Document rb8rgd9N81jzv9nV5a278jL0
Monsanto
5rr,c
FROM
,(NAME --LOCATION. phone J# Hj Qrem _ Galt Labs - 1730
_________________________________________________
DATE SUBJECT REFERENCE
June 21, 1978
POLYSULFIDE SEALANTS FOR INSULATED WINDOW GLASS
cc- N. W. Touchette Polysulfide Sealant File
TO
A. W. Morgan
The AAMA (Architectural Aluminum Manufacturers Association) fogging test uses 6"X6" sheets of cured material- These are 60 mils thick. The sheet is folded and slipped into a beaker. The beaker is covered with a glass plate. A condenser, through which tap water is circulated, is placed on top of the glass plate. The beaker is heated in a glycerine bath. This test determines the temperature at which fog occurs. For new formula tions, they will start at 90F for 24 hours; the temperature is raised in 10F increments (always 24 hours duration) until fog is observed.
If we need to study fogging, our oil immersion procedure will suffice. We would have to elevate the temperature or increase the time because we do not have the condenser. I described this to Norton and PRC, and they believed it would be a satisfactory procedure.
JHO/gls
; J\.w.^Orem
O
DSW 588385
STLCOPCB4093721