Document rBaJ9xaGm7XoQVBgKDqxba0K0

JOB HAZARD ANALYS8 DIVISION Borden Chemical DEPARTMENT PVC__________ SEQUENCE OF BASIC JOB STEPS 5. Install Ladder 6. Enter Reactor SECTION LOCATION or BRANCH Leominster JOB TITLE Reactor Cleaning POTENTIAL ACCIDENTS OR HAZARDS RECOMMENDED SAFE JOB PROCEDURE 1. Improperly installed ladder could fall and result in a fatality. 1. Check ladder to be sure it has no broken or cracked rungs or wet or slippery rungs. 2. Be sure it has rubber feet 3. Install ladder by putting it in feet first. 4. Ladder feet must straddle one blade. 5. Be sure feet rest securely on the bottom and do not set over the bottom outlet. 6. Test ladder to be sure it is stable by trying to move it sideways and back and forth 1. Fall from ladder. 2. Overcome by vapors, etc. 3. Cut from scraper not in pouch. 4. Drop tools or fall on man below. 1. Be sure reactor has been aired out for 20 minutes. 2. Be sure all tools are in the pouch. No pointed ends are to be exposed. 3. Install "Man In Reactor" sign. 4. Be sure someone is present 5. Climb the top of the reactor dome. 6. Facing the front of the reactor, carefully step onto the top rungs of the ladder. 7. Hold on to the manhole anc be sure the ladder is stable. 8. Decend the ladder one step at a time. 9. If at any time, vapors are observed, immediately leave tl reactor. 10. Go immediately to the bottom of the reactor, check for vapors. Your sense of smell can be deadened if you don't do this first. PREPARED BY: Russell L. Mercier REVIEWED BY: John Isler> Jr* .DATE: July 30, 1971 nayp August 3, 1971 BOR 000205 JOB HAZARD ANALYSIS DIVISION Borden Chemical DEPARTMENT PVC SECTION LOCATION or BRANCH Leominster JOB TITLE Reactor Cleaning SEQUENCE OF BASIC JOB STEPS POTENTIAL ACCIDENTS OR HAZARDS RECOMMENDED SAFE JOB PROCEDURE 11. Ch eck that bottom outlet valve is open. 12. Check that plugs and valves are all closed on manifold valves. 13. Check that manual vent is open. 7. Clean Reactor 1. Chips in eyes. 2. Cuts from scraper. 3. Vapors causing death. 4. Fells from ladder. 5. A.0.L. 6. Improper cleaning of thermowell, bottom outlet or recovery header or manual vent could lead to an explosion, death or plant disaster. 7. Improper cleaning of dome and walls will also lead to quality problems due to fisheyes and poor heat transfer and increased particle size. 1. Always wear PVC coated gloves to reduce possibility of A.O.L. 2. Always wear eye protection 3. Whenever vapors are presen sound the alarm on alarm cart. 4. Always scrape away from yo Scrapers are razor sharp and can cut severely. 5. Never over reach when on a ladder. Always get down and move the ladder, being sure it is always stable and straddl the blade. 6. Only one man on a ladder at a time. 7. Never stand under the ladder when another man is on it. 8. Reactor bottoms are round and slippery. Always use extreme caution. 9. Be sure all lines are cleaned - manual vent, relief valve, charge nozzles, etc. LO. Pick up all.tools and polymer before leaving the reactor. LI. Exit from the reactor in reverse order of entering. .8 Remove all Safety Equipment -- ' IU- ... 1. Loss of equipment and possible charge of reactor Iwith flashlight or other 1. Be sure to remove all cord from the reactor. --2-.---R-e-m-o-v-e--la-d-d-e-r-.i PREPARED BY - Russell L, Mercier .DATE: July 30, 1971___________ REVIEWED BY: John Ssler, Jr- DATE: Auflu8t 1a. W2X BOR 000206 JOB HAZARD ANALYSIS DIVISION Borden Chemical__________ ______________________ DEPARTMENT SECTION PVC I LOCATION or BRANCH , Leominster JOB TITLE Reactor Cleaning SEQUENCE OF BASIC JOB STEPS POTENTIAL ACCIDENTS OR HAZARDS object inside causing contamination of product. RECOMMENDED SAFE JOB PROCEDURE 3. Reinstall rope fall t normal position. 4. Remove sign. 9. Unlock Reactor Agitator 1. Loss of agitation. 2. Deactivation or activa tion of wrong agitator could cause an accident to someone else. 1. Double check reactor number. 2. Go to MCC room and remove lock from switch. 3. Return to reactor room and remove pin from stop button. 4. Check agitator to be sure it goes on. 5. Notify operator. PREPARED BY. Russell L. Mercier REVIEWED BY: Fwm L-82S('M-M) John Isler, Jr. BOR 000207 DATE: July 30. 1971 August 3, 1971 ,DATG