Document rBKbYx5zNDNvGL9Gna1nR05oJ

/ ^WGIW.ANALYTICAL RESEARCH AND DEVELOPMENT REPORT^ OTHER LOCATIONS GENERAL OFFICE 2l6l, June l6 1Q72 W. G. KRUMMRICH PLANT E, E. Stewart A. E. Leisy W. C. Engman G. A. Hiope File ` TITLE; COMPANY CONFIDEMTIAL PCB Reduction in Tank Car Wash Water - Dept. 2^6 PERSONNEL: PROBLEM: J. A. Gloeckner, X. L. Schutzenhofer (H. J. Horner) Decanted aroclor tank car wash water contains PCB's in the ppm range, whereas solubility is believed to be about 300 ppb. A procedure must be devised to remove more PCB's from the wash water before sewering. JUSTIFICATION: ' Permit eventual control of PCB content in the sewer stream from the plant to 0.5 ft/day. SUMMARY: Based on laboratory tests performed to date, it appears that the most effective procedure for removal of PCB's from the wash water is filtration with either lime or carbon. dy N6K <7? H. . . CONFIDENTIAL This report is fhe property of Monsanfo Company- and the rec ipient is responsible for its safekeeping and disposition. If contains confidential information of Monsanto Company which mast not be reproduced, revealed to unauthorised persons or sent outside the company without proper authorisation This report is to be retained in a secure file or destroyed. DSW 345180 t f STLCOPCB4083962 AR&D Report No. 2l6l Page 3 June 16, 1972 Discussion of Results The sample used for Tests #1 - #10 was thoroughly mixed before obtaining portions for each test. The sample solution was allowed to settle for two hours, after treatment, before decanting in the tests as indicated. The filter paper used in each test as indicated was 1-3 micron, glass fiber paper. The sample used for test #11 was a turbid, light green-brown liquid with brown residue on the bottom and also floating, on top. A portion of this sample was taken for analysis from the middle of the sample in an effort to exclude the residue. Conclusions A comparison of the as is analyses of the sample taken from the catch tank and the sample taken directly from the tank car is not a good one because the catch tank sample was thoroughly mixed and the tank car sample was allowed to settle before analyzing. It appears that the PCB content is directly proportional to the amount of solids present in the sample portions used for analysis. The only decanting procedure that shows any promise Is that made after lime treatment. Comparable results could probably have been achieved with carbon, also. Decanting procedures will require some settling time. Reference WGK Research Notebook, pp. 16026-16029, 16032-16033. qSNN 'T STLCOPCB4083963 AR&D Report No. 2l6l V Page 2 June 16, 1972 Details Background Facilities were installed at the Rip Track to permit the continuous decanting of wash water as part of the aroclor tank car washing procedure. It was hoped that after settling, the decanted wash water would oontain polychlorinated biphenyls at approximately the 300 ppb level. However, the sewered water has been found to contain PCB's in the ppm range. The tank cars are wastr'with H2O only. This water is collected in a catch tank that may contain residual detergent solutions from washes of other types of tank cars. The aroclor car washes are passed from this catch tank to a 6000 gallon settling tank. After a settling period the wash water is decanted from the top of the trailer. It Is thought that an emulsion might be forming in the wash water, accounting for amounts above the 300 ppb level In the decanted water. Procedure . A one gallon sample of aroclor wash water was taken from the catch tank. This material was tested for demulsifying and filtration. Results This sample was a turbid, yellow liquid with some residue on the bottom. The pH of the sample was 7.6. Test No. PCB's ' ' (ppm) 1 51*.48 2 0.726 3 1.58 4 0.007 r\ 5 0.074 6 22.93 7 0.466 8 18.23 9 3.24 10 8.25 11 2.82 Type of Test Sample as Is (after mixing). Mixed with filter aid and filtered thru filter paper. Filtered thru filter paper, only. Carbon treated and filtered thru filter paper. NaCl treated and filtered thru filter paper. NaCl treated and decanted. DSW345182 CaO treated and decanted. Acetone treated and decanted. Filtered thru polypropylene bag filter, only (5"micron). AICI3 treated and decanted. New wash water sample taken directly from a tank car. This sample was allowed to settle and then decanted for analysis. TT' STLCOPCB4083964 Monsanto FROM (NAME A LOCATION t K L Schutzenhofer WGK March 25, 1974 PCB Analysis of Water Scrubber Samples ' TO K. . Boucher COMPANY CONFIDENTIAL cc L. H. Horcher C. F. Buckley G. A. Hlppe H. J. Horner The following results were obtained on the analysis of the samples, as listed, for PCB content. Bottle 1 4 6 7 9 10 11 14 16 17 19 No Sample ' 3/20/74, 12.25 pm i 9 12.45 pm f I f 9 1.05 pm, 9 1.25 pm, 9 1.45 pm, 9 1.45 pm, > 2.05 pm, t ' 9 2.25 pm, 1 I 9 2.45 pm, 9 3.05 pm, 9 3.25 pm. 0 min. 20 min. 40 min. 60 min. 80 min. 80 min. 100 min. 120 min. 140 min. 160 min. 180 min. PCB*s (ppm) 44.6 8.92 3.73 2.75 3.11 20.2 3.87 2.96 1.73 3.05 1.61 The above results were obtained by WGK Method No. S-005, utilizing the Cary Spectrophotometer, and do not include 1109 aroclor content. Reference. WGK Laboratory Notebook, pp.17871-72. dy IN - 10 REV. 1 72. DSW 345183 STLCOPCB4083965 Monsanto K. L. Schutzenhofer FROM l NAME A LOCATION! March 19, 1974 PCB Analysis of Water Scrubber Samples TO K. E. Boucher COMPANY CONFIDENTIAL C. F. Buckley G. A. Hlppe H. J. Horner The following results were obtained on the analysis of the samples, as listed, for PCB content. Bottle No. Sample Time PCB1s (ppm) 1 3/12/74, 12.30 p.m. 0 min. 1.77 3 3/12/74, 12.45 p.m.,15 min. 0.85 6 3/12/74, 1.00 p.m.,30 min. 0.40 8 3/12/74, 1.15 p.m.,45 min. 1.06 9 3/12/74, 1.30 p.m,60 min. 0.69 11 3/12/74, 1.45 p.m.,75^min. 1.21 13 3/12/74, 2.00 p.m.,90 min. 0.61 15 3/12/74, 2.15 p.m.,105 min. ' 0.67 18 3/12/74, 2.30 p.m.,120 min. 0.55 Ref. WGK Labotatory Hotebook pp.17868-69. dy IN - 10 REV. 1 72 DSW 345184 STLCOPCB4083966 Monsanto 4 * niw( A LOCATION! K. L. Schutzenhofer K ---- ----- ' 1 - "| I j ! _____ February 25, 197*1 PCB Analysis of Scrubber Water Samples t ii f TO : : K. E. Boucher COMPANY CONFIDENTIAL . 1 - .... 1 cc C. F. Buckley G. A. Hippe H. J. Horner The following results were obtained on the analysis of the samples, as listed, for PCB content. Sample Identification PCB's (ppm) 1. 2/11/7*1, 12:10 p.m. Continuous Chlorinator-75?, no batch chlorinators - 2. 2/11/7*1, 3:*<5 p.m. Continuous chlorinator - 65%, one batch chlorinator 3. 2/12/7*1, *1:15 a.m. Continuous chlorinator -75%, two batch chlorinators *1. 2/12/7*1, 8:00 a.m. Continuous chlorinator - 70?, no batch chlorinators 5* 2/13/711, 8:00 a.m. Continuous chlorinator - 75?, no batch chlorinators 6. 2/l*l/7*l, 9:00 a.m. Continuous chlorinator - 75%, one batch chlorinator 7. 2/lV7*l, *1:30 p.m. Biphenyl feed - unknown, no batch chlorinators 8. 2/15/7*1, 7: *15 a.m. Biphenyl feed- unknown, batch chlorinators unknown 9. 2/15/7*1, *1:30 p.m. Biphenyl feed -75%, no batch chlorinators 1.62 12.7 *1.00 0.67 0.87 0.67 0.68 0.65 1.35 Reference: WGK Lab Notebook pp 17853-5*1. dy * * J - 1C BEV. . ~ 2 DSW 345185 STLCOPCB4083967 Monsanto *.OM -NiMt & LOCATION DATE suavrcr CliCNCi TO K. L. Schutzenhofer - WGK April 4, 1974 PCB Analysis of water Scrubber Samples K. E. Boucher COMPANY CONFIDENTIAL cc C. F. Buckley G. A. Hippe H. J. Horner The following results were obtained on the analysis of the samples, as listed, for PCB content. The results were obtained by WGK Method S-Q05, utilizing the Cary Spectrophotometer. Set No . 4 (3/29/74 samples) Bottle 0 2 4 6 7 10 12 14 16 17 No. Sample Time before start-up 1.00 pm, 0 min. 1.15 pm, 15 min. 1.30 pm, 30 min. 1.45 pm, 45 min. 2.00 pm,60 min. 2.15 pm, 75 min 2.30 pm, 90 min. 2.45 pm, 105 min. 3.00 pm, 120 min. PCB's (ppm) 1.31 12.2 5.88 3.45 5.13 3.68 3.16 1.68 1.40 0.84 - Set No. 5 (4/2/74 samples) Bottle 1 3 5 7 9 11 13 15 18 No. . Sample Time 11.00 am, 0 min. 11.15 am, 15 min. 11.30 am, 30 min 11.45 am, 45 min. 12.00 noon, 60 min. 12.15 pm, 75 min. 12.30 pm, 90 min. 12.45 pm, 105 min. 1.00 pm, 120 min. PCB's (ppm) 2.47 2.42 2.37 2.19 1.96 1.66 1.48 1.47 1.56 Reference. WGK Laboratory Notebook, pp.17879-82 dy IN - 10 P E V. 1 72 STLCOPCB4083968 $GK ANALYTICAL RESEARCH AND DEVELOPMENT REPORT No. 2450, 4/24/74 OTHER LOCATIONS GENERAL OFFICE J. R. Savage - B2SL - COMPANY CONFIDENTIAL W. G. KRUMMRICH PLANT K. E. W. C. G. A. A. E. E. E. D. K. R. M. J. R. File Boucher Engroan Hippe Leisy Stewart Lynch McCutchan Kuster TITLE: ,, ' Dept. 246 - Aroclors. Start-up of HC1 Off-Gas Scrubber PERSONNEL: F-MOSLEM: K. L. Schutzenhofer, L. H. Horcher (H. J. Horner) The off-gas efficiency, of analysis start-up of JUSTIFICATION: must be analyzed for PCB's to and the life of the scrubbing must be developed and samples this equipment. nr determine the material. Methods analyzed to facilitate For environmental reasons, the PCB losses to our sewers must be drastically reduced or eliminated. SUMMARY: A fifteen tray Aroclor scrubber was started up at the end of February using MCS 1016 bottoms to remove Biphenyl and PCB!s from the off-gas Before sewering or going to chlorosulfonic acid production. We developed a procedure and analyzed the scrubber liquor daily. The gas itself was not analyzed but the water used to drown the I1C1 gas was analyzed using both a routine GC procedure and a new ultra-violet method recently developed for another product. References. WGK Notebook 17853-54, 17868-69, 17871-73, 17879-82, 17884-85, 18201-17, 18221, 18231-32. dy L. H. Horcher CONFIDENTIAL Daw 345187 WOK ITT *M . f . This report it tha proparty of Momonto Company and the recipient it ratpontiblt for itt tofakaapinq and ditpotition. It contain* confidential information of Monsanto Company which mutt not be raproducad, revealed to unoothorited partont or tant outtida tha company without proper author iiaiior,. Tfiie report it to ba retained in o tacura file or da ttroyad. r STLCOPCB4083969 AR-D Report No. 2450 Page 2 April 24, 1974 Details Background . The scrubber is based on work done by N. Thompson in the summer of 1972 to reduce the loss of PCB's in HC1 off-gas to less than 2.5 lbs/day. A fifteen tray scrubber was designed on this basis using MCS 1016 bottoms as the scrubbing liquor. In order to start-up this equipment, a procedure to determine the mono- and lower dichlorobiphenyl build up in this liquor is required. The amount of PCB's in the gas after scrubbing also needs to be known. Method Development Scrubber Liquor A procedure used to determine the higher boiling homologs in MCS 1016 was modified to analyze both the low boilers in MCS 1016 Bottoms, the Biphenyl, and PCB's scrubbed out of the gas by the liquor. The initial procedure using normal C^g as the internal standard required about ninety minutes per analysis. After the installation of a backflush valve, since we are interested in the low boilers, the analytical turnaround time was reduced to 45 minutes. An additional bonus is that reversal of gas flows should increase the life of a rather expensive column. The procedure' is published as WGK Method No. T-2320 and is in routine use by the analytical section. Data is attached in Appendix A. HC1 Drowning Water An ultra-violet method (Method No. S-0055) developed for total PCB content in cooling water was used to analyze a series of water samples taken during the drowning of the HC1 off-gas. This was to determine the efficiency of the scrubber (PCB losses to sewer in the gas). Data has been published in memos dated Feb. 25, ftar. 19, 25 and April 4, 1974 to K. E. Boucher from K. L. Schutzenhofer. We also used Method No. A-1009 to determine the type and amount of PCB's. Data is attached in Appendix B. The above work allowed us to determine the mono-chlorinated and poly chlorinated biphenyls but it gave us no information of the amount of biphenyl going to the sewer. A further concentration procedure of the extracts made for the other analyses was done and analyzed on a FID instrument. Our biphenyl levels ranged from 5 to 50 ppb but our total MCS 1109 from the FID analysis was lower than that by EC analysis. It is possible that 'the EC values are high due to resolution problems or the FID values are low due to losses occurring in the vigorous concentration techniques used. DSW 345188 STLCOPCB4083970 AR-D Report No. 2450 Page 3 April 24 1974 Conclusions We were able to successfully monitor the start-up parameters without any undue delays. Procedures in standard form were published and the analytical personnel have been trained to use them on a routine basis. The scrubber liquor life is greater than the expected 7 to 10 days and the average losses to the sewer are at the level targeted by design. We, however, found the.rate of build-up of biphenyl and mono-chlorobiphenyls was erratic and a better measure of scrubber life was the combined increase of the three dichloro-biphenyls. Evidently a trace of chlorine gas in the scrubber chlorinates to some extent the absorbed biphenyl and mono-chlorobiphenyls. The FeCls level ranged from 0.017% after 24 hrs. to 0.045% and 0.065% after 2 and 3 weeks respectively. L. H. Horcher dy DS**s189 STLCOPCB4083971 AR-D Report No. 2450 Appendix A Scrubber Liquor Analysis Date Bi0 Z 2^27 2/28 8.00 am 6.00 pm 12 Mid. 0.005 0.028 0.010 0.005 3/6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 29 30 31 4/1 8.00am 1.00 pm 8.00am 2.00pm 0.010 0.033 0.026 0.021 0.032 0.015 0.018 0.016 0.004 0.007 0.010 0.013 0.009 0.010 0.009 0.003 0.005 0.004 0.003 0.001 0.004 0.010 0.016 0.011 0.008 0.009 0.011 0.012 oClBi0 % ._ mClBi0 Z ----- 0.240 0.323 0.367 0.308 0.281 0. 303 0.315 0.214 <10.100 <0.001 0.003 0.002 0.004 <0.001 <0.001 0.003 0.243 0.281 0.251 0.286 0. 325 0.331 0.345 0.325 0.332 0.281 0.221 0.175 0.184 0.226 0. 262 0.269 0.275 0.268 0.372 0.352 -. <0.001 <0.001 <0.001 <0.001 <0.001 0.006 0.001 <0.001 0.001 0.002 <0.001 CO.001 <0.001 <0.001 <0.001 0.001 <0.001 <0.001 <0.001 <0.001 ClBi0 % _- ^ "-- 0.020 0.071 0.084 0.066 0.060 0.057 0.048 0.047 0.030 0.022 0.022 0.029 0.046 0.042 0.039 0.027 0.033 0.020 0.009 0.002 0.011 0.027 0.031 0.036 0.014 0.029 0.039 0.041 April 24, 1974 monoClBi0 Z 0.025 0.170 0.221 0.217 0.260 0.394 0.454 0.376 0.345 0.360 0.363 0.264 0.273 0.303 0.273 0.315 0.371 0.379 0.385 0.352 0.366 0.304 0.230 0.177 0.195 0.253 0.293 0.306 0.289 0.297 0.411 0.393 DiClBi0 Z - -- 0, 388 0.442 0.395 0.458 0.543 0.311 0.381 0.425 0.381 0.396 0.400 0.411 0.424 0.425 0.450 0.491 0.490 0.483 0.442 0.502 0.525 0.548 0.584 0.495 0.751 0.622 (1) this includes on the first three DiClBin isomers. ------------ -................. -- - ................. --- --. .. DSW 345190 STLCOPCB4083972 AR-D Report No. 2450 Appendix B April 24, 1974 EC/GC Analysis of Off-Gas Drowning Water Date of Test 3/12/74 Time 1.30 pm - 60 min. MCS-1221 thru 1254 0.69 ppm 2.00 pm - 90 min. 0.60 ppm 2.30 pm - 120 min. 0.69 ppm Date of Test 3/20/74 MCS-1221 thru 1254 Time 2.05 pm - 100 min. 3.44 ppm 2.45 pm - 140 min. 3.27 ppm 3.25 pm - 180 min. 3.04 ppm Date of Test 3/29/74 MCS-1242 - 1254 (1) Time 2.00 pm - 60 min. 7.16 ppm 2.30 pm - 90 min. 3.11 ppm 3.00 pm - 120 min. 1.19 ppm Date of Test 4/2/74 MCS-1221 thru 1242 (2) Time 12.00 noon - 60 min. 2.57 ppm 12.30 pm - 90 min. 1.47 ppm 1.00 pm - 120 min. 1.38 ppm MCS-1109 0.69 ppm 0.09 ppm 0.10 ppm mcs-:1109 0.23 ppm 0.34 ppm 0.47 ppm MCS- 1109 1.11 ppm 0.55 ppm 0.39 ppm MCS- 1109 0.47 ppm 0.90 ppm 1.18 ppm (1.) No MCS-1221 present in these samples (2) No MCS-1254 present in these samples DSW 345191 STLCOPCB4083973 Monsanto REFERENCE TO ' : K. L. Schutzenhofer - WGK January 16, 1976 Analysis of Liquid from HC1 High Line ce H. J. Horner J. A. Gloeckner G. L. Johnson (Dept.246) The following results were obtained on the analysis of the liquid sample taken from the HC1 High Line at 10il5 `am on 1/15/76. Test H20 pH (5%solution) Chlorophenols Iron Result 16.4% 0.5 none detected 22.2% (as Fe) 64.6% (as FeCls) The sample had to be diluted with water to a 5% solution before a pH measurement could be made. These analyses indicate that the material is essentially FeCl3, HC1 and H20. Reference - WGK AR-D Notebook p.20828. dy DSW 345192 STLCOPCB4083974