Document re0kdMVQNrj34EZm1wb3jKr
(Ur.
Beli Laboratories
600 Mountain Avenue Murray Hill, New Jersey 07974 Phone (201)582-3000
February 27, 1979
G. Perrine New York Telephone Company
1095 Avenue of the Americas New York, New York 10036
Dear George:
The five filter cassettes you sent which were used for sampling at 1695 Broadway, New York have been analyzed for asbestos. All fibers greater than 5 um long seen by phase
contrast optical microscopy at 400x were counted using the methods recommended by the National Institute of
Occupational Safety and Health (NI0SH). Based on the optical microscopy results and your sampling data the results were:
Sample 1 PBX Ironwork 2 Horiz X-conn Block 3 Roof 4 701 PBX 17 hrs.
Blank
Volume Air CL)
___ ** - - **
120 2040
Fibers Counted*
2
4 1 17 3
Fibers/cm -- --
.01 .01 --
* 72 . 100 microscope fields C.011 mm /field) were counted. The filter area was 855 mm^.
Samples #1 and #2 were dust samples.
If you have any questions about this analysis please give me a call.
Sincerely,
Q/P
Charles P. Lichtenwalner
Copy to See next page
CONFIDENTIAL
003807
Copy to P. H. Stark - NYT C. H. Steinmetz, M.D.
W. J. Schreibeis G. M. Wilkening
R. L. Beach : ATT^
N. J. DeCapua J. M. Degen R. W. Stone, M.D.
2
CONFIDENTIAL
00?80S