Document r6qVyvX06DenXv6o0xBDZojbv
Controls and Instruments
The Mercoid Corporation i
Main Office and Factory, 4201 Belmont Atenue, Chicago 41, Illinois
New York Office, 205 East 42nd St.
Philadelphia Office, 8137 N. Beoad St.
AUTOMATIC CONTROLS FOR HEATING* AIR-CONDITIONING, REFRIGERATION AND VARIOUS INDUSTRIAL APPLICATIONS
MERCURY SWITCHES BY MERCOID
V /\
/\\
`(till Art** jpflt
Tilting Type
There are three primary operating types
of Mercoid Mercury Switches:--1. MAG
Magnetic Type NETIC TYPE, applied in a sSttaattiioonnary
Light Actuated Type
position. Circuit is opened or closed with magnetic attraction by means of a per
manent magnet or a small milli-ampere electromagnet. 2. TILTING TYPE, a
variety of sizes, electrical capacities and arrangements available. 3. LIGHT
ACTUATED TYPE. These switches are immune to dust, dirt or corrosion.
THE 100% MERCURY SWITCH EQUIPPED CONTROLS
No. t
No. i
No. I
No. 1. Pressure Controls Noted for their accuracy and depend able performance. The outside double adj ustment feature and visible dial eliminate all guesswork when setting the operating
range. Various ranges and circuits available.
No. 8
No. 2. Low Voltage Thermostats Mercoid Sensatherms operate on a total differential of 1 degree F.- Type H is the popular room thermostat. Type DNH is a hand wound day and night thermostat. Type HBH is a two-stage thermostat for control
of high-low gas or oil burners.
No. 3. Temperature Controls Available with or without remote connection for use with liquids or gases such as air, oil, water or distillate vapors. Equipped with a Bourdon tube and outside double adjustments.
No. 4. Lever Arm And Float Controls The lever arm type is used where it is desired to mechanically open and close electric circuits. The float type is used to main tain fluid levels in tanks, or for control of sump pumps, etc.
No. S. Line Voltage Thermostats No. 855 thermostats will directly handle the full motor load without the use of a relay. Available with "on-off" manual switch for
unit heater applications.
No. 6. Low Water Controls Available as a combination pressure and low water con trol or as a low water control only. May be furnished with quick-hook up fittings designed in accordance with the ASME code.
No. 7. Transformer-Relays Type V is a reliable low voltage mercury contact relay which also acts as a transformer inducing low voltage (24 volts) on the pilot circuit. Available in various voltages, cycles and circuits.
No. 8. Vlsaflame Control For domestic and industrial oil burners. from the light of the flame instead of from the heat in the stack. into the burner unit.
1314
Operates direct It may be built
Controls and Instruments
Milwaukee Gas Specialty Company
730 North Jackson St., Milwaukee 2, Wisconsin
BASO* THERMOELECTRIC SAFETY PILOTS
Straight through valves with one pilot tapping each side. Cast, heat treated aluminum alloy bodies with replaceable electromagnetic hood assemblies and reset assemblies. 100 per cent shutoff safe lighting.
A 8H
Model
A814-1 A814-2 A814-3 A505-1 A506-1
Inlet
W F.P.T.
WVS
F.P.T. F.P.T.
F.P.T.
\ys F.P.T.
Outlet
W F.P.T.
F.P.T.
X" F.P.T.
1' F.P.T. 1 F.P.T.
Pilot Tap ping
H* F.P.T. W F.P.T.
F.P.T.
X* F.P.T. W F.P.T.
Capacity Btu/hr.
80,000 101,000 130,000 280,000 329,000
Thermo couple Type
88D 88D 88 D 58D 58D
Straight through low height valves with built in plug cock for main burner and pilot burner control. 100 per cent shut off and safe lighting. With or without pilot adjustment on either side. Model 841 has special plug head for single rod control of floor furnaces. Uses 88D thermocouple lead.
Model
840-1 841-1 A842
Inlet F.P.T.
Y? F.P.T. X* F.P.T.
Outlet
W F.P.T. W F.P.T. X" F.P.T.
Pilot Tapping
w c.c. H' C.C.
Ye" C.C.
Capacity
85,000 85,000 165,000
830 Switch
Electrical Rating: .3 Amps at 250 A.C. .06 Amps at 230 Volts D.C. Uses 88D thermocouple lead
Switch Type Baso is wired in series with automatic gas valve and other controls. Opens circuit to main valve in case of pilot failure. Main burner cannot be lighted until pilot is operating and switch held in closed position.
Basoid valves include in one cast brass body a solenoid valve
for automatic main gas control and a 100 per cent shutoff safety
pilot unit similar to Models A814 or A505. Available in many current types. Two pilot tappings. Series C Basoid in % in. size only.
Model
B4411 B4511 B4451-B1 B4551-B1 C4411
Inlet
X0 F.P.T.
\" F.P.T.
X" F.P.T.
Is F.P.T.
X* F.P.T.
Outlet
Pilot Tap ping
Current Type
Capacity
X* F.P.T.
1* F.P.T.
Xm F.P.T.
1' F.P.T.
X* F.P.T.
W F.P.T.
M' F.P.T. Hm F.P.T.
F.P.T. W F.P.T.
115V, AC
115V, AC 20V, AC
20V. AC 115V, AC
159,000
189,000 159,000
189,000 94,000
Couple Lead Type
58D 58D 58D 58D 88D
Basoid
Reg. U. S. Pat. Off.
ANNULAIR PILOT BURNERS are available in a variety of tips and dual orifice inlet fittings for all kinds of fuel gas and pilot line connections. They are made in four types, "B" for low consumption appliances, "C" for medium consumption, and "D" and "F" for larger capacity appliances. Thermocouple leads of the 88D and 58D types are available in standard lengths from 12 in. to 72 in. and in special lengths to 240 in.
Write for complete catalog SV-300-3.
1315