Document rB8KBxMELGRRnBme42mBnw3or
FOR TOP PERFORMANCE
the new ARCOFLAME
model ES-2 Shell Head Oil Burner
CLEAN, HIGHLY EFFICIENT OPERATION
incorporates improved Shelf Designed Combustion
Head; bums No; 1 and No. 2 fuel oil, catalytically
cracked or distillate, cleanly and completely, resulting
in high operating economy--no soot, no smoke, no
fumes.
"''T?/'';,.' :
:
PRACTICAL SIZE RANGE............................70 to 1.50 gph capacity provides efficient combustion with minimum excess, air--in capacity range where Shell Head is in greatest demand.
QUICK, EASY MAINTENANCE......................... standard fuel unit,'transformer, fan and motor mean quick, easy servicing.
FAST, LOW-COST INSTALLATION.........................modem design and sturdy lightweight steel construc tion mean easy handling, fast installation.
FULLY TESTED.........................ES-2 burner field, laboratory and factory tested to meet rigid American-Standard requirements; listed by Underwriters' Laboratories, Inc.
THREE CONVENIENT MOUNTINGS.........................pedestal, flange or hanger mountings adapt burner to all installations.
CHOICE OF AIR TUBE LENGTHS........................ 8", 15" and 23 'nominal air tube lengths available for all conversion jobs; 6JA' effective tube length for American-Standard oil heating units.
SIMPLIFIED ADJUSTMENTS.........................externally-operated controls permit precision adjust ments to be made while burner is running; easier and more accurate setting, improved flame stability.
ATTRACTIVE APPEARANCE........................ Forge Red and black finish, chrome trim strips and American-Standard Mark of Merit enhance burner's
appearance.
POSITIVE PERFORMANCE........................ burner has single shaft for fuel unit, fan and motor with flexible coupling; statically and dynamically bal
anced fan.
/
l'9*0C V 'lV
Method of Fuel Atomization-- Mechanical Pres sure--100 pounds.
Delayed Opening Solenoid Oil Valve--Provides smooth, dean starts and quick, clean stops. Eliminates soot deposit.
Air Supply--Low pressure with squirrel cage fan.
Nozzle--Each nozzle checked at factory for proper spray angle.
Ignition--Intermittent or constant spark.
Shell Designed Combustion Head--4-inches in diameter with cast iron end cone.
Approval--All Arcoflame Oil Burners (60 cycle, 115 volt) are listed by Underwriters' Labora tories, Inc. for No. I and No. 2 grades of fuel oil, distillate or catalytic cracked, and comply with Commercial Standard CS-75. They are approved by the New York City Board of Standards and Appeals, the State Fire Marshall of the Commonwealth of Massachusetts and the Department ofState Police, StateofConnecticut.
12*4
-17*4
Dimensions (Inches)
Modal
A B
ES7-4 ES-2-1 ESMJ tS-2-23
1514 16*4 23*4 31*4 6*4 8 15 23 Oiamttar Airtube--4*
SPECIFICATIONS MODEL ES-2
CURRENT CHARACTERISTICS
GALLONS OIL PER HOUR
MAXIMUM* INSTALLED RADIATION SO. FT.
MOTOR
115 volt
Minimum
Maximum
Steam
Water
hp
rpm
60 cycle
.7 1.50 400 650 /. 1.750
*These capacities can be used up to 1,000 feet altitude. Reduce capacities bjr 6% (or each additional 1,000 feet
ARCOFLAME Standard Control Sets
GAL PER NR.
.75 .85 1.00 1.10
NOZZLES AND STRAINERS
When ordering nozzles, be sure to specify Hollow Cone Nozzle and size desired.
SPRAY ANGLE
GAL. PER HR.
80 1.25 80 1.35 80 1.50 80'
SPRAY ANG
80 80 80
New Arcoflame Model ES-2 Oil Burners are sold only in combination with one of the standard Arcoflame Control Sets listed here. All controls are noted for their precision manufacture and dependable performance.
CONTROL SET NUMBER
No. 11 STEAM
For Boiler WITHOUT Year-Round Domestic Hot Water.
No. 12 STEAM
For Boiler WITH Year-Round Domestic Hot Water Builtin Heater.
No. 13 WATER No. 14 WATER No. 15 WATER
For Boiler WITHOUT Year-Round Domestic Hot Water. Immersion Control for New Boilers.
For Boiler WITHOUT Year-Round Domestic Hot Water. Clamp-on Control for existing boiler.
For Boiler WITH Year-Round Domestic Hot Water Builtin heater; using circulator.
No. 16 WATER
For Boiler WITH Year-Round Domestic Hot Water Builtin tankless heater; using circulator.
No. 16-Z WATER No. 19 WARM AIR
2-zone control, for boiler WITH Year-Round Domestic HOT WATER; Built-in tankless heater; using circulators. NOTE; For each additional zone, add 1 No. CA-412 thermostat and 1 No. CA-295 relay transformer, at current prices.
For Gravity Furnace.
No. 20 WARM AIR For Forced Warm Air Unit
CONTENTS OF ARCOFLAME CONTROL SET
CA-412 450-BA-l
. Tuned Cycling Thermostat Pressure Limit Control
CA-412 450-BA-l CA-666
Timed Cycling Thermostat - Pressure Limit Control Immersion Operating Control
CA-412 CA-665
Timed Cycling Thermostat Immersion Limit Control
CA-412 251-MJ
Timed Cycling Thermostat Clamp-on Limit Control
CA-412 CA-655 CA-666 CA-295
Timed Cycling Thermostat Immersion Limit Control Immersion Operating Control Relay Transformer
CA-412 . CA-655 CA-666-DT CA-295
Timed Cycling Thermostat Immersion Limit Control Immersion Control Double Throw Switch Relay Transformer
2 CA-412 CA-655 CA-666 CA-666-R 2 CA-295
Timed Cycling Thermostats Immersion Limit Control Immersion Operating Control . , Reverse Acting Low Limit Control Relay Transformers
CA-412 CA-805
Timed Cycling Thermostat Limit Control
CA-412 CA-815-S
Timed Cycling Thermostat Fan and Limit Control
plumbing and heating division
AMERICAN RADIATOR A STANDARD SANITARY CORPORATION NEW YORK 18, NEW YORK
00071