STANDARD OPERATING PROCEDURE Calculation of the 24-hour average concentration of Vinyl Chloride leaving the Stripping System in ppm on a Dry Resin Basis The calculation is as follows:
<JCC 101797
Where: A = 24-hour average concentration of Vinyl Chloride leaving
the stripping system in ppm on a dry resin basis. T = Type T resin means resin produced by the solvent process. K = Total number of grades of resin produced during the 24-hour
period. L = Total number of times that samples were taken during the
production of the grade resin in the 24-hour period. G = Garde of resin e.g., G,. G2. P = Flow rate of stripped varnish to the field storage tanks
lb/hour. M = Concentration of Vinyl Chloride in the stripped varnish
sample in ppm. F = Flow rate of the rectifying column tails to solvent
recover in Ib/hour. C = Concentation of Vinyl Chloride in the rectifying column
tails going to solvent recovery in ppm. Qt = Total production of type T resin over the 24-hour period.
P = is calculated using this formula: P = T + A + E- (V + S + B + D)
Where: T = Total autoclave feeds in lb/hour. A = Acetone flow to the acetone vaporizer in 16/hour. V = Vinyl Chloride make in lb/hour. S = Acetone to solvents in lb/hour. B = Acetone to B-3 in lb/hour. D = Acetone from rectifying column tails to dilution tank in lb/hour. E = Acetone from 2708 tank to dilution tank in lb/hour.
UCC 101798
Q is calculated using this formula: T
Where: R = Percent total solids in the stripped va ish as a weight percent.
UCC 101799
be:
Mr. T. D. Epps* Mr. J. F. Erdmann Mr. C. E. Fry Mr. R. E. George Mr. M. E. Griffith Mr. R. T. Kramer* Mr. R. J. Murawski Mr. G * G. Weissert Mr. R. N. Wheeler,
Note to be recipients:
Resin A is VYLF Resin B is VMCA Resin C is VROH Resin D is VYHG Resin E is VYHG
^Circulated Copies
UCC 101800