Document rBQJGKzyqdb3navNOxjNwJo60

Air Conditioning Hayes Furnace Mfg. & Supply Co. 2929 South Fairfax Ave., Los Angeles 16, Calif. (TelephonyTexas 0-3734) Contact Nearest Representative. Associated Refrigeration Kngrs., Montgomery, Ala. M. Blazer & Son, Passaic, N. J. Blue Flame Supply Co.. Atlanta, Ga. Eugene Bobtad, Edmonton, Alberta,*Canada E. B. Bomar, phoenix, Arizona i Boyd Engineering Co., Albuquerque, New Mex., and El Paso. Texas Dealers Supply Co., Atlanta, Ga. Reube O. Emery, Nashville, Tenn. Jewell & Co., Hot Springs, Ark. Leudecke Engineering Co., Austin, Texas Homer Maxey & Co., Lubbock, Texas McCombs Supply Co., Denver, Colo. Noland & Co., Newport News, Va. O'Connor-Oklahoma Co., Oklahoma City, Tulsa, Okla., and Wichita, Kansas Smith Steam Specialty Co., Kansas City, Mo. Tay-Holbroob, Inc., San Francisco, Calif. F. R. Young, Houston, Texas DUCT FURNACES Constructed of Type 321 Stabilized Stainless Steel. Non-cor rosive property of heat exchanger permits installation down stream of cooling coils or washer. Heat exchanger will not corrode when subjected to continuous ventilation during the summer season. Designed for continuous blower operation for offices, theaters, schools, churches, factories. Air throughput in either direction. Draft Hood and Vent Manifold reversible, adjustable for both horizontal and vertical connection. 14 sizes, 80,000 to 600,000 Btu per hr input in 40,000 Btu incre ments. A.G.A. certified for all gases. MODEL SED-E Non-corrosives type 321 stainless steel heat exchanger. Per mits installation downstream of cooling equipment, for con tinuous blower operation. Air throughput in either direction. 80,000 to 600,000 Btu input. MODEL SED-S Same as SED-E except controls are at the side, instead of at the end where accessibility requires. SED-S is available in sizes from 80,000 to 600,000 Btu input in increments of 40,000 Btu. Both SED-E and SED-S can be UBed for industrial applica tions for drying. FORCED AIR FURNACE MODEL SEC Heat exchanger constructed of identical die formed sections of type 321 stabilized stainless steel. Sections are seam and arc welded. One piece cast iron burners with drilled portsOversize double inlet blower. Long hour motor. Equipped with glass filters. Can furnish permanent filters at extra cost. Finished in baked silver grey. 6 sizes 70,000 to 245,000 Btu per hr input in 35,000 Btu increments. For natural, manufactured and L.P. gases. Can be used for 0 clearance ALL HAYES FURNACES ARE A.G.A. APPROVED 1234 Hayes Furnace Mfg. & Supply Co. Air Conditioning Automatic Equipment Gas Fired Units DUCT FURNACE MODEL SED-VF Tested and approved as a DUCT FUR NACE--Constructed of type 321 sta bilized stainless steel. Re-circulated or fresh air is introduced through bottom, sides or back of furnace. Equipped with air bypass. Handles large cfm per Btu input. Vent in front of furnace. Made in 6 sizes from 70,000 to 245,000 Btu per hr input in increments of 35,000 Btu. For natural, manufactured and L.P. gases. FORCED AIR SUSPENDED FURNACE, MODEL SES Equipped to install in a suspended duct system. Inlet and outlet designed for sheet metal duct connection. UNIT HEATED MODEL SEU Used where room air is to be recircu lated. Diffuser outlet with adjustable vertical and horizontal vanes. Both types of Suspended units are designed for factories, commercial and other large Btu requirements -- equipped with brackets for suspension, save floor space. Double inlet forward curve blower. Continuous duty variable pitch drives; cast iron, raised port, precision ma chined burners. Made in sizes 80,000 to 600,000 Btu per hr input in 40,000 Btu. increments. For natural, manufactured and L.P. Gas. EJECTAIR Power Roof Ventilator by HAYES Centrifugal backwardly curved blower type . . . the blower wheel cannot be overloaded regardless of length or curves [Q the duct or variation in design. It is Pelt driven to provide flexibility. The ventilator is mounted on a built up 'FJ on the roof. Special features in clude low profile with streainlined deIJgn and a corrosion resistant housing. 1 i 'n,for an<i tan bearings are grease packed ball bearings and are out of the ir stream. A manually operated safety cutoff switch is provided _____ ___________ DIMENSIO NS B 15V* 17 V* 24 M 2545 27 v* 30 3044 3214 3444 36 M 40 42 V* 41H 49 54 5714 c nv* 13 13V* 16V* 20 20 22 V* 25 28 31 33V* 40V* 40 44 V* 50 55 D 19V* 21 21 24V* 28 28 30V* 33 36 39 41 48V* 52 56 62 67 APPROX. SHIP. E WT. 16 130 16 137 16 180 16 275 16 300 16 325 16 350 16 500 16 590 16 630 16 700 16 795 16 875 16 1120 16 1500 16 1900 1235