Document rBEYkjnjQD27qGpJ3jYYweLGE
UJV-'O'I/? #5#
INDUSTRIAL HYGIENE RESULTS
DATE: PROJECT:
DATE OF SAMPLES:
April 6, 1987.
Monitor insulators removing asbestos insulation using the glove bag technique. SSP Unit. K-36, top deck.
January 16, 1987.
SAMPLE
Z-8872 Z-8873
TIME START
10:34 14:31
TIME STOP
11:30 15:29
RESP?
Airline Airline
C0NC.
0.158 fibers/cc 0.272 fibers/cc
DISCUSSION:
METHOD OF ANALYSIS: DATA AND REPORT BY: COPY TO:
Both of the above exposures were unexpectedly high. Since these exposures do not typically extend for 8 hours, but rather 4 one hour exposures, it is doubtful that an overexposure condition was experienced. This, however is only true if during breaks, lunch, etc. the insulator is not exposed to any asbestos (which should be the case). In addition, airline respirators were worn. The above stated protective equipment and work schedule should however in no way diminish the impact of these results. I would recommend that we closely scrutinize if the glove bag method of removal is being used properly. The above results indicate Chat wetting must be used in conjunction with the glove bag. The high concentrations measured are most likely a result of fibers being released during removal of the glove bag from the line. Since this is the most probably time for release of fibers, the glove bag should be thoroughly wetted and evacuated with the HEPA vacuum before removing it from the line. It is very important that I.H. be called to perform monitoring during similar situations in order to ascertain if these high concentrations are the norm or if this was an isolated incident.
Microscopy
T. L. Grittie
45^ A. Boggs, E. L. Doerflein, T. K. Ioannou, J. K. Kyle, F. M. Plechaty, W. V. Summers, K. B. Purinton, G. W. Wulfert.
TLG/le 5446A
UCC 002051
OJit'O-i-f? 3^
INDUSTRIAL HYGIENE RESULTS
DATE:
April 6, 1987.
PROJECT:
Monitor contract personnel and area under roof of Polymers I for asbestos. Transite was being removed from the Poly I roof by Tri-State employees.
DATE OF SAMPLES:
1/20/87 and 1/21/87
SAMPLE
TYPE
TIME START
TIME STOP
RESPIRATOR?
RESULTS
DATE
Z-8885
BZ
14:38
15:43
Comfo 11 HEPA filter
0.074 fiber/cc
1/20
Z-8886
BZ
14:40
15:42
Comfo II HEPA filter
0.160 f/cc
1/20
2-8887
A
14:42
15:45 N/A
0.070 f/cc
1/20
Z-8888
A
08:26
15:34 N/A
0.004 f/cc
1/21
BZ " Breathing Zone A " Area
DISCUSSION:
All samples were below the OSHA permissible exposure limit. The removal of the transite took less than two hours on- both of these days. Z-8886 was above the action level during the monitoring period, but below the PEL. On 1/21/87 area monitoring was performed for 7 hours 8 minutes while the same type work was being performed. This was done to assure that operators entering the area below the roof repair were not being overexposed. As the results of sample Z-8888 indicate there was little to no exposure potential in the area. It also serves to illustrate that when monitored over an 8-hour period the exposure potential did indeed decrease at the end of the time period in which the transite was being removed.
RECOMMENDATIONS:
Continue to use respiratory protection as a precautionary measure until more samples may be taken to assure that the PEL is not exceeded. Request I.H. monitoring any time work on transite is being performed to obtain more background data.
METHOD OF ANALYSIS:
Microscopy
DATA AND REPORT BY:
C. R. McMillan/T. L. Crittie
ANALYSIS BY:
Kemron Environmental.
COPY TO:
l'D. A. Boggs, J. E. Boley, E. L. Doerflein, T. K. Ioannou, L. P. Smith, W. V. Summers, G. W. Wulfert. F. M. Plechary
TLC/le 5458A
UCC 002052