Document qxpZZEXmMX7aBo7nG95zZoVM

To: Distribution Interoffice Communication From: Date: Subject: J. A Bodron December 4, 1989 1939 ANNUAL VCM SURVEY The 1989 Annual VCM Survey has been completed. This survey was used by Maintenance to locate and repair the listed VCM leaks and to determine fugitive VCM emissions. Attached is a list of the VCM leaks found in the 1989 survey. The 1989 survey located a total of 20 leaks and was conducted during the week of October 9 in the New Module and the VCM Tank Farm, and during the week of July 17 in the Old Module. During the week of October 16, all leaks found in the New Module and the VCM Tank Farm were repaired. The two leaks found in the Old Module were repaired the week of July 24. J. A. Bodron Co-op Process Engineer Co-op Process Engineer /tjs cc: RWS, DCS, PJK, BLT, JVU, CJMc, DFJ, RtfN, SCH, DAM FGJ, JBA, KWB A! BM 4 T VAB.0001217526 T ANNUAL VCM 1989 SURVEY I. NEW MODULE LEAK TYPE PPM 001 V(L) 500 002 003 004 005 006 007 V(L) V(V) F(V) F(V) F(V) F(V) 800 700 60 200 150 200, 006 F( V) 500 009 010 F( V) F( V) 80 70 Oil V(V) 100 LOCATION East RVCM Charge Pump, pressure gauge fitting on bleeder valve RVCM Filter PAK, FL-719, Valve on top Reactor 741, Shell level. Bleeder Valve #572 Reactor 742, Shell level, Condensor Bolt 'Reactor 742, Shell level, Condensor Bolt Reactor 741, Condensor level. Flange on top Reactor 741, Condensor level, Condensor Bolt Be twe e n #14- #6 Reactor 741, Condensor level, Condensor Bolt Between #35- #27 Reactor 741, Condensor k Reactor 742, Condensor Flange i Reactor 745, Condensor Control Valve level, level. \ level. Condensor Bolt #37 Bottom North Side, Bottom, North Side A II. VCM TANK FARM LEAK TYPE PPM LOCATION 101 V(L) 500 Sphere VCM Transfer Pump, PP-219, Pressure gauge on Bleeder Valve 102 F(L) 50 Sphere VCM Transfer Pump, PP-270, Flange on Bleeder valve located oust east of pump 103 F(L) 50 South VCM Unload Station, East side. South of connection platform. Valve closest to platform on connect hose 104 F(L) 50 Middle South VCM Unload Stat ion, East side. South of connection platform, Valve closest to platform on connect hose 105 F(L) 500 Middle North VCM Unload Station, West side, Inside manway on railcar. Temporary connection. North side of manway * VAB.0001217527 106 F(L) 500 107 F(L) 50 III. OLD MODULE LEAK 201 202 TYPE * V(L) V(V) PPM I .Middle North VCM Unload Station, West side. Inside manway on railcar. Temporary screw vonnrction, West side of manway North VCM Unloading Station, West side Inside manway on railcar. Plug, South side of manway , t LOCATION East of VCM Receivers, Filter, Bleeder Valve Reactor 500, Actuated Valve for Evacuation Line I VAB.0001217528