Document rMXbybLrroJo58qOaGyanY4V

EMPIRE AND STANDARD TYPES 1-G-E AND 1-G FOR STEAM AND HOT WATER PLAINTIFF'S EXHIBIT ASI-788 American q ^ismdavd Radiator ^ CORPORATION 23242 EMPIRE aid NTH III IIII GAS KOILERS FOR EFFICIENCY AND BEAUTY If you seek both beauty and efficiency, the Empire Gas Boiler (see front cover) is perfect. Its rich, colorful Jacket is finished in Canyon Two-Tone Red, suede texture. It is so handsome and beautiful it blends with the finest modern basement and appointments. All controls are concealed beneath the smart exterior, out of sight, out of the way, but available in an instant when necessary. STANDARD BOILER TYPE 1-G WHERE APPEARANCE IS SECONDARY If you have a separate boiler room, or if appearances are unimportant I he Standard Gas Boiler (see illustration above) will fill all requirements. For it is identical with the Empire except it does not include the all-over Canyon Two-lone Red Jacket, and I lie controls are on the outside of the boiler. American Look for this Distinctive Name Plate SCIENTIFIC DESIGN American Gas Boilers have been designed by Gas heating experts. They embody the latest developments in the field. Specially designed for Gas operation only they get all the good out of every cubic foot of gas. Safe, sure and silent in operation they are designed for a lifetime of trouble-free, economical service. THERMOTOR THROTTLING VALVE This special Valve is controlled by the thermostat. It gradually reduces or increases gas How to the burner to keep room temperature just right. It keeps gas con-iimption to a minimum, and combined with the thermostat eliminates the need for manual work to keep constant comfort in the house. CAREFREE COMFORT Both the Empire and Standard Gas Boilers offer you heating that's so automatic you don't even have to order fuel! The thermostat, the special Thermotor Throttling Valve and other quality controls guard the temperature you want with precision accuracy. Glean, quiet and odorles- in operation, these Boilers have brought the blessin - ot automatic heating comfort to thousands of homes , won the lasting approval of homeowners. HEAVY INSULATION A thick layer of Air-Cell Asbestos Insulation preventexcess heat loss into the basement. This also aids in re ducing operating costs and keeps the jacket cooler. EASY TIME PAYMENTS If you are modernizing, it is not necessary to pay for a new Empire or Standard Gas Boiler all at once. Easy time pay ments can be quickly and simply arranged. They can he planned so that monthly payments will be fully in accord with your budget -- no matter how big or small. SHORT FORM SPECIFICATIONS (For All Boilers) In general the following form will be found adequate "Furnish and install according to manufacturer's instruc tions. where shown on the plans a Type I-G-? Gnerican Standard (or Empire) Steam (or Water) Gas Boiler with an A.G.A. output rating of sq. ft. of radiation. The boiler shall be manufactured by the American Radiator A Standard Sanitary Corporation and shall be completelv equipped with Type 10-MT Equipment consist ing of (list items of equipment as indicated on opposite page This may be supplemented with paragraphs governing installation of gas supply, piping, connections, test-, etc., as required. 23243 EMPIRE BOILER CONSTRUCTION FEATURES l. Jacket--handsomely finished in Canyon Two- 1'oiie Med -- suede finish new. 2 Stkxm Flow --a correctly and specially designed steam supply line pipe fitting 3 Thick Vaiikstos \m-Cri.L iNstt.vTios effect i v el y pro* outs excess heat toss from boiler. 4 Low Wxter Cit-Oef -- on steam boiler only Completely shuts off gas supply to main burners if water line reaches a low point ."> Tmkrmotor THRoTTi.i"si# Y y l v e-- operated from the room thermostat Completely shuts off supply of gas to main burners when desired room temperature has been obtained Ml control functions centered in one valve. k lb rot t ling valve cm bod y mg mecha meal limit control ^ 2 3 4 O S T l. 1M PllCSs 1 PE OR W XTEII Tl \1 IT l< V H ill Hi:oi i iTiov --- controls supply of ga=> to burners according In predetermined steam pressure or water temperature G vs Si puli Line-- ample si/e. permits unrestricted supply of gas Gas Pressure Gov ernor mcluded. mounted outside jacket at rear 8 Burner Gock --specially designed to permit smooth flow of gas with minimum friction 0. rurnnusTvTto Pilot -- protect-id from moisture or dirt Keeps gus supply v alv e close,| unless pilot is burning 5 0 y 18 17 ('.utawav I tell' 10 (Jetft Burners -- raised drilled ports Blue llnme burner. Quiet in operation. I I Cue xn-Out Openi.no -- provides easy nrcess fur cleaning flue surfaces of sections I- ^ xti- r Column -- on steam boilers onK Vrtistically framed within jacket giving pro tection against breakage and adding to the beauty of the gas boiler. 18 M ft\i.-to-\li:t.xi. Joint ground, gas- tight. .No cement or putty used patented pin typecast iron section The most effective type of cast iron heat-absorbing surface Hapidlv and ellicientlv absorbs the heal from the rising columns of hot gases, transferring heat in u a ter w it hm boiler 11 f.OMI'lll Ml I'll E>s| ni X M> \ X. I I M I r U r. | oii'l earn boiler (>n w a t or boiler cum Inna t mn altitude gauge and thermometer located here l.. Distimtivi N'xmk Pi.xti - "VMI-.H- IC\N`\ the best known name in heating [f>. Pop Su'fctTi \ vlv i -- A S \t K vlandard Fully enclosed in jacket. 17. Drxlt Hoon -- fully enclosed \cid-prouf vitreous enamel on AH.MCO iron. Prevents either excessive drafts or down-drafts from affecting proper combustion. 18 C xnopx --acid-proof vitreous enamel on V R MCO iron set in put t y - tilled groov e fornnng gas-tight joint. STANDARD BOILER CONSTRUCTION FEATURES 1 (Avon ---acid-proof vitreous enamel on \RMC0 iron, set in putty-tilled groove form ing perfect gas-tight joint 2 Compou.no Presslre xno \ V l t. I m GxIOK -Steam: On water boiler, combination aititude gauge and thermometer located here l Stkxm (Junvkction -- leads from steam d'lme of boiler to diaphragm of main throttling valve i Resettinc Low W iter Ci t-Okp com pletely shuts off supply <>f gas to main burners if the water line on steam boiler reaches a low point a G vs \ si.i i --electrically operated from rourn thermostat Steam Pressure or Water Temperature throttles gas flow to maintain required conditions I pjier limit and manual control also embodied in same valve h Gxs Pressi re Governor - maintains gas pressure at a lixed maximum. 7 1.1 o Si piu.v I.ink -- am|de si/e. provides iiuri`strutted supply of gas 8 y r k v m Dui'hru, m --steam from dome actuates diaphragm, throttling gas when de sired steam pressure is reached, ('u water boilers, we furnish at this point an accurate water temperature control device which is readily adjustable and similarly throttles the gas flow when the water in the boiler reaches the desired temperature u iji ii r Mi hvkk' -- raised drilled ports Blue flame, it rno'phcrie type, quiet in ..per- i t ion Cutairay ] tew I o Thermostatic Pi lot - Operates t her motor valve mechanically, keeping this valve closed unless pilot is burning properly 11 Ventiri Mixer Tibi induces proper velocity to gas and primary air. and obtain* the correct mixtore of gas and air 12 III rner fo(K specially de-igned n- permit smooth flow of gas with minimum fricl ion 18 Jukkt Insm.vtion heavy ashe.sios air cell effectively prevents excess heat loss from boiler II J u.kkt baked enamel mi both side* Black enamel trimmings la t .1.1. xnoi T t Il'FNtNi. prov ides easy acre** for cleaning flue *urfaces of sections I h P xtuntmi PiNTin t\ * r Iron Si:i tion t he ini ist elfeeti \ i1 t y p<' of <;a*| iron licat - absorb tug surface Bapidly and fliciently absorb* the heat from the rising columns of hot gas.'* and transfers (bis heat to the water within 17 M i:t \ i.-tii-M et xl Joint - ground, g.i*t igh t N o . emerit or putty used 18 I 'up S x i-i n I i i.v i - \ > M K st,i adaru Pi Diiut IIoiiii .u id-proof v it rrotis enamel ori \B Ml < iron Prevent* either exce"|\. drafts .,r down-drafts from .iffeetuig proper < omlui'f ion pv\ir i'.tji.ipmi;n t includes nib following S T I1. \ M I'lmrui. >l nr Thrntili tig \ .live with Thermo-Pi lot 7 oh- V S i , Steam Pressure Regulalor, Be.se 111 ng low Water < u I -t >fF <>2<p . (ins Pres*ure7< io \ ernor t'onipou r.d steam Gauge. Pop Safet y Vnl vo; Boiler Drain ami Pilot < irk , (nsula t cd T.nainelod J arkr t , \ 11 ....... .... I .na moled Draft I )l verier W \ TKH Therm >tor Ihrotlliog Valve wilh Thermo-Pilot <ubh-\W'i Water Tern p<;rat ore Bcgulator. tins Pressure (iovernor Combination Mntude (..urge and 1 her ui one ter, Boiler Drain and Pilot Cocks. Insulated bn. uncled Jacket, \ itreoiis bnameled Draft Diverter Note l he 5h*>- V 1 her motor \ a! vc w i t h Transformer is elect rieul I v oi .era led by roem t her mo* t a l T or use w it h any 2-w ire 'Tlierrnosi at or an v P w ire Series 111, Therm. -la l ' 11 h or .vi t hou t cloek > for a u lorn a tic rootn temper a tnre regulation The .7'ih- V a Iso meiud.is I hernm- Pilot, l hrol 11 mg ami mechanical upper limit eon t ml 23244 RATINGS AND DIMENSIONS - STEAM AND WATER EMPIRE BOILER TYPE I-G-E lli.ll.T 1-G- t-hJ 1-G- 3-E i-G- 6-I-; i-o- :-k l-G- 8-E 1-G- 9-E I-G-10-E GA s INLET - FLOOR LINE \ (. \ Steam RaMnn S., Kt 610 > . > 910 110.', 1270 l 1.33 1000 "'ll ppiif- 1 nstalled MadiaO-m S., Kt ion 313 027 713 r>9 `>78 I0Q7 \g v Mating S.) Kt 00 1210 i:>oo L 77<> 2030 2300 2)00 ' ''II S., Kt i:i> Htu 0 13 820 1000 1 100 1373 1307 1 733 1 nsl ailed S,, Kt Jim 10 H 182 015 730 803 1030 1173 1310 1 hum ' ' Finn lo 32 18 36 20 10 22 14 21 18 26 52 28 36 0 7 8 8 8 9 0 Numhrr & Si?e lapping Kin Rplurii 1 >4 1'4 ll4 lh2-4 l'. 2 2 2-4 2-4 2-1 j 2-4 2-1 2-1 2-4 2-t 2-1 2-4 2-1 2-1 2-1 STANDARD BOILER TYPE 1-G 41 Km.I.t V. - [T jRN \ r. \ Steam Hating >q Kt 1 *Srj pphps r MStallerl Harlmtinii S' | Fl 'll \G \ \\ .Her Haling >M I ( 1 1 "''U iqilies 1 nslaOed M Kt 1 `.It lOu M Ki Min 1. \ ** M 4 0CT_=.j_ 1) I ham KI..... 1 Gas <'nriueeti >r Number A Size 1 appi up Kliu Hefurii Mi- 1 Mi- 3 l-(i- o Mi- 7 610 ... 010 1105 100 33 627 713 080 1210 1300 177o 0 13 820 |000 1 ion 182 (.17 730 803 10 33 30! f, 23 30 33 27 13 31 17 31 () 7 8 8 I 14 1 1 14 1 `J 21 21 21 2-1 2-1 2- 1 21 2-1 M 1- 8 Mi- 0 1 -l MO l-G-ll 1270 l 133 1000 1763 830 078 1007 1217 2030 23oo 23oo 2820 13::'. !3o 7 1733 CM3 1030 1 173 1310 1 130 33 31 33 30 33 3 6 13 30 38 Mi IT 63 30 8 0 0 10 11 , I > 2 21 2-1 21 2-1 2-1 2-1 2-1 2-1 M.iImirs lis|.*< miller "Supplii S 1 MS) il Ill'll ' include a miii ,<0le .llo.4.,M. e o.r mirm.il piping and pit kup iTi s rating I s On.vsn < It pi I led < > n (lie ),.,. i. if ! TO Mtu am -<"> nlii (i>T si|ii.ire hint jicr h<>ur missti>n For u.<ter limlrr- mil J | 1) Mill "T si) l|. ire Fi.mI per It'ii r fur sie. m 1 > >i I.T- \.,le \| dimensions ar Ill III ties ! <T sii .mi IkuIit \\ aO*r Omler is 1 shorter yarm \<s -f>?0 ISM h II Graph.- American q ^tafldavd Radiator ^ ^aititarg Hew^oik CORPORATION ^PmbuAqh 23245 Printed in I ^ \