ArocLor 1242 El II is well known that the working life of a.c, paper The concentration of the additive will be slightly capacitors impregnated with askarels can be extended reduced by a batch treatment process with Fullers' by the addition to the askarel of small amounts of earth or other adsorbent. In order to allow for this suitable epoxy compounds, known as `scavengers'. reduction, the initial concentration of the additive This effect is especially beneficial in the case of has been set at a slightly higher level than would capacitors operating under arduous service condi otherwise be necessary. In this way, after a batch tions, such as those subjected to frequent surges. treatment with an adsorbent of normal activity at a concentration up to about 1% by weight, the final However, some epoxy compounds have been found concentration of the additive will be sufficient to give to be very difficult to control under the practical protection to the capacitors. conditions obtained in existing capacitor impregna tion plants. If the impregnant is purified by percolation through a refining column the additive will be initially heavily Aroclor 1242 El consists of electrical quality Aroclor 1242 to which a specially purified epoxy compound has been added at just above the concentration af which it will be used. This product has been developed to provide convenient processing in the capacitor impregnation plant as well as sufficient activity to give an effective scavenging action in the depleted by the adsorbent. However, the adsorbent later becomes `saturated' with the additive whilst continuing to remove ionic impurities from the impregnanf. The volume of impregnant required to saturate the adsorbent depends upon its mass and activity. finished capacitor. The properties of Aroclor 1242 El (see Table 1) are The vapour pressure of the additive itself is very much lower than that of Aroclor 1242 so that the concentration of the additive will not be reduced the same as those of Aroclor 1242 except for the following: Scavenger Content: equivalent to 1.9 to 2.1 mg HCI/g during the degassing stage of the process when this is Dissipation Factor (tan 6) at 100C, 50 Hz: <3% carried out over the usual ranges of temperature and Resistivity at 100 C, 500V, 1 min.: > 1 T n cm. pressure. Monsanto TOWOLDMON0034408 WATER_PCB-00018877 Table 1 Aroclor 1242 El. Tentative Data PROPERTY TEST METHOD UNITS Appearance ASTM D 1702 - Colour ASTM D 1702 Density et 20 C ASTM D 1810 & 1SO/R 649 Refractive Index at 20 CC ASTM D 1B07 Kinematic Viscosity et 20C ASTM D 446 Flash Point ASTM D 92 Fire Point ASTM D 92 Pour Point ASTM D 97 APHA fl/cm' -- cSt C C C VALUE clear liquid free from suspended matter and sediment. 50 max. 1,38 to 1,39 1.6250 to 1.6270 65 to 71 153 min. none to boiling point. -18 max. Neutralization No. Inorganic Chlorides Water Content Hydrolyzable Chlorides Scavenger Content Monsanto ASTM D 1821 ISO/R 760 ASTM D 2441 Monsanto (Appendix 1) mg KOH/g ppm ppm ppm mg HCL/g 0.01 max. 0.05 max. 30 max. 1.0 max. 1.9 to 2.1 Volume Resistivity at 100C, 600V, 1 min. Monsanto Dissipation Factor (tan 6) at 100T, 50 Hz Monsanto Relative Permittivity at 100C, 50 Hz Monsanto T o cm % _ > 1 min. < 3 max. 4.7 to 4.9 A suitable method for estimating the scavenger content is given in Appendix 1, It has sometimes been found difficult to clean the dielectric test celts that are used to measure the dissipation factor and resistivity of epoxide-containing askarels. We have found that it is helpful first to standardize the cell with pure Aroclor 1242 whose dis sipation factor is already known. If this measurement is satisfactory, the cell is then rinsed twice with Aroclor 1242 El and the measurement proceeds in the usual way. This product should be treated from the toxicity and safety aspects in the same way as Aroclor 1242 (see Appendix 2). For further information contact Monsanto at 10-18 Victoria Street, London SW1H ONQ, Telephone 222 5678 or at Place Madou 1, 1030 Brussels, Telephone 19.11.01. 2 TOWOLDMON0034409 WATER_PCB-00018878 Appendix 1 Test Method for determining the quantity of hydrogen chloride scavenging additive in Aroclor 1. Principle The method involves titrating the oxirane oxygen in glacial acetic acid with a standard perchloric acid solu tion to a crystal violet end-point, The titration is carried out in an excess of quaternary ammonium bromide, which, on contact with perchloric acid, produces hydro gen bromide. The hydrogen bromide, in turn, reacts with the oxirane oxygen. 2. Roagents (a) Glacial acetic acid (b) Chloroform (c) Perchloric acid solution -0.1 N in glacial acetic acid (standardize against potassium hydrogen phthalate). (d) Crystal violet--1% solution in glacial acetic acid. (e) Tetraethyl ammonium bromide solution -dissolve 100 g in 400 cm48 o5f*g*lacial acetic acid. 3. Apparatus (a) 10 cm* burette (b) Usual laboratory glassware 6. Additional Notes (a) The titrant is very stable and does not require frequent ^standardization. (b) No blank correction should be required if good quality reagents are used. Appendix 2 Toxicity and Safe Handling 1. Avoid skin contact. Protect the hands, preferably by oil-resistant gloves. 2. If skin contact should occur, wash off with soap and water. 3. If hot Aroclor must be handled in a closed or confined area provide exhaust ventilation or wear an approved respirator. 4. If Aroclor gets in the eyes, flush with large amounts of water. In the event that irritation persists refer the patient to a Physician. 5. Exposure to vapours or mists should be avoided. If these precautions are neglected acne may develop and excessive exposure may cause liver damage. 4. Procedure (a) Weigh 2.5 to 3.0 of the askarel to the nearest 0.05 g into a 125 cm8 Erlenmeyer flask. (b) Add 10 cm8 of chloroform, 40 cm* of glacial acetic acid and 10 cm8 of the tetraethyl ammonium bromide solution and swirl to dissolve. (c) Add 1 drop of crystal violet indicator and titrate with 0,1 N perchloric acid to the greatest colour range (violet to grccn-blue). 5. Calculation Hydrogen chloride equivalence (mg/g) = 36.5 xTxN W W'hcre T-litre of perchloric acid (cm8) N- normality of perchloric acid W - weight of sample (g) Caution Aroclor is composed of polychlorinated biphenyls, which some studies have shown may be an environmental contaminant. Extreme care should be taken to prevent any entry into the environment through spills, leakage, use, disposal, vaporization or otherwise. The information in this bulletin is to our best knowledge true and accurate but ell instructions, recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control. Monsanto Company and its subsidiaries disclaim Bny liability for loss or damage suffered from use of these data or suggestions. Furthermore no liability is accepted if use of any product in accordance with these date or suggestions infringes any patent. Published by Monsanto Europo S.A. 11 -27(E)M-E-I- (1/72) Aroclor is a Registered Trade Mark 3 TOWOLDMON0034410 WATER_PCB-00018879