Document reXakL776y4vpLQwOqygqqXgE
W. B. PAPAOEORGB - ST. LOUIS JULY 17* 1970
H. S. BERGEN
D, S. CAMERON - BRUSSELS W. S. CLARK E. M. EMEHY - JPQ
M. W. FARRAR - 2ND STREET R. E. KELLER - 2ND STREET R. M. KOUNTZ
J. MASON
R. He MUNCH - 2ND STREET P. A. OLSON e Re RICHARD
J. Re SAVAOS J. E. SPRINOOATE
Ke Se TUCKBt - 2ND STREET He Ae YODDBf - RUABON
E. P. WHEELER
I reviewed our biodegradation studies with R. Hunch* R. Kountz* S* Tucker, E. Bnery and J, Savage on Thursday* July 16, 1970
1. Monsanto-USA Studies
River die-away studies Indicated Aroclor 1221 disappears* Aroclora 1242* 1248 and 1254 were
undegraded
Seml-continuous activated sludge studies Indicate
that selective degradation of specific homologs does occur.because peaks normally present In Aroclor 1221* 1242 and 1248 disappear.
2. Monaanto-U.K. Studies
Shake flask studies demonstrate that 2,4*-,
, *, , -*2,2,3- and 2,34`- Isomers degrade readily.
2 2 4 6 2,2*,4,4*, and 4,4* do not degrade.
Ruabon laboratory also demonstrated by peak analysis that MCS-1016 and Aroclor 1130 are
more degradable than Aroclor 1242.
3. Bivlronment Samples
,'
Investigators In both Europe and USA find Isomers In wildlife that resemble those In Aroclor 1254.
Predominant homologs present In Aroclor 1242 are usually not found except close to Industrial plants. Since ''large quantities of Aroclor 1242 are produced and released to the environment*
degradation must be occurring.
TRAN 036322
HARTOLDMONOQ27118
"S'*
Evidence of degradation has been noted by
Monsanto laboratory in studies of foundry
plant settling ponds* milk and fish. Peaks
which are present in the original Aroolor
are modified or missing in the sample extract
indicating degradation.
...
4. MCS-1016
,
Considerable discussion was held on what is
meant by "biodegradable" when describing MCS-1016. Capacitor customers Z visited had
the erroneous impression that this meant the material could be introduced into the plant sewer system and would be non-detectable a
very short distance downstream. For our purposes* the term "biodegradable" means that
peaks which persisted through the biodegradation tests with Aroolor 1242 are significantly reduced in this distilled product. Neither Aroolor 1242 or MCS-1016 can be dumped into the environment. Users of either material must exercise control. In some instances this may require activated sludge treatment units. It
is generally agreed that the relative Improvement in biodegradability is an advantage which the capacitor Industry will find Interesting. We must establish if the less controllable hydraulic fluids applications can materially benefit from
the use of MCS-1016.
5. Current Work
At Ruabon* work continues on HB-40, Aroclors and Pyralene 1500 (a competitive product) Dr. W. C. Evans* University of North Wales* Bangor
is investigating some microorganisms which he believes are effective on PCB's.
Z. Snery is completing his studies on HB-40 and
MIPS. He will immediately start tests to , determine relative per cent degradation of Aroolob 1242* Aroolor 1254, MCS-1016 and Aroolor
1230B. These tests take about 3 weeks to complete and his equipment provides for testing four products at a time. Analytical facilities are manned 7 days per week* 12 hours per day. Equipment needs are being evaluated.
TRAN 036323
HARTOLDMON0027119
-3-
The backlog of products to be tested continues to increase. The Applied Sciences Group continually reviews the list to re-establish continuing changes in priorities. In summary, emphasis on this work has been accelerated within the past three months, the work is progressing as planned and our facilities are being utilized to the praetioal limit.
W. B.PAPAGBORQE ms
TRAN 036324
HARTOLDMON0027120