Document rVd4e2rJE3ZVqexrQ34D2O6V

BESTWALL GYPSUM CCMPANY DIRECTION INDEX Bestwall Fibered or Extra Fibered Best-wall Unfibered - Brown or White Bestwall Fibered Lite-Mix Bestwall Unfibered Lite-Mix Bestwall Lite-Mix Masonry Mix Bostwa!! Gauging - Slow Set Bestwall Gauging - Guich Set Bestwall Wood Fibered (100'^ Bog) Bestwall Wood Fibered (iO^1 Bag) Bestwall Metro Mix Bestwall Satin-Spar White Gauging - Guide Set Bestwall Su'.in-Spa.- Whit;. Gauging - Slow Set Bestwall Powdered Certsx i tsufral Texture Bestwall Joint System Bestwall Bedding 2 Tep^itig Compound Bestwall Spudding Compound Bestwall Patching Plaster Bestwall Retarder Bestwall Builders Lime Bestwall Masons Linr.e Bestwall Smooth Finish Lime Bestwall Speedy Masons Lima Bestwall Trowel Finish Bestwall Grabit Bestwall Joint System Compound Bestwall Joint System All Purpose Compound Bestwall Concrete Bond Bestwall Gauging - Medium Set Bestwall Laminating Compound Bestwall Glass Fibered - Machine Application Bestwall Unfibered - Machine Application Bestwall Light Acoustical Plaster - Gun Application Bestwall Powdered Bestex White Texture Bestwall Powdered Bestex White Texture - Spray Application Bestwall Fibered Twin Plaster Bestwall Unfibered Twin Plaster Bestwall Five Star Joint System Bestwall 1 ">ay Joint Compound Bestwall All Purpose Joint Compound (With Tape) Bestwall Dens-Cote Smooth Finish Page No. D-l D-2 D-3 D-4 D-5 D-6 D-7 D-8 D-9 D-10 D-ll D-12 D-13 D-l 4 D-15 D-16 D-17 D-l 8 D-19 D-20 D--21 D-22 D--23 D-24 D-25 D-26 D-27 D-20 D-29 D-30 D-31 D-32 D-33 D-34 D-35 D-36 D-37 D-33 D-39 C-40 (Revised 8/13/63) SGP 0003687 Direction j'/D-l DIRECTIONS FOR BESTWALL FIBERED OR EXTRA FIBFRED PIASTER *______________ Fibered Plaster is for interior basecoat plastering on the following type plaster bases: gypsum lath, metal and wire lath, masonry except monolothic concrete and wood lath. * Fibered Plaster meets A.S.T.M. Specification C-28-55 and Federal Specification SS-P02 Type N. Sand or lightweight aggregate (perlite or vermiculite) to be used with _______ Fibered Piaster as bssecoat plastering shall conform to A.S.T.M. Specification C-35-54T. PROPORTIONING OF AGGREGATES PEE 100 LBS. PLASTER SIIALL NOT EXCEED TEE FOLLOWING: Perlite or Vermiculite Sand (6 jf-2 Shovels Equal 1 cu. ft.) Over Gypsum Loth Two Coat Work Three Goat Work Scratch Coat Brown Coat cu. ft. cu. ft. cu. ft. 2^ cu. ft 2 cu. ft. 3 cu. ft. Over Metal Lath or Wood Lath Three Coat Work Scratch Coat Brown Coat cu. ft. cu. ft. 2 cu.- ft. 3 cu. ft. Over Masonry except Monolithic Concrete Two or Three Coat Work cu. ft. 4 cu. ft. NOTE BAG MANUFACTURER: These blanks are to be filled in with "Bestwall" or "Bestwall Extra", whichever is appropriate for the bag ordered. (Revised 3/30/63) Page ?, D-1 SGP 0003688 Direction #D-1 (Continued) MIXING Keep tools and equipment clean. Use clean vater only. For hand mixing. Dry blend the plaster and aggregate in the mortar box, then add water and blend thoroughly with the hoe. Do not mix damp sand with plaster and let stand in the box before adding water. Clean the box after each batch. For machine mixing. With the agitator running, add the approximate amount of via ter needed, half the aggregate, all of the plaster, and then the remainder of the aggregate, and mix thoroughly to proper consistency, adding additional water if necessary. Dump the batch when completely mixed and, if another batch is not to be mixed right away, clean out the mixer ready for next batch . APPLICATION For two coat work. Base or first coat shall be applied with suffi cient pressure and material to form good bond on gypsum lath or masonry a6 the case mny be, end to cover well. Then, before this scratch coat has set and without raking its surface, material of same proportions shall be doubled back to bring out to grounds and struck to a true surface with rod and darby without application of water and cross rake or scratch to provide a mechanicnl key for reception of the finish (second coat). For three coat work. Scratch or first coat shall be applied to cover well (minimum of 3/l6" over face of metal lath) and with sufficient pressure and material to form good full keys on wood end metal lath, wire lath and wire frbric, and good bond on gypsum lath or masonry. Then it should be scratched to a rough surface. Page vv'D-lA SGP 0003689 Direction f/D-1 (Continued) The brown or second coot shell be applied after the scratch coat has set firm and hard, brought out to grounds, straightened to a true surface with rod and darby without application of water and cross rake or scratch to provide a mechanical key for reception of the finish (third coat). NOTE: Three coat work shall always be used over metal lath, wood lath, or other resilient lath. Gypsum sand float finish. Gypsum sand float finish shall be mixed in proportion of not more than 2 parts of sand by weight to 1 part of unfibered plaster. Where flbered plaster is used, the fiber should be screened from the plaster. The plaster shall be scratched in tight over the basecoat, brought out to an even surface with the trowel, and then floated to a true surface free from slick spots or other blemishes. PRECAUTIONS before plastering over porous absorptive masonry, wet the surface to reduce suction and prevent shrinkage cracks. Several hours before plastering over wood lath, the lath should be wet thoroughly to prevent plaster cracking. Do not retemper. Screen openings in hot weather to prevent dryouts. Provide adequate heat in cold weather to prevent freezing. When plaster has set hard and firm, provide ventilation for adequate drying. (SIGNATURE) * ** STORE IN DRY PLACE FROTFCT PIASTER FROM MOISTURE AT ALL TIMES Page f^D-lB SGP 0003690 Direction jrD-2 DIRECTIONS FOR BESTWALL UNFIBERED PLASTER Bestwall Unfibered Plaster is for interior base coat plastering on the following plaster bases: gypsum lath and masonry except monolithic concrete. It is also suitable for interior gypsum sand float finish. Bestwall Unfibered Plaster meets A.S.T.M. Specification No. C-28-55 and Federal Specification SS-P-402 Type N. Sand or lightweight aggregate (perlite or vermiculite) to be used with Bestwall Unfibered Plaster as basecoat plastering shall conform to A.S.T.M. Specification C-35-54T. NOTE: When to be UBod in gypBum eand float finish, the Band shall pass a No. 12, 16, or 20 mesh 3ieve, depending on the texture of the surface desired. PROPORTIONING OF AGGREGATES PER 100 LBS. PLASTER SHALL NOT EXCEED THE FOLLOWING: Perlite or Vermiculite Sand (6 #2 Shovels Equal 1 cu. ft. ) Over Gypsum Lath Two Coat Work Three Coat Work Scratch Coat Brown Coat 2 cu. ft. 2 cu. ft. 2 cu. ft. 2^ cu. ft 2 cu . ft. 3 cu. ft. Over Metal Lath or Wood Lath Three Coat Work Brown Coat 2 cu. ft. 3 cu. ft. Ovar Masonry except Monolithic Concrete Two or Three Coat Work 3 cu, ft. 4 cu. ft. (Revised 3/30/63) Page #D-2 SGP 0003691 Direction #D-2 (Continued) MIXING Keep tools and equipment clean. Use clean water only. For hang mixing. Dry blond the plaster and aggregate in the mortar box, then add water and blend thoroughly with the hoe. Do not mix damp sand with plaster and let stsnd in the box before adding water. Clean the box after each batch. For machine mixing. VJith the agitator running, add the approximate amount of water needed, half the aggregate, all of the plaster, and then the remainder of the aggregate, and mix thoroughly to proper consistency, adding additional vater if necessary. Dump the batch when completely mixed and, if another batch is not to be mixed right away, clean out the mixer ready for next batch. APPLICATION For two coat work. Base or first coat shall be applied with suffi cient pressure end material to form good bond on gypsum lath or masonry as the case may be, and to cover well. Then before this scratch coat has set and without raking its Burface, material of same proportions shall be doubled back to bring out to grounds and struck to a true surface with rod and darby without application of water and croBS rake or scratch to provide a mechanical key for reception of the finish (second coat). For three coat work. Scratch or first coat shall be applied to cover well (minimum of 3/l6" over face of metal lath) and with sufficient pressure and material to form good bond on gypsum lath and masonry. Then it should be scratched to a rough surface. Page jfD-2A SGP 0003692 Direction itD-2 (Continued) The brown or second cost shall be applied after the Bcratch coat has set finn and hard, brought out to grounds, straightened to a true surface with rod and darby without application of water and cross rake or scratch to provide a mechanical key for reception of the finish (third coat). NOTE: Three coat work shall always be used over resilient lath. Gypsum sand float finish. Gypsum sand float finish shall be mixed in proportion of not more than 2 parts of sand by weight to 1 part of unfibered plaster. The plaster shall be scratched in tight over the basecont, bvouphi out to an even surface with the trowel, and then floated to a true surface free from slick spots or other blemishes. PRECAUTIONS Before plastering over porous absorptive masonry, wet the surface to reduce suction and prevent shrinkage cracks. Several hours before plastering over wood lath, the lath should be wet thoroughly to prevent plaster cracking. Do not retemper. Screen openings in hot weather to prevent dryouts. Provide adequate hont in cold weather to prevent freezing. When plaster has set hard and firm, provide ventilation for adequate drying. (SIGNATURE) *** STIRE IN DRY PLACE PROTECT PIASTER FROM MOISTURE AT ALL TIMES Page j;D-2B SGP 0003693 Direction //D-3 DIRECTIONS FOR BESTWALI, LITE-MIX FIBEKED PIASTER Bestwall Lite-Mix Fibered Plaster is ready-mixed plaster with perlite aggregate for interior baBecont plastering on the following type plaster bases: gypsum lath, metsl and wire lath, fiber insulation lath and wood lath. It meets A.S.T.M. Specification C-28-55 for Gypsum Ready-Mixed Plaster. MIXING For hand mixing. Place Bestwall Lite-Mix plaster in one end of mortar box, add water in the other end and hoe the plaster into the water. Mix thoroughly to pioper consistency. Clean the box after each batch. For mnchine mixing . Add the required amount of water to the mixer and with the agitator running add the plaster. Mix thoroughly to proper consistency, adding ino^e water if necessary. Dump the batch immediately after it is comilotely mixed. If another batch is not to be mixed right away, wash out the mixer and leave clean for next batch. APPLICATION For two coa t work on gypsum lath . Base or first coat shall be applied with sufficient pressure and material to form good bond and to cover well. Then before this scratch coat has set and without raking its surface, 6ame plaster shall be doubled back to bring out to grounds, struck to a true surface with rod and darby and left rough for reception of finish (second (second) coat. For three coat work on gypsum leth, metal and wire lath, fiber insula tion lath and wood lath. Scratch or first coat shall be applied to cover well end with sufficient pressure and material to form good full keys on Page ?,D-3 SGP 0003694 Direction $D-3 (Continued) wood end metal loth, wire l^tli and wire fabric, and good bond on gypsum loth end fiber insulation lath. Then it should be scratched to a rough surface. The brown or Becond coat shall be applied after the Bcratch coat has set firm and hard, brought out to grounds, straightened to a true surface with rod and darby and left rough, ready to receive the third or finish coat. NOTE: Three coat work shall always be used over fiber insulation lath, wood lath, metal lath or any other resilient lath. PRECAUTIONS Lite-Mix plaster is not intended for use over masonry bases. For plastering over masonry, use Masonry Lite-Mix. Several hours before plastering over wood lath, the lath should be wet thoroughly to prevent shrinkage cracking. Do not retemper. Screen openings in hot weather to prevent dryouts. Provide adequate heat in cold weather to prevent freezing. When plaster has set hard and firm, provide ventilation for adequate drying. Add water only, plaster has proper amount of aggregate. (SIGNATURE) *** STORE IN DRY PLACE PROTECT PLASTER FROM MOISTURE AT ALL TIMES Page vfD-3A SGP 0003695 Direction ^D-h DIRECTIONS FOR BE3TVJA LL LITE-MIX UNFIEERED PIASTER Bestwsll Lite-Mix Unfibered Plaster is a ready-mixed plaster with perlite aggregate for Interior basecoat plastering on the following type plaster bases: gypsum lath and fiber insulation lath; and for brown coat plastering on metal and wire lath, fiber insulation lath and wood lath. It meets A.S.T.M. Specification C-28-55 for Gypsum Ready-Mixed Plaster. MIXING For hand mixing. Place Bestwall Lite-Mix Plaster in one end of mortar box, add water in the other end and hoe the plaster into the water. Mix thu'oughl.y to proper consistency. Clean the box after each batch. For machine mixing. Add the required amount of water to the mixer and with the agitator running add the plaster. Mix thoroughly to proper consistency, adding more water-if necessary. Dump the batch immediately after it is completely mixed. If another batch is not to be mixed right away, wash out the mixer and leave clean for next batch. APPLICATION For two coat work on gypsum lath. Base or first coat shall be applied with sufficient pressure and material to form good bond and to cover well. Then before this scratch coat has set and without raking itB surface, 6ame plaster shall be doubled back to bring out to grounds and struck to a true surface with rod and darby and left rough for reception of finish (second) coat. For three coat work on fiber insulation lath. Scratch or first coat shall be applied to cover well and with sufficient pressure and material to form good bond to the lath. Then it should be scratched to Page fD-4 SGP 0003696 Direction #D-k (Continued) a rough surface. The brown oi* second coat 6hall be applied after the scratch coat has set firm and hard, brought out to grounds, straightened to a true surface with rod and darby and left rough, ready to receive the third or finish coat. For brown coat in three coat work over gypsum lath, metal and wire lath, fiber Insulation lath and wood lath. After the scratch coat has set firm and hard, Bestwall Lite-Mix Unfibercd Plaster may be used as the second or brown coat. It is applied over the scratch coat, brought out to grounds, straightened to a true surface with rod and darby and left rough, ready to receive the third or finish coat. NOTE: Three coat work shell always be uced over fiber insulation lath, wood lath, metal lath or any other resilient lath. PRECAUTIONS Lite-Mix plaster is not intended for use over masonry bases. For plastering over masonry, use Masonry Lite-Mix. Do not retemper. Screen openings in hot westher to prevent dryouts. Provide adequate heat in cold westher to prevent freezing. When plaster has set hard and firm, provide ventilation for adequate drying. Add water only, plaster has proper amount of aggregate. (SIGNATURE) *** STORE IN DRY PLACE PROTECT PLASTER FROM MOISTURE AT ALL TIMES Page >(`D-4A SGP 0003697 Direction #D-5 DIRECTIONS FOE BESTWALL LITE-MIX MASONRY MIX PLASTER Bestwall Lite-Mix Masonry Mix Plaster is a ready-mixed plaster with perlite aggregate for interior basecoat plastering over all types of masonry except monolithic concrete. It meets A.S.T.M. Specification C-28-55 for Gypsum Ready-Mixed Plaster. MIXING For hand mixing. Place Bestwall Lite-Mix Masonry Mix Plaster in one end of mortar box, add water in the other end and hoe the plaster into the water. Mix thoroughly to proper consistency. Clean the box after each batch. For machine mixing. Add the required amount of water to the mixer and with the agitator running add the piaster. Mix thoroughly to proper consistency, adding more water if necessary. Dump the batch immediately after it is completely mixed. If another batch is not to be mixed right away, wash out the mixer and leave clean for next batch. APPLICATION For two coat work over masonry except monolithic concrete. Base or first coat shall be applied with sufficient pressure and material to form a good bond with the masonry and to cover well. Then before this first coat has set and without raking its surface, same plaster shall be doubled back to bring out to grounds and struck to a true surface with rod and darby and left rough ready to receive the finish (second) coat. For three coat work over masonry except monolithic concrete. Scratch or first coat shall be applied to cover well and with sufficient pressure Page 7fD-5 SGP 0003698 Direction 7rD-5 (Continued) and material to form e good bond with the masonry. Then it should be scratched to a rough surface. The brown or second coat shall be applied after the scratch coat has set firm and hard, brought out to grounds, straightened to a true surface with rod and darby and left rough, ready to receive the finish coat. PRECAUTIONS Do not retemper. Screen openings in hot weather to prevent dryouts. Provide adequate heat in cold weather to prevent freezing. When piaster has set hard and firm, provide ventilation for adequate drying. Add water only, plaster has proper amount of aggregate. In plastering over some masonry bases which exhibit high suction, it may be necessary to dampen them prior to application of the plaster, in order to reduce the suction somewhat. NOTE: For plastering over monolithic concrete, use only Gypsum Concrete 3ond Plaster. (SIGNATURE) * ** * STORE IN DRY PLACE PROTECT PIASTER FROM MOISTURE AT ALL TIMES Page #D-% SGP 0003699 Direction #D-6 153STUALL GAUGING PLASTH - SLOW SUT DIRECTIONS Bestwall Gauging Plaster meets A.S.T.M. Specification C-28-55 and federal Specification SS-P-402 Type G. Slow Set Gauging is retarded for use. Use with line patty for finish coat in the proportions of one measure of dry gaugmag plaster to not more than three measures of lime putty. Over lightweight aggregate basecoat, add 1/2 to 1 cu. ft. of fine perlite or fine sand per 100 l'os. of gauging plaster. 3use coat must be broomed or roughened. Dampen base coat if necessary to reduce suction. Apply first coat thin as possible, pressing it firmly into base coat; double bac!c with second coat and level out to true even surface. The general thickness of the finish coat shall be l/lb to 1/8 inch. The finish shall be allowed to draw a few minutes and then it shall be well troweled i\fith water to a smooth finish, free from cat faces and other blemishes or irregularities. S TOR Z IU DRY PLACE PROTECT PLASTER FROM MOISTURE AT ALL TIMES (Revised 6/22/64) Page //D-6 SGP 0003700 Direction ^D-7 BESTWALL GAUGING PLASTER - QUICK SET DIRECTIONS Bestwall Gauging Plaster meets A.S.T.M. Specification C-28-55 and Federal Specification SS-P-402 Type G. Quick set gauging is not retarded. Setting time is to be retarded as necessary by the mechanic. Use with lime putty for the finish coat in the proportions of one measure of dry gauging plaster to not more than three measures of lime putty. Over lightweight aggregate basccoat, add 1/2 to 1 cu. ft. of fine per lite or fine sand per 100 lbs. of gauging plaster. Base coat must be broomed or roughened. Dampen base coat if necessary to reduce suction. Apply first coat thin as possible, pressing it firmly into base coat; double back with second coat and level out to true even surface. The general thickness of the finish coat shall be 1/16 to 1/8 inch. The finish shall be allowed to draw a few minutes and then it shall be well troweled with water to a smooth finish, free from cat faces and other blemishes or irregularities. STORE IN DRY PLACE PROTECT PLASTER FROM MOISTURE AT ALL TIMES (Revised 3/30/63) Page ^D-7 SGP 0003701 Direction #D-8 EESTWALL WOOD FIEEKED GYPSUM PIASTER DIRECTIONS Use without sand or not to exceed one part sand to one part plaster by weight. Keep mortar box clean. Mix thoroughly. Do not try to remix after mortar has hardened. When used as patching plaster, remove all loose particles from area to be patched. Thoroughly wet edges of old plaster to reduce suction. Fill 6mell areas flush with old surface and trowel smooth. Fill large areas in two applications. Allow first application to harden, then make second application, filling in flush with old surface and trowel smooth. When dry, touch up patch with fine sand paper if necessary and size before decorating. For large areas and new work, broom or otherwise roughen surface to receive finishing coat. Close or screen all openings until plaster has set. Then ventilate to promote rapid drying. STORE IN DRY PLACE PROTECT PLASTER FROM MOISTURE AT ALL TIMES Page #D-8 SGP 0003702 Direction #D-9 WOOD FIEEKED PIASTER DIRECTIONS Mix to a mortar with water only and UBe immediately. Do not try to remix after mortar has hardened. When used as patching plaster, remove all loose particles from area to be patched. Thoroughly wet edges of old plaster to reduce Buction. Full small areas flush with old surface and trowel smooth. Fill large areas in two applications. Allow first appli cation to harden, then make second application, filling in flush with old surface and trowel smooth. When dry, touch up patch with fine sand paper if necessary and size before decorating. Page #D-9 SGP 0003703 Direction #D-10 METRO-MIX DIRECTIONS This is e gypsum product which requires the addition of water only. Protect the dry Metro-Mix from moisture in storage and transit. Add the dry Metro-Mix to the wster in a deep mixing box or mechanical mixer located for prompt delivery of the slurry to the roof area. Mix thoroughly for not more than two minutes. Do not retemper. Avoid whipping air into the slurry to maintain proper density end strength. Immediately after mixing, pour the mixture on the roof area and screed and level off to specified thickness. Metro-Mix shall not be mixed or poured during weather when the temperature and job exposure will allow the Metro-Mix to freeze before it takes its complete set. Keep all tools and mixing equipment free of set Metro-Mix to maintain uniform Betting time. For Class "A" Metro-Mix, use not more than 8^ gallons clean water per 80 lb. bag. For Class "B" Metro-Mix, use not more than 7 gallons of clean water per 80 lb. bag. STORE IN DRY PLACE PROTECT METRO-MIX FROM MOISTURE AT ALL TIMES Page i(D-10 SGP 0003704 Direction ^D-l 1 BESTWALL SATIN SPAR WHITE GAUGING PLASTER QUICK SET DIRECTIONS Bestwall Satin Spar Gauging Plaster meets A.5.T.M. Specification C-28-55 and Federal Specification SS-P-402 Type G. Quick set gauging is not retarded. Setting time is to be retarded as necessary by the mechanic. Use with lime putty for the finish coat in the proportions of one measure of dry gauging plaster to not more than three measures of lime putty. Over lightweight aggregate basecoat, add 1/2 to 1 cu. ft. of fine per lite or fine sand per 100 lbs. of gauging plaster. Base coat must be broomed or roughened. Dampen base coat if necessary to reduce suction. Apply first coat thin as possible, pressing it firmly into base coat; double back with second coat and level out to true even surface. The general thickness of the finish coat shall be 1/16 to 1/8 inch. The finish shall be allowed to draw a few minutes and then it shall be well troweled with water to a smooth finish, free from cat faces and other blemishes or irregularities. STORE IN DRY PLACE PROTECT PLASTER FROM MOISTURE AT ALL TIMES (Revised 3/30/63) Page ^D-l 1 SGP 0003705 Direction ^D-12 BESTWALL SATIN SPAR WHITE GAUGING PLASTER SLOW'SET DIRECTIONS' Bestwall Satin Spar Gauging Plaster meets A.S.T.M. Specification C-23-55 and Federal Specification 3S-P-402 Type G. Slow set gauging is retarded for use. Use with lime putty for finish coat in the proportions of one measure of dry gauging plaster to not more than three measures of lime putty. Over lightweight aggregate basecoat, add 1/2 to 1 cu. ft. of fine per lite or fine sand per 100 lbs. of gauging plaster. Base coat must be broomed or roughened. Dampen base coat if necessary to reduce suction. Apply first coat thin as possible, pressing it firmly into base coat; double back with second coat and level out to true even surface. The general thickness of the finish coat shall be 1/16 to 1/8 inch. The finish shall be allowed to draw a few minutes and then it shall be well troweled with water to a smooth finish, free from cat faces and other blemishes or irregularities. STORE IN DRY PLACE PROTECT PLASTER FROM MOISTURE AT ALL TIMES (Revised 3/30/63) Page #D-12 SGP 0003706 Direction jfD-13 DIRECTIONS FOR BESTWALL CERTEX TEXTURE PAINT - NEUTRAL *** INSTRUCTIONS FOR MIXING AND APPLICATION FOR USE OVER MOST INTERIOR SURFACES READ CAREFULLY Caution: Use clean water (suitable for drinking) at 60 to 80 Fahrenheit. Be sure mixing equipment is clean. Do not beat air into the mix. Protect work from freezing. Add 25 lbs. of Bestwall Certex to 19 pints of water and mix until the drypowder is completely wetted. Allow the mix to soak for 20 to 30 minutes. After the mix has soaked, add water as necessary to obtain the desired consistency and remix. For heavy textures use about 2b to 25 pints total water and for lighter textures use about 30 to 32 pints total water per 25 lbs. of dry Certex. For application over old surfaces, wash off any water soluble coatings, remove old paint with trisodium phosphate or other strong deter gent and rinse with clean water. Roughen glossy surfaces with sandpaper or steel wool and fill cracks with Bestwall Patching Plaster or Spackling Compound. When such surfaces are dry, apply a vinyl primer or equivalent to even suction over the entire area before texturing. Finish gypsum wallboard surfaces with Bestwall Joint System material. For best results, apply a vinyl primer to the entire area before texturing. Page vD-13 SGP 0003707 Direction #D-13 (Continued) Texturing may be accomplished by using a roller, brush, sponge, or other suitable implement depending on the type of configuration desired. Protect woodwork and trim during application and remove all droppings before they harden. (SIGNATURE) STORE IN DRY PLACE PROTECT TEXTURE FROM MOISTURE AT ALL TIMES Page #D-13A SGP 0003708 Direction #D-l4 DIRECTIONS FOB BESTWALL JOINT SYSTEM *** INSTRUCTIONS FOR MIXING AND APPLICATION READ CAREFULLY Caution: Add water only. Do not mix any other material or ingredient with the dry powder (adhesive) in thiB package. Use clean water (suitable for drinking) at 60 to 80 Fahrenheit. Do not beat air into the mix. Protect work from freezing. Mix 18 lbs. of Bestwall Joint System Compound (an adhesive) with 12-g- pints of water. If dry powder or water or both are cold, more water will be required to reach a workable consistency. Mix at about the consistency the material will be used. The wet mixture will Btiffen during the first 5 to 10 minutes then, after 20 to 30 minutes soaking, will lose its Btiffness. Cold water or cold powder or both may double the required soaking time. After the soaking period has elapsed, the material should be remixed until it becomes plastic and creamy. Add more water to obtain a thinner consistency if desired. Apply Bestwall Joint Compound to all flat joints and shear off surplus, leaving no material on the high edges. Allow to dry for about 2 to 12 hours (depending on drying conditions) before taping. This operation will leave a uniform depth of taper for uniform shrinkage of subsequent applications under and over the tapes. Apply Bestwall Joint System Compound to joints and embed tapes, leaving a uniform thickness of material under the tape. At the same Page #D-l4 SGP 0003709 Direction #D-l4 (Continued) time cover all nailheads with Joint System Compound. Repeat the latter operation with each subsequent application of com pound or as many times as needed. When the Joint System Compound has lightened (anytime after surface dry), cover the taped joint with Joint System Compound. Shear off surplus, leaving a uniform coverage over tapes with edges well feathered. The Joint System Compound under the tapes and the first coat over the tapes must be THOROUGHLY DRY before the next coat over the joints. Cover the Jointb a second time with Joint System Compound and shear off the excess, leaving a smooth well feathered joint. Allow the joints to dry thoroughly before proceeding further. *** For best results cover the joints a third time with Joint System Compound. As an alternate to this step, apply Joint System Compound to the entire area of the board and joints and shear off tight. This operation, called a skim coat, provides the surfaces with a more uniform texture and suction. *** Where a skim coat has been used to finish the wallboard surfaces, a one coat paint application may be acceptable. For best results, a prime coat should be uBed over the entire area before the final decoration. (signature) STORE IN DRY PLACE PROTECT COMPOUND FROM MOISTURE AT ALL TIMES Page fD-lkA SGP 0003710 Direction #D-15 DIRECTIONS FOR BESTWALL JOINT SYSTEM BEDDING COMPOUND DIRECTIONS FOR BESTWALL JOINT SYSTEM TOPPING COMPOUND *** INSTRUCTIONS FOR MIXING AND APPLICATION READ CAREFULLY Caution: Add water only. Do not mix any other material or ingredients with the dry powder (adhesive) In this package. Use clean water (suitable for drinking) at 60 to 80 degrees Fahrenheit. Do not beat air into the mix. Protect work from freezing. BEDDING COMPOUND Mix 25 lbs. of Bestwall Bedding Compound (an adhesive) with 17 pints of W8ter. If water or dry powder or both are cold, more water will be required to reach a workable consistency. Mix at about the consistency the material will be used. The wet mixture will stiffen during the first 5 to 10 minutes then, after 20 to 30 minutes soaking, will lose its stiffness. . Cold water or cold powder or both may double the required soaking time. After the soaking period has elapsed, the material should be remixed until it bfcomes plastic and creamy. Add more water to obtain a thinner consistency if desired. Apply Bestwall Bedding Compound to all flat joints and shear off surplus, leaving no material on the high edges. Allow to dry about 2 to 12 hours (depending on drying conditions) before taping. This operation will leave a uniform depth of taper for uniform shrinkage of subsequent applications under and over the tape. Page #D-15 SGP 0003711 Direction #D-15 (Continued) Apply Bestwall Bedding Compound to joints and embed tapes leaving a uniform' thicknese of material under the tapes. At the same time cover all nailheads with Bedding or Topping Compound. Repeat the latter operation with each subsequent application of Topping Compound or as many times as needed. TOPPING COMPOUND Mix 25 lbs. of Bestwall Topping Compound (an adhesive) with 16 pints of water. If dry powder or water or both are cold, more water will be required to reach a workable conslatency. Mix at about the consistency the material will be used. The wet mixture will stiffen during the first 5 to 10 minutes then, after 20 to 30 minutes soaking, will lose its stiffness. Cold water or cold powder or both may double the required soaking time. After the soaking period has elapsed, the material should be remixed until it becomes plastic and creamy. Add more water to obtain a thinner consistency if desired. When Bedding Compound has whitened (anytime after surface dry), cover the taped jointB with Bestwall Topping Compound. Shear off the surplus, leaving a uniform coverage over tapes with edges well feathered. The Bedding Compound under the tapes and the first coat of Topping Compound must be THOROUGHLY DRY before the next coat over the joints. Cover the joints a second time with Topping Compound and shear off the surplus, leaving a smooth well feathered joint. Allow the Joints to dry thoroughly before proceeding further. *** Page irD-15A SGP 0003712 Direction f^D-l^ (Continued) For best results cover the joints a third time with Topping Compound. As an alternate to this step, apply Bedding or Topping Compound to the entire area of board and joints and shear off tight. This operation, called a skim coat, provides the surface with a more uniform texture and suction. * ** Where a skim coat has been used to finish the wallboard surfaces, a one coat paint application may be acceptable. For best results, a prime coat should be used over the entire area before the final decoration. (SIGNATURE) STORE IN DRY PLACE Page #D-15B SGP 0003713 Direction #D-l6 DIRECTIONS FOR HKSTWALL SPACKLING COMPOUND INSTRUCTIONS FOR MIXING AND APPLICATION MIXING: Use cool water at about 70 F, adding the spackling compound and mixing to a heavy putty, free of lumps. Generally the larger the hole to be patched, the thicker the putty should be. Do not mix more than will be used in several hours. SWEDISH PUTTY: Add white lead, varnish, or colore-in-oil to Bestwall Spackling Compound to make Swedish Putty. SURFACE PREPARATION: The area to be patched must be clean and dry and free of loose particles. Grease should be removed with a strong solution of trisodium phosphate and soap or any good prepared wall cleaner. Then rinse the area with clear water. Glossy surfaces should be roughened with steel wool or fine sandpaper. APPLICATION: Bestwall Spackling Compound can be applied with a flexible broad knife, or trowel, or any suitable tool. Small cracks and imper fections can be repaired by one application. Large patches or deep, wide cracks usua.lly require two applications. It is recommended that the first application consist of Bestwall Patching Plaster. Allow this to harden and then follow with the final coat of Spackle. The finished repair may be sanded smooth if necessary. Patches in repaired surfaces should be primed and sealed bo as to even up the suction before redecorating. (SIGNATURE) STORE IN DRY PLACE PROTECT SPACKLING COMPOUND FROM MOISTURE AT ALL TIMES (Revised 4/l6/62) Page #D-l6 SGP 0003714 Direction ifD-17 DIRECTIONS FOB BESTWALL PATCHING PIASTER INSTRUCTIONS FOR MIXING AND APPLICATION MIXING: Add Bestwall Patching Plaster to cool or cold water (Potable) and stir to a putty, free of lumps. Generally the larger the patch, the thicker the putty should be. Do not mix more than can be used in 30 minutes. CAUTION: Do not reclaim patching plaster that has begun to harden by adding more water. It will be worthless. SURFACE PREPARATION: The areas to be patched must be clean and dry and free of loose particles. Enlarge small cracks by cutting out old plaster to form an inverted V. Dampen the entire area to be patched with water to promote adhesion between the old plaster and the new. APPLICATION: Small crack6 and imperfections are filled by using a thin putty forcing it into the cracks with a broad knife. Use the broad knife to shear off any excess plaster. Large holes and imperfections require two coats. Apply the first coat so that it nearly fills the area being patched. Allow it to harden. While the first coat is still wet, apply a second coat. Bring this coat out flush to the finished surface. Shear it off smooth with the tool. When the second cost is hard and dry, sand it to a smooth surface if necessary. Prime and seal the surface to even the suction before painting or papering. This may require priming entire area. (SIGNATURE) STORE IN DRY PLACE PROTECT PATCHING PLASTER FROM MOISTURE AT ALL TIMES Page #D-17 SGP 0003715 Direction tID-IQ 2 LBS. RETARDER DIRECTIONS To make plaster set slower, stir the necessary amount of retarder in the first bucketful of water used per mortar batch; then add sufficient clear water for plastering consistency. The required amount of Retarder can also be scattered over the plaster and sand and then thoroughly mixed with the mort8r. Usually about an ounce of Retarder (1 heaping tablespoon full) to a sack of piaster is sufficient. (SIGNATURE) Page #D-l8 SGP 0003716 Direction #D-19 LIME BAGS GENERAL SPECIFICATIONS 1. BESTWALL BUILDER'S LIME, en all purpose material, is pressure hydrated or autoclaved lime containing less than 8$ of unhydrated oxides and meets requirements of Federal Specification SS-L-351 lor Finishing Hydrated Lime, Type F and Amendment. It also meets requirements of A.S.T.M. Specifications for Special Finishing Hydrated Lime C-206-49 Type S. 2. BESTWALL BUILDER'S LIME meests requirements of Federal Specification SS-L-351 for Finishing Hydrated Lime, Type F and A.S.T.M. Specifi cations for Normal Finishing Hydrated Lime C-6-49 Type N. 3. BESTWALL BUILDER'S LIME meets requirements of Federal Specification SS-L-351 for Mason's Hydrated Lime Type M and Amendment, and A.S.T.M. Specifications for Hydrated Lime for Masonry Purposes C-207-49 Type N and Type S. DIRECTIONS FOR MIXING AND APPLICATION A. PUTTY PREPARATION Large Volume - Overnight Soaking Use 6-3/4 gallons of clean water per 50 pound bag. Sift lime slowly through metal lath or screen into water without agitating mixture. Let soak overnight. If putty is too stiff, add a little water. If too soft, add lime. Immediate Use Use 6-1/4 gallons of clean water per 50 pound bag. Sift lime slowly through metal lath or screen into water and let stand until water is taken up (15 to 30 minutes). Mixing to speed the action will not destroy workability. Page #D-19 SGP 0003717 Direction #D-19 (Continued) B. GAUGING When lime putty is ready for use, place on mixing board. Hollow out center and pour water therein. Add at least one part Bestwall Gauging Plaster to three parts of lime putty by volume and mix thoroughly. C. APPLICATION Gypsum-Lime Putty Trowel Finish Bhall be applied over a partially dry base coat or a thoroughly dry base coat which ha6 been evenly vetted by brushing or spraying (avoid excessive watering), scratched in thoroughly, laid on well, doubled back and filled out to a true, even Burfece. The general thickness shall be l/l6 to l/8 inch. The finish shall be allowed to draw a few minutes and then it shall be well-troweled with water to a smooth finish, free from cat faces and other blemishes or irregularities. D. BESTWALL BUILDER'S LIME may be used with Keene's Cement for a very hard finish, with a fine sand for a sand float finiBh, or with plastering sand for basecoat plastering. See American Standards Association A42.1-55 for specifications for such applications. E. MORTAR FOR MASONRY Bestwall Builder's Lime may be used in preparing mortars in accordance with Tentative Specifications for Mortars for Unit Masonry A.S.T.M. Designation C-270-51T. Page #D-19A SGP 0003718 Direction #D-19 (Continued) Mortar proportions by volume from that specification are as follows: o a cn s MORTAR TYPE PARTS BY VOLUME OF CEMENT PARTS BY VOLUME OF HYDRATED LIME OR LIME PUTTY AGGREGATE, MEASURED IN A DAMP, LOOSE CONDITION 1 - Portland 1 - Portland 1 - Portland 1 - Portland 1 - Portland 1/k Hot under 2-1/4 and over l/k to 1/2 not over 3 times the over l/2 to 1-1/4 sum of the volumes over 1-1/4 to 2-1/2 , of the cement and over 2-1/2 to 4 lime used. (SIGNATURE) STORE IN DRY PLACE PROTECT LIME FROM MOISTURE AT ALL TIMES Page #D-19B SGP 0003719 Direction #D-20 UI-IE BAGS GENERAL SPECIFICATIONS CAUTION: Do not uee Bestvall Mason's Lime for plastering. It may cause tp_ ops . A. BESTWALL MASON'S LIME is normal hydrated and meets requirements of Federal Specification SS-L-351 for Mason's Hydrated Lime Type M, and A.S.T.M. Specifications for Hydrated Lime for Masonry Purposes C-207-49 Type N. B. PUTTY PREPARATION Sift lime slowly through metal lath or screen into water without agitating mixture. Let it soak at least 12 hours in putty form before using. C. MORTAR FOR MASONRY Bestwall Meson's Lime may be used in preparing mortars in accord ance with Tentative Specifications for Mortars for Unit Masonry A.S.T.M. Designation C-270-51T. Mortar proportions by volume from that specification are as follows: MORTAR T{FF M S N 0 K PARTS BY VOLUME OF CEMENT | PARTS BY VOLUME [ ' OF LIME PUTTY AGGREGATE, MEASURED IN A DAMP, LOOSE CONDITION 1 - Portland 1/4 Not under 2-1/4 and 1 - Portland over 1/4 to 1/2 not over 3 times the 1 - Portland over l/2 to 1-1/4 sum of the volumes 1 - Portland ! over 1-1/4 to 2-l/2 of the cement and 1 - Portland ! over 2-1/2 to 4 I lime used. (SIGNATURE) STORE IN DRY PLACE PROTECT LIME FROM MOISTURE AT ALL TIMES Page //D-20 SGP 0003720 Direction $D-21 LIME BAGS GENERAL SPECIFICATIONS 1. BESTWALL SMOOTH FINISHING LIME is normal hydrated and meets require ments of Federal Specification SS-L-351 for Finishing Hydrated Lime Type F and A.S.T.M. Specifications for Normal Finishing Hydrated Lime C-6-49, Type N. 2. BESTWALL SMOOTH FINISHING LIME meets requirements of Federal Speci fication SS-L-351 for Mason's Hydrated Lime Type M and A.S.T.M. Specifications for Hydrated Lime for Masonry Purposes C-207-49 Typo N. DIRECTIONS FOR MIXING AND APPLICATION A. PUTTY PREPARATION Sift lime slowly through metal lath or screen into water without agitating mixture. Let Boak 24 hours. If putty is too stiff, add a little water. If too soft, add lime. B. GAUGING When lime putty is ready for use, place on mixing board. Hollow out center and pour water therein. Add at least one part Bestwall Gauging Plaster to three parts of lime putty by volume and mix thoroughly. C. APPLICATION Gypsum-Lime Putty Trowel Finish shall be applied over a partially dry base coat or a thoroughly dry base coat which has been evenly wetted by brushing or spraying (avoid excessive watering), scratched in thoroughly, laid on well, doubled back and filled out to a true even surface. The general thickness shall be l/l6 to l/8 inch. The Page flD-21 SGP 0003721 Direction #D-21 (Continued) finish shall be allowed to draw a few minutes and then it shall be well-troweled with water to a smooth finish, free from cat faces and other blemisheB or irregularities. D. BESTWALL SMOOTH FINISHING LIME may be used with Keene' s Cement for a very hard finish, with a fine sand for a sand float finish, or with plastering sand for basecost plastering. See American Standards Association A42.1-55 for specifications for such applications. E. MORTAR FOR MASONRY Bestwall Smooth Finishing Lime may be used in preparing mortars in accordance with Tentative Specifications for Mortars for Unit Masonry A.S.T,M. Designation C-270-51T. Mortar proportions by volume from that specification are as follows: MORTAR TYPE M S N 0 K PARTS BY VOLUME OF CEMENT PARTS BY VOLUME OF LIME PUTTY AGGREGATE, MEASURED IN A DAMP, LOOSE CONDITION 1 - Portland 1 - Portland 1 - Portland 1 - Portlend 1 - Portland l/4 over 1/4 to l/2 over 1/2 to l-l/4 over 1-1/4 to 2-1/2 over 2-1/2 to 4 Not under 2-1/4 and not over 3 times the sum of the volumes of the cement and ! lime UBed. (SIGNATURE) STORE IN DRY PLACE PROTECT LIME FROM MOISTURE AT ALL TIMES Page ?}D-21A SGP 0003722 Direction fi'D-22 LIME BAGS GENERAL SPECIFICATIONS CAUTION: Do not use BeBtwall Speedy Mason's Lime for plastering. It may cause "pops". A. BESTV'ALL SPEEDY MASON'S LIME is pressure hydrated or autoclaved and meets requirements of Federal Specification SS-L-351 for Mason's Hydrated Lime Type M and Amendment, and A.S.T.M. Specification for Hydrated Lime for Masonry Purposes C -207-1+9 Type N snd Type S. 3i. POTTY PREPARATION Best\/ul.l Speedy Mason's Lime does not need to be soaked before use. It may be mixed with other dry mortar ingredient. C. MORTAR FOR MASONRY Eestwall Speedy Mason's Lime may be used in preparing mortars dry (or as putty) in accordance with Tentative Specifications for Mortars for Unit Masonry A. .S.T.M. Designation C-270-51T. Mortar proportions by volume from that specification are as follows: MORTAR TYPE M S N 0 K PARTS BY VOLUME OF CEMENT 1 - Portland 1. - Portland 1 - Portland 1 - Portland 1 - Portland PARTS BY VOLUME OF EYDRATED LIME OR LIME PUTTY l/k over l/k to 1/2 over l/2 to l-l/4 over 1-1/4 to 2-1/2 over 2-1/2 to 4 AGGREGATE, MEASURED IK A DAMP, LOOSE CONDITION Not under 2-l/4 and not over 3 times the sum of the volumes of the cement and lime used. (SIGNATURE) STORE IN DRY PLACE PROTECT LIME FROM MOISTURE AT ALL TIMES Page jiH-22 SGP 0003723 Direction i?D-23 PREPARED TROWEL FINISH DIESCTIONS Mix with water only. Base plaster coat must be thoroughly set and nearly dry before finish is applied. Dampen base coat if necessary to reduce suction. Surface of base coat must be broomed or otherwise roughened to receive finish. Apply first coat thin as possible, pressing it firmly into base coat; double-back with second coat and level out to true even surface. Allow to draw, then dampen surface with water and trowel to a smooth surface. Close or screen all openings until plaster has set. Then ventilate to promote rapid drying. STORE IN DRY PLACE PROTECT PREPARED TROWEL FINISH FROM MOISTURE AT ALL TIMES Page #D-23 SGP 0003724 Direction ^D-24 BESTWALL GRABIT INSTRUCTIONS FOR MIXING AND APPLICATION READ CAREFULLY FOR: Direct attachment of gypsum wall board to interior masonry walls. May be used on poured concrete, cinder block, or concrete block walls which are reasonably straight and true and free from any surface treatment or decoration. CAUTION Add water only. Do not mix any other material or ingredients with the adhesive in this package. Use clean water suitable for drinking. Mix in a clean container, free from any previously hardened masonry adhesive or other foreign ingredients. SURFACE PREPARATION Surfaces should be reasonably straight and true and free of fragments of mortar, splinters from forms, protruding reinforcing rods, etc. Surfaces out of alignment by 1" or more should be leveled by some suitable means. MIXING Mix 50 lbs. of Grabit with 10 quarts of water. The resultant consistency is such that it may be applied with a caulking gun, yet stiff enough that the bead will not sag or flow. Mix until powder is completely wetted. Allow to soak for 5 minutes, then remix and adjust consistency by addition of small amounts of water. Do not use excessive amounts of woter. Do not mix more than can be used in 2--1/2 hours. Clean out all tools and containers before the 2-1/2 hour setting time of the adhesive has elapsed. APPLICATION Cn the back side of the board apply a 1" ribbon of Grabit to each edge, keeping the adhesive as close to the edges as possible and two ribbons in the field of the Page ^D-24 SGP 0003725 Direction ^D-24 board 16" from each edge. The ribbons of adhesive are applied parallel to the paper bound edges of the board. Position the board containing the adhesive either vertically or horizontally. Use masonry nails where necessary, to hold the board in place until the adhesive sets. To allign joints, place a 2 x 4 over the adjoining board edges and tap with a hammer. If the boards are warped, use masonry nails to pull the boards into alignment. Remove all droppings from the face of the boards before the adhesive sets. The Grabit will set hard in 3-4 hours, after which joint taping and finishing operations may be started. (Added 3/15/63) Page ^D-24A SGP 0003726 Direction ^JD-25 DIRECTIONS FOR BESTWALL JOINT SYSTEM COMPOUND * * * INSTRUCTIONS FOR MIXING AND APPLICATION READ CAREFULLY Caution: Add water only. Do not nix any other material or ingredient with the dry powder (adhesive) in thi6 packege. Use clean water (suitable for drinking) at 60 to 80 Fahrenheit. Do not beat air into the mix. Protect work from freezing. Mix 25 lbs. of Bestwall Joint System Compound (an adhesive) with 17 pints of water. If dry powder or water or both are cola, more water will be required to reach a workable consistency. Mix at about the consistency the material will be used. The wet mixture will stiffen during the first 5 to 10 minutes then, after 20 to 30 minutes soaking, will lose its stiffness. Cold water or cold povder or both may double the required soaking time. After the soaking period has elapsed, the material should be remixed until it becomes plastic and creamy. Add more water to obtain a thinner consistency if desired. Apply Bestwall Joint System Compound to b11 flat joints and shear off surplus, leaving no material on the high edges. Allow to dry for about 2 to 12 hours (depending on drying conditions) before taping. This operation will leave a uniform depth of taper for uniform shrinkage of subsequent applications under and over the tapes. Page #D-25 SGP 0003727 Direction fS'D-25 (Continued) Apply Beetwall Joint System Compound to Joints and embed tapes, leaving a uniform thickness of material under the tapes. At the same time cover all nailheads with Joint System Compound. Repeat the letter operation with each subsequent application of com pound or as many times as needed. When the Joint System Compound has lightened (anytime after surface dry), cover the taped Joint with Joint System Compound. Shear off surplus, leaving a uniform coverage over tapes with edges well feathered. The Joint System Compound under the tapeB and the first coat over the tapes must be THOROUGHLY DRY before the next coat over the JointB. Cover the Joints a second time with Joint System Compound and shear off the excess, leaving a smooth, well feathered Joint. Allow the joints to dry thoroughly before proceeding further. *** For best results cover the joints a third time with Joint System Compound. As en alternate to this step apply Joint System Compound to the entire area of board and joints and shear off tight. This operation, called a skim coat, provides the surface with a more uniform texture and Buction. *** Where a skim coat has been used to finish the wallboard, a one coat paint application may be acceptable. For best results, a prime coat should be used over the entire area before final decoration. (SIGNATURE) STORE IN DRY PLACE PROTECT COMPOUND FROM MOISTURE AT ALL TIMES Page #D-25A SGP 0003728 Direction #D-26 DIRECTIONS FOB BESTWALL ALL PURPOSE JOINT SYSTEM COMPOUND *** INSTRUCTIONS FOR MIXING AND APPLICATION READ CAREFULLY Caution: Add water only. Do not mix any other materiel or ingredient with the dry .powder (adhesive) in this package. Use clean water (suitable for drinking) at 60 to 80 Fahrenheit. Do not beet air into the mix. Protect work from freezing. Mix 25 lbs. of Bestwall All Purpose Compound with 17 pints of water. If dry powder or water or both are cold, more water will be re quired to reach a workable consistency. Mix at about the consistency the material will be used. The wet mixture will stiffen during the first 5 to 10 minutes then, after 20 to 30 minutes soaking, will lose its stiffness. Cold water or cold powder or both may double the required soaking time. After the soaking period has elapsed, the material should be remixed and more water may be added to obtain a thinner consistency if desired. Apply Bestwall All Purpose Compound to all flat Joints and shear off surplus, leaving no material on the high edges. Allow to dry for about 2 to 12 hourB (depending on drying conditions) before taping. This operation will leave a uniform depth of taper for uniform shrinkage of subsequent applications under and over the tapes. Page #D-26 SGP 0003729 Direction #D-26 (Continued) Apply Bestwell All Purpose Compound to joints end embed the tapes, leaving a uniform thickness of material under the tapes. At the same time cover ell nailheads with All Purpose Compound. Repeat the latter operation with each subsequent application of All Purpose Compound or as many times as needed. When the All Purpose Compound has whitened (anytime after surface dry), cover the taped joint with All Purpose Compound. Shear off surplus, leaving a uniform coverage over the tapes with edges well feathered. The All Purpose Compound under the tapes and the first coat over the tapes must be THOROUGHLY DRY before the next coat over the joints. Cover the joints a second time with All Purpose Compound and shear off the excess, leaving a smooth, well feathered joint. Allow the joints to dry before proceeding further. Bestwall All Purpose Compound may also be used to texture the surface of the finished wallboard surfaces. For best results, apply a vinyl primer to the entire area before texturing. The texture may be applied with a roller, 6ponge, brush or other suitable implement depending on the type of configuration deBired. For heavy textures, use about 22 pints of water end for light tex tures use about 25 pints of water per 25 lbs. of All Purpose Compound. Protect woodwork and trim during application and remove all droppings before they harden. (SIGMATUEE) STORE IN DRY PLACE PROTECT COMPOUND FROM MOISTURE AT ALL TIMES Page y,'D-26A SGP 0003730 Direction ^D-27 DIRECTIONS FOB BESTWALL CONCRETE BOND PIASTER Mix with water only. Concrete surface must he cleaned free from all dirt and oil and must be well hacked before mortar is applied. Dampen concrete surface if necessary to reduce suction. Close or screen all openings until plaster has set. Then ventilate to promote rapid drying. STORE IN DRY PIACE PROTECT CONCRETE BOND PIASTER FROM MOISTURE AT ALL TIMES SGP 0003731 Page :/,D-27 Direction ^D-28 BESTWALL GAUGING PLASTER - MEDIUM SET DIRECTIONS Bestwoii Gauging Plaster meets A.S.T.M. Specifications C-28-55 and Federal Specifications SS-P-402 Type G. Medium set gauging is retarded for use. Use with lime putty for finish coat in the proportions of one measure of dry gauging plaster to not more than three measures of lime putty. Over lightweight aggregate basecoat, add 1/2 to 1 cu. ft. of fine per lite or fine sand per 100 lbs. of gauging plaster. Base coat must be broomed or roughened. Dampen base coat if necessary to reduce suction. Apply first coat thin as possible, pressing it firmly into base coat; double back with second coat and level out to true even surface. The general thickness of the finish coat shall be 1/16 to 1/3 inch. The finish shall be allowed to draw a few minutes and then it shall be well troweled with water to a smooth finish, free from cat faces and other blemishes or irregularities. STORE IN DRY PLACE PROTECT PLASTER FROM MOISTURE AT ALL TIMES (Revised 3/30/63) Page #D-28 SGP 0003732 Direction #D-29 DIRECTIONS FOB BESTWALL IAMINATING COMPOUND *** INSTRUCTIONS FOR MIXING AND APPLICATION READ CAREFULLY Caution: Add water only. Do not mix any other material or ingredient with the contents of this package. Use clean water (suitable for drinking) at 60 to 60 Fahrenheit. Protect work from freezing. Add Bestwall Laminating Compound to water in the ratio of 1 part dry powder to 1^ parts water by weight. (4|r gallons of water for 25 lbs. of Laminating Compound or 1-g- pintB of water per 1 lb. of Laminating Compound.) Slowly add the dry powder to the water with continuous stirring. Use a wire whip or other suitable agitator to mix to a smooth paste. Allow the Laminating Compound to soak for 5 to 10 minutes. Remix and adjust the consistency, so that the Laminating Compound can be spread easily, and the applied ridges will not self level or sag when the board is held in a vertical position. Either a comb type spreader, Ames tool designed for applying Laminating Compound, or equivalent, may be used. The comb type spreader should have triangular notches 3/16" wide x 3/16" deep, spaced 3/4" on centers. Other spreaders should leave the same size and pattern of ridges as the comb type spreader. Bestwall Laminating Compound may be covered and kept overnight for the next day's use. Slight thickening or thinning may be necessary prior to use the following day. (SIGNATURE) (Revised 12/12/62) STORE IN DRY PLACE Page #D-29 SGP 0003733 Direction #D-30 DIRECTIONS FOR BESTWALL FIBERED PIASTER - MACHINE APPLICATION Bestwall Fibered Pleeter is for interior basecoat pisstoring on the following type plaster bases: gypsum lath, metal and wire lath, masonry except monolothic concrete and wood lath. Bestwall Fibered Plaster meets A.S.T.M. Specification C-28-55 and Federal Specification SS-P-402 Type N. Sand or lightweight aggregate (perlite or vermlculite) to be used with Bestwall Fibered Plaster as basecoat plastering shall conform to A.S.T.M. Specification C-35-54T. PROPORTIONING OF AGGREGATES PER 100 LBS. PLASTER SHALL NOT EXCEED THE FOLLOWING: Perlite or Vermlculite Sand (6 #2 Shovels Equc.l 1 cu. ft.) Over Gypsum Lath Two Coat Work Three Coat Work Scratch Coat Brown Coat 2 cu. ft. 2 cu. ft. 2 cu. ft. 2j cu 2 cu. 3 cu. Over Metal Lath or Wood Lath Three Coat Work Scratch Coat Brown Coat 2 cu. ft. 2 cu. ft. 2 cu. ft. 3 cu. ft. Over Masonry except Monolithic Concrete Two or Three Coat Work 3 cu. ft. 4 cu. ft. MIXING Keep tools and equipment clean. Use clean water only. For hand mixing. Dry blend the plaster and aggregate in the mortar box, then add water and blend thoroughly with the hoe. Do not mix damp (Revised 3/30/63) Page #D-30 SGP 0003734 Direction #D-30 (Continued) sand vith plaster and let stand in the box before adding water. Clean the box after each batch. For machine mixing. With the agitator running, add the approximate amount of water needed, half the aggregate, all of the plaster, and then the remainder of the aggregate, and mix thoroughly to proper consistency, adding additional water if necessary. Dump the batch when completely mixed and, if another betch is not to be mixed right away, clean out the mixer ready for next batch. APPLICATION The material in thiB bag has been formulated specifically for appli cation through a plastering machine. For best results in hand application of plaster, use regular gypsum plaeter material. For two coat work. Base or first coat shall be applied with suffi cient pressure and material to form good bond on gypsum lath or masonry as the case may be, and to cover well. Then before this scratch coat has set and without raking its surface, material of same proportions shall be doubled back to bring out to grounds and struct to a true surface with rod and darby without application of water and cross rake or scratch to provide a mechanical key for reception of finish (second coat). For three coat work. Scratch or first coat shall be applied to cover well (minimum of 3/l6" over metal lath) and with sufficient pressure and material to form good full keys on wood and metal lath, wire lath, and wire fabric, and good bond on gypsum lath or masonry. Then it Bhould be scratched to a rough surface. Page #D-3CA SGP 0003735 Direction D-30 (Continued) The brown or second cost shall be applied after the scratch coat has oet firm and hard, brought out to grounds, straightened to a true surface with rod and darby without application of water and cross rake or scratch to provide a mechanical key for reception of the finish (third coat). NOTE: Three coat work shall always be used over metal lath, wood lath, or other resilient lath. Gypsum sand float finish. Gypsum sand float finish shall he mixed in proportion of not more than 2 parts of sand by weight to 1 part of unfibered plaster. Where fibered plaster is used, the fiber should be screened from the plaster. The plaster shall be scratched in tight over the basecoat, brought out to an even surface with the trowel, and then floated to a true Eurface free from slick spots or other blemishes. PRECAUTIONS Before plastering over porous absorptive masonry, wet the surface to reduce suction and prevent shrinkage cracks. Several hours before plastering over wood lath, the lath should be wet thoroughly to prevent plaster cracking. Do not retemper. Screen openings in hot weather to prevent dryouts. Provide adequate heat in cold weather to prevent freezing. When plaster has set hard and firm, provide ventilation for adequate drying. (SIGNATURE) *** STORE IN DRY PLACE PROTECT PIASTER FROM MOISTURE AT ALL TIMES Page #D-30B SGP 0003736 Direction #D-31 DIRECTIONS FOR BESTWALL UNFIBERED PIASTER - MACHINE APPLICATION Bestwall Unfibered Piaster is for interior base coat plastering on the following plaster bases: gypsum lath, masonry except monolithic concrete. It is also suitable for interior gypsum sand float finish. Bestwall Unfibered Plaster meets A.S.T.M. Specification No. C-20-55 and- Federal Specification SS-P-402 Type N. Sand or lightweight aggregate (perlite or vermiculite) to be used with Bestwall Unfibered Plaster as basecoat plastering, shall conform to A.S.T.M. Specification C-35-54T. NOTE: When to be used in gypsum sand float finish, the sand shall pass a No. 12, 16, or 20 mesh sieve, depending on the texture of the surface desired. PROPORTIONING OF AGGREGATES PER 100 LBS. PLASTER SHALL NOT EXCEED THE FOLLOWING: Perlite or Vermiculite Sand (6 #2 Shovels Equal 1 cu. ft.) Over Gypsum Lath Two Coat Work Three Coat Work Scratch Coat Brown Coat Metal Lath or Wood Lath 2 cu. ft. 2 cu. ft. 2 cu. ft. 2-| cu. ft 2 cu. ft. 3 cu. ft. Three Coat Work Scratch Coat Brown Coat 2 cu. ft. 2 cu. ft. 2 cu. ft. 3 cu. ft. Over Masonry except Monolithic Concrete Two or Three Coat Work 3 cu. ft. 4 cu. ft. (Revised 3/30/63) Page #D-31 SGP 0003737 Direction #D-31 (Continued) MIXING Keep tools and equipment clean. Use clean vater only. For hand mixing. Dry blend the plaster and aggregate in the mortar box, then add vater and blend thoroughly with the hoe. Do not mix damp sand with plaster and let stand in the box before adding water. Clean the box after each batch. For machine mixing. With the agitator running, add the approximate amount of water needed, half the aggregate, all of the plaster, and then the remainder of the aggregate, r.nd mix thoroughly to proper consistency, adding additional water if necessary. Dump the batch when completely mixed and, if another batch is not to be mixed right away, clean out the mixer ready for next batch. APPLICATION The material in this bag haB been formulated specifically for appli cation through a plastering machine. For best results in hand application of plaster, use regular gypBum plaster material. For two coat work. Base or firBt coat Bhall be applied with suffi cient pressure end material to form good bond on gypsum lath or masonry ac the case may be, and to cover well. Then before this scratch coat has set and without raking its surface, material of same proportions Bhall be doubled back to bring out to grounds and struck to a true surface with rod and darby without application of water and cross rake or scratch to provide a mechanical key for reception of the finish (second coat). Page #D-31A SGP 0003738 Direction #D-31 (Continued) For three coat work. Scratch or first coat shall be applied to cover well and with sufficient pressure and material to form good bond on gypsum lath and masonry. Then it should be scratched to a rough surface. The brown or second coat shall be applied after the scratch coat has set firm and hard, brought out to grounds, straightened to a true surface with rod and darby without application of water and cross rake or scratch to provide a mechanical key for reception of the finish (third coat). NOTE: Three coat work Bhall always be ueed over metal lath or other resilient lath. Gypsum sand float finish. Gypsum sand float finish shall be mixed in proportion of not more than 2 parts of sand by weight to 1 part of unfibered piaster. The plaster shall be scratched in tight over the basecoat, brought out to an even surface with the trowel, and then floated to a true surface free from slick spots or other blemishes. PRECAUTIONS Before plastering over porous absorptive masonry, wet the surface to reduce suction and prevent shrinkage cracks. Several hours before plastering over wood lath, the lath should be wet thoroughly to prevent plaster cracking. Do not retemper. Screen openings in hot weather to prevent dryouts. Provide adequate heat in cold weather to prevent freezing. When plaster has set hard and firm, provide ventilation for adequate drying. (SIGNATURE) *** STORE IN DRY PLACE PROTECT PLASTER FROM MOISTURE AT ALL TIMES Page #D-31B SGP 0003739 Direction #D-32 DIRECTIONS FOR BESTWALL ACOUSTICAL PIASTER USE ThiB le a mill mixed product to be mixed with clean water only for machine or trowel application over gypsum basecoat plasters, monolithic concrete and other surfaces which are firm, clean and free of efflorescence or water soluble substances. Gypsum baeecoats should be half dry to dry. Concrete should be dry. MIXING Be sure equipment and tools are clean. Machine mix at least 5 minutes. If hand mixed, hoe until thoroughly mixed. APPLICATION SPRAY APPLICATION - For first cost use 55 - 65 quarts water per 40 lb. bag. Apply 3/8" thick. Level with darby and allow to dry before applying finish coat. For finish coat, use 5 to 10 additional quarts water per bag depending on the texture desired. When applied over low suction bases, the material should be applied in three applications, the first application furnishing the suction for subsequent coats. Any large fissures in the base coat should be filled and leveled before applying finish coat. HAND APPLICATION - Uee 50 - 60 quarts water per 40 lb. bag for both basecoat and finish coat. Apply basecoat 3/8" thick, allow to dry, then apply finish coat l/8" thick. Trowel finish may be smooth troweled, floated, stippled, or darbied after it haB taken-up sufficiently. Page #D-32 SGP 0003740 Direction #D-32 (Continued) PRECAUTIONS Provide adequate heat and ventilation in alow drying weather. Avoid too rapid drying to minimize excessive cracking. Use only on ceilings and other areas which are not subject to abrasion or free moisture. Cover any exposed metal with rust resistant paint before applying Bestwall Acoustical Plaster. Page ^D-32A SGP 0003741 Direction i!D-33 DIRECTIONS FOR BESTWALL BESTEX TEXTURE PAINT - WHITE *** INSTRUCTIONS FOR MIXING AND APPLICATION FOR USE OVER MOST INTERIOR SURFACES READ CAREFULLY CBUtion: Use clean water (suitable for drinking) at 60 to 80 Fahrenheit. Be sure mixing equipment is clean. Do not beat air into the mix. Protect work from freezing. Add 25 lbs. of Bestvall Bestex to 19 pints of water and mix until the dry powder 1b completely wetted. Allow the mix to Boak for 20 to 30 minutes. After the mix has soaked, add water as nec essary to obtain the desired consistency and. remix. For heavy textures use about 25 to 27 pints total water and for lighter textures use about 32 to 3^ pints total water per 25 lbs. of dry Bestex. For application over old surfaces, wash off any water soluble coatings, remove old paint with trisodium phosphate or other strong deter gent and rinse with clean water. Roughen glossy surfaces with sandpaper or steel wool and fill cracks with Bestwall Patching Plaster or Speckling Compound. When such surfaces are dry, apply a vinyl primer or equivalent to even suction over the entire area before texturing. Finish gypsum wallboard surfaces with Bestwall Joint System material. For best results, apply a vinyl primer to the entire area before texturing. Page ^D-33 SGP 0003742 Direction #D-33 (Continued) Texturing may be accomplished by using a roller, brush, sponge, or other suitable implement depending on the type of configuration desired. Protect woodwork and trim during application and remove all droppings before they harden. If it is desired to tint the texture, as well aB obtain increased durability, latex paintB may be added in the amount of 1 gallon per 25 lb. bag of Beotex. The addition of paint should be made after the 20 to 30 minute soaking period. (SIGNATURE) STORE IN DRY PLACE PROTECT TEXTURE FROM MOISTURE AT ALL TIMES. (Revised 12/12/62) Page #D-33A SGP 0003743 Direction #D-34 DIRECTIONS FOE EESTWALL HESTKX TEXTURE PAINT - WHITE FOR SPRAY APPLICATION ONLY INSTRUCTIONS FOR MIXING AND APPLICATION FOR USE OVER MOST INTERIOR SURFACES READ CAREFULLY CAUTION: Use clean water (suitable for drinking) at 60 to 80 Fahrenheit. Be sure mixing equipment is clean. Do not beat air into the mix. Protect work from freezing. FOR SPRAY APPLICATION OF BESTEX: 1. Add contents of this bag to 17 pints of water and mix until the dry powder is completely wetted. 2. Allow the mix to soak for 15 minutes. 3. After the mix has soaked, remix and add water as necessary to obtain the desired consistency. It is desirable to use about 18 to 19 pints total water. FOR SPRAY APPLICATION OF BESTEX WITH PERLITE: 1. Add contents of this bag to 17 pints of water and mix until the dry powder is completely wetted. 2. Allow the mix to Boak for 15 minutes. 3. After the mix has soaked, remix and add water as necessary to obtain the desired consistency and remix. It is desir able to use 20 to 26 pints total water depending upon the desired texture. 4. Add l'g- to 13^ lbs. of perlite, depending upon the coarseness of texture desired and remix until thoroughly blended. For best results, use perlite which will all pass through a 20 mesh screen. Page #D-34 SGP 0003744 Direction #D-34 (Continued) For best coverage and uniformity of texture, spray a given area by first applying vertically and then immediately doubling back with a horizontal application. For application over old surfaces, wash off any water soluble coatings, remove old paint with trisodium phosphate, or other strong detergent and rinse with clean water. Roughen glossy surface with sandpaper or steel wool and fill cracks with Bestwall Patching Plaster or Speckling Compound. When such surfaces are dry, apply a vinyl primer or equivalent to even suction over the entire area before texturing. Finish gypsum wallbcurd surfaces with Bestwall Joint System material. For best results, apply a vinyl primer to the entire area before Bpraying texture. Protect woodwork and trim during application and remove all droppings before they harden. If it is desired to tint the texture, as well as obtain increased durability, latex paints may be added in the amount of 1 gallon per 25 IB bag of Bestex. The addition of paint should be made after the 20 to 30 minute soaking period. (SIGNATURE) STORE IN DRY PLACE PROTECT TEXTURE FROM MOISTURE AT ALL TIMES (Revised 12/12/62) Page #D-34A SGP 0003745 Direction #D-35 DIRECTIONS FOR BESTWALL FIBERED TWIN COAT PIASTER Bestwall Fibered Piaster is for interior basecoat plastering on the following type plaster bases: gypsum lath, metal and wire lath, masonry (except monolithic concrete) and wood lath. Bestwall Fibered Plaster meets A.S.T.M. Specification C-28-60 and Federal Specification SS-P-402 Type N. Sand or lightweight aggregate (perlite or vermiculite) to be used with Bestwall Fibered Plaster as basecoat plastering shall conform to A.S.T.M. Specification C-35-57T. PROPORTIONING OF AGGREGATES PER 100 LBS. PLASTER SHALL NOT EXCEED THE FOLLOWING: Perlite or Vermiculite Sand (6 &2 Shovels Equal 1 cu. ft.) Over Gypsum Lath Two Coat Work Three Coat Work Scratch Coat Brown Coat 2 cu. ft. 2 cu. ft. 2 cu. ft. 2j cu. ft 2 cu. ft. 3 cu. ft. Over Metal lath or Wood Lath Three Coat Work Scratch Coat Brown Coat 2 cu. ft. 2 cu. ft. 2 cu. ft. 3 cu. ft. Over Masonry except Monolithic Concrete Two or Three Coat Work 3 cu. ft. 4 cu. ft. MIXING Keep tools and equipment clean. Use clean water only. For hand mixing. Dry blend the plaster and sggregate in the mortar box, then add water and blend thoroughly with the hoe. Do not mix damp Page #D-35 SGP 0003746 Direction #D-35 (Continued) Band wjth plaster and let stand in the box before adding water. Clean the box after each batch. For machine mixing. With the agitator running, add the approximate amount of water needed, half the aggregate, all of the plaster, and then the remainder of the aggregate, and mix thoroughly to proper consistency, adding additional water if necessary. Dump the batch when completely mixed and, if another batch is not to be mixed right away, clean out the mixer ready for next batch. HAND APPLICATION For two coat work. Base or first coat shall be applied with suffi cient pressure end material to form good bond on gypsum lath or masonry as the case may be, and to cover well. Then before this scratch coat has set and without raking its surface, material of same proportions shall be doubled back to bring out to grounds and struck to a true surface with rod and darby without application of water and cross rake or scratch to provide a mechanical key for reception of finish (second coat). For three coat work. Scratch or first coat shall be applied to cover well (minimum of 3/l6" over metal lath) and with sufficient pressure and material to form good full keys on wood and metal lath, wire lath and wire fabric,, and good bond on gypsum lath or masonry. Then it should be scratched to a rough surface. The brown or second coat shall be applied after the scratch coat has set firm and hard, brought out to grounds, straightened to a true surface with rod and darby without application of water and cross rake Page #D-35A SGP 0003747 SGP 0003748 Direction #D-35 (Continued) or scratch to provide a mechanical key for reception of the finish (third coat). NOTE: Three coat work shall always be used over metal lath, wood lath, or other resilient lath. MACHINE APPLICATION For machine application, the plaster usually is applied at a slightly thinner consistency thsn for hand application but use of excessive water must be evoided. When machine applying scratch coat to metal loth, the material must be applied agsinst the flat surface of the mesh to prevent excessive blow through. All other directions for hand application also apply to machine application. * Gypsum Band float finish. Gypsum sand float finish shall be mixed in proportion of not more than 2 parts of sand by weight to 1 part of unfibered plaster. Where fibered plaster is used, the fiber should be screened from the plaster. The plaster shall be scratched in tight over the basecoat, brought out to an even surface with the trowel, and then floated to a true surface free from slick spots or other blemishes. PRECAUTIONS Before plastering over porous absorptive masonry, wet the surface to reduce suction and prevent shrinkage cracks. Several hours before plastering over wood lath, the lath should be wet thoroughly to prevent plaster cracking. Fege #D-35B SGP 0003749 Direction #D-35 (Continued) Do not retemper. Screen openings in hot weather to prevent dryouts. Provide adequate heat in cold weather to prevent freezing. When plaster has set hard end firm, provide ventilation for adequate drying. (SIGNATURE) *** STORE IN DRY PLACE PROTECT PLASTER FROM MOISTURE AT ALL TIMES Page rD-35C SGP 0003750 Direction #D-36 DIRECTIONS FOR BESTWALL UNFIBERED TWIN COAT PIASTER Be8twall Unfibered Plaster is for interior basecoat plastering on the following type plaster bases: gypsum lath, metal and wire lath, masonry (except monolithic concrete) and wood lath. Bestwall Unfibered Plaster meets A.S.T.M. Specification C-28-60 and Federal Specification SS-P-402 Type N. Sand or lightweight aggregate (perlite or vermiculite) to be used with Bestwall Unfibered Plaster as basecoat plastering shall conform to A.S.T.M. Specification C-35-57T. PROPORTIONING OF AGGREGATES PER 100 LBS. PLASTER SHALL NOT EXCEED THE FOLLOWING: Perlite or Vermiculite Sand (6 #2 Shovels Equal 1 cu. ft.) Over Gypsum Lath Two Coat Work Three Coat Work Scratch Coat Brown Coat 2 cu. ft. 2 cu. ft, 2 cu. ft. cu. ft. 2 cu. ft. 3 cu. ft. Over Metal Lath or Wood Lath Three Coat Work Scratch Coat Brown Coat 2 cu. ft, 2 cu. ft, 2 cu. ft. 3 cu. ft. Over Masonry except Monolithic Concrete Two or Three Coat Work 3 cu. ft. MIXING 4 cu. ft. Keep tools and equipment clean. Use clean water only. For hand mixing. Dry blend the plaster and aggregate in the mortar box, then add water and blend thoroughly with the hoe. Do not mix damp Page ^D-36 SGP 0003751 Direction #D-36 (Continued) sand with plaster and let stand in the box before adding water. Clean the box after each batch. For machine mixing. With the agitator running, add the approximate amount of water needed, half the aggregate, all of the plaster, and then the remainder of the aggregate, and mix thoroughly to proper consistency, adding additional water if necessary. Dump the batch when completely mixed and, if another batch is not to be mixed right away, clean out the mixer ready for next batch. HAND APPLICATION For two coat work. Base or first coat shall be applied with suffi cient pressure and material to form good bond on gypsum lath or masonry as the case may be, and to cover well. Then before this scratch coat has set and without raking its surface, material of same proportions shall "be doubled back to bring out to grounds and struck to a true surface with rod and darby without application of water and cross rake or scratch to provide a mechanical key for reception of finish (second coat). For three coat work. Scratch or first coat shall be applied to cover well (minimum of 3/l6" over metal loth) and with sufficient pressure and material to form good full keys on wood and metal lath, wire lath end wire fabric, and good bond on gypsum lath or masonry. Then it should be scratched to a rough surface. The brown or second coat shall be applied after the scratch coat has set firm and hard, brought out to grounds, straightened to a true surface with rod and darby without application of water and cross rake or scratch Page #D-36A SGP 0003752 Direction ifD-36 (Continued) to provide a mechanical key for reception of the finish (third coat). NOTE: Three coat work shall always be used over metal lath, wood lath, or other resilient lath. MACHINE APPLICATION For machine application, the plaster usually is applied at a slightly thinner consistency than for hand application but use of excessive water muBt be avoided. When machine applying scratch coat to metal lath, the material must be applied against the flat surface of the mesh to prevent excessive blow through. All other directions for hand application also apply to machine application. Gypsum sand float finish. Gypsum sand float finish shall be mixed in proportion of not more than 2 parts of sand by weight to 1' part of unfibered plaster. The plaster shall be scratched in tight over the basecoat, brought out to an even surface with the trowel, and then floated to a true surface free from slick spots or other blemishes. PRECAUTIONS Before plastering over porous absorptive masonry, wet the surface to reduce suction and prevent shrinkage cracks. Several hours before plastering over wood lath, the lath should be wet thoroughly to prevent plaster cracking. Page #D-36B SGP 0003753 Direction #D-36 (Continued) Do not retemper. Screen openings in hot weather to prevent dryouts. Provide adequate heat in cold weather to prevent freezing. When plaster has set hard and firm, provide ventilation for adequate drying. (SIGNATURE) *#* STOKE IN DRY PLACE PROTECT PLASTER FROM MOISTURE AT ALL TIMES Page 7/D-36C SGP 0003754 HESTWALL FIVE STAR JOINT SYSTEM * *** *** ****** * Direction #D-37 (AN ADHESIVE) * Long vet life permits large quantities of cement to be mixed at one time without danger of spoilage within 30 days. This makes it possible to eliminate mixing on the job and also eliminates waste due to spoilage. * Fast drying allows more operations to be completed in a given period of time and minimizes delayed shrinkage. * Low shrinkage may, in some cases, reduce the number of coats required. * Superior working qualities make the cement easier to apply, reduce sanding, and reduce waste, since the cement retains its workability as it is used. * Outstanding skim coating properties make this operation easier to per form and more desirable. The uniformly smooth surfaces which result from skim coating give a better base for the decoration and make acceptable one coat paint jobs possible. ***** IN ORDER TO TAKE FULL ADVANTAGE OF THE QUALITIES OF BESTUALL FIVE STAR JOINT CEMENT READ CAREFULLY INSTRUCTIONS FOR MIXING AND APPLICATION CAUTION: Add water only. Do not mix any other material or ingredient with the contents of this package. All mixerB, tools, buckets, pumps, etc., must be absolutely clean and entirely free of any Page #D-37 SGP 0003755 Direction #D-37 (Continued) other cement. Use clean water (suitable for drinking) at 60 to 80 Fahrenheit. Do not beat air into the mis. MIXING: Mix 40 lbs. of Bestwall Five Star with 12 to 14 pints of water. Use 20 gallons of water for 500 lbs. of cement, 40 gallons of water for 1000 lbs. of cement, etc. For best results use a drill type mixer or other suitable mixer for small quantities and a ribbon or other suitable mechanical mixer for large quantities. Mix until all of the powder is completely wetted. Allow the cement to soak for at least an hour prior to use and preferably overnight. The mixed cement may be kept for at least a month in a sealed container or by merely keeping a layer of water over the surface. Prior to use, remove the surface water and remix the cement with a potato masher, drill, or other suitable agitator. Adjust to the desired consistency and mix until the cement is smooth and plastic. APPLICATION: Apply the mixed Bestwall Five Star Cement to the joints and embed the tapes, leaving e uniform thickness of material under the tapes. At the same time, cover all nailheads. Re peat the lotter operation with each subsequent application of cement or as many times as needed. When the Bestwall Five Star Cement has thoroughly dried, apply a coat over the tape. If necessary, another coat may be applied. The cement under and over the tape must be thoroughly dry before the next coat is applied. Usually ceiling joints will require one coat more than sidewall joints. Page #D-37A SGP 0003756 Direction #D-37 (Continued) For best results, apply Bestwall Five Star Joint Cement to the entire area of the board and Joints and shear off tight to get uniform suction and uniformly smooth surfaces. This is called a skim coat. In some cases, this operation will take the place of the final coat over the nail6 and joints. If any bags be come broken, use them first. Rotate stock and use the oldest material first. STORE IN DRY PLACE PROTECT CEMENT FROM MOISTURE AT ALL TIMES Page #D-37B SGP 0003757 MOLDING PIASTER BAGS RAG NO. P-1650 Bestwall Molding Plaster Beg; - Pasted Valve (Stepped End) - Construction 2jb OK-2/50K for lOOtf, 2/4OK -1/50K for 50# - Natural brown color kraft Patent Number - None - Printed one side - edges - top and bottom Light. Blue - Gross weight to be specified on purchase order - Direction No. NONE. BAG NO. P-1651 Bestwall Molding Plaster Bag - Pasted Valve (Stepped End) - Construction 1AOK-I/90AL-2/5OK for IOO7/ j I/LCK-I/9OAL-I/5OK for 50/r - Natural brown color kraft - Patent Number - None - Printed one side - edges top and bottom Light Blue - Gross weight to be specified on purchase order - Direction No. NONE. AL sheets to have overall perforations. (Devised -/lj/6r) Page f, 38 SGP 0003758 Direction //D-38 1 DAY JOINT COMPOUND BAG DIRECTIONS INSTRUCTIONS - HEAD CAREFULLY GENERAL 1) Bestwall 1 Day Wallboard Joint Compound is to be used for taping and all coats preceding the final coat in the finiehing of joints, con cealing of nailheads and co-rner bead in gypsum wallboard construction. 2) Bestwall 1 Day Wallboard Joint Compound is formulated to harden in 2|- to 3 hours. The working life is approximately 2 hours. 3) When hardened BoBtwall 1 Day Wallboard Joint Compound will not shrink. 4) Material from a previously mixed batch added to a freshly mixed batch will shorten the working life. 5) Where joint system textures are to be used as decoration or part of the decorating scheme, a vinyl primer sealer or equivalent must be applied to entire surface to be decorated prior to texturing. MIXING 1) Mix 25 lbs. of Bestwall 1 Day Wallboard Joint Compound with 13 pints of water. 2) Allow mix to soak 5 minutes. 3) Remix, adding additional water if necessary to obtain the desired working consistency. APPLICATION 1) Apply Bestwall 1 Day Wallboard Joint Compound to joints and embed tapes, leaving a uniform thickness of material under the tapes. 2) Apply first coat over tapes as soon aB compound under tapes has hardened to a point where movement of the tapes will not occur while (Added 12/7/62) Page f^D-38 SGP 0003759 Direction #D-38 (Continued) performing this application. At this time, fill corner bead. Nailheads may be spotted at convenient intervals as soon as previous spots are partially or completely hardened. 3) Apply final tight coat over previous Bestwall 1 Day Wallboard Joint Compound coats with Bestwall Topping Compound or other Bestwall finishing compounds as soon as the Bestwall 1 Day Wallboard Joint Compound applications have completely hardened. FOB BEST FF.CTH-TS 1) Add only clean (potable) water to the contents of this bag. Water temijeraturos should be to - o0 F. 2) Do not mix any other material or ingredients with the dry powder in this package. 3) Do not beat air into mix. 4) Mix only enough material for 2 hours use. If Blight stiffening should occur, a small amount of water may be added to obtain a more workable consistency. 5) Mixing pails and tools must be thoroughly clean. 6) Mixing tools should be cleaned after each use, otherwise hardened material will be difficult to remove. 7) Freshly mixed batches must be kept free of previously mixed material or working life may be shortened considerably. 8) Do not use as the final finish coat on joints, nails, or corner bead. Use Bestwall Topping Compound or other Bestwall finishing products for this purpose. (Added 12/7/62) Page #D-38A SGP 0003760 Direction B~3S (Continued) 9) Where joint system textures are to be used as decoration or part of the decorating scheme, a vinyl primer sealer or equivalent must be applied to entire surface to be decorated prior to texturing. 10) Protect vork from freezing. STORE IN DRY PIACE (Added 12/7/62) Page #D-38B SGP 0003761 Direction ^D-39 DIRECTIONS FOR BESTWALL ALL PURPOSE (WITH TAPE) JOINT SYSTEM COMPOUND ** * INSTRUCTIONS FOR MIXING AND APPLICATION READ CAREFULLY Caution: Add water only. Do not mix any other material or ingredient with the dry powder (adhesive) in this package. Use clean water (suitable for drinking) at 60 to 80 Fahrenheit. Do not beat air into the mix. Protect work from freezing. Mix 18 lbs. of Bestwall All Purpose Compound with 12-1/2 pints of water. If dry powder or water or both are cold, more water will be required to reach a workable consistency. Mix at about the consistency the material will be used. The wet mixture will stiffen during the first 5 to 10 minutes then, after 20 to 30 minutes soaking, will lose its stiffness. Cold water or cold powder or both may double the required soaking time. After the soaking period has elapsed, the material should be remixed and more water may be added to obtain a thinner consistency if desired. Apply Bestwall All Purpose Compound to all flat joints and shear off surplus, leaving no material on the high edges. Allow to dry far about 2 to 12 hours (depending on drying conditions) before taping. This operation will leave a uniform depth of taper for uniform shrinkage of subsequent applications under and over the tapes. (Added 5/17/63) Page #D-39 SGP 0003762 Direct-ion ^D-39 (Continued) Apply Bestwall All Purpose Compound to joints and embed the tapes, leaving a uniform thickness of material under the tapes. At the same time cover all nailheads with All Purpose Compound. Repeat the latter operation with each subsequent application of All Purpose Compound or as many times as needed. A'hen the All Purpose Compound has whitened (anytime after surface dry), cover the taped joint with All Purpose Compound. Shear off surplus, leaving a uniform coverage over the tapes with edges well feathered. The All Purpose Compound under the tapes and the first coot over the tapes must be THOROUGHLY DRY before the next coat over the joints. Cover the joints a second time with All Purpose Compound and shear off the excess, leaving a smooth, well feathered joint. Allow the joints to dry before proceeding further. Bestwall All Purpose Compound may also be used to texture the surface of the finished wallboard surfaces. For best results, apply a vinyl primer to the entire area before texturing. The texture may be applied with a roller, sponge, brush or other suitable implement depending on the type of configuration desired. For heavy textures, use about 14 pints of water and for light textures use about 18 pints of water per 13 lbs. of All Purpose Compound. Protect woodwork and trim during application and remove all droppings before they harden. (SIGNATURE) STORE IN DRY PLACE PROTECT COMPOUND FROM MOISTURE AT ALL TIMES (Added 5/17/63) Page '*,D-39A SGP 0003763 Direction #D-1*0 BES1VJ/.LL DENS-COTE SMOOTH FINISH INSTRUCTIONS - Road Carefully For: Application over Bestwall Dene-Cote Gypsum Base. MIXING 1) Any good mechanical mixer may be used. Add one bag (100 lb.) of Dens-Cote Smooth Finish to U gallons of water with the mixer turning. When the dry mix is wetted, bring the mix to the desired consistency with additional water, A good working consistency will require approximately U-2 gallons of water per bag (100 lb.) of Dens-Cote Smooth Finish. 2) Mix about 3 minutes or until the material is lump free. Do not overmix. 3) Dens-Cote Smooth Finish normally has a 1 to 1-| hour working time, so do not mix more than can be applied and finished in that length of time. 1) Flush mixing equipment and carrying containers with water after each batch. Material from a previous batch mixed in with a fresh batch will shorten the setting time. APPLICATION 1) Use 2" wide glass fiber mesh (7 x 11) to reinforce all flat joints and angles. Use 1" x ln perforated metal beads for corners. Corner beads should be set to regulate plaster thickness at l/8n. Nail or screw comer bead to framing member. For best results, apply the mesh by embedding it with Dens-Cote Smooth Finish, This is accomplished by troweling a layer of Dens-Cote Smooth Finish over the joint area and pressing the glass fiber mesh into the Dens-Cote (Revised 5/l5/6k) Page #D-1*0 SGP 0003764 Direction #D-1*0 Continued Smooth Finish with e trowel* The mesh may be first fltepled to the Dens-Cote gypsum base, if desired* In any case, the mesh must be embedded with Dens-Cote Smooth Finish before the over-all application begins* At the same time, fill all metal corner beads* These areas may be allowed to set before the over-all application is commenced* This preliminary embedding of the joints keep the glass fiber mesh from wrinkling, promotes uniform takeup, and assures positive keying of Dens-Cote Smooth Finish into the mesh* 2) Trowel the first coat tightly over the entire wall or ceiling surface. This application should be a minimum of l/l6n thick* 3) As soon as the first coat has taken up (10-15 mins*), double back with a leveling coat, which will bring the total thickness applied to a minimum of 3/32"* 1*) After the second coat is well taken up (15-20 mins*), begin final troweling, using water if required* The final troweling must be completed before the set takes place, as evidenced by darkening of the surface* 5) Make joinings at angles* Ceilings should be done first, then side walls* 6) Coverage of Dens-Cote Smooth Finish is 18-20 square yards (3/32" thick) per 100 lb* bag* FOR BEST RESULTS 1) Maintain a temperature of at least 55^F* in the working area 2h hours, before, during, and after application* 2) In hot dry weather, reduce drafts and ventilation by covering door and window openings* (Revised 5/15/6U) Page #D-liQA SGP 0003765 Direction /,'D-bO 3) Plan the tot'- s that it proceeds in an orderly fashion from one end of the surface to the other. This will promote a progressively uniform take up. GaUTI i-l 1} Joints may be visible if minimum thickness of 3/32" is not maintained, especially on ceilings. 2) Use only clean potable water with DeHB-Cote Smooth Finish. 3) Keep mixing equipment and tools clean at all times. It) Do not lix retarders, accelerators, or any oth r ingredient with Dens-Cote Smo >th Finish. 5) Keep Fens-Cote Smooth Finish from freezing until it is set and dry. 6) Use only Cest.wall 1 ens-Cote Gypsum Base for Dens-Cote Smooth Finish aoplication. 7) Do not attempt to rotemper ens-Cote Smooth Finish. ..TO .... Iti A I Iff rLri.CL (Revised 6/10/34) Page ^D-40B SGP 0003766 INDEX FLINTKOTE BAGS DESCRIPTION INSTRUCTIONS Joint System Compound (without tape) Miniature Joint System Compound (with tape) Miniature Joint Bedding Miniature Joint Topping Miniature All Purpose Miniature Laminating Compound Miniature Texture (Neutral) Miniature All Purpose (with tape) Miniature Fast Finish Miniature PAGE NUMBER F-l F-2 F-3 F-4 F-5 F-6 F-7 F-8 F-9 F--10 (Revised 9/20/63) SGP 0003767 INSTRUCTIONS Flintkote bags take the same number as Bestwall bags, except the "P" has been omitted and "F" has been added to represent Flintkote. These bags will have the same construction as that shown under the Bestwall bag number. The bag size and valve size will be the same as the corresponding Bestwall bag. Bestwall patent numbers are to be printed on these bags. They will be the same as on the corresponding Bestwall bags. The directions for these bags are not shown separately as are the Bestwall directions. Directions and other copy must be taken from the miniatures. The direction number shown under the Bestwall bag number does not apply. Ink colors are to be as shown on the miniature. Color of outer kraft ply to be the same as miniature. (Revised 7/24/63) Page *F-1 SGP 0003768 iX I i\ SGP 0003769 V3 r i Bag. No Pare Nn.- F4 SGP 0003770 A1NO ONIddOl KOd (Soiddoj^ ^UlQfJ34P^Jr *' Bg. No!L~lJ!jjj^ PageWn. F S-1* SGP 0003771 /' r*. > * W" n ,, Mr Bag. ^ r : - <.f l 1 1054: " Page No.----- ---S--. 1 SGP 0003772 .7 . -114:^ i mOlll. - .alW* . .. ..tII ec _'li '%V - , 1^ |mnoiuU>J I Ay,i!iJjjjp^2is f >) ? h'V i4> 7 * * f* " **/ ft ty'-r- ' 'ft ' .. r-.i*v&-:.I-I.-''(- ; '-i'1 >w ` -'f %L 4--: "4 JAM 1964 inatingOo>mpom4^^^ ' ' FLIHTKOIEi Laminating Compound, " FO UKIDMIK6 GIKW WIllKUtt Ba| NelliiM :; Page No*k2_^MWi SGP 0003773 T e x tu re I Page No.- SGP 0003774 t *; ^ ... ,}r. rL -J '' ;vnf .^6'.. X*" . v3~ -r..$T., i' * . * vv>r.;-,v >< *#: --. -v ** *.. ' V : to Mini *xt* 4dcwwwraa* as wot iosu m& ' ,r^ .,V jy^ **#. . ' ::o. ..... ................. .......... _. UgU.:f-Wf^ Fog* Vo. F-9 SGP 0003775 omiojwoo iwiof aavooni/M XSVj|.it&i'i4 iniu WALLBOARD JOINT COMPOUND SGP 0003776 INDEX BIG HORN BAGS DESCRIPTION INSTRUCTIONS Joint System Compound Miniature Joint System with tape Miniature Joint System Bedding Compound Miniature . Joint System Topping Compound Miniature Joint System All Purpose Miniature PAGE NUMBER BH-1 BH-2 BH-3 BH-4 BH-5 BH-6 (Revised 5/17/63) SGP 0003777 INSTRUCTIONS Big Horn bags take the same number as Bestwall bags, except the "P" is omitted and "BH" is added to represent Big Horn. These bags will have the same construction as that shown under the Bestwall bag number. The bag size and valve size will likewise be the same as the corresponding Bestwall bag. Bestwall patent numbers are to be printed on these bags. They will be the same as on the corresponding Bestwall bag. The directions for these bags are not shown separately as are the Bestwall directions. Directions and other copy must be taken from the miniatures. The direction number shown under the Bestwall bag number does not apply. Ink colors are to be as shown on the miniature. Color of outer Icraft ply is to be the same as miniature. (Revised 7/24/63) Page ^ BH-1 SGP 0003778 JOINT SYSTEM COMPOUND l a i N i r SYSTEM! COMPOUND) aNnodiAioD W31SAS INlOf NHOH oia VJ a. BIG HORN, JOINT SYSTEM COMPOUND SGP 0003779 Bag. No. BH 105 0 a --j i mi'TiniU) * T Bn 2 IAI3ISAS INlOf NHOH Die J O IN T SYSTEM BIG HORN, JOINT SYSTEM Bfl 105 1, Bag. No.- Page No. BH 3 ' SGP 0003780 GNflOdlAICO 9Niaa38 IAJ31SAS lNIOr NHOH DIS BEDDING COMPOUND BEDDING COMPOUND B fl I 0 5 2. Bag. No. II B TT 4 TOPPING COMPOUND TOPPING COMPOUND ONflOdWOD ONIddOi miSAS INlOf MHOH oie BIG HORN. JOINT SYSTEM TOPPING COMPOUND SGP 0003782 Bag. No. B H 10 5 3 INDEX JOHNS MANVILIE BAGS DESCRIPTION INSTRUCTIONS Glass Fibered Miniature Unfibered Minieture Extra Fibered Miniature Fibered for Machine App. Minieture Unfibered for Machine App. Miniature Light Mix Glass Fibered Miniature Light Mix Unfibered Miniature Light Mix Glass Fibered for Machine App. Miniature Light Mix Masonry Miniature Gauging Slow Set Miniature Gauging Quick Set Miniature Keenee Cement Regular Set Miniature Keenes Cement Quick Set Miniature Joint System Compound (no tape) Miniature Joint System (with tape) Miniature Joint System Bedding Compound Miniature Joint System Topping Compound Miniature Joint System Multi-Purpose Compound Miniature Laminating Compound Miniature Texture Miniature Special Plaster Miniature Hitzelberger Agricultural Gypsum Miniature Fast Set Compound Miniature PAGE NUMBER JM-1 JM-2 JM-3 JM-4 JM-5 JM-6 JM-7 JM-8 JM-9 JM-10 JM-11 JM-12 JM-13 JM-14 JM-15 JM-16 JM-17 JM-lS JM-19 JM-20 JM-21 JM-22 JM-23 JM-24 (Revised 3/15/63) SGP 0003784 INSTRUCTIONS Johns Manville bags fake the same number as Bestwall bags, except the "P" is omitted and "JM" is added to represent Johns Manville. These bags will have the same construction as that shown under the Bestwall bag number. The bag size and valve size will likewise be the same as the corresponding Bestwall bag. These instructions apply to all Johns Manville bags except the "Special Bag." This item will be used for several different types of products and our plant will specify construction, size, and all pertinent information on the order specification sheet. Bestwall patent numbers are to be printed on these bags. They will be the same as on the corresponding Bestwall bag. The directions for these bags arc not shown separately as are the Bestwall directions. Directions and other copy must be taken from the miniatures. The direction number shown under the Bestwall bag number does not apply. Ink colors are to be as shown on the minioture. Color of outer kraft ply to be the same as miniature. (Revised 7/24/63) Page *JM-1 SGP 0003785 SGP 0003786 BASECOAT NEAT NEAT SGP 0003788 BASECOAT SGP 0003789 SGP 0003790 SGP 0003791 SGP 0003792 SGP 0003793 SGP 0003794 SGP 0003795 GAUGING PLASTER SGP 0003796 SGP 0003797 SGP 0003798 ONHOdlAlOO IAI3J.SAS J.NIOP MinSdAO aillANVIM'SNHOr JO IN T SYSTEM CO M PO UND [T j uizj: jo;s J>2fHeSmSi Z 0 OL <0. 0 z<K IHS' Z Jo 0< -> ")WEJr JOHNS-MANVILLE GYPSUMl JOINT SYSTEM COMPOUND J M 10 5 ' B^g. No. 15 pp^e No SGP 0003799 JO IN T S Y S TE M TAPE AND COMPOUND Bag. 10 5 1 Page No.--J-M 1 61 SGP 0003800 b e d d in g c o m p o u n d B E D D IN G C O M P O U N D JOHNS-MANVILLEGYPS BEDDING COMPOUND JUL 2 0 196? Br.g. i io. J M 10 5 2 J M 17 Pc rr."> No SGP 0003801 *'V ''?' "" "?: '.jdwtegfe dNno'ciiMoo ONiVNiM>ri INnSdAO H~l'TIANVIM`SNHbr r- i#,-- * Ja:jf'vr , - *s sfc'v . ................ v JOHNS-MAN1 :.!-? LAMINATING COMPOUND^ r v-wM. ,^2.i SGP 0003804 SGP 0003805 SGP 0003806 JOHNS-MANVILLE SPECIAL PLASTER UOHNS-MANVILLE GYPSUM r FAST-SET COMPOUND 0z D O5 0 L. U o. "I s 0 z* o Uo 3Z M K< 5<! I- tn < IL i? iii Sj Jih I iti i ll !i 3jif ill! Bag. No. J M 1--lL FageNo___J M -- SGP 0003808 INDEX BARRETT BAGS DESCRIPTION INSTRUCTIONS Fibered Plaster Miniature Unfibered Plaster Miniature Fibered Lite Mix Miniature Unfibered Lite Mix Miniature Gauging Plaster Slow Set Miniature Gauging Plaster Quick Set Miniature Extra Fibered Miniature Machine Application Unfibered Miniature Machine Application Fibered Miniature Special Plaster Miniature PAGE NUMBER BA-1 BA-2 BA-3 BA-4 BA-5 BA-6 BA-7 BA-8 BA-9 BA-10 BA-11 (Revised 12/12/62) SGP 0003809 INDEX BARNETT BAGS DESCRIPTION INSTRUCTIONS Fibered Plaster Unfibered Plaster Fibered Lite Mix Unfibered Lite Mix Gauging Plaster Slow Set Gauging Plaster Quick Set PAGE NUMBER iiiiti * (Rev j :;cl 3/.'v3/6-) SGP 0003810 INSTRUCTIONS Barrett bags take the same number as Bestwall bags, except the "P" is omitted and "BA" is added to represent Barrett. These bags will have the same construction as that shown under the Bestwall bag number. The bag size and valve size will likewise be the same as the corresponding Bestwall bag. Bestwall patent numbers are to be printed on these bags. The/ will be the same as on the corresponding Bestwall bag. The directions for these bags are not shown separately as are the Bestwall directions. Directions and other copy must be obtained from the miniatures. The direction number shown under the Bestwall bag number does not apply. Ink colors are to be as shown on the miniature. Color of outer kraft ply to be same as miniature. (Revised 7/24/63) Page ^BA-l SGP 0003811 SGP 0003812 SGP 0003813 SGP 0003814 SGP 0003815 SGP 0003816 SGP 0003817 SGP 0003818 SGP 0003819 SGP 0003820 3 ^ v i n uwj t i PLASTER SGP 0003821 INDEX WAGNER WAGO BAGS INSTRUCTIONS Laboratory Plaster Miniature Page No. W-1 W-2 (Added 7/24/63) SGP 0003822 INSTRUCTIONS Wagner vVago bags take the same number as Bestwall bags, except the "P" has been omitted and "W" has been added to represent Wagner Wago, These bags will have the same construction as that shown under the Bestwall bag number. The bag size and valve size will be the same as the corresponding Bestwall bag. Bestwall patent numbers are to be printed on these bags. They will be the same as on the corresponding Bestwall bags. The directions for these bags are not shown separately as are the Bestwall directions. Directions and other copy must be taken from the miniatures. The direction number shown under the Bestwall bag number does not apply. Ink colors are to be as shown on the miniature. Color of outer kraft ply to be the same as the miniature. (Added 7/24/63) Page ^ W-l SGP 0003823 SGP 0003824 120 EAST LANCASTER AVENUE ARDMORE, PENNSYLVANIA July 20, 1962 SUBJECT: PIASTER BAG MANUAL Gentlemen: We are enclosing several new miniatures and several revised pages for your Bestwall Plaster Bag Manual. We will list these items below and we request that you immediately add them to the manuals in your possess ion. Wherever the addition replaces an existing item, the existing item should be destroyed. Page 1 - Ink ColorB - green has been added. Page 15B - new miniature covering Wood Fibered Plaster Page 17 - Agricultural GypBum Bags - Bag No. P-552 has been added Page 17C - new miniature covering Agricultural Gypsum Page 29A - new miniature covering Speckling Compound Page JM-2 - revised miniature for Neat Base Coat Fibered Page JM-7 - revised miniature covering Lite Mix Regular Fibered Page JM-17 - revised miniature covering Bedding Compound Page JM-18 - revised miniature covering Topping Compound Page JM-22 - new miniature covering JM Special Plaster Barrett Index Page - revised in that several bags have been added Page BA-8 - new miniature covering Extra Fibered Page BA-9 - new miniature covering Unfibered Page BA-10 - new miniature covering Fibered Very truly yours. BESTWALL GYPSUM COMPANY OJF/gmm Ass't. General Purchasing Agent SGP 0003825 INK COLORS RED is to be exactly the same as Sinclair & Valentine's #740. DARK BLUE is to be exactly the same as Sinclair & Valentine's #912. LIGHT BLUE is to be exactly the same as Sinclair & Valentine's #906. GREEN is to be exactly the same as Sinclair & Valentine's #249-736. (Revised 7/20/62) Page #1 SGP 0003826 AGRICULTURAL GYPSUM BAGS BAG NO P-550 BeBtwall Agricultural Gypsum Bag - Pasted Valve (Stepped End) - Construction 2/40K-2/50K for 100#,'2/40K-1/5QK for 50# - Natural brown color kraft - Patent Number - None - Printed one side - edgeB - top end bottom Dark Blue - Gross weight to be specified on purchase order Direction No. NONE. BAG NO. P-551 Bestwall Agricultural Gypsum (Export) Bag - Pasted Valve (Stepped End) - Construction 1/50K-1/9QAL-1/50K-2/60K - Natural brown color kraft - (90AL to have overall perforations) - Patent Number - None Printed one side - edges - top end bottom Dark Blue - Direction No. NONE . BAG NO. P-992 BeBtwall Agricultural Gypsum Bag - Pasted Valve (Stepped End) - Construction 2/40K-2/50K for 100#, 2/40K-1/50K for 50# - Natural brown color kraft - Patent Number - None - Printed one side - edges bottom Red and Green - printing on rear is less than 28 square incheB in area - Gross weight to be specified on purchase order - Direction No. NONE. (Revised 7/20/62) Page #17 SGP 0003828