Document rB8KBxMELGRRnBme42mBnw3or

FOR TOP PERFORMANCE the new ARCOFLAME model ES-2 Shell Head Oil Burner CLEAN, HIGHLY EFFICIENT OPERATION incorporates improved Shelf Designed Combustion Head; bums No; 1 and No. 2 fuel oil, catalytically cracked or distillate, cleanly and completely, resulting in high operating economy--no soot, no smoke, no fumes. "''T?/'';,.' : : PRACTICAL SIZE RANGE............................70 to 1.50 gph capacity provides efficient combustion with minimum excess, air--in capacity range where Shell Head is in greatest demand. QUICK, EASY MAINTENANCE......................... standard fuel unit,'transformer, fan and motor mean quick, easy servicing. FAST, LOW-COST INSTALLATION.........................modem design and sturdy lightweight steel construc tion mean easy handling, fast installation. FULLY TESTED.........................ES-2 burner field, laboratory and factory tested to meet rigid American-Standard requirements; listed by Underwriters' Laboratories, Inc. THREE CONVENIENT MOUNTINGS.........................pedestal, flange or hanger mountings adapt burner to all installations. CHOICE OF AIR TUBE LENGTHS........................ 8", 15" and 23 'nominal air tube lengths available for all conversion jobs; 6JA' effective tube length for American-Standard oil heating units. SIMPLIFIED ADJUSTMENTS.........................externally-operated controls permit precision adjust ments to be made while burner is running; easier and more accurate setting, improved flame stability. ATTRACTIVE APPEARANCE........................ Forge Red and black finish, chrome trim strips and American-Standard Mark of Merit enhance burner's appearance. POSITIVE PERFORMANCE........................ burner has single shaft for fuel unit, fan and motor with flexible coupling; statically and dynamically bal anced fan. / l'9*0C V 'lV Method of Fuel Atomization-- Mechanical Pres sure--100 pounds. Delayed Opening Solenoid Oil Valve--Provides smooth, dean starts and quick, clean stops. Eliminates soot deposit. Air Supply--Low pressure with squirrel cage fan. Nozzle--Each nozzle checked at factory for proper spray angle. Ignition--Intermittent or constant spark. Shell Designed Combustion Head--4-inches in diameter with cast iron end cone. Approval--All Arcoflame Oil Burners (60 cycle, 115 volt) are listed by Underwriters' Labora tories, Inc. for No. I and No. 2 grades of fuel oil, distillate or catalytic cracked, and comply with Commercial Standard CS-75. They are approved by the New York City Board of Standards and Appeals, the State Fire Marshall of the Commonwealth of Massachusetts and the Department ofState Police, StateofConnecticut. 12*4 -17*4 Dimensions (Inches) Modal A B ES7-4 ES-2-1 ESMJ tS-2-23 1514 16*4 23*4 31*4 6*4 8 15 23 Oiamttar Airtube--4* SPECIFICATIONS MODEL ES-2 CURRENT CHARACTERISTICS GALLONS OIL PER HOUR MAXIMUM* INSTALLED RADIATION SO. FT. MOTOR 115 volt Minimum Maximum Steam Water hp rpm 60 cycle .7 1.50 400 650 /. 1.750 *These capacities can be used up to 1,000 feet altitude. Reduce capacities bjr 6% (or each additional 1,000 feet ARCOFLAME Standard Control Sets GAL PER NR. .75 .85 1.00 1.10 NOZZLES AND STRAINERS When ordering nozzles, be sure to specify Hollow Cone Nozzle and size desired. SPRAY ANGLE GAL. PER HR. 80 1.25 80 1.35 80 1.50 80' SPRAY ANG 80 80 80 New Arcoflame Model ES-2 Oil Burners are sold only in combination with one of the standard Arcoflame Control Sets listed here. All controls are noted for their precision manufacture and dependable performance. CONTROL SET NUMBER No. 11 STEAM For Boiler WITHOUT Year-Round Domestic Hot Water. No. 12 STEAM For Boiler WITH Year-Round Domestic Hot Water Builtin Heater. No. 13 WATER No. 14 WATER No. 15 WATER For Boiler WITHOUT Year-Round Domestic Hot Water. Immersion Control for New Boilers. For Boiler WITHOUT Year-Round Domestic Hot Water. Clamp-on Control for existing boiler. For Boiler WITH Year-Round Domestic Hot Water Builtin heater; using circulator. No. 16 WATER For Boiler WITH Year-Round Domestic Hot Water Builtin tankless heater; using circulator. No. 16-Z WATER No. 19 WARM AIR 2-zone control, for boiler WITH Year-Round Domestic HOT WATER; Built-in tankless heater; using circulators. NOTE; For each additional zone, add 1 No. CA-412 thermostat and 1 No. CA-295 relay transformer, at current prices. For Gravity Furnace. No. 20 WARM AIR For Forced Warm Air Unit CONTENTS OF ARCOFLAME CONTROL SET CA-412 450-BA-l . Tuned Cycling Thermostat Pressure Limit Control CA-412 450-BA-l CA-666 Timed Cycling Thermostat - Pressure Limit Control Immersion Operating Control CA-412 CA-665 Timed Cycling Thermostat Immersion Limit Control CA-412 251-MJ Timed Cycling Thermostat Clamp-on Limit Control CA-412 CA-655 CA-666 CA-295 Timed Cycling Thermostat Immersion Limit Control Immersion Operating Control Relay Transformer CA-412 . CA-655 CA-666-DT CA-295 Timed Cycling Thermostat Immersion Limit Control Immersion Control Double Throw Switch Relay Transformer 2 CA-412 CA-655 CA-666 CA-666-R 2 CA-295 Timed Cycling Thermostats Immersion Limit Control Immersion Operating Control . , Reverse Acting Low Limit Control Relay Transformers CA-412 CA-805 Timed Cycling Thermostat Limit Control CA-412 CA-815-S Timed Cycling Thermostat Fan and Limit Control plumbing and heating division AMERICAN RADIATOR A STANDARD SANITARY CORPORATION NEW YORK 18, NEW YORK 00071