Document reZpnbz3wGnJKNxq87d11QoOG
esis. me.
3 CIGNA company
1341W. Mockingbird Lane Suite 903E Dallas. TX 75247 (214)631-4919
April 17, 1985
Mr. Terry Lohman Plant Manager J-M MANUFACTURING Denison, TX 75020
Re: ESIS 31-180
.
Dear Mr. Lohman:
On March 18 and 19, 1985, I visited- your plant to conduct an Environmental
Health Survey. As a result of this visit, I am submitting the attached recom mendation which I discussed with you. This recommendation should receive your immediate attention and consideration.
You will also find the results of the Environmental Health Report attached. This report contains the results of our survey and is an indication of the environmental health conditions that existed at that time. .
I wish to thank you and your staff for the cooperation that was extended during the course of this visit.
Will you please advise us or confirm the actions you plan to take regarding these recommendations.
Very truly yours,
Aileen Teng
u'
Certified Industrial Hygienist
AT/sh
cc: Dr. E. Edward Wang, Ph.D. J-M Manufacturing Co., Inc. A/C Pipe Corp. 1051 Sperry Rd. Stockton, CA ' 95206
Ms. Beth Ingleston
Alexander & Alexander of New York 1185 Avenue of the Americas New York City, NY 10013 `
APR. 1 9 IS 85
D 002244
KC^^IVimClNU/M IWINO
NAME:
J-M Manufacturing
LOCATION:
CIGNA
Denison. Texas
85-1 .
The asbestos exposure levels were all within the current OSHA eight hour permissible exposure limit of two fibers/cc. OSHA issued a proposed standard for asbestos in April 1984 to lower the permissible exposure limit to either 0.2 fibers/cc or 0.5 fibers/cc. It is expected that a new standard will be promulgated in the summer of 1985.
It is recommended that the OSHA proposed standard be used as a guideline to evaluate the worker's exposure. The sample results indicated that ten employees were exposed to asbestos levels over 0.2 fibers/cc. Of the ten, three were exposed to levels over 0.5 fibers/cc.
The elevated dust concentrations may be caused by inefficient dust col lecting systems, poor housekeeping and poor work practices. To assure that the dust collecting systenis are functioning properly, scheduled inspections should be conducted. If a marked reduction in performance is noted, the cause of the reduction should be identified and corrected. An industrial type vacuum cleaner equipped with a high efficiency filter system should be used to keep the workplace as free from asbestos dust accumulation as possible.
Before the exposure levels can be reduced to within OSHA proposed permissible exposure limit, NIOSH approved dust masks should be worn by the workers whose exposure levels were over the proposed limit.
C?-1A?ao Pld. in U.S.A.
D 002245
ENVIRONMENTAL HEALTH REPORT
<
PREPARED FOR: J-M Manufacturing
Denison, Texas
CONTRACT NUMBER: ESIS 51-180
PREPARED BY: Aileen Teng Certified Industrial Hygienist Loss Control Services, Inc.
ACCOMPANIED BY: Terry Lohman, Plant Manager
DATES OF SURVEY: March 18 and 19, 1985
D 002246
ENVIRONMENTAL HEALTH REPORT
< INTRODUCTION
On March 18 and 19, 1985, an industrial hygiene survey was conducted at JrM Manufacturing, Denison, Texas to evaluate the employee exposure to asbestos fibers associated with the manufacture of asbestos cement pipes. The survey was conducted at" the request of J-M Manufacturing as part of an on-going asbestos monitoring program.
The standards, guidelines, methods, results, and discussion pertinent to this report follow.
STANDARDS &`GUIDELINES
The results of this report are based on current OSHA standards and/or accepted
state of the art industrial hygiene practices to give reasonable protection to
the health and well being of your employees.
.
METHODS
Air sampling and analyses were conducted, using the following methods:
Air Contaminant
Vacuum Source
' Collection
Flow Rate
Medium
Sampling & Analyses Methods
Asbestos
'
Du-Pont P-2500 Sampling Pumps, MSA Model G Sam pling Pumps, &
Gilian Model HFS-113A Sam pling Pumps
1.4 1.6 1pm
Open face AA filters
NIOSH P & CAM 239; PCM
1pm: liters per minute PCM:- Phase Contrast Microscopy, Porton Reticle; 450 x magnification.
Samples were collected in the workers' breathing zones to obtain samples indic ative of actual employee exposure. Sampling pumps were calibrated prior to and after the sampling period.
All analyses were performed by Environmental Health Laboratory which is accred ited by the American Industrial Hygiene Association.
RESULTS Results of asbestos sampling are presented in Table I.
-1^
D 002247
J-M MANUFACTURING, DENISON, TEXAS ASBESTOS AIR SAMPLING DATA
JOB DESCRIPTION (J-M NO.)
EMPLOYEE NAME
13' Control Operator (D-2WE)
'
Jim Lang
DATE
AIR
TWA
SAMPLED
CONC.
(1)
(fibers/cc) (fibers/cc)
3/18/85
0.087
0.087
SAMPLE . TIME
(MIN.)
223
SAMPLE VOLUME (LITERS)
334.5
13' Utility Operator (D-8WE)
Paul Morrison 3/18/85
0.12
0.12
226 316.4
13' Tender (D-1WE)
Philip French 3/18/85
0.22 0.22
0.22
' 114 106
175.56 159
COMMENTS fi
13' Head Curer (D-3WE)
Arthur Dawson 3/18/85
0.15 0.14
0.14
233 238
349.5 357
13' Curer (D-3WE)
Betty Morrow
3/19/85
0.18
0.18
226
339
(1) T.W.A. - The Time Weighted Average concentration for a normal 8 hour workday. This determination is based on the assumption that the air concentration during sampling period is representative of the exposure level for the entire shift.
D 002248
J-M MANUFACTURING, DENISON, TEXAS ASBESTOS AIR SAMPLING DATA
I*
JOB DESCRIPTION (J-M NO.)
Salvage Truck Driver (D-10S)
EMPLOYEE NAME
Johnny Crain
DATE
AIR
TWA
SAMPLED
CONC.
(1)
(fibers/cc) (fibers/cc)
3/18/85
0.085
0.085
SAMPLE . TIME
(MIN.)
243
SAMPLE VOLUME (LITERS)
364.5
Willow Operator (D-7WE)
Danny Hunt
3/18/85
0.15
0.15
233 358.82
COMMENTS ll
Gen. Service Man Operating Salvage Grinder (D-8WE)
Gary Nell
3/19/85
Steam Tank Opera tor
Emmett Morrison 3/19/85
0.24 0.29
0.055
0.27
123 114
0.055
239
189.42 175.56
334.6
In-Process Inspector (D-13S)
Kevin Hannan
3/19/85
0.14
0.14
218 335.72
(1) T.W.A. - The Time Weighted Average concentration for a normal 8 hour workday. This determination is based on the assumption that the air concentration during sampling period is representative of the exposure level for the entire shift.
D 002249
J-M MANUFACTURING, DENISON, TEXAS ASBESTOS AIR SAMPLING DATA
JOB DESCRIPTION (J-M NO.)
EMPLOYEE NAME
Large Coupling Cut Off Operator (D-15F)
Bill Barnes
DATE
AIR
TWA
SAMPLED
CONC.
(1)
(fibers/cc) (fibers/cc)
3/19/85
1.3 1.5
1.4
SAMPLE . TIME
(MIN.)
223 227
SAMPLE VOLUME (LITERS)
343.42 364.98
Small Coupling Cut Off Operator (D-23F)
Larry Lewis
3/18/85
1.2
1.2
252 378
PVC Fitting As sembly Molder (D-11F)
Paul Franks
PVC Fitting Assembly - Molding Swing Saw Operator (D-12F)
Donna Simpson
3/18/85 3/19/85
0.3 1.2
0.3 190
266
1.2
206
288.4
Finishing Area Crew Leader
Bob Reynolds
3/19/85
0.081
0.081
226 .339
COMMENTS h
(1) T.W.A. - The Time Weighted Average concentration for a normal 8 hour workday. This determination is based on the assumption that the air concentration during sampling period is representative of the exposure level for the entire shift.
D 002250
J-M MANUFACTURING, DENISON, TEXAS ASBESTOS AIR SAMPLING DATA
JOB DESCRIPTION (J-M NO.)
MOA Operator (D-6F)
EMPLOYEE NAME
DATE
AIR
TWA
SAMPLED
CONC.
(1)
(fibers/cc) (fibers/cc)
Gary Templeton 3/18/85
0.28 0.56
0.4
SAMPLE . TIME
(MIN.)
131 92
SAMPLE VOLUME (LITERS)
201.74 141.68
COMMENTS (l
UPL H Unit
Loader (D-3F)
Benny Stanley 3/18/85
0.16
UPL 92 Operator (D-2F)
Billy Gordon
3/18/85
0.15
UPL 92 Helper
Glen Weger
3/19/85
UPL 92 Inspector (D-11S)
Billy Sexton
3/19/85
0.13 0.13
0.42
0.16
222
0.15
224
0.12 0.42
232 236
231
333 Handling 6" class 150 pipes
336
357.28 363.44 346.5
Handling 12" class 150 pipes
Handling 12" class 150 pipes
Handling 6" class 200 pipes on UPL 9l
Handling 12" class 200 pipes
(1) T.W.A. - The Time Weighted Average concentration for a normal 8 hour workday. This determination is based on the assumption that the air concentration during sampling period is representative of the exposure level for the entire shift.
D 002251
J-M MANUFACTURING, DENISON, TEXAS ASBESTOS AIR SAMPLING DATA
JOB DESCRIPTION (J-M NO.)
EMPLOYEE NAME
UPL //2 llydrotester Lee Crain Operator
DATE
AIR
TWA
SAMPLED
CONC.
(1)
(fibers/cc) (fibers/cc)
3/18/85
0.23
0.23
SAMPLE . TIME
(MIN.)
229
SAMPLE VOLUME (LITERS)
343.5
COMMENTS
Handling 12" class 150 pipes
UPL 112 Unit Loader (D-5F)
Ellis Pittman 3/19/85
0.19
UCL ill Operator (D-16F)
Jim Melvin
3/18/85
0.14
0.19
226
0.14
200
348.04
Handling 12" class 150 pipes
300
Large Coupling Lathe 1134 7
Larry Hallmark 3/18/85
0.10
0.10
266
404.64
Slash Saw Operator Dock Dill (D-1F)
3/19/85
0.3
0.3
208 .312
(1) T.W.A. - The Time Weighted Average concentration for a normal 8 hour workday. This determination is based on the assumption that the air concentration during sampling period is representative of the exposure level for
. the entire shift.
D 002252
J-M MANUFACTURING, DENISON, TEXAS ASBESTOS AIR SAMPLING DATA
JOB DESCRIPTION (J-M NO.)
EMPLOYEE NAME
Finishing Area Platform Driver (D-30F)
Jerry Bruce
Coupling Testing Area Inspector
James Bush
DATE
AIR
TWA
SAMPLED
CONC.
(1)
(fibers/cc) (fibers/cc)
3/19/85
0.16
0.16
SAMPLE . TIME
(MIN.)
237
SAMPLE VOLUME (LITERS)
379.2
3/19/85
0.17
0.17
218
327
COMMENTS (<
Sweeper Operator (D-6S)
Jack Bartley
3/19/85
0.18
Mechanic (D-26S)
M.E. Abernathy 3/19/85
0.12
0.18
238
0.12
224
357 336
Electrician (D-15S)
W.L. McCleskey 3/19/85
0.10
0.10
230
345
(1) T.W.A. - The Time Weighted Average concentration for a normal 8 hour workday. This determination is based on the assumption that the air concentration during sampling period is representative of the exposure level for the entire shift.
\ D 002253
ENVIRONMENTAL HEALTH REPORT
DISCUSSION
The production line for 10 foot pipes was shut down permanently in November 1984. As a result, mono saw, fitting lathe, mono lathe, radial drill, nipple lathe, perforator drill, and K & C lathe are no longer in operation.
As can be seen from the 'sample results presented in the Results section, all
the exposure levels were within current OSHA eight hour permissible exposure
limit of two fibers per cubic centimeter of air (fibers/cc). OSHA issued an
emergency temporary standard on asbestos in November 1983 which lowered the
permissible exposure limit to 0.5 fibers/cc. The emergency temporary standard
was declared invalid by court in March 1984. Subsequently, OSHA issued a
proposed standard for asbestos in April 1984 to lower the permissible exposure
limit to either 0.2 fibers/cc or 0.5 fibers/cc. It is expected that a new
standard will be promulgated in the summer of 1985 to lower exposure limit to
asbestos to 0.2 fibers/cc or 0.5 fibers/cc.
'~
It is recommended that the OSHA proposed standard be used as a guideline to " evaluate the workers* exposure. The sample results indicated that ten employees were exposed to asbestos levels over 0.2 fibers/cc. Of the ten, three (large coupling cut-off operator, small cut-off operator, and molding swing saw operator), were exposed to levels over 0.5 fibers/cc.
In finishing area, asbestos level of.each location sampled was higher than the levels found in the previous industrial hygiene surveys. The elevated dust con centrations may be caused by ineffective dust collecting systems, poor house keeping, and poor work practices.
To assure that the dust collecting systems are functioning properly, scheduled inspections should be conducted. If a marked reduction is noted, the cause of the reduction should be identified and corrected. The reduction in performance can often be traced to one or more of the following items:
A. Reduced performance by the exhaust fan caused by reduced speed due to belt slippage, reversed rotation, wear on rotor or casing, or accumu lation on rotor or casing that would obstruct air flow.
B. Reduced performance caused by defects in the exhaust piping, such as . accumulations in branch or main ducts due to insufficient conveying
velocities, condensation of oil or water vapors on duct walls, adhesive characteristics of material exhausted or leakage losses caused by loose clean-out doors, broken joints, holes worn in duct, poor connec tion to exhauster inlet, accumulations in ducts or on fan blades.
C. Losses in suction velocity can also be charged to additional exhaust points added to the system and change of setting of blast gates in branch lines.
8- -
D 002254
ENVIRONMENTAL HEALTH REPORT
DISCUSSION (Continued)
.
D. Reduced performance may be caused by increased pressure loss through
dust collector due to lack of maintenance, improper operation, wear,
etc.
.
In addition to the dust collecting systems, a wet method can be used effectively to control asbestos dust. Flooding or spraying at the point of dust generation (e.g., large coupling cut-off, small coupling cut-off, molding swing saw) is a typical method. The sprays, nozzles, and runoff controls need to be precisely designed for compatibility with the machine.
A mobile floor sweeper is used to prevent workplace from asbestos dust accumu
lation. However, the sweeper can only clean aisles and open floors. Dusts
accumulated under and between machines and on the surface of the machines and
workbenches cannot be removed. It is recommended that an industrial type vacuum
' cleaner equipped with a high efficiency filter system (9$Z efficienty for 0.3
_jum diameter aerosols) be used to keep the workplace as free from asbestos accu
mulation as possible. Appendix I contains literature on one of the asbestos
vacuum cleaners on the market.
NIOSH approved dust masks should be made available to the workers and the use of the dust masks encouraged. The workers whose exposure levels were over OSHA proposed permissible exposure limit should be required to wear the dust masks until the exposure levels are reduced to within the acceptable limit.
CONCLUSION
Implementation of the above mentioned recommendations should assist you In pro viding a more healthful working environment and reduce the potential for occu pational disease.
-9-
D 002255
*
*" V'.
'
::ih'r .;:.
INUTBMAN
* ' p - Cj:- :
". - .w
.."-V- 0-3=^--/ vVx. *
-,Y
v. .-i*:..
-
.T
_i;
MEETS OR EXCEEDS OSHA
REQUIREMENTS
FOR REMOVING AND TRAPPING DANGEROUS
ASBESTOS DUST
AND FIBERS
AND OTHER
HAZARDOUS DUST
DRY USE ONLY
Specially engineered to provide efficient and dependable protection against the serious hazard of asbestos dust and othehealth endangering airborne pollutants.
SPT OTHER s/d:
3. Final high efficiency filter certified to exceed OSHA requirements
2. impact filter.
1. Coarse filter -- disposable , paper bag
5. Paper filter protector
The well established hazards of asbestos dust have resulted in strict safety regulations by OSHA and Federal Register, Volume 39, No. 125
dated June 27, 1974 Section No. 1910. 3a (b2) states that, effective July 1. 1976, `The 8-hour time .
weighted average airborne concentrations of asbestos fibers to which an employee may be exposed shall not exceed two fibers, longer than 5 micrometers, per cubic centimeter of air, as determined by the method prescribed in Paragraph (e) of this section"
The Minuteman ASBESTOS and irritant dust vacuum has been
specially designed to aid in complying with these Federal regulations.
A certified three stage filtering system provides an efficiency rating
of 99.999% on particles of 5 micrometers in size-- exceeding
OSHA requirements.
While control of asbestos dust has come under closest government scrutiny, this specially filtered vacuum is also highly beneficial in the filtering of other toxic airborne pollutants such as: petroleum catalyst
dust, cement dust, foundry dusts, lime kiln dusts, insecticide dusts, fertilizer plant dusts and fumes, pulverized coal dust, ground limestone dust, asphalt paving dusts and others.
SPECIFICATIONS
[ Tank 715 gal.
AMPS " Static \ Air 115V .. --Lift - Volume. | Height - Cord
7 ,-:.V75* - 91 CFM -| V~32*:/: :50' 16-3
Specifications According To Manufacturer's Ratings
AMERICAN CLEANING EQUIPMENT CORPORATION 111 South Route 53. Addison. Illinois 60101 (312* 627 6900
D 002257
Minuteman
Series 800 Critical Filter Vacuums
Vacuums
. Etteetive 4/15/81 See Vacuum Tools and Attachments tor accessories.
Asbestos Vac 15
Pnc*
C-80315-01
Minuteman Asbestos Vac--H.E.P.A. Filter Vacuum
(115V. 15 Gal.. Stainless Steel Dry Only)
includes:
75021-90-- Lid Assembly (115V)
W/H.E.P.A. Filter
S4B3.00
80501-50 --Cloth Filter
$ 36.50
75022-01 --Tank Assembly Stainless Steel.
15 gal.
S368.70
38004-90 -- Bag frame
S 7.70
76059-90 -- Impact filters (10)
S 23.35
80503-80-- Filter Protectors (10)
S 16.80
76059-80-- Disposable Bags (10)
S 23.35
76104-20-- Plastic Bags (50) .
S 18.65
76053-60--H.E.P.A. (Replacement)
$194.00-
S786.00
C-80315-02
Minuteman Asbestos Vac--H.E.P.A. Filter Vacuum
(220V, 15 Gal.. Stainless Steel Dry Only)
Same as (C-80315-01) except
75021-91 lid assembly (220V)
5493.00
$796.00
C-80315-03
Minuteman Asbestos Vac --H.E.P.A. Filter Vacuum
(115V, 15 Gal.. Painted. Dry Only)
Includes:
75021-90--Lid Assembly (115V) w/H.E.P.A. Filter
- $483.00
80501-50 --Cloth Filter
S 36.50
75022-00--Tank Assembly Painted, 15 gal.
S229.00
38004-90 --Bag Frame
S 7.70
75059-90 -- Impact fitter (10)
S 23.35
80503-80-- Filter Protectors (10)
S 16.80
76059-80 --Disposable Bags (10)
S 23.35
76104-20 --Plastic Bags (50)
S 18.65
76059-60 --H.E.P.A. (Replacement)
$194.00
S696.00
C-80315-04
Minuteman Asbestos Vac -- H.E.P.A. Filter Vacuum
(220V, 15 Gal.. Painted, Dry Only)
Same as (C-80315-03) except
75021-91 lid assembly (220V)
'
$493.00.
$706.00
ASBESTOS VACUUMS Because it meets or exceeds OSHA requirements for cleaning the air of asbestos and other toxic and noxious dusts, this dry-only vacuum can be used, in offices, schools and industrial areas where daily or weekly re moval of sub-micron particles is necessary. Each Minuteman Asbestos Vacuum contains 5 different filters: disposable paper bag coarse niter (standard in 15 gal. models) for the bulk of the particles, impact niter, H.E.P.A. filter, primary cloth filter and paper filter protector. Heavy-gauge plastic drum-liner bags may be used in the 30 and 55 gallon models to safely remove large-volume pick-ups. While specifically designed for as bestos particles, this vacuum is also effective in nitering other airborne pollutants such as cement, foundry and lime kiln dusts, insecticides, fer tilizer dusts, coal dust, limestone dusts, and many others. With an effi ciency rating of 99.999% on particles of 5 micrometers, the Asbestos Vacuum is particularly useful for cleaning up after insulation operations on pipes, in removing asbestos-covered ceiling dust to prevent' snowing" and for vehicle maintenance procedures involving brakes, clutches and other asbestos-loaded material. Each unit features a 2 stage by-pass motor, front casters, 8" rear wheels and a carriage handle. An optional starter tool kit is recommended for each unit.
HEflfe
H.E.P.A. Filter impact Filter Cloth Filter Filter Protector Disposable Bag Intake
Exhaust
D 002258
ies 800 Critical Filter Vacuums
Gnn' Gtscnpttor
>30-01
Minuteman Asbestos Vac--H.E.P.A. Filter Vacuum
(115V. 30 Gal.. Painted, Dry Only)
Includes:
75021-90- Lid Assembly (115V)
w/H.E.P.A. Filter
$403.00
80504-70 --Cloth Filter
$46.30
80601-70--Adapter Ring (30 gal.)
. $102.00
90007-80--Tank Assembly Painted. 30 gal.
SI26.00
90004-80-- Dolly Cart
S137.00
76059-90--Impact filter (10)
S 23.35
80503-80--Filter Protectors (10)
S 16.80
80503-70-Plastic Drum liners (12)
$ 23.25
76059-60 -- H.E.P.A. filter (Replacement)
$194.00
S957.00
30-02
Minuteman Asbestos Vac--H.E.P.A. Fitter Vacuum
(220V. 30 Gal., Painted, Dry Only)
Same as (C-80330-01) except
75021-91 lid assembly (220V)
$493.00
S967.00
55-01 '
Minuteman Asbestos Vac -- H.E.P.A. Filter Vacuum
(115V. 55 Gal.. Painted, Dry Only)
Includes:
75021-90--Lid Assembly (115V)
w/H.E.P.A. filter 80504-70-Cloth Rlter 80601-80--Adapter Ring (55 gal.)
$483.00 $46.30 S102.00
90001-50--Tank Assembly Painted. 55 gal.
S 92.00
90004-80--Dolly Cart 76059-90 -- Impact filters (10) 80503-80--Filter Protectors (10)
S137.00 S 23.35 $ 16.80
80504-60--Plastic Drum liners (12)
S 25.70
76059-50 -- H.E.P.A. (Replacement)
SI 94.00
S926.00
55-02
Minuteman Asbestos Vac -- H.E.P.A. Filter Vacuum
(220V. 55 Gal.. Painted. Dry Only)
Same as (C-80355-01) except
75021-91 lid assembly (220V)
$493.00
$936.00
>9-00
i7a Tool Kit For Asbestos Vac
(1 'j'. Dry only)
Includes:
a. 80101-00--10' x 11V Hose
b. 80001-50--11V Wand (Operator's handle)
c. 80007-00--Gulper Tool
d. 80002-40--3" Round Brush
e. 80011-60--1Vi"x 8* Swivel Connector
f. 76059-80--10 Disposable Paper Bags
g. 76059-90--12 Impaction Pre-Filters
h. 76104-20--50 Plastic Bags
i. 80503-80--12 Filter Protectors
No substitution of tools.
$218.00
$40.40 $ 28.75 $ 38.00 $ 14.75 $ 14.75 $ 23.35 $ 23.35 $ 18.65 $ 16.80
Asbestos Vac 30/55
002259