Document reKRGBn08oEaa9qBXM2mYxwL0

technical catalog bulle A**' 3^*7 new G-40 qas boiler--reduces costs and installation time The new G-40 gas boiler by American-Standard is suit able for installation in larger residences and small apart ment and commercial buildings. Designed for both hot water and steam installations, it can be furnished with a tankless type, internal, domestic water heater tor either application. An attractive two-tone boiler jacket gives the G-40 a clean, streamlined appearance. Ruggedly constructed of durable cast iron, the new G-40 is available in 3 to 14 section sizes with A.GA design certified outputs from 120,000 to 780,000 btu/hr. All sections are tested for 50 psi water working pressure. On-site assembling time can be decreased by ordering up to 14 sections pre-assembled, with or without factoryinstalled tankless heater. An exclusive built-in air eliminator-the ELIMINAIRE-is furnished on all boilers, specifically for hot water installations, saving the addi tional expense of an external device. The G-40 is provided with two 3' top flow tappings and two 3" return flow tappings to allow flexibility in de signing system piping when the G-40 is installed in con fined areas. For further convenience, complete manifold and all controls are shipped factory assembled. Self energizing controls and electronic controls are available as options. 1-Eliminaire*-is a patented cost-saving feature of the G-40. This unique built-in air eliminator is integrally cast into the left hand end section. Furnished in all boilers, specifically for hot water installations, the ELIMINAIRE baffle diverts rising air bub bles into a tapping for connection to the expansion tank. No external device is required to separate air and water-thus reducing both costs and installation time. 2-controls-mounted on front and left side of boiler for easy adjustment and mainte nance. Optional electronic controls and selfenergizing controls available. 3-water heater-large, finned copper coil tankless type available for steam or water installations. Inserted where hottest water is in contact with heater coil. 4- tappings-two 3" supply (top) and two 3" return tappings (side) simplify piping hook-up. 5- jacket-sturdy steel with smart beige and brown finish, modern square corners. Inner surfaces protected with heavy glass fiber msulation-prevents wasteful heat loss, keeps jacket cool. 6- built-in draft hood-completely enclosed in jacket; eliminates unsightly protrusion in rear of boiler. 7- cast iron sections--multiple pin-like pro jections for maximum heat extraction. Tested for 50 psi water working pressure. End sec tions designed with extended legs to elim inate need for separate base. 8- burners-precision made and factory tested to assure quiet, efficient operation with all gases. Cast iron, drilled port burners supplied for natural gas. Cleanable ribbon burners standard for propane gas. 9- factory assembled manifold and controls --only requires attachment to boiler. Com pletely enclosed by jacket. ratings (natural and propane gases). for 1Munitions from tea love to 2000 ft cir- beller number no. of sectlene no. of burners A.6JL ratings Input (Stu/hr) output (Btulhr) nit 1 = 8 = 11 ratings* wattr (Btu/tir) itum (sq. ft.) staam (Btu/hr) chinIMF dlamatar (Inehat) heicht (fait) G-403 G-404 <3-405 G-406 G-407 G-406 G-409 <3-4010 G-4011 G-4012 G-4013 G-4014 3 4 s 6 7 8 9 10 11 12 13 14 2 150,000 120,000 104,300 375 90,000 3 225,000 180,000 156,500 563 135.000 4 300,000 240,000 208,700 750 180,000 5 375,000 300,000 260,900 938 225,100 6 450,000 360.000 313,000 1125 270.100 7 525,000 420,000 365,200 1313 315,100 8 600,000 480,000 417,400 1500 360,100 9 675,000 540,000 469,600 1688 405.100 10 750,000 600,000 521,800 1875 450,000 11 825,000 660,000 574,000 2063 495,200 12 900.000 720,000 626,200 2250 540,000 13 975,000 780,000 678,400 2438 585,100 8 8 8 10 10 10 10 12 12 12 12 15 For altitudes above 2000 ft, ratings should ba induced at tha rata ef4% tar aach 1000 ft abova m level. Nat l a 8 = R ratings shown are on a Dipin* and pick up allowance of 1J3S for iteam and 1.15 lor watar. Amariean-SUndard should ba consulted before selecting a bollar tar Inatallatlona havlni unusual plplnt and pick up requirements. 15 15 15 15 IS IS 15 15 15 15 15 15 ft 0-40 tankless heater ratings iorr rfse In temperature trlth 300*F bollar witar tamparatura (guana par mlntrta) r staam pollar-haatar combinations shown shodod. extra aquoatat In ri(ht and sactlan Is racommandad G-40 gas boilers by American-Standard have ratings approved by the Institute of Boiler and Radiator Manufacturers. The boilers are constructed to the specifications of the American Society of Mechanical Engineers and are design certified by the American Gas Association. The G-40 bears the l=B=R, A.S.M.E. and A.GA symbols. All sizes of the G-40 are available In models for forced and gravity hot water, and steam systems. sample specification for G-40 Contractor shall furnish and install, as indicated on plans, ............ gas fired boiierfs), having an input of.............Btuh and a gross output of............ Btuh when fired with............. gas. Boiler(s) shall be constructed of cast iron in accord ance with A.S.M.E. requirements for low pressure heating boilers and bear the A.S.M.E. symbol. Boiierfs) shall be A.GA design certified and have l=B=R approved ratings. Boiierfs) shall be furnished with an air elimination device integrally cast into the left hand end supply tapping. Boiierfs) shall be composed of cast iron sections with ver tical flues and furnished with one atmospheric drill port or removable ribbon burner per flueway. Boiierfs) shall be supplied by manufacturer with one main automatic dia phragm gas valve, safety pilot with thermocouple and additional lighting pilots as required, one gas pressure regulator (except for propane gas), high limit control, and integral canopy and drafthood. Water or steam trim as required. Boiierfs) shall be supplied with internal type tankless heater capable of supplying...............gallons per minute at a 100'F rise in temperature. 00868 3 * W *d p lN e ;i boiler number gravity supply return On.) On.) iSIwSS mppfy ratorn On.) On.) to UR*y man 0-403 0-404 0-403 0406 0-407 2 2 2% (9-2 (2)-2 2 2 2% (2>-2 (21-2 1% 1% 2 2 2 m 1% 2 2 2 boiler number rtsar 0*J return Onj header On.) squal lier On.) H 0-408 <2}-2 (9-2 2% 0-409 (2}-2Vk (2)-2% 2% 2% 2% 0-406 m-2 1% 4 1% 3-409 (2>-2 1% 4 2 0-4010 (2)-2% (2)-2% 2% 2% 3-4010 (9-3 1% 4 2 0-4011 (2J-3 (2J-2VS 3 3 0-4011 (29-3 1% 4 2 0-4012 (2V3 (9-2% 3 3 0-4012 (2X3 1% 4 2 0-4013 (2V3 (9-2% 3 3 0-4013 (9-3 1% 4 2 G-4014 (2>3 (2)-2% 3 3 0-4014 (2W 1% 4 2 NOTE: Left hand supply connection featuring the ELIMINAIRE is used on water boilers. Limit control should also be placed In the left hand section. Where both outlets and return are used on gravity systems, make respective supply and return connection at opposite ends of the boiler. - -aS .. gas control and connection sizes; pertinent data boiler number water content (peundt) water (team apprax. weigm (pounds) alia of mtnHeld (1achat) net. & propane gaaaa 3-403 0404 0405 0406 0407 0408 0409 04010 04011 04012 04013 04014 2204 2814 3414 4014 461.6 521.8 582.0 642.2 7224 782.6 8424 9034 1644 209.9 2S54 300.9 3464 391.9 437.4 482.9 5284 573.9 6194 664.9 856 1027 1196 1370 1544 1713 1880 2050 2219 2388 2557 2726 Pressure regulator net furnished for Present tea. 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% pranura regulators (Inches) net % % 1 1 1 1 1% 1% 1% 1% 1% 1% automatic gaa aahre, gaa connections and manual shutoff reive site* (Inches) nat propane %% %% i% i% i% i% i% i i% i i% i i% i mi i% i AMERICAN STANDARD 4 00869 G-40 gas fired boilers orifice drill sizes umer-sir saa'leveli la (Mi) too too 1000 1100 1200 too 80. 700 af(S* Bta oa.ft~ m.(b m &ittr ea.fi. jWt aa.lt pfopono pi 780 too 2800 sm. liBtn &.it ea.lt 75,000 75,000 75,000 75,000 75,000 75,000 0.60 0.65 0.70 OJO 0.90 1.53 21 24 20 19 21 M 7 4 3 wr*. 41, NOTE) Sm level retinae am to be m etevadone between 0 and 2400 ft Fbr uao ft, toa level retinae should bo reduced at die nte of 4% for oacti 1400 ft`above: ure r-f '/vJ,'* manifold *ea^| praesura OltHiO) natural1; . BOO^IUO propane 2800 MWIf1 fM too-too u 11.0 3.0 ebeatinavaiua of pea at oea Mol. ,* (*o*F mb la H| AMERICAN STANDARD 00870 G-40 gas fired boiler* AMERICAN STANDARD PLUMBING / HEATING on ny imi sfw BRUNSWICK, n. I. OA903 00871