Document reR0m9MXYayGdQE2BXxEEyML7
SGT
SGS INSTITUT FRESENIUS GmbH Postfach 1261 65220 Taunusstein
INSTITUT FRESENIUS
FluorTex GmbH Herrn Detlef Reichl Auf der Groeb 2c DE-83064 Raubling
Taunusstein, 07/04/2017
Zamien Sarkardeh / jn
Project Manager Hardlines
Tel.:
, Fax:
gsgs.com
Consumer and Retail
Non Food
Pri.ifbericht Nr. / Test-report no. 3310995-02
Priifbericht-Version / Test-report version < 2 >
Dieser Bericht ersetzt Prufbericht 3310995-02 Version <1> vom 30/03/2017 / This test report replaces test report 3310995-02 version <1> of 30/03/2017
Original Probe Nr. / Original Sample ID
170239984
Probenbeschreibung / Sample Description
multiFlon ePTFE Dichtungsplatte / gasket sheet 3 mm
Probeneingang / Sample Receipt Date 06/03/2017
Allgemeine Angaben / General Information
0' SGS-Kundennr. / SGS-Client's ID
0' SGS-Kundenauftrag / SGS-Customer-Order
0
Auftragserteilung / Ordering date
10156588 : 4085499 : 03/03/2017
Prufzeitraum / Testing period
: 09/03/2017 - 20/03/2017
Bestell-Nr. / Order No.
Artikel-Nr. / Item No.
151151530
Prufumfang / Testing scope
Prilfung nach Prufvorschlag Test according to test suggestion
Beurteilung / Assessment
Priifanforderungen / Overall assessment
bestanden / pass
Die Probe entspricht in den Untersuchungspunkten den Anforderungen des 21 CFR 177.1550.
The sample meets the requirements of FDA 21 177.1550 in the tested items.
SGS INSTITUT FRESENIUS GmbH
(Project Manager)
I.A. Claas, emer (Project Manager)
R:\F\FluorTex GmbH 10156588\2017\4085499 PTFE Dichtungsplatte\PB 331099502 rev01 4085499 FDA.doc
Seite /page 1 / 5
SGS INSTITUT FRESENIUS GmbH I Im Maisel 14 D-65232 Taunusstein t +49 6128 744 - 0 f +49 6128 744 -130 www.institut-fresenius.sgsgroup.de
Member of the SGS Group (Societe Generale de Surveillance)
Die Prillergebnisse beziehen sich auf die untersuchten Proben. Die Veroffentlichung und Vervielfaltigung unserer Prilfberichte und Gutachten zu Werbezwecken sowie deren auszugsweise Verwendung in sonstigen Fallen bediirfen unserer schriftlichen Genehmigung. Me Dienstleistungen werden auf Grundlage der anwendbaren Allgemeinen Geschaftsbedingungen der SGS, die auf Anfrage zur VerfOgung
gestellt werden, erbracht.
Geschaftsfuhrer: Stefan Steinhardt Aufsichtsratvorsitzender: Dirk Hellemans, Sitz der Gesellschaft Taunusstein, HRB 21543 Amtsgericht Wiesbaden
FluorTex GmbH Auf der Groeb 2c
DE-83064 Raubling
Prfbericht Nr. / Test report no. 3310995-02 Prfbericht-Version / Test-report version < 2 >
SGS Auftragsnr./ SGS Order No.: 4085499 Datum / Date: 07/04/2017
Seite / Page 2/5
Zusammenfassung der Analysenergebnisse / Summary of results
Prfung / Test FDA 21 CFR 177.1550 extrahierbare Anteile / FDA 21 CFR 177.1550 extractable fraction FDA 21 CFR 177.1550 extrahierbares Fluor / FDA 21 CFR 177.1550 determination of fluorine
Ergebnis / Result bestanden /pass
bestanden / pass
Bemerkung: Note:
Die Beurteilung erfolgt auf Basis der Prfergebnisse der entnommenen Teilproben des vorliegenden Prfmusters.
Die Beurteilung der Ergebnisse erfolgt anhand der genannten Anforderungen, ohne Bercksichtigung etwaiger Messunsicherheiten. Fr die Bildung von Summen werden nur Messwerte oberhalb der jeweiligen Bestimmungsgrenze bercksichtigt.
Prfungen von Mischproben von reprsentativen Teilproben wurden auf Kundenwunsch durchgefhrt. Das Ergebnis bezieht sich auf die Mischprobe und nicht auf die Teilprobe.
Die Prfung von Mischproben erfolgt auf Kundenwunsch und kann eine Abweichung von der genannten Prfnorm darstellen.
Fr Mischproben mit zwei Bestandteilen, die die Hlfte der genannten Anforderungen berschreiten, oder Mischproben mit drei Bestandteilen, die ein Drittel der genannten Anforderung berschreiten, besteht die Mglichkeit, dass ein oder mehrere Bestandteile die Anforderungen nicht bestehen. In diesen Fllen empfehlen wir eine separate Prfung der Bestandteile.
Conclusions on pass/fail are based on the test result from the actual sampling of the received sample(s).
Conclusions are based on the relevant requirements; measurement uncertainties are not taken into account. Only results above the relevant detection limit are taken into account for the calculation of sums. Test was conducted on composite of random parts of the item as per client's request and the test result is the overall result. The composite sampling method is based on the client's special request and could be a modification from the testing standard.
For 2-composite mix with results exceeding one half of the relevant requirements or 3-composite mix with results exceeding one third of the relevant requirements, the composite sample may have the possibility of one or more components that can lead to a failure result, it is recommended to test on individual basis.
SGS Institut Fresenius GmbH, Im Maisel 14, D-65232 Taunusstein The analytical findings are only valid for the sample as analyzed. Written acknowledgement for publication and duplication of our analytical reports for promotional purpose, as well as fractional use for other purposes mandatory. Electronically submitted results are for your information only. For legally binding results refer to the originally signed analytical report. Numbers following ,,<" represent limits of quantification. Determination of parameters marked with * was performed with a cooperation partner. Please note that the analysis was fully or partially conducted at the laboratory facilities of Institut Fresenius which are accredited according to DIN EN ISO/IEC 17025. These laboratory facilities are not explicitly accounted as GMP-areas.
FluorTex GmbH Auf der Groeb 2c
DE-83064 Raubling
Prfbericht Nr. / Test report no. 3310995-02 Prfbericht-Version / Test-report version < 2 >
SGS Auftragsnr./ SGS Order No.: 4085499 Datum / Date: 07/04/2017
Seite / Page 3/5
Photodokumentation / Photo documentation
Teilproben-Liste / List of sample parts
Teilpr. Nr / Comp. no
1
Teilproben ID / Component-ID
170245099170245702
Proben-Beschreibung / Sample-Description
PTFE
Dichtungsplatte / gasket sheet
Originalproben-ID / Original Sample ID
170239984
SGS Institut Fresenius GmbH, Im Maisel 14, D-65232 Taunusstein The analytical findings are only valid for the sample as analyzed. Written acknowledgement for publication and duplication of our analytical reports for promotional purpose, as well as fractional use for other purposes mandatory. Electronically submitted results are for your information only. For legally binding results refer to the originally signed analytical report. Numbers following ,,<" represent limits of quantification. Determination of parameters marked with * was performed with a cooperation partner. Please note that the analysis was fully or partially conducted at the laboratory facilities of Institut Fresenius which are accredited according to DIN EN ISO/IEC 17025. These laboratory facilities are not explicitly accounted as GMP-areas.
FluorTex GmbH Auf der Groeb 2c
DE-83064 Raubling
Prfbericht Nr. / Test report no. 3310995-02 Prfbericht-Version / Test-report version < 2 >
SGS Auftragsnr./ SGS Order No.: 4085499 Datum / Date: 07/04/2017
Seite / Page 4/5
Untersuchungsergebnisse / Analytical results
FDA 21 CFR 177.1550 - extrahierbare Anteile / extractable fraction
Prfmethode / Test Method 21 CFR 177.1550 Die extrahierbaren Anteile werden gravimetrisch bestimmt / the extractives have been determined gravimetrically
Simulanz / simulant Dauer / duration
Wasser / water 2 Stunden Rckfluss / 2 hours reflux
Teilprobe(n) / Subsample(s)
extrahierbare Anteile / extractable fraction Beurteilung / Conclusion
Einheit / Unit
Ergebnis / Result 1
mg/in
< 0.05 bestanden / pass
Simulanz / simulant Dauer / duration
50% Ethanol / 50% ethanol 2 Stunden Rckfluss / 2 hours reflux
Teilprobe(n) / Subsample(s)
extrahierbare Anteile / extractable fraction Beurteilung / Conclusion
Einheit / Unit
Ergebnis / Result 1
mg/in
0.06 bestanden / pass
Simulanz / simulant Dauer / duration
n-Heptan / n-heptane 2 Stunden Rckfluss / 2 hours reflux
Teilprobe(n) / Subsample(s)
extrahierbare Anteile / extractable fraction Beurteilung / Conclusion
Einheit / Unit
Ergebnis / Result 1
mg/in
0.06 bestanden / pass
Simulanz / simulant Dauer / duration
Ethylacetat / ethyl acetate 2 Stunden Rckfluss / 2 hours reflux
Teilprobe(n) / Subsample(s)
extrahierbare Anteile / extractable fraction Beurteilung / Conclusion
Einheit / Unit
Ergebnis / Result 1
mg/in
0.05 bestanden / pass
Anforderung: Requirement:
max. 0,2 mg/in (21 CFR 177.1550) max 0.2 mg/in (21 CFR 177.1550)
SGS Institut Fresenius GmbH, Im Maisel 14, D-65232 Taunusstein The analytical findings are only valid for the sample as analyzed. Written acknowledgement for publication and duplication of our analytical reports for promotional purpose, as well as fractional use for other purposes mandatory. Electronically submitted results are for your information only. For legally binding results refer to the originally signed analytical report. Numbers following ,,<" represent limits of quantification. Determination of parameters marked with * was performed with a cooperation partner. Please note that the analysis was fully or partially conducted at the laboratory facilities of Institut Fresenius which are accredited according to DIN EN ISO/IEC 17025. These laboratory facilities are not explicitly accounted as GMP-areas.
FluorTex GmbH Auf der Groeb 2c
DE-83064 Raubling
Prfbericht Nr. / Test report no. 3310995-02 Prfbericht-Version / Test-report version < 2 >
SGS Auftragsnr./ SGS Order No.: 4085499 Datum / Date: 07/04/2017
Seite / Page 5/5
FDA 21 CFR 177.1550 - extrahierbares Fluor / determination of fluorine
Prfmethode / Test Method 21 CFR 177.1550 Die extrahierbaren Anteile werden gravimetrisch bestimmt / the extractives have been determined gravimetrically
Simulanz / simulant Dauer / duration
Wasser / water 2 Stunden Rckfluss / 2 hours reflux
Teilprobe(n) / Subsample(s)
extrahierbare Anteile / extractable fraction Beurteilung / Conclusion
Einheit / Unit
Ergebnis / Result 1
mg/in
< 0.01 bestanden / pass
Simulanz / simulant Dauer / duration
50% Ethanol / 50% ethanol 2 Stunden Rckfluss / 2 hours reflux
Teilprobe(n) / Subsample(s)
extrahierbare Anteile / extractable fraction Beurteilung / Conclusion
Einheit / Unit
Ergebnis / Result 1
mg/in
< 0.01 bestanden / pass
Simulanz / simulant Dauer / duration
n-Heptan / n-heptane 2 Stunden Rckfluss / 2 hours reflux
Teilprobe(n) / Subsample(s)
extrahierbare Anteile / extractable fraction Beurteilung / Conclusion
Einheit / Unit
Ergebnis / Result 1
mg/in
< 0.01 bestanden / pass
Simulanz / simulant Dauer / duration
Ethylacetat / ethyl acetate 2 Stunden Rckfluss / 2 hours reflux
Teilprobe(n) / Subsample(s)
extrahierbare Anteile / extractable fraction Beurteilung / Conclusion
Einheit / Unit
Ergebnis / Result 1
mg/in
< 0.01 bestanden / pass
Anforderung: Requirement:
max. 0,03 mg/in (21 CFR 177.1550) max. 0.03 mg/in (21 CFR 177.1550)
*** Ende des Berichts *** / *** End of test report ***
SGS Institut Fresenius GmbH, Im Maisel 14, D-65232 Taunusstein The analytical findings are only valid for the sample as analyzed. Written acknowledgement for publication and duplication of our analytical reports for promotional purpose, as well as fractional use for other purposes mandatory. Electronically submitted results are for your information only. For legally binding results refer to the originally signed analytical report. Numbers following ,,<" represent limits of quantification. Determination of parameters marked with * was performed with a cooperation partner. Please note that the analysis was fully or partially conducted at the laboratory facilities of Institut Fresenius which are accredited according to DIN EN ISO/IEC 17025. These laboratory facilities are not explicitly accounted as GMP-areas.