Document rKr78b3ogoE7q6jkjoddxnLJ

American Society of Heating and Ventilating Engineers Guide, 1935" ceiling of the equipment room, or the inner walls of the ducts, with sounn absorptive materials. The: inteennssitityyI. of a continuous sound in a room' '/ = -- PS' where E = the rate of emission of the noise source = P SK (The intensities of noises enter' the room times the areas through which they enter.) In8 a = the total amount of absorption supplied by the boundaries and contents of th room. ' ' '. ' e =' ai.Si 4- aj^s T atSt .......... , where Si, St, Si.............. are the areas of the boundary materials for the room, and a,, a2, on,.. . . . . are the corresponding coefficients of absorption. Hence, by increasing tenfold the absorptivity of the boundaries of a room it is possible to reduce tenfold the average intensity of sound in the room; that is, the intensity level would be reduced 10 db. Thus it is possible to compute the noise level in the room if the intensity of noises entering the room or generated in it are known.- . It will be seen that the noise intensity reduction is dependent upon the amount of sound absorption in the room, and that the first units of absorp tion are more effective than succeeding units. In general, the room noise level wili be from 10 to 20 db lower than the air' inlet or outlet noise intensity, the 10 db being in the case of bare rooms having large venti lating cirair conditioning openings in relation to their size, and the 20 db in the case of rooms having large amounts of absorptive material with small openings. In some cases, the noise level reduction may run up to as much as 30 db, but then the higher sound intensity adjacent to; the openings tends to nullify the effects of the extra reduction. Where these openings are large, the local effect on the noise intensity extends some. distance from the opening; for instance, a four-square-feet opening might have a local effect within ten feet, while a one-half-square-foot opening would have a local effect within only five feet. The coefficients of sound-absorption for-a-number of standard absorp tive materials used, or suitable for use, in equipment rooms are given in Table 2. ; Coefficients are given for frequencies of 128, 512, and 2048 cycles. Where the frequency of the noise is not known, the values for ,512 or 128 cycles are usually used. INSULATION OF AIR BORNE SOUND The transmission of air-borne sounds through rigid partitions is accom plished primarily by the diaphragm-like vibrations of the partition. The weight per square foot of the wall is the determining factor, and the insulation value of a wall, in terms of the.transmission loss in decibels, is proportional to the logarithm of the weight per square foot. Other factors, such as size, stiffness, composition, manner of mounting, and the use of multiple structures separated by air spaces or flexible connectors, contribute to the effective insulation. If the coefficients of sound trans mission of different types of structures and the noise intensity in the space adjoining a room are known, it is possible to calculate the noise intensity in a room by the use of formula 1 and the following formula: ...................... P = /"T (3) 304 Chapter 18--Sound Control Table 2. Coefficients of Sound Absorption3 (Inches) -^ustex 60, spray painted.^ Ac0US;Celotex, Single B. Sti-Celotex, Triple B.. jujouSc Flexfelt--......................... Akoustolith A, Tile---..... Brick wall, unpainted..............-..... Called--.--- r Cdrkoustic, Type C.........-.................... i Ye VA ....... l Vi l 18 1 m Ste Aroultlie, Type 44:..--....... - -...... with three coats lacquer..... ................. Jja^Justic Plaster, stippled to depth of in.. Masonite--. pnlaanstiedri eb/ypks_u_m__ on__h__ollo,w tile,--, Plaster, gypsum, scratch and brown coats on metal lath on w<x>d studs..... .............. plaster, lime, sand finish, on metal lath.......... Poured'concrete, unpainted..---- Rockoustile----------- ------............. -.............. -..... Sabinite-.----------....... v.................... ...... - SanatousticTiIe ...................... Stuccoustic Plaster, Type.XB...... Transite Tile--...................................................... Trutone Tile...........................-......... -................. Wood sheathing, pine:..... ->----------- ................. Wood, varnished--................... -................ ---- m 3A y-t 7Ae X i lA H l We Coefficients of Sound Absorption 128 Cyclfss 512 Cycles 2048 Cycles 0.16 0.11 .0.20 0.27 0.21 0.14 0.024 0.23 0.08 0.035 0.26 0.35 ; 0.13 0.18 . 0.013 0.51 0.45 0.75 0.56 0.66 0:29 0.48 0.031 0.72 0.61 0.027 0.50 0.43 0.31 0.32 0.020 0.72 0.68 0.67 0.68 0.69 0:37 0.83 0.049 0.71 0.64 0.020 0.61 0.45 0.58 0.33 0.040 0.020 0.038 0:010 0.18 6.19 0.29 0.19 0.31 0.098 0.05 0.040 0.060 0.016 0.57 : 0.34 ,0.79 0.59 0.81 0.57 0.10 : 0.03 0.058 ' 01043 0.023 0.72 0.49 0.74' 0.72 0.72 0.64 0.082 0.03 Architectural Acoustics, by V. O. Knudsen, pp. 219, 220. 240-251. where ' P = noise intensity in space adjacent to room. t = coefficient of sound transmission. ' ,\ V ..V , Coefficients of sound transmission for some common .walls are shown in Table 3. Example 1. Suppose the brick wall between an equipment room and an adjacent auditorium has an area of 200 sq ft arid a coefficient of sound of 0.00001. (see.Table 3); that the auditorium contains 2000 sabines* of absorption; arid that the noise level in, the equipment room is 70 db above zero level. ,-v /ti 70 -- 0 = 10 logio -iyo- (from Forrnula 1) . j - 10' I0 P_ = 107 X 0.00001 = 100 (from Formula 3) Io 4- = 100 X = 10 (from Formula 2) io JUUU ' *A sabine is 1 sq ft of totally absorptive surface. 305 jfiifc..