Document rBg7bx4m1qDx8xmRxwra5oo30
Heating Systems B0a Ptedm
McDonnell & Miller, Inc.
Safety Devices for Steam and Hot Water Heating Boilers and Hot Water Tanks 3500 N. Spaulding Ave., Chicago 18) Illinois
The McDonnell line consists of the following safety devices: (1) For Low Pressure Steam Boilers . . . Boiler water feeders, low water fuel cut-offs and combined feeders and cut-offs; (2) For Higher Pressure Steam Boilers . . . Pump controls, low water fuel cut-offs and low water alarms for pressures to 150 lbs, and receiver make-up water, feeders; (3) For Hot Water Space Heat
ing Boilers . . . ASME pressure relief valves, boiler water feeders, low water fuel cut-offs and combined feeders and cut-offs; (4) For Domestic Hot Water Tanks and Heaters . . . ASME pressure relief valves, temperature relief valves and combination T & P relief valves. McDonnell also manufactures liquid level controls for humidifying pans and many other applications.
1 LOW PRESSURE STEAM BOILERS
Service Recommendations
Boiler Size.
Maximum Steam Pressure
______McDonnell Product to Use
For Automatically! Fired Jobs |
For Hand Fired Jobs
Boiler Water Feeders and Feeder Cut-Off Cdmblnations
Up to 5000 sq ft Aoove 5000 sq ft Any size
25 lbs 35 lbs 75 lbs
No. 47-2 No. 51-2 No. 53-2
Low Water Fuel Cut-Offs (/or Automatically Fired Jobs)
Any size Any size
20 lbs 50 lbs
No. 67 No. 63
No. 47 No. 51 No. 53
McDONNELL Boiler Water Feeders and Feeder Cut-off Combinations
McDonneU No. 17-S
McDonncU No. 51-S
McDonnell No. 53-t
McDonnell No. 47-2 Feeds water when necessary to maintain safe water level in boiler. If water level for any reason
falls into emergency zone, cut-off switch cuts burner circuit until emergency has passed. Has "Quick-Hook-Up" for in stallation in gage glass tappings; "cool" feed valve; extra-deep sediment chamber; stainless steel valve and seat; ASME approved blow-off valve. Also
available for hand fired jobs without No. 2 Switch, as No. 47 Feeder.
McDonnell No. 51-2 is same as No. 47-2, except it has greater feeding capacity for larger boilers, and is installed with 1 in. equalizing pipes instead of "Quick' Hook-Up." Also available for hand fired boilers without No. 2 Switch, as No. 51 Feeder.
For boilers operating at higher pres* sures, from 35 to 75 lbs, use McDonnell No. 53-2 (or No. 53, without switch)-
1490
Heating Systems ISSTSgS
McDonnell Low Water Cut-offs For automatically fired steam boilers of any size
Marimnm steam pressure, 20 lbs. No. 67 has McDonnell "Quick-Hook-Up" for installation in gage glass tappings; deep sediment chamber with large open ing blow-off valve; packless non-binding construction; adjust able terminal box; snap-action twin switches. One switch can sound low water alarm, or control McDonnell No. 101 Electric Water Feeder; second switch cuts burner current if water level drops into emergency zone. No. 61 has same mechanism as No. 67 but has larger body for installation with 1 in. equalizing pipes. 69 Series "Built-ins" meet same operating conditions, fit 23^ in. tappings provided by many boiler manufacturers. Order by boiler make, model.
McDonnell No. 101 Electric Boiler Water Feeder For boilers up to 5000 sq ft capacity.
For use with No. 67 Low Water Cut-off, No. 61 or "Built-ins" which are standard equipment on many modern heating boilers. Its use converts cut-off into feeder cut-off combina tion.
2 HIGHER PRESSURE STEAM BOILERS
McDonneU Pump Control, Low Water Fuel Cut-off and Alarm Switch for steam boilers of any size; maximum steam pressure, 150 lbs.
The McDonnell No. 150 Pump Control, Cut-off and Alarm switch for high pres
sure and temperature. Has two switches; one controls electric feed pump or elec tric valve in line to steam pump; second stops burner on greater float drop and completes alarm circuit. Underwriters' Laboratories approved. No. 150 has automatic reset; for manual reset order No. 150-M.
No. 157 is same as No. 150, but has integral water column which simplifies installation, assures ideal reproduction of boiler water level in float chamber, and provides effective direct blow down. Available with varying water column sizes and tappings to suit practicaUy aU conditions. No. 157 has automatic reset; for manual reset order No. 157-M. (Tri-cocks and gage glass not included.)
Operation of No. 150 or No. 157
Typical hook-up of the McDonnell No. 150 is shown at right. When water level drops, No. 150 starts pump and stops it when normal level is restored. In emer gency, cut-off switch stops burner; ter minals for low water alarm are also
provided. This method holds boiler water level
within the close limits necessary to at
tain maximum steaming efficiency. Note McDonnell No. 27 make-up feeder on receiving tank. Drawings are avail
able for all operating conditions, includ ing two or more boilers supplied by ne pump.
1491