Division Headquarters December 28, 1961 FDA # 54
PLAINTIFFS - EXHIBITS^
JMMC-244
TO: 322-S, 321-S, 12, 1071
PERSPECTIVE
It is salutary we feel, to step back from the heat and action of the day's battle and view your adversary long range. Often it is revealing because points of vulnerability sometimes stand out quite clearly.
The service record of cast iron pipe in the past and the promise of future service
life can be "appreciated" in practical perspective when one reviews a simple
chronological listing of Time vs. Events that illustrate the evolution of cast
iron pipe. Notice the trend in wall thickness.
CLASS 150
TIME
EVENT
WALL THICKNESS 6" 12"
Circa I664
Versailles, France In-
|
stallation.
1
2L"
" 1803
First cast iron laid in U.S. in Philadelphia.
" 1850 " 1881
1908 1924
Vertical pit casting start ed in U. S.
American Water Works Association formed.
First AWWA Specification covering Pit Cast Pipe
Centrifugal casting started in U.S. on production basis
PIPE O.D.
F/PST STANDAPD ON WALL
thickness
j P/PE ID.
I
I
J > 0.51"
.68" 1.04"
1927
Federal Specification covering centrifugal cast pipe (WW-P-421)
.37 .50 .76
1952
ASA Specifications covering centrifugal cast pipe
.38 .48 .73
1955
Federal Specification (WW-P-421a) changed to agree with ASA
1957 Present
Cast Iron pushing higher strength metal (21/45)
Rumor about Ductile Iron
.35 .41 68
r
1
CONFIDENTIAL
-2
December 28, 1961
Corrosion of Cast Iron of Various Compositions
"The many experiments on a laboratory scale, using agitated water as the corroding agency resulted in the conclusion that all cast iron of com positions usable practically in cast iron pipe for water and gas--that is, capable of being cut, drilled and tapped--corroded at substantially the same rate, so that the problem of preventing corrosion remained one of protection rather than composition of iron."
(Quotation from ASA - A21.1 - 1957 "Manual for Computation of Strength and Thickness of Cast Iron Pipe").
Observations
1. Standardized wall thicknesses have been in use for only the past 54 years. Wall thicknesses of pipe before 1908 may have been much thicker.
2. Cast Iron Specifications have permitted a 25 to 30 per cent reduction in wall thickness (depending on size) from pit cast to present ASA thicknesses.
3. Cast Iron pipe as supplied today (centrifugal casting) enjoys an actual service record of 38 years (since 1924) in the U, S. and not 100 years plus as suggest ed in advertising, (note Transite dates from 1930).
4. In view of the comment on corrosion, it is doubtful that today's cast iron pipe will provide a similar long service record (on the average) as pipe of the 1800's has provided.
Place this in TR 200-A under Competition.
OAW/bgs
0. A. WIRSIG