iuetci. Interim Report
PLAINTIFF'S EXHIBIT
Bel Laboratories
r September 7, 1976 trom' G. D. Kenney
Introduction In the early part of 1975 A.T.&T. formed a committee
called the Bell System Occupational Health Working Group (OHWG). The purpose of this committee was to Investigate the exposures of employees in TELCO's to various environmental insults.
, This committee which consists of representative^
from A.T.ST., Western Electric, Bell Labs and two operating TELCO's contracted with the Bell Lab3 Environmental Health A Safety Department to perform a Baseline Industrial Hygiene Study. The purpose of this study was to obtain measurements on the exposures of Bell System employees to determine baseline con ditions including exposures to toxic or harmful agents.
31nce the summer of 1975 measurements have been taken in - different operating TELCO's. These measurements In clude: asbestos
in
addition certain practices and procedures were reviewed to de
termine if they are being followed.
The following report summarizes the findings of these
measurements and makes some recommendations based on the findings.
RESULTS AND RECOMMENDATIONS
j
Asbestos Asbestos measurements were taken in central offices,
business offices, and on the operation of changing and/or in specting brakes.
The following table presents a brief summary of these results.
2
Asbestos
Bulldlng/Area
Concentration f/cc
CO/Equip. Frames
0.01 - 0.3
CO/Mec. equip, room
0.01 - 0.09
DO/Offlees Garages/Changing Brakes
0.01 - 0.2 0.04 - 0.3
Outside/Arabient
0.01 - 0.4
The present OSHA standard for asbestos is 2 fibers
per cubic centimeter greater than 5 micrometers in length (2f/oc).
Before discussing the results further a brief dis
course on the method of analysis for asbestos fibers might be
appropriate. The present method of analysis call3 for th^
fibers to* be counted using a phase contrast microscope. The
standard calls for any particle having an aspect ratio (the
length of the fiber over the width of the fiber) of the 3 to 1
or greater and a length greater than five micrometers it is to
be counted. This method does not positively Identify the fiber i
as an asbestos fiber. If the analyst feels that the fiber is
not of the asbestosform type the wording of the present standard
requires it to be counted as an asbestos fiber.
From the table it can be seen that the asbestos levels
measured are well below the present OSHA standard of 2 fibers/cc.
Kost of the exposure levels are of the same magnitude as the
ambient levels.
The only exposure listed In this table that have
been reported elsewhere in the scientific literature is on
changing brakes. One report gives values much higher than the
OSHA standard, another report gives values close to those ae-
ported here. Further mear rements on these exposures are Being
planned.
In general the exposures of Bell employees to asbestos
is the same as they would experience from an ambient exposure.
Although the exposures are low the provisions for medical ex
aminations in the present standard may present problems. As
the standard now reads any exposure to asbestos fibers triggers
the requirement of medical exams (note the key word "any").
LLA 000759
. REDACTED DRAFT
Strictly interpreted this could mean all Bell System
employees should undergo medical exams. The A.T.iT.
OHWQ has taken steps to clarify this matter with
OSHA.
In addition, to air samples for asbestos fibers
analysis of certain insulating materials used on boilers,
steam pipes and ventilation ducts. The results of these analyses showed that some materials contained as much as
55% asbestos. Potential high exposures do exist for certain
Bell employees. These employees include, brake mechanics,
maintenance men working on insulating materials, and plant
personnel, pulling cable through transite duct.
^
A program should be developed to identify, monitor exposures and perform physicals on employees who may be
exposed to asoestos. In addition examine various supplies
to determine if they contain asbestos. If possible these
supplies should be discarded using proper procedures. If
they cannot be discarded they must be packaged and labelled
in the proper manner.