Document reOXo0yJbLpaRK1vY7j0x9jnv
346
CHAPTER 18
1948 Guide
are considered consistent with good practice, although there are boilers which have high efficiencies and also operate at higher transmission rates.
TESTING AND RATING CODES
The Society has adopted four solid fuel testing codes, a solid fuel
rating code, and an oil fuel testing code.
.
ASHVE Standard and Short Form Heat Balance Codes for Testing Low-Pressure Steam Heating Solid Fuel Boilers--Codes 1 and 2-- (Revision of June, 1929) l, are intended to provide a method for con
ducting and reporting tests to determine heat efficiency and performance characteristics.
ASHVE Performance Test Code for Steam Heating Solid Fuel Boilers --Code No. 3--(Edition of 1929)1 is intended for use with ASHVE
Code for Rating Steam Heating Solid Fuel Hand-Fired Boilers2. The
object of this test code is to specify the tests to be conducted and to provide a method for conducting and reporting tests to determine the efficiencies and performance of the boiler.
The ASHVE Standard Code for Testing Steam Heating Boilers Burn ing Oil Fuel5, (Adopted June, 1932), is intended to provide a standard method for conducting and reporting tests to determine the heating efficiency and performance characteristics when oil fuel is used with steam heating boilers.
In 1938 the Society adopted a Standard Code for Testing Stoker-Fired Steam Heating Boilers4, (Adopted June, 1938), which is intended to provide a test method for determining the efficiency'and performance characteristics of any stoker and boiler combination burning any type of solid fuel such as anthracite or bituminous coal:
. The Steel Boiler Institute, Inc. has adopted (June 12, 1945) a Rating Code for Commercial Steel Boilers and Residential Steel Boilers and for Testing Oil-Fired Residential Steel Boilers. The commercial boilers (defined as those having 129 to 2500 sq ft of heating surface) are rated in
Table 1. SB/. Net Rating Data for Residential Steel Boilers--Oil Fireds
Sq Ft Steam
275 320 400 550
700 900 1100
1300 1500 1800
2200 2600 3000
SBI Net Rating
Sq Ft Water
440 510 . 640 ' 880
1120 1440 1760
2080 2400 2880
3520 4160 4800
h;
Btu
66000 ;77000 96O0O 132000
168000 216000 264000
312000 360000 432000
528000 624000 720000
. Minimum _ . Furnace
Volume Cu Ft
Heating Surface Sq Ft ,'
2.5 "
2.9 3.6 5.0
6.4 . 8.2
10.0
'
11.8' 13.6 16.4
.
20.0 23.6 27.3
16 19 24 32
41 . . 53 '65
77 ' 88 . 106
129 153 177
"Stoker-fired and Gas-fired SBl Net Rating not greater than Oil-fired. Hand-fired, SBI Net Rating (Steam) not greater than 14 times the square feet of heating surface. '
Heating Boilers and Furnaces
T a b le 2. S B I Ratings for Commercial Steel Boilers
ftBltuminous'Stoker Fired.
347