Attached Is a copy of Mr. J. P. Llcata's survey
report of your facility June 21, and 22, 1976.
We were pleased to note that all recommendations
submitted by Mr. R. T. Richards In his October, 1975 report
have been completed.
Should you have any questions concerning this re
port, write R. T. Richards of the Health Division with a
copy of correspondence to this office.
Attachment
J. M. SEAMANS
WA-TEX 000019
iiwi
T E3 X. A. C O New York, Now York 10017
August 24, 1976
f^L
INDUSTRIAL HYGIENE SURVEY PUGET SOUND PIA
MEMORANDUM
J, M. Seamans Houston, Texas
Attached is the original and one copy of the subject report of a survey performed by J. P. Licata, Industrial Hygienist, Health Division, New York. It is assumed that you will forward the attached copy to the Puget Sound Plant.
If you or Mr. Templeton have any questions regarding tills report, please let me know.
RTR:dg Attachment
bcc:
JPL HLH DMM WD
R. T. Richards
| WA-TEX 000020
:atz;ttai,ar.jrnytiniiajMfi :tar
INDUSTRIAL HYGIENE SURVEY
PUGET SOUND PLANT
ANACORTES. WASHINGTON
JUNE 21 it 22, 1976
By: James P. Licata, Industrial Hygienist Health Division, New York
SUMMARY
Asbestos wicking in storehouse should be in a sealed labeled plastic bag. Turco Transpo Cleaner, a severe eye hazard, should have portable eye wash available where cleaner is used. Self-contained breathing apparatus should be located near anhydrous ammonia cylinders at VPS. All gas mask canisters should be attached to masks ready for instant use. Additional exit signs are required in the foremen's office building.
RECOMMENDATIONS
1. Asbestos wicking, tape or other asbestos fabricated materials stored on shelves in the storehouse should be in sealed,. properly labeled plastic bags to avoid airborne fibers.
2. Turco Transpo Cleaner is used in many areas of the plant. This
cleaner is a severe eye hazard and a portable pressurized eye
wash should be part of the employes safety equipment when using
this material.
,
3. A self-contained breathing apparatus should be located near the anhydrous ammonia cylinders at the VPS. A copy of the current MCA (Manufacturing Chemists Association) Data Sheet is attached.
4. All gas mask canisters on station throughout the plant should be connected to the face masks ready for instant use.
5. Additional exit signs are required inside the foremen's office building to comply with Federal Register OSHA 1910.36.
DISCUSSION
During the survey of the plant the recommendations submitted by Mr. R. T. Richards from his report dated October 1975 were reviewed with Mr. J. Drummond, Safety Supervisor. All of the recommendations have been completed.
WA-TEX 000021
The audiometric booth was surveyed with a General Radio, Model 1933
Precision Sound Level .Meter to insure that the booth conforms to the ANSI
(American National Standards Institute) Standard S 3.11960/1971 for noise attenuation.
A separate data sheet. Table 1, is attached. As can be seen from Table 1, the
booth does not meet the ANSI standard of 30 dB at the 12S Ha frequency when the
exhaust fan is operated. The fan is and should not normally be used during audio
metric testing procedures.
-
I wish to thank Mr. P. C. Templeton and his staff for their assistance
and cooperation during my visit.
,
J. P. Licata
WA-TEX 000022
TABLE I
PUGET SOUND PLANT * AUDIOMETRIC BOOTH INTERIOR NOISE SURVEY
Audiometvic Test Freauencv Hz
Sound Pressure Levels (dB)
Sound Pressure Levels (dB)
ANSI S 3.1 1960/1971
125 250 500 1000 2000 4000 8000
*
27 13 < 10 <10 <10
12 12 Exhaust fan off
38 27 18 12 10
12 12 Exhaust fan off
30 30 30 30 37
47 57
The ANSI Standard S 3.1 was approved in I960 and re-affirmed on 4/27/71 by the American National Standard* Institute.