Document r9gx4rmew9Oe3O95n45ZBLya
Air Conditioning gmfS 0Sten*"`
Hayes Furnace Mfg. & Supply Co.
2929 South Fairfax Ave., Los Angeles 16, Calif.
(Telephone Texas 0-3734)
Contact Nearest Representative
Associated Refrigeration En&rs., Montgomery, Ala. M. Blazer A Son, Passaic, N. J. Blue Flame Supply Co., Atlanta, Go. Eugene Bolstad, Edmonton, Alberta, Canada E. B. Bomar, Phoenix, Arizona Boyd Engineering Co., Albuquerque, New Mex.,
and El Paso, Texas Dealers Supply Co., Atlanta, Go. Reube 0. Emery, Nashville, Tenn
Jewell A Co., Hot Springs, Ark.
Leudecke Engineering Co., Austin, Texas Homer Maxey A Co., Lubbock, Texas
McCombs Supply Co., Denver, Colo. Noland A Co., Newport News, Va. O'Connor-0klahoma Co., Oklahoma City, Tulsa,
Okla., and Wichita, Kansas Smith Steam Specialty Co., Kansas City, Mo. Tay-Holbrook, Inc., San Francisco, Califr
F. R. Young, Houston, Texas :
DUCT FURNACES
Constructed of Type 321 Stabilized Stainless Steel. Non-cor rosive property of heat exchanger permits installation down stream of cooling coils or washer. Heat exchanger will not corrode when subjected to continuous ventilation during the summer season. Designed for continuous blower operation for offices, theaters, schools, churches, factories. Air throughput in either direction. Draft Hood and Vent Manifold reversible, adjustable for both horizontal and vertical connection, 14 sizes, 80,000 to 600,000 Btu per hr input in 40,000 Btu incre ments. A.G.A. certified for all gases.
MODEL SED-E
Non-corrosives type 321 stainless steel heat exchanger. Per mits installation downstream of cooling equipment, for con tinuous blower operation. Air throughput in either direction. 80,000 to 600,000 Btu input.
MODEL SED-S
Same as SED-E except controls are at the side, instead of at the end where accessibility requires. SED-S is available in sizes from 80,000 to 600,000 Btu input in increments of 40,000 Btu.
Both SED-E and SED-S can be used for industrial applica tions for drying.
FORCED AIR FURNACE MODEL SEC
Heat exchanger constructed of identical die formed sections, of type 321 stabilized stainless steel. Sections are seam and arc welded. One piece cast iron burners with drilled, ports. Oversize double inlet blower. Long hour motor. Equipped with glass filters. Can furnish permanent filters at extra cost. Finished in baked silver grey. 6 sizes 70.00Q to 245,000 Btu per hr input in 35,000 Btu increments. For natural, manufactured and L.P. gases. Can be used for 0 clearance
ALL HAYES FURNACES ARE A.G.A. APPROVED 1252
Hayes Furnace Mfg. & Supply Co.
Air Conditioning gfjgS SggTM*
DUCT FURNACE MODEL
SED-VF
Tested and approved as a DUCT FUR NACE--Constructed of type 321 sta bilized stainless steel. Re-circulated or fresh air is introduced through bottom, sides or back of furnace. Equipped with air bypass. Handles large cfm per Btu input. Vent in front of furnace. Made in 6 sizes from 70,000 to 245,000 Btu per hr input in increments of 35,000 Btu. For natural, manufactured and L.P. gases.
FORCED AIR SUSPENDED FURNACE, MODEL SES
Equipped to install in a suspended duct system. Inlet and outlet designed for sheet metal duct connection.
UNIT HEATER MODEL SEU
Used where room air is to be recircu lated. Diffuser outlet with adjustable vertical and horizontal vanes. Both types of Suspended units are designed for factories, commercial and other large Btu requirements -- equipped with brackets for suspension, save floor space. Double inlet forward curve blower. Continuous duty variable pitch drives; cast iron, raised port, precision ma chined burners. Made in sizes 80,000 to 600,000 Btu per hr input in 40,000 Btu increments. For natural, manufactured and L.P. Gas.
...... .*.vvw* w vuuiaiui
Centrifugal backwardly curved blower type . . . the blower wheel cannot be overloaded regardless of length or curves in the duct or variation in design. It is belt driven to provide flexibility. The ventilator is mounted on a built up curb on the roof. Special features in clude low profile with streamlined de sign and a corrosion resistant housing. The motor and fan bearings are grease
packed ball bearings and are out of the air stream. A manually operated safety cutoff switch is provided.
DIMENSIONS
UNIT
SIZE A B c
1000 1200
1300 1600
1800 2000 2200 2400 -2700 3000 3300 3600 4000 4400 4900 5400
24M 15)4 11)4 28 . 17)4 13 29 24 H 13)4 35)4 25)4 16)4 39M 27)4 20 43 .30 20 46H 30)4 22)4 49)4 32)4 25 55)4 3444 28 60)4 36)4 31 66 40 33)4
42)4 40)4 85 4554 40 eon 49 44)4 tSH 54 50 108 57M 1 55
D
19)4 21 21
24)4 28 28 30)4 33 36 39 41
48)4 52 56 62 67
E
16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16
APPROX. SHIP. WT.
130 137 180 275 300
350 500
630 700 795 875 1120 1500 1900