OOD AND DRUG AD AM NIST RATI ON COMPLIANCE PROGRAM GUIDANCE MANUAL
PROGRAM 7306.02
CHAPTER 6 - DAIRY INDUSTRY
Progrom Activity: Surveillance, Compliance
Data Control Code: BF-320-024
Problem Code: FH-18
Commodity Code: 17
Project Code: 05
SUBJECT: SURVEY: POLYCHLORINATED BIPHENYLS IN MILK
PURPOSE
.
To provide guidance to the districts in conducting a survey of fluid milk for the polychlorinated biphenyls.
BACKGROUND
'
In 1970 PCB's were detected in milk samples from West Virginio. Follow up investigation revealed the apparent misuse of an electrical transformer fluid containing PCB as a vehicle for defoliant spraying operations adjacent to dairy pasturage as being responsible for the milk contamination. PCB's have also been found to be a component of sealants used to treat silos on dairy farms. Milk contamination has resulted from this source of PCB's.
Subsequent information derived from the total diet studies program, the general pesticide program, and oilier food surveys has shown the presence of PCB's in fish, milk, eggs, in grayboard used in cereal packaging materials and in the cereal product itself.
Surveys to date reveal that additional data is necessary to determine the extent of PCB occurrence in milk. Information is desired to determine the condition of milk used for battling purposes ond milk used for manufacturing purposes with respect to PCB contamination.
For the purpose of this survey "bottling milk" is milk which is destined for pasteurization and subsequent bottling for direct consumer use. "AAanufucturing milk" is milk intended for use as a row material in the production of a consumer dairy product (e.g., NFDM, condensed milk, cheese, butter, and ice cream).
OBJECTIVE
To survey the milk supply on a state by state basis to determine the extent of PCB contamination of milk for bottling and manufacturing use.
THANSMIT1AL MO.
72-8 (2/J/72)
omc.iMAioH Bureau of Foods, Division of Compliance Programs, Program Development Brunch, BF--323
PAC.S 1
MGNS 093530
PROGRAM 7306.02
APPROACH
1, Inspcctionol
Districts ore responsible for follow-up investigations including inspections if necessary to determine the source of any PCB contamination delected.
The Districts should work with the Regional Milk and Food Consultants and state and local officials to determine sampling sources and to facilitate follow-up activities.
There will be no CP-IP issuance by EDRO for this program.
2. Sample Collection
The attached district/state sampling schedule has been developed from available information regarding the milk production of edch state for both bottling and manufacturing use. Districts should make every effort to collect the samples as specified and to distinguish between milk for bottling and milk for manufacturing use. It is recognized that in some instances the latter will not be possible.
Sampling sources should be selected on a random basis to reflect milk production
and usage within each state. Samples may be collected from both interstate and
intrastate sources.
Bottling Milk Manufacturing
District ATL-DO
State * Georgia
Samples 40
5
Milk Samples 12
-
Total Samples 52 5
Florida Alabama Mississippi
7 -7 314 41 5
Tennessee
6 39
North Carolina
6
1
7-
South Carolina
3
2
5
Kentucky
6 4 10
BLT-DO
Maryland Virginia West Virginia
13 6 6 1
3 16 17 17 12
TRANSMITTAL NO. 72-8 (2/3/72)
PAOE 2 MOMS 093531
District BOS-DO
State
Maine ' New Hampshire Vermont Rhode Island Connecticut Massachusetts
BUF-DO
New York
CIN-DO
Ohio
CHI-DO
Illinois
DAL-DO DEN-DO
New Mexico Oklahoma Texas
"/
North Dakota South Dakota Montana Wyoming Colorado Utah
DET-DO
Michigan Indiana
KAN-DO rMAN&MI TTAL NO
Iowa Nebraska Kansas Missouri
72-8 (2/3/72)
PROGRAM 7306.02
Bottling Milk Samples
19 2 1 9 1 3 3
46 46
17 17
9 9
19 1 5 13
9 1 1 1 1 3 2
27 18 9
22 6 3 5 8'
Manufacturing Milk Samples Total Samples
0 19 - '2 > -1 -9 -1 -3 -3
0 46 - 46
2 19 2 19
4 13 4 13
1 20 - 1' 16 0 13
II 20 23 56 12 12 14 13
5 32 3 21 2 II
23 45 13 19 36 27 5 13
PAGE 3
MONS 093532
PROGRAM 7306.02
District LOS-DO MIN-DO NOL-DO . NYK-DO
PHI-DO SAN-DO
SEA-DO
State
California Arizona
Minnesota Wisconsin
Loulsana Arkansas
New York New Jersey Puerto Rico Virgin Island
Pennsylvania Delaware
* California Nevada Hawaii
Washington Idaho Oregon Aloska
Bottling Milk Samples
. 20 18 2
' 51
10 41
7 v5
2
5
3
1 1
30 29
1
20
18
1 1
15
9
2
3 1
Manufacturing Milk Samples Total Sampl
2 2'
0
.22 20
2
71 122 32 42 39 80
18 -5
13
27
.-
0
-3
1 (if available) 2
1 (if available) 2
i 31 i 30 -1
2 22
2 20
-1 -1
6 21 - 9. 57 14
1
Totals
369 146 515
TNANSMITTAL NO. 72-8 (2/3/72)
`AC.k 4 MONS 093533
PROGRAM
7306.02
I
--------------------------------^------ --------------- --------- ---------- J---------1
Samples should consist of,quarts of fluid milk collected from route collection trucks (bulk form milk pick-up) on completion of pickup or from collection station points prior to further dilution of the mi Ik at the processing plant. If milk is received in cons at the processor, samples should be collected from the holding tanks prior to process.
Plastic containers or containers in which the contents come into contact with rubber or cardboard closures or inserts should not be used in the collection of samples for PCB analysis. One quart Mason jars, which have been washed to rinse out cardboard particles or other foreign matter which may interfere with PCB analysis, may be used. Tin foil should be inserted beneath the jar lid and screw top to prevent milk contact with the rubber gasket.
Aseptic technique (sterile ladles) should be used in collecting samples for this survey to avoid adding to the bacterial load of the bulk milk from which the sample is collected.
Samples may be official or investigational. ^Collection reports should be flagged "PCB Milk Survey" ond should include the following information.
'
I. State where collected. 2. Point of collection (e.g., route truck, holding tank, etc.). 3. Volume of milk sampled. 4. Number of producers represented. 5. Type of milk (e ,g., bottling, manufacturing). 6. Milk route number or palron(s) can number. 7. Route truck number or license number.
`
See Inspector Operations Manual, Chapter 4, Sections 443.2, 452.2, 454, and 454.3 for guidance in samp to hand ling, shipment, and notification of receiving laboratory.
3. Sample Analysis
Analyze samples for PCB, organochlorine and organophosphorus pesticide residues using appropriate PAM Vol. I methodology for extraction, cleanup, and GLC determination; extraction 2ll.l3h(l) (4/1/71 revision) cleanup, 211.14a,d (4/1/71 revision); EC-KCLTD GLC, 321. Inject approximately 3 mg milk fat equivalent for GLC. Analyze 20% of the District somple quota (with a minimum of four samples) for the chlorophcnoxy acid residues.
Determine residues of pesticides in the usual manner. Evaluate cC-GLC chromatogram of 6% F lori si I eluatc for presence of PCB anJ pesticides. If presence of PCB is indicated, complete analysis using the necessary treatment of extract prior lo GLC determination.
TRANSMITTAL VO. 72-8 C 2/3/72)
I'AG II 5
MONS 093534
PROGRAM
7306.02
i
In most instances when both PCB and DDT and analogs are present, the PCB and organachlorine pesticides require separation by chromatography on silicic acid (Armour and Burke, JAOAC 53, 761 (1970)) prior to determination. In some instances dehydrochlo rination of DDT and TDE to their respective olefins (Sawyer and Krause, LIB 1249 .(Jon. 8, 1971)), or a combination of dehydrothlorlnation followed by oxidation of olefins to the respective dichlorobenzophcnone (Mu I hern, ct a!, JAOAC 54, 548 (1971)) will permit quantitation of PCB without.column chromatographic separation.
Appropriate treatment will depend on the PCB (Aroclor(s)) indicated present, the particular pesticide(s), and the relative amounts of PCB and pesticides, Aroclors 1221, 1232, and 1242 divide between the petroleum ether and polar solvent eluoies from the silicic acid column, but residues of these Aroclors con possibly be quantitated in the presence of DDT and analogs, and would not necessarily require column chroma tographic separation from these pesticides.
Previous experience indicates that PCB residues in cows' milk will be more similar in GLC pottern to Aroclors 1254 or 1260.
Quontitate PCB residues by electron capture GLC or by use of halogen specific microcoulometric or electrolytic conductivity GLC detectors. Compare the total area response from the PCB residue to the total area response from a known weight of the Aroclor with most similar GLC pattern. However, if the GLC curve shows that the PCB residue clearly consists of components of more than one Aroclor, if possible quantitate the residues separately using tire appropriate Aroclor reference for the respective portion of the GLC curve.
When PCB residue is 5 ppm or above in the fat, confirm residue identity by GLC with halogen specific microcoulometric or electrolytic conductivity detectors and/or demonstration of the residue's stability to boiling alkali. Additional confirmatory analyses are left to discretion of the Laboratory Director.
Limit of detection for PCB residue in milk fat is approximately 1.5 ppm (as Aroclor 1254), when using a 3 mg sample injection and EC-GLC operated at the above conditions.
Report PCB residue in terms of Aroclor(s) used in quantitation (e.g., 2 ppm Aroclor 1242 and 3 ppm Aroclor 1260).
PCB residue levels in milk fat should be rounded off to the nearest 0.1 ppm.
TRANSMITTAL NO.
72-8 (2/3/72)
p a r. c 6
MQNS 093535