Document r1qB78rGeNEMgQ5gDD2KxJvJ

rn- to mCC 5091C Monsanto pto*(n*m(ilocation) r. j. Hammann - Texas City, LP&S, 0-22 (Ext. 3234) PLAINTIFF'S EXHIBIT MON-1937 JAT! JUJ*CT wettNCt TO August 23, 1984 3rd Quarter Safety & Housekeeping Inspection - HCN Complex : G. W. Bryan 19D CC . SHAC J. E. Jennings 19D M. J. Sweeney 19D A. H. Conrad 0-5 J. G. Trafton 0-6 R. A. Forsthoffer 0-5 Bob Bohmler SS-9 Dan Nelson 33D The 3rd Quarter Safety & Housekeeping Inspection for the HCN Complex was conducted by the inspection team of Ray Forsthoffer, Bob Bohmler, Dan Nelson and Bob Hammann on August 13. The unit was given a qualified "good" rating. The reason for this rating was the shutdown work in progress. The following items need to be corrected: Safety 1. Recommend making safety procedures more visible (presently in cabinet). 2. Training manual was lagging in some areas. 3. Some old papers and signs on bulletin board - update? 4. Numerous hose inspections not up-to-date. 5. Safety chains missing from a few chain operators in rack - storage area. 6. HCN storage area: a) Other items stored with acid in bottom shelf of cabinet. b) Nitrogen hoses are tripping hazard at safety shower and eyebath south of TIO's. c) Half of a Dept. 51 extension ladder is by the emergency generator. This ladder is damaged and needs to be destroyed. 7. Hose at safety shower/eyebath location, north side of AN shack is a tripping hazard. 8. Men were working on the north end of 27T1 without a scaffold. 9. CT2: a) Inspection ports need to be repaired on shrouds at CT2-7.-3, and -4. b) Shroud retainer ring broken on CT2-5 - also need to check all other retainer rings due to corrosion on bolt assembly. c) Electrical plug roped to railing between CT2-1 and 2 on east side. SC 000546 LAM001744 3rd Quarter Safety & Housekeeping Inspection - HCN Complex Page 2. d) Sign on entrance to stairway on south stairs is broken. e) Chlorine line below block valve at chlorinator looks to be in poor condition. Housekeeping 1. Trash in and around extinguisher cabinet No. 8 by 25T12-2 dike wall. 2. Trash in T10-4 pit and on catwalk south of T10-2. 3. Need general cleanup of the TBA-LN storage tank pits. 4. Buckets, mop and various and sundry trash in CT2 breaker room. 5. Remove old refrigerator from kitchen area. 6. Maintenance work area needs straightening up. 7. Scaffold along side D101 should be removed. 8. Trash around 972T2-5 & 6. Please respond to this inspection in writing to J. G. Trafton with a copy to Steve Moncla by 9/7/84. /dgb R. T. Hammann SC 000547 LAM001745