux liquid must be sup
were determined by Jennings and Shannon and are presented plied to the top of the rectifier. This reflux liquid may be a
in Table 2.
small portion of the liquid refrigerant produced in the con
Wcrter-llthium Bromide System Data
denser, but generally, a small reflux condenser is located be tween the rectifier and the main condenser in such a way that
Pressure-temperature-compotition' data for this system have been determined by Pennington"; these data have' been plotted in Fig. 20.
The enthalpy-concentration charts for the water-lithium bromide system, Figs. 21 and 22, are included here by per mission from Reference 33.
The specific gravity** of aqueous lithium bromide solutions is given-at two temperatures in Fig. 23, and the'specific heat" is plotted in Fig. 24. Viscosities" of aqueous solutions of lithium bromide solutions have been determined and are shown in Fig. 25.
the condensate from the reflux condenser drains back to the
rectifier. The amount of reflux liquid is controlled by limiting
the quantity of heat removed from the reflux condenser. The
details of the design, construction, and operation of the recti
fier, or distillation column, can.be found in any of the'stand
ard chemical anginaering textbooks on unit operations, such
as Reference 37.
. A conventional system with liquid-liquid heat exchanger
and rectifier is depicted schematically in Fig. 27.
'
Sometimes, a' refrigerant precooler is used as an additional
means' for increasing the coefficient ;of performance. This
device is simply a heat exchanger which serves to cool the
Practical Cycles
liquid refrigerant by means of the' cold vapor leaving the
evaporator. This exchanger must be located in the refrigerant
i
3.Jlithium bromide is not sufficiently soluble in water to per mit the absorber to be air cooled.
`3.'The extremely'low" pressures in the system require large Vapor conduits.
' :Fbr systems where these disadvantages are not prohibitive,
this combination can be used effcctively.
The analysis of an absorption refrigeration cycle usually consists of a series of heat balances and material balances around the various components, as well as around the cycle as a whole. For such an analysis, the information required for the working fluids consists of equilibrium pressure-tempera
It was stated earlier that the absorption cycle consisted of the four basic components: absorber, generator, condenser, and evaporator. However, it has been found necessary to add certain auxiliary components to the bade four for the pur pose of improving the coefficient of performance. This auxili ary equipment does not change the bade cycle but simply
line on the high pressure tide of the expansion device. The gain produced by this exchanger is small, however, and the saving in operating-cost does not always justify the invest ment..
A third system using dimethoxytetraethylene glycolas the ture-composition data for material -balances, and enthalpy-
improves the utilisation of the heat energy. '
J
^sorbent,' with methylene chloride as the refrigerant, was temperature-composition data for both the liquid and vapor
Fig. 17 shows that there is a continuous circulation of ab
mentioned earlier and is-typical of a whole group ofrsuch phases for heat balances. In addition to the cycle analysis,- the
sorbent from the generator to the absorber and back'to the
systems-using the ether- structure as a-hydrogen bonding designer will need data for density, viscosity, heat capacity,
generator. Since the generator operates at a much higher
rtrap.:ln addition to methylene chloride, other refrigerants and thermal conductivity for both liquid and vapor phases
temperature than does, the'absorber, the.stream of hot ab?
fetith- as the partially halogensted hydrocarbons* (Refriger- for flow calculations, heat exchanger design, pump design, etc.
sorbent leaving the generator represents a continuous loss of
22/ etc.) have been investigated as refrigerants. In *gehhM,:Systems of this type suffer from two major-disad-
Ammonia-Water System Data
heat; the sensible heat content above the temperature of tire returning stream.of absorbent being dissipated by the ab
fVdbt&gesi`namely, relatively low values of the CP and-a lack
The available data for vapor-liquid equilibria and for eo-
sorber. The desirability .of a ample liquid-liquid heat ex
of stability. Consequently,- practical machines are thalpy-temperature-composition for this system have been
changer between these two absorbent'streams is obvious., In
timitfed at this lima to the ammonia-water system and the studied and recalculated by Scatchard et al,n in an attempt
systems involving a nonvolatile absorbent, heat exchanger
water-aqueous lithium bromide system.
to combine the various fragments into a single compilation.
B generally the only auxiliary component used to improve the
Thermodynamic and Physical Data Required
Scatchard's results were then plotted on a single chart by Kohloss and Scott;*' this chart is presented here aa Fig. 19.
In 1960, the Institute of Gas Technology began a study;-
coefficient of performance of the basic cycle. Such a system is
shown in Fig. 26, and is typical of the
using water
and lithium bromide.
One of the things that has hindered the search for new -ab sorbent-refrigerant combinations is the lack of adequate data. Even for those systems which are in current use,- the available &tt6'-feil to cover ;the complete' range of conditions and the dpmgnw has to depend on extrapolations.
sponsored by the American Gas Association, to re-evaluate the ammonia-water system data and to obtain new experi mental data to fill in some of the areas of the chart not previ ously studied. At present, this work is incomplete, but the Institute is planning to publish new results in the-fonn of a
..Systems employing an absorbent having an appreciable apor pressure require a rectifier in addition to the liquidnquid heat exchanger. The ammonia-water system is the classic example. This rectifier is simply-a dt<rtiHat.mn <nliimn)
usually constructed as a part of the' generator,,which serves to