Document r3ZDj7vXQg9pB7VVxrZq1o8a
Wdliam R. Bradley and Associates
ENVIRONMENTAL HEALTH CONSULTANTS tS GREEN STREET NEWARK, N. 07102
2 0 1 622 - 4246
January 23, 1967
Sprayed Mineral Fiber Manufacturers Association, Suite 2300 One Wall Street New York, New York 1000S
Inc.
Attention: Technical Committee
Re: aJVIRONMBNTAL HEALTH INVESTIGATION
An environmental health study was made for the Sprayed Mineral Fiber Manufacturers Association, Incorporated on January 12, 1967, at the United States Mineral Products Com pany in Stanhope, Mew Jersey, in quarters provided for this study. Products of four companies were sprayed under con trolled conditions of application during which tests of air samples were collected in the breathing zone area of the spray operator. These air samples were submitted to micro scopic examination and dust count using the approved tech nique for the determination of respirable sl2e particles in the work environment. The dust counts involved particles 5 microns or less in diameter.
2- -
thm tests were conducted in a large open area with one side of the building opened directly to the outdoors* The sample collection point was at ail times two to three feet of the operators nose. 'The operator sprayed part of the time oh the ceiling and part of the time on the wall during each test. He held the spray nozzle in his hand and applied the products at a distance of three to five feet from the ceiling or wall. A large pedistal fan was turned on to ven tilate the test area between each test. Material applied during one test was removed from the wall between each test* Material applied to the ceiling felled by gravity during the tests which gave representative conditions of application.
The same personnel conducted all of the product feed to the blower and performed the spray application. The first twelve tests were conducted for ten minute periods each and the second series of twelve tests were conducted for five minute periods each. During the first twelve tests the UniAir type gun with sixteen holes was used. During the second twelve tests the Uni-Jet, airless type gun was used. With each type of spray gun the four products were spray tested under water flow rates of 7-*s pounds per minute, 10 pounds per minute and 12pounds per minute. These water flow rates were used with both types of application guns.
-3-
The fiber feed rate for all testa was designed for ten
pounds per minute. Actual fiber feed rates as supplied by
the blower hopper operator were as follows:
USMP
10 to 11.4 pounds per minute
a eh
7 to 8 pounds per minute
S&K
8 to 10 pounds per minute
Asb.
13. 6 to IS pounds per minute
The results of dust samples are as follows:
Dust Sample Analysis
United States Mineral Products Co. (USMP) Cafco Blase-Shield Type D
Baldwln-Ehret-aill, Inc. (BBS) Pyrospray Type 1
Smith & Kanzler (S&K) Spraycraft 1132 Type S
Asbestospray Corporation (Asb.) Asbestospray Type T
-4-
------------------------------------water Flow
,eat
(ibe-/
So. Product -mlnnte)
TOPS GPS_________ Killians of Uni-Air Uni-Jet Particles per 16 holes Airless-------Cable Foot of Mr
.1 USMF
2. BEH
3. S&X
4. Asb.
7.5 7.5 7.5 7.5
X X X X
13 18
21
14
5. USHP 6. BEH 7. S&K 8. Asb.
10 10 10 10
X X X X
11 17 22 12
9. 10. 11. 12.
USHP BEH S&K Asb.
12.5 12.S 12.5 12. S
X X X X
9
12
14 7
13. 14. 15. 16.
17. 18. 19. 20.
21. 22. 23. 24.
USHP BEH S&K Asb.
USHP BEH S&K Asb.
USHP
bsh
S&K Asb.
7.5 7.5 7.5 7.5
10 10 10 10
12.5 12.5 12.5 12.5
X 14 X 19 X 23 X 15
X 13 X 19 X 22 X 14
X 12 X 16 X 21 X 11
-5-
Snrnmary
Results of dust studies made on 4 mineral fiber products sprayed under controlled.environmental conditions shows that the spray operator would be exposed to the inhllatlon of as bestos fibers and other mineral wool dusts that might lead to occupational illness. The threshold limit values for as bestos fiber dusts is 5 million particles per cubic foot of air. It is considered that exposure to asbestos dust in concentration less than 5 million figure will not lead to the formation of asbestosls. Asbestosis is more likely to occur after long continued inhilation of asbestos dusts in high concentration such as may exist in a mining, milling or cutting of asbestos.
All test results were determined to be in excess of the 5 million particles per cubic foot threshold limit value. It is apparent that product application was more dusty when using the Uni-Jet (airless) type gun then when using the air supplied gun. It was also apparent that there was less airbom dust as the water flow rate increased. Products labeled USMP and Asb. were found to be about equal in dustiness as applied. It is noted that more Asb. fiber was applied per
6- -
rainute than USM application rata. It is noted that S&K fiber is most dusty with product BEH being slightly less dusty in all cases, but considerably mere dusty than USMP and Asb. products.
WRB/dm