Document reMVakw1Mmwy8zXNXMk2RXjQJ
FRICTION MATERIALS STANDARDS INSTITUTE, INC., EAST 210 ROUTE 4, PARAMUS, NJ 07652
BULLETIN NO. 860
July 9, 1986
NIOSH METHOD 7400 FOR MEASURING ASBESTOS DUST CONCENTRATIONS
Thu National Institute for Occupational Safety and Health (NIOSH) has adopted their Method 7400 for making airborne asbestos fiber counts. They note 0.02 to 1.25 fibers per ml as a working range. In the new OSHA Standards published in the FEDERAL REGISTER on June 20, 1986, NIOSH Method 7400 is listed under their Mandatory Appendix A as an essential monitoring method. While there was only limited information available at the June 1986 Meetings on the OSHA Standard (the Standard had not then been published in the FEDERAL REGISTER) it had been noted that NIOSH Method 7400 was considered an essential method for counting asbestos fiber concentrations. At the Meeting, Ms. Grisham of Nuturn volunteered to send the Institute a copy of Method 7400 for distribution to Institute Members. A copy is enclosed. For your information.
E. W. Drislane Executive Director Distribution:
Delegates and Alternates H.E.A. Committee
FMSI-0455
FMSI 02332
FORMULA: various
H.W.: various
METHOO: ISSUEO:
FIBERS 7400 2/15/84
OSHA: 0.5 asbestos fibers (> 5 pm long)/ml
PROPERTIES: solid,
NIOSH: 0.1 asbestos f/ml [1]; 3 glass fibers (>10 pm x <3.5 pm)/mL [2]
fibrous
ACGIH: 0.2 crocidolite; 0.5 amosite; 2 chrysotile and other asbestos, f/mL
'
SYNONYMS: asbestos (actinolite [CAS #77536-66-4], grunerite (anosite) [CAS #12172-73-5],
~
anthdphyllite [CAS #77536-67-5], chrysotile [CAS #12001-29-5], crocidolite [CAS #12001-28-4], tremolite [CAS #77536-68-6]); fibrous glass.
fa#'***
SAMPLING
____________________ MEASUREMENT_______
SAMPLER: FILTER (0.8-1.2 pm cellulose ester membrane, 25-nm diameter)
TECHNIQUE: MICROSCOPY, PHASE CONTRAST ANALYTE: fibers (manual count)
FLOW RATE*: > 0.5 L/min
SAMPLE PREPARATION: acetone/triacetin method
VOL-MIN*: 400 L 9 0.1 fiber/mL
-MAX*: 1920 L 9 0.1 fiber/mL
Adjust for 100 to 1300 fibers/mm2 (step 4)
SHIPMENT: routine
SAMPLE STABILITY: indefinite
BLANKS: 10X of samples (minimum 2) [3]
ACCURACY
RANGE STU0IED: 80 to 100 fibers counted
BIAS: see EVALUATION OF METHOO
. *.
OVERALL PRECISION (sr): 0.115 to 0.13 [3]
(A Rules)
COUNTING RULES: Set A (P4CAM 239 [3,4]) or Set B (modified CRS [5])
EQUIPMENT: 1. phase-contrast microscope 2. Walton-8eckett graticule (100 pm field diameter): A Rules use G-22; B Rules use Type G-24 3. phase-shift test slide (HSE/NPL)
CALIBRATION: phase-shift detection limit about 3 degrees [7]
RANGE: 100 to 1300 fibers/mma filter area [6]
ESTIMATED LOO: 7 fibers/tmt2 filter area
PRECISION: 0.10 to 0.12 [3] (A Rules)
APPLICABILITY: The working range is 0.02 fiber/mL (1920-L air sample) to 1.25 fibers/mL (400-L
air sample). The method gives an index of airborne asbestos fibers but may be used
for other materials such as fibrous glass by inserting suitable parameters into the counting rules. The method does not differentiate between asbestos and other fibers. Asbestos fibers less than ca. 0.25 um diameter will not be detected by this method [7], INTERFERENCES: Any other airborne fiber may interfere since all particles meeting the counting criteria are counted. Chain-like particles may appear fibrous. High levels of non-fibrous dust particles may obscure fibers -in the field of view and raise the detection limit. OTHER METHOOS: This method introduces changes for improved sensitivity and reproducibility and replaces P&CAM 239 [3.41.
2/15/84
7400-1
FMSl 02333
FIBERS
HETHOO: 7400
REAGENTS:
EQUIPMENT:
1. Acetone.*
1. Sampler: fijGld i^Uor^5 .irmee-piece cassette
C4* 2. Triacetin (glycerol triacetate),
with SO-nm^extension ^owl with cellulose ester filter,
reagent grade.
0.8 to 1.2^pm pore size and baclcup pad. NOTE: Analyze representative filters for fiber
*See Special Precautions.
background before use and discard^the filter lot if
more than S fibers/100 fields are found.
.2. Personal sampling punp, > O.S L/min (see step 4 for
flow rate), with flexible connecting tubing.
3. Microscope, phase contrast, with green or blue filter,
8 to 10X eyepiece, and 40 to 45X phase objective (total
magnification ca. 400X); numerical aperture 0.65 to
0.75.
.
4. Slides, glass, single-frosted, pre-cleaned, 25 x 75 inn. 5. Cover slips, 2S x 25 mm, no. 1-1/2, unless otherwise .
specified by microscope manufacturer.
6. Knife, #10 surgical steel, curved blade.
.
.7. Tweezers.
'" --
8 Flask, Guth-type, insulated neck, 250 to 500 ml (with
single-holed rubber stopper and elbow-jointed glass
tubing, 16 to 22 cm long).
-
9. Hotplate,.spark-free, stirring type; heating mantle; or
infrared lamp and magnetic stirrer.
.10 Syringe, hypodermic, with 22-gauge needle.
11. Graticule, Walton-Geckett type with 100 pm diameter
circular fitd~at-the specimen plane (area 0.00785 <nn3) (Type G-22 for A Rules; Type G-24 for B Rules).
Available from Graticules Ltd., Worley Road, Tonbridge
TN9 1RN, Kent, England (Telephone 011-44-732-359061). NOTE: The graticule is custcm-made for each microscope.
Specify disc diameter needed to fit exactly the
ocular of the microscope and the diameter (mm) of
, the circular counting area (see step 11).
,_____ 12. HSE/NPL phase contrast test slide, Mark II. Available ITfcl ^rdW^PTR Optics Ltd., 145 Newton Street, Waltham, MA
02154 (Telephone (617) 891-6000). 13. Telescope, ocular phase-ring centering. 14. Stage micrometer (0.01 mm divisions).
SPECIAL PRECAUTIONS: Acetone is an extremely flammable liquid and precautions must be taken not to ignite it. Heating of acetone must be done in a ventilated laboratory fume hood using a flameless, spark-free heat source.* 1 2
SAMPLING: 1. Calibrate each personal sanpling pump with a representative sanpler in line [3]. 2. Fasten the sampler to the worker's lapel as close as possible to the worker's mouth.
Remove the top cover from the end of the cowl extension (open face) and orient face down. Wrap the joint between the extender and monitor body with shrink tape to prevent air leaks.
-eyw7*8*
7400-2
FMS1 02334
HETHOO: 7400
FIBERS
3. Submit at least two field blanks (or 101 of the total samples, whichever is greater) for.
each set of sanples. Remove the caps from th^-field blank cassettes and store the caps and cassettes in a clean area (bag or box) during the sanpling period. Replace the caps in the cassettes when sanpling is completed. 4. Sample at O.S L/min or greater [8]. Do not exceed 1 mg total dust loading on the filter. Adjust sampling flow rate, Q (L/min), and time to produce a fiber density, E (fibers/nm2), of 100 to 1300 fibers/mm2 [3.85 104 to 5 105 fibers per ZS-mn filter yith effective collection area (Ag= 38S mm2)] for optimun counting precision (see step 21). Calculate the mininua sampling time, t^n (min), at the action level (onerhalf the current standard), l (fibers/mt), of the fibrous aerosol being sampled:
tjnin
(Ag) (E) (Q) (L) 103
5. Remove the field monitor at the end of sampling, replace the plastic top cover and small
end caps, and store.the monitor.
'
6. Ship the samples in a rigid container with sufficient packing material to prevent jostling
or damage.
NOTE: Oo not use polystyrene foam in the-shipping container because of electrostatic forces
which may cause fiber loss from the sampler filter.
SAMPLE PREPARATION: NOTE: The object is to produce samples with a smooth (non-grainy) background in a mediun with a
refractive index equal to or less than 1.46. The method below collapses the filter for
easier focusing and produces permanent mounts which are useful for quality control and
interlaboratory comparison. Other mounting techniques meeting the above criteria may also be used (e.g., the non-permanent field mounting technique used in P&CAM 239 [1,3,4]}.
7. Ensure that the glass slides and cover slips are free of dust and fibers. 8. Place 40 to 60 mL of acetone into a Guth-type flask. Stopper the flask with a single-hole
rubber stopper through which a glass tube extends S to 8 cm into the flask. The portion of the glass tube which exits the top of the stopper (8 to 10 an) is bent downward in an elbow
which makes an angle of 20 to 30* with the horizontal. 9. Place the flask on a stirring hotplate or wrap in a heating mantle. Heat the acetone
gradually to its boiling temperature (ca. 58 C).
CAUTION: The acetone vapor must be generated in a ventilated fune hood away from all open
flames and spark sources. Alternate heating methods can be used, providing no
open flame or sparks are present.
10. Mount either the whole sample filter or a wedge cut fran the sample filter on a clean glass
slide. a. Cut wedges of ca. 251 of the filter area with a curved blade steel surgical knife using
a rocking motion to prevent tearing. b. Place the filter or wedge, dust side up, on the slide. Static electricity will usually
keep the filter on the slide until it is cleared.
'
c. Hold the glass slide supporting the filter approximately 1 to 2 cm from the glass tube
port where the acetone vapor is escaping from the heated flask. The acetone vapor stream should cause a condensation spot on the glass slide ca. 2 to 3 cm in diameter.
Move the glass slide gently in the vapor stream. The filter should clear in 2 to 5
sec. If the filter curls, distorts or is otherwise rendered unusable, the vapor stream is probably not strong enough. Periodically wipe the outlet port with tissue to prevent
liquid acetone dripping onto the filter.
.
2/15/84
7400-3
FMSI 02335
IT
FIBERS
HETHOO: 7400
d. Using the hypodermic syringe with a 22-gauge needle, place 1 to 2 drops of triacetin on
the filter. Gently lower a clean 25-mm square cover slip down onto the filter at a
slight angle to reduce the possibility of forming bubbles. If too many bubbles form or
the amount of triacetin is insufficient, the cover slip may become detached within a few
hours.
<
e. Glue the edges of the cover slip to the glass slide using a lacquer or nail polish [9].
NOTE: If clearing is slow, the slide preparation may be heated on a hotplate (surface
temperature 50 C) for 15 min to hasten clearing. Counting may proceed
inmediately after clearing and mounting are completed.
CALIBRATION AND QUALITY CONTROL:
-
11. Calibration of the Walton-Beckett graticule. The diameter, d,. Gim), of the circular
counting area and the disc diameter must be specified when ordering the graticule.
a. Insert any available graticule into the eyepiece and focus so that the graticule lines
are sharp and clear.
b. Set the appropriate interpupillary distance and, if applicable, reset the binocular head
adjustment so that the magnification remains constant.
c. Install the 40 to 4SX phase objective.
d. Place a stage micrometer on the microscope object stage and focus the microscope on the
graduated lines.
e. Measure the magnified grid length, L0 (pm), using the stage micrometer.
f. Remove the graticule from the microscope and measure its actual grid length, La (ran).
This can best be accomplished by using a stage fitted with verniers.
g. Calculate the circle diameter, (mm), for the Walton-Bedcett graticule:
La x D.
Example: If Lo * 108 pm, La 2.93 mm and 0 100 pm, then dc = 2.71 im.
- h. Check the field diameter, 0(acceptab1e range 100 pm 2 pm) with a stage micrometer
. upon receipt of the graticule from the manufacturer. Determine field area (mn2).
12. Microscope adjustments. Follow the manufacturer's instructions and also the following:
a. Adjust the light source for even illunination across the field of view at the condenser
iris.
NOTE: Kohler illumination is preferred, where available.
.-
b. Focus on the particulate material to be examined.
c. Hake sure that the field iris is in focus, centered on the sample and open only enough
to fully illuminate the field of view.
d. Use the telescope ocular supplied by the manufacturer to ensure that the phase rings
(annular diaphragm and phase-shifting elements) are concentric.
13. Check the phase-shift detection limit of the microscope periodically.
a. Remove the HSE/NPL phase-contrast test slide from its shipping container and center it
under the phase objective.
b. Bring the blocks of grooved lines into focus.
NOTE: The slide consists of seven sets of grooves (ca. 20 grooves to each block) in
descending order of visibility from sets 1 to 7. The requirements for asbestos
counting are that the microscope optics must resolve the grooved lines in set 3
carp1etely, although they may appear somewhat faint, and that the grooved lines in
sets 6 and 7 must be invisible.
a and s. ---t he it lrast p^-^ally visihle
but mav vary slichtlv in visibility between microscopes. A microscope which fails
to meet these requirements has either too low or too high a resolution to be used
for achoctrre rrajptim).
2/15/84
7400-4
FMSI 02336
METHOO: 7400
FIBERS
c. If the image quality deteriorates, clean the microscope optics and if the problem persists, consult the microscope manufacturer.
14. Quality control of fiber counts.
a. Prepare and count field blanks along with the field samples. Report the counts on each
blank. Calculate the mean of the field blank counts and subtract this value from each sample count before reporting tho rpcnltc
NOTE 1: The identity of the blank filters should be unknown to the counter until all
' counts have been completed.
'
NOTE 2: If a field blank yields fiber counts greater than 7 fibers/100 fields, report
possible contamination of the sanples.
b. Perform blind recounts by the same counter on 101 of filters counted (slides relabeled
by a person other than the counter).
15. Use the following test to determine whether a pair of counts on the same filter should be
rejected because of possible bias. This statistic estimates the counting repeatability at
the 951 confidence level. _Discard the sample if the difference between the two counts
exceeds 2.77 (F)sr, where F * average of the two fiber counts and sr = relative
standard deviation, which should be derived by each laboratory based on historical in-house
data.
NOTE: If a pair of counts is rejected as a result of this test, recount the remaining
sanples in the set and test the new counts against the first counts. Discard all
rejected paired counts.
16. Enroll each new counter in a training course which compares performance of counters on a
variety of sanples using this procedure.
NOTE: To ensure good reproducibility, all laboratories engaged in asbestos counting should
participate in an asbestos proficiency testing program such as the NIOSH Proficiency
Analytical Testing (PAT) Program and routinely-participate with other asbestos fiber
counting laboratories in the exchange of field samples to compare performance of
counters.
MEASUREMENT: 17. Place the slide on the mechanical stage of the calibrated microscope with the center of the
filter under the objective lens. Focus the microscope on the plane of the filter. 18. Regularly check phase-ring alignment and Kohler illunination [7]. 19. Select one of the following sets of counting rules:
NOTE: The two sets of rules have been demonstrated to produce equivalent mean counts on a variety of asbestos sample types [5] and must be strictly followed in order to obtain valid results. No hybridizing of the two sets of rules is permitted. The calibration of the microscope with the HSE/NPL test slide determines the minimum detectable fiber diameter (ca. 0.25 pm),
a. A Rules (same as P&CAM 239 rules Cl>3,4]). NOTE: The A Rules are required for monitoring asbestos for compliance purposes under
OSHA or NIOSH standards. 1. Count only fibers longer than 5 pm. Measure the length of curved fibers along the
curve. 2. Count only fibers with a length-to-width ratio equal to or greater than 3:1. 3. For fibers which cross the boundary of the graticule field, do the following:
a. Count any fiber longer than 5 pm which lies entirely within the graticule area. b. Count as 1/2 fiber any fiber with only one end lying within the graticule area. c. Do not count any fiber which crosses the graticule boundary more than once.
d. Reject and do not count all other fibers.
2/15/84
7400-5
FMSI 02337
FIBERS
HETHOO: 7400
4. Count bundles of fibers as one fiber unless individual fibers can be identified by observing both ends of a fiber.
5. Count enough graticule fields to yield 100 fibers. Count a mininun of 20 fields. Stop at 100 fields regardless of fiber count.
b. B Rules
NOTE: The B Rules are preferred analytically because of their demonstrated ability to improve the reproducibility of fiber counts [51.
1. Count only ends of fibers. Each fiber must be longer than S pm and less than 3 pm diameter.
2. Count only ends of fibers with a length-to-width ratio equal to or greater than 5:1. 3. Count each fiber end which falls within the graticule area as one end, provided that
the fiber meets rules b.l and b.2. 4. Count visibly free- ends which meet rules b.l and b*2 when the fiber appears to be
attached to another particle, regardless of the size of the other particle. 5. Count the free ends of fibers emanating from large clumps and bundles up to a maximum
of 10 ends (5 fibers), provided that each segment meets rules b.l and b.2. 6. Count enough graticule fields to yield 200 ends. Count a minimum of 20 fields. Stop
at 100 fields, regardless of the fiber count. 7. Oivide the total end count by 2 to yield fiber count.
NOTE: Split fibers will normally be counted as more than two ends if the free ends meet the rules b.l. and b.2.
20. Start counting from one end of the filter and progress along a radial line to the other end, shift either up or down on the filter and continue in the reverse direction [10]. Select fields randomly by looking away from the eyepiece briefly while advancing the mechanical stage. When an agglomerate covers ca. 1/6 or more of the field of view, reject the field and select another. Oo not report rejected fields in the number of total fields counted. NOTE: When counting a field, continuously scan a range of focal planes by moving the fine focus knob to detect very fine fibers which have become embedded in the filter. The small-diameter fibers will be very faint but are an important contribution to the total count.
CALCULATIONS: 21. Calculate and report fiber density on the filter, E (fibers/nra2), by dividing the total
fiber count, F, minus the mean field blank count, B, by the number of fields, n, and the field area, Af (0.00785 mo2 for a properly calibrated Ua1ton-8eckett graticule):
E fibers/mn2.
22. Calculate the concentration, C (fibers/mL), of fibers in the air volume sampled, V (L), using the effective collection area of the filter, Ac (385 tra2 for a 25-mm filter):
r - tE)<Ac) V-10*
NOTE: Periodically check and adjust the value of Ac, if necessary.
EVALUATION OF NETHOO: This method is a revision of NI0SH Method P&CAM 239 [1,3,4]. A summary of the revisions is as follows:
2/15/84
7400-6
FMSI 02338
METHOD: 7400
FIBERS
A. Sampling
The change from a 37-mm to a 25-nro filter size was incorporated to improve sensitivity and reduce problems associated with non-uniform fiber loading reported on the 37-rnn filters
[10]. The change in flow rates allows for 2 m3 full-shift samples to be taken, providing that the filter is not overloaded with non-fibrous particulates. The collection efficiency of the sampler is not affected by changes in flow rate in the range 0.5 to 16 L/min [8].
B. Sample Preparation Technique The acetone vapor-triacetin preparation technique has been incorporated in the method as a faster, more permanent mounting technique than the dimethyl phthalate/diethyl oxalate method of P&CAM 239 [1,3,4,11],
C. Measurement
1. The inclusion of the Wa1ton-8eckett graticule in the method was made to standardize the field area observed through the eyepiece [6,11].
2. The introduction of the HSE/NPl test slide was made to standardize microscope optics for sensitivity to fiber diameter [7,11].
3. A recent international collaborative study involved 16 laboratories using prepared slides from the asbestos, cement, milling, mining, textile, and friction material industries [5]. The relative levels of count by different counting rules were:
Samole Tvoe
Nuntoer of Samples
Asoect Ratio >3:1 AIA Hod. CRS*
Asoect Ratio > 5:1 AIA Mod. CRS*
Mining Hilling Asbestos Cement Textile Chrysotile Friction Material Others (Insulation, Amosite)
10 10 14 10 10 6
100 100 100 100 100 100
127 74 112 84 146 90 109 89 130 87 127 92
92 9S 137 99 116 118
TOTAL: 60 MEAN: 100
lis 86
Tip
Arithmetic means of counts made by different laboratories relative to the AIA counts.
The modified CRS (NIOSH B) Rules were found to be mbre precise than the AIA (NIOSH A)* Rules. The ranges of relative standard deviations (sr) which varied with sanple type and laboratory were:
_________________________ sr
Intralaboratorv
Interlaboratory
Overal 1
AIA (NIOSH A Rules)* Modified CRS (NIOSH 8 Rules)
0.12 to 0.40 0.11 to 0.29
0.27 to 0.8S 0.20 to 0.3S
0.46 0.25
Under AIA rules, only fibers having a diameter less than 3 pm are counted and fibers attached to particles larger than 3 pm are not counted. NIOSH A Rules are otherwise similar to the AIA rules.
The B Rules have also been favorably received by analysts as less ambiguous and simpler to use; these rules also showed the least bias relative to AIA rules in the collaborative study. An independent NIOSH laboratory study using amosite fibers
reported a relative standard deviation, including within- and between-sample
2/15/84
7400-7
FMSI 02339
T
FIBERS
HETHOO: 7400
variability, of 0.157 for the B Rules [12]. Adding an estimated sampling pump error, sr,
of 0.05 [13] to the within-sample variability in this study results in an estimate of overall precision, s,., of 0.102 for the B Rules.
4. Because of past inaccuracies associated with low fiber counts, the minimun loading has been increased to 100 fibers/mm? filter area (80 fibers total count). This level yields an overall s,. = 0.13, as indicated in Figure 3 (revised) of P&CAM 239 [3,4] which
corresponds to a measurement sr * 0.12 after removal of pump error [13]. Similarly, at the maximum count of 100 fibers, overall sr *0.115 and measurement sr * 0.10 are obtained.
0. Evaluation of the method using the A and 8 counting rules will proceed on a continuing basis through the NIOSH Proficiency Analytical Testing (PAT) Program. The new PAT reporting form allows for reporting of results by either set of rules as of January, 1984.
REFERENCES:
'_
[1] Revised Recaimended Asbestos Standard, U.S. Department of Health, Education, and Welfare,
Publ. (NI05H) 77-169 (1976).
[2] Criteria for a Recaimended Standard...Occupational Exposure to Fibrous Glass, U.S.
Department of Health, Education, and Welfare, Publ. (NIOSH) 77-152 (1977).
[3] Lei del, N. A., S. G. Bayer, R. 0. Zunwalde, and K. A. Busch. USPKS/NIOSH Membrane Filter
Method for Evaluating Airborne Asbestos Fibers, U.S. Department of Health, Education, and
Welfare, Publ. (NIOSH) 79-127 (1979).
[4] NIOSH Manual of Analytical Methods, 2nd. ed., V. 1., P&CAM 239, U.S. Department of Health,
Education, and Welfare, Publ. (NIOSH) 77-1S7-A (1977).
[5] Crawford, N. P., H. L. Thorpe, and W. Alexander. "A Comparison of the Effects of
Different Counting Rules and Aspect Ratios on the Level and Reproducibility of Asbestos .
Fiber Counts," Part I: Effects on Level (Report No. TH/82/23), Part II: Effects on
Reproducibility (Report No. TM/82/24), Institute of Occupational Medicine, Edinburgh,
Scotland (December, 1982).
[6] Walton, W. H. "The Nature, Hazards, and Assessment of Occupational Exposure to Airborne
Asbestos Oust: A Review," Ann. Occuo. Hyg.. 25. 115-247 (1982).
[7] Rooker, S. 0., N. P. Vaughn, and 0. M. LeGuen. "On the Visibility of Fibers by Phase
Contrast Microscopy," Amer. Ind. Hyg. Assoc. 0., 43, 505-515 (1982).
[8] Johnston, A. N., A. 0. Jones, and J. H. Vincent. "The Influence of External Aerodynamic
Factors on the Measurement of the Airborne Concentration of Asbestos Fibres by the
Membrane Filter Method," Ann. Occuo. Hyg.. 25, 309-316 (1982).
[9] Asbestos International Association, AIA Health and Safety Recaimended Technical Method #1
(RTHI). "Airborne Asbestos Fiber Concentrations at Workplaces by Light Microscopy"
(Membrane Filter Method), London (1979).
[10] Hooke, H. B., C. E. Feigley, and 0. A. Ludwig. "Interwedge Variation in the Membrane
Filter Method for Airborne Asbestos Fibers," Amer. Ind. Hyg. Assoc. J., 44, 542-546 (1983).
[11] Chatfield, E. J. Measurement of Asbestos Fibre Concentrations in Workplace Atmospheres,
Royal Caimission on Hatters of Health and Safety Arising from the Use of Asbestos in
Ontario, Study No. 9, 180 Oundas Street West, 22nd Floor, Toronto, Ontario, CANADA MSG 1ZB.
[12] Taylor, 0. G., P. A. Baron, S. A. Shulman and J. W. Carter. "Identification and Counting
of Asbestos Fibers," Am. Ind. Hyg. Assoc. J. 45(2), 84-88 (1984).
[13] Busch, K. A. and 0. G. Taylor. "Statistical Protocol for the NIOSH Validation tests".
Chemical Hazards in-the Workplace, Measurement and Control, ACS Symposiun Series 149,
American Chemical Society, Washington, 0C (1981).
HETH00 REVISED BY: James W. Carter. David G. Taylor, Ph.O., CIH, and Paul A. Baron, Ph.D., NIOSH/OPSE; based on the revised Method P&CAM 239 [1,3,4].
2/15/84
7400-8
FMSI 02340
TT