Document reDBOJ4pNm5pGGNOQw8p7yeKJ

3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Final Report Analysis of PFOA, PFBS, PFHS, and PFOS in Aqueous Samples from 3M Decatur, Alabama: Groundwater Treatment Plant GAC System January 2014 Laboratory Request Number: ISO14-07-01 Method Requirement: 3M Method ETS-8-044.1 Report Date - Date of Last Signature Testing Laboratory 3M EHS&S Operations 3M Environmental Laboratory Building 260-5N-17 Maplewood, MN 55144-1000 Requester Gary Hohenstein 3M Building 224-5W-03 Saint Paul, MN 55144-1000 Phone: (651) 737-3570 The testing reported herein meet the requirements of ANSI/ISO/IEC 17025:2005 "General Requirements for the Competence of Testing and Calibration Laboratories", in accordance with the A2LA Testing Certificate # 2052.01. Additionally, the laboratory's quality system has been audited and was determined to be in conformance with the EPA GLPs (40 CFR 792) by an independent A2LA assessment. PAGE 1 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 3M Environmental Laboratory 3M Environmental Laboratory Technical Director: William K. Reagen, Ph.D. 3M Principal Analytical Investigator: Susan Wolf Report Author: Kevin Eich Analytical Report ISO14-07-01 3M Decatur Groundwater T reatment Plant System; January 2014 Sampling Report Date: Date of Last Signature 1 Introduction/Summary The 3M Environmental Laboratory analyzed water samples from the groundwater treatment plant GAC system at the 3M Decatur, AL facility. Water samples were collected by Weston Solutions personnel on January 30, 2014. Samples were returned to the 3M Environmental Laboratory for analysis of Perfluorooctanoate (PFOA), Perfluorobutane sulfonate (PFBS), Perfluorohexane sulfonate (PFHS), Perfluorooctane sulfonate (PFOS) under laboratory project number ISO14-07-01. Analysis of the samples was completed as specified under 3M Environmental Laboratory General Project Outline (GPO) number GPO13-1289. The 3M Environmental Laboratory provided sample containers for seven sampling locations; ACI, ACM2, ACE, WW8R, WW9R, WW10R, and WW11R. The sample set consisted of a field sample, field sample duplicate and a field matrix spike. Each empty container was marked with a "fill to here" line that corresponded to a final volume of 200 mL. Containers reserved for field matrix spikes were fortified with an appropriate matrix spike solution containing all analytes prior to being sent to the field for sample collection. Sample bottles for sampling locations ACM2 and ACE, along with the Trip Blank sample and low spike, were fortified with internal standards and surrogates prior to being sent to the field for sample collection. Samples were prepared and analyzed by method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Select internal standards were used to aid in the data quality objectives. Table 1 summarizes the sample results using the analytical method identified above. All results for quality control samples prepared and analyzed with the samples will be reported and discussed elsewhere in this report. PAGE 2 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 1. Sample Results Summary (1) 3M LIMS ID Sample Description ISO14-07-01-001 ISO14-07-01-002 ISO14-07-01-004 ISO14-07-01-005 ISO14-07-01-007 ISO14-07-01-008 ISO14-07-01-010 ISO14-07-01-011 ISO14-07-01-013 ISO14-07-01-014 ISO14-07-01-016 ISO14-07-01-017 ISO14-07-01-019 ISO14-07-01-020 DAL-GW-ACI-0-140130 DAL-GW-ACI-DB-140130 Average %RPD Sample/Sample Dup DAL-GW-ACM2-0-140130 DAL-GW-ACM2-DB-140130 Average %RPD Sample/Sample Dup DAL-GW-ACE-0-140130 DAL-GW-ACE-DB-140130 Average %RPD Sample/Sample Dup DAL-GW-WW8R-0-140130 DAL-GW-WW8R-DB-140130 Average %RPD Sample/Sample Dup DAL-GW-WW9R-0-140130 DAL-GW-WW9R-DB-140130 Average %RPD Sample/Sample Dup DAL-GW-WW10R-0-140130 DAL-GW-WW10R-DB-140130 Average %RPD Sample/Sample Dup DAL-GW-WW11R-0-140130 DAL-GW-WW11R-DB-140130 Average %RPD Sample/Sample Dup PFOA Concentration (ng/mL) 1550 1610 1580 3.8 0.336 0.320 0.328 (2) 4.9 0.495 0.485 0.490 (2) 2.0 2770 2550 2660 8.3 3090 2710 2900 13 1310 1340 1330 2.3 827 801 814 3.2 PFBS Concentration (ng/mL) 192 211 202 9.4 2710 2620 2670 3.4 0.238 0.276 0.257 (2) 15 348 303 326 14 338 295 317 14 226 274 250 19 170 165 168 3.0 PFHS Concentration (ng/mL) 861 829 845 3.8 0.253 0.212 0.233 (2) 18 0.230 0.207 0.219 (2) 11 1510 1400 1460 7.6 1500 1410 1460 6.2 752 762 757 1.3 362 361 362 0.28 PFOS Concentration (ng/mL) 2670 2720 2700 1.9 1.99 1.84 1.92 (2) 7.8 0.210 0.208 0.209 (2) 0.96 4180 3790 3990 9.8 5050 4540 4800 11 1530 1600 1570 4.5 1570 1500 1540 4.6 NA = Not Applicable (1) Reported results were prepared and analyzed by ETS-8-044.1 using external standard calibration. The analytical method uncertainties associated with the reported results are as follows: PFOA 11 %, PFBS 10%, PFHS 14%, and PFOS 9.0%. (2) Reported results were prepared and analyzed by ETS-8-044.1 using internal standard calibration. The analytical method uncertainties associated with the reported results are as follows: PFOA 16%, PFBS 16%, PFHS 17%, and PFOS 11 %. PAGE 3 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 2 Methods - Analytical and Preparatory 2.1 Methods Analysis was completed using 3M Environmental Laboratory Method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Table 2. Target Analytes Target Analytes Perfluorooctanoic Acid (C8 Acid) Perfluorobutanesulfonate (C4 Sulfonate ) Perfluorohexanesulfonate (C6 Sulfonate) Perfluorooctanesulfonate (C8 Sulfonate) Acronym PFOA PFBS PFHS PFOS Reference Material Structure Linear + Branched Linear Linear Linear + Branched 2.2 Sample Collection Samples were collected on January 30, 2014 in NalgeneTM (high-density polyethylene) bottles prepared at the 3M Environmental Laboratory. Prior to sample collection, bottles designated for field matrix spikes were spiked in the laboratory with a known volume of an appropriate matrix spiking solution containing PFOA, PFBS, PFHS, and PFOS. Sample bottles for sampling locations ACM2 and ACE, along with the Trip Blank sample and low spike, were fortified with a mixture of mass-labeled internal standards at a nominal concentration of 1 ng/mL and a mixture of surrogate recovery standards at a nominal concentration of 0.1 ng/mL. Collected sample bottles were received by the laboratory at ambient conditions on February 11,2014. 2.3 Sample Preparation All samples were diluted with methanol and analyzed for all analytes. The 1:100 dilutions were prepared by removing a 0.1 mL aliquot of the well mixed sample and adding 9.8 mL of methanol and 0.1 mL of a surrogate spiking solution. Prepared samples were analyzed by external standard calibration. The ACE and ACM2 sample sets and the Trip Blank sample and low spike were prepared by removing a 0.4 mL aliquot of the well mixed sample and diluting it with 0.4 mL of methanol (dilution factor of 2). Prepared samples were analyzed by internal standard calibration. During the preparation of the laboratory control samples for internal standard calibration, an aliquot of a separate internal standard spiking solution was added to the laboratory control samples (nominal concentration of 1 ng/mL). The sample bottles for ACE, ACM2, Trip Blank sample and low spike were spiked with an internal standard mix at a nominal concentration of 1 ng/mL prior to being sent to the field for sample collection. The laboratory control samples were analyzed in the same manner as the samples. 2.4 Analysis All samples and quality control samples were analyzed for four target analytes using high performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Pertinent instrument parameters, the liquid chromatography gradient program, and the specific mass transitions analyzed are described in the tables below. Due to the nature of the sample, the wide range of concentrations found in the sample, and the environmental occurrence of multiple isomers of the laboratory's analytes of interest, the software used for processing the analytical results is not able to consistently integrate the analytical peak, manual PAGE 4 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 integration of the analytical peak is necessary. All manual integrations are performed following the procedures outlined in method ETS-12-010. The consistency of the laboratory's integration is ensured through the training of laboratory personnel, the peer review process required for all manual integrations, the review of manual integrations by the QAU, and where necessary the review of manual integrations by laboratory management. Table 3. Instrument Parameters. Instrument Name Analysis Dates Analytical Method Liquid Chromatograph Guard column Analytical column Injection Volume Mass Spectrometer Ion Source Polarity Software ETS Buster 2/14/14 and 2/19/14 ETS-8-044.1 Agilent 1100 Betasil C18 (4.6 mm X 100 mm), 5 u Betasil C18 (4.6 mm X 100 mm), 5 u 10, 50 uL Applied Biosystems API 4000 Turbo Spray Negative Analyst 1.6.1 Table 4. Liquid Chromatography Gradient Program. Step Number 0 1 2 3 4 5 6 7 8 9 Total Time (min) 0.00 0.50 4.00 6.00 11.0 13.0 13.5 16.0 16.5 19.0 Flow Rate (pL/min) 750 750 750 750 750 750 750 750 750 750 Percent A (2 mM ammonium acetate) 90.0 90.0 70.0 70.0 20.0 20.0 10.0 10.0 90.0 90.0 Percent B (Methanol) 10.0 10.0 30.0 30.0 80.0 80.0 90.0 90.0 10.0 10.0 PAGE 5 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 5. Mass Transitions. Analyte Mass Transition Q1/Q3 Internal Standard (1) Mass Transition Q1/Q3 413/369 PFOA 413/219 [13C8]PFOA 421/376 413/169 PFBS 299/80 299/99 [18O2]PFBS 303/84 PFHS 399/99 399/80 [13Cs]PFHS 402/99 499/99 PFOS 499/80 [13C8]PFOS 507/80 499/130 [13C4]PFOA surrogate 417/372 [13C8]PFOA 421/376 [13C4]PFOS surrogate 503/80 [13C8]PFOS 507/80 Dwell time was 50 msec for each transition. The individual transitions were summed to produce a "total ion chromatogram" (TIC), which was used for quantitation. (1) Internal standards were used for the analysis on 2/19/14 3 Data Analysis 3.1 Calibration External Standard Calibration Analysis on 2/14/14: Samples were analyzed against an external standard calibration curve. Calibration standards were prepared by spiking known amounts of the stock solution containing the target analytes into 90:10 methanol: Milli-Q laboratory water. A total of eleven spiked standards ranging from 0.1 ng/mL to 150 ng/mL (nominal) were analyzed. The standards also contained the surrogates at concentrations ranging from 0.1 ng/mL to 25 ng/mL nominal. A quadratic, 1/x weighted, calibration curve of the standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area counts and the resultant calibration curve confirmed accuracy of each curve point. Internal Standard Calibration Analysis on 2/19/14: Samples were analyzed for all analytes against a matrix-matched stable isotope internal standard calibration curve. Calibration standards were prepared by spiking known amounts of stock solutions into 50 mL of 50:50 methanol:laboratory reagent water. The calibration standards contained an internal standard mix at a nominal concentration of 0.5 ng/mL. Calibration standards ranging from 0.0125 ng/mL to 100 ng/mL (nominal) were analyzed (0.0125 ng/mL to 10 ng/mL (nominal) for the SRSs). Low or high points may have been disabled to meet method criteria. A quadratic, 1/x weighted, calibration curve of the ratio of the standard peak area counts over the internal standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area ratios and the resultant calibration curve confirmed accuracy of each curve point. For each calibration curve, the reference standards of PFOA and PFOS used to prepare the calibration standards consisted of both linear and branched isomers. Each curve point was quantitated using the overall calibration curve and reviewed for accuracy. Method calibration accuracy requirements of 10025% (10030% for the lowest curve point) were met for all analytes. The correlation coefficient r was greater than 0.995 for all analytes. PAGE 6 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 3.2 System Suitability A calibration standard was analyzed four times at the beginning of the analytical sequence to demonstrate overall system suitability. The acceptance criteria for system suitability samples is less than or equal to 5% relative standard deviation (RSD) for peak area/ratio and retention time criteria of less than or equal to 2% RSD. These criteria were met for all analytes with the following exceptions: 2/19/14 Analysis: The system suitability area count ratio exceeded 5% for PFBS (8.1%). A method deviation is included with the raw data. 3.3 Limit of Quantitation (LOQ) The LOQ as defined in method ETS-8-044.1 is the lowest non-zero calibration standard in the curve that meets linearity and accuracy requirements and for which the area counts are at least twice those of the appropriate blanks. The LOQs associated with the sample analysis are listed in Table 6. Table 6. LOQ Analyte LOQ, ng/mL 2/14/14 Analysis (1) LOQ, ng/mL 1/9/14 Analysis (2) PFOA 9.58 0.0240 PFBS 10.0 0.0250 PFHS 10.0 0.0250 PFOS 9.27 0.0232 (1) The dilution factor of 100 was applied to the LOQ. (2) The dilution factor of 2 was applied to the LOQ. 3.4 Continuing Calibration During the course of the analytical sequence, several continuing calibration verification samples (CCVs) were analyzed to confirm that the instrument response and the initial calibration curve were still in control. The method acceptance criteria of 100% 25% was met for all analytes. 3.5 Blanks Two types of blanks were prepared and analyzed with the samples: method blanks/solvent blanks and field/trip blanks. Each blank result was reviewed and used to evaluate method performance to determine the LOQ for each analyte. 3.6 Lab Control Spikes (LCSs) Low, mid, and high lab control spikes were prepared for the target analytes and analyzed in triplicate, while only low and high lab control spikes were prepared for the surrogates. LCSs were prepared by spiking known amounts of the analytes into either 10 mL of laboratory-prepared matrix matched water or 1 mL of Milli-Q water to produce the desired concentration. When applicable, the LCSs were then diluted with methanol in the same manner as the samples. Method ETS-8-044.1 states that the average recovery of LCSs at each spiking level be within 80%-120% with a RSD <20%. All LCS samples met method accuracy criteria. All LCSs were used in the determination of the analytical method uncertainty in section 3.7. The following calculations were used to generate data in Table 7. Calculated Concentration * ____ _ LCS Percent Recovery -------------------------------------* 100% Spike Concentration PAGE 7 OF 25 LCS% RSD standard deviation LCS replicates 100% average LCS recovery 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 PAGE 8 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 7. Lab Control Spike Results. ETS-8-044.1 External Standard Calibration Analyzed 2/14/14 Lab ID PFOA (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-140214-1 LCS-140214-2 LCS-140214-3 Average %RSD LCS-140214-4 LCS-140214-5 LCS-140214-6 Average %RSD 0.958 0.958 0.958 9.58 9.58 9.58 1.01 0.943 0.938 101% 4.5% 9.38 9.60 9.32 98.4% 1.4% 106 98.4 97.9 97.9 100 97.3 LCS-140214-7 LCS-140214-8 LCS-140214-9 Average %RSD 38.2 38.2 38.2 37.8 35.9 36.0 95.7% 3.0% 99.0 93.9 94.3 13C4-PFOA surrogate Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery 0.998 0.998 0.998 1.11 1.01 1.16 110% 6.5% 111 102 116 9.98 10.8 9.98 10.5 9.98 10.6 106% 1.4% 108 105 106 ETS-8-044.1 External Standard Calibration Analyzed 2/14/14 Lab ID Spiked Concentration (ng/mL) PFBS Calculated Concentration (ng/mL) LCS-140214-1 LCS-140214-2 LCS-140214-3 Average %RSD LCS-140214-4 LCS-140214-5 LCS-140214-6 Average %RSD LCS-140214-7 LCS-140214-8 LCS-140214-9 Average %RSD 1.00 1.00 1.00 10.0 10.0 10.0 39.8 39.8 39.8 1.05 1.06 1.06 106% 0.55% 10.6 10.4 10.8 106% 1.9% 40.1 39.3 39.8 99.9% 1.2% %Recovery 105 106 106 106 104 108 101 98.7 100 Spiked Concentration (ng/mL) 1.00 1.00 1.00 10.0 10.0 10.0 39.8 39.8 39.8 PFHS Calculated Concentration (ng/mL) 1.08 1.15 1.19 114% 4.9% 10.7 11.4 11.2 111% 3.2% 41.7 39.6 39.6 101% 3.2% %Recovery 108 115 119 107 114 112 105 99.5 99.4 PAGE 9 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 7 continued. Lab Control Spike Results. ETS-8-044.1 External Standard Calibration Analyzed 2/14/14 Lab ID PFOS (Linear + Branched) Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery LCS-140214-1 LCS-140214-2 LCS-140214-3 Average %RSD LCS-140214-4 LCS-140214-5 LCS-140214-6 Average %RSD 0.927 0.927 0.927 9.27 9.27 9.27 0.973 0.935 0.983 104% 2.5% 9.12 9.68 9.58 102% 2.9% 105 101 106 98.4 104 103 LCS-140214-7 LCS-140214-8 LCS-140214-9 Average %RSD 36.9 36.9 36.9 37.8 36.3 38.9 102% 3.2% 102 98.4 105 13C4-PFOS surrogate Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery 0.956 0.956 0.956 1.13 1.19 1.11 120% 3.8% 119 125 116 9.56 10.8 9.56 11.5 9.56 11.2 117% 3.0% 113 120 117 ETS-8-044.1 Internal Standard Calibration Analyzed 2/19/14 Lab ID PFOA (Linear + Branched) Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery LCS-140219-1 LCS-140219-2 LCS-140219-3 Average %RSD LCS-140219-4 LCS-140219-5 LCS-140219-6 Average %RSD 0.190 0.190 0.190 9.50 9.50 9.50 0.186 0.190 0.205 102% 5.1% 11.1 10.2 11.4 115% 5.9% 98.1 100 108 117 107 120 LCS-140219-7 LCS-140219-8 LCS-140219-9 Average %RSD 38.0 38.0 38.0 41.9 38.9 39.4 105% 4.0% 110 102 104 13C4-PFOA surrogate Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery 0.198 0.198 0.198 0.196 0.205 0.221 105% 5.8% 98.9 104 111 1.98 2.35 1.98 2.30 1.98 2.23 116% 2.6% 119 116 113 PAGE 10 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 7 continued. Lab Control Spike Results. ETS-8-044.1 Internal Standard Calibration Analyzed 2/19/14 Lab ID Spiked Concentration (ng/mL) PFBS Calculated Concentration (ng/mL) LCS-140219-1 LCS-140219-2 LCS-140219-3 Average %RSD LCS-140219-4 LCS-140219-5 LCS-140219-6 Average %RSD 0.198 0.198 0.198 9.92 9.92 9.92 0.212 0.211 0.209 106% 0.54% 10.9 9.60 10.7 105% 6.6% LCS-140219-7 LCS-140219-8 LCS-140219-9 Average %RSD 39.6 39.6 39.6 38.9 41.0 39.5 100% 2.4% %Recovery 107 106 106 Spiked Concentration (ng/mL) 0.198 0.198 0.198 110 9.92 96.8 9.92 107 9.92 98.3 39.6 103 39.6 99.7 39.6 PFHS Calculated Concentration (ng/mL) 0.235 0.193 0.214 108% 9.8% 11.2 10.9 11.3 112% 2.4% 38.8 48.5 46.5 112% 11% %Recovery 119 97.7 108 113 109 114 98.0 122 117 ETS-8-044.1 Internal Standard Calibration Analyzed 2/19/14 Lab ID PFOS (Linear + Branched) Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery LCS-140219-1 LCS-140219-2 LCS-140219-3 Average %RSD LCS-140219-4 LCS-140219-5 LCS-140219-6 Average %RSD 0.184 0.184 0.184 9.20 9.20 9.20 0.214 0.202 0.213 114% 3.0% 11.0 9.84 9.64 110% 6.9% 116 110 116 119 107 105 LCS-140219-7 LCS-140219-8 LCS-140219-9 Average %RSD 36.7 36.7 36.7 39.3 41.4 41.8 111% 3.4% 107 113 114 13C4-PFOS surrogate Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery 0.189 0.189 0.189 0.205 0.187 0.220 108% 8.0% 109 98.8 116 1.90 2.17 1.90 222 1.90 2.11 114% 2.6% 114 117 111 PAGE 11 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 3.7 Analytical Method Uncertainty Analytical uncertainty is based on historical QC data that is control charted and used to evaluate method accuracy and precision. The method uncertainty is calculated following ETS-12-012.2. The standard deviation is calculated for the set of accuracy results (in %) obtained for the QC samples. The expanded uncertainty is calculated by multiplying the standard deviation by a factor of 2, which corresponds to a confidence level of 95%. Table 8. Analytical Method Uncertainty. Analyte PFOA PFBS PFHS PFOS PFOA PFBS PFHS PFOS Calibration Method External Standard External Standard External Standard External Standard Internal Standard Internal Standard Internal Standard Internal Standard Standard Deviation (%) 5.59 5.06 6.78 4.51 8.19 8.07 8.59 5.53 Method Uncertainty 11% 10% 14% 9.0% 16% 16% 17% 11% 3.8 Field Matrix Spikes (FMS) A field matrix spike was collected at each sampling point to verify that the analytical method is applicable to the collected matrix. Field matrix spikes are generated by adding a measured volume of field sample to a container spiked by the laboratory with the target analytes prior to shipping sample containers for sample collection. Field matrix spike recoveries within method acceptance criteria of 10030% confirm that "unknown" components in the sample matrix do not significantly interfere with the extraction and analysis of the analytes of interest. The standards used for the preparation of the field matrix spiking solutions contained reference materials comprised of both linear and branched isomers for PFOA and PFOS. Field matrix spikes are presented in section 4 of this report. FMS Recovery - (Sample Concentration of FMS - Average Concentration: Field Sample & Field Sample Dup.) * 1 0 0 % Spike Concentraton Table 9. Field Matrix Spike Concentrations. Location ACI ACM2 ACE WW8R, WW9R, WW10R, WW11R Trip Blank Description Field Matrix Spike Field Matrix Spike Field Matrix Spike Field Matrix Spike Low Field Matrix Spike High Field Matrix Spike Firial Concentr.tion (ng/mL PFOA PFBS PFHS PFOS 1984 4.96 4.96 2000 5.00 5.00 2004 5.00 5.00 1996 4.99 4.99 2480 4.96 2480 2500 5.00 2500 2505 5.00 2505 2495 4.99 2495 PAGE 12 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 4 Data Summary and Discussion The tables below summarize the sample results and field matrix spike recoveries for the seven locations as well as the Trip Blank. Each table provides the average concentration and the relative percent difference (%RPD) of the sample and sample duplicate. Results and average values are rounded to three significant figures. Relative percent difference (%RPD) values are rounded to two significant figures. Because of rounding, values may vary slightly from those listed in the raw data. Field matrix spikes meeting the method acceptance criteria of 30%, demonstrate that the method is appropriate for the given matrix. All field matrix spike samples and surrogate recovery standards met method acceptance criteria except where noted below. DAL-GW-ACM2; the FMS sample (5 ng/mL) was not appropriate for PFBS; however, the surrogate recovery standard 13C4-PFOS met method acceptance criteria. No additional QC samples were prepared. PAGE 13 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 10. DAL GW ACI 140130 (1) 3M LIMS ID Sample Description ISO14-07-01-001 DAL-GW-ACI-0-140130 ISO14-07-01-002 DAL-GW-ACI-DB-140130 ISO14-07-01-003 DAL-GW-ACI-FMS-140130 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 1550 NA 1610 NA 3000 71.6 1580 ng/mL 3.8% Concentration (ng/mL) %Recovery 192 NA 211 NA 2310 105 202 ng/mL 9.4% 3M LIMS ID Sample Description ISO14-07-01-001 DAL-GW-ACI-0-140130 ISO14-07-01-002 DAL-GW-ACI-DB-140130 ISO14-07-01-003 DAL-GW-ACI-FMS-140130 Average Concentration (ng/mL) %RPD PFHS PFOS Concentration (ng/mL) %Recovery 861 NA 829 NA 2910 103 845 ng/mL 3.8% Concentration (ng/mL) %Recovery 2670 NA 2720 NA 4890 110 2700 ng/mL 1.9% 13C4-PFOA 13C4-PFOS 3M LIMS ID Sample Description ISO14-07-01-001 DAL-GW-ACI-0-140130 ISO14-07-01-002 DAL-GW-ACI-DB-140130 ISO14-07-01-003 DAL-GW-ACI-FMS-140130 Average Concentration (ng/mL) %RSD %Recovery 98.5 98.4 90.6 95.8% 4.7% %Recovery 110 110 101 107% 4.6% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 14 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 11. DAL GW ACM2 140130 3M LIMS ID Sample Description ISO14-07-01-004 DAL-GW-ACM2-0-140130 ISO14-07-01-005 DAL-GW-ACM2-DB-140130 ISO14-07-01-006 DAL-GW-ACM2-FMS-140130 Average Concentration (ng/mL) %RPD 3M LIMS ID Sample Description ISO14-07-01-004 DAL-GW-ACM2-0-140130 ISO14-07-01-005 DAL-GW-ACM2-DB-140130 ISO14-07-01-006 DAL-GW-ACM2-FMS-140130 Average Concentration (ng/mL) %RPD PFOA (1) PFBS (2) Concentration (ng/mL) %Recovery 0.336 NA 0.320 NA 5.17 97.6 0.328 ng/mL 4.9% Concentration (ng/mL) %Recovery 2710 NA 2620 NA 2750 NC 2670 ng/mL 3.4% PFHS (1) PFOS (1) Concentration (ng/mL) %Recovery 0.253 NA 0.212 NA 4.92 93.8 0.233 ng/mL 18% Concentration (ng/mL) %Recovery 1.99 NA 1.84 NA 6.73 96.5 1.92 ng/mL 7.8% 13C4-PFOA (1) 13C4-PFOS (1) 13C4-PFOS (2) 3M LIMS ID Sample Description ISO14-07-01-004 DAL-GW-ACM2-0-140130 ISO14-07-01-005 DAL-GW-ACM2-DB-140130 ISO14-07-01-006 DAL-GW-ACM2-FMS-140130 Average Concentration (ng/mL) %RSD %Recovery 79.2 84.1 100 87.8% 12% %Recovery 97.3 97.4 99.1 97.9% 1.0% %Recovery 112 108 116 112% 3.7% NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration. (1) Samples were analyzed by internal standard calibration. (2) Samples were analyzed by external standard calibration. The surrogate recovery standard 13C4-PFOS was added to the samples during sample preparation. PAGE 15 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 12. DAL GW ACE 140130 (1) 3M LIMS ID Sample Description ISO14-07-01-007 DAL-GW-ACE-0-140130 ISO14-07-01-008 DAL-GW-ACE-DB-140130 ISO14-07-01-009 DAL-GW-ACE-FMS-140130 Average Concentration (ng/mL) %RPD 3M LIMS ID Sample Description ISO14-07-01-007 DAL-GW-ACE-0-140130 ISO14-07-01-008 DAL-GW-ACE-DB-140130 ISO14-07-01-009 DAL-GW-ACE-FMS-140130 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 0.495 NA 0.485 NA 5.22 95.4 0.490 ng/mL 2.0% Concentration (ng/mL) %Recovery 0.238 NA 0.276 NA 5.05 95.9 0.257 ng/mL 15% PFHS PFOS Concentration (ng/mL) %Recovery 0.230 NA 0.207 NA 5.32 102 0.219 ng/mL 11% Concentration (ng/mL) %Recovery 0.210 NA 0.208 NA 5.36 103 0.209 ng/mL 0.96% 13C4-PFOA 13C4-PFOS 3M LIMS ID Sample Description ISO14-07-01-007 DAL-GW-ACE-0-140130 ISO14-07-01-008 DAL-GW-ACE-DB-140130 ISO14-07-01-009 DAL-GW-ACE-FMS-140130 Average Concentration (ng/mL) %RSD %Recovery 94.5 80.9 86.3 87.2% 7.9% %Recovery 79.8 80.6 99.8 86.7% 13% NA = Not Applicable (1) Samples were analyzed by internal standard calibration. PAGE 16 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 13. DAL GW WW8R 140130 (1) 3M LIMS ID Sample Description ISO14-07-01-010 DAL-GW-WW8R-0-140130 ISO14-07-01-011 DAL-GW-WW8R-DB-140130 ISO14-07-01-012 DAL-GW-WW8R-FMS-140130 Average Concentration (ng/mL) %RPD 3M LIMS ID Sample Description ISO14-07-01-010 DAL-GW-WW8R-0-140130 ISO14-07-01-011 DAL-GW-WW8R-DB-140130 ISO14-07-01-012 DAL-GW-WW8R-FMS-140130 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 2770 NA 2550 NA 5270 105 2660 ng/mL 8.3% Concentration (ng/mL) %Recovery 348 NA 303 NA 3040 109 326 ng/mL 14% PFHS PFOS Concentration (ng/mL) %Recovery 1510 NA 1400 NA 4350 116 1460 ng/mL 7.6% Concentration (ng/mL) %Recovery 4180 NA 3790 NA 7000 121 3990 ng/mL 9.8% 13C4-PFOA 13C4-PFOS 3M LIMS ID Sample Description ISO14-07-01-010 DAL-GW-WW8R-0-140130 ISO14-07-01-011 DAL-GW-WW8R-DB-140130 ISO14-07-01-012 DAL-GW-WW8R-FMS-140130 Average Concentration (ng/mL) %RSD %Recovery 95.3 80.8 84.6 86.9% 8.7% %Recovery 112 102 104 106% 4.8% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 17 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 14. DAL GW WW9R 140130 (1) 3M LIMS ID Sample Description ISO14-07-01-013 DAL-GW-WW9R-0-140130 ISO14-07-01-014 DAL-GW-WW9R-DB-140130 ISO14-07-01-015 DAL-GW-WW9R-FMS-140130 Average Concentration (ng/mL) %RPD 3M LIMS ID Sample Description ISO14-07-01-013 DAL-GW-WW9R-0-140130 ISO14-07-01-014 DAL-GW-WW9R-DB-140130 ISO14-07-01-015 DAL-GW-WW9R-FMS-140130 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 3090 NA 2710 NA 5450 103 2900 ng/mL 13% Concentration (ng/mL) %Recovery 338 NA 295 NA 3000 107 317 ng/mL 14% PFHS PFOS Concentration (ng/mL) %Recovery 1500 NA 1410 NA 4210 110 1460 ng/mL 6.2% Concentration (ng/mL) %Recovery 5050 NA 4540 NA 7580 112 4800 ng/mL 11% 13C4-PFOA 13C4-PFOS 3M LIMS ID Sample Description ISO14-07-01-013 DAL-GW-WW9R-0-140130 ISO14-07-01-014 DAL-GW-WW9R-DB-140130 ISO14-07-01-015 DAL-GW-WW9R-FMS-140130 Average Concentration (ng/mL) %RSD %Recovery 86.6 83.6 86.6 85.6% 2.0% %Recovery 107 102 96.9 102% 4.8% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 18 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 15. DAL GW WW10R 140130 (1) 3M LIMS ID Sample Description ISO14-07-01-016 DAL-GW-WW10R-0-140130 ISO14-07-01-017 DAL-GW-WW10R-DB140130 ISO14-07-01-018 DAL-GW-WW10R-FMS-140130 Average Concentration (ng/mL) %RPD 3M LIMS ID Sample Description ISO14-07-01-016 DAL-GW-WW10R-0-140130 ISO14-07-01-017 DAL-GW-WW10R-DB140130 ISO14-07-01-018 DAL-GW-WW10R-FMS-140130 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 1310 NA 1340 NA 3940 105 1330 ng/mL 2.3% Concentration (ng/mL) %Recovery 226 NA 274 NA 3030 111 250 ng/mL 19% PFHS PFOS Concentration (ng/mL) %Recovery 752 NA 762 NA 3610 114 757 ng/mL 1.3% Concentration (ng/mL) %Recovery 1530 NA 1600 NA 4160 104 1570 ng/mL 4.5% 13C4-PFOA 13C4-PFOS 3M LIMS ID Sample Description ISO14-07-01-016 DAL-GW-WW10R-0-140130 ISO14-07-01-017 DAL-GW-WW10R-DB140130 ISO14-07-01-018 DAL-GW-WW10R-FMS-140130 Average Concentration (ng/mL) %RSD %Recovery 94.1 99.0 88.3 93.8% 5.7% %Recovery 108 107 107 107% 0.56% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 19 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 16. DAL GW WW11R 140130 (1) 3M LIMS ID Sample Description ISO14-07-01-019 DAL-GW-WW11R-0-140130 ISO14-07-01-020 DAL-GW-WW11R-DB-140130 ISO14-07-01-021 DAL-GW-WW11R-FMS-140130 Average Concentration (ng/mL) %RPD 3M LIMS ID Sample Description ISO14-07-01-019 DAL-GW-WW11 R-0-140130 ISO14-07-01-020 DAL-GW-WW11R-DB-140130 ISO14-07-01-021 DAL-GW-WW11R-FMS-140130 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 827 NA 801 NA 3240 97.8 814 ng/mL 3.2% Concentration (ng/mL) %Recovery 170 NA 165 NA 2850 107 168 ng/mL 3.0% PFHS PFOS Concentration (ng/mL) %Recovery 362 NA 361 NA 3020 106 362 ng/mL 0.28% Concentration (ng/mL) %Recovery 1570 NA 1500 NA 4120 104 1540 ng/mL 4.6% 13C4-PFOA 13C4-PFOS 3M LIMS ID Sample Description ISO14-07-01-019 DAL-GW-WW11 R-0-140130 ISO14-07-01-020 DAL-GW-WW11R-DB-140130 ISO14-07-01-021 DAL-GW-WW11R-FMS-140130 Average Concentration (ng/mL) %RSD %Recovery 94.4 88.9 80.4 87.9% 8.0% %Recovery 116 103 92.6 104% 11% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 20 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Table 17. Trip Blank Results 3M LIMS ID ISO14-07-01-022 ISO14-07-01-023 ISO14-07-01-024 Sample Description DAL-GW-TRI P-0-140130 DAL-GW-TRIP-LS-140130 DAL-GW-TRI P-HS-140130 3M LIMS ID ISO14-07-01-022 ISO14-07-01-023 ISO14-07-01-024 Sample Description DAL-GW-TRI P-0-140130 DAL-GW-TRI P-LS-140130 DAL-GW-TRI P-HS-140130 PFOA PFBS Concentration (ng/mL) <0.0240 (1) 4.50 (1) 2310 (2) %Recovery NA 90.7 93.1 Concentration (ng/mL) <0.0250 (1) 5.83 (1) 2470 (2) %Recovery NA 117 98.8 PFHS PFOS Concentration (ng/mL) <0.0250 (1) 4.61 (1) 2550 (2) %Recovery NA 92.2 102 Concentration (ng/mL) <0.0232 (1) 4.73 (1) 2550 (2) %Recovery NA 94.8 102 13C4-PFOA 13C4-PFOS 3M LIMS ID ISO14-07-01-022 ISO14-07-01-023 ISO14-07-01-024 Sample Description DAL-GW-TRI P-0-140130 DAL-GW-TRI P-LS-140130 DAL-GW-TRI P-HS-140130 %Recovery 84.6 (1) 91.7 (1) 84.8 (2) %Recovery 108 (1) 91.2 (1) 97.8 (2) NA = Not Applicable (1) Samples were analyzed by internal standard calibration. (2) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 21 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 5 Conclusion Laboratory control spikes were used to determine the analytical method accuracy and precision for all analytes. The accuracy and precision were then used to estimate the method uncertainty for the results. Field matrix spike recoveries demonstrated that the analytical method was appropriate for the given sample matrix. Analysis was completed using 3M Environmental Laboratory Method ETS-8044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Analytical results are reported in Table 1 and 10-17 of this report. 6 Data / Sample Retention All remaining sample and associated project data (hardcopy and electronic) will be archived according to 3M Environmental Laboratory standard operating procedures. 7 Attachments Attachment A: Analyte Trend Data for the Decatur Ground Water Treatment Plant (GWTP) GAC System. 8 Signatures Digitally signed by Susan T. Wolf DN: c=US, st=MN, l=St. Paul, ou=3M Environmental Laboratory - authenticated by LRA, email=stwolf@mmm.com, o=3M, cn=Susan T. Wolf Reason: I have reviewed this document Date: 2014.02.28 10:58:06 ~06'00' Susan T. Wolf, 3M Principal Analytical Investigator Digitally signed by William K. Reagen DN: c=US, st=MN, l=St. Paul, ou=Laboratory Director, ou=3M Environmental Laboratoryauthenticated by LRA, email=wkreagen@mmm.com, o=3M, cn=William K. Reagen Reason: I am approving this document Date: 2014.02.28 15:33:28 -06*00* William K. Reagen, Ph.D., 3M Environmental Laboratory Technical Director The 3M Environmental Laboratory's Quality Assurance Unit has audited the data and report for this project. Digitally signed by Daryl K. Peterson DN: c=US, st=MN, l=St. Paul, ou=3M Environmental Laboratory - authenticated by LRA, email=dpeterson2@mmm.com, o=3M, cn=Daryl K. Peterson Reason: I am approving this document Date: 2014.03.03 07:52:31 ~06'00' Quality Assurance Representative This test report shall not be reproduced except in full, without written approval o f the 3M Environmental Laboratory. PAGE 22 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System ACI (Activated Carbon Influent) - Sample Results in ng/mL ACI PFOA PFBS PFHS PFOS 2/13/13 2300 830 1580 2940 3/27/13 2220 1060 1090 2490 4/29/13 1480 1360 777 1670 5/31/13 1860 1040 940 2150 6/27/13 1480 708 942 1590 7/23/13 1630 1230 749 1680 9/30/13 2320 356 1400 3240 10/28/13 1880 1590 866 2100 11/18/13 2190 1100 1330 2240 12/13/13 1830 1350 695 1970 1/30/14 1580 202 845 2700 ACE (Activated Carbon Effluent) - Sample Results in ng/mL ACE PFOA PFBS PFHS PFOS 2/13/13 0.124 0.0360 0.178 0.0329 3/27/13 0.0380 <0.0250 0.0477 <0.0232 4/29/13 0.0422 0.392 0.0570 <0.0232 5/31/13 0.0725 24.8 0.105 <0.0232 6/27/13 0.0717 111 0.118 <0.0232 7/23/13 0.0641 1960 0.0778 0.0277 9/30/13 0.115 1950 0.156 0.0452 10/28/13 0.231 0.379 0.180 0.0785 11/18/13 0.478 0.592 0.366 0.0726 12/13/13 0.0798 0.0766 0.0648 0.0303 1/30/14 0.490 0.257 0.219 0.209 PAGE 23 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System WW8R - Sample Results in ng/mL W W 8R PFOA PFBS PFHS PFOS 2/13/13 3250 354 1900 4850 3/27/13 3640 385 1760 5120 4/29/13 3190 364 1610 4830 5/31/13 2760 289 1330 4180 WW9R - Sample Results in ng/mL 6/27/13 2760 282 1340 4110 7/23/13 2640 263 1260 3910 9/30/13 2890 303 1370 4100 10/28/13 2830 312 1300 4410 11/18/13 3040 362 1440 4750 12/13/13 2720 316 1270 4060 1/30/14 2660 326 1460 3990 W W 9R PFOA PFBS PFHS PFOS 2/13/13 2850 236 1400 4100 3/27/13 3330 278 1440 4660 4/29/13 2650 244 1200 4340 5/31/13 2660 226 1120 4210 6/27/13 2630 225 1140 4150 7/23/13 2410 212 1030 3670 9/30/13 2730 249 1220 4200 10/28/13 2820 286 1280 4380 11/18/13 2950 305 1340 4540 12/13/13 2690 259 1170 4190 1/30/14 2900 317 1460 4800 PAGE 24 OF 25 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-01 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System WW10R - Sample Results in ng/mL W W 10R PFOA PFBS PFHS PFOS 9/30/2013 2070 247 1030 2770 10/28/2013 2150 264 1030 3160 11/18/2013 2400 303 1120 3890 12/13/2013 1890 239 885 2920 1/30/2014 1330 250 757 1570 WW11R - Sample Results in ng/mL W W 11R PFOA PFBS PFHS PFOS 9/30/2014 1720 299 1000 2200 10/28/2014 1100 240 511 1670 11/18/2014 1320 287 680 1850 12/13/2013 1060 198 512 1570 1/30/2014 814 168 362 1540 PAGE 25 OF 25