PPG INDUSTRIES CHEMICAL DIVISION LAKE CHARLES, LOUISIANA
I
NUMBER ONE ETHYLENE BICHLORIDE PLANT OPERATING MANUAL
Sub j ect c ?rc tactiivve Order 14th Judicial DIlssttrrict Court
Book No.
MARCH, 1967
SL 008555
CONFIDENTIAL: Subject to Protective Order q 14th Judicial District Court
No. 31-1145
Page
c. Steam Supply d. Cooling Tower System 4. Refrigeration System 5. Stack Seal 6. Ethylene Supply System 7. Chlorine Supply System 8. Reactor 9. HCI Stripper 10. Distillation Column 11. Rework Kettle 12. Bottoms Purification 13. Pre-Start-Up Procedures
5-6 5-7 5-8 5-9 5-9 5-9 5-11 5-12 5-13 5-15 5-16 5-17
VI. SHUT-DOWN PROCEDURES A. Overall Shut-Down Procedures B. Detailed Equipment Shut-Down Procedure 1. Ethylene System 2. Chlorine System 3. Reactor 4. HCI Stripper 5. Distillation Column 6. Vent Gas Refrigeration System 7. Utilities a. Electrical System b. Steam Supply 8. Cooling Tower System 9. Instrument Air System 10. Stack Seal 11. Flasher C. Emergency Shut-Down of Equipment 1. Reactor 2. Stripper 3. Still 4. Loss of Refrigeration 5. Loss of Cool ing Water 6. Loss of Steam Supply 7. Loss of Instrument Air 8. Loss of Electricity 9. Fire, Explosion, Line Rupture
6-1 6-1 6-2 6-2 -2 6-3 6-3 6-3 6-4 6-4 6-4 6-5 6-5 6-5 6-5 6-5 6-6 6-6 6-6 6-6 6-7 6-7 6-7 6-7 6-7 6-8
VII. ANALYTICAL A, Sample Points B. Control Samples 1. Sampling Schedule 2. Liquid Samples 3. Analytical Methods
SL 008558
7_1 7-1 7-1 7-1 7-1 7-1
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
C. Laboratory Samples 1. Sampling Schedule 2. Sampling Procedures
D. Process Chromatograph Table 7.1; Sample Points Table 7.2s Schedule of Control Test Table 7.3; Schedule of Laboratory Test
E. Analytical Control Test Method M-l, Water in EDC Method M-2, Iron in EDC Method M-3, Orsat Analysis of Vent Gas for HCl, C2H4 and Inerts(No Cl2 Present) Method M-3A, Orsat Analysis of Vent Gas for HCl, C2H4and Cl2 Method M-3B, Determination of Free Chlorine in Vent Gas Method M-3C, Orsat Analysis for HCl, C02, 02 and C2H4 In Vent Gas Method M-4, Acidity as HClMethod M-5, FeC^ in Reactor Method M-6, C2H4 Moisture by DewPoint Method M-6A, C2H4 Purity Method M-311, Alkalinity Method M-312, Ca-Mg as CaO Method M-313, Chloride Method M-314A, Chlorine Method M-315, Chromate Method M-315A, Betz 107 Method M-316, Phosphate Method M-317, Silicone Method M-318, pH by Meter Method M-318A, pH by Slide Comparator
VIII. PRODUCT STORAGE
IX. CATALYST SOLUTION A. General B. Preparation C. Addition
V Dumpu4G
X!. SAFETY FOR THE EDC AREA A. General B. Definitions C. ChemicalsIn the EDC Area
SL 008559
Poge
7-1 7-1 7-2 7-3 7-4 7-6 7-7 7-8 7-9 7-11
7-14
7-16
7-19
7-21 7-23 7-25 7-26 7-27 7-28 7-29 7-30 7-31 7-32 7-33 7-35 7-36 7-37 7-38
8-1
9-1 9-1 9-1 9-1 lo-1 11-1 11-1 11-1 11-1
fV CPU l L
PAGE NUMBERING SYSTEM This manual is designed to permit revision and additions without disturbing the order of page numbers or the figure designations of illustra tions and tables other than in the particular section affected by the changes. This is accomplished by using a combination of two numbers, the first being the section number while the second represents a page, illus tration or table in the section. Tlius, page 10-5 represents Page 5, Sec tion X; Figure 3.5 is Figure 5 of Section III; and Table 8.5 is fable 5 of Section VIII.
SL 008561
COMPOUND ABBREVIATIONS
coNF:av.yj?ij\L: Subject to Frotc" hive Order
Of 14th Judicial District Court NO. 91-1145
1-1
Abbreviation
Name
Formula
Atm. B. P.,
n2 Nitrogen (Light) n2 -345.75
co2
Carbon Dioxide (Light)
co2
-109.30
2
Oxygen (Light)
2 -297.40
CO
Carbon Monoxide (Light)
CO
-313.60
h2 Hydrogen (Light) h2 -422.86
ch4 c2ha c2h6 HC1
Methane (Light) Ethylene (Light) Ethane (Light) Hydrogen Chloride (Light)
ch4
c2h4 c2h6 HC1
-258.52 -154.68 -127.53 -121.09
Cl2 Chlorine (Light) Cl2 -29.29
EDC
1,2-Dichloroethane
C2H4C12
182.25
(Ethylene Dichloride)
1,1,2-TCE
1, L ,2-Trichloroethane (Heavy)
c2h3ci3
236.79
Unsym TeCE
1 i. 1,2-Tetrachloroethane (Heavy)
c2h2ci4
264.2-266.0
Sytn TeCE
11,2,2-Tetrachloroethane (Heavy)
c2h2c14
295.16
Tars or HvCl
Any Heavy Chlorinated Hydrocarbons
-
-
Note; "Heavy" Indicates compounds having higher boiling points than EDC, "Light" indicates compounds having lower boiling points than EDC.
SL 008562
II. INTRODUCTION
CONFIDENTIAL*. Subiect to Protective Or^er Of 14th Judicial District Court
No. 91-1145
2-1
This operating manual has been assembled with the fol! in mind:
1. To be a training guide for the operators in learning the EDC plant operations.
2. To serve as a ready reference for operating personnel during their stay at the EDC plant.
1. To provide a standard approach for operating the plant from shi ft. to sh l ft.
4. To serve as a place where current data, facts, inloimation, operating procedures, etc., related Lo the EDC plant are compiled.
As operating experience is gained, it is expected that some of the Standard Operating procedures (SOP's) outlined in this manual wil' he
altered. Please feel tree to suggest changes that will aid in keeping this manual up-to-date.
This manual is the property of the Chemical. Division of PPG Industries and may be recalled at any time. You are personally responsible for the safe keeping of this particular manual which has been numbered and charged to you.
SL 008563
CONFIDENT! A I.: Subject to Protective Order o 14th Judicial District Court
No, 91-1145
3-1
III. GENERAL DESCRIPTION OF EDC PROCESS
A. Uses of EDC
The major uses of EDC generally fall into these categories:
1. It serves as a raw material to produce vinyl chloride.
2. It is a raw material for production of chlorinated organic com pounds such as Tri-Ethane, perchloroethylene and trichloroethylene.
3. It is used as an additive in corapounding tetraethyllead fluid.
4. It is a degreasing solvent, extraction solvent, dewaxing solvent, and fumigant agent.
The major use of EDC is as a raw material in producing vinyl chloride monomer from which the enormous line of vinyl plastics is made.
A large portion of the EDC produced by PPG in Lake Charles is captively used as a raw material for producing other chlorinated organics.
EDC is used in compounding tetraethyllead fluid (1,'EF). The commercial! important TEC blend consists of various amounts of tetraethyllead, ethylene dichloride, ethylene dibromide, kerosene, dye, and an inhibitor. EDC has not gained much favor as a degreaser or dry cleaning solvent because of its flamma bility. However, it is used in vapor phase degreasing of metal parts. Other incidental uses of EDC include extraction solvents for fats and oils, caffeine, cottonseed oils, etc. It has been employed in dewaxing of oil products, de oiling of petroleum waxes, and as a component in fumigant compounding.
B. Process Description:
Process flow sheets for the operations to be described in this sec tion are given on pages 3-6 and 3-7.
1. Reactor: Ethylene dichloride is produced by the reaction of one mole of chlorine with a mole of ethylene in a volume of liquid ethylene di chloride containing ferric or iron chloride (FeC^) as a catalyst. This is an addition reaction; i.e., chlorine adds chemically to ethylene to produce EDC as shown in the following equation:
HH C=C HH Ethylene
28.052
+ Cl,,
FeCU
Catalyst
Chlorine
70.914
HH
v HC- CH Cl Cl
Ethylene Dichloride (EDC) 98.966
All of the ethylene and chlorine is utilised to produce the product and essentially no by-products are formed.
SL 008564
CONFIDE'lTIM-s
Subject to Protective Order of 14th Judicial District Court
No. 91-1145
Unfortunately, some undesirable secondary reactions do occur. The more prevalent of these is the substitution reaction in which EDC and chlorine react to produce trichloroethane and hydrogen chloride, as follows;
Mol. Wt.
HH HC - CH
Cl Cl EDC
+ Cl-> Chlorine
98.966
70.914
HH Cl C - C H Cl Cl 1,1,2-Trichloro-
ethane (TCE) 133.415
+ HC1
Hydrogen Chloride
36.465
The TCE can undergo further substitutive chlorination to produce
tetrachloroethanes (TeCE):
HH Cl C - C H
Cl Cl
+ Cl2 _____ Chlorine
HH Cl C - C Cl
Cl Cl
+ HC1 Hydrogen
TCE
Sym. TeCE
Chloride
Mol. Wt.
133.415
70.914
167.864
36.465
Actually the FeCl3 is not a true catalyst in this operation. In reality, it is used to depress or inhibit the secondary substitution reactions.
The light products from secondary reactions, the impurities in the incoming gas streams, and unreacted ethylene and chlorine make up the vent gases from the unit.
The reaction of ethylene and chlorine is exothermic, that is, it gives off heat. Theoretically, the heat liberated from this reaction is more than six times the heat required to vaporize one mole of ethylene dichloride. The heat of reaction at 25 C is 50.4 Kcal/gm. mole while the latent heat of evaporation of EDC at its boiling point is 7.7 Kcal/gm. mole. It is necessary to cool the liquid EDC in the reactor, otherwise, the reactor would boil dry. Cooling is accomplished by condensing the vaporized EDC and returning a stream of liquid EDC to the reactor to maintain the level. In such an operation, known as a boiling reactor, the cooling is accomplished at the condenser using cool ing water.
In the pilot plant for every 4.5 moles of EDC vaporized, 3.5 moles of cooled EDC were, returned to the reactor. This is defined as &ie reflux ratio of 3.5/1. Theoretically, in this plant, with smaller heat losses for every 6.5 moles of EDC vaporized and condensed, 5.5 will be returned to the reactor (reflux ratio 5.5/1).
The vaporized ethylene dichloride plus the by-products and impuri ties leave the top of the reactors in the gaseous form, and go to the reactor condensers. The condensed liquid flows down through a stand leg to the reactor gas separator. The major part of this stream is refluxed back to the reactors to keep the levels constant. The reflux flows are automatically controlled by level controls on the reactors. The condensed liquid that is not required for reactor level control goes to one of two places; to the stripper as feed or to the Per/Tri plant as feed.
SL 008565
COD FI D-D ?T17*I.: Subject to Protective order of 14th Judicial District Court
No. 91-1145
3-3
The vapors from the reactor condensers, the reactor gas separator, the stripper condensers and the stripper gas separator are vented through the separator condensers. The liquid from the separator condensers flows back to the reactor gas separator through a stand leg.
The vent gas from the separator condensers goes to the vent con denser to recover the last traces of EDC. The condensed liquid is returned to the reactor gas separator.
The noncondensable gases from the vent condenser flow to the stack seal where they are scurbbed with water, then discharged to the atmos phere through the vent pipe mounted on the side of the still. The water scrubbing removes most of the. HC1 that is formed as a by-product.
The pressure drop through the vent system dictates the operating pressure on the reactor; atmospheric plus the pressure drop through this system. In a given size system, the more vent gases that flow the higher the back pressure on the reactors.
2. Stripper: The EDC liquor from the reactor gas separator that is not fed back to the reactors for level control or to the Per-Tri plant as feed flows as feed to the stripper. This feed rate is regulated by the level con trol in the reactor gas separator.
The primary function of the stripper is to separate the low boil ing components (lights) from the EDC. These light components are primarily HC1, some unreacted ethylene and impurities that enter the reactor in the feed streams.
The liquid flow from the reactor gas separator enters the top of the packed stripper. The liquid flows down through the packing counter-current to the upward flow of hot vapors containing light products and EDC. The stripping action removes the low boiling components from the EDC before it reaches the bottom of the stripper. Product is removed through an overflow and stand leg into the EDC process crude tank.
To obtain the most efficient operation of the stripper, a certain amount of EDC is refluxed. In the pilot plant operation, 1.5 moles of EDC was vaporized overhead for every mole of product that was taken from the bottom of the stripper. The EDC is vaporized by applying steam to a reboiler on the side of the stripper. The steam flow to the reboiler is regulated to produce the desired reflux ratio.
The light components plus the vaporized EDC leave the top of the stripper and pass to the stripper condensers. The condensed EDC flows through a stand leg into the stripper gas separator. This stream constitutes the stripper reflux. The reflux flow to the stripper is controlled by the level control in the stripper gas separator and is regulated by the quantity of steam that is fed to the stripper reboiler. This column is essentially on total reflux of EDC; HC1 and lights being the only materials vented overhead.
SL 008566
CONFIDENTIAL: Subject to Prov. tsc Li. ve 0f<3er of 14th Judicial District Courts
No. 91-1145 The. noncondensable from the stripper condensers are vented to the separator condensers where they are mixed with the noncondensables from the re.aetor system.
3. EDC Still: The liquid in the process crude tank is EDC with a purity ot 97 to 99%; however, it still contains the heavier chlorinated organic compounds. These impurities are separated from the finished product in the distillation column or what is commonly called a still.
The liquid from the crude tank is pumped to the feed tray of the still. This flow is set to maintain a constant desired feed rate to the still.
The Number one and Number two EDC plants are tied together such that EDC from either plant crude tank can be fed to the other plant still.
The liquid feed flows downward through the column counter-current to ethylene dichloride vapors. The heavy chlorinated organic compounds with high boiling points flow down the column to the re.boiler. Here they accumulate and are periodically withdrawn and sent to the still bottoms storage tank.
Liquid in the bottom of the still is vaporized in a thermosiphon reboiler. This produces the upward flew of EDC vapors which become increasingly pure toward the top of the still. These vapors leave the top of the still and are condensed. The condensed liquid drains to the still reflux drum through a stand leg. Any noncondensables are vented through the stack seal. The pres sure drop through the stack system determines the operating pressure of the still over and above the slight nitrogen and pressure imposed on the condenser.
To obtain the maximum efficiency and separation in the still, a part ot the condensed overhead product is circulated back to the top of the still as reflux. The ratio of EDC returned to the still as reflux over the EDC removed as product is termed the still reflux ratio. This reflux ratio should be approximately 1:1. The reflux flow is set at a constant desired rate.
The excess condensed product from the still reflux drum is pumped through the product cooler to storage. The product flow rate is controlled by the still reflux drum liquid level.
The still bottoms are pumped periodically to the still bottom storage tank.
The product storage tanks are padded with nitrogen to eliminate the mixing of EDC vapors with air to form an' explosive mixture. The pad is maintained at about 3 inches water pressure at the top of the tanks. The pad system also prevents water contamination of the stored EDC by wet air.
SL 008567
Subject t.o b.o^;c'.ive Order of 14th Judicial District Court
No. 91-1145
3-5
4. Flasher: This system is designed to remove tar and carbon solids from the EDC still bottoms so that these bottoms (primarily TCE) may be used as feed to the Per-Tri plant. A thermosiphon reboiler will vaporize the lighter boiling compounds. The overhead stream, consisting primarily of TCE and EDC, will be condensed in^the flasher condenser and will enter the flasher condensate tank. From this tank the bottoms stream is pumped Co the bottoms storage tank, this tank is the reactor dump tank. From the dump tank the bottoms are sent to the Per-Tri plant.
SL 008568
cr.:-:F;ur^71.\L: Subject to j'rc:' .ciWo harder Of 14 th jy'tj'.:' Di-;crict Court
Ko. 9 i -1 x -i 5
4-1
IV. DETAILED EQUIPMENT DESCRIPTION
A. Process Equipment
1. Ethylene Feed System: Gaseous ethylene at 600 to 900 psig is supplied by a 6-inch pipeline from the Petroleum Chemicals, Inc., plant approximately 5 miles west southwest of our plant. At a junction point near Louisiana Supply is the 4-inch take-off serving PCI's metering station, situated in the northwest corner of the EDC area. No PPG facilities are to be located within 75 feet of the metering station without prior written consent from PCI. Maintenance of the station and the line feeding it is PCI's responsibility. In case of trouble in the station notify the Shift Engineer. The station is provided by PPG with a 1-inch instrument air line, 2-inch steam line and necessary power for instruments and lighting.
Upon entering the station, the ethylene flows through a filter charged with activated alumina to remove scale and oil.
From the filter the ethylene passes through one or both of two tube-type steam heated exchangers which are arranged in series. The exchangers provide 70F gas and eliminate icing in the first stage of pres sure reduction. The ethylene, temperature at the exchanger discharge is controlled and monitored; steam flow to the exchanger is controlled fay the temperature. The temperature recorder is located in the sheltered meter house. PPG has agreed to change the temperature chart daily; it is to be sent to PCI via our Record Department.
From the exchangers the ethylene goes to the first stage re ducing station which brings the pressure down to 300 psig.
The ethylere then proceeds through two G.E. mass flow meters arranged in series. These meters are digital integrators which read directly in pounds. While either or both meters can be bypassed, normally both are in service. When the temperature chart is changed these integrators are to be read and their values recorded and forwarded to the Record Department for transmittal to PCI.
Leaving the mass flow metering installation, the ethylene enters the second stage reducing station which lowers the pressure to 165 psig. It is then metered by a G.E. mass flow meter owned by PPG. This integrator reading is to be recorded when the ethylene temperature charts are changed.
The mass flow meters are measuring the total ethylene consumption of Production Area B, not just the ethylene consumed by the EDC units.
Leaving the PPG metering station the ethylene flows through a b-inch line to the EDC pressure reducing station. The ethylene flows to the two EDC units are split upstream of the station. Separate pressure reducing station are used for the units. The pressure is lowered to 45 psig and is continuously recorded and controlled in the control room. High and low pressure alarms are provided on both the upstream and downstream sides of the reducing station.
SL 008569
roi-F ;d FTTI'.b:
of
subject v-; 14th Judic
1^.1
-.rtivs Order i\ i.ict Court
No. 91-1145
4-2
The pressure reducing station consist of two pressure control valves arranged for parallel flow. The smaller of the valves will regulate the downstream pressure and the larger valve will be closed at the lower flow rates. The larger valve will open and control the downstream pressure when the flow rate becomes larger than the small valve can handle; the small valve is completely open at this time.
The ethylene stream splits downstream of the pressure reducing station. From this point the feed systems to the two reactors are separate. Each stream passes through a recording flow controller and a loop seal before entering the reactors through the spargers. The temperature of the ethylene at the metering orifice is continuously recorded along with the control pres sure on a strip chart in the control room. This chart and the ethylene flow chart should be torn daily and sent to the Record Department for ethylene con sumption calculations.
2. Chlorine Feed System: The No. 1 EDC plant gets its chlorine feed from the liquefaction area through two systems. One- feed system supplies liquid chlorine while the other supplies chlorine cell gas. The plant feed will be either all liquid chlorine or a combination of liquid chlorine and cell gas.
Liquid chlorine is piped to Production Area B from the No. 7 and 8 chlorine scale tanks in the liquefaction area. The liquefaction lead operator is responsible for switching the chlorine feed from one scale tank to another to assure a continuous supply. When a switch is made a. slight change in supply pressure may be experienced. The liquefaction department will notify the EDC plant when a switch is going to be made.
The liquid chlorine is pumped to the Production B area. The supply pressure is regulated by manually adjusting a recirculation valve at the pump. The liquefaction lead operator should be notified if a low or high supply pressure is experienced. A supply pressure of 120 to 130 psig is desirable at the EDC plant.
The other production units in Area B take liquid chlorine from the same supply system and should be notified of any intended large change in liquid chlorine consumption.
The liquid chlorine comes from the scale tanks to the chlorine vaporizers located on the southeast corner of the EDC plant slab. The chlorine vaporizers are arranged so that they can be operated individually, in series, or in parallel depending on the rate of vaporizing required.
A liquid chlorine stream from the vaporizers flows to the TriEthpne plant where it is vaporized and fed to the Tri-Ethane and HC1 plants. The purpose of sending the chlorine to be used in these two plants through the EDC vaporizers is to lower its oxygen content, which makes for a better reaction between chlorine and EDC in the Tri-Ethane plant.
SL 008570
CONFIDENTIAL:
Subject to Protective Order of 14th Judicial District Court
No. 91-1145
4"3
One major precaution which should be taken when operating the chlorine vaporizer is to be sure that the liquid chlorine is not turned on when there is no steam on the vaporizer. This would allow the chlorine feed system to fill with liquid chlorine which when introduced into the reactor would create a violent reaction and possibly do damage to the reactor or connecting equipment. Always turn steam on to the vaporizer first and allow the tubes to heat up some before turning on the chlorine supply
If steam failure occurs and the cause is not apparent or readily corrected, the liquid chlorine should be turned off. Possibilities of loss of stefsm to the vaporizer are:
a. Failure of the main steam supply. This would then make it necessary to shut down the whole plant.
b. Failure, of the steam trap on the vaporizer. The bypass around the trap can be opened and the unit operated this way until the trap is repaired.
e. Failure of the automatic steam pressure control valve. If this should occur, it is possible to operate with manual control of the steam pressure by means of the. by-pass around the automatic valve. This will re quire considerable, amount of attention when operating in this manner.
The. chlorine vaporizer will operate at the pressure imposed upon it by the chlorine feed system. From the vaporizers the vaporized chlorine can follow one of two routes to the. chlorine surge drum. When only liquid chlorine feed is being used, the vaporized chlorine passed through a pressure control valve and directly into the surge drum. The surge drum pressure is maintained at 35 psig by the pressure control valve. .
If a combination of liquid chlorine, and cell gas is being fed to the EDC plant the two streams are mixed at the surge drum. It is necessary to measure the individual streams before they are mixed. A system consisting of a pressure control station, a small surge drum and flow controller recorder station is used for measurement of the vaporized chlorine stream. The chlorine leaves the vaporizer and is pressure reduced to 45 ppig before entering the small surge drum. From the small surge drum it passes through the flow recordercontroller station to the large feed surge drum which operates at 35 psig.
The. chlorine cell gas comes to Area B directly from the discharge
of compressors in the liquefaction area. The EDC and wet HC1 plants use cell gas.
'The cell gas line pressure will be approximately 42 psig at the EDC plant but will vary some depending on the Area B consumption. For this reason the HC1 plant should be. notified before making changes in the rate of cell gas consumption.
SL 008571
CONFIDENTIAL: Subject to Protective Order
at 14th Judicial District Court No. 91-U45
4-4
Large variations in the amount of cell gas used in Area B will affect the liquefaction area operation. If the cell gas is not consumed as gas it has to be liquefied. A large cut in cell gas consumption in Area B would increase the liquefaction load and perhaps require start-up of additional liquefaction equipment. Therefore, the liquefaction area should be notified as soon as a consumption rate change is anticipated. The change should be made slowly if possible.
After the cell gas leaves the main header it passes through one of two systems which contains a pressure control valve and flow recorder. The two systems have different capacities and the one to be used is determined by the rate of cell gas consumption.
The cell gas passes next to the feed surge drum where it is mixed with the vaporized chlorine. The cell gas pressure control valve controls the surge drum pressure at 35 psig.
The chlorine flows through individual lines from the feed surge drum to each reactor. Each flow, regulated by an automatic flow recorder controller goes through a seal loop and a sparger system before entering the reactor.
Strip charts showing the'temperature, pressure and flow of the cell gas, vaporized chlorine and feed streams will be torn daily and sent to the Record Department for calculation of chlorine consumptions.
3. Chlorine Vaporizers, 60A-37-729: The chlorine vaporizers were manufactured by the Richard M. Armstrong Company. They are size "H" vertical vaporizers with an approximate capacity of 11,500 pounds of chlorine per hour. The vaporizers are 20" in diameter by 7.5' and have bayonet type tube heaters. The No. 1 vaporizerrhas approximately 1/3 of its tubes plugged to reduce its capacity for use at low production rates. The vaporizers are steam heated with low pressure steam. They are equipped with a steam pressure control valve which reduces the steam supply to the desired vaporizer chart pressure.
The vaporizers are protected against high pressure by a pressure relief valve set for 225 psig.
4. Small Chlorine Surge Drum, 60A-60-422; The small surge drum used in the vaporized chlorine measurement system is a steel vertical cylindrical tank with dished heads. The vessel is protected against high pressure by a three inch rupture disc which.will rupture if the pressure reaches 125 psig. A pressure relief valve set to relieve at 115 psig is mounted above the rupture disc.
5. Large Chlorine Surge Drum, 60A-60-465: The large surge drum is a steel vertical cylindrical tank with dished heads. The vessel is protected against high pressure by a 3" rupture disc which will rupture at 125 psig. A pressure relief valve set for 115 psig is mounted above the rupture disc.
SL 008572
CONFIDENTIAL: Subject to Protective Order Of 14th Judicial District Court
No. 91-1145
4_5
6. EDC Reactors. 60A-59-7, 60A-60-344: There are two reactors in the No. 1 EDC plant. The combined capacity of the reactors is 429 TPD.
The No. 1 reactor is a nickel-clad vessel that measures 8'0" 1,,D. by 43'0" tangent to tangent and sits on a 6' support skirt. The reactor is essentially an empty vessel, but contains a sparger feed distribution system, a boiling bed and a 10" nickel demistor
f The sparger system is constructed of 4" nickel pipe. Each feed stream has four spargers which extend 3*11" into the reactor and has a 3/16" slot 2I9" long in its bottom. The ethylene spargers are located 1'6" below the chlorine, spargers. The feed gas streams are fed to their respective spargers by means of a manifold that circle^",:,the reactor.
Located above the chlorine sparger system is a boiling bed support basket containing two layers of 3" ceramic spiral rings. The boiling bed dis tributes and breaks up gas and vapor bubbles so that the reactor will boil evenly.
The vapor leaving the reactor has a tendency to entrain with its liquid (containing FeCl3 and heavies). In order to remove this unwanted liquid from the vapor, a 10" nickel demistor is located in the top of the reactor with imprigement baffles just below it.
The No. 2 reactor is a verticle nickel-clad vessel that is 5'6" I.D. by 37' from bend line to bend line. It sits on a 6' support skirt.
The feed distribution or sparger system is constructed from 4" schedule 40 Ni pipe. Each pipe extends 2'8" into the reactor. The bottom of each pipe contains a 1/4" slot that is 2' long. Each feed system con sists of four spargers fed by a manifold which circles the reactor. The chlorine spargers are located 1'6" above the ethylene spargers.
The reactor is equipped with a boiling bed located just above the feed spargers and a 4" Ni demistor section which is located 3* from the top of the vessel.
Each reactor is protected against high pressure by a rupture disc which will rupture at 50 psig pressure.
The reactors are equipped with liquid level controllers which maintain a ponstant operating level. The No. 1 reactor normally is operated with a liquid level of approximately 24' while the No. 2 reactor is operated at approximately 18'. If it were not for the liquid level control system, the reactors would soon boil dry. It was mentioned previously that the reaction of chlorine and ethylene is exothermic. The heat generated in the formation of one mole of EDC is sufficient to vaporize over 6 moles of liquid EDC from the reactor. Therefore, it is necessary that the liquid EDC reflux stream be returned to the reactor to maintain the liquid level.
SL 008573
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
4-6
There are three ways to determine the liquid level in the reactors. First there are the sight glasses mounted on the side of the reactors. These glasses are used for checking the liquid level control when the need arises. Normally these sight glasses will be closed off and drained. Light shining on the sight glass containing EDC will cause further reaction of the material to form undesirable heavies.
A. second way to determine the reactor level is to read the indi cated pressure near the bottom of the reactor. Each foot of reactor liquor will impose, about 0.5 psi on the pressure guage. Knowing this pressure and the pressure in the vapor space of the reactor the liquid level can be calculated using the following equation.
Reactor Level
-
(Et. Above. Press. Tap)
Bottom Press., psig - Vap. Space Press., $sig 0.497 psi/ft.
The other system for determining the reactor level is the level control instrument. This instrument provides a record of the reactor levels at the panel board. Incorporated into the controller is a high and low level alarm to notify the operator of trouble in the reactors.
The normal operating temperature of the reactors will be between 208F at the bottom and 194F at the top. Should the temperature increase to 225F due to an uncontrolled reaction, high ack pressure, insufficient re flux, etc., the reactor should be shut down until the difficulty can be resolved.
The reactors will be operated with an excess of ethylene at all times. This is about the most important thing to remember about the control of the reactor. If it is desired to increase the production rate of the plants, the ethylene flow is increased first. Then the' chlorine flow is in creased to the desired rate-. The reverse procedure is followed in cutting the production rate. The chlorine flow is now decreased first; then the ethylene flow. These procedures will provide the desired slight excess of ethylene that will he vented through the stack seal at all times.
A violent explosion can occur if chlorine and ethylene, are mixed in the reactor vapor space. This is the reason for operating the reactor with an excess of ethylene. When an excess of ethylene is being used no free chlorine will get into the vapor space. Should the ethylene flow drop below the chlorine flow, however, chlorine gas will accumulate in the vapor space. If the lower explosive limit of chlorine and ethylene is reached an explosion may occur. Never change from excess ethylene to excess chlorine.
If a deficiency of ethylene is noted and an explosion has not occurred, start a nitrogen purge through the system and add sufficient ethylene, for the excess.
There will always be some HC1 in the vapors coming off of the EDC reactors. The HC1 is due mainly to the substitution reaction of EDC and chlorine to give TCg and HC1.
SL 008574
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
A certain amount of heavy chlorinated compounds called tars will be formed in the reactor. These do not vaporize overhead and will accumulate in the reactor liquor. Periodically, some of the reactor liquor will be drained from the. bottom of the reactor into the clean-up kettle. Here the EDC will be vaporized and returned to the No. 2 reactor vapor space. The tars will be drained from the kettle into drums and discarded.
7. Reactor Condensers, 60A-71-466 and 730: There are two horizontally mounted reactor condensers. The reactor vapor enters the shell side of the condensers midway at the top. Cooling tower water is on the tube side of each exchanger. The shells and tubes are constructed of nickel.
These exchangers are designed to cool the reactor vapors from 190F to 167F and condense a corresponding amount of EDC.
8. Reactor Gas Separator, 60A-60-345: The. reactor gas separator is a horizontal cylindrical tank with ellipical heads. The tank dimension^ are 5'-6" X.D. by 15'-0" tangent to tangent. The material of construction is nickel clad steel.
The tank is equipped with a sight glass and a field mounted liquid level, controller. If the tank level goes high or low an alarm sounds at the panel board.
The separator is protected against high pressure by a rupture disc which will rupture at 50 psig.
9. HC1 Stripper, 60A-60-333; The stripper is fed reactor crude from the reactor gas separator by one of two reactor pumps. The flow forward to the stripper is controlled by the reactor gas separator level controller. The flow is measured and recorded at the jianel board.
The stripper is a Ni-clad vertical vessel 4'-9" in diameter by 28' and sits on a 16' support skirt. The column is packed with 18' of 1 1/2 inch Intalox saddles. The packing support is located 5'6" from the bottom of the column and has two rows of 3" x 3" partition rings on it to support the 1 1/2" saddles. A distributor plate is located above the packing to give complete distribution of the liquid feed and reflux.
A thermosiphon reboiler circulates liquor from the bottom of the stripper. Some of the liquid is vaporized in the reboiler tubes and passes up through the column to be condensed and refluxed to the stripper. The stripper boil-up rate is regulated by controlling the flow of steam to the reboiler with the steam flow recorder controller located at the panel board. The stripper reboiler level is indicated by a sight gauge located on the side of the stripper.
The purpose of the stripper is to strip the discharged HC1 and other light components from the crude EDC. These light materials go off the top of the column with the vaporized EDC and gas through the stripper condenser where most of the EDC is condensed. The HC1 and light components and some EDC that does not condense go to the separator condenser where they are combined with the reactor vent stream.
SL 008575
IcUlSubjec
of 14th
4F
CON t to Ju <3
No.
IDENTITY: Pro t-pc-ti-va
or
BUtrict
91-11*5
dor Cour
t
4-8
The stripper is protected against surges in pressure by a rupture disc which will rupture at 50 psig.
10. Stripper Condenser, 60A-71-469 and 723; There are two horizontally mounted stripper condensers. The stripper overhead vapors pass through the single pass shell, side of the condenser. Cooling tower water is on the four passes tube side. Each exchanger contains 106-1" tubes 14' long. The tubes and shell are. of nickel construction.
Valves in the cooling water return lines are adjusted to give the proper cooling water discharge temperature.
11. Stripper Gas Separator, 60A-60-334: The EDC condensed in the stripper condensers passes to the stripper gas separator. The nickel vessel is a horizontal cylindrical tank with ellipitical heads and measures 4' I.D. by 10' tangent to tangent.
The stripper gas separator has a field mounted level controller which maintains a constant level by controlling the stripper reflux flow rate. If the separator level drops low or rises too high an alarm sounds at the panel board. A sight gauge is mounted on the gas separator and is used for checking and setting the level controller.
The separator is protected against high pressure by a 6" rupture disc which will rupture if the pressure reaches 50 psig.
12. Stripper Reflux Drier, 60A-73-18: The stripper reflux stream is pumped through a CaCl2 packed drier to insure against water contamination in the stripper system. If water gets into the stripper system it will come overhead with the stripper vapor stream and be removed in the reflux drier.
The. reflux drier is a vertical cylindrical vessel with a dished bottom. The top is fitted with a blind flange cover.
A support grid is fastened at the bottom of the drier. A layer of glass wool will be placed over the grid before the drier is charged with calcium chloride desiccant. To prevent the carry over of large desiccant particles, a grid is located in the top section of the drier and is fastened to the blind flange cover.
When the drier has been in use for some time a heavy liquid phase of CaCl2 in water will form in the bottom. While there is still solid desiccant in the drier the reflux will continue to be dried. However, as the solid desiccant is used up the treated EDC water content will rise. When the pre determined maximum water concentration is reached the drier will have to be recharged. Liquid CaCl2 brine can be drained off the bottom of the drier. The remaining mass of wetted CaCl2 can then be washed out of the drier with water. Water remaining in the drier after wash-out should be swept out with nitrogen.
The reflux drier will be by-passed while being recharged.
SL 008576
CONFIDENTIAL: Subject to Protective Order Of 14th Judicial District Court
No. 91-1145
4-9
13. Process Crude Tank, 60A-60-335: The carbon steel crude tank receives the stripper bottoms stream through a stand'leg. The tank is a horizontal vessel with dished heads and is 8.5' by 17' tangent to tangent.
The crude tank is equipped with a level recorder at the panel board and a sight glass which is used to check and set the recorder. It is protected against high pressure by a 6" rupture disc which will rupture if the pressure reaches 50 psig.
14. Distillation Column, 60A-70-38: The EDC still is designed to remove the high boiling impurities from the liquid EDC and to limit the loss of EDC in the heavies purge stream. The column will produce an EDC overhead product of 99.9% purity. EDC loss to the bottoms stream will be limited to less than 1.0%.
The column is made of carbon steel and is 5' 8 1/4" I.D. by 88' 4" tangent to tangent. A cylindrical skirt 12' 5" tall supports the still. Four manways are provided for access to the inside of the column.
The still is fitted with two thermosiphon reboilers. It is expected that the heavies which will collect and be purged from the bottom of the column will have a tendency to "crack" to form carbonaceous substances or coke. This material will build up deposits on the tubes of the reboiler in service and reduce the heat transfer capability of the reboiler. Valves are provided so either of the two reboilers can be valved off from the column for removal and cleaning.
Phosplex-L is added to the still reboiler to prevent cracking and thus reduce tube fouling. Free iron in the reboiler increases cracking. The Phosplex-L ties up the iron and renders it inactive as a cracking catalyst. It is added continuously from an elevated drum through a rotometer.
The composition of the liquor in the still reboiler will vary proportionately with its temperature and will remain constant if the tempera ture is held constant. The steam flow rate to the still reboiler is controlled by a temperature controller which controls the temperature in the reboiler of the column. The temperature control valve may have to be adjusted from time to time by the operators to compensate for changes in the bottom or over head composition. Need for these changes will be dictated by analyses of the product and bottoms stream.
The reboilers are single pass on both sides and constructed of carbon steel.
The column contains 54 trays fitted with 161 valve caps per tray. The trays are numbered from bottom to top. All trays are on an 18" spacing except the 27th and 28th trays. They are on a 24" spacing for the manways. The valve units on the trays are the V-l Ballast unit as manufactured by Fritz W. Glitsch and Sons, Dallas, Texas. The trays are made of 12-gauge carbon steel, and the V-l valves are made of type 410 stainless steel.
SL 008577
:1:
Subject to Prole l j. v'G of 14th Judicial t fr.lri
Order : t court
No. 91*"-1- 145
4-10
The trays all have straight segment downcomers made of 1/4" plate that is weeded in place. The downcomer section of each tray has an area of 1.231 ft . Each downcomer is 16 1/2" tall, and thus, the overflow area onto each tray is 1 1/2". The downcomer from the No. 1 tray is the only exception. This downcomer is 62" long to provide a seal into the bottoms liquid of the column. All downcomers are extended 3" above their respective trays to provide a 3" overflow weir. The weirs are notched 1/2" on all trays above the 27th tray (lowest feed tray) but below this tray they are straight. The overflow weir is 40" long.
The trays are clamped into place on the tray support rings. Each tray is fitted with a 24" manway which is removable from either top or bottom. The trays are packed with Garlock 900 and AAA grade asbestos tape and wicking.
39th tray.
Feed to the column can be introduced on the 27th, 31st, 35th or
The column is fitted with 14 sample valves and 14 thermocouple wells. The sample points are paired with the thermocouple wells on the 2nd, 4th and 8th trays and thereafter on every 4th tray. The points sample the liquid for a particular tray as it is flowing through the downcomer to the tray below.
Feed to the column is set at a rate which is determined by the plant production rate. The feed rate may be changed by the plant operators to take care of level variations in the process crude tank.
The liquid feed starts down through the column from the feed point. In the course of its flow across each tray it comes in contact with the vapors generated by the reboiler. These vapors strip the EDC from the liquid and rectify the EDC toward the top of the column. The net results is a build-up of pure EDC in the top of the column and a concentration, of feed impurities such as TCE in the bottom.
The vapors leaving the top of the column are condensed in the still condenser and the condensate collected in the still reflux drum. A pre determined portion of the liquids in the still reflux drum is returned to the top tray of the column via the reflux flow control valve. The amount of liquid reflux to be returned to the column is set by the operator. Under normal loading conditions the reflux will be approximately one-half of the liquid flow from the still reflux drum.
The liquid in the still reflux drum that is not returned to the column is drawn out of the column as product. The plant product is pumped to the product transfer tanks for storage or to the Tri-Ethane plant as feed. The amount of EDC going to the Tri-Ethane plant is controlled by the TriEthane operator. The product flow to storage is automatically controlled by the product level control valve, which gets its control signal from the reflux
drum.
SL 008578
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
4-11
A nitrogen gas line is tied in to the still condenser to provide a constant pressure of 1 1/2" water on the column. This is necessary to pre vent pressure, and consequently temperature, fluctuations in the column. The padding system should always be in service when the still is being operated. The gas supply comes from the pressure regulator located at the transfer tanks.
From the above description it should be evident that the operators of the still must thoroughly know and understand the column before they can successfully control its operation.
15. Still Condenser, 60A-71-471.733; Vapor from the still passes to the horizontally-mounted steel heat exchangers where complete condensation takes place. The EDC vapors pass through the one pass shell side of the ex changer with cooling tower water on the four pass tube side. Valves in the return cooling water lines are adjusted to give the desired cooling water dis charge temperature.
The condensers are padded with nitrogen and a vent line is pro vided for bleeding inerts from the still system to the vent stack.
16. Still Reflux Drum, 60A-60-337: The still reflux drum receives condensed EDC from the still condenser through a stand leg.
This vessel is a horizontal cylindrical tank with dished heads and measures 4.0* by 10.O' tangent to tangent. It is constructed of carbon steel. The. reflux drum is equipped with a sight gauge and a field mounted level controller. The level controller controls the product flow rate to storage such that the reflux drum level is constant. High and low level alarms are provided on the panel board to indicate any imbalance, in the EDC product system.
The vessel is protected against high pressure by a 4" rupture disc which will rupture if the pressure reaches 50 psig.
B. Equipment on Plant Exit Streams
1. EDC Product to Storage:
a. Product Coolers, 60A-71-473,735
The carbon steel product coolers are mounted horizontally and have a one pass shell side and one pass tube side. EDC is on the shell side and cooling tower water is on the tube side. The cooling water flow rate is manually controlled with valves in the return lines to maintain the desired discharge temperature.
b. Product Neutralizers
The product neutralizers are steel chambers 18" x 9' high located at the northeast end of the process pad. The chambers are packed with anhydrous flake caustic. The purpose of the neutralizers is to hold the HC1 and iron concentration within the specification limits. When the still
SL 008579
CC'Ni." Subject to dr
of 14 th Judi>-
Ive Order L) j ~ trict Court
No 91-1145
4-12
reflux HC1 concentration exceeds a predetermined value the product will be passed through the neutralizer. The efficiency of the neutralizer can be checked by analyzing the still reflux stream and the product stream. The only difference between these two samples is that the product stream has passed through the product neutralizer.
It will be necessary to recharge the neutralizer periodically. One neutralizer will be used while the other is being recharged.
c. Product Storage Tanks:
and transfer.
Refer to Section VIII for a discussion of product storage
2. Vent Gas Disposal: The final vent stream from the EDO plant is composed primarily of inerts which enter the plant as impurities with the feeds, unreacted ethylene and chlorine, HC1, and methane. The several processing steps applied to this vent gas are covered below.
a. Separator Condensers, 60A-71-731,467
Vapors from the reactor condensers, reactor gas separator, stripper condensers and stripper gas separator are vented through the separator condensers. The condenser condensate flows back to the reactor gas separator through a stand leg.
The No. 1 condenser is a horizontally mounted nickel condenser with one pass on both the shell and tube sides. The vent gas is on the shell side of the exchanger with cooling tower water on the tube side. The exchanger has 68 one inch nickel tubes, 61 long. The shell is constructed of nickel and has a 13 1/4" O.D.
The No. 2 separator condenser is a horizontally mounted nickel exchanger with one pass on both the shell and tube sides. Vent gas is on the shell side of the exchanger with cooling tower water on the tube side. The exchanger has 125 one inch nickel tubes, 6' long. The nickel shell is 18" O.D,
b. Methane Addition System
The oxygen content of the chlorine feed passes through the reactor unreacted and can form an explosive gas mixture with the combustibles in the vent stream. To prevent an explosive vent gas mixture methane is added downstream of the separator condenser to adjust the concentration of com bustible materials to a value above its upper explosive limit.
The concentration of oxygen in the vent stream is measured and recorded by the chromatograph. An oxygen content of less than 10% in the vent stream has been found to be safe under normal operating conditions and will not allow an explosive gas mixture to be formed during a plant upset. Therefore the amount of methane added to the vent stream is regulated to main tain an oxygen content of less than 10%. The methane flow is controlled by a control valve which is manually adjusted at the control panel.
SL 008580
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
, 4-13
The flow of methane is measured and recorded on a strip chart at the control panel. This strip chart should be torn daily and sent to the Record Department along with the methane temperature and pressure readings for methane, consumption calculations.
c. Vent Condenser, 60A-71-468,
The vent gases from the separator condensers pass to the vent condenser where refrigeration is used to recover potential EDC losses. The condensate from the condenser flows back to the reactor gas separator.
The vent gases are cooled in the two pass tube side by Freon-12 on the one pass shell side. The exchanger has 86 one inch nickel tubes, 12' long.
The vent stream leaves the condenser through a vapor separator which knocks out and collects any EDC liquid that might be entrained in the vent stream. The vapor separator is a nickel vessel 14" O.D, x 20" high. It con tains a 5" layer of wire mesh in the top.
d. Seal Pot and Stack
The vent stream is then scrubbed with water at the stack seal pot. The seal pot is a 2' diameter by 8' high Haveg tank where the vent stream passes countercurrent to a spray of water. The water washes the HC1 out of the vent stream to prevent venting it to the atmosphere. The HC1 con taining water is sewered. The. scrubbing water is the blow-down stream from the cooling tower and will be runjat a set tate regardless of the plant pro duction rate. The remaining vent stream passes up the exhaust stack to the atmosphere. The 4n diameter Chemtite exhaust stack is attached to the side of the distillation .column for support.
The piping to and from the seal pot is constructed of Chemtite pipe. This was used for corrosion protection since the. water at the stack seal contains HC1. The last few feet of the exhaust stack is made of Hastalloy. Since the material of which the final vent stream is composed is highly flam mable, it is possible that the vent could catch fire from static electricity or lightning. The last section of Hastalloy pipe is to prevent the Chemtite pipe from being damaged from the heat produced if this should happen.
At the junction of the Chemtite and Hastalloy pipe a flame arrestor is installed. This serves as a block to prevent a flame from travel ing. down the exhaust stack if a fire were to start.
A steam line, runs to the top of the exhaust stack and discharges at the stack opening. If the vent stream ever catches fire, it can be be ex tinguished by discharging steam into the exhaust stack. A manual steam valve is located on the north end of the catwalk above the pipe galley and can be opened if a fire should ever occur.
SL 008581
Subject i:j Lmc-.'.'-Live Order of 14th Judicfai District Court
-to. 91-114 5
4-14
e. Refrigeration
The system employed to cool the vent stream is a direct ex pansion refrigeration system using Freon-12. The compressor is a Carrier Cor poration Model 5H40 operating at 1160 rpm. The compressor is protected by the following safety devices:
1) The oil failure switch shuts off the compressor motor if the compressor oil pressure drops below 18 psi greater than the compressor suction pressure. It can be manually reset when the oil pressure goes aboVe 11 psi greater than the compressor suction pressure. The pressure switch is connected to a thermal switch which it energizes if the oil pressure drops be low the specified amount. The* thermal switch takes approximately one minute to cut off the compressor. After this switch has been activated, three minutes must be allowed for it to cool before it can be manually reset and the com pressor started.
2) The high pressure cut-off. This switch cuts off the com pressor if the head pressure goes above 151 psig and resets at 113 psig.
3) Low pressure cut-off. This switch cuts off the compressor if the suction pressure drops below 20" vacuum and resets at 10" vacuum.
The compressor is equipped with an unloading device activated by the suction pressure which allows the compressor cylinders to be cut out one at a time and thereby reduce the refrigeration capacity of the machine stepwise. This is necessary to be able to operate the refrigeration system satisfactorily at reduced ethylene dichloride production rates. The manual unloading valve is located on the bell cover in front of the compressor. When this valve is turned counter clockwise as far as it will go the compressor is full loaded. By turn ing it clockwise the compressor will unload three cylinders, one at a time, re ducing the refrigeration capacity by one-fourth as each cylinder is unloaded.
The compressor is also equipped with an oil filter and a crackcase heater. The crankcase heater is used when the compressor is not running to prevent the accumulation of refrigerant in the crankcase oil when the com pressor is put in operation. The oil filter has a throwaway element which should be changed periodically.
Manual discharge and suction shut-off valves are located on the compressor. The compressor should never be started up or operated with the discharge valve closed. This can result in serious damage to the compressor.
A suction strainer is provided in the low pressure Freon stream. This strainer is located at the rear of the compressor.
The compressor heads are cooled by a circulating stream of cooling water. Manually adjust the flow of water until its exit temperature is approximately 100F.
SL 008582
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
Do. 91-1145
4-15
The low pressure Freon passes from the vent condenser through a double pipe heat exchanger to the Freon compressor. The low pressure Freon cools the liquid Freon to remove the super-heat. This also insures complete vaporization of any entrained liquid Freon that may be in the low pressure gas stream. Liquid Freon returning to the compressor can cause considerable damage to the machine.
The high pressure Freon condenses in the water cooled con denser and is then drained to the vent condenser through the double pipe exchanger and a liquid seal valve. The purpose of this valve is to keep a liquid seal on the Freon condenser to prevent gaseous Freon from entering the vent condenser without condensing. The Freon is condensed on the shell side of the Freon condenser with cooling water on the tube side. The Freon is then vaporized on the shell side of the vent condenser by the vent con denser load.
The vaporized Freon passes from the vent condenser and returns to the suction of the compressor via the double pipe exchanger as the low pressure stream.
3. Flasher, 60A-70-47: Feed for the flasher comes from the bottoms storage tanks. This flow is controlled by a flow control valve and the rate may be read from a field-mounted indicator. Steam to the flasher reboiler is controlled by the level in the flasher.
The bottoms vaporized by the reboiler are condensed by the flasher condenser and collected in the flasher condensate tank. When the condensate tank becomes full the liquid is pumped to the reactor dump tank for storage until it can be sent to the Per-Tri plant.
The heavy impurities in the flasher feed stream concentrate in the flasher bottom and are drained periodically for disposal.
4. Clean-Up Kettle, 60A-60-331: The clean-up kettle is a jacketed 500 gal. steel kettle. EDC that is to be cleaned up is pumped from the reactors or the dump tanks to the kettle and evaporated by means of steam in the kettle jacket. The vapors from the kettle go off the top and are piped to the No. 2 reactor vapor space. Here they combine with the reactor vapors and are con densed in the reactor condenser. The heavies retained in the kettle are drained to drums and discarded. Steam to the kettle is automatically pressure controlled. The rest of the system is manually controlled.
Provisions are also made for using the clean-up kettle for catalyst mixing. This will be discussed in Section IX,
C. Utilities
The utilities for the EDC plant include cooling tower water, instrument air, steam, and the electrical system.
SL 008583
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court 1. Cooling Tower Water: liCoo. olQin1g-T1 o14we5 r water for the No. EDC plant and the MC plant is supplied by four connected units.
4-16 1 and No.
2
The No. 1 cooling tower was manufactured by the Water Cooling Equipment Company. The tower is constructed of creosate-treated redwood. This unit is a two-cell, forced draft tower in which the air is drawn from the bottom through a section packed with redwood slats. The draft is created by fans located at the top of each tower cell. The tower is designed to handle a recirculation rate of 1700 gpm at 90 to 115F temperature rise.
The No. 2 cooling tower was manufactured by the Foster Wheeler Corporation. The tower is constructed of redwood and is a two-cell, forced shaft tower. The. tower is designed to handle a recirculation rate of 5,000 gpm at 90 to 115'F temperature rise.
The No. 3 and No. 4 cooling towers were manufactured by the DeFlon Anderson Company. The towers are one-cell, forced draft towers constructed of redwood. These towers are sheathed with Lascolite fiberglass panels. Each tower is designed to handle a recirculation rate of 2,500 gpm at 90 to 115 F temperature rise.
The water enters a distribution tray on top of the towers and showers down through the packed section countercurrent to the flow of air. In this fashion, the air is saturated with water vapor. The evaporation necessary to provide the water vapor cools the water until the exit tempera ture approaches the air wet bulb temperature. This temperature of the exit water will be below the ambient air temperature, but is dependent upon the humidity. Design temperature is 90F.
The cooled water is pumped from the tower basin through the process coolers by the cooling tower pumps and back to the distribution tray on top of the tower.
A purge stream is required on the cooling tower water to prevent the accumulation of minerals in the water. Tn the case of this location, the chloride content of the make-up water is the controlling factor. This should be controlled at approximately 4-5 times the make-up chloride content by the purge rate. This purge stream is discharged through the vent stack seal of the No. 1 EDC plant and must remain on as long as the cooling tower is in operation.
To make up for the purge stream and the evaporation (windage) losses, well water is continuously added to the tower basin. The flow of well water is level controlled to maintain the proper level in the tower basins
To insure the proper life of the tower and to prevent corrosion and scaling of the exchanger walls, the tower water is continuously treated. The types of treatment and how they are controlled are as follows:
SL 008584
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
a. pH Control
4-17
A continuous recording pH meter allows the operator to regulate the addition of sulfuric acid to the tower to keep the water slightly acid. An acid pH is required for two reasons; one Is to guard the redwood from damage which occurs in an alkaline system; two is to keep the mineral solubility high enough to prevent scaling on the exchanger walls.
b. Chromate - Phosphate Addition
A control analysis for chromate-phosphate concentration will be run periodically and the addition regulated to give the desired concentra tion. These materials are used as corrosion inhibitors. They provide the metallic surfaces exposed to the cooling water with a protective film to keep down excessive corrosion.
c. Betz 107 Addition
Betz 107 is a specially blended organic anti-foulant and corrosion inhibitor which is used in combination with the chromate-phosphate blend (Betz P-40).
d. Chlorine Addition
Chlorine is added to the cooling tower water to prevent the formation of algea and slimes in the tower. This is particularly important in the summer since there these can form in sufficient quantities to plug up the tower distribution trays and even the piping if an algaecide is not present.
The cooling tower water is shock chlorinated three times per week. The residual chlorine level is raised to 0.75 ppm during these treat ments. The chlorine is added directly from a ton chlorine cylinder.
A water treatment firm (Betz) will tell us what treatment is necessary and what concentration should be maintained. They will check the tower operation periodically (once per month) and make necessary recommenda tions.
Betz 107 and P-40 and sulfuric acid are added continuously to the cooling tower water by gravity flow into water aspirators that discharge into the cooling tower basin. The rate of addition is controlled by adjusting the discharge valve on the individual storage tanks.
2. Instrument Air System:
a. Compressors
The compressors for the system were manufactured by the Joy Manufacturing Company. They are Model WG09S compressors. They are water cooled, single stage, double acting, heavy duty, vertical compressors--designed to operate at a maximum pressure of 100 psig. Number 1, 2 and 3 compressors
SL 008585
CONFIDENTIAL:
Subject
to
Protective
Order ct Court
of 14th
4-18
have 10" x 9" cylinders. Number 4 and 5 compressors have 8" x 7" cylinders.
Number 1, 2 and 3 compressors are driven by Westinghouse, 60 HP, 1800 RPM, 440 volt, 3 phase induction motors. Number 4 and 5 com pressors are driven by General Electric, 40 HP, 1770 RPM, 440 volt, 3 phase induction motors.
Since these compressors are essentially positive displacement machines there must be provisions to allow for variation in their output. These machines are operated as constant speed compressors and they have been provided with an electro-pneumatic constant speed unloading system for load variation. This system consists of an automatic pressure switch, a manual transfer switch, and a three way valve. The pressure switch senses the dis charge pressure, and if the pressure goes above the desired maximum level (as would occur when the compressor output is more than the air being con sumed) , the pressure switch changes the three way valve and allows the com pressor cylinders to unload (the compressor valves are blocked open so no compression can occur). The compressor will continue to operate in this manner until the discharge pressure lowers (90 psig) and then the pressure switch will automatically load the cylinders and compress up to 100 psig.
The compressor can be manually unloaded by putting the transfer switch, located on the side of the compressor, in the "OFF" position. The compressor will run with no load until the transfer switch is placed in the "ON" position. This switch is used when starting up the compressor to allow it to be started under no load. Note: The compressor should always be started up and shut down with the transfer switch in the "OFF" position.
A condensate trap is also located on the side of the compressor for collection of water. This should be drained periodically.
b. Aftercoolers
The discharge of the compressors is piped to four pipeline shell-and-tube type aftercoolers. These units are piped for countercurrent flow with compressed air on the tube side and cooling water on the shell side.
The aftercoolers discharge into moisture separators. These separators reduce the air velocity and reverse the air flow, thus separating free moisture and oil. These liquids are trapped and isolated in a bottom reservior. They are automatically removed from this reservior via a condensate trap installation.
c. Driers
The air from the separators flows to two sets of air driers which were manufactured by the C. M. Kemp Manufacturing Company. The number one drier consists of two towers connected in parallel. Each tower contains 335 pounds of silica gel and has a capacity of 500 SCFM of air. The unit is
SL 008586
! oni Gubj^^'-; tc Protective Order
;..Gi District Court
of 14 th ouav No 21-1145
4-19
fully automatic and electrically reactivated. The reversal cycle is 4 hours; the heating period for reactivation is 3 1/2 hours. The number two unit con sists of two towers connected in parallel. Each tower contains 170 pounds of silica gel and has a capacity of 300 SCFM of air. This unit is steam re activated and fully automatic. The reversal cycle is 6 hours; the heating period for reactivation is 4 hours.
d. Distribution
The air from the air driers is piped to a receiver tank which is located just outside the south side of the compressor building. This receiver is designed to smooth out surges and pulsations in the air supply and to provide a reservoir of air for periods of peak demand.
From the instrument air receiver, the air flows directly into the instrument air distribution header.
3. Steam Supply: The 12" steam line which comes across the road and into Area "B" brings 400 psig steam to the plant. An 8" line leaves the 12" main header and enters the EDC plant. The steam passes through a pressure reducing station and is metered. Here the pressure is reduced to 175 psig by a self-contained control valve before going to the individual vessels where it is controlled to meet the specific pressure or flow needs.
4. Electrical System:
a. General
Power for the organics area is presently being supplied by two 13.8 KV feeders. Feeder H-138 fed from power house bus No. 4 feeds directly into the EDC-Tri Ethane 13.8 KV bus. Feeder H-104 fed from power house but No. 1 feeds the EC-HC1-VC 13.8 KV bus. Feeder H-104 can feed the EDC-Tri Ethane Area through tie switches and breakers. The feeder is switched by oil circuit breaker No. 138 which is controlled only at the Powerhouse switchboard. After following an underground and overhead route, the 13.8 KV feeder is terminated at the interrupter switch located within the south cubicle of 13.8 KV metalclad switchgear in the Control Building. The door on this cubicle cannot be opened unless breaker No. 138 is open and in the lowered position thereby releasing the key which opens the interrupter switch cubicle door. Closing this interrupter switch connects the 13.8 KV feeder to the bus contained within the metalclad switchgear. The north cubicle of 13.8 KV switchgear contains a fused interrupter switch, the load side of which is connected to the primary of the 750 KVA transformer. Voltage is stepped down from 13.8 KV to 480 volts in the 750 KVA transformer. The transformer secondary is connected to the terminals of an air circuit breaker in the 480 volt switchgear which in turn supplies the 480 volt bus located within this switchgear. Three (3) circuit breakers connected to this bus supply power to two motor control centers which contain motor starters and circuit breakers for control of individual loads.
SL 008587
CeWvrA DiiWTiAL: Subject to Protective Order
14th Jure caal District Court No. 91-1145 4-20
b. 13.8 KV Metalclad Switchgear
Unit No. 1 contains a manually Operated 3-phase load in terrupter switch rated 1200 amperes continuous and interrupting. Also in cluded are fuses which are sized to protect the 750 KVA transformer. The door to this cubicle, cannot be opened unless the switch is in the open posi tion. In passing, it should be pointed out that any three phase fused switch or circuit presents the possibility of single-phasing due to only one fuse blowing thus leaving two lines connected to the load. The motors are protected by the motor starters for this condition. If a single fuse blows and the re maining two fuses happen to be on the lines which supply lighting, then light ing would be normal but motors would be dropping off the line. The simplest check for this situation is to determine it current is.flowing in all three phases of the transformer secondary by reading the ammeter located on the 480 volt switchgear. Current in. only two phases would indicate a single blown fuse, and the transformer should be taken off the line.
c. 750 KVA transformer
The transformer supplying power for the operating equipment is rated 750 KVA, 1.3,800/480 volts, ana is a sealed dry-type transformer. The unit is filled with dry nitrogen which serves as an insulating and cooling medium. Lightfting arrestors provide surge voltage protection. The transformer is equipped with alarm and indicating devices for pressure and temperature. Pressure should not exceed 10 1/2 psi under any condition since permanent tank distortion may result from higher pressures. A red alarm on the instrument control panel indicates excessive pressure which can be corrected only by re ducing load on the transformer. An amber alarm indicates excessive vacuum, but it is very unlikely that this situation will occur. Normal pressure for the transformer when de-energized is between 1 and 1.5 psi, the pressure in creasing with load to approximately 7 psi at rated load. Although it is not desirable to do so, the transformer can be operated with no pressure.
A hottest spot indicator-relay is provided having alarm con tacts which operate at 210^0 and 225C. An amber alarm will indicate that the transformer has reached 210C. This is the rated temperature. The trans former should not be loaded beyond this point. A second alarm at 225 C provides additional protection. Lower the temperature by decreasing the load.
d. 480 Volt Switchgear
The 480 volt switchgear is metal enclosed and equipped with draw-out type manual air circuit breakers. The unit is equipped with a 1200 amp. main breaker which ls connected to the transformer secondary terminals. When closed this circuit breaker energizes the bus within the unit. Power is distributed by three 600 amp. draw-out type manual air circuit breakers to three motor control centers which are located in the Control Building and one in the Air Compressor Building. Metering for 480 volt power is provided in this unit consisting of an ammeter with selector switch, a voltmeter with selector switch, and a watthour meter. A ground detector device is included to indicate grounds cn the 480 volt system. A single phase to ground condition will sound an alarm at the control board. This situation should be remedied as soon as reasonably possible.
SL 008588
$ u b "j o c t I of 14th j
"ot'.ecUve Order 'rict Court 4-21
e. Motor Control Centers
Three motor control centers are installed, one in the Air Compressor Building and two in the Control Building. Process pump motors on dual or spared pump installations are arranged so that the two motors involved are fed from different motor control centers. All important motors are pro vided with shutdown alarms which annunciate at the control board. Each motor starter is equipped with a control transformer which reduces the voltage at the pushbutton stations to 110 volts. Three over-load relays are provided to improve motor overload protection.
f. Instrument Power and Lighting
Instrument power and emergency lighting are supplied by a 10 KVA, 480/120 volt, single phase transformer which receives power from an automatic transfer panel. In case of power failure on the bus normally feed ing the 10 KVA transformer, relays will automatically switch to a feeder which originates at an emergency power sub-station at the Per-Tri plant.
Normal lighting is supplied by the EDC No. 1 lighting trans former. A lighting panel is provided on the north wall of the Control Building starter room.
Yard lighting is accomplished by the use of mercury vapor floodlights. These lights are controlled by circuit breaker Circuit No. 6623) which must be operated manually.
Lighting panels have been provided on the north wall of the starter room. The east panel contains circuits for general lighting while the west panel contains emergency and critical lighting. The emergency panel is fed from a distrilmtion panel on the south wall of the starter roon, which is connected to the 10 KVA transformer previously mentioned.
g. Installation Methods and Equipment Classification
The. characteristics of EDC are such that it is classified in Group D, Class I by the National Electrical Code. Ethylene, however, is clas sified in Group C, Class I. The method and materials of installation are those recommended by Factory Insurance Association. In general, the installa tion is Class I, Group D, Division 2. Motors are TEFC, lighting is vaportight, and all arcing devices are explosion proof with seal-offs. Since the Control Building is pressurized and removed from the process area, general purpose equipment is used with the exception of the laboratory which requires a Class I, Group D, Division 1 installation. Seal-offs are provided in all conduits leaving the Control Building on the process side as required for conf duits entering a hazardous area from a non-hazardous area. Seals are also provided for conduits leaving the Control Building but not entering a hazardous area. However, this is to prevent flow of air due to pressurization of the Control Building.
SL 008589
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145 h. Relamping
4-22
Although vapor-tight fixtures are used in the process area, it is felt that some precaution should be used when relamping. The procedure will be to first determine lamps which need changing by turning on all lights. Then ttirn off all lights and relamp. To simplify this procedure, circuit breakers for lights in the process area and control laboratory have been grouped in the lighting panels. Globes and guards must be replaced after relamping.
i. Grounding
Grounding in the EDC plant has been given special attention due to problems peculiar to the handling of hydrocarbons and the location of the process area. Grounds for motors and other electrical devices are con tained in the conduit supplying the device and connected to the device frame internally. Motor change-outs should be followed up to see that the ground has been connected.
Due to the tendency for hydrocarbons to build up a static electricity charge as a result of movement or agitation, a system of jumpers for pipe flanges has been installed to provide metallic continuity of the piping system. All vessels are grounded at two points. The result is a system of lines, tanks, and vessels operating at ground potential. This will not prevent the generation of static charges but should provide adequate leakage to ground to prevent the accumulation of dangerous charges.
The nearness of the radio transmitting station north of the process area presents a problem in that metal objects will act as receivers of radio frequency energy. It is not practically possible to prevent this effect. It is known that the energy picked up will be amplified if the height of the object is a multiple of the transmitter wave length. The height of the still approaches this condition. The grounding system on the still should eliminate personal hazard and to some degree, act as a shield to equipment south of the still.
A particular hazard is created by the use of cranes with long booms. Under certain conditions, depending on boom length and crane location, it is possible to pick up a voltage high enough to burn the person handling a load that is suspended from the crane. This will occur even if the crane is grounded. It is also conceivable that an arc would occur if the crane hooks touch a grounded object.
It is obviously important that the grounding system be main tained intact. This should be kept in mind when performing maintenance work on any equipment in the EDC area.
SL 008590
o 141:1
LL.. rotoelive Order aJ District Court
i'iQ . 91-1145
4-23
D. Instrumentation
1. General: One of the major requirements in a plant like the EDC plant is smooth, uninterrupted control of the plant streams in order to obtain specification grade product. For instance, a distillation column can not be operated with varying flows. A column like the EDC still can take hours to level out after an upset and rapid changes in operating conditions can cause poor quality product during the upset period. To obtain the desired type of control, the EDC plant has been equipped with automatic instruments whenever possible.
Even though a thorough job of instrumentation has been done on the EDC plant, certain items must be understood to get full and efficient use of the instruments. The instruments are the operators tools and how he uses them determines how efficiently the plant will operate and the quality of the product.
All important control points in the EDC plant are transmitted to the control room where they are indicated or recorded. The first sign of trouble within the plant will generally be from the instruments. These should be continually checked for indications of abnormalities. Most of the recorders or indicators will be read and the data recorded on the log sheets.
The instruments serve also as a safety guard. All points in the plant which can cause serious trouble or operating difficulties have been equipped with alarm devices to give warning when abnormalities occur. If an alarm sounds for any reason, it should be checked immediately. DO NOT IGNORE THE WARNING SYSTEM. It is there for your protection as well as for the pro tection of the equipment.
2. Alarm System: When an abnormality occurs, it will be alarmed by a horn blowing and by a flashing light on t,he panel board. Under normal opera tions, the warning lights will show green. If a high flow, pressure, level, etc. occurs, the horn will blow and the warning light will flash red. If a low flow, pressure or level occurs, the horn will blow and the warning light will flash amber. Pumps are also connected to warning lights. As long as a pump is in operation, the light on the panel board will remain green. If for any reapon the pump stops the horn will blow and an amber light will flash.
The horn will continue to blow and the light flash until an acknowledgement is made. This is done by pressing the acknowledgement button located on the panel board. When this button is pressed, the horn will stop and the light will stop flashing. But, until the trouble is corrected, the light will show either red or amber depending on the nature of the trouble. When the correction is made the light will change back to green. A list of the alarm points and their settings are given in Table 4.2, page 4-31,
$L 008591
CONFIDENTIAL:
Subject tn Protect:' ve Order
of 14 th Jut
- ` r.i ct Court
Jo. 3 1 - x 14 j
4. 24
3. Checking Alarm: A failure in the alarm system could result is serious trouble. For this reason, the alarm system should be checked periodical' ly to be sure it is functioning properly. To check it, pull out on the acknowl edge button and turn it to the high alarm. Check all warning lights to see that they show red. If they do not, there is either a burned-out bulb or a defect in the circuit--either of which should be corrected immediately. Then turn the button to low alarm and check the warning lights again. Make this check once per shift. Safe operation depends upon a properly functioning alarm system.
4. Instrument Operation: The recorder-controller instruments are provided with manual and automatic operation. Under normal conditions, these will be operated on automatic control, but during start-up or shut-down, or possibly in the case of trouble, the manual control can be used. When on manual control, the valve can be operated from the panel board by regulating the output to the control valve. The output will remain at the valve set by the manual set point adjusting knob while the instrument is on manual control and the valve opening will not vary.
When the instrument is on automatic control, the set point is ad justed to the desired control point by the set point adjusting knob. The in strument will then attempt to regulate the process to this control point by opening and closing the automatic valve.
The automatic control valves go from full open to full closed (or vice versa in the case of an air pressure opening- valve) at an output pressure variation of 3 to 15 psig.
On the pneumatic controller the output pressure is indicated on the scale at the top. The. approximate opening of the valve is indicated on this scale, i.e., 9 psig output is half open, 6 psig and 12 psig are 1/4 and 3/4 open or vice versa depending on the valve action. At proper control, the set point and the indicator pen will remain opposite each other. The opening and closing of the automatic valve to maintain this condition will be shown by the variation in output air pressure.
5. Bumpless Transfer: The controllers can be readily switched from manual to automatic, or automatic to manual control, but care must be exercised when doing this. If the controllers are not switched correctly, a snap action of the automatic valve will occur. This will upset the system as well as be hard on the instruments.
The following procedure should be followed when making the trans fer on pneumatic controllers:
a. Manual to Automatic
(1) Set the transfer lever to the "Seal" position. This isolates the control valve from the controller air circuits and seals the pressure that is on the control valve at that time.
(2) Adjust the set point adjusting knob until the set pointer indicates the same output pressure as the output gauge.
SL 008592
Subje ct
CObFIbEVmAb. r' v- * -1 n J
Orrier it Court
4-25
(3) Set the transfer lever to the "Automatic" position- The process is now on automatic control.
b. Automatic to Manual
(1) Note the output pressure and then set the transfer lever to the "Seal" position.
(2) Adjust the set pointer with the set point adjusting knob until it corresponds to the same pressure as noted in step one.
(3) Set the transfer lever to the manual position. The process is now on manual control.
6. Set Point Changes: The number one rule for operation of this type of plant is smooth steady control. The purpose of automatic instruments is to provide this control and they should be handled with this in mind.
The instrument set point will be set at the desired control point. The instrument will then regulate the control valve until this point corresponds to what is actually occurring in the process. By raising or lowering the set point, the control point is changed accordingly. It must be remembered, though, that when a set point change is made the instrument will attempt to correct for this change, immediately. If a large, change is made, this could result in complete opening or closing of the automatic valve and cause a severe enough change in the process variable to upset the system. In some cases the rapid change may not have any adverse affects, but in others this could be a definite upset. How rapid a change can be made depends strictly upon the operation that is being performed. For example, the feed to the stripper can withstand con siderable variation without particularly bothering the rest of the system. But, the feed to the distillation column should be changed step-wise and the set point gradually worked up to the desired valve so that the rest of the column controls have sufficient time to regulate to the change. This is also true for changes in ethylene and chlorine feed to the reactor.
7. Pressure Gauges with Protector Bowls; Some pressure gauges in the EDC plant have been equipped with protector bowls. These bowls are liquidfilled and the liquid is separated from the process stream with a flexible diaphragm. The purpose of these bowls is to protect the gauge from corrosion by the process streams and still give an accurate pressure indication. If one of these gauges fails to function for any reason, do not replace just the gauge. The gauge and protector bowl must be removed as a unit and a new unit installed since they are factory sealed full of silicone oil.
8. Instrument Trouble Shooting: Instrumentation can and does con tribute its share of problems, especially during plant start-ups. Unless in struments are given special care when being checked out and put into service, process operations may be seriously handicapped.
SL 008593
CONFIDENTIAL: Subject to protective Order of 14th Judicial Disau t Court
No. 91-1145
4-26
During initial operations, plant personnel should become familiar with the characteristics of the instruments in the plant. Operators should learn to recognize the normal state of their instruments and check them by supplementary observation of physical conditions in the process. Comparing centralized recorder-controller instrument readings with spot observations will show whether all is well.
The operator should neither trust or distrust his instruments. When something appears to be out of line, do not draw conclusions without having supporting data. Watch trends in process variables and thus be better prepared to recognize a true deviation in the process.
Instruments should be calibrated against standards if there are questions. This is particularly important when instrumentation is vulnerable to straying or where process upsets have disrupted instrument accuracy.
In starting up a plant, it is normal practice to use manual con trols until the flows and operating conditions are properly leveled out. There is often a tendency to attempt automatic control before it has been established that suitable operation of the process is possible. On the other hand, de laying the switch to automatic control can also cause problems. Close coopera tion between the operating personnel should be maintained in switching from manual to automatic.
Some typical checks for instrument troubleshooting during start up are summarized in Table 4.3. Operating personnel can significantly reduce downtime caused by instrument problems, if they follow such a check list.
E. Pressurizing and air conditioning system for EDC Control Building
1. General: The EDC Control Building, with the exception of the Control Laboratory, is completely air conditioned and pressurized by equip ment located on the second floor in the northwest corner. Air conditioning was required since the building had to be pressurized so that other than explosion-proof equipment could be installed in the building. The Control Laboratory is not air conditioned since there cannot be any open connection between the laboratory and the rest of the building. The equipment is de signed to maintain a constant temperature and to prevent the relative humidity from going above 70% while keeping the pressure in the building at approximately 1/4" water. Refer to Figure 4.2 , page 4-34 . Diagrams of both the pneumatic and electrical controls are shown.
IN CASE OF FAILURE OF THE PRESSURIZING AND/OR AIR CONDITIONING SYSTEM NOTIFY THE SUPERVISOR AT ONCE. DO NOT OPEN DOORS AND WINDOWS FOR VENTILATION AS THE POSSIBLE DRAWING IN OF GASES COULD RESULT IN AN EXPLOSION OR FIRE.
2. Pressurizing System: The pressurizing system consists of an air intake on the roof which connects through a suction duct to an Ilg BC-135 Blower. The blower discharges air through a motorized damper into a plenum which contains filters and directs the air toward the suction of the packaged air conditioning unit. This blower is rated at 2520 cfm or 1580 cfm at 1/4" water depending on the speed at which it is set.
SL 008594
CONFIDENTIAL:
Subject to Protective Order of 14th Judicial District Court
Mo. 91-1145
w/
The blower motor is 3/4 hp, 440 volts with the start-stop con trols located at the motor control center. An emergency stop button is located in the Control Room on the first floor and a warning light is located on the alarm panel of the main panel board to give indication of failure of operation of the motor.
The pressurizing controls are Minneapolis-Honeywell and any maintenance on them is to be done by the Minneapolis-Honeywell Service Mechanic ONLY. In case the controls malfunction, call the supervisor. Operators should not attempt to correct the difficulty.
The pressurizing controls operate the damper on the blower dis charge to allow only sufficient air to enter the building to balance the losses and maintain a 1/4" water pressure within the building.
Personnel working in the building will notice an outrush of air each time a door is opened and if this is not noticed the pressurizing system should be checked. All windows should be kept shut and doors should be open only for passage.
A solenoid valve on the damper control is wired into the blower motor control circuit so that the damper will remain closed when the blower is off. This will prevent the pulling in of outside air at ground level through the stack effect of the outside air intake on the roof.
Operation of Pressurizing System:
To Start a. Start fan at motor control center. b. Check blower outlet in front of unit to be sure unit is operating.
To Stop
Stop fan at motor control center or at emergency stop on first floor.
Controls
Static pressure regulator should be set at 1/4" water by MinneapolisHoneywell Service Mechanic.
Maintenance
a. Fan and Blower: Service Department. As required for PM. b. Pneumatic Controls: Minneapolis-Honeywell. Four month check. c. Filters: Air Conduit. Monthly clean or replace.
Comments
a. Keep all windows shut and open doors only for passage. b. Failure of blower motor is indicated on alarm panel on panel
board.
SL 008595
t? I.J j ^ 1 - *
'
of 14th judjLci'.i
trict Court
Mo. 91-1145
4-28
3. Air Conditioning System: The central air conditioning system is composed of an 8-ton Chrysler Airtemp unit which has its suction at the unit on the second floor and discharges through a series of ductwork to the various rooms on the first floor. Air return from the first floor is through grills in the false ceiling and the second floor. The unit uses well water in its condenser.
The package unit is equipped with electric heating colls in addition to the cooling equipment.
The Chrysler Airtemp package unit is covered in the service con tract with Air Conduit Company and their mechanics only should work on the unit. They will check the unit and clean or change filters once a month. In case of malfunction of the unit, contact the supervisor.
The air conditioning control system is composed of two parts; one which controls temperature and one which controls the relative humidity. Temperature control is maintained by the action of the thermostat located on the center wall on the ground floor. This thermostat resets the control point of the submaster Grad-U-Stat located in the supply air duct which energizes the cooling circuit through a pneumatic-electric relay or energizes four stages of electric heat in sequence through pneumatic-electric relays to reset the supply air temperature. The humidity is controlled by the humidistat, located adjacent to the thermostat, which energizes the cooling circuit through a pneumatic-electrie relay. The cooling of the air removes moisture on the coils and if cold air is not required the submaster Grad-UStat will energize the heating system to warm the air.
Operation of |Air conditioning system
To Start
a. Turn well water valve on to unit. b. Energize circuit 6724 at motor control center. c. Energize Circuits 6724-1, 6724-2 and control transformer
at auxiliary control panel adjacent unit. Unit will not operate with control transformer off. d. Start unit by turning rotary switch on front of unit to "Cooling" position. e. Turn thermostat rotary switch on front of unit clockwise to highest position. It should be left in this position at all times.
To Stop
a. Stop unit by turning rotary switch on front of unit to "OFF" position.
b. De-energize circuits at auxiliary control panel or motor control center as required.
SL 008596
Controls
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No.
4.29
a. Set thermostat on first floor at 78F. (Plus or minus 2 depending on exterior weather conditions.)
b. Set humidistat on first floor at 70% R.H. Do not set at lower values.
Maintenance
a. Electrical and Plumbing: Service Department. As required. b. Package Unit: Air Conduit Company. Monthly check, c. Pneumatic Controls: Minneapolis-Honeywell. Four month
check.
Comment
This unit does not have a low pressure water cutoff and should be shut down whenever the well water is shut off. If not, unit will overload and shut down anyway but damage could be done.
SL 008597
Subject - / \ ; ' `,;^cl court ? 14 th 3 uu l - - ^ " A
No.
TABLE 4.1 SAFETY RELIEF DEVICES
4-30
Equipment CI2 Vaporizers Small CI2 Surge Drum Large CI2 Surge Drum No. 1 Dump Tank No. 2 Dump Tank No. 1 Reactor No. 2 Reactor Clean-Up Kettle Reactor Gas Separator Stripper Stripper Gas Separator Crude Tank Still Still Reflux Drum Flasher Flasher Accumulator
Type Relief
Relief Valves
Rupture Disc Relief Valve Rupture Disc Relief Valve Rupture Disc
Rupture Disc
Rupture Disc
Rupture Disc
Rupture Disc
Rupture Disc
Rupture Disc
Rupture Disc
Rupture Disc Rupture Disc
Rupture Disc Rupture Disc Rupture Disc
Size Inches
3 3 3 3 8 6 10 6 3 6 4 4 6 6 4 2 2
Relief Setting . ps 225
125 115 125 115
50
50
50
50
50
50
50
50
50
50
50
50
50
SL 008598
CONFIDENTIAL:
Subject to Protective Order of 14th .Judicial DistrJlcc Court
Ho. 91-1145
4-31
TABLE 4. 2 ALARM SETTINGS
Service
V ariable
Chlorine Chlorine Ethylene Ethylene
Liquid Pressure Feed Pressure 165# Pressure Feed Pressure
Reactor #1 Reactor #2 Reactor Reactor Gas Separator Stripper Gas Separator Crude Tank Still Reflux Drum Storage Tanks Cooling Tower Steam to Stripper
Level Level Pressure Level Level Level Level Level pH Flow
Setting High
Low
150 psig
110 psig
40 psig
30 psig
175 psig
155 psig
50 psig
40 psig
26 ft. 20 ft. 8 psig 4. 5 ft. 3 ft. 7 ft. 3 ft. 25' -6"
-- ______
22 ft. 16 ft.
--
2 ft. 1 ft. 2 ft. 1 ft. 4'-6" 6 1, 225#/H
SL 008599
Of
VvJA', Su/bjejecctt Lc
Juci-
J- U Sj
Pro: Irj ]_
'1 -AL:
-o civa D i o r -1
Order
Ho. 91-if-4 g ct Court
TABLE 4.3
TIPS ON INSTRUMENT TROUBLESHOOTING
4-32
I. Recorders and Recorder-Controllers
Trouble (A): Pen Dead at Zero
Cause: (1) Check isolating valves at process impulse line; see that equalizing valve is shut. (2) Look for plugged impulse line. (3) In case of pneumatic transmitter, check air supply to transmitter. (4) Look for broken or loose lines. (5) Primary sensory device not installed. (6) Be sure process step is actually in operation.
Trouble (B): Recorders with two or more pens record at the same point on the chart, but should be at different points.
Cause: (1) Pens may not pass owing to mechanical interference. (2) Make sure instrument leads are clear and properly connected.
Trouble (C): Chart not moving
Cause: (1) Chart loose on hub. (2) Chart loose on chart rewind roll, (3) Clock not running; power not on drive.
Trouble (D): Chart readings apparently not correct or not consistent with local gauges.
Cause: (1) Trouble in gauge movement. (2) Gauge may not have been read properly. (3) Check agreement of chart with transmitter range. (4) Check agreement of output pressure from transmitter with pen.
II. Control Valves
Trouble. (A) ; Valves do not respond to output change.
Cause: (1) If valve has a valve positioner, check its air supply. (2) Check for leaking air lines. (3) Valve stem may be stuck.
Trouble (B); Valve changes position, but brings about no change in process flow.
Cause: (1) Valve may be plugged. (2) Block valves in process line may be closed.
SL- 008600
PUflJMATlC-F.LEr.TBlf. RELLAY WHEL
CONFIDENTIM *
Subject to Protect -of 14th Judicial Dif
Ho. 91-U^
y-;1 a f
REVISIONS
.NSgy/, f.t/XMV6t0TAO-<C4I4R.247ZS 2* . -`fLkp PAg 4-3 f/ae/ae 4.S
AUXILIARY ELECTRICAL rOATTROLPAllLL
.f.tei*
VE.WQQRS--LJ1R1NG Dt^R/kM STQM AISTEMP UNIT
sfc`5 4
41
U H9
(D O
*No u
O U O
d) H
>P
1 1
5 C
'H 4J
4inJ
^in
o
+< a> p i
* o rH rH
* i p ra <t>
if & -H
u.
* 0 1H3 Zo
)3
*i 3
V
CJ J3
TT 4J
A 3
Cft
QKJRfcEF.LIME DIAGRAM
E.LE-MEMTARY DIAGRAM CIR.<iW-;42 STOW WR.TE.MP UWIT
CO
o
GO
O)
o
RE.F. P^G-
i
4600Aa- 3lOaa ctOoCkitPrLoAlVm.fr.dM&A.SaTiErR. cOoWuo6.L,h1SeaTting,4pres%.equi?
ALUSEJEwAT.OPRVAEtRVTICSOOEufCtTVOHOWELTRTORORAUlWAWSMFIRA: IFNl MGCTOPNWETR*RlEOLL7ESMTOEfNFTTUAHRRENYISfHtTDECIDAWGMRAAlfVfMtERNHDpOR
COLUMBIA-SOUTHERN CHEMICAL CORP.
suBSaHAir of ftttsmjbgh puie ouss ca
TAKE CHARLES.LOUISIANA
606. r. Tm i E.CC PLAKfT_
COMTROL BLDG. AIR COUOITIOUIUG UMIT
RHEUMATIC 4 ELECTRICAL COUTRQL OIA&BABS
m
n..3-n-6o
,$p >-- r*ATg S~lQ'itQ 6oZ.6iZ
KoiuimDWG. no&OA-32^- 1
CONFIDENTIAL*;
Subject to of 14th juaioi-IDL.J
NO. 'Jl"1145
n ,er Court
5-2
d. Pressurize the chlorine feed line as per chlorine system start-up procedure.
e. Bring the ethylene flow up to the desired flow rate (refer to Figure 14.1, page 14-2) while simultaneously following stepwise with the chlorine flow increases.
f. Bring the chlorine flow up to the desired flow rate; refer to Figure 14.1, page 14-2.
g. The reactor level will rise until the reactor temperature reaches approximately 185 to 190 F and the vapors start to distill over at the top.
h. The reactor gas separator level will now begin to rise as EDC is made in the reactor.
i. At the sign of the level increase in the reactor gas separa tor, start the reactor pump and put the reactor level control in service.
j. The stripper should be up to temperature and about lined out on total reflux by this time with the top temperature close to 185 to 190F. Start the feed from the reactor gas separator to the stripper.
k. As soon as the proper operating level is obtained in the stripper gas separator, stop recirculating EDC from the crude tank back to the stripper.
1. Set the stripper reboiler steam flow to give the desired reflux ratio. (One pound of 175# steam will vaporize approximately 6.3 pounds of EDC.)
m. When the desired level is obtained in the crude tank, start the still feed at a flow rate about equivalent to the stripper feed rate or production rate. The still feed rate is adjusted by the operator to hold a constant level in the crude tank.
n. The level will begin to rise in the still reflux drum. When the drum level reaches the half-way mark open the product line to the product cooler and on to storage.
o. The EDC still bottoms can be pumped to storage periodically.
B. Detailed Equipment Start-up
1. Reboiler Start-up and Operation: Three thermosiphon reboilers are used in the EDC plant; one is on the HC1 stripper, two are on the distilla tion column. The principle of the thermosiphon reboiler is to obtain a rapid circulation through the exchanger tubes by vaporizing the liquid in the tubes and allowing the vapors to leave the top of the exchanger and enter the side
SL 008602
CONFIDENTIAL: Subject to Pro'.:' live Order o 14th Juoinrl bLstrict Court
No. lfi-114 5
5-3
of the column below the first tray or support plate. The vaporized material is replaced by liquid which comes down from the first tray in the still through a liquid leg into the bottom of the exchanger. This vaporization creates a natural circulation of liquid (thermosiphon) through the reboiler, thus elimi nating any need for pumps. The rapid circulation rate through the exchanger accomplishes two purposes; first, a high rate of heat transfer to the liquid is effected due to the high thermosiphon liquid velocity obtained; secondly, this high liquid velocity makes the formation of scale or tars on the exchanger walls more difficult and thereby either eliminates the need for cleaning the exchanger walls or greatly extends the period of operation between cleanings over what would be experienced in a static kettle-type reboiler.
Three very important items must be remembered when starting up and operating a thermosiphon reboiler. First, never let a reboiler run dry or operate with a low level. This allows some or all of the tubes to become dry and heat up to the temperature of the steam. This excessively high tempera ture can cause baking of the tars on to the tube, decomposition of the material in the reboiler, or even formation of more tars which can plug the reboiler tubes. The liquid level in the column should always be operated above the top tube sheet of the reboiler to provide for proper circulation rates.
Secondly, when starting up a cold reboiler, drain all accumulated steam condensate out of the shell of the exchanger and start the steam feed slowly. Gradually increase the steam until the reboiler comes up to tempera ture. Leave the steam condensate valve at the bottom of the reboiler open a slight amount and purge wet steam until the tubes have a chance to warm up. This procedure prevents bumping which occurs when live steam contacts cold condensate and it also prevents slugging of the liquid phase in the reboiler tubes. Either of these conditions can damage a reboiler if they became violent enough.
Thirdly, never run a reboiler with a high level, especially when the liquid in the reboiler blocks or partially blocks the vapor outlet of the reboiler. This will stop the thermosiphon and drastically reduce the heat transfer. If this happens, the still must be shut down, the reboiler level
lowered to the proper level and the still started up again to re-establish circulation.
If a reboiler is failing to supply the design heat flux, and foul ing is not involved, check the steam supply and/or the condensate trap. The trap may be inoperable and cause water to back up into the reboiler. When steam is at the proper pressure and the condensate trap is working, but there is still no heat transfer, chances are the tubes are fouled. In the case of the EDC still, there are two reboilers. One is a spare. The dirty exchanger should be cleaned up so as to be ready for service as soon as possible.
2. Start-up and Operation of Process Pumps: All process pumps in the EDC plant are centrifugal pumps with external mechanical seals. The mechanical seals by their nature, present some items which should be noted when starting up or operating these pumps.
SL 008603
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
The seal rings for these seals are made of ceramic. For this reason, the seal should be protected from mechanical or thermal shock or the ceramic ring could crack. Be careful of an extreme temperature shock such as might occur if water was sprayed on a hot seal while washing down the area. Mechanical shock to either a running or an out of service seal could be damaging.
The seals are equipped with a back flush line which comes from the discharge of the pump. The purpose of this line is to provide a liquid flush past the face of the seal to keep foreign matter from collecting under it and damaging the surface. If the flow through this line is at a high enough pressure, though, it can actually cause the seal to leak. For this reason the pumps should always be operated with the valve in the seal flush line only about 1/2 open. If a seal starts to leak, close down on this valve a little more. If the leak is caused by excessive seal fluid pressure, re stricting the valve should stop the leak. If this does not affect the leak, then it is caused by a defective seal.
The correct procedure for starting up a centrifugal pump is to open the suction line and start the pump with the discharge valve closed. When the pump is running, slowly open the discharge valve to keep from slugging liquid through the piping. When starting a pump against a shut-off valve the discharge pressure would be great enough to cause the mechanical seal to leak if the back-flush line were open too wide. For this reason, always have the flush valve almost closed when starting the pump. After the pump is running with an open discharge, open the flush valve about half way.
A centrifugal pump can run with a closed discharge valve for a short period of time with no harm. But, if it is allowed to operate this way for an extended length of time, the pump will eventually heat up suffi ciently to vaporize the ethylene dichloride. This creates gas bubbles at the pump suction and essentially allows the pump to run dry or cavitate which can damage the seal. A centrifugal pump should never be operated dry (no liquid in the lines). Since there is no fluid to lubricate the seal, it can be seriously damaged.
3. Utilities:
a. Electrical System
To provide 3 phase, 440 volt and 1 phase 115/230 volt power for the No. 1 EDO plant, the switching sequence is as follows: (Assuming that all breakers and switches are open and clear of hold tags, and all equipment is in operating condition.)
(1) Call the powerhouse switchboard operator and request him to close the 13.8 KV OCB No. H-138.
008604 SL
order
subject " ^'af Diitti ct Court
of
14th
Ju^C"i-1145
NO.
5-5
(2) Close the manually operated 13.8 KV disconnect No. 0-138 after the powerhouse acknowledges that OCB H-138 is closed.
(3) Close manually operated 13.8 KV fused disconnect No. 0-301. The 750 KVA 13.8 KV/440 volt transformer is now energized.
(4) Check for 3 phase, 440 volt power at the 440 volt metalclad switchgear. All three phases should read the same voltage; if not, it is possible that a 13.8 KV fuse in the switch cubicle No. 0-301 is blown or there may be trouble in the volt meter circuit. Call the service depart ment for an electrician to clear the problem before proceeding further. Should the voltage check properly, you may proceed.
(5) Check the transformer pressure. The gauge should indi cate between 1 and 7 psig. The reading will vary with load but should never exceed 10 1/2 psig.
(6) Check the transformer for proper temperature. The temperature should not exceed 210C.
(7) Close the 440 v. A.C.B. Note: Be alert at this time for a ground alarm indication. If ground conditions are indicated, log the last switch which operated before the. alarm sounded, silence the alarm and proceed with switching. When switching is complete, notify the service de partment as soon as possible of the ground condition.
(8) Close the metalclad 440 v. A.C.B.'s Numbers 6500, 6600 and 6700. Voltage, is now available at the motor control center buses. In dividual units of equipment may now be started as desired by closing the starter breaker and the start pushbutton; usually located near the drive motor.
(9) After all switching is complete and the station is on the line, check the volt and ampere meters to determine if the system is normal.
b. Instrument Air System
The following procedure should be followed when starting up the instrument air system.
(1) Line up system piping. Be sure the 1/2" air pressure impulse line is open to the compressor. Drain the receiver tank. Be sure to close the drain valve after having drained the receiver tank.
(2) Start the air driers. The driers will be automatically switched and reactivated.
(3) Open cooling water to the aftercoolers.
SL 008605
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No* Si-li4->
5-6
(4) Close the liquid discharge from the separators. At least for initial start-up, leave the separator discharges closed until a water level appears in the sight glass. When a liquid level appears in the sight glass open the separator discharges. Be sure the by-passes to the liquid traps are closed. The traps must operate with water in it. After each shut-down, the traps should normally retain water thus eliminating Step 4.
(5) Open cooling water to the compressor jacket.
(6) Unload the compressor by turning the transfer switch to the "OFF*' position. Make sure there is an oil level in the bullseye.
(25-40 psig).
(7) Start the compressor motor. Check the oil pressure
(8) Load the compressor by turning the transfer switch to the "ON" position. Watch to see that the compressor unloads at 100 psig and loads at 90 psig (approximately).
activated.
(9) Start dry air purge (14 SCFM) to the drier being re
Periodic checks that should be made on the compressor opera tion are listed below;
(1) Check oil level and pressure.
(2) Check the compressor belt tension by observation only.
(3) Check the flow of cooling water to the compressors and aftercoolers by feel for proper temperature (slightly warm).
normally.
(4) Check the separator liquid level. No level should appear
(5) Check the drier operation. The drier being reactivated should be hot and have no pressure on it. The drier on stream will be cool and have pressure on it (100 psig).
(6) Check air temperature (80-100F) and pressure (100 psig).
(7) Drain the moisture trap on the electro-pneumatic control system by opening the pet-cock momentarily.
c. Steam Supply
The following procedure should be followed when starting up the steam supply:
(1) If 400 psig steam is not on to the EDC plant open the main supply valve located at the south end of the plant. Open the by-pass around the steam trap at the. 175 psig reducing station and allow steam to bleed through the line until it has warmed up.
SL 008606
i ' - i'r4* j i \ f/ j'!' w r . i' v' ( ,* ,, i \ j_i I
S'.iijiccr r,--> :
v. ivg Or dor
of I4th Judic i oDistrict Court
iio. 91-1145
5-7
(2) Check to see that all steam users in the plant are off.
(3) Crack the valve on the steam line to the vent stack to allow a bleed through the steam header.
(4) Open manual block valves on either side of the 175 psig reducing station.
(5) Slowly pressurize the steam header by raising the set point on the steam controller. Allow time for the line to warm up.
(6) Set the steam controller to give 175 psig steam. Use the gauge on the down-stream side of the control valve to adjust the pressure.
put in use.
(7) Continue to bleed steam through the header until it is
(8) Set individual pressure reducer stations and flow control stations as required.
steam.
(9) Check all steam traps periodically to insure against wet
d. Cooling Tower System
cooling tower:
The following procedure should be used when starting up the
(1) Turn on well water make-up and fill the tower basin to the required level.
(2) Provide a full supply of treatment chemicals.
(3) Turn on the pH meter and check its operation.
(4) Start the tower fans.
(5) Open up cooling water lines through the reactor condenser, separator condenser, stripper condenser, still condenser, and product cooler.
(6) Start up the cooling tower pumps. Start the pumps with the discharge valve closed and open the discharge slowly,
(7) Start treatment chemical addition to the tower.
of the tower.
(8) Check for proper return flow and distribution at the top
(9) Check fans and pumps for proper operation after they have been running for a few minutes.
SL 008607
CONFIDENTIAL: Subject to Pi:otootive Order Of 14th Judicial D: . ! Court
No.
5-8
Periodic checks that should be made on the cooling tower operation are listed below:
(1) Check the pH.
(2) Check the automatic pH meter by sampling the cooling water and testing with the laboratory pH meter.
(3) Check treatment chemical addition.
(4) Run test for treatment chemical concentrations and adjust chemical addition flows accordingly.
bearings.
(5) Check operation of fans and pumps for vibration or hot
4. Refrigeration System: The following procedure should be followed in starting up the refrigeration system for the vent condenser:
a. Check oil level in crank case (1/2 sight glass).
b. Turn on cooling water to Freon condenser.
c,, Turn on cooling water to compressor head.
d. Open Freon discharge valves through system. Open com pressor suction valve only a slight amount.
e. Start the compressor and open the suction valve slowly; listen to make sure no liquid is being fed to the suction. Liquid in the compressor suction will cause knocking.
f. Open oil drain line about one turn.
Feriodic checks that should be made on the refrigeration system operation are listed below:
a. Be sure liquid Freon is not being fed to the suction of the compressor.
b. Check the suction and discharge pressures.
c. Check the oil level.
d. Check the compressor cooling water discharge. Should be approximately 100F.
e. Check the oil pressure (40 psi above suction pressure).
f. Check the water temperature on the Freon condenser.
SL 008608
CONFIDENTIAL: S i' b r-r. _ ' o > '.I. '.-Cf. .ive Order o i.U'L C'c" Icini District Court
Co. 91-1145
5-9
Detailed instruction for maintaining this system are included in the Carrier operating manual.
5. Stack Seal: To put the stack seal on line, turn on the water flow to the top of the vent scrubber. Cooling tower blowdown and cooling water from the Freon condenser are used on the stack seal. Its flow is controlled manually and indicated on a rotometer.
6. Ethylene Supply System:
Start-up Procedure
a. Check the controller by-pass valves to be sure they are closed.
b. Open ethylene supply to the feed pressure control station.
c. Set pressure control valve set point at 45 psig.
d. Open by-pass around the pressure control valve and pressurize the ethylene line up to the flow control valve to 45 psig.
e. Ethylene is ready to be fed to the reactor. The remaining steps in the ethylene system start-up procedure are described under reactor start-up.
Check Points
a. Be sure by-pass valves are closed around the pressure and flow control valves.
b. Be sure all instrument impulse lines are open in the system,
7. Chlorine Supply System:
a. Liquid Chlorine
(1) Check all chlorine lines and be sure that all by-pass and block valves are closed.
(2) Line up the liquid chlorine from tank 7 or 8 in lique faction to the last manual valve before the chlorine vaporizers in the EDC plant. If MC or HC1 is already in operation, do not close valve on the liquid chlorine line to MC.
(3) Check the chlorine pressure and flow control valves for proper operation. Someone should observe the movements of these valves in the field. After checking, close the valves at the panel board.
5I_ 008609
or(Jer Subjec t to prCMD-e^i^s-trict court of l*th
5-10
(4) Start steam to the vaporizer slowly. Warm up the vaporizer by by-passing the steam trap until live steam starts passing through the trap by-pass. Check the steam pressure reducing station operation.
(5) Slowly open the liquid chlorine line to the vaporizer,
(6) After chlorine has had time to warm up, slowly pressurize the large chlorine surge drum to 35 psig using the pressure control valve by pass. If cell gas is going to be used the small chlorine surge drum system will be pressurized to 45 psig.
(7) The remainder of the start-up described is discussed under reactor start-up.
(8) The other vaporizer can be brought up by slowly opening the vapor line, slowly turning on the. steam to warm, the vaporizer and then opening the liquid chlorine block valve.
(9) When the vaporizers are on line the MC chlorine feed can be switched to pass through the vaporizer and thus have its oxygen content reduced. Close the block valve in the liquid line supplying MC directly.
Check Points
(1) Be sure all by-pass valves are closed.
(2) Steam to vaporizer.
Note: Never open liquid chlorine to a cold vaporizer nor close the liquid and vapor lines off with steam on the vaporizer. Do not trap liquid chlorine between closed block valves.
b. Cell Gas
(1) Check out the cell gas line to see that chlorine is available to the EDC plant. Notify the liquefaction operator of intended use of cell gas.
to be used.
(2) Open instrument impulse lines on orifice run that is
(3) Set the cell gas pressure control valve at 35 psig and slowly open the upstream and downstream block valves around the pressure con trol valve.
Note: Some liquid chlorine will always be used in the No. 1 EDC plant. Therefore the plant will be operating when the cell gas feed system is put in service.
st. 0086J0
Subjiu:-'- in
L-n^civo Order
of 14th Judicial District Court
No. 51-1115
5-11
8. Reactor: The following procedure should be used when starting up the reactor: (Refer to Figure 14.1, page 14.2 for ethylene and chlorine flow rates.)
a. The reactor level should be 24 or 18 feet respectively for the No. 1 and No. 2 reactors before start-up. Adjust the level with material from the reactor gas separator if necessary.
b. Check reactor for a vacuum and break it with nitrogen if one exists.
c. Be sure all instrument impulse lines are open,
d. Check to be sure cooling water is on the reactor and separator condensers. Have the refrigeration unit ready for start-up.
e. Line up the reactor vent piping through the stack seal and vent stack. Be sure sufficient scrubbing water is going to the stack seal and methane is available at the methane flow control valve.
f. Be sure the dump tank and rework kettles are isolated from the reactor system.
g. Open manual valves between the, reactor level control valve and the reactor pump. Open the manual valve between the reactor pump and the reactor gas separator leaving only the pump discharge closed.
headers.
h. Open the manual valves in the chlorine and ethylene sparger
i. The reactor is now ready for start-up. Open the block valves around the ethylene flow control valve and check to see if the valve leaks through. 'pen the block valves around the chlorine flow control valve and check it for leak through.
j. Start the ethylene flow first by opening up the ethylene flow control valve with remote manual control. Do not open valve too fast. Bring the ethylene flow rate stepwise up to the desired set point and switch to automatic control. Follow the increase in ethylene flow with stepwise increases in chlorine flow.
k. Start the chlorine flow by opening the chlorine flow control valve with remote manual control. Do not start chlorine flow until the ethylene flow has been started. Bring the flow rate up to the desired set point and switch to automatic control.
l. The reactor is now in operation except for the reflux flow. When the reactor temperature comes up and the level starts dropping, start refrigeration unit and adjust the reactor level controller set-point to the proper setting.
SL 008611
COr'FIDEiiTIAL: Subject to Protective Order Of 14th Judicial District Court
No. 91-1145
5-12
m. Shut off the nitrogen purge if it is in service.
n. Start the reactor reflux pump and begin recycle to the reactor.
o. The reactor is now on automatic control. As soon as the proper operating level is obtained in the reactor gas separator start feed from the separator to the stripper.
9. HC1 Stripper: Refer to Figure 14.2, page 14-3 for the curves that will be used to determine the stripper reboiler steam flow (which determines the stripper reflux ratio).
Start-up Procedure
a. Check for cooling water flow to the stripper condenser and for proper steam pressure up to the reboiler steam flow control valve.
b. Check to be sure the reboiler is full of liquid. The re boiler should be filled to the stripper overflow take-off line. If the level is low pump EDC to the stripper from the reactor gas separator or stripper gas separator to obtain the proper level.
c. Open manual valves between the stripper gas separator and stripper reflux pump.
d. Open manual valves through the stripper reflux drier and around the stripper gas separator level control valve. Leave the stripper reflux pump discharge valve closed.
e. Open manual valves in crude tank recycle line and ready the still feed pump for operation.
f. Start the recycle flow from the crude tank hack through the stripper feed line.
g. Turn on steam to the stripper reboiler. Start up the reboiler according to the start-up procedure previously discussed.
h. Bring steam flow up to the control point gradually. The column and a large mass of packing must be heated up, so it will take some time before the full steam flow can be utilized. The desired steam flow will depend upon the plant production rate and stripper reflux ratio.
i. When the stripper vapor line comes up to approximately 183F and a level, rise occurs in the stripper gas separator, start the stripper reflux pump.
j. The stripper is now operating on recycle. tThe stripper should be operated in this manner until feed is available from the reactor gas separa tor.
SL 008612
CONFIDENTIAL: Subject to Protective Order^
of 14th Judicial NO.
5_13
k. When the proper operating level is reached in the reactor gas separator, start feed from the separator to the stripper. Once feed from the reactor gas separator is started the EDO recycle from the crude tank can be discontinued.
Check Points
a. Check the steam rate to the reboiler.
b. Check the stripper reflux pump for proper operation.
c. Check the reboiler level. Never start-up or operate with a low reborler level.
d. Check the vent system. Make sure the non-condensables are venting and not accumulating and building up pressure on the system.
e. Check to see that enough cooling water is on each exchanger.
10. Distillation Column: Refer to Figure 14.3, page 14.4, for the graph from which the proper reflux rate can be selected.
Start-tip Procedure
a. Make certain cooling water is on the still condenser and product cooler, and that steam pressure is available to the still reboiler steam valve.
b. Open the proper feed tray valve.
c. Open the manual valves on each side of the still reflux con trol valve ard back through the reflux pump to the reflux drum. Leave the reflux pump discharge valve closed.
d. Open the manual valves in the still feed line between the crude tank and the still. Leave the discharge valve on the still feed pump closed.
e. Check the still reboiler level. If the bottoms withdrawal valve was closed when the column was last shut down, the level should be above the sight glass. Lower the level to the top of the sight glass. If the rebeller level is low it will have to be'corrected with material from the crude tank.
f. Start Phopflex-L addition to the reboiler.
g. Turn on the steam to the still reboiler according to the reboiler start-up procedure. As the reboiler temperature starts rising the still p ressuie will come up. When a slight positive pressure is obtained, open the still vent line to bleed down my inerts. Close off the nitrogen pad line.
SL 008613
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
5-14
h. As the reboiler temperature comes up, the level will drop. If the level goes below normal operating level, add feed from the crude tank. Watch the reboiler level closely, as it can easily change during start-up.
i. Slowly raise the steam flow until it is approximately at the desired operating valve. The steam flow is automatically controlled by the temperature of the column bottom trays. On initial start-up the amount of reflux obtained can be used as a guide to the proper steam flow setting.
j. As the still vapor temperature comes up to 183F and a level rise is Indicated in the still reflux drum, start the still reflux flow. Be gin the flow at a low rate and increase it to hold a constant level in the reflux drum. The block valves around the level control valve should be closed, 'Increase the reflux until the proper flow for a 1:1 reflux ratio is obtained. Base the reflux ratio on the desired still output. Regulate the reboiler steam flow to hold a constant level in the reflux drum at this rate.
k. Close the still vent line after the temperatures are estab lished and open the nitrogen pad to the still condenser.
l. The still is now on total reflux with no feed withdrawal. When operating temperatures are essentially reached, put the steam controller on automatic control with the set-point at the temperature established by previous operations.
m. Start feed to the still from the crude tank. Slowly increase the feed until, it is equivalent to the output from the stripper.
n. As level builds up in the reflux drum start product withdrawal.
o. Make bottoms withdrawals from the reboiler to hold a proper operating level.
Check Points
a. Make certain cooling water is on the condenser and cooler.
b. When the still is in operation the nitrogen pad system should be in service.
c. Check the reboiler level.
Trouble Shooting
There can be many operating difficulties associated with distilla tion columns, particularly when they enter service for the first time. Such problems include flooding, entrainment and similar occurrences that interfere with proper fractionation. How can the operator recognize and correct these situations? Temperatures, pressures, and product purity are the diagnostic tools for the difficulties described.
SL 008614
CONFIDENTIAL:
Subject to Protective Order
of
14th
Judicial District Court -1145
5-15
You must have vapor pressure-temperature data on the materials being fractionated when you are operating distillation columns. Pressures (read on process gages) can serve as a temporary guide to performance when key temperature control is inoperable or not dependable. Grabbing samples from various trays for check analyses is another conventional technique for determining performance.
Operators should check the temperature profile across the column to be. certain that it is consistent with the anticipated pattern. Excessively high temperatures in upper parts of the column may indicate vapor bypassing, due to excessive velocities or inadequate liquid tray-loading. Insufficient liquid on trays can be caused by inadequate weir height or missing or leaky valves.
Note that inconsistent temperatures may not always indicate process upsets. Checking thermocouples or seeing that thermowells are proper ly installed can sometimes eliminate what at first appears to be a process problem. Be certain that thermocouple immersion liquids are provided where required and see that insulation is sufficient to stop heat leaks around thermo couples or thermometer bulbs.
Column flooding is most frequently confirmed by differential pressure readings. When much higher than normal ^p's prevail, particularly with fluctuation or surging, it is very likely that there is flooding. Typical techniques for "dumping" flooded columns are: withdrawing or curtail ing feed, dropping reboil heat, or temporarily increasing pressure.
Usual cause of flooding is excessive liquid downflow at high vapor loading. Plugged trays can also cause this condition. Too cold a feed can also result in flooding and poor column operation,
11* Rework Kettle: The rework kettle will be operated only periodically. Start-up Procedure
a. Close manual valves around the kettle so that it is isolated from all other process equipment.
b. Turn on steam to the kettle jacket. Set the steam pressure control valve at the desired pressure (5-10 psig).
c. Make certain the condensate trap is working. Bleed condensate and inerts from the steam jacket.
d. When the kettle temperature rises open the vapor line from the kettle to the reactor vapor space.
e. Using the dump tank pump, slowly add organic, to the kettle.
f. The EDC and lights will vaporize and be condensed in. the reactor condenser. This slight increase in the plant production rate will be handled without any problem by the automatic instruments.
SL 008615
CONFIDENTIAL:
noffS1S4th cJt utdoicPiarlotDecistivtreicOt rder
No. 91-II45
Court
5-16
g. When the kettle level drops and the vapor temperature from the kettle rises above 195F drain the tars to drums for disposal. Close the vapor line before draining. Make use of the two sight glasses (one lighted) on top of the kettle to monitor the progress of each batch.
h. When the kettle has been drained it is ready for more feed. Be careful during the draining operation because painful burns could result if operating personnel get splashed with the hot tars. Avoid breathing the vapors from the hot tars.
12, Bottoms Purification; The. following procedure should be used when starting up the. flasher.
a. Check to make sure cooling water is on the flasher condenser and steam is available to the. flasher reboiler steam valve.
necessary.
b. Be sure the reboiler is full of liquid. Adjust the. liquid if
c. Turn on steam to the flasher reboiler. Start up reboiler according to reboiler start-up procedure.
d. Using the N2 jet pull a vacuum on the system.
e. As the reboiler temperature comes up, the level will drop. Maintain a constant level by opening the feed valve. Watch the liquid level closely as there is no recirculation flow.
f. Slowly raise the feed flow to the desired rate.
g. As the condensate tank fills the vacuum that was pulled on the system will decrease. The reboiler temperature will increase.due to the increase in system pressure,
h. When the condensate tank is full pump its contents to the reactor dump tank for storage. A N2 pad will be used to transfer the flasher product from the dump tanks to the Per-Tri plant.
Note: As the condensate tank is pumped down the vacuum will be re-established on the system. A loss of vacuum indicates a leak which should be located and repaired to prevent air mixing with the hot organic vapors in the flasher system.
i. The flasher must be drained periodically to remove the heavy impurities which concentrates in the flasher bottoms. After draining the flasher will be restarted. Phosplex-L should be added to the flasher reboiler after each draining.
SL 008616
r'lM, V..C'CC,
o1 v1 "-r--f- '7 t i V
ljU J -\ ^
1 lr
of 14 th J'-- : ' Lio
.
!,
.
`.t
t;
j
Order ct Court
5-17
Check Points
a. Make sure noncondensables are not accumulating and building up pressure in the system.
b. Reboiler level.
c. Check feed pump and feed flow rate periodically.
13. Pre-Start-up Procedures--Purging, Drying, Filling: For the initial start-up, the vessels will contain air and moisture. The plant must be dried and purged before operations can commence. The following precedure is given for these pre-start-up operations, and will be applicable for initial plant operations after a long-term shutdown.
a. After the contractors have finished and turned the various pieces of equipment over to Operations, the Maintenance Department will go into each piece of equipment. At this time the equipment will be inspected and cleaned if necessary to remove such things as residual sandblasting sand, tools, or other kinds of trash.
b. When Maintenance completes their work and "buttons-up" the plant, a 30 psig air or nitrogen pressure test will be made to be sure flanges and other connections are not leaking.
c. After pressure testing, the pressure will be released at the low points in the system. The flow of pressurizing gas will be maintained until all possible low points have been purged. This will remove trapped water from the lines and equipment.
d. The pressure will be bled from the system and a gas sweep will be started through the plant. Dry air (instrument air) or nitrogen should be used for the purge gas. Start at the front end of the plant and work toward the back end. The purge gas will be exhausted at various places in the plant to allow each piece of equipment to be thoroughly purged with dry gas. It is preferable if the purge gas is heated. The reboilers can be turned on to facilitate the drying operation.
e. The chlorine and ethylene gas flow controllers can be checked out at this time.
f. The dry gas sweep will continue until it is ascertained that the plant has been completely dried. To check the degree of dryness of the plant, dew points will be measured on the exit gas,
g. The plant will then be completely purged with nitrogen to re move all air.
SL 008617
C011F1DENTI hk;
to protective Order
Sub je of 14 th''"judicial
Diotric t
Court
5-18
h. Begin filling the process equipment with EDC obtained from storage. Turn on pumps (follow pump start-up procedure) so that each line and process vessel is solvent-flushed. Wherever possible, the various pieces of equipment will be filled to the top to insure complete washing with EDC. For the EDC still, however, it is planned to cascade liquid from the top to the bottom.
i. Reboilers and condensers may be put into operation at this stage with the stills on total reflux or recycle. This is also an appropriate time to check-out and use the process instruments, so that operating personnel can familiarize themselves with the instruments and their actions.
j. After complete circulation, check the EDC for quality. If it is clean and only contains water, it will be circulated through the process drier in the stripper reflux line until the water content has been lowered to a satisfactory level (below 20 ppm). If the EDC solvent is not clean, it will be stored in the dump tank for eventual clean-up.
k. If the stripper and still are operated on total reflux during these flushing operations, the reflux receivers will have to be drained complete ly to insure that phase water is not trapped in them.
l. Start-up levels will now be established in all vessels with either the initial EDC charge or a new charge from storage.
m. The plant is now ready for start-up.
It is important that care is taken in the plant drying steps. Water is a very bothersome contaminant. Water will not only create offspecification product, but will cause equipment to corrode very rapidly.
After a long term shut-down, some of the procedure will have to be repeated. What steps are necessary will depend upon the nature of the shut-down. Any time it is necessary for a piece of equipment to be worked on, it will have to be drained and purged with nitrogen. After the repairs have been made, the piece of equipment that was opened will have to be dried and purged before it is put back on stream. Never put a piece of equipment on stream unless it has been purged with nitrogen and is absolutely dry.
SL 008618
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145 VI. SHUT-DOWN PROCEDURES
A. Overall Shut-Down Procedure
The following procedure will apply whether the plant is to be down for a short or long time. Certain procedures will not be applicable for the short term shut-down, and will be eliminated by the operations supervisor.
Shut-Down Procedure
1. Notify the liquefaction department of the intended shut-down.
2. Notify PCI via the Shift Engineer of the intended shut-down.
3. Lower the chlorine and ethylene flows stepwise, reducing chlorine flow rate first.
4. Stop chlorine flow to the reactor. Close the manual block valves around the flow control valves and at the spargers. (Stop methane addition to the vent system.)
5. Leave a slight flow of ethylene going to the reactor until the reaction has stopped and the reactor temperature begins to drop. Stop the ethylene flow and close the block valves around the flow control valve and at the spargers.
6. When the low level alarm sounds on the reactor gas separator, turn off the stripper feed stream. Shut down the reactor reflux and stripper feed pump. Close the block valves around the reactor reflux and stripper feed control valves.
7. Shut off the steam to the stripper reboiler. Close block valves around the steam flow control valve.
8. Shut off the stripper reflux pump when the stripper gas separator level is low enough to close the automatic level control valve in the reflux line. Close the block valves around the level control valve.
9. Begin a small purge of nitrogen through the system. This prevents the system from going under a vacuum.
10. Shut off the feed to the still and stop the still feed pump. Clos the block valves around the still feed flow control valve.
11. Shut off steam to the still reboiler. Close the block valves around the steam flow control valve.
12. Stop EDC product flow to storage. Close the block valves around the product flow control valve.
13. Shut off the still reflux and reflux pump. Close the block valves around the reflux flow control valve.
SL 008619
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
6-2
14. Hake sure the still nitrogen pad system is in service.
15. If a short-term shut-down is anticipated, leave all utilities such as cooling water and steam on.
16. If a long-term shut-down is anticipated, the still reboiler contents should be flushed to the bottoms storage tank with fresh EDC.
17. For a long-term shut-down, shut down all utilities in the follow ing order:
a. Refrigeration machine
b. Steam supply c,, Cooling tower system
d. Instrument air
e. Electrical system
B. Detailed Equipment Shut-Down Procedure
1. Ethylene System:
a. Lower stepwise the chlorine flow followed by the ethylene flow until the chlorine flow is zero. After a short ethylene purge stop the ethylene flow.
b. If ethylene continues to flow immediately close the block valves around the ethylene flow control valve.
c. Close all manual block valves in the ethylene feed line. This includes the control valve block valves and the valves in the sparger manifold.
d. Notify PCI that the ethylene system shut-down is complete.
e. During the shut-down maintain an ethylene pressure of at least 35 psig in the system up to the flow control valve.
2. Chlorine System:
a. Notify liquefaction of the shut-down and request that the lead operator stand by the chlorine pump to maintain the pump discharge pres sure at approximately 125 psig.
b. Open valves to allow the MC liquid chlorine feed to by-pass the EDC vaporizers.
SL 008620
Subjec f 14th JuNdoi.cia91l ~d1^I.i4s5tvreictOrCdeorurt
6-3
c. If a long shut-down is anticipated close the block valves in the liquid chlorine lines to the vaporizers. Shut off the steam to the vaporizer and let the chlorine pressure bleed into the reactor. When the pressure approaches the reactor bottom pressure close the reactor spargers. The final chlorine pressure will have to be bled to the sewer.
d. If a short shut-down is anticipated, the liquid chlorine lines and the steam supply will not have to be shut off. The FCV can be shut from the panel board. Just before the flow is completely off, close the spargers and a block valve on the PCV simultanepusly.
3. Reactor:
a. Shut down the feed gas systems as described above.
b. Be sure all sparger valves are closed to keep EDC from back ing into the feed lines.
c. When the reactor gas separator level starts to drop and the stripper feed decreases, shut off the stripper feed flow. Secure the manual valves around the stripper feed control valve.
d. When the reactor cools down and the reflux flow stops, close the manual valves in the reflux line and stop the reactor pump.
e. Turn on a small nitrogen purge to the reactor system. This will prevent a vacuum from occurring in the reactor and keep it air free.
f. Shut off the cooling water to the reactor and separator con densers after the reactor cools, if a long term shut-down is contemplated.
4. HC1 Stripper;
a. The stripper feed is turned off during the shut-down of the reactor. Proceed with the shut-down of the stripper at the time the feed is turned off. The block valves around the stripper feed control valve should be closed.
b. Shut off the steam to the stripper reboiler. Close the block valves around the steam flow control valve.
c. When the reflux flow control valve is essentially closed, shut off the stripper reflux pump and close the block valves around the control valve.
d. Shut off the cooling water to the stripper condenser after column cools down if a long term shut-down is contemplated.
5. Distillation Column;
a. When the level in the crude tank has reached the desired level shut off the still feed flow. Stop the still feed pump and close the block valves in the still feed line.
SL 008621
CONFIDENTIAL: Subject to Protective Order
Of 14th Judicial District Court No. 91-1145
6-4
b. When the level control valve in the product line closes, turn off the steam to the still reboiler. Close the block valves around the steam flow control valve.
c. Gradually reduce the still reflux flow to keep a constant level in the still reflux drum.
d. When the reflux flow is essentially off, close the flow con trol valve to keep a constant level in the reflux drum. (Stop TCP Addition.)
e. The nitrogen padding system should be in service to prevent a vacuum from forming.
f. Close all block valves in the product lines.
g. Shut off the cooling water to the still condenser and product cooler after the column cools (only if a long term shut-down is contemplated).
6. Vent Gas Refrigeration System:
a. When the reactor and stripper systems have cooled the refrig eration system may be shut down.
b. Stop the compressor.
c. Close the suction and discharge valves around the compressor.
7. Utilities;
a. Electrical System
The following procedures should be used when shutting down electrical equipment.
(1) Motors: Select the service to be shut down and operate the stop pushbutton, then open the 440 v. starter breaker at the motor control center.
(2) Motor Control Center: Remove all connected equipment from service as directed in a-1, then open the 440 v. A.C.B. on the metalclad switchgear unit.
(3) 440 v. Metalclad Switchgear: Shut down all motors and the motor control center as directed in a-1 and a-2, then open the transformer secondary breaker.
(4) 13.8V/440 Transformer: Shut down equipment as directed in a-1, a-2, and a-3, then open fused disconnect No. 0-304.
$L 008622
CONFIDENTIAL! Subject to Protective Order of 14th Judicial District Court
No. 91-1145
6-5
b. Steam Supply System: Ordinarily the steam headers to the equipment will be left on during a shut down with a small steam bleed through the system. However, if it becomes necessary to shut down the steam supply system simply close all manual valves in the supply system and then close the pressure reducer valves.
8. Cooling Tower System: When a long term shut-down of all cooling tower water users is anticipated (includes both EDC plants and the MC plant) the following shut-down procedure should be followed:
a. When the plant has cooled down and all heat sources have been turned off, shut off the cooling water pumps.
b. Shut off cooling tower blow-down.
c. Turn off treatment chemical addition.
d. Stop well water make-up flow,
e. Turn off pH meter.
f. Shut down the cooling tower fans.
9. Instrument Air System: If it becomes necessary to shut the instru ment air system down the following procedure should be followed:
a. Unload the compressor by turning the transfer switch to the "OFF" position.
b. Stop the compressor.
c. Turn off the cooling water to the compressor.
d. Turn off the cooling water to the aftercoolers.
e. Close the manual valves around the driers and shut off the reactivation timer.
f. Close the block valve above the air receiver.
10. Stack Seal: The stack seal shut-down simply involves shutting off the seal water.
11. Flasher: The following procedure should be used when shutting down the flasher.
a. Shut off the feed. b. Turn off the steam to the reboiler, c. Break vacuum with N2.
d. Shut off the condenser cooling water.
SL 008623
CON FI DFNTI.c.L : Subject to P rotective Order of 14th Judici a I District Court
No. 91-1145
6-6
C. Emergency Shut-Down of Equipment
In the event that trouble arises in the EDC plant that cannot be handled by normal operating procedures, it may be necessary to make an emergency shut-down of one or more pieces of equipment. Emergency situations may involve fire, explosion, vessel or line rupture, instrument air failure, electrical failure, water failure, steam failure, etc. Each emergency will dictate its own procedure to be followed and it should be handled accordingly. Following is an explanation of some situations that may arise and a general outline of what should be attended to:
1, Reactor: If an emergency arises in the reactor, the feed gases should be shut down. This can be readily accomplished with the feed stop switch on the panel board. This will shut off the feed gases and the reaction will stop as soon as the dissolved gases in the reactor are depleted. If possible, a manual valve should also be closed in each of the feed gas streams to insure complete shutoff of the gases.
If possible, the reflux stream should be left circulating until the reactor has cooled sufficiently to stop boiling. If it is necessary to shut off the reflux stream, the level in the reactor will drop until boiling stops. If possible, the stripper feed should be continued for a while in this case to prevent over-filling the reactor gas separator. The routine shut down procedure can then be followed for the rest of the plant.
2. Stripper: If difficulty arises in the stripper, the feed and the steam should be immediately shut off. The reactor feeds should be stopped as soon as possible after the stripper feed and steam are shut off.
If the emergency is such that it is possible, the stripper reflux should be left on until the stripper cools below the boiling point. This will increase the rate of cooling of the column. If necessary, though, this flow can be shut off at the same time as the feed. This will reduce the volume of liquor retained in the column which may be advisable under some conditions.
If it is important for the heat to be removed from the column as quickly as possible, the volume of steam retained in the reboiler can be relieved by opening the by-pass around the steam trap and bleeding the reboiler to the atmosphere. This will greatly speed up the removal of excess heat from the column.
After the stripper is secure, the routine procedure should be followed for shutting down the remainder of the plant.
3. Distillation Column: If an emergency shut-down of the still is necessary, the steam and feed should be shut off immediately. Again, the re flux can be used to cool the column and the reboiler can be vented if it is desirable. Immediate shut-down of the reactor is not as important here since a surge is available in the crude tank. After the still is secure, the rest of the plant can be shut down routinely as necessary or desirable.
SL 008624
CGI'S P I'3r"71 s
Subject to Protective Order of 14th Judicial wiserict Cour
No. 91-1145
6-7
4. Loss of Refrigeration: No particular emergency is presented if a refrigeration failure should occur. The refrigeration compressor should be secured if the source of trouble is not readily corrected. When the surge volume of liquid Freon is exhausted, the vent condenser temperature will rise and the plant will suffer a loss of EDC.
At this point the situation will have to be evaluated to deter mine if operation at a loss is warranted, or if the plant should be shut down.
5. Loss of Cooling Water: If for any reason the cooling water flow should be interrupted, it is necessary that all heat supplied to the plant be shut off immediately. This includes shutting off the feed gases to the reactor. As rapidly as possible, shut off the reactor feed gases, and shut off the steam to the stripper reboiler, the distillation column reboiler, and to the reactor dopp kettle.
The remainder of the plant should then be shut down until the flow of cooling water is resumed.
If the cooling tower fans should fail, it is still possible to operate the plant. The cooling water temperature will rise and a corresponding rise in the condenser and cooler temperatures will result. If operation were continued under these conditions, the plant would suffer a large loss of ethylene dichloride in the vent stream. If the source of trouble can be cor rected in a short time, it may not warrant shutting down the plant, but this operation should not continue for an extended length of time,
6. Loss of Steam Supply: If the steam supply should fail, all process streams should be shut down. This presents no particular emergency except for a level build-up in the stripper since the stripper feed cannot be vaporized and set forward. For this reason the reactor should be shut down and the stripper feed shut off as soon as possible.
7. Loss of Instrument Air: The loss of instrument air would immedi ately shut off most process flows in the plant. Manually shut down and isolate the plant equipment, closing block valves on all automatic valves to insure against leakage. Shut off all pumps as soon as possible to prevent continued running against a dead shut off. Make certain the reboiler steam supply is off. In general, all instruments "fail safe."
8. Loss of Electricity: The loss of electrical power will necessitate a rapid shut-down and isolation of all equipment. Some instrument air may be available for a brief period, but manual valves should be shut as soon as possible. Make sure steam to reboilers is shut off and the steam bled from the jackets.
SL 008625
of
lib jo 14 th
t 'o f"
J ud iciu 1
L ' _ 13 <-
? Order ict Court
No. 91 1.14 5
6-8
9. Fire, Explosion, Line Rupture: Under any of these cases, the first consideration is to save the personnel in the plant area; the second considera tion is to save the plant. REMEMBER THIS AND ACT ACCORDINGLY. The sprinkler system should be tripped (if it has not automatically) in case of fire or explosion.
In case of a chlorine line rupture, the area should be evacuted; the plant shut down. If an ethylene line ruptures, there may be danger of fire or explosion. Therefore, if safety permits the ethylene supply line should be shut off at the plant battery limits. In case of an EDC line rupture, the equipment will have to be isolated and the plant shut down if necessary.
SL 008626
VII. ANALYTICAL
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-U45
A. Sample Points
The 44 sample points in the No. 1 EDC plant have been numbered and are described in Table 7.1. Some of the sample points will not be used routinely but are included for possible special samples.
In describing a sample, always use the sample point number as well as its description. This information should always be recorded on the sample tag to preclude the possibility of a sample mix-up.
B. Control Samples
1. Sampling Schedule: The schedule of control analysis is shown in Table 7.2, This schedule will be revised as needed to take into account the experience gained in operating the plant.
When there is any indication of trouble in the plant, extra analyses will be required. Do not hesitate to run the required analyses, because the answers so obtained may save a lot of useless effort later on or will help in making the right process correction sooner.
2. Liquid Samples: All liquid samples for control analyses will be taken in 6-ounce polyethylene bottles previously cleaned and dried by the laboratory. The schedule given in Table 7,2 will be followed.
The sampling procedure will be as follows:
a. Obtain the proper clean, dry bottle and take it to the sampling station. Leave the lid tightly closed on the bottle.
b. Purge the sample line to remove stagnant liquid from the tap and thus provide a good, fresh sample of the process stream.
c. Remove the lid from the sample bottle and take the proper amount of sample. Put the lid back on quickly and tightly.
Special care should be used in keeping the sample and sample bottle from being contaminated with the outside moist air since most of the control samples will be for water in EDC.
3. Analytical Methods: The analytical methods used in the control tests are included in this manual beginning on page 7-8 . Table 7.2 gives the sample points and the analyses that will be run on the samples.
C. Laboratory Samples
1. Sampling Schedule: The determinations that the laboratory will make are indicated in Table 7,3. It will be necessary, usually, for the mid night operator to take these samples.
SL 008627
Sub3eel: of 14 th
roo - r
No. 9
Order ;; t Court
7-2
2. Sampling Procedures:
a. General
It is quite important that samples for water determination be handled carefully to avoid contamination* The process streams contain so little water that the slightest trace of water from an external source will cause an incorrect determination*
b. Technique
All lab samples (except for cooling tower water and gas samples) will be taken in a dry brown glass bottle* These bottles have been cleaned and dried by the laboratory. If for any reason a bottle is suspected to be con taminated it should not be used.
To take a sample purge the sample tap of material to com pletely replace stagnant liquid in the fittings and dead line portion* Remove the bottle cap and fill the bottle completely full* Recap the bottle immedi ately.
Be sure to attach a numbered sample tag firmly to the sample. On the sample tag place the description of the sample, date, time and sample point number.
c. Who Takes the Lab Samples?
It is important that a systematic approach be followed in taking the plant analytical samples. Assignments for lab sample taking are given in Table 7.3.
d. Composite Sample
A daily composite sample of the EDO product will be taken* The scheme devised to accomplish proper compositing is as follows:
(1) Each operator will be responsible on his shift for "dripping" product EDC continuously in the 2" glass-pipe collection chamber. (Collect approximately 6ne inch of liquid per hour.)
(2) The sample from the chamber will be transferred once per shift, at 6:30 a.m,, 2:30 p.m., and 10:30 p.m*, into the proper sample bottle,
(3) A numbered sample tag will be affixed to the sample bottle. The tag should show the sample point number and a description in cluding the shift, date and time*
(4) These samples will be taken to the laboratory by the midnight lead operator by 7:30 a.m*
(5) Make sure that the sample chamber is empty before the next shift sample is started.
SL 008628
Sub jec l l j
Order
of 14th Judicial District Court
No. 91-1145
7o
e. Gas Samples
Laboratory gas samples will be taken either in the pressurized ethylene container (for ethylene only) or in brown burettes in the case of vent gases.
D. Process Chromatograph
A semi-continuous on-stream process chromatograph has been provided to sample the off-gas from the separator condensers. A complete description of the chromatograph may be found in the operating instructions for the unit. The com ponents to be resolved will be ethane, ethylene, oxygen, and methane.
This relatively expensive instrument gives the operator an essentially continuous analysis of the vent gases. The amount of unreacted ethylene and oxygen in the vent stream are the most important of the chromatograph results. The unreacted ethylene will be proportional to the excess ethylene used in the reactor. The oxygen analysis is used to adjust the percentage of combustables in the vent stream so that the gas does not become explosive.
The chromatograph will be used as a guide in setting the ethylene excess at which the reactor will be operated.
SL 008629
Subject ;.,5
^ - - Order
of 14th Judicial District Court
No. 91-1145
7_A
Sample Point No.
1. 2. 3. 4. 5. 6. 7.
8. 9.
10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 27.1 27.2 28. 29. 30. 31. 32. 33. 34.
35. 36. 37.
38. 39.
40.
TABLE 1 SAMPLE POINTS FOR THE No. 1 EDO PLANT
Container Type*
A B B D E F**} d*** E
F** f D*** E
D D E E F** d*** F** p*** F**, D*** E E F**, D*** F**, d*** D
-
D F** d*** F**, D*** F** p**# F** ])*** F**, D***
D D D D F E F** j)*** D
F D D
E E
E
Sample Description
Ethylene Gas Feed Chlorine Gas Feed Chlorine Vaporizer Liquid Catalyst Solution No. 2 Reactor Off-Gas Stripper Feed No. 2 Reactor Condenser
Off-Gas Stripper Condenser Off-Gas No. 2 Separator Condenser
Off-Gas Separator Condenser Liquid Vent Condenser Liquid Vent Condenser Off-Gas Stripper Off-Gas Stripper Reflux Before Drier Stripper Reflux After Drier Still Feed Liquid Still Off-Gas Still Condenser Off-Gas Still Reflux Product Still Bottoms
Bottoms Storage Tank No. 1 Transfer Tank No. 2 Transfer Tank No. 3 Transfer Tank Product to Dock Storage Before Transfer Pump From Line at Dock Storage Dock Storage Tank Barge Loading Product Composite No. 2 Reactor Liquor Cooling Tower Water Stack Seal Effluent Stripper Bottoms No. 2 Reactor Liquor at
Sight Glass Well Water Make-Up to C.T. No, 1 Reactor Liquor No. 1 Reactor Liquor at
Sight Glass No. 1 Reactor Off-Gas No, 1 Reactor Condenser
Off-Gas No. 1 Separator Condenser Off-
Gas
Sample Tap Location
Sample Cabinet Feed Flow Control Valve Vaporizer Inlet Dump Pump Suction Reactor Condenser Inlet Reactor Pump Suction Separator Condenser Inlet
Condenser Vapor Outlet Condenser Vapor Outlet
Condenser Liquid Outlet Condenser Liquid Line Condenser Gas Outlet Stripper Condenser Inlet Reflux Pump Suction Reflux Filter Disch. Feed Pump Suction Still Condenser Inlet Condenser Vapor Outlet Reflux Pump Suction Composite Point Still Bottoms Pump Suet.
Dip Sample Dip Sample Dip Sample Dip Sample
Pump Suction
Dip Sample Loading Line Reactor Bottom C.T. Basin
Reboiler Bottom Sight Glass Bottom
Make-Up Stream Reactor Bottom Sight Glass Bottom
Reactor Cond. Inlet Separator Cond. Inlet
Condenser Vapor Outlet
SL 008630
Sample Point No.
41. 42. 43. 44.
Order s
14 th Judicial Li strict Court of
No. 91-1145
7-5
Container Type*
Sample Description
Sample Tap Location
F**, D*** F**, D***
B B
No. 4 Transfer Tank Crude Storage Tank Cell Gas Vaporized Chlorine
Dip Sample Dip Sample Before PCV FCV on Vaporized
Chlorine System
*Container Type
A - Pressure Cylinder B - Special-Lab Only C - Clear Bottle D - Brown Bottle E - Brown Burette F - Plastic Bottle
**Control Lab Sample
***Main Lab Sample
SL 008631
CO NFIDENTIAL:
008632
TABLE 7.2
SCHEDULE OF No. 1 EDC PLANT CONTROL TEST
Sample
CO
Pt. No.
Description
12 Vent Gas
Frequency 1/Shift
Determination & Method Composition $i-3C)
6 Stripper Feed
2/Shift
h2o (M-l) , Iron (M-2)
14 33
20
31
35
Pt. 12 Pts. Pt. Pt.
Stripper Reflux Stripper Bottoms Product Cooling Tower Water
Cooling Tower Make-up
Time to Run Sample Time to Run Sample Time to Run Sample Time to Run Sample
2/Shift
h2o (M-l)
2/Shift
H20 (M-l) , HC1 (M-4), Iron (M-2)
2/Shift
H20 (M-l) , HC1 (M-4), Iron (M-2)
2/Shift
Chlorides (M-313, pH (M-318) Chromate (M-315), Bets 107 (M-315A)
1/Shift
Chloride (M-313)
Shift 1
8:30 AM 9:30 AM-1:30 PM 10:30 AM-2:30 PM 10:30 AM
Shift 2 4:30 PM 5:30 FM-9 :30 PM 6:30 PM-10:30 PM 6:30 PM
Shift 3 12:30 AM 1:30 AM-5:30 AM 2:30 AM-6:30 AM 2:30 AM
Note: For start-up andfon special control situations. determinations such as water or HC1 will be done on a more frequent basis.
O
cn
i-- ctr
rr v--i* 3" O
O Cj rr
Z Ctt ft
o H- O
.o
H- "0
VO CD i--> I--* o
l rr r- o to h- O
co rr ui rr h-
rr c
r->* (1>
Et O
n&
o cu
C rt (1
rr
-i'j O'
S u b je G t CtOoN FPIDr oEtNeTcIAt iLv :e O r d e r 7-7
f4 tli J u d ic ia l D is tric t C ourt
^ No. 91-1145 SL 008633
Sample Pt. No.
30, 36
6
16
21
20
31 35
TABLE 7.3 SCHEDULE OF No. 1 EDC PLANT LABORATORY ANALYSES
Description Reactor Liquor Stripper Feed Still Feed Still Bottoms Product Cooling Tower Water Cooling Tower Make-up
Sample Day Tuesday Thursday Thurs day Tuesday Daily Wednesday Wednesday
Analyses GC, Fe, H2O, HC1, Tars, Sp.Gr. GC, Fe, H20, HCl GC GC, Fe, H20, HCl GC, Fe, H20, HCl CrO^, NaCl, SiO^, PO4, pH, Betz 107 NaCl, Si04
Note: For start-up and on special control situations, additional and more frequent samples will be necessary.
CON FID END IJVt i tive Order ,, strict Court
E. Analytical Control Test
7-8
The test procedures found on the next pages have been developed by the main laboratory. Occasionally changes will be made in these procedures. The new procedures should be substituted for the old ones to keep this manual up-to-date.
SL 008634
oUDjoct k o Pi'oc:. 11th Jiidinj .;i ] l^ibn No, 91-1145
EDC ANALYTICAL CONTROL TEST METHOD NO. M-l
Court 7-9
1. Test: Water in Ethylene Dichloride containing no FeClg,
2. Sample Point: No. 13 - Still Feed, No. 15 - Still Reflux, No. 9 Stripper Feed, No. 11, 12 - Stripper Peflux and No. 16 Production, No. 20, 21 - VG Feed.
3. Safety Precautions: Ethylene Dichloride is an inflammable liquid, and its vapors will form explosive mixtures with air. Keep it away from flames and sparks, and use only under hood. Wear safety glasses, appon and gloves when handling EDC.
4. Interference: Free chlorine and iron.
5. Precision: "tlO ppm.
6. Apparatus: Titration apparatus.
7. Reagents;
a. Karl Fischer Reagent. b. Methanol - Phenol mixture1.
8. Procedure:
a. Turn instrument switch to the "on" position. Drain the titration vessel Level with the drain spout. Make up the volume to the red mark on the vessel with alcohol. .This is probably one of the more critical steps in the procedure. The degree of conductance through the solution is a function of the ratio of EDC to alcohol. Thus, the end point is established experimentally and. is necessarily confined to a specific ratio. Failure to follow instructions in this step, therefore, may completely distort the true end point.
b. Add concentrated K.F, reagent until, by visual observation, the neutral point is approached. The K.F, visual end point should be a very light iodine color.
c. Stopper the vessel and finally adjust the solution to the exact neutral point by aid of the K.F, contained in the burette and the instrument end point. When the solution is neutral, the ammeter will register 12.
d. Pipette a 20 ml. sample. Make sure the pipette is dry. e. Before adding the sample, check the micro amme ter, Ihe needle should
be either on or to the right of 13 drifting towards 14. If the reading is left of 12, or has exceeded 14, the neutral point will have to be readjusted. Otherwise, add the sample and replace the stopper. The importance of the neutral point cannot be over emphasized. The tendency, of course, is to over neutralize. The procedure, incorporates a small over titration at the neutral point to allow the operator time to prepare the sample, etc., and normally, this excess is consumed by
SL 008635
Sub Of 14;
Method No. M-l (Continued)
7-10
atmospheric contamination before the sample is added. However, the instrument response at this point is weak, and it is easy to over titrate considerably, if a fine line is not emphasized as to the difference between being on 12 and somewhere to the left of 12. The same precaution should be taken regarding a drift beyond 14. In this case, the effect on the analysis is the reverse of that referred to above, but is equally critical. f. Add the sample, replace stopper, reset the burette and start the titra tion. The burette assembly is designed with a double stopcock between the K.F. reservoir and the titration vessel. The stopcock nearest the vessel should deliver approximately a drop per second. This is necessary to allow for the lag in the instrument response, so that the needle de flection will be smooth and not erratic toward the end point. The second stopcock is merely used in the "on" and "off" position for refilling the burette and delivery of reagent to the adjusted stopcock. Serious error will result if this arrangement is employed in any other manner. g. Turn the stopcock nearest the. K.F, reservoir to the "on" position in the direction of the adjusted sLopcock and allow the titration to con tinue, uninterrupted, until the needle of the ammeter coincides with 14, h. Close the stopcock nearest the reservoir. If the needle does not drift beyond a reading of L6 in 20 seconds, record the titration. If it does, readjust the end point in the manner just described, and time the neutral point a second time. If it is necessary to readjust the end point over three times, the apparatus is not working properly, and the situation should be referred to the main laboratory. i. ppm I^O = Final K.F. Titer x N x 40,000. j . Standardization of K.F. reagent, The main laboratory will be responsible for maintaining a standard solution of CH3UH and water in the plant laboratory. The water in the standard will be determined by the K.F. employed in the main laboratory, which, in turn, has been previously standardized against a weighted amount of water. The standard will bear a label stating the grams of water per 20 mis. of solution. The operator in the field will titrate a 20 mi, sample of the standard as described in the sample procedure above.
Normality = grams H2O per 20 ml. K.F. Titer
SL 008636
CONFIDENTIAL: Subject to Protective Order Of 14th Judicial District Court
No. 91-IUj
7-11
EDC ANALYTICAL CONTROL TEST METHOD NO. M-2
1* Test: Iron.
2. Sample Point: Number 15 - Still Reflux, No. 13 Still Feed and No. 16 Product EDC.
3. Safety Procautions: Ethylene dichloride is an inflammable liquid, and its vapors will form explosive mixtures with air. Keep it away from open flames and sparks. Use only under hood. Wear safety glasses, apron and gloves when handling EDC.
4. Interference: Not determined, 5. Precision: *0.05 ppm Fe.
6. Apparatus and Equipment:
a. 250 ml. separatory funnels. b. Separatory funnel stand. c. 100 ml. graduated cylinders. d. 50 ml. graduated cylinders. e. Glass funnels. f. 100 ml. volumetric flasks. g. Automatic 5 cc pipette. h. 50 ml, buret. i. Fisher electrophotometer equipped with 525-B filter.
7. Reagents:
a. Approximately 1:1 HC1. b. 2% Thioglycolic Acid. c. Approximately 6 N NH4OH. d. Distilled water.
8. Procedure:
a. Add distilled water to the 90 ml. calibration mark on a 250 ml. separatory funnel. (The separatory funnel is calibrated and marked to indicate volumes of 90 and 200 mis.) Add 10 mis. of 1:1 HC1.
b. Add EDC sample to the 200 ml. mark. c. Shake vigorously for two minutes, venting as needed. d. Place separatory funnel in rack and allow phases to separate. e. Drain EDC into waste container, leaving HC1 phase in funnel. f. Transfer the HC1 phase to a 100 ml. volumetric flask. g. Add 5 ml. Thioglycolic acid and mix. h. Add 10 mis, NH^OH, dilute to volume with distilled water and mix. i. Place sample in electrophotometer cell and obtain reading on Scale A.
SL 008637
Method No, M-2
Continued
CONFIDENTIAL:
Subject to Frotsetive Order of 14th Judicici; j. Dist rich Court
Wo. 91 -114h
7-
j. Read ppm Fe from calibration chart. k. For blank, add 10 mis. of 1:1 HC1 to a 100 ml, graduated cylinder
with a pipetter. Fill to the 100 ml. mark with distilled water. Four 50 mis. of this solution into a 100 ml. volumetric flask and begin with Step "h" of procedure,
9. Calculations:
Grams Fe from Calibration Curve x 10^ = ppm Fe Sample Size x 1,25*
* Approximate specific gravity of EDC,
SL 008638
Reading
0.5
1.0
1.5
2.0
2.5
3.0 3.5 4.0 4.5 5.0
5.5
6.0
6.5 7.0 7.5
8.0
8.5 9.0 9.5
10.0
10.5
11.0
11.5
12.0
12,5
r) N F1 D EM'P1 P. b
' :;-.r,Subduct
iva
o '!l i . i.4'5
Order Court
IRON CHART FOR ELECTROPHOTOMETER NO. 5011 EDO CONTROL TEST
7-13
ppm, Fe
0.02
0.05 0.07 0.09
0.12
0.14 0.16 0.19
0.21
0.23
0.27 0.28 0.30 0.32 0.35
0.37 0.39 0.42 0.44 0.46
0.49 0.51 0.53 0.56 0.58
Reading
13.0 13,5 14.0 14.5 15.0
15.5 16.0 16.5 17.0 17.5
18.0 18.5 19.0 19.5
20,0
20.5
21.0
21.5
22.0
22.5
23.0 23.5 24.0 24.5 25.0
PPm> :
0.60 0,63 0.65 0.67 0.70
0.72 0,74 0.77 0.79 0.81
0.84
0.86 0.88
0.90 0.93
0.95 0.97
1.00 1.02
1.04
1.07 1.09
1.11
1.14 1.16
Calculations: Grams Fe = Reading x 0.0000029 (Calibration Factor)
ppm Fe = Grams Fe x 10^
(by Wt.) Size Sample x 1.25
(50 Ml.)
(Sp. Gravity EDO)
SL 008639
tive Order strict Court
EDG ANALYTICAL CONTROL TEST METHOD No. M-3
7-14
1. Test: Orsat Analysis of Vent Gas for HOI,
^'"2 ant* Inerts.
2. Sample. Point: No. 6, 8
3. Apparatus:
a. 100 ml. brown gas bulb connected to a leveling bottle containing 150 ml. H2O + 1 ml. Ortho Tolidine.
b. Fisher orsat burette connected to leveling bottle containing ethylene absorbent.
4. Reagents:
a. Absorbent for ethylene. b. Ortho Tolidine.
5. Sampling and Procedure:
a. Purge 100 ml. gas bulb for two minutes. If possible, place the gas bulb in a vertical position. When removing the gas bulb from the purge line, disconnect the sample in this order: 1. Turn the stopcock on the exit end of the bulb to the off position. 2. Close the stopcock nearest the sample point. 3. Disconnect the sample bulb from the line. This procedure provides the sample, which is under a slight pressure. Allow the gas sample to come to ambient temperature. Establish the prevailing atmos pheric pressure by rapidly rotating the stopcock through the open position. The release of pressure will be evidenced by a hissing sound. Repeat the procedure, until this sound can no longer heard.
b. Attach leveling bottle containing 150 mis. water and 1 ml. Ortho Tolidine to the 100 ml. gas bulb. Be sure all air is out of rubber tubing, and connect to small end of gas bulb. Open the stopcock connecting the gas bulb and leveling bottle and allow the acid gases to dissolve. Shake gas bulb gently, until constant reading is obtained. Record this as % HC1.
c. Fill Fisher orsat burette with ethylene absorbent to a point above connecting rubber tubing. Open cocks in gas bulb and orsat burette.. With aid of water leveling bottle, transfer remaining gas to orsat burette. Close both cocks and disconnect orsat burette at ball joint.
d. Shake sample in orsat burette, until a constant reading is obtained. Record the mis. of gas left as inerts (i.e., 100 - reading).
e. Allow water in gas bulb to flow back into the leveling bottle. If no color is detected, record la CI2 (0.1).
SL 008640
CONFIDENTIAL:
Subject to Protective Order
- .T.irlirial District court of 14th
7-15
Method No. M-3 - Continued
6. Calculations: 100 - (% Inerts + 1 HC1) = % Ethylene Note: Change ethylene absorbent once/shift.
008641
SL
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
EDC ANALYTICAL CONTROL TEST METHOD NO. M-3A
1. Test: Orsat analysis of vent gas for HC1, C2H4, CI2 and unsaturated Organic gasess when operating with excess CI2 or when CI2 is found in vent gas.
2. Sample Point: No. 6, 8. 3. Apparatus:
a. 100 ml. brown gas bulb connected to a levelling bottle containing about 150 ml. of 1.0 N caustic.
b. Fisher orsat burette connected to levelling bottle containing ethylene absorbent.
4. Reagents:
a. Absorbent for ethylene. b. 1.0 N NaOH or 1.0 N K0H. c. Acetic acid d. 0.1 N Na2S203. e. Starch. f. KI crystals or 5% KI.
5. Frequency: Twice per shift, or as needed.
SL 008642
6. Sampling:
a. Purge 100 ml. gas bulb for two minutes. If possible, place the gas bulb in a vertical position. When removing the gas bulb from the purge line, disconnect the sample in this order: 1. Turn the stopcock on the exit end of the bulb to the "off" position. 2. Close the stopcock nearest the sample point. 3. Disconnect the sample bulb from the line. This procedure provides the sample, which is under a slight pressure. Allow the gas sample to come to ambient temperature. Establish the prevailing atmos pheric pressure by rapidly rotating the stopcock through the open position. The release of pressure will be evidenced by a hissing sound. Repeat the procedure, until this sound can no longer be heard.
b. Attach levelling bottle containing about 150 mis. 1 N NaOH to the 100 ml. gas bulb. Be sure all air is out of rubber tubing, and connect to small end of gas bulb. Open the stopcock connecting the gas bulb and levelling bottle and allow the acid gases to dissolve. Shake gas bulb gently, until constant reading is obtained. The reading obtained should be subtracted from 100 to give total acid gases which will be called B^.
Note:
If this value cannot be read on the sampling burette, transfer the gas to the measuring burette and read, before the following s tep .
Method ISo. M-3A - Continued
Subject to Protective Order or 14th Judicial District EciFr
No. 91-1145
c. Fill Fisher orsat burette with ethylene absorbent to a point above connecting rubber tubing. Open cocks in gas bulb and orsat burette. With aid of the levelling bottle, transfer remaining gas to orsat burette. Close both cocks and disconnect orsat burette at ball joint.
d. Shake sample in orsat burette, until a constant reading is obtained. Record the mis. of gas left as inerts (i.e., 100 - reading). Record ethylene as 100-(inerts)-(acid gases).
e. Acid gases; 1. Drain the NaOH contained in the levelling bottle and gas bulb into a 400 ml. beaker and add about 20 ml. of acetic acid, 2. Add a small scoop of KI crystals or 10 ml. of 5% KI solution. 3. Titrate the sample with 0.1 N Na2S203 to a pale straw color. Add one dropper of starch solution and continue titration, until the disappearance of the blue color,
7. Calculations:
a. From the chart obtain the mis. of CI2 equivalent to the titer. b. Mis. CI2 (from chart) = 7,, CI2. c. Total acid gases (B^) - L Cl2 = % HC1
Titer x .100 x .0355 = Titer x 1.20 ~ Mis. Cl2 .00295
SL Q08643
Titer (ml)
.4- 1.2 1.3- 2.1 2.2- 2.9 3.0- 3.7 3.8- 4.6 4.7- 5.4 5.5- 6.2 6.3- 7.1 7.1- 7,9 8.0- 8.7 8.8- 9.6 9.7-10.4 10.5-11.2 11.3-12.1 12.2-12.9
CONFIDENTIAL: Of "nhCJ,.'? Prt0ct1'' Order
ilth Juuidai District Court No, 91-1145
7-18
% CI2 in Vent Gas
Cl2 (ml)
Titer (ml)
ci2
1
13.0-13.7
16
2
13.8-14.5
17
3
14.6-15.4
18
4
15.5-16.2
19
5
16.3-17.0
20
6
17.1-17.9
21
7
18.0-18.7
22
8
18.8-19.5
23
9
19.6-20.4
24
10
20.5-21.2
25
11 30
36
12 40
48
13 50
60
14 60
72
15 70
84
0086A4
SL
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
EDC ANALYTICAL CONTROL TEST METHOD NO. M-3B
1. Test: Determination of Free Chlorine in Vent Gas
2. Samp1e: Vent Gas from Condenser (before addition of CH4)
3. Interferences; Other Oxidizing Agents
4. Apparatus and Reagents;
a. Manometer - (previously calibrated)'*' b. 1000 ml. Bubbling Jar c. 500 ml. Porcelain Casserole d. Stirring Rod e. 57, KI f. 0.01N Na2S203 g. Starch Solution Indicator h. Burette, 10 ml., Automatic "0"
5. Procedure:
a. Purge vent gas for several minutes and then reduce flow. Cut off flow with small needle valve and connect to right side of the manome ter.
b. Connect the bubbling jar containing approximately 200 mis. 5% KI to the left side of the manometer.
c. Adjust gas flow to a 2" differential on the manometer. Bubble gas for 5 minutes.
d. Record temperature of gas and bubbling time and close needle valve. e. The reddish-brown KI solution is titrated with 0.01N Na2S203
in the Casserole until a straw-yellow color is reached. f. Two droppers of starch solution are added and the titration is
continued until a clear end point is reached.
6. Equations:
Cl2 + 2KI ----- 2KC1 + 12
12 + Na2S203----- Nal
(Colored)
(Clear)
1. Manometer orifice set at time of calibration - DO NOT TAMPER.
SL 008645
Method No. M-3B - (Continued)
CONFIDENTIAL: Subject to Protective Order of 14th Judicial Distn ct Court
No. 9l"il4!3
Calculations: a. g Cl = Titer x Normality x 0.03545 b. Meq Cl2 = g Cl/0.0709 c , ml CI2 = meq CI2 x 22.4 = Vi
2
d. ml vent gas = 114,500 x 273 x t (Minutes) 60 x 273 + Temp. (Degrees F)
e * x 100 = % Cl2 by volume
V2
8Typical Results: Trace to 0.1% CI2
V2
2. 114,500 ml. gas vent/hour at 0F using HC1 as standard
SL 008646
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Cbtagft
No. 91-1145
EDC ANALYTICAL CONTROL TEST METHOD NO, M-3C
1. Tes t; Orsat Analysis for HCl, C02s 02 and C2H4. In Vent Gas
2, Sample Point; Nos , ( and 8
3. Appara1tus;
a. 100 ml. brown gas burette. b. Leveling bottle. c. Orsat apparatus with absorption chambers for CO2, O2 and C^H^.
4. Reagents;
a. Confining Solution b. C02 absorbant (29% KOH) c. 02 absorbant (Pyrogallic Acid) d. 02H^ absorbant (HgSO^ in H2 SC^)',
5. Procedure:
a. Connect 100 ml. gas burette to sample tap and purge for two minutes. If possible, place the gas bulb in a vertical position. When removing the burette from the purge line, disconnect the sample in this order;
(1) Turn the stopcock on the exit end of the burette to the off position.
(2) Close the stopcock nearest the sample point. (3) Disconnect the sample burette from the line. This procedure
provides the sample, which is under a slight pressure. When ready to run the test establish atmospheric pressure in the burette by rapidly rotating the stopcock through the open position. The release of pressure will be evidenced by a hiss ing sound. Repeat the procedure, until this sound can no longer heard.
b. Attach the leveling bottle containing 150 mis. of confining solution to the burette. Be sure all air is out of the rubber tubing and con nect to the small end of the burette. Open the stopcock connecting the burette and leveling bottle and allow the acid gases to dissolve. Shake the burette gently, until a constant gas volume reading is ob tained. Record this reading as "A".
c. Transfer the remaining gas to the measuring burette of the orsat apparatus. (Be careful not to allow air to enter the system.)
d. Pass the residual gases through the C02 absorbant chamber slowly and back to the measuring burette until a constant volume reading is obtained. (This will take at least 10 passes.) Record the new volume reading as "B".
e. Pass the remaining gas through the 02 absorbant chamber and back to the measuring burette until a constant reading is obtained. Record this reading as "C".
SL 008647
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
METHOD NO. M-3C (Continued) f- Pass, the remaining gas through the C2H4 absorbant chamber and back to the measuring burette until a constant reading is obtained. Record this reading as nD!l.
6 Calcu1 a tions: a. % HC1 = 100 - "A" b. % C02 = !:A" - !IB" c. % 02 = "B" - C'! d. % C2H4= "C" - MD"
SL 008648
CONFIDENTIAL: ^Subject to Protective Order or 14th Judicial District Court
No. 91-1145
EDC ANALYTICAL CONTROL TEST METHOD NO. M-4
1. Test: Acidity as HC1, ppm.
2. Sample Point: No. 13, 16.
3. Safety Precautions: Ethylene dichloride is an inflammable liquid, and its vapors will form explosive mixtures with air. Keep it away from flames and sparks. Use only under hood. Wear safety glasses, apron and gloves when handling EDC.
4. Interference: None.
5. Precision: 1*0.10 ppm HC1.
6. Apparatus:
a. 250 ml. separatory funnel. b. 250 ml. beaker. c. 10 ml. microburette, d. 100 ml. graduated cylinder.
7. Reagents: 0.01 Sodium hydroxide.
8. Procedure:
a. Add 100 ml, of sample toa 250 ml.separatory funnel. b. Add 100 ml. of distilledH2O to funnel andagitate thoroughly
one minute. CAUTION: Release pressure in funnel by venting as required. c. Allow to separate into two layers. Drain bottom layer (EDC) into second 250 ml. funnel. Drain top layer (H2O + HC1 into 250 ml. beaker. d. Add phenolphthalein indicator and titrate with .01 N caustic to a permanent light pink end point. Record the titration to nearest .01 ml. e. If the titration requires more than 1.00 ml. of NaOH, the extrac tion procedure should be repeated using the sample retained from (Step 8c) and 100 ml. distilled H2O. This second titer should be added to the one obtained in (d).
9. Calculations:
a. Total mis. NaOH x N x .0365 x 10^ = ppm HC1 100 x SP. Gr. EDC (1.25)
mis. NaOH x 2.92 = ppm HC1
b. Locate total mis. NaOH used in titration on chart and read ppm HC1.
c. If the FeCl2 exceeds 1.0 ppm, the following correction should be made. Subtract 1.8 ppm HC1 for every ppm Fe.
SL 008649
1
CONFIDENTIAL: Subject to Protective Order of 14th Judicial r ' i. ict Court
No. 91-1145
CHART FOR DETERMINATION OF HC1, ppm
7-24
Mis WaOH
0.33-0.35 0.36-0.39 0.40-0.42 0.43-0.46 0.47-0.49 0.50-0.53 0.54-0.56 0.57-0.59 0.60-0.63 0.64-0.66 0.67-0.70 0.71-0.73 0.74-0.77 0.78-0.80 0.81-0.83 0.84-0.87 0.88-0.90 0.91-0.94 0.95-0.97 0.98-1.01 1.02-1.04 1.05-1.07 1.08-1.11 1.12-1.14 1.15-1.17 1.19-1.21 1.22-1.24 1.25-1,28 1.29-1.31 1.32-1,35 1.36-1.38 1.39-1,42 1.43-1.45 1.46-1.48 1.49-1.52 1.53-1.55 1.56-1.59 1.60-1.62 1.63-1.66 1.67-1.69 1.70-1.72 1.73-1.76 1.77-1.79 1.80-1.83 1.84-1.86 1.87-1.90
ppm HC1
1.0
1.1
1.2
1.3 1.4 1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.3 2.4 2.5
2.6
2.7
2,8
2.9 3.0 3.1 3.2 3.3 3.4 3,5 3.6 3.7 3.8 3.9 4.0 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5.0 5.1 5.2 5.3 5.4 5.5
Mis NaOH
1.91-1.93 1.94-1.96 1.97-2.00 2.01-2.03 2.04-2.07 2.08-2.10 2.11-2.14 2,15-2.17 2.18-2.20 2.21-2.24 2.25-2.27 2.28-2.31 2.32-2.34 2.35-2.38 2.39-2.41 2.42-2.44 2.45-2.48 2.49-2.51 2.52-2.55 2.56-2.58 2.59-2.61 2.62-2.65 2.66-2.68 2.69-2.72 2.73-2.75 2.76-2.79 2.80-2.82 2.83-2.85 2.86-2.89 2,90-2.92 2.93-2.96 2.97-2.99 3.00-3.03 3.04-3.06 3.07-3.09 3.10-3.13 3.14-3.16 3.17-3.20 3.21-3.23 3.24-3.27 3.28-3.30 3.31-3.33 3.34-3.37 3.38-3.40 3.41-3.44
ppm HCl
5.6 5.7 5.8 5.9
6.0
6.1
6.2
6.3 6.4 6.5
6.6
6.7
6.8
6.9 7.0 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9
8.0
8.1
8.2
8.3 8.4 8.5
8.6
8.7
8.8
8.9 9.0 9.1 9.2 9.3 9.4 9.5 9.6 9.7 9.8 9.9
10.0
Method No. M-
SL 008650
CONFIDENTIAL: subject to Protective Order of 14th Judicial Dis^-ti ct Court
No. 91~H45
EDC ANALYTICAL CONTROL TEST METHOD NO. M-5
7-25
Test; Determination of Catalyst (FeC^) Concentration in Reactor Liquor.
2. Sample Point; No. 22.
3. Abstracts This method was devised for the rapid determination of catalyst concentration in the EDC reactor. The method involves the extraction of ferric chloride from the sample with hydrochloric acid, followed by an iron analysis by the colorimetric thioglycolic acid method.
4. Applications EDC reactor liquor.
5. Interfering Substance; Not determined.
6. Procedure; Place 25 ml. approximately 1 N HC1 in a one liter volumetric flask. Add 10 ml. approximately 0.1 N NaAg02 to flask, then carefully pipette in 1 cc of sample. Mix the liquids thoroughly, shaking for at least 1 minute. Then sweep gaseous chlorine away by directing an air stream into the flask. Add 10 ml. 2% thioglycolic acid and mix. Make alkaline with approximately 6 N NH^OH, adding a few drops in excess. Dilute to volume and mix. Pipette 50 ml. aliquot and dilute to 100 ml. Determine grams of iron from a previously standardized Electrophotometer.
A distilled water blank will be adequate, unless the HC1 extract is colored by organic materials. If so, a blank may be run on HC1 extract, omitting the thioglycolic acid.
7. Calculations;
gm. Fe x 2.9049 = gm. FeCl3
gm. FeCl^ x 20 x 100 = per cent FeCl3 *1.25 g
*Approximate specific gravity of EDC.
SL 008651
CONFIDF.U
TlAh'-H f-y V- * 1
r
Subject to E'rot . : 1-- T
o l^th J^nlCljJ
ho,
Or tie i :t Court
EDC ANALYTICAL CONTROL TEST METHOD NO. M-6
7-26
1. Test: Check for excess moisture in ethylene feed.
2. Sample Point: No. 1
3. Apparatus: Alnor Dew Point Analyzer.
4. Procedure:
a. Turn off inlet valve, and depress button on top of ratio gauge. If ratio does not read exactly 1, adjust it by means of screw knob at bottom of ratio gauge.
b. Open inlet valve 1/4 turn, allowing purging to start again. c. Read temperature on thermometer on instrument, and determine
desired ratio by means of chart in cabinet. d. Close outlet valve, and pump pressure up to desired ratio. e. While observing expansion chamber through window on instrument,
depress plunger. f. If no fog appears, record moisture as less than 100 ppm wt. g. If fog appears, notify foreman or shift engineer.
ETHYLENE DEW POINT CHART
Temperature (F)
25- 29 30- 34 35- 39 40- 44 45- 49 50- 54 55- 59 60- 64 65- 69 70- 74 75- 79 80- 84 85--89 90- 94 95- 99 100-104 105-109 110-114
Ratio
.51 .48 .46 .44 .42 .39 .37 .36 .34 .33 .31 .30 .29 .28 .26 .25 .24 .23
SL 008652
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
EDC ANALYTICAL CONTROL TEST METHOD NO. M-6A
7-27
1. Test: Determination of Ethylene Purity.
2. Sample Point: No. 1
3. Apparatus:
a. One 100 ml. clear absorption burette. b. One 250 ml. leveling bottle.
4. Procedure:
a. Fill burette with ethylene absorbent or Burrell Sorbant "A" and allow to drain back into leveling bottle, keeping level in the burette above the bottom stopcock. This is done to remove all air from the rubber tubing.
b. Connect burette to sample point and allow ethylene to purge through burette for approximately 1-2 minutes.
c. Shut off bottom and top stopcocks, then needle valve in that order. d. Allow burette to reach ambient temperature and vent excess pressure. e. Open bottom stopcock and shake burette until no apparent absorption
is taking place. f. Read % ethylene from graduation on the burette.
SL 008653
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 91-1145
EDC ANALYTICAL CONTROL TEST METHOD NO. M-311
1. Test: Alkalinity. 2. Sample Point: No. 40, 41. 3. Apparatus:
a. 250 ml. beaker. b. 100 ml. graduated cylinder. c. Automatic 10 ml. burette assembly. d. Stirring rod. 4. Reagents: a. 0.02 N sulfuric acid. b. Methyl orange. 5. Procedure: a. Measure 100 ml. of cooling water into a 250 ml. beaker. b. Add .02 N sulfuric acid, stirring continuously, until the color
changes from green to yellow. c. (If chloride test is desired, save sample and begin with Step 2
under chloride test.) 6. Calculations:
ml. of Sulfuric Acid x .02 x .05 x 10^ = ppm as CaCO^ Sample Size
SL 008654
CONFIDENTIAL: of S1u4btjhecJt utdcicPiarlotDecistiUve-icOt rCdeorurt
No. 91-i 14 b
EDC ANALYTICAL CONTROL TEST METHOD NO. M-312
-29
.1 Test: Calcium and Magnesium as CaO.
2. Sample Point: Number 40, 41.
3. Apparatus:
a. 500 ml. porcelain casserole b. 100 ml. graduated cylinder.
.c Automatic 10 ml. burette assembly
d. Rubber policeman.
4. Reagents:
a. Versenate solution. b. Monover indicator. c, 1 N hydrochloric acid. d. Methyl red. e,, Ammonium hydroxide solution (6N).
.f Distilled water.
5. Procedure:
a. Measure a 100 ml. sample of cooling water into casserole and add 200 ml. distilled water.
b. Add 10 drops methyl red. c. Titrate with 1 N hydrochloric acid to the red end-point and add
exactly 2 ml. in excess. d. Stir gently for 30 seconds. e. Add 2 ml. of ammonium hydroxide solution and stir to mix. f. Add Monover indicator until the appropriate color develops. g. Add standard versenate solution, until the solution changes
from wine-red to pure-blue.
6. Calculations:
ml. Versenate Solution x .00056 x 10^ Sample Size
ppm Ca and Mg as CaO
SL 008655
EDC ANALYTICAL CONTROL TEST METHOD NO. M-313
,1
7-30
1. Test: Chloride.
2. Sample Point: No. 40, ,41.
3. Apparatus:
a. 250 ml. beaker. b. 50 ml. graduated cylinder. c. Automatic 10 ml. burette assembly. d. Stirring rod.
4. Reagents:
a. 0.02 N H2S04 b. 0.0282 N mercuric nitrate. c. Methyl orange. d. Diphenylcarbazone-bromophenol blue indicator.
5. Procedure:
a. Measure 50 ml. of cooling water and approximately 100 ml. distilled water into 250 md. beaker. Titrate with .02 N sulfuric acid using 5-8 drops methyl orange indicator. End point color is brass.
b. Add 1/4 dropper of diphenylcarbazone-bromophenol blue indicator. c. Titrate with .0282 N mercuric nitrate, until solution turns from
orange to wine.
6. Calculations:
ml. mercuric nitrate x .0282 x .05845 x 10^ = ppm NaCl Sample Size
ml. x 32.96 = ppm NaCl
SL 008656
COrrirEN'nAL:
to Protacti vo Order
Of 14th Judicial .
Court
No. 91-1145
7-31
EDC ANALYTICAL CONTROL TEST METHOD NO, M-314A
1 Test: Chlorine.
2. Sample Point: No. 40.
3. Apparatus:
a. Wallace and Tiernan Comparator. b. Chlorine color disc - chlorine residual range 0.1 ppm to 2.0 ppm, c. Sample cells with a 26 mm viewing depth.
4. Reagents:
Ortho-Tolidine Reagent; 1.35 gms. of Ortho-Tolidine dihydrochloride dissolved in 500 ml. of distilled H2O. Mix with 500 mis. of dilute HC1 made by mixing 350 ml. of distilled H2O with 150 ml. of concentrated HC1.
5. Procedure:
a. Select two clean comparator cells. b. Fill one cell to mark with water under test. c. Insert this cell in the right cell space of the comparator. c1 . Note: This cell, when filled to the mark with water under
test, compensates for color and turbidity. d. Add 0-75 ml. Ortho-Tolidine reagent to the other cell. e. Fill this cell to the mark with the water under test. f. Insert the cell containing the water and the Ortho-Tol idine
reagent In the left cell space of the comparator, Match, as closely as possible, the color developed in the left cell with the glass color standards by revolving the disc. When match has been made, take reading from upper left hand opening of comparator case.
6. Calculations:
ppm residual C12 read directly from comparator.
SL 008657
!-t : v-.' ormu* O _ . : "i>, i i; i rt CuufV
EDC ANALYTICAL CONTROL TEST METHOD NO. M-315
7-32
1. Test: Chromate.
2. Sample Point: No. 40.
3. Apparatus:
a. 250 ml. beaker. b. 50 ml. graduate. c. Automatic 10 ml. burette assembly d. Porcelain spatula
4. Reagents:
a. 0.01N Sodium Thiosulfate. b. KI crystals. c. Concentrated HC1. d. Starch solution.
5. Procedure:
a. Measure 50 mis. of cooling tower water into a 250 ml. beaker. b. Add 1 scoop of KI crystals. c. Add 2 mis. of HC1 and mix. d. Let stand without agitation for 2 minutes. e. Add 0.01N sodium thiosulfate until sample turns straw yellow
and then add 1 ml. of starch solution. f. Continue titration until blue starch compound disappears.
6. Calculations:
ml. of sodium thiosulfate x 0.01 x 0.0387 x 10^ Sample Size
ppm CrO^
SL 008658
- Order ict Court
EDC ANALYTICAL CONTROL TEST METHOD NO. 315-A
7-33
1. Test: Betz 107 Concentration.
2. Sample Point: No. 40.
3. Apparatus:
a. 250 ml. volumetric flask. b. 100 ml. graduated cylinder c. Automatic 10 ml. burette. d. Spectrophotometer.
4. Reagents:
a. 20% sodium carbonate. b. Distilled water c. Betz 107 indicator
5. Procedure:
a. Add 50 mis. sample to 250 ml. volumetric flask. b. Add 2 mis. Betz 107 indicator, shake and let stand for 1 minute. c. Add 10 mis. 20% sodium carbonate (Na2C03) and let stand for 3 minutes. d. Dilute to volume with distilled water. e. In a second 250 ml. volumetric flask prepare a blank of 10 mis. 20%
^200^ and 50 ml. sample and dilute to volume with distilled water. f. Zero spectrophotometer with blank using 650 mu "A" (red) filter or at
650 mu. g. Read sample on spectrophotometer.
6. Calculations: Read ppm Betz 107 from chart.
SL 008659
Reading
0 2
4
6 8
10 12
14 16 18
20 22
24 26 28
30 32 ,34 36 38
of U Lb. \\.; .
CHART FOR DETERMINATION OF BETZ 107 FOR C. T. H20 - EDC
ppm, Betz 107
0
4
8 12
16
20
24 28 32 36
40 44 48 53 57
61 65 69 73 77
Reading
40 42 44 46 48
50 52 54 56 58
60
62
64
66 68
70 72 74 76
Electrophotometer No. 5011
7-34
ppm, Betz
81 85 89 93 97
101
105 109 113 117
121
125 129 133 137
141'. 145 149 154
SL 008660
lC0NFIDE^IAI.;
Of 14th JutdoicPiarlotedcis'tivricOt -TCcJoefurt7-35
No, 91-1145 EDC ANALYTICAL CONTROL TEST
METHOD NO. M-316
1. Test: Phosphate.
2. Sample Point; No. 40 - Cooling Tower.
3. Apparatus and Equipment:
a. 100 ml. volumetric flask. b. 1 ml. pipette. c. 5 ml. pipette. d. 15 ml. pipette. e. Glass funnel. f. 41-H filter paper. g. Fisher Electrophotometer equipped with 650-A filter. h. Hot plate.
4. Reagents s
a. 1:5 nitric acid. b. 10% potassium nitrate. c,, Ammonium molybdate solution. d. Para-methylamino-phenol sulfate solution. e. Sodium acetate solution. f. Distilled water.
5. Procedures
a. Place 5 ml. of the filtered sample of cooling water in a 100 ml. volumetric flask.
b. Add 3 ml. of 1:5 nitric acid to the sample and dilute to approxi mately 50 ml.
c,, Digest on hot plate for 30 minutes. d. To the cooled sample add:
(1) 10 ml. of 10%, potassium nitrate. (2) 2 ml. ammonium molybdate solution. (3) 1 ml. of para-methylamino-phenol sulfate. e. Allow to stand five minutes. f. Add 5 ml. of sodium acetate, and dilute to 100 ml. g. Allow to stand three minutes. h. Place sample and blank in Electrophotometer cells, and obtain reading using 650-A filter. i. For blank solution, place approximately 50 ml. of distilled water and 3 ml. of 1:5 nitric acid. Begin with Step 3.
6. Calculation ;
grams PO4 from calibration curve x 10^ = ppm PO4 Sample Size
SL 008661
Subject C:!FiDSNT^l:
Of th Ju^j c,Parjotect i -? Ord er
No.
trict 91~1I45
Court
EDC ANALYTICAL CONTROL TEST METHOD NO. M-317
7-36
1. Test: Silicon.
2. Sample Point: No. 40 - Cooling Tower.
3. Apparatus:
a. 100 ml. volumetric flask. b,, 10 ml. pipette. c. Fisher Electrophotometer equipped with 650-A filter. d. 5 ml. pipette.
4. Reagents;
a. HC1 solution. b. Ammonium molybdate solution. c. Sodium sulfite solution. d. Distilled water.
5. Procedure:
a. Pipette 10 ml. of cooling water into a 100 ml. volumetric flask, and dilute to volume with distilled water. Mix well.
b. Pipette a 10 ml. aliquot of the dilution into a 100 ml. volumetric flask.
c. Add: (1) 5 ml. of HC1 solution. (2) 5 ml. of ammonium molybdate solution.
d. Allow to stand for one (1) minute. e. Add 10 ml. of sodium sulfite solution, and dilute to 100 ml. with
distilled water. Mix. f. Let stand one <(1) minute, but not over three (3) minutes. g. Place sample and blank in electrophotometer cells, and obtain
reading using 650-A filter. h. A blank is prepared using 10 ml. of the diluted sample, and all
reagents except the ammonium molybdate reagent.
6. Calculations;
grams of Sjp2 from calibration curve x 10^ = ppm Si02 Sample Size
SL 008662
Eubnc-; orf. 3.'H-k
EDC ANALYTICAL CONTROL TEST METHOD NO, M-318
7-37
Operating instructions for Beckman Model H-2 pH meter,
1. Apparatus: One Model H-2 Beckman pH meter.
2. Procedure:
a. Range switch should be in the neutral position. b. Temperature compensator knob should always be set at 27C. c. Meter needle should always coincide with check pointer; if not,
adjust with standardization knob, making sure range switch is in the neutral position.
3. pH Measurements:
a. With switch in the neutral position, rinse electrodes and beaker with sample to be run.
b. Make sure needle and check pointer coincide; adjust with standardiza tion knob if necessary.
c. Fill beaker half full with sample and switch to proper range. d. Allow needle to come to rest and take a reading. Then turn switch
back to neutral position. e. Rinse electrodes with distilled water and wipe with Kimwipes, f. Immerse electrodes in distilled water.
4. Precautions:
a. Keep range switch on neutral position whenever electrodes are removed, or lowered into solutions, then check to s-.-e if check pointer and meter needle coincide.
b. Calomel electrode should never be less than half full of saturated KC1 solution, and should be replaced if inner part is cracked or broken.
5. Standardization: Use procedure outlined on front of meter.
6. Replacement parts and solutions;
a. Glass electrode - Laboratory Stock No. 1074-G. b. Calomel electrode - Laboratory Stock No. 1074-G. c. pH7 Buffer solution - Laboratory Stock No. 6096. d. Saturated KC1 solution - Laboratory Stock No. 6350.
SL 008663
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. 51-11^5"
EDC ANALYTICAL CONTROL TEST METHOD NO. M-318-A
7-38
Operating instructions for the Taylor pH Slide Comparator.
1. Apparatus:
a. Taylor pH Slide Comparator. b. pH Slide - Range 5.2 to 6.8 (dhlorophenol red). c. pH Slide - Range 6.0 to 7.6 (Bromthymol bime).
2. Reagents:
a. Chlorophenol red indicator solution. b. Bromthymol blue indicator solution.
3. Procedure:
a. Remove the top from the base. Fill the three testtubes to the 5 ml. mark with the sample to be tested. Replacethem in the holes back of the three slots in the base.
b. To the middle tube, add 0.5 ml. of indicator solution (select solution for range expected) with calibrated dropper. (CAUTION: Avoid contact of the dropper with the sample.) Mix thoroughly.
c. Place the color standard slide (select proper range to match indicator solution) on the base. Hold the instrument toward a light. Move slide in front of the test samples until a match is obtained. Read pH directly from values on slide.
d. If match is not obtained, repeat Steps a, b and c using the other indicator and slide.
SL 008664
P;n1 jc t Lo Prcloct i v; o t 1 ! t h j r. -'i i c i ' ] [) i s t r i
d ;i t* Cf.iu.rrt
8-1
VIII. PRODUCT STORAGE FACILITIES
A. Storage Tanks
Six tanks are located north of the process area. Four of these have a capacity of 25,000 gallons each. The other two are 60,000 gallon capacity tanks. Two of the small tanks (No. 1 and the crude storage tank) and the two large tanks are used for product storage. The other two are used to store still bottoms from the EDC (still bottoms tank) and MC (No. 2) plant until they can be purified in the flasher system and sent to Per-Tri as feed.
Additional storage tanks are located at the dock storage area. These two tanks holding approximately 500,000 gallons each are used for final storage before barge boading.
The tanks are padded with nitrogen to give an inert gas for tank breathing which occurs during level and temperature changes in the tanks. This pad prevents a flammable mixture in the vapor space of the tank and prevents product contamination by damp air. This pad is maintained at 1.5 ounces pressure. A pressure vacuum relief valve provides for safety relief in event of pad system failure.
All storage tanks are equipped with a Varec float type level indi cator which shows the tank level to 1/16" on the outside of the tank. This reading will be used for product inventory purposes. The area transfer tanks also have their levels transmitted to the control building and indicated on the panel board. These are indicated in percent of tank capacity and are to be used only as an indication of the level each tank contains. The tanks have high and low level alarms.
All storage tanks are surrounded by a dike. The volume enclosed by the dike is more than enough to hold the contents of the tanks within it. The purpose of the dike is to confine the contents of the tanks, in the event of a rupture, and limit the area which is exposed to possible fires.
All lines entering the EDC storage tanks enter at the bottom. It is possible to generate a static electricity charge when a liquid is allowed to fall through a vapor space. All tanks and pipe lines are equipped with electrical grounds to eliminate the chancp for a potential to build up.
B. Product Lines
The EDC product goes from the process area to a header arrangement around the transfer pumps. The piping is arranged so that the product can be sent to either of the four transfer tanks. The header also serves as the suction manifold for the transfer pumps such that product can be transferred from either transfer tank to dock storage or the area shipping department. Care should be taken when pumping out of these tanks or switching production from one tank to another as off-spec product and inventory difficulties may result if a wrong valve is opened.
SL 008665
8-2
Several special arrangements at the transfer pump header allow a variety of transfer possibilities. The product from the No. 1 transfer tank can be pumped directly to the MC plant via the No. 1 still feed pump. The crude tank and No. 4 tank contents can be transferred directly to the docks or to Per-Tri as feed. In addition EDC can be transferred in either direction be tween the No, 1 and No. 2 plant transfer tanks.
The dock transfer line goes from the transfer pumps along the pipe rack to the Area B shipping building and across the Columbia Southern road. After crossing the road the line continues underground to the dock storage area where it enters both the dock storage tanks. A line comes from each of the dock storage tanks to the suction of the barge loading pumps. The inlet and outlet of the dock storage tanks are tied together through the barge loading pumps such that the contents of the tanks can be circulated.
EDC from the dock transfer line can be returned to th^ plant at the reactor, gas separator, or neutralizers for reworking purposes.
SL 008666
IX. CATALYST SOLUTION
CONF
Subject to Protect!Order Of 14th Judic -i-al District Court
No. 91-1145
9-1
A. General
The need for ferric chloride (FeC^) catalyst addition to the reactor will be determined by examinating laboratory analytical results of the FeCl3 content of the reactor liquid. The reactor will normally be operated with a FeClg concentration of 0.3 to 0.4 wt. %. When this value drops below 0.3% FeCl3, a catalyst addition will be necessary. This should occur only occasionally.
To add catalyst, a master mix is prepared (see Fig. 14.5) that will then be added to the reactor to raise the iron concentration to the desired 0.4 wt. % FeCl3 (see Fig. 14.4).
B. Preparation
When a catalyst addition is necessary, the quantity of FeCl3 needed to raise the concentration to 0,4%, is first determined by Figure 14.4. Figure 14.5 is then used to determine the amount of EDC needed for the master mix. Add the amount of EDC that is determined from Figure 14.5 to the rework kettle. This EDC is taken from the bottom of the reactor or the reactor recycle. After the EDC is in the kettle, line up the pump tank pump to pump from the bottom of the rework kettle back into the top. Start circulating the EDC and add the required catalyst through the kettle manhole.
C. Addition
After the catalyst solution is thoroughly mixed, it can be pumped into the reactor via the dump tank pump.
SL 008667
X. REACTOR DUMPING
confidential:
Subject: Of Ktl, Jc;".C;, P5?rfcti:p^ Order
No.
A i .!'
ct Court
10-1
A. Full Dump
In the event the contents of one of the reactors become contaminated, an emergency dump of a reactor is necessary; or, if a reactor requires dumping for maintenance purposes, the reactor liquor can be readily transferred to the dump tanks. There is a dump tank for each of the reactors. The dump tank capacities are approximately 10,000 and 6,000 gallons for number one and two tanks respectively. Since the normal reactor charges are 8772 and 3078 gallons (24 and 18 ft.) for number one and two reactors, the tanks will hold the full reactor charges.
To drain the reactor to the dump tank:
1. Open the valves between the reactor bottom and the dump tenjc ex cept the bottom reactor valve.
2. Provide a supply of N2 to the reactor to prevent pulling a vacuum on the reactor as it is drained.
3. Vent the dump tank to the reactor.
4. Open the bottom reactor valve and drain the reactor 4s much as possible by gravity flow.
5. Drain the reactor slowly to allow the dump tank to vent. Complete the dump by using the reactor dump tank pump.
B. Periodic Dump
It is anticipated that after an extended period of operation, the reactor liquid will accumulate a high concentration of tars and inactive catalyst. When this occurs, a purge stream will be withdrawn from the reactor to either the dump tank or the rework kettle. This material will be evaporated from the rework kettle into the No. 2 reactor vapor space to recover the EDC. The quantity of purge required or the frequency necessary will be dictated by operating experience. Past experience has shown a tar production of approxi mately 0.5 lbs./ton of EDC produced.
C. EDC Recovery
To recover the EDC, the reactor purge stream or any EDC requiring clean-up will be taken to the rework kettle from either the reactor or the dump tank. If the material was originally collected in the dump tank, the dump tank pump is used to make the transfer.
The following procedure should be followed when operating the rework kettle:
1. Fill the kettle to approximately the top edge of the jacket.
SL 008668
5 u tj j e; ol 14 t i i
'' i- Lrict Court,
10-2
2. Turn on the steam supply. A pressure control valve is provided for the rework kettle steam control.
3. Open the kettle vent line and boil the EDC out of the kettle into the No. 2 reactor vapor space. Here the vapor will be condensed and fed to the stripper with the normal reactor vapor stream.
4. As the temperature of the vapor line from the rework kettle climbs above 185-195F, turn off the steam to the kettle and close the vent line. The tars in the bottom of the kettle can then be dumped into drums for disposal. Be sure to dispose of these tars while they are hot and non-viscons. Do not let tars cool and harden in the kettle.
SL 008669
Sub j'-'C -
al SistL-ict Court
of 14tli Juuj.1No
91-1145
ll-i
XI. SAFETY FOR THE ETHYLENE DICHLORIDE AREA
A. General
Due to the nature of the operation and the chemicals involved, the Ethylene Dichloride Area is restricted to authorized personnel only,
Company vehicles will be permitted to travel the main approach road during normal operations. Special permits will be required for vehicles to enter any of the other areas in this department.
The control building is pressurized for safety precautions, therefort it is to be utilized by authorized personnel only,.
B. Definitions
Some of the terms used in the following discussion are defined below
1. Flash Point: The flash point of a solvent is the lowest tem perature at which vapor is given off in sufficient quantities so that the vapor-air mixture above the surface of the solvent will propagate a flame away from the source of ignition. It is the temperature be Low which a solvent may be stored in open containers without formation ol an explosive vapor-air mixture.
2. Explosive limits; When combustible vapor is mixed with air in the proper proportions, ignition will produce an explosion. The vapor-air mixture which will form this proper proportion is called the explosive range The explosive range includes all concentrations of a mixture of flammable vape or gas in air in which a flash will occur or a flame will travel if the mix Lul ls ignited The lowest percentage at which this occurs is the lower explosive limit, and the highest percentage is the upper explosive limit
Explosive limits are expressed in percent bv volume of vapor in in
3. Maximum Allowable Concentration (MAC); Maximum allowable concen tration lor a material is the maximum concentration ot that material that can be tolerated t>y personnel lor a continuous 8-hour exposure with no ill efieits
C. Chemicals inthe EDC Area
The chemicals encountered in manufacturing ethylene dichloride, are listed below:
1. Chlorine
2. Ethylene 3. Ferric Chloride 4. Caustic Soda 3, Calcium Chi or iila
SL 008670
c;:1 6. Sulfuric Acid
. : i rj ct. Court Co, 91-o 125
11-2
7. Natural Gas (Methane)
H. Inert Gases (Nitrogen)
9. Freon-** /X
10. Ethylene Dichloride (EDC)
11. Hydrogen Chloride
12. 1,1,2 - Trichloroethane (TCE)
13. Sym. and Unsyra. Tetrachloroethane.
Some of the properties and safety hazards of these chemicals are given on the following pages.
SL 008671
Sub je<
i-r-L.c- ;;'.vc Order
Of 14th Judicial District Court
No. 91-1145
11-3
NAME; Chiprint
FORMULA.; C!?
MOLECULAR WEIGHT: 70.91
B0I1ING POINT: -30.1F
MELt'INC POINT: -J.49.8('F
VAPOR PRESSURE: (< 2 1. 9G, / , 7 60 mm. Ilg,
LIQUID DENSITY:
25l,C, 1,391 g./ec
RELATIVE VAPOR DENSITY: 2.45 (Air = 1.0)
FLASH POINT- None
EXPLOSIVE LIMITS: None
MAX. ALLOWABLE CONC.: 0.35 to 2 ppm DETECTABLE ODOR CONC.: 3.5 ppm
SL 008672
HAZARDOUS PROPERTIES: Chlorine is an extremely powerful respiratory irritant. Because of its pungent odor and irritating effect, traces of chlorine lti air are readily detected. Chlorine, is not poison, but kills or burns tissues. It has no cumulative effect nor does repeated exposure produce immunity. in an atmosphere containing chlorine, short, shallow breath ing should he used.
liquid chlorine and high concentrations of gas in contact with the skin will cause irritation and blistering of Lhe exposed area. Clothing contaminated wiLb liquid chlorine should be removed immediately and tiie exposed areas flushed with water.
TREATMENT: Remove the person from the contaminated area and call lor help or have the person report to First Aid, depending upon the severity of Lite circumstances. Administer arlifical respiration if necessary.
Clothing contaminated with chlorine should be removed immediately and Lhe exposed areas washed thoroughly with water.
All persons working with chlorine should be acquainted with the proper methods of handling this commodity, the use of gas masks, and emergency procedures.
Chlorine leaks can be located by wetting the suspected area with
ammonia water. Dense, white fumes will indicate the point of leakage.
Leaks must be given immediate attention because they become progressively
worse. If the leak is extensive it should be reported so that persons in
the path of the fumes can be warned. Chlorine is about
times as heavy
as air; therefore, it collects in low spots and stays near the ground.
NAME; Ethvlune
COSFIDS!!TiALl Subject to Protective Order Of 14th Judicial District Court
No. 91-1145
11-4
FORMULA: CH2CH2
MOLECULAR WEIGHT- 28.052
BOILING POINT: -155F MELTINC POINT: -272,9F
VAPOR PRESSURE- (3 8.9C., 58,000 mm. Mg.
LIQUID DENSITY: Normally a Gas
RELATIVE VAPOR TENSITY. 0,,98 (Air = 1.0)
FLASH POINT: None
EXPLOSIVE LIMITS: 37 to 347,
MAX. ALLOWABLE CONG.: 100 to 500 ppm
HAZARDOUS PROPERTIES: Ethylene is a flammable gas, T.t is a dangerous ex plosive hazard upon exposure to heat or flame. Carbon dioxide or dry chemical fire extinguishers should be used to put out an ethylene fire.
Ethylene is a colorless gas, but can be detected by its character istic sweetisn odor. It is nut toxic but will result in asphyxiation by depleting the oxygen content of the air.
1REATMEN1, A person ihat has been exposed to ethylene should be removed from the contaminated area. Administer artiiical respiration if necessary.
SL 008673
N AML Ferric Chloride
CCNFISSNTIAL! Subject +ton Pr-Lrotective Order Of 14th Judicial D;strict Court
No.
FORMULA: 1 0CI3
MOLECULAR WEIGHT: 162.22
BOILING POINT: 606.2F
MELTING POINT: 539., 6F
VAPOR PRESSURE: @ 194c\:, 1 mm. Hg.
DENSITY: (3 11C, 2.804 g/cc
1 LASH POINT* None
EXPLOSIVE LIMIT; None
SUBLIMATION POINT; 572F
HAZARDOUS PROPERTIES: Handling ferric chloride presents no particular problem It will seriously stain clothing and skin so it is advisable to wear pro tective clothing when handling it.
In case of eye contact, flush immediately and thoroughly with water and then rinse with a weak solution ot sodium bicarbonate or boric acid, A physician should be consulted in such cases.
SL 008674
NAME: Caustic Soda (Sodium Hydroxide)
lU'lAL: Sub'j-c-t ts Protective Order Of 14th Judicial District Court
No. 91-1145
11-6
FORMULA: NaOH
MOLECULAR WEI CUT: 40,0 1501 LINO POINT: 2 5'34E
ME l,T I NO POINT: b05r VAPOR PRESSURE: o' 71dC, 1 mm. Hg.
FLASH POINT: None EXPLOSIVE LIMITS: None MAX. ALLOWABLE CONG.: 2 mg./m.3 of Air
HAZARDOUS PROPERTIES: Caustic attacks any body tisane upon, contact, '] !> degree of injury depends upon the extent and duration of" contact and the temperature and concentration of the material. Caustic solution is de tectable by a siipperv feeling such as that of soapy water., Its cor rosive action on tissue causes burns and frequently deep ulceration, with ultimate' scarring. Contact with the eyes rapidly causes severe damage.
TREATMENT: immediately remove all contaminated clothing and equipment, then Hush the exposed area thoroughly with an abundance of water. If caustic contacts the eyes, they should be irrigated immediately with an abundant amount of water for at Least 15 minutes. Hold the eyelids apart during irrigation. The eve should then be washed with a mild saline solution; if such solution is available. Wash the eye with water for an additional 15 minutes. A physician should be seen immediately after the eye is thoroughly was lied.
SL 008675
n! AMI * lid i c i mi: ('hlntidi' FORMULA: CaCl? MOLECULAR WETOUT; 110,99 BOILING POINT; 2912F MELTING POINT: 1422]DENSITY . 2,512 g/cc ^ 252 FLASH POINT: None EXTLOSIVE LIMITS None
3VAJLs
Subject to PeDte
.'-.ft.
Of 14 th Jud2 c,i,?."
fia . t . . i
1l
SL 008676
Order ict court
NAME: Sulfuric Ac id FORMULA: u2S04 MOLECULAR WEIGHT: 98.08 BOILING POINT: 626F MELTING POINT- 50.9F VAPOR PRESSURE: <M 146C, 1 mm. Hg. LIQUID DENSITY: <a 25C, 1.83* g/cc FLASH POINT: None EXPLOSIVE LIMITS; None MAX. ALLOWABLE CONG,: I mg./m.3 of Air DETECTABLE ODOR CONC.; 0.12 ppm HAZARDOUS PROPERTIES: The greatest hazard of sulfuric acid is physical con
tact. Because of its affinity for water, it dries tissue; creating heat, and resulting in a painful slow healing burn. Repeated skin contact with diluted sulfuric acid solution can cause dermatitis.
Sulfuric acid reacts with water to produce heat. The acid should always be added to water upon dilution, never vice versa. TREATMENT: Immediately remove all contaminated clothing and equipment. Iiush the exposed area with an abundance of water. After thorough irrigation with water, applications of mild alkaline solutions may be used. Do not apply oils or ointments to burned area without mstrue tionaffrcm a physician. If the eyes are involved they should be immediately irrigated with water for at least 15 minutes. Report to First Aid for further treatment if necessary.
SL 008677
\ML; Methane ORXULA: CHzk4, MOLECULAR WRIGHT:
Dttir3 g 14 th Judic
No.
V
16,04
1 1-9
BOILING POINT: -258.7F FREEZING POINT: -297.8F
'LAP OR PRESSURE-
*82,1C, 34,900 mni. Ug .
RELATIVE VAPOR DENSITV: 0.555 (A:: r l. 0) FLASH POINT: None
EXPLOSIVE LIMITS: 5.3% to 14.0%
DETECTABLE ODOR CONC.: Odorless
HAZARDOUS PROPERTIES: Methane is a simple asphyxiant and a dangerous fire and explosion hazard. Methane fires should be fought with carbon
L dioxide or dry chemical extinguishers.
SL 008678
NAME'
Froon-2?
CON-lDKHTi:>L: Subject to Protective Order Of 14th Judicial District Cour^"-^
No. 91-1145
(C'h iorod i florome thane)
FORM: l LA- ClHtT.,
MOLECULAR WEIGHT: 85 .,46
iU)3 LING POINT: -41.4F
MLL1' 1 NO 1'0'iNi r TUL 8l'p VAPOR PRESS'LL: A?4lV 7,5(10 mm. He
RELATIVE VAPOR DENS] IV: 3 3/ ('Air = 1.0)
FtASH POINT.: None
EXPLOSIVE LIMITS. Nonc-
XAX, ALLOWABLE CONG.- Unknown
OETEC TABLE ODOR CONG. Unknown
i TALAR DOES PROl'ERIIES Troon-22 is very dangerous when lu-ated Lo decomposition, It emits highly toxic fumes of chlorides and fluorides. Never allow open flames to come in contact with freon-22 oi auv vessels containing it
SL 008679
; ; , .. . . : .
v.- Order
of j.4ri; Judicial District Court
No* 91-1145
11-
'Ai'T' Ethvlene Bichloride (EDC) (1,2-Dichloroethane) F DR MU LA. CH9C1CII2C1
MCIKCULAR WKTCliT: 98,966 BJJLING POINT: 182.3!'
MELT ING POT NT: ~31.0F
V-M'OR PRESSURE: f'rf 29
, LOO mm. Hg.
LIQUID DENSITY: ^ 20bC, 1.257 g/ec
KELAT1VP VA)-OR DENSITY3.35 (-Air = 1.0) FLASH POINT; 18.3C open cut. F.Y'LOSTVE LIMITS: 6.2 to 15.97,
AX. ALLOWABLE GONC.1 50 ppm, 200 mg./m.^ of Air
P;; TEG! ABLE POOR LONG. : Much less Ilian "MAC"
SL 008680
!! AFAR DOES PROVEN'! l I'S: Ethylene dichloride lias a distinctive odor which gives warning oi its presence in relatively safe concentrations. it irritates the and upper respiratory passages,
Short eposeres t" nigh concentrations of ethylene dichloride cause irritation ol the eves, nose and throat, followed by dizziness, nausea, mental con)`.o-ion, depression, rapid pulse, and Joss of consciousness in severe case:..
Chronic poisoning, where exposure occurs over an extended period, may cause less ci appetite, nausea, low blood sugar levels, and possibly dermatitis if there has been skin contact.
Employees exposed regularly to ethylene dichlorido should be examined periodically by a physician acquainted with the occupational hazards in volved. Physical examinations should be required when anv svmpLoms of poisoning occur.
hmpLoveos who may be subjected to severe exposures to ethylene dichloride vapors shouLd be provided with eye and respiialorv protection,
RfAIMENT. Immediately remove all contaminated clothing arid equipment. All at looted areas should be washed thoroughly with water and soap. After washing, a:' liniment containing lanolin should be applied to replace the nafuiul -,ki: oils. For serious or persistent cases of skin trouble and ^igns or e:*t oral ized poisoning a physician should be consulted.
If F.'DC enters the eyes wash them promptly with copious quantities oi water for a: least 15 minutes. Medical attention should be obtained in all cases oi eye contact.
Subject: to f of 14th Ju'ddiiccxi al District Court
No. 91-1145
11-1?
A person showing symptoms ot L)C vapor poisoning should be promptly removed from the contaminated area. Ini case breathing has stopped arti ficial respiration should be started immediately. Oxygen should be administered if oxygen inhalation equipment and a qualified operator are available If the patient is conscious, hot tea or coffee may he given as a stimulant. A physician should be called at once.
fl KDC is swallowed vomiting should he induced at least Mine times lol lowed bs the admin i s t ra t i. n .>i a t ah 1 .spoon I u 1 ol i ps, n: salts.
Water, toam, cailum dioxide drv chemical .u coil- < l t i .u ii ! < ii d< should In used I e light e t lt\ loin dulileridc tins.
SL 008681
NAMF,, I1 \xl rogen Chloride TiRMULA- iiCl
of
District Cccrfc No- 9i -- i145
! I - 11
'>!.KGuAk WLIGHT:-; 36.47 TOILING POINT: -120.6F
"ILLTING POINT- -17 3. /T 7AP0R PRKSSMRF- <a 1/.8C, 3040 mm. Hg, LIQUID DENSITY: Normally a Gas R Hi A'I I UK, VAPOR ITNSTi'i, 1.2t>8 (Aii = l.tQ IT -ASH Po! N 1 : None
EXPLOSIVE i IN ITS: None
MAX, ALLOWABLE GONG. ; 10 ppm (for 10 Hr, Day'. DETECTABLE ODOR GONG.: Unknown
"BAZARPOPS PR0PFRT1ES; Anhydrous hydrogen chloride is a gas which has a corrosive action upon tnc skin and mucous membranes. It will cause rapid and severe burns and is particularly dangerous to the eyes. The vapors are irritating and wi.Jl drive yon away from the- contaminated area before they are dangerous to you.
Hydrogen chloride is not flammable. However, the gas is highly soluble in water lormtng hydrochloric acid which attacks most metals with tin' evolution eI explosive hydrogen,
1 R1A 1 NT N I ; 1 mined i at el v remove a! 1 contaminated clothing and equipment and
I lush exposed areas with large quantities ot water. No attempt should he mado to neutralize the acid with alkaline solutions. Report to First Aid i i iii ci'ssarv.
SL 008682
X4M1-
l.! J 1' r iuii loroet hane il'CI'l
StiDjecr Li. F-
Of 14th T.^r 7
Order
Judicial District CCouirifc l-i
No- 91-1145
! OKMV 1 A Cil< 1 -,c:ll .1! I
MiM.Kt V i AK Wi it'll 1
rn lr.
Hill I ;\i, |MiNTr 2'36,8K
i'kki-zim: iojm- ul'i
VAI'wk PRESS, Rh ,5 2 1 0lV., 22 nrm, hp.
lIQFID DENSITY' e! 23 l , L.4j)9 g/cc
Kr'IAllVF VAi'OR 1`lNSUYr 4b (Air - 1,07
" LAS P tY'.TN~ XV nr
:.X! 1 ;YS1\ 1 ' INTIS* None
MAX An.0WAr.il' (')N('...
21 to 100 pp.n
i.'!` li ( i AIOJ'1 ODOR LiONci, t nknown
ilAFAROOllS I'ROVERT 1 FS 1 i rtchoroethaue inn cause burns oi Lin eyes and has a hannlul el lent upon tin- liver. All contact with the eves anil skin s h on 1 ii ho a\aided This material should bo handled with caution, because i t s toxicologies 1 ruepertios havo not at. yet been adequately evaluated.
I'KFA I ME 1ST: Remove patient ! ivm the toxic area. Remove all contaminated clothing and wash all exposed skin thoroughly with soap and water. Flush eyes with copious quantities ol water. Repott to First Aid ii necessary -
SL 008683
of 14 th On aid a 1 District
ho. 91-1145
NAME" Svmmi.lt ital ami Unsvmrnctr ical Tetr at hloroetlmne (Sym, N Dnsym.. TefE'.i
lDhMU.A: t. il( 12^,K 12 and kC^lt^lil M<n.Fi TEAR WEIGHT: lb 1.864
t'.'K.LNC PC-iNL: 292.2i and 2bb,9i' MELTING POINT: -4b,8t and -94,,9F
i'AK'K fRl SSLlKfclM 23.y'C, 4 mm. Hg. and Id mm. Hg iiQlllh DENSITY: M 25(\ 1.588 g/cc and I .,53 3 g/cc
K ! LA T 1 V E VAPOR DENSITY ; 5..'8 (A11 = 1,0l'LAS 11 !','! N !': None
1 ,X 1' i .OS ) VE LIMITS: None
MAX. Al GOWAIfilE C ONI. ,,
5 ppm
SL 008684
DETECTABLE ODOR CONC.; Approximately 5 ppm
HAT ARDOIT PROPER I l E8; The te.trachloroetha.nes are not flammable or explosive,
b-ti are the most toxic of the chlorinated ethanes that will be handled
in the plant
l'hev are toxic by inhalation, prolonged and repeaLed
c ntact, or bv oia! intake. Prolonged or repeated exposures to Tti,f
in n:i;' lornt are hazardous..
Saluu ute |HU!>, mug is the torm usually encoimt 1 red.. Ibis dew hips
gt.ulu.il lv as a res.-It ol prolonged or repeated work in a; 1 a ........... 1 t
containing more thus 5 ppm tot rath 1 oroethaut.
Poisoning can ats. hu.i:
1'V I'etl' being absorbed tlnough the skin.
r.u some L imt , workers with subacute poisoning may show sill 1 such symptoms as iatig.ic, toss ot appetite and abdominal pain. At anv Lime more sevi-tt symptoms such as vomrLing, dizziness, pain over 1 ,u- livti , and jaundice may occur. The symptoms of lel,F. poisoning are d .e t < svstenuc poisoning characterized by damage to the livtr, kidneys, lu.11 1 , blood cells, and nervous system.
TctE may cause dermatitis after repeated or prolonged cent act wuh the skm. The skin becomes rough, red and dry due to the removal of skin oils.. Eye contact can cause serious damage if immediate care is neglected
'The tirst symptoms after toxic a are in itation of stomach, vomiting r It is ah.'.oihod vet v rapidly and even .-a lousuess ,tui! ,1 deep I lushing of tin
lints of TeCE are Laken by manth diarrhea w 1 lIi bloody stools, 'mall amount pi educe tine 011, 1n
le( I-, Will In riu iimUi'i ml in c one oil I 1 .11 ed amount.s in Mu still hoi loins 1 1 * c t > v t11 v sLiearns.
Suh-
iof
-`Jtc, Ta^ r ^eV -
vi s tri
>i der
A-J-145
:>
11-
TREATMENT: Most important in the case of any poisoning is quick removal from exposure. This means first removing the patient from the contaminated atmosphere and removing the TeCE from the skin, or gastro-intestinal tract, if those areas are involved. The patient should he kept quiet and comfortably warm.
A physician should be called immediately and Lold hrielly anti eiearl what has happened.
11 breathing has stopped as a result ot i'eME vapor poisoning,, art i >; rial respiration should l)e started Immediately. Oxygen should b. mini: isteved il an inhalation apparatus ami experienced operaioi are av/i! 'af` If the patient is conscious, ho! tea or coffee may be giver, ,v: a st intd,-
It liquid leOF comes in contact with Lhe .skin the exposed am a m 1 washed thoroughly with water and soan. After this an ointmeni omtaj ;iu lanolin should be applied to replace the natural skin oils. 11 Imli, enters the eyes, they should be washed promptly with copious quantities oi water for at least 15 minutes. Mtdieal attention should he obtained in all cases involving the eyes.
If TeCE is swallowed vomiting should be induced at least three Limes by drinking salty or soapy water. If necessary, the patient should he
encouraged to stick his finger down his tiiroat to induce vomiting. Following this a tah!espoon1u1 ol cpsom salt dissolved in a glass of water slum Id he given.
SL 008685
CONFIDENTIAL: Subject to Protective Order Of 14th Judici:;' Li r.i t Court
Iio, 1-1.:-. Lj
11- I '
I) Electrical Equipment
The character isL its ol EDC are such tliat it is classified in Croup I), Class 1 bv the U. S. National Electrical Code, Ethylene is classified in Giuup C, Class I., The method and materials of installation are those recom mended by Factory Insurance Association, In general, the installation is Class 1, Croup D, Division 2 Motors are TEFC, (Totally Enclosed, JFan Cooled) lighting is vapor-tight, and all arcing devices are explosion-proof with seal offs, Since it is pressurized and isolated from the process area, general purpose equipment is used in the Control Building, The laboratory requires explosion-proof installations, Seal-offs are provided in all conduits leaving the Control Building and entering a hazardous area from a non-hazardous area,,
i. Relamp mg and Receptacles: Vapor-tight fixtures are used m the process area. The rel-amping procedure will be to first determine Lite lamps which need changing by turning on all lights. All lights should then be tinned of) belore re lamping, (.lobes and guards mist be icplaced after relamp ing ,
2, Ground mg; Grounding in the EDC plant has been given special attention due to problems peculiar to the handling oi hydrocarbons and location of the process area.
Grounds for motors and other electrical devices are contained in Lhe conduit supplying the device and connected to the device frame internal ly Motor change-outs should be followed to see that the ground has been connected
Due to Lhe tendency for hydrocarbons to build up a static elec tricity charge as a result of movement, agitation, or free fall through a gas space, a svstem of lumpers for pipe flanges has been installed to provide metallic continuity of the piping system. All vessels are grounded at two points. The results is a system of lines and vessels operating at giound potential. This will nut prevent the generation of static charges, but should provide adequate leakage to ground to prevent the accumulation of dangerous chaiges
The nearness of the radio transmitting station north of the
piocess area presents a problem. Metal objects will act as receivers ol incho
I requeuey energy
It is nut practically possible to prevent this effect
II
is known that the energy picked up will be amplified it the height of Lhe
objocL is a multiple of the transmitter wave length The height ol the still
approaches this condition. The grounding system on the still should eliminate
peisonal hazard and to some degree, act as a shield to equipment south ol the
still-
A particular hazard is created by the use of cranes with long booms. Under certain conditions, depending on the boom length and crane loca tion, it is possible to pick up a voltage high enough to burn the person handling a load that is suspended from the crane. This will occur even it the crane ls grounded, It is also conceivable that an arc would occur if the hooks touch a grounded object,,
SL 008686
ub o a.
COMF1 * t'i p-
M- 1
It is obviously important that t ho grounding s vs loin ho maintained intact. Tliis should ho kept in mind whon periorming maintenance work on any oquipmont in tho KDC aroa.
K. Tools
Special spark-proof or alloy tools aro not required in the hDC area. Ilowovor, precautions should ho utilized when handling tools and oquipmont. Do not strike a metal ohp-or that could cause a spark in the presence ol KDC and air.
1. Pumps and Equipment
Any piece ot equipment that is removed from (ho EIK! process must ne r'.'.crouch 1 v cleaned and inspected before' it ls permitted to leave the area for tr.e shop or Other woik areas
e. Safety Rules fur the FP(; hepm tment
'
ihe iol lowing list oI sale tv rules are applicable to the EDM area, fiic-v are to be used in conjunction with tin.1 limp I oyee fs Salelv Manual
The hbt: area has been designated as Zone lo in the present zone system. 'I lie l)ii eel tonal Center is located inside L iie east door of the Control building. The Kmergencv Code lor this zone is 4-1.
Hu 1 es
1. Personnel entering the EDO area will deposit lighters, matches, regular 1 lash 1ights, etc, , at the gate to this area.
Smokrnt; will be permitted in the control room only, The usual sa fe ty equipment will be required in the EDO area.
a. SafeLy hats b. Sa fe t y g 1 a s s e s C . ia1e l y shoes d llesp i r a t ors e . Neopie iie- c oa t ed gloves
i he est ah l isbed p lant tagg ng procedure wi 1 I apply in I lie EDC
Vompans vehicles onlv will he allowed lo travel the road lo the Centtol build inc, without a permit,
o. A vehicle permit signed bv the operating supervisor will be required for any vehicle to go into the roeess area roadways,
SL 008687
Subject ii'1?Of 14th <a^i-
Uo
,- j . ;. S '.!' -i - v 9i- r43
11- 1 >
An i'(j 111 pint n I j *t i in i t si;;nt d by the ope ra t i ng superv is or will ho ii H iiit.I I'lti'it' the I ' I i iiw : ng t/qiipnunt c an he c.t) ru'd into I lie I- DC .iron
,i , We I ill tip, m.it'll wit's I- (ulli ng r.n i lies c ., I'. I ec i i ic a I J v ilr i vt a drills <1 Any elt tli it.il equipment excepL t x j) Los ion-pi on I I lash l i gilts e. (.as, l me tiiivt .i equipment I Lightens, t i tin s or nnv 11 dine producing equipment g, Hi i mltr r s ,i chipping equipment
8 ,, Only exp 1 os i.m-proof flashlights will be permitted m the ELK, area.,
9. Regular plant itilitv hoses are mu 'fen be used for PIX,.,
l(l All light cirtniLs outside the CoitioL building must he of 1 and tagged be i ore t e t amp i ng
II Do not tfiinp I: Dt into Lvupped sewc-is oi openings wlu-ie haimlul vapors could be tvolved,
12
Vdpi'l'B,
!>o not have open Containers of liDC sitting around to give off
id.. Use Pul 1-)-ace, Chemox ov Scott Air-Pak mask for protection against |- SH vapoi s
1A ,, Never mix chlorine and ethylene in the gaseous phase due to the possibility of a violent reaction.
!5 (lothing that has been wet with EDC should be removed immediatelv and the b idy thoroughly washed with soap and water. These clothes should be prunt-rlv 1 amide i ed In foie they arc used again,
1 e Do not pet mi l ,ur to t ater any oi tlie process equipment tint t .i ins f IK' o\ etliy ! nr ,
1 '' in ease ot un emerge uy waning, all vehicles oi equ i pun nl iliet is in i ho ,ii r,i on pe i in its will he shut '>11 immediately,.
18, All steam-out mv^lts or host- ,uid purge equipment mist be properly g t entitled to pit vent the possibility of ,n ate from an ac c umu la ted static charge
ID Do M t permit ethylene and chlorine to be heated .drove '300^I Decompos11 ion and rrut Lion with metals will occur.
20 No smoking or open flames will be allowed m the control laboratirv
21 The laboratory hood fan is to operate continuously,
22. Always put liquid EIX into tanks through standlegs or through not tom nozzles falling liquid can generate static electricity
SL 006688
C 0N r j p T?7IL>:
Subject to Fro:cii ve Order
Of 14th Judicial r,,.'h^ict Court
No. 9 i -1. i -i 5
11-20
li. clearing ol Tanks and Process Vessels
1 lie area ptoduction supervisor and maintenance supervisor wi I J see . ;e..;t all vessels are cleaned and checked witli an explosion metfcr heioro declaring,
them suitable lor maintenance.
clearing Procedure:
I I I'e tank oi vessel will he emptied ol Its contents and all valves wi11 he closed and tagged.
1. 1 he vapor contents oi the tank will be purged with an inert gas, 3. Blinds will be inserted in a!1 connecting lines.
s. The equipment will he steam purged whe t e possible to vaporize
and remove all 1lammahle materials
\} steam cannot be utilLzed, an inert
gas will he used.
. Purge the equipment, with plentv of air
b. The equipment will then he checked with an explosion meter before work is begun,
/ . Safety belts and saiety lines will be required in top exit tanks.
SL 008689
IV i I'l i I l1 o rin
.1 -
le'L Court
;\ - a ' - x ; 3 =:
iVV/ i . -- vi Jt ^ V
ORGANIC AREA SAFETY PERMIT
43A STD 4-66
To be used to pass restricted equipment into the Organic Area and to be endorsed for the use of such equipment in the
__________________________________________
To: Date:
Location:
Equipment;
Please Check i. Have workmen been provided with
proper safety equipment? 2. Are adjacent areas and equipment
safe? 3. Has adequate fire protection been
provided?
Yes No
4. Is presence of operator required?
Remarks :______________________ _______________________________
Approved:
If a siren or emergency horn sounds, I am to turn off my equipment immediately and" evacuate the area on foot.
Employee's Signature WELDING OR BURNING PERMIT This permit, when signed, allows welding or burning at:
(Location) It is good for: Date____________________ TiTtie---------------------- --......
To- Date---T--i-t-n-e--,-----------------
pM
Special Comments . , ------------------------------------------------------------- -----`----
Signed:
(Area Production Supervisor)
SL 008690
CONFIDENTIAL: Subject to Protective Order of 14th Judicial District Court
No. Sl-li^S
12-1
XII. GENERAL DESCRIPTION OF FIRE PROTECTION FACILITIES IN THE EDC AREA
A, General
This section of the manual presents a general description of the fire protection facilities for the EDC area. This information is to be used for general indoctrination of operating personnel and supervisors, but for specific or detailed information concerning any part of the facilities the manufacturer's instruction booklets and drawings should be consulted. All of these booklets and drawings are available in the equipment files in the area supervisors's office, and all of the control valves have instruction booklets attached to the valves themselves.
The Area "B" Fire Protection Manual contains a complete description of the area fire protection facilities.
It should be remembered that all fire protection facilities in the EDC area are provided with water through an 8" cast iron fire main which con sists of a single loop surrounding the process area. This loop is connected to the main plant's fire main system by a single 8" cast iron line. There are no fire pumps which provide a supply of fire water specifically for the. EDC area alone--the area is totally dependent on the main plant's fire water supply.
The fire protection facilities for the EDC area will be considered in four separate sections: the cooling tower system; the process area system; the transfer tank system including its monitor nozzle station; and the dock storage tank system including its monitor nozzle station.
B. Cooling Tower System
The cooling tower fire protection system is an Automatic Sprinkler Corporation water deluge system which employs their Suprotex Deluge Valve. The system is automatic] The system may be considered to consist of a Con trolling Gate Valve, a Suprotex Deluge Valve, a sprinkler piping network, and a Thermo-Pneumatic fire detection system.
The Controlling Gate Valve for the sprinkler system is the main water supply shut-off-valve, and is an indicator post gate valve located in the underground water supply to the cooling tower's sprinkler system. This valve is located due east of the small red fire house by the cooling towers. The Controlling Gate Valve to this sprinkler system does not have an electric Monitor Switch as described in the Automatic Sprinkler Corporation instruction booklets, and hence, no trouble alarm will be sounded if this valve is closed.
The Suprotex Deluge Valve is a mechanically operated valve which withholds fire water from the sprinkler piping until it is unlatched by the dropping of a weight which is held in place by a diaphragm-operated release mechanism. The Suprotex Deluge Valve has an instruction booklet attached which describes its operation and gives sketches of its parts.
SL 008691
Sub; c 14 t
: ' '
i,' r r1"'
: j', ic:t lOu:;
y i-i b
12-2
The sprinkler piping network is attached to the outlet of the Suprotex Deluge Valve. It conveys the fire extinguishment water into the cooling towers and through open sprinkler heads. (NOTE that these are not fusible heads.) These heads are designed to cover 72 square feet with a density of 0.5 GPM of water per square foot.
The Thermo-Pneumatic system is designed to detect an abnormal rateof-temperature rise, and by mechanical linkage cause a weight to drop and unlatch the clapper of the Suprotex Valve. This system consists of HeatActivated Devices (H.A.D. 5s) which are hollow shells located in the area to be protected and are connected by 1/8" copper tubing to the release diaphragm of the Suprotex Deluge Valve. The Thermo-Pneumatic system is suprovised with air under approximately 24 ounces per square inch pressure. This air is pro vided from the EDC area's instrument air system.
In actual operation an abnormal increase in temperature within the H.A.D.fs will cause an increase in pressure in the Thermo-Pneumatic system which will operate the Suprotex Deluge Valve and, thus, admit water to the sprinkler piping at the tower. There is a pull switch located on the Suprotex Deluge Valve which provides for manual operation of the system if desired.
A water motor gong is installed upstream of the Suprotex Deluge Valve. If the system is placed in operation this gong will automatically sound an alarm. A plug cock is installed in the piping to this water motor gong to provide for testing without placing the system in operation.
A trouble alarm is provided for the supervisory air pressure in Thermo-Pneumatic system. This alarm will sound if there is a loss of super visory air.
CAUTION - If the cover of the release enclosing box on the Surpotex Valve is tampered with, so as to cause air to escape, the Suprotex Deluge Valve will trip and deluge, the protected area with water.
Procedures for resetting and operating the Suprotex Deluge Valve are. given on page 11 of the instruction book attached to the valve.
Two 15-lbs. CO2 bottles provide auxiliary protection in the cooling tower area: These are located just to the east and south of the tower founda tion. Also, a fire hydrant is located just southeast of the cooling towers with necessary hoses and wrenches located inside the red fire house by the cooling tower.
C.. Process Area System
Process area fire protection is provided by an automatic temperature rate-of-rise system that is very similar in operation to the cooling tower system except that it is a foam system rather than a water deluge system. In this type of system a Suprotex Deluge Valve governs, admission of water into the sprinkler piping and another Suprotex Deluge Valve governs admission of
SL 008692
12-3
liquid foam into the piping. Pipe line orifices control the ratio of the two liquids. Once in the piping these two liquids flow to the sprinkler heads where they are aerated as they are sprayed into the area to be protected.
The small concrete brick house just north of the process area contains the water Suprotex Deluge. Valve, two 250 gal. liquid foam supply tanks - one supply and one alternate supply - a separate nitrogen padding system for each liquid foam tank, the liquid foam Suprotex Deluge Valve, the supervisory air system for the Thermo-Pneumatic system associated with the two Suprotex Deluge Valves, the Controlling Gate Valves for the Suprotex Deluge Valves (in this case they are OS and Y gate valves attached directly to the Suprotex Deluge Valve inlet), and the piping associated with the above systems. The foam and water mixture from the house flows under the roadway and into the sprinkler piping in the process area and into the discharge heads that provide a coverage of 0.16 GFM of solution per square foot (approximately 0.65 GPM of foam). Each head covers approximately 80 square feet.
There are two remote control stations which may be used to manually operate the process foam system. They are located in the northeast and south west corners of the process area. They have a breakable glass cover with a small hammer. The system may also be operated manually by the pull handles on the water and liquid foam Suprotex Deluge Valves. If the system is energized by using these two pull handles, the water Suprotex Deluge Valve should be operated first.
Several 15-lbs. C0 and Ansul dry chemical extinguishers provide addi tional protection in the process area. One of these is located near the con crete brick house and the others are located throughout the process area. Two portable foam buggies are also located in the process area, and four fire water hydrants are located around the outskirts of the process area to provide, pro tection if necessary.
The process area protection system has a water motor gong and trouble alarm which operate in a similar manner to the alarms on the cooling tower protection system.
The monitor nozzle located north of the process area can be used to provide additional protection for the process area. This will be explained in the following section.
D. Transfer Tank System
The transfer tank area is protected by a manual foam system. Each individual transfer tank has a foam admission chamber located at the top of the tank. Liquid foam and water are supplied to this chamber through a single inlet pipe, and after entering the foam chamber, they are aerated and admitted into the transfer tank.
The foam system for the transfer tanks uses the same sources of supply for water and liquid foam as the process area protection system. As stated in the previous section, these supplies are located in the small concrete brick house just north of the process area, and consequently, the manual control
SL 008693
Subject CtoFJDE!'mi':
of th Judicia?10rd No. Di-sfcrict Court
12-4
valves for the transfer tank protection system are located in the same build ing. Each transfer tank has a valve for water admission and a valve for liquid foam admission. The four water valves and the four foam valves for the tanks are all located on the west wall of the building. They are color coded similar to the individual tank colors, and in addition, a colored piping diagram is mounted on the piping.
In the event of a fire in one of the transfer tanks the water valve and liquid foam valve for the tank in question should both be turned completely open. NOTE; Always open the water valve first. Line orifices will control the quantity of water and liquid foam admitted to the foam chamber on the tank. The system is designed to provide coverage of 0.63 GEM foam solu tion per square foot (approximately 5 GPM foam).
To secure the system the individual valves in the concrete brick house must be closed. After operation the foam liquid and the water lines should be drained.
A foam monitor nozzle is located just to the west of the concrete brick foam house previously described. This is a manually operated station. Its operation is identical to that of the transfer tanks except that someone must be stationed at the nozzle to direct the stream of foam. NEVER open valves to the monitor nozzle until someone is holding the handles. The control valves for the station are located in the southwest corner of the con crete brick foam house. This station may be used to provide protection in the transfer tank area and in the process area.
It should be noted that" the EDC and MC process areas, the transfer tank system, and the monitor nozzle station all use a common source for liquid foam supply - the two 250-gallon, nitrogen padded tanks in the foam house. One of the tanks is the actual supply tank and the other is an alternate tank. Both tanks have sight glasses to enable operators to determine the amount of liquid foam in the tank. As any of the above systems are operated the main supply tank of foam will empty and the operators will have to manually shift to the alternate supply tank. All operators and supervisors should be familiar with this piping arrangement.
E. Dock Storage System
Fire protection facilities in the dock storage area consist of three separate foam systems. Each dock storage tank has an automatic foam system that is identical in operation to the process area foam system. This means that each dock storage tank has its own liquid foam Suprotex Deluge Valve and water Suprotex Deluge Valve. They both have a common liquid foam supply which is a nitrogen padded 300-gallon tank. There is no alternate supply tank. Supervisory air for the two Thermo-Pneumatic systems is provided from the plant instrument air system. All four Suprotex Deluge Valve, Controlling Gate Valves, supervisory air systems, the liquid foam supply, and associated piping are located in the small concrete brick foam house just west of the diked area.
SL 008694
12-5
The foam admission chamber on the top of each dock storage tank is slightly different from the chambers on the tops of the transfer tanks. The chambers on the dock storage tanks contain a long rolled tube which rolls down to the EDC liquid level in the tank whenever pressure is applied to the inlet to the foam chamber. After use this tube must be re-rolled manually. The tube serves to convey the foam down to the EDC level without splashing the EDC itself.
The third system at the dock is a monitor nozzle station that is identical in operation to the monitor nozzle station north of the process area. The station at the dock storage area is located due west of the diked area, and its manual control valves are located in the. concrete brick foam house. The nozzle uses the same foam supply tank as the storage tank automatic systems.
The manual Gate Valves in front of the water Suprotex Deluge Valves are maintained in the closed position. This is done to prevent the accidentia! tripping Of the foam system and thereby ruining valuable product. In the event of a fire, the H,A.D. in the tank will respond and trip the water Supro tex Deluge Valve, which in turn sets off an alarm at the plant guard station The guard in turn notifies the EDC operator and the EDC operator immediately checks into the situation at the Dock Storage. If the fire is only at the vent valve outside the tank, the operator extinguish it with the monitor nozzle. If the fire is inside the tank and on the liquid surface, then the operator should manually open the Gate Valve in front of the Suprotex Deluge Valve which in turn will foam the entire liquid surface within the tank.
SL 008695
CONFIDENT!; LSubject to Protective Order cf 14th Judicial District: Court
Xi J 1 , Properties of Compounds
Some physical and thermodynamic properties that may be useful in LDC plant operations are included in this section. The. properties included are. listed below:
Compound
Proper tv
Figure
Page
r; 111V 1 e n e Dichlor Lde
Vapor pressure
13. 1
13-2
11 t hv I one D i ch lor ill 3 11 Liiy 11 no 0 i ch 1 or[d e
IV nr S tv V i '-.(MC 1 1 V1
J J.. M.ll
13-3 1V
fit by 1 i'ih' Dichloride
Latent heat
IJ.n
13- '
11 thy lone Pi.eh Lor ide
Sptrciiii Heat
13,5
13-6
SL 008696
869800 IS
NO. :^Of?-2D DIETZGEN GRAPH PAPER 20 X 20 PER INCH
EUGENE DIETZGEN CO. MADE IN U S A.
; -,'V isco sity, C e n tip b ise s
NO J4UK-2Q Lil i i.3EN 7.n v 20 PER INCH
PA.
El________ : DIE______ I CO.
MADE IN U. S. A
L a te n t-H e a tV a p o risa tio n
:
. BTU/LB;' i ;
ND 34DR-2Q Dl ETZGEN GRAPH PAPER 2D X 20 PER fNCH
EUGENE D1ETZBEN CO MADE i N U S. A.
20 BfWfGEN'
H P,
20 X 2D PER INCH
Z^>
XIV.
OPERATIONAL GRAPHS
r....
i
to " '
`
ydD'j>-t ;. : ; njctric* '-
of; Lath Ju^"A;i_u45
14-1
Tliis section contains graphs that will be useful in plant' operations The graphs included are listed below:
Graph Feed Gas Rates vs. Production Stripper Steam Fiow vs. Reflux Still Reflux Flow vs. Feed FeClj Required for Catalyst Additions Catalyst Master Mix Preparation
Figure 14.1 J4.2 14.3 14.4 14..H
Page 14-2 14-3 14-4 14- S 14-6
SL 008702
- , ' "`NO D R - 2 " T Z Q r ' A P H --------- R
2Cj a
F l R riN un
' 'L L : D i r ^ ' ` ^N CD
14-;
1-4-3
2 0 PER IN C H
1
u Z<
ai
d
I<
aX uI
z
N
y
2