Document rBv843OLYzmLjk7n4egOgmjvv

ENTRAL ... ... flliJEtlsiG 1 N^EiE;'R||^G. gg **#*' E P A R T ME N T CEA NO. 1430 PRODUCT PROGRESS REPORT AR NO. DATE Feb. 23, 1968 Aroclors title ' ! Increase Aroclor Capacity DISTRIBUTION CEO SECTION MANAGER ced project manager R. P. SteVeHS R. W. Peterson DIVISION Organic PLANT Anniston division representative_______W. F. Taffee O. R. Bailey J. M. Depp M. Dmytryszyn R. E. Emling F. W. Enoch F. J. Holzapfel R. W. Kaltenrieder F. P. LaBelle R. E. Lenz Russell L. Miller E. Negro C- L. Parish A. B. Terry (2) ORGANIC DIVISION H. C. Carder R. J. Stratmeyer A. L. Klemm H. L. Williams (Lett- W. J. Burkett . R. R. Cook/R. ,'c. Herman R. E. Howard SCOPE Aroclor production facilities at Anniston will be expanded by the addition of tankage for storage and for the preparation of blends, drumming facilities in a new building (to be expanded on another project, CEA 1452, into a product warehouse), new and larger flakers for solid Aroclors and for.biphenyl in the same building, and packaging equipment for flaked products. Tank truck loading and a new track spur with tank car loading and unloading facil ities are included. DSW 200658 CONFIDENT I AL in for m at i o n THIS DOCUMENT IS THE PROPERTY OF MONSANTO COMPANY AND THE RECIPIENT IS RESPONSIBLE FOR ITS SAFEKEEPING AND DIS POSITION IT CONTAINS CONFIDENTIAL INFORMATION WHICH MUST NOT BE REPRODUCED. REVEALED TO UNAUTHORIZED PERSONS OR SENT OUTSIDE THE COMPANY WITHOUT PROPER AUTHORIZATION. CE- 14 STLCOPCB4058722 > ProductAroclors i_ocat j on Anniston Title Increase Aroclor Capacity______________________________________________ Data Tabulated As Of February 9, 1968 CEAWo. 1430 ARtfa Appropriation Current Estimate Date of Estimate Expended A Committed Spent This Month Scheduled Completion On Schedule? MS 1,400 MS 1,307* December 1967 MS 336 MS 29 August and October No (Sewer Delays) 1968 Process Design, % Complete Mechanical Design, % Complete Construction, % Complete 1 % Expended & Committed Design Manpower | Construction Manpower 1430 Last Month This Mo. 74 80 50 60 19 26 1 2 12 -- AT 8 * $93,000 being handled under CEA 1452 SUMMARY; Corrective sewer work is underway. Tank farm start-up will be August instead of July, and flaker-packaging probably mid-October. Detail definition of the flaker area is now underway. Field Work; The 24" process sewer is now being relocated. Gunnite repairs to the 36" storm sewer are well along, and promise to be successful. A new sanitary sewer has been tied in permitting excavation of septic tank fields. Power poles have been relocated to clear the site. We now plan setting tanks 5/6/68. About seven weeks were lost; two may be regained before start-up. Tank Farm: Design is well along. Plant ammendments to the blending process will require modifications at blend tank auxiliaries. A few in strument details remain to be resolved,, Flaker-Packaging: A workable layout has been developed on the study model and is be ing discussed with the plant. The flaker vendor's strike has not been settled. Quotations have been requested on solids handling equipment. Tests are planned at selected vendors. ' R. W. Peterson Acting Project Manager vo OS***1669 STLCOPCB4058723