Document r6mNwYjEj5RVK5kmEN1KwJdyV

j, Lnvironmen! tnvifonncmenl *' Canada Canada Caiiml.i Onliii it) Aiji ci'mrnl on Gu\it l ilacs Walci Quality Ontano Mininii y ol tl H 1 [ f tV'll ( tl II I It 'I 11 STLCOPCB4022145 CANADA-ONTAR10 AGREEMENT RESEARCH REPORTS These RESEARCH REPORTS describe the results of investigations funded under the Research Program for the Abatement of Municipal Pollution within the provisions of the Canada-Ontario Agreement on Great Lakes Water Quality. They provide a central source of information on the studies carried out in this program through in-house projects by both Environment Canada and the Ontario Ministry of the Environment, and contracts with municipalities, research institutions and industrial organizat ions. Enquiries pertaining to the Canada-Ontario Agreement RESEARCH PROGRAM should be directed to - * Wastewater Technology Centre Canada Centre for Inland Waters Environment Canada P.0. Box 5050 Burlington, Ontario L7R 4A6 Ontario Ministry of the Environment Pollution Control Branch 135 St. Clair Avenue West Toronto, Ontario M4V 1P5 DSW 038322 STLCOPCB4022146 POLYCHLORINATED BIPHENYLS (PCB's) IN MUNICIPAL WASTEWATERS: An Assessment of the Problem in the Canadian Lower Great Lakes by E.E. Shannon, F.J. Ludwig and I. Valdmanis Wastewater Technology Centre Environmental Protection Service ENVIRONMENT CANADA RESEARCH PROGRAM FOR THE ABATEMENT OF MUNICIPAL POLLUTION WITHIN THE PROVISIONS OF THE CANADA-ONTAR10 AGREEMENT ON GREAT LAKES WATER QUALITY Project No. 73"3~8 This document may be obtained from Training and Technology Transfer Division (Water) Environmental Protection Service Environment Canada Ottawa, Ontario K1A 0H3 Ontario Ministry of the Environment Pollution Control Branch 135 St. Clair Avenue West Toronto, Ontario M^V IPS DSW 038323 STLCOPCB4022147 f Supply and Services Cat. No. EnA 3- I 1/A9 Canada 1976 ISBN 0-662-00344-6 QSW 038324 STLCOPCB4022148 ABSTRACT A survey of polychlorinated biphenyls (PCB's) concentrations in the raw wastewaters from 33 municipalities was carried out. In addition, detailed investigations of the fate of PCB's during conventional secondary treatment were performed at the Hamilton Wastewater Treatment Plant. PCB concentrations in raw wastewaters ranged from less than 0.1 to 1.8 ppb, with the industrial areas of Hamilton, Toronto and Windsor exhibiting the highest levels. Only the 125^ and 1260 Aroclors were detected in any of the wastewaters. The primary treatment facilities surveyed removed, on the average, 50% of the PCB load, whereas the secondary plants averaged 66% removal. PCB concentrations in digested sludges ranged from 0.6 to 76.6 ppm (dry weight). PCB removal during wastewater treatment is largely by accumulation in the primary and/or waste activated sludge streams. There seemed to be little biodegradation. There are indications that multiple-hearth incineration may destroy the PCB's encountered in dewatered sludges. However, more experimental work is necessary to substantiate this observation.i i . DSW 038325 ___________ _________________ ____ STLCOPCB4022149 RESUME La concentrat ion des biphnyles polychlords (BPC) dans ies eaux usdes non trait^es de 33 villes a fait 1'objet d'une etude. De plus, une enqugte poussde sur ie sort de ces composes soumis au traitement secondaire ciassique s'est poursuivie 3 la station d'epuration de Hamilton. Leur concentration variait entre moins de 0,1 et 1,8 ppm, les plus forts taux 6tant enregistrs dans les regions industrie1les de Hamilton, Toronto et Windsor. Seuls les Aroclors 125^ et 1260 etaient presents dans toutes ies eaux non traites. En moyenne, les installations de traitement primaire observes ont dlimind 50 p. 100 des BPC et celles de traitement secondaire, 66 p. 100. La teneur en BPC des boues dig^rees se situait entre 0,6 et 76,6 ppm (poids des boues sechdes) . Pendant le traitement des eaux usAes, les BPC s'61iminent surtout en s'accumulant dans les depots de la decantation primaire ou dans les boues activdes rsiduaires. Au cours du traitement, la bio degradation a semble peu importante. II se pourrait, par ailleurs, que 11incingration dans des fours 3 soles multiples arrive A detruire les BPC presents dans les boues d6shydrates. Toutefois, il faudra poursuivre les experiences pour le confirmer. DSW 038326 STLCOPCB4022150 TABLE OF CONTENTS ABSTRACT TABLE OF CONTENTS List of Fiqures List of Tables CONCLUSIONS 1 BACKGROUND AND STUDY OBJECTIVES Page j; , v v; I 2 EXPERIMENTAL PROCEDURES 3 2.1 Study Sites and SamplingProcedures 3 2.2 Procedure for Detailed Sampling of the Hamilton Waste- 3 water Treatment Plant 2.3 Analytical Procedures 7 3 RESULTS AND DISCUSSION 3.,I PCB's Survey Results 3.2 Fate of PCB's Within a SecondaryTreatment Plant 8 8 10 BIBLIOGRAPHY ACKNOWLEDGEMENTS APPENDIX - METHODS FOR PCB ANALYSIS IN WASTEWATERS AND SLUDGES |$ 18 21 DSW 038327 iri STLCOPCB4022151 LIST OF FIGURES Location of Wastewater Treatment Plants Sampled During PCB's Survey Schematic Diagram of the Hamilton Wastewater Treatment Plant PCB's Transport Within the Hamilton Wastewater Treatment Plant Chromatograms for Aroclors ]2$k and 1260 and a Sewage Sludge Sample Page k 13 2k DSW 038328 iv STLCOPCB4022152 Table 1 2 3 4 5 LIST OF TABLES Design Data for the Hamilton Wastewater Treatment Plant [Design Flow = 60 mgd (273*000 m^/day)] Polychlorinated Biphenyls (PCB's) in Wastewaters and Sludges from Selected Ontario Municipalities (197*0 Estimated Influent and Effluent PCB's Loadings for Selected Ontario Municipalities Flows for Various Plant Streams During PCB's Sampling Total Solids Concentrations of Plant Streams During PCB's Samp ling Page 6 9 11 1 14 DSW 038329 v STLCOPCB4022153 CONCLUSIONS This report includes the results of a polychlorinated biphenyls (PCB's) survey conducted on 33 municipal wastewaters in Ontario. In addition, detailed investigations of the fate of PCB's within a conven tional secondary wastewater treatment plant are described. Conclusions arising from these studies are: (i) PCB's, exclusively the 125** and 1260 Aroclors, were detected in all municipal wastewaters sampled. Raw wastewater PCB levels ranged from less than 0.1 ppb to a high of 1.8 ppb. The primary treatment plants surveyed averaged 50% PCB removal, whereas the secondary plants averaged 66% PCB removal. It was estimated that the total PCB's receiving water load from the 33 plants was 2A6 kg/yr or 67 mg/capita/year. (ii) PCB's are accumulated in the sludge streams of the treatment plants. Digester sludge samples ranged from 0.6 to 76.6 ppm (dry weight). (iii) Industrial centres such as Toronto, Hamilton and Windsor had the highest PCB concentration in the raw wastewaters and, consequently, high concentrations in the sludges. (iv) PCB's, particularly the 125^ and 1260 Aroclors, degrade very little, if at all, during conventional secondary wastewater treatment. Removals are largely by physical separation with the primary sludges and accumulation in the activated sludge. (v) It appeared that PCB's might be destroyed when incinerated in a multiple-hearth incinerator. Further research, however, is necessary to determine the preferred method for disposing of high level PCB sludges. (vi) With the phasing out of PCB's and limitation to closed cycle uses in recent years, it is unlikely that any special treatment for their removal from municipal vi DSW 038330 STLCOPCB4022154 wastewaters will be required. However, because of their persistence, PCB's will continue to remain in the aquatic environment at detectable levels for some time. OSW 038331 v1 i STLCOPCB4022155 1 BACKGROUND ANO STUDY OBJECTIVES In 19^6, the chemical compounds polychlorinated biphenyls (PCB's) were first discovered in the environment, even though they had been commercially available and used in many applications since the early 19301s (Gustafson, 1970). Since this time, considerable research effort in several countries has been devoted to determining the extent of PCB distribution in the environment, and the toxicity to various species of life. For example, Savage et al (1973) studied the occurrence of PCB's in silage; Veith and Lee (1971) measured PCB concentrations in fish of the Milwaukee River; Carnes et al (1973) analyzed solid wastes for PCB content; Veith (1972) monitored PCB levels in the waters of Green Bay and numerous researchers have studied interrelated influences. A detailed review of the copious PCB-related literature is beyond the scope of this report. However, Gustafson (1970) and Risebrough et al (1968) give detailed summaries of the state of the problem. Two of the more recent papers on the subject are by Hutzinger et al (197*0 and Peakall (1975). PCB's have a high chemical stability and have been used in a number of industrial applications including transformer oils, capacitor dielectrics, hydraulic lubricants, plasticizers, printing inks and surface coatings, to name some. Recent concern about their persistence in the environment has limited usage in the past two or three years to essential applications, such as fire resistant hydraulic transformer and insulating condensers. The report of the Interdepartmental Task Force on PCB's (1972) identified the following sources of PCB pollution: (i) open burning or incineration of municipal and industrial solid wastes; (ii) vaporization of paints, coatings, plastics, etc.; (iii) accidental spills or improper waste disposal; and, (iv) municipal and industrial sewers and sewage sludge disposal. The latter source was considered to be the largest contributor and it was estimated that in 1972, 6,000 tons/year of PCB's were discharged to the environment in this way. Schmidt et al (1971) sampled nine sewage treatment plant outfalls in California and identified the PCB Aroclors 1252, 125** and 1260 at concentrations ranging from 0.2 to 96 ppb. A more recent study by Dube et al (197*0 reported PCB's in Wisconsin treatment plant effluents. They found Aroclor 125*1 present at DSW 038332 levels ranging from less than 0.05 to 2.8 ppb. Furthermore, detailed studies at one secondary treatment plant indicated that PCB removals through the plant were in the order of 70%. It could not be determined from the data whether this removal was by biological decomposition or physical separation by adsorption/entrapment on the primary and waste activated sludges. Oden (1968), in a survey of 100 Swedish treatment plant sludges, found that the median PCB concentration was 1 ppm, with 67% of the samples lying between O.k to 2 ppm. Liu and Chawla (1976) have also identified PCB's in the ppm range in sewage samples collected from several Ontario wastewater treatment plants. Since there was little information available on the extent of the PCB contributions from municipal wastewaters in the Lower Great Lakes, a study was initiated under the Canada-Ontario Agreement on Great Lakes Water Quality, with the following objectives: (i) to determine, by selected sampling of Ontario wastewater treatment plants, the concentrations of PCB's in raw and treated wastewaters and in primary, waste activated and digested sludges; and, (ii) to determine the fate of PCB's within a conventional activated sludge treatment plant. 2 DSW 038333 STLCOPCB4022157 2 EXPERIMENTAL PROCEDURES 2.1 Study Sites and Sampling Procedures Thirty-three wastewater treatment facilities at various locations (Figure 1 and Table 2) in the Lower Great Lakes were selected for PCB samp ling. The plants ranged in size from 0.1 mgd (455 m^/day) to 180 mgd (818,000 rn^/day) and included conventional activated sludge, primary and lagoon wastewater treatment systems. Sampling procedures at a particular plant involved hourly sampling of the influent and effluent and preparation of a flow-proportioned 24-hour composite sample; and sampling of other plant streams (i.e., primary sludge, waste activated sludge, digested sludge, digester supernatant and dewatered sludge cake, where applicable). Influent and effluent samples were collected with Isco automatic samplers. A sample tubing which did not cause PCB contamination was selected for the automatic samplers. Other plant streams were grab sampled twice during the day and a composite sample prepared. It became evident from early results that the PCB's were concentrated in the plant sludge streams; consequently, some of the latter plant sampling involved sludge samples only. All samples were collected in acetone washed glass bottles. Plant flows were recorded and total solids determinations carried out on al1 sludge samples. 2.2 Procedure for Detailed Sampling of the Hamilton Wastewater Treatment Plant A detailed sampling study was conducted at the Hamilton Wastewater Treatment Plant. This plant receives a relatively high loading of PCB's in the raw wastewater (thus facilitating PCB tracing through the plant), it is close to the Wastewater Technology Centre, treats a large volume of wastewater with accurate flow measurement in all major plant streams, and incorporates virtually all facets of conventional wastewater treatment and sludge disposal (including flotation, vacuum filtration and incineration). For these reasons, the Hamilton plant was selected and it was felt that the results would have general application to other plants having similar unit operations and processes. A schematic diagram of the Hamilton Wastewater Treatment Plant is shown in Figure 2. Design data for the individual plant components are summarized in Table 1. 3 DSW 038334 STLCOPCB4022158 STLCOPCB4022159 FIGURE 2. SCHEMATIC DIAGRAM OF THE HAMILTON WASTEWATER TREATMENT PLANT os w 038336 TABLE 1. DESIGN DATA FOR THE HAMILTON WASTEWATER TREATMENT PLANT [DESIGN FLOW = 60 mgd (273,000 m3/day)] COMPONENT Main Pumping Station Degritter Facilities Primary C1arifiers Aeration System Secondary Clarifiers Flotation of Waste Activated Sludge Digesters Vacuum Fi1tration 1 ncinera tors DETAILS - 78 ft (23.7m) deep x 40 ft (12.2m) d ia. - 5 pumps - A bar screens - 4 -35 ft (10.7m) dia. degritters - 8 tanks Retention Time 2.2 hrs Overflow Rate - 740 gpd/ft^ (36.2 m3/day`m2) - 8 tanks with mechanical aeration Retention Time - 6 hrs - 8 tanks Retention Time - 2.9 hrs ,, Overflow Rate - 520 gpd/ft (25.4 m3/daym2) - 4 units Total Surface Area - 1,600 ft2 (148.6 m2) - h primary, 4 secondary Total Volume - 14 MG (63,588 m3) Retention Time - 40 days - 4 Filters Total Area - 2,000 ft2 (185-8 m2) - 2 Multiple Hearth Units The PCB balance sampling was initiated on February 11 and continued until February 19, 197^** Mo samples were collected on February 16 and 17. The sampling locations are shown in Figure 2. Automatic samplers were set up to take hourly samples at locations 1 (influent) and 2 (effluent). Since it is very difficult to sample the raw sewage line at the Hamilton plant, the effluent from the wet well was sampled. This stream contains not only raw sewage but waste activated sludge, digester supernatant, flotation subnatant and vacuum filtrate which have been cycled back to the wet well. Corrections were made in subsequent calculations for the waste loading from the additional sources. Four flow proportioned composite samples were prepared from the hourly influent and effluent 6 DSw 03833? STLCOPCB4022161 samples for the periods 03 to 08, 09 to 14, 15 to 20, and 21 to 02 hours. Samples of primary sludge (location 3) were collected from each of the eight primary clarifiers at six-hour intervals and combined into one daily composite. Twice daily samples were collected for the mixed liquor (4), waste activated sludge (5), thickened waste activated sludge (6), and flotation unit subnatant (7). Digested sludge (8), filter cake (9), vacuum filter filtrate (10) and incinerator scrubber water stream (II) were sampled twice during each daily eight-hour sludge dewatering period. Digester supernatant (12) was sampled only when it was discharged to the wet well. The flow quantities of the various plant streams were recorded daily. 2.3 Analytical Procedures A detailed description of the procedures used for PCB analysis is presented in the Appendix to this report. In brief, the procedures consisted of extraction, clean-up and chromatographic separation steps and are similar to, or modifications of, methods previously developed by Chau (1972). Other analyses performed during the project were in accordance with Standard Methods (APHA et al, 1971). 7 OSW 038338 3 RESULTS AMD DISCUSSION 3.1 PCB'5 Survey Results The data collected during the wastewater treatment plant survey is presented in Table 2. The fact that PCB's were detected in all samples verifies the ubiquitous nature of polychlorinated biphenyls. PCB's were removed to various degrees through the treatment plants. The average removals for primary and secondary treatment plants were 502" and 66?,, respectively. Only Aroclors 125** and 1260 were detected in the wastewater and sludge samples. Thus, these same Aroclors must be the predominant PCB's used in industrial applications. At most treatment plants there appeared to be a mixture of the two Aroclors. Some samples demonstrated chromatograms which closely resembled one Aroclor or the other. For example, the samples from the Hamilton and Windsor Little River plants contained only 1260, whereas in the samples from New Hamburg, Preston and Windsor West plants, Aroclor 125** predomi na ted. Other i nves t i ga tors have found that Aroclors 125** and 1260 are predominant in wastewaters, although Dube et al (197**) identified Aroclor 1248 in a Wisconsin waste water and Schmidt et al (1971) found Aroclor 1242 in some California wastewaters. High PCB's concentrations in the sludge samples indicate that the removal mechanism is physical (i.e., solid liquid separation by settling). This finding is consistent with the low water solubility of PCB's. The concentration factors (i.e., ratio of influent concentration to primary sludge concentration) ranged from a low of 17.5:1 for the Windsor Little River plant to a high of 1,900:1 for the Toronto Highland Creek plant. The average concentration factor for all plants was 400:1. Dube et al (197**) reported similar concentration factor values for several Wisconsin wastewater treatment plants. Digested sludges contained relatively high PCB levels with the samples from Hamilton being by far the highest at 76.6 ppm (dry weight). All other digester sludges averaged 3.2 ppm. It was not unexpected to find that the various dewatered sludge cakes contained elevated PCB concentrations, with Hamilton again being the highest at 69.8 ppm. Estimates were made of the amounts of PCB's being: DSW 038339 STLCOPCB4022163 TABLE 2. POLYCHLORINATED BIPHENYLS (PCB's) IN WASTEWATERS AND SLUDGES FROM SELECTED ONTARIO MUNICIPALITIES (197^) LOCAT l Oil (see Figure 1) AVG. FLOW (MIGD) TREATMENT5 PROCESS INFLUENT EFFLUENT PRIMARY SLUDGE WASTE ACTIVATED SLUDGE MIXED LIQUOR PRIMARY DIGESTER SECONDARY DIGESTER SUPER NATANT SLUDGE5 CAKES AROCLCRS 1 9rant ford 2 Burlington 3 Chatham 4 E Hi ra ^ 5 Galt 6 Guelph 7 Grimsby 8 Marri 1 ton 9 Kingston City 10 Kingston TVP 11 Ki tchener 12 Lakeview 10.2 6.0 *i-5 0.5 5-5 7.5 0.2 52.0 II.9 0.9 12.0 16.0 13 London Greenway 1 U he- Hamburg 15 hewnarket 15 fi i ag,,-0n-7he- Lake2 17 Cakvl1le 13 Qsha-a 15 Cltawa-Greens Corn-rs 8.3 0.2 1.6 0.5 6.0 9-0 65.0 20 Ottawa - Watt Cr. 6.8 i Peterborough 9.0 22 Fort Dover 0.4 23 Preston 2. 2^ Sarnia 7.0 25 Toroto - Main 180.0 26 Toronto - Humber 63-0 27 Toronto " highland 23 Toror to - Horth 19-0 9.0 23 `waterdown 0. 35 Water loo 6.7 31 We 11 and 7.1 32 Windsor - West 24.0 33 Windsor - Little River 4.0 CAS EA CAS CAS CAS CAS L CAS P CAS CAS CAS CAS L CAS+PR L CAS P P CAS CAS P CAS P CAS CAS CAS CAS+PR CAS CAS P P*PR CAS 1.5 0.5 0.2 0.1 1.8 0.3 0.9 0.2 0.4 0.4 0.4 0.2 <0.t 0.3 1.0 0-9 0.3 0.5 0.6 <0. 1 <0.1 <0. 1 0.2 0.1 1.7 0.4 <0, l5 <0, ) 0.2 - <0.1 0.3 0.2 0.2 - <0.) <0, <0.1 <0. <0. 1 <0.1 <0.1 _ <0. 0-3 - 0.2 0.4 0.4 <0.1 <0.1 <0.1 <0. <0. 1 0.9 <0. 1 71 0.7)*1 57 0.5) 2900 (38.%) 100 (1.5) 230 (3-7) 647 (11.3) 114 (2.5) 23 32 (2.2) 140 (3.6) 74 (2.2) 13 (0.4) 112 (2.3) 83 0.4) 60 (1.6) 140 (4.1) 115 (2.5) 61 (1.3) 87 (2.4) 33 22 - 190 76 <?..o) 5 11 43 (0.9) 2500 (20.8) 7- 16 105 27 13 113 17 29 19 13 23 55 - - 9 24 - 23 - - 5 87 (2.4) - - - 1254 l 1260 * -- - - 1254 6 1260 - 69 (2.0) - - - 1254 16 - - - - 1254 ( 1260 5 6! (2.4) - - - 125-t 6 1260 - 740 (6.3) 230 (3.9) - - 1254 i 1260 - -- - - 1254 6700 (76.6) 850 13600 (69.6) i;s: - 630 (6.8) 120 I2S4 l 1260 --- 7 1900 (6.1) 1254 * 1260 15 180 (4.1) 332 - - 1254 s 1260 - 88a (10.6) - - 1254 6 1252- 15 - - - - 1254 i 1260 - -- - - 1254 S 59 (0.6) - 1 - 1254 6 1260 - -- - 8 101 (4.8) 100 (5.7) f - 103 0.6) 106 (1.2) 54 1254 t 1260 1254 6 1260 * I2S* * 1260 - 53 (3-D 23 (2.5) 31 ISO (2.7) 1254 t 1263 - 140 (5.3) 240 (5-5) 78 - 1254 t 1260 - 92 (4.6) - - * 1254 ( 1260 - 170 (2.7) - - - 1254 i 1260 3 -- - - 792 (4.9) 53 (2.5) 11 - 1254 * 1254 i 1260 7 123 0.5) 133 (30) 3 - 1254 6 1260 * 113 0.4) 240 (3.0) - `` 1254 t 12(0 15 363 (4.5) 263 (3.3) 433 3 67 (2.3) 80 (2.7) 60 - 37 (0.4) - - 5 52 (0.6) 53 (0.6) 3 - 38 (2.9) 105 (2.6) - --- - 3500 (11.8) 1254 12(0 1254 i 1260 1254 t 12(3 1254 l 1260 125* i 1260 125* - 48 (0.6) - -- 1260 STLCOPCB4022164 CAS Samples contained considerable pesticide residues Sludge cakes were from vacuum filters or sludge disposal lagoons Conventional Activated Sludge EA Extended Aeration l * Stabilization Pond P Pr rna ry Figures in parenthesis are dry weight concentration in ppm ** 0.1 ppb Limit of Derecrabi1ity OSW 038340 (i) received at wastewater treatment plants; and (ii) discharged to the receiving water, for the 33 survey sites. Calculations for 26 treatment plant analyses of influent and effluent PCB loadings per year are summarized in Table 3. The total PCB loading being received at the treatment plants was 56* kg/yr (l,2A3 Ib/yr), whereas the amount being discharged to the receiving waters was approximated as 2A6 kg/yr (5^2 lb/yr). The 26 plants had a sewered population totalling 3.66 million people. Therefore, the per capita PCB contributions for influents and effluents were 15^ and 67 mg/cap/yr, respectively. The larger and more heavily industrialized municipalities of Toronto, Hamilton, Ottawa and Windsor, accounting for 82% of the population, also accounted for 91% of the total PCB's load going to waste treatment facilities. The waste water and sludge concentration data in Table 2 verify the industrial influence factor. For example, strictly domestic municipalities such as Waterdown, Newmarket and Grimsby had low PCB levels in influents, effluents and sludges. The PCB's in these domestic wastewaters perhaps originated from storm water or household material that contain low amounts of PCB's. Some grab samples collected from the Guelph storm sewer system verified that PCB's are present in storm water discharges (i.e., average PCB content of the Guelph samples was 0.12 ppb). Veith and Lee (1970) found trace amounts of PCB's in some dishwasher detergents, aluminum foil and packa ging materials. Based on the estimates made in Table 3, it appears that about of the total PCB load received at treatment plants is eventually discharged to the receiving stream. The other 56% is probably accumulated in the sludges (there may be some slight biodegradation). This presents a potential sludge disposal problem which will be discussed in more detail later. The Monsanto Company, sole producer and supplier of PCB's in North America, has restricted the sale of PCB's to essential closed cycle uses in the past five years. As a result, the PCB loadings in wastewaters are likely to decrease in the future. However, the persistence of the material makes it a problem, particularly in land disposal of sludges. 3.2 Fate of PCB's Within a Secondary Treatment Plant A detailed seven day sampling program was carried out on various process streams of the Hamilton Wastewater Treatment Plant. The sampling 10 DSW 038341 1 STLCOPCB4022165 TABLE 3. ESTIMATED INFLUENT AND EFFLUENT PCB's LOADINGS FOR SELECTED ONTARIO MUNICIPALITIES LOCATION LOADING (kg/yr ,U2 ) INFLUENT EFFLUENT SEWERED3 POPULATION 2. BurlIngton 3. Chatham 4. Elmira 7- Gr1msby 8. Hami1 ton 9. Kingston City 11. Kltchener u. London - Greenway 14. New Hamburg 15. Newmarket 16. Nlagara-on-the-Lake 17. Oakvi1le 18. Oshawa 9. Ottawa - Greens Corners 21. Peterborough 22. Port Dover 24. Sarnia 25. Toronto - Main 26. Toronto - Humber 27. Toronto Highland 28. Toronto North 29. Waterdown 30. Waterloo 31. We 11 and 32. Windsor - West 33. Windsor - Little River 19.9 <1.3 (0.65)'' 67,000 3-3 <0.7 (0.35) 32,000 0.2 0.2 4,800 0.03 <0.03 (.015) 1,720 154.1 25.8 318,000 5-9 >7.9 2.7 3.9 4.0 <1.4 (0.70) 70,000 111,000 1 10,000 0.1 <0.03 (0.015) 3,000 1.1 <0.3 (0.15) 15,000 0.3 <0.1 (0.05) 3,500 2.0 <1 .0 (0.5) 25,000 <1.0 (0.5) <1.0 (0.5) 87,000 32.3 <30.7 (5-35) 358,000 14.9 <1.5 (0.75) 57,000 0.6 0.2 2,500 3.5 2.3 58,000 165.9 119.2 1,250,000 62.6 41-7 540,000 <3.1 (1.55) <3.1 (1.55) 200,000 <1.5 (0.75) <1.5 (0.75) <0.02 (0.01) <0.02 (0.01) 170,000 2,140 2.2 <1.1 (0-55) 40,000 1.2 <1.2 (0.60) 35,000 67.5 35.8 100,000 2.7 <0.7 (0.35) 60,000 TOTAL 563.7 246.2 3,660,360 Calculations Based on Flows and Concentration Data in Table 2 2 To Convert kg to lbs Multiply by 2.205 3 Water and Pollution Control Directory 1973-74 if Assumed Concentration was 50% of Detectability Limit 11 DSW 038342 STLCOPCB4022166 procedures were described in Section 2.2. The results of the study at the Hamilton plant are summarized in Figure 3. Averages and standard deviations for PCB levels measured at each sampling location are presented. In addition, the PCB mass transported via each stream has been calculated from flow and concentration data. Because the sampling period was rela tively short and no attempt was made to account for storage changes in the various units, the results presented in Figure 3 should not be interpreted in a mass balance sense. However, the data demonstrate the relative fate of PCB's within a conventional secondary treatment system. Average flow and total solids data are summarized in Tables 4 and 5, respectively. Based on the seven day influent and effluent loading, the treatment plant removed 87% of the PCB material received. Of the total influent loading of 3-92 kg (including digester supernatant, vacuum filtrate and flotation subnatant) , 31% or 1.21 kg was removed in the primary sludge and transported to the digesters via the thickened waste activated sludge. . Waste activated sludge returned to the wet well recycled 1.93 kg. Appro ximately 45% or 1.77 kg could not be accounted for. The reasons for this are probably: (1) accumulation within the system; (2) sampling which was not sufficiently sensitive to pick up some large PCB fluctuations or biological decomposition. Analysis of heavy metal (Cr, Zn, Ni, Cu and Pb) data collected at the Hamilton Wastewater Treatment Plant during the period of the PCB survey showed that, within the system, the heavy metal accumulation pattern was similar to that of the PCB's. This suggests that the plant was not at steady state and the PCB loss probably cannot be attributed to degradation. Lack of steady state operation is also apparent in the digestion system. Here, during the seven day period 1.74 kg of PCB's were added, 13-6 kg were withdrawn for sludge dewatering and supernatant return. Over an extended time period, the PCB input/output to the digesters should balance. The amount of PCB's stored in the four digesters was calculated to be 212 kg (469 lb). This represents a large reservoir of PCB's, equivalent to 450 days of PCB influent loading. Essentially all of the PCB's remained in the sludge solids throughout the flotation thickening of the waste activated sludge (i.e., 0,0006 kg (0.0013 lb) in the subnatant and 0.53 kg (1.17 lb) in the 12 DSW 038343 STLCOPCB4022167 INFLUENT KEY A = AUG. CONCENTRATION (ppb) B = STANDARO DEVIATION (ppb) C = AUG. DAILY LOADING (Kg) D = TOTAL SEVEN DAY LOADING (Kg) TO CONVERT Kg TO lbs MULTIPLY BY 2 205 FIGURE 3.PCBS TRANSPORT WITHIN THE HAMILTON WASTEWATER TREATMENT PLANT DSW 038344 TABLE 4. FLOWS FOR VARIOUS PLANT STREAMS DURING PCB's SAMPLING STREAM AVERAGE FLOW (mgd) STANDARD DEVIATION Influent & Effluent Primary Sludge Waste Activated Sludge Thickened Sludge Digester Supernatant Flotation Subnatant Digester Sludge to Vacuum Fi1ters Sludge Cake Vacuum Filtrate Incinerator Scrubber Water 56.0 (2629)1 0.0595 0.4813 (3.12) (25-3) 0.0382 (2.01) 0.0184 (0.97) one day on 1 y 0.1148 (6.04) 0.0627 (3.30) 119.2 Ton s 0.0393 (2.06) 0.252 (13.26) 6.6 0.0115 0.1168 0.0105 (3.10) (0.61) (6.14) (0.55) 0.0529 (2.78) 0.0079 31.6 Tons 0.0055 (0.42) (0.29) 0.053 (2.79) ^Values - Parenthesis are I/sec TABLE 5. TOTAL SOLIDS CONCENTRATIONS OF PLANT STREAMS DURING PCB's SAMPLING STREAM Primary Sludge Waste Activated Sludge Thickened Sludge Mixed Liquor Digested Sludge Sludge Cake Vacuum Fi1trate Supernatant Incinerator Scrubber Water AVERAGE TOTAL SOLIDS {%) STANDARD DEVIATION 5.75 1 .53 5.64 3240 mg/) 8.69 19.50 3475 mg/1 2.18 (one day only) 1210 mg/1 0.44 0.10 O.85 585 mg/1 2.02 1.16 1250 mg/1 -- 290 mg/1 DSW 038345 14 STLCOPCB4022169 thickened sludge). Losses to the filtrate in the vacuum dewatering of the digested sludges were relatively high at 0.51 kg (1.12 lb). This was consistent with high solids content of the filtrate (i.e., 3,475 mg/1 in Table 5)- About 25% of the PCB load applied to the vacuum filter as digested sludge could not be accounted for the in the sludge cake plus filtrate. It is suspected that this discrepancy was most likely due to insensitive sampling procedures. In this regard, note in Figure 3 the large standard deviations of the PCB concentration in the digested sludge, sludge cake and filtrate samples. Ninety-nine percent of the PCB load applied to the multiplehearth incinerators was lost during incineration (i.e., 9.66 kg fed in the sludge cake and 0.08 kg remaining in the scrubber water and ash). Two loss mechanisms were possible: (i) combustion and destruction of the PCB's; or, (ii) volatilization and transport to the atmosphere. It has been reported (Anon, 1973) that a multiple-hearth furnace operating at 815 to 925C (1,500 to 1,700F) and an exhaust temperature of 590C (1,100F) is capable of 99-9% destruction of PCB residuals in sewage sludge. Lowering exhaust temperatures to 425C (800F) results in a slightly lower destruction of PCB's to 94%. Since the Hamilton incinera tors were generally operated between 815 to 925C with exhaust temperatures of 370 to 425C, it is possible that the PCB losses were due to combustion. However, the fact that PCB's were detected in the scrubber water suggested some material was being volatilized. It is suggested that further research should be undertaken on this aspect of PCB's in sewage treatment plants, with appropriate analyses of the stack gases. 15 DSW 038346 REFERENCES Anon "Sludge Furnace Eliminates PCB Residual", Water and Sewage Works, 120 (9): 88 (1973). APHA, AWWA, WPCF, Standard Methods for the Examination of Water and Wastewater, 13th Edition (1971). Carnes, R.A., J.U. Doerger and H.L. Sparks, "Polychlorinated Biphenyls in Solid Waste and Solid Waste-Related Materials", Archives of Environmental Contamination and Toxicology 1 (1): 27 (1973). Chau, A.S.Y., "Analyses of Chlorinated Hydrocarbon Pesticides in Waters and Wastewaters", Department of the Environment, CCIW, Bur 1ington (1972). Dube, D.J., G.D. Veith and F.G. Lee, "Polychlorinated Biphenyls in Treatment Plant Effluents", Journal WPCF, *46 (5): 966 (197**). Gustafson, C.G., "PCB's - Prevalent and Persistent", Environmental Science and Technology *4:81*4 (1970). Hutzinger, 0., S. Safe and V. Zit:ko, "The Chemistry of PCB's" CRC Press, Cleveland, Ohio (197*0. Interdepartmental Task Force on PCB's, "Polychlorinated Biphenyls and the Environment", National Technical Information Service, COM-72-10*419, Springfield, Virginia 22151 (1972). Liu, D. and V.K. Chawla, "Polychlorinated Biphenyl (PCB) in Sewage Sludges", 10th Annual Conference on Trace Substances in Environmental Health, University of Missouri, June, 1976. Oden, S., "Heavy Metals and Chlorinated Hydrocarbons in Sludge", Grundfforbattring 23 (5):55 (1968). Peakall, O.B., "PCB's and their Environmental Effects", CRC Press Cleveland, Ohio (1975)Risebrough, R.W., P. Rieche, D.B. Peakall, S.G. Herman and M.N. Kirven, "Polychlorinated Biphenyls in the Global Ecosystem", Nature 220:1098 (1968). DSW 038347 16 STLCOPCB4022171 13, Savage, E.P., J.D. Tessari and B.S. Malberg, "The Occurrence of PCB's in Silage Stored in Pit and Upright Silos", Bulletin of Environmental Contamination and Toxicology 10 (Z):97 (1973). \k. Schmidt, T.T., R.W. Risebrough and F. Gress, "Input of Poly chlorinated Biphenyls into California Coastal Waters from Urban Sewage Outfalls", Bulletin of Environmental Contamination and Toxicology 6 (3):235 (1971). 15. Veith, G.D., "Recent Fluctuations of Chlorobipheny1s (PCB's) in the Green Bay, Wisconsin, Region", Environmental Health Perspect ives, pp 51 ApriI (1972). 16. Veith, G.D. and G.F. Lee, "Unpublished Data", Water Chemistry Program, University of Wisconsin, Madison (1970). 17. Veith, G.D. and G.F. Lee, "Chiorobipheny 1 s (PCB's) in the Milwaukee River", Water Research 5:1107 (1371)- 17 DSW 038348 STLCOPCB4022172 ACKNOWLEDGEMENTS The authors wish to acknowledge the advice and analytical support provided by Mr. A.S.Y. Chau, Head, Special Services Section, Water Quality Laboratory and Network, Canada Centre for Inland Waters. Gratitude is expressed to the various plant operators who cooperated in the sampling programs carried out at their plants. Particular mention is made of Mr. Neil Gross, Superintendent of the Hamilton Wastewater Treatment Plant who provided excellent cooperation. Thanks is expressed to Messrs. G. Huber and D. Vachon, who carried out aspects of the sampling program. CSW 038349 18 STLCOPCB4022173 APPENDIX METHODS FOR PCB ANALYSIS IN WASTEWATERS AND SLUDGES DSW 038350 STLCOPCB4022174 APPENDIX METHODS FOR PCB ANALYSIS IN WASTEWATERS AND SLUDGES A.I Method I This method is used for samples having a high proportion of sol ids, such as sludges, supernatants, and mixed liquors. For samples with a low solid content, see Method 2. (i) Samples are well shaken before extraction to ensure homo geneity. Amounts of sample used for extraction are as follows: -- sludge cakes -- digester and raw sludges supernatants and mixed 1 i quors 25 g 50 ml 150 ml Samples are mixed with 300 ml acetonitrile and 10 ml cone. H2S0^ in a Waring blender with a Bakelite top and blended at the highest possible speed without spilling for one-half hour. (iii) Samples are allowed to settle. Liquid is decanted off, and remaining solid is mixed with 100 ml more acetonitrile and blended for one-half hour more. This step is repeated once more. (iv) After decantation of the liquid phase, the solid phase is filtered through a 1/2" layer of Celite that has been prewashed with acetone and then washed with acetonitrile. (v) All filtered and decanted liquids are combined and distilled deionized water is added to make a 50:50 water acetonitrile solution. (vi) This solution is partitioned with petroleum ether in a separatory funnel (two-litre) three times with 150 ml, 90 ml and 60 ml of petroleum ether, respectively. (vii) Aqueous layer is discarded and petroleum ether layers are combined and shaken with 200 ml distilled water in the separatory funnel to ensure complete removal of acetonitrile from the petroleum ether solution. DSW 038351 _ STLCOPCB4022175 (vi i i) (ix> (x) (xi) (xii) The water layer is discarded and the petroleum ether layer is dried by filtering through a 2" layer of anhydrous Na $0. (See 4H equipment list). Rinse the layer with approximately 25 to 50 ml petroleum ether. All flasks are washed with petroleum ether and the washings are added to the filtered solution through the Na^SO^ fiIter. The petroleum ether solution is evaporated to approximately 2 ml on a Rotavap, on a water bath not exceeding kOC to avoid possible loss of PCB's. A liquid chromatographic separation column is set up as follows: - the column used is a 20 mm x ^00 mm Pyrex column with a fritted glass disc and a Teflon stopcock at the bottom. A 1/2" layer of anhydrous t^SO^ is placed on the bottom of the column; 30 g of activated Florisil^ (see equipment list) are wet-packed in hexane above the Na^SO^ layer, and then another 1/2" layer of anhydrous Na^SO^ is placed on the Florisil layer. The column is washed with 200 ml of hexane and the liquid drawn off to the upper level of the ^50^. A clean receiving flask (500 ml round-bottom) is placed under the top of the column. For further details regarding the preparation of a chromatographic column see Chau (1972). Quantitively transfer the petroleum ether extract to the column. Allow the extract to sink just to the surface of the Na,,S0, layer by opening the stopcock. Wash the flask with 3 ml hexane and transfer the washings to the column. Allow the liquid to sink down as before. Repeat twice with 3 ml hexane. Elute the column with 200 ml hexane, catching the eluate in a clean 500 ml round-bottom flask. Elution rate should be about 5 ml/min. For further details regarding elution on a Florisil column consult Chau (1972). Evaporate the eluate to 2 ml on the Rotavap. Dilute the eluate to 10.0 ml in benzene in a graduated centrifuge tube or a volu metric flask. Use the extra 8 ml of benzene to rinse the elute flask after transferring the eluate to the graduated centrifuge DSW 038352 STLCOPCB4022176 (xiii) (xiv) tube. Transfer 2 ml of the benzene solution to a clean, dry centrifuge tube, and add 0.05 ml of mercury (triple-distilled). Stopper the tube tightly with a glass stopper and shake vigorously. If the mercury turns into a black solid (Hg S), then transfer the solution to a new clean, dry centrifuge tube, add another drop of mercury and repeat. Repeat this procedure until no change in the mercury is seen. This procedure removes sulphur residues from the solution as they may cause a large interference on the gas chromatograph. Inject a suitable volume of the mercury-treated solution onto the gas chromatograph. The column and column conditions are the same as for organo-chlorine pesticide analysis (Chau, 1972). Standards used are Aroclor 125** and Aroclor ]260 (both 300 pg/ pi). Further dilutions of the samples to achieve on-scale read ings on the chromatograph are often necessary, especially for the digester and filtered sludges. Calculation of the concentration of PCB's in the sample is described in the following. A. 1 .1 (a) (b) Calculation of PCB Concentrations Aroclor 125** : The last three peaks corresponding to the retent ion time of DDD and DDT are used for calculation. Additional peaks are used if the results calculated from each of these peaks are too diverse. All results are averaged for reporting (four very small peaks appear after these peaks on the chromatograph, but are too small to be useful). A chromatogram for 125** is shown in Figure A.l. Using peak (3) for the arbitrary relative retention time of 1.00, the other two peaks used for analysis appear at relative retention times of 0.72 and 0.8**, respectively. Aroclor 1260: A chromatogram for 1260 is also presented in Figure A.l. The peaks used for analysis (called, 3, *4, 5, 6, 7> and 8) appear at these retention times: peak (3) peak (*t) : 1.0 0.8** peak (5) peak (6) : 1.10 : 1.30 23 CSW 038353 STLCOPCB4022177 AROCLOR 1260 8.0(4.! (300pg/|4l) N) -t- AROCLOR 1254 8.0(41 (300 pg/(4l) 12 ? PRIMARY SLUDGE FROM NEWMARKET STP AROCLOR (1254 + 1260 ) = 13 ppb a - vJ' JP FIGURE A 1 CHROMATOGRAMS FOR AROCLORS 1254 AND 1260 AND A SEWAGE SLUDGE SAMPLE peak (7) 1 .60 peak (8) 1.93 (c) The formula used for calculating the concentration of PCB's in the individual GC peaks is: \ (h sam) (v std) (cone std) .... . _ . PCB (ppb) = 7(-hr--st--dr)y x (Tv~---s--a--m--)V x 7(---w----s--a--m--p----r)- x (V) x (dilution factor) where: h sam = peak height of the sample h std = peak height of the standard v std =injection volume of the standard v sam =injection volume of the sample cone std = concentration of the standard w sam =weight of the sample used for extraction in g or volume of the sample used for extraction in ml V = volume of sample extract in ml (before mercury treatment) dilution factor = amount of dilution used for sample after mercury treatments in order to achieve on-scale readings. (d) The PCB concentration is reported as total Aroclor 1254 and 1260 In the case of Aroclor 1260 predominant, the peaks unique to 1260 are used and reported as such. The lowest level that can be calculated is 0.1 ppb of PCB. A.2 Method 2 This method is used for samples having a low proportion of solids, such as influents, effluents, subnatants, incinerator washes and filtrates. (i) Samples are well shaken before extraction to ensure homogeneity. The amount of sample used for the extraction is 400 ml. (ii) Samples are mixed with 30 ml hexane in a Florence flask (500 ml) and stirred for one hour at high speed with a magnetic stirrer (Teflon coated). 25 OSW 038355 STLCOPCB4022179 (iii) (iv) Samples are allowed to settle. Then they are poured into a 1litre separatory funnel and 150 ml petroleum ether is added. The samples are well shaken and allowed to settle. The aqueous layer is repartitioned with 90 ml petroleum ether. The petrol eum ether extracts are combined and filtered through a 2" layer of anhydrous Na^SO^ to remove water and break up the emul sion. Rinse the ^2^0^ well with petroleum ether and add the rinsing to the petroleum ether extracts. Follow Method 1 from step (ix) onwards, except that the evaporated eluate from the Florisil column should be diluted to 3-0 ml in benzene instead of 10.0 ml. A.3 A.3- I Equipment Required for PCB Analysis 1 gas chromatograph, set up for organo-chlorine pesticide analysis I Rotovap and water bath 1 Waring blender and Bakelite top 1 magnetic stirrer 1 10 pi injection needle Glassware 1 2-1itre beaker 1 2-1itre Erlenmeyer flask 1 2-litre separatory funnel l 1-litre separatory funnel I A11ihn funne1 1 500 ml Florence flask 2 round-bottom 500 ml flasks 1 20 x 400 chromatographic column (Teflon stopcock and fritted glass disc) 2 500 ml graduated cylinders 1 100 ml graduated cylinder 1 10 ml graduated cylinder 15 ml graduated centrifuge tubes 2 10 ml volumetric flasks 4 Pyrex wash bottles disposable Pasteur pipettes 26 DSw 038356 STLCOPCB4022180 Note: Glassware must be washed with soap and hot water, dried and rinsed with washing acetone, pesticide grade acetone and the solvent that will be used in the extraction glassware. The injection needle must be rinsed at least ten times with benzene between each injection, and periodically should be thoroughly washed with acetone, hexane and benzene. The glassware listed above is all that is necessary for analysis of a single PCB sewage sample. For routine analysis of a large number of samples, more equipment will be needed. Samples are normally analysed in pairs, in a staggered procedure, so that at any point in the analysis, the analyst is actually working on 8 to 12 samples at different stages of analysis. A.32 Solvents and Chemicals Note: All solvents must be pesticide grade, except for washing acetone. All glassware must be rinsed with pesticide grade solvents of suitable polarity before use. - washing acetone (technical grade) - acetone - hexane - petroleum ether - benzene - acetonitrile - methylene chloride - celite (Johns-Manvi1le) - anhydrous' Na,,S0, 2 - FI orisi1 L4 - concentrated H^SO^ - distilled deionized water - triple-distilled mercury - Aroclor 125^ (Monsanto Company) - Aroclor 1260 (Monsanto Company) DSW 038357 27 STLCOPCB4022181 Mia* Anhydrous ^^SO^. Commercial anhydrous Na^SO^ must be treated in the following way before use: (a) Rinse 500 ml of commercial anhydrous Na^SO^ with 900 ml acetone, then 600 ml methylene chloride, then 300 ml hexane, under vacuum. (b) Dry in a 125C oven at least overnight. Store in a desiccator. o Floris i 1 : use: # Commercial Florisil must be treated in the following way before -- Place a 2" layer of Florisil in an open 2-litre wide-mouth jar and dry in a 125C oven for 26 hours. Store in a desiccator, covered. 28 DSW 038358 STLCOPCB4022182